Guimaraes GJ, Saad JG, Annavarapu V, Bartlett MG. Mobile Phase Aging and Its Impact on Electrospray Ionization of Oligonucleotides. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:2691-2699. [PMID: 37978939 DOI: 10.1021/jasms.3c00264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
Abstract
The implementation of fluoroalcohol/alkylamine mobile phase systems in oligonucleotide LC-MS provides a good balance between chromatographic separations and MS sensitivity. Since its introduction, several parameters including mobile phase composition, additive concentration, alkylamine hydrophobicity, and different fluoroalcohols have been carefully evaluated and optimized. While our understanding of this mobile phase system has increased over the years, there are challenges that continue to hinder method performance and remain poorly understood. One of these challenges is the constant loss of MS sensitivity over time, commonly termed mobile phase aging. This study investigates two aging mechanisms associated with loss of MS sensitivity: alkylamine oxidation and aggregate formation. The relationship between pH, organic solvent, oxygen, and mobile phase aging is characterized, and mitigation strategies to extend mobile phase lifetime are discussed.
Collapse
Affiliation(s)
- Guilherme J Guimaraes
- Department of Pharmaceutical and Biomedical Sciences, University of Georgia College of Pharmacy, Athens, Georgia 30602, United States
| | - Jack G Saad
- Micromeritics Instrument Company, 4356 Communications Drive, Norcross, Georgia 30093, United States
| | - Vidya Annavarapu
- Department of Pharmaceutical and Biomedical Sciences, University of Georgia College of Pharmacy, Athens, Georgia 30602, United States
| | - Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, University of Georgia College of Pharmacy, Athens, Georgia 30602, United States
| |
Collapse
|
2
|
Crittenden CM, Lanzillotti MB, Chen B. Top-Down Mass Spectrometry of Synthetic Single Guide Ribonucleic Acids Enabled by Facile Sample Clean-Up. Anal Chem 2023; 95:3180-3186. [PMID: 36606446 DOI: 10.1021/acs.analchem.2c03030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
In recent years, CRISPR-Cas9 genome editing has become an important technology in biomedical research and has demonstrated tremendous therapeutic potential. With Cas9 endonuclease, the use of single guide ribonucleic acids (sgRNAs) allows for sequence-specific cutting on target double-stranded deoxyribonucleic acids. Therefore, the design and quality of sgRNAs can greatly affect the efficiency and specificity of genome editing. Mass spectrometry (MS) has been a powerful tool to detect molecular features and sequence a variety of biomolecules; however, as the sizes of oligonucleotides get larger, it becomes more challenging to desalt samples and achieve high-quality intact spectra with effective fragmentation. Here, we develop a simple but effective online column-based clean-up method (reversed-phase column in a size exclusion mode) that removes formulation salts and metal adducts from larger oligonucleotides upon entering the mass spectrometer in a consistent manner. Using the top-down approach without any nuclease digestion, we characterized and sequenced 100-nucleotide-long sgRNAs by higher-energy collision dissociation (HCD), collision-induced dissociation (CID), ultraviolet photodissociation (UVPD), and activated electron photodetachment (a-EPD). In a single 10 min liquid chromatography-tandem MS (LC-MS/MS) run, CID yielded the best sequence coverage, of 67%. When adding complementary UVPD and a-EPD runs, we achieved 80% overall sequence coverage and 100% cleavages for the variable sequence, the first 20 nucleotides from the 5' end. This LC-MS/MS platform provides a facile top-down workflow to analyze and sequence larger chemically modified oligonucleotides with no sample treatment.
Collapse
Affiliation(s)
- Christopher M Crittenden
- Small Molecule Analytical Chemistry, Genentech Inc., South San Francisco, California 94080, United States
| | | | - Bifan Chen
- Small Molecule Analytical Chemistry, Genentech Inc., South San Francisco, California 94080, United States
| |
Collapse
|
3
|
Caleb Bagley M, Garrard KP, Muddiman DC. The development and application of matrix assisted laser desorption electrospray ionization: The teenage years. MASS SPECTROMETRY REVIEWS 2023; 42:35-66. [PMID: 34028071 DOI: 10.1002/mas.21696] [Citation(s) in RCA: 31] [Impact Index Per Article: 31.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 04/20/2021] [Accepted: 04/21/2021] [Indexed: 05/24/2023]
Abstract
In the past 15 years, ambient ionization techniques have witnessed a significant incursion into the field of mass spectrometry imaging, demonstrating their ability to provide complementary information to matrix-assisted laser desorption ionization. Matrix-assisted laser desorption electrospray ionization is one such technique that has evolved since its first demonstrations with ultraviolet lasers coupled to Fourier transform-ion cyclotron resonance mass spectrometers to extensive use with infrared lasers coupled to orbitrap-based mass spectrometers. Concurrently, there have been transformative developments of this imaging platform due to the high level of control the principal group has retained over the laser technology, data acquisition software (RastirX), instrument communication, and image processing software (MSiReader). This review will discuss the developments of MALDESI since its first laboratory demonstration in 2005 to the most recent advances in 2021.
Collapse
Affiliation(s)
- Michael Caleb Bagley
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
| | - Kenneth P Garrard
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
- The Precision Engineering Consortium, North Carolina State University, Raleigh, North Carolina, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, North Carolina, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, North Carolina, USA
- Department of Plant and Microbial Biology, North Carolina State University, Raleigh, North Carolina, USA
| |
Collapse
|
4
|
Guimaraes GJ, Bartlett MG. The critical role of mobile phase pH in the performance of oligonucleotide ion-pair liquid chromatography-mass spectrometry methods. Future Sci OA 2021; 7:FSO753. [PMID: 34840810 PMCID: PMC8610006 DOI: 10.2144/fsoa-2021-0084] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 09/29/2021] [Indexed: 11/24/2022] Open
Affiliation(s)
- Guilherme J Guimaraes
- Department of Pharmaceutical & Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, GA, USA
| | - Michael G Bartlett
- Department of Pharmaceutical & Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, GA, USA
| |
Collapse
|
5
|
Huang G, Ding Q, Xie D, Cai Z, Zhao Z. Technical challenges in defining RNA modifications. Semin Cell Dev Biol 2021; 127:155-165. [PMID: 34838434 DOI: 10.1016/j.semcdb.2021.11.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 10/28/2021] [Accepted: 11/10/2021] [Indexed: 01/27/2023]
Abstract
It is well established that DNA base modifications play a key role in gene regulation during development and in response to environmental stress. This type of epigenetic control of development and environmental responses has been intensively studied over the past few decades. Similar to DNA, various RNA species also undergo modifications that play important roles in, for example, RNA splicing, protein translation, and the avoidance of immune surveillance by host. More than 160 different types of RNA modifications have been identified. In addition to base modifications, RNA modification also involves splicing of pre-mRNAs, leading to as many as tens of transcript isoforms from a single pre-RNA, especially in higher organisms. However, the function, prevalence and distribution of RNA modifications are poorly understood. The lack of a suitable method for the reliable identification of RNA modifications constitutes a significant challenge to studying their functions. This review focuses on the technologies that enable de novo identification of RNA base modifications and the alternatively spliced mRNA transcripts.
Collapse
Affiliation(s)
- Gefei Huang
- Department of Chemistry, Hong Kong Baptist University, Hong Kong, China; State Key Laboratory of Environmental and Biological Analysis, Hong Kong Baptist University, Hong Kong, China
| | - Qiutao Ding
- Department of Biology, Hong Kong Baptist University, Hong Kong, China
| | - Dongying Xie
- Department of Biology, Hong Kong Baptist University, Hong Kong, China
| | - Zongwei Cai
- Department of Chemistry, Hong Kong Baptist University, Hong Kong, China; State Key Laboratory of Environmental and Biological Analysis, Hong Kong Baptist University, Hong Kong, China.
| | - Zhongying Zhao
- Department of Biology, Hong Kong Baptist University, Hong Kong, China; State Key Laboratory of Environmental and Biological Analysis, Hong Kong Baptist University, Hong Kong, China.
| |
Collapse
|
6
|
Sutton JM, Kim J, El Zahar NM, Bartlett MG. BIOANALYSIS AND BIOTRANSFORMATION OF OLIGONUCLEOTIDE THERAPEUTICS BY LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY. MASS SPECTROMETRY REVIEWS 2021; 40:334-358. [PMID: 32588492 DOI: 10.1002/mas.21641] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 05/05/2020] [Accepted: 05/28/2020] [Indexed: 06/11/2023]
Abstract
Since 2016, eight new oligonucleotide therapies have been approved which has led to increased interest in oligonucleotide analysis. There is a particular need for powerful bioanalytical tools to study the metabolism and biotransformation of these molecules. This review provides the background on the biological basis of these molecules as currently used in therapies. The article also reviews the current state of analytical methodology including state of the art sample preparation techniques, liquid chromatography-mass spectrometry methods, and the current limits of detection/quantitation. Finally, the article summarizes the challenges in oligonucleotide bioanalysis and provides future perspectives for this emerging field. © 2020 John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- James Michael Sutton
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352
| | - Jaeah Kim
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352
| | - Noha M El Zahar
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Organization of African Unity Street, Cairo, 11566, Egypt
| | - Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352
| |
Collapse
|
7
|
Sutton JM, El Zahar NM, Bartlett MG. Oligonucleotide Anion Adduct Formation Using Negative Ion Electrospray Ion-Mobility Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:497-508. [PMID: 33476148 DOI: 10.1021/jasms.0c00380] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Improving the mobile phase of electrospray oligonucleotides has been a major focus in the field of oligonucleotides. These improved mobile phases should reduce the charge state envelope of oligonucleotides coupled with electrospray ionization, which is key to reducing spectral complexity and increasing sensitivity. Traditional mobile phase compositions with fluorinated alcohol and alkylamine, like hexafluoroisopropanol (HFIP) and triethylamine (TEA), have a large amount of cationic adduction and many charge states. Utilizing different fluorinated alcohol and alkylamine combinations, like nonafluoro-tert-butyl alcohol (NFTB) and octylamine (OA), can selectively reduce the charge states analyzed. Other classes of biomolecules have been analyzed with anionic salts to stabilize complexes, increase the molecular peak detection, and even provide unique structural information about these molecules; however, there have been no studies using anionic salts with oligonucleotides. Our experiments systematically study the stability and binding of ammonium anionic salt. We show that anions selectively bind low charge states of these oligonucleotides. Ion-mobility measurements are made to determine the collision cross section (CCS) of these oligonucleotides with anion adduction. We utilize both a nucleic acid exact hard sphere simulation (EHSS) calibration and a protein calibration. We are able to show that NFTB/OA is a good choice for the study of oligonucleotides with reduced charge states for the binding of anionic salts and the determination of CCS using ion mobility.
Collapse
Affiliation(s)
- J Michael Sutton
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 West Green Street, Athens, Georgia 30602-2352, United States
| | - Noha M El Zahar
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 West Green Street, Athens, Georgia 30602-2352, United States
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Ain Shams University, Organization of African Unity Street, Abassia, Cairo 11566, Egypt
- Medicinal Chemistry Department, Faculty of Pharmacy, King Salman International University, Ras-Sedr, South Sinai Governorate 46612, Egypt
| | - Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 West Green Street, Athens, Georgia 30602-2352, United States
| |
Collapse
|
8
|
Bartlett MG, Omuro S. Evaluation of alkylamines and stationary phases to improve LC-MS of oligonucleotides. Biomed Chromatogr 2020; 35:e5045. [PMID: 33283300 DOI: 10.1002/bmc.5045] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 11/02/2020] [Accepted: 12/01/2020] [Indexed: 12/20/2022]
Abstract
This study evaluated four bridged-ethylene hybrid (BEH) columns containing C18 (130 Å), peptide C18 (300 Å), phenyl, or a mixed-mode charged surface hybrid (CSH C18 ) using a wide range of antisense oligonucleotide therapeutics. The BEH C18 , peptide, and phenyl columns were all capable of providing significant retention of oligonucleotide samples across multiple ion-pairing systems using alkylamines and 1,1,1,3,3,3,-hexafluoroisopropanol (HFIP). The retention of the oligonucleotides varied depending on the choice of alkylamine, with the order of retention being dimethylcyclohexylamine > diisopropylethylamine > triethylamine. The selectivity of these columns for several closely eluting impurities was similar. Although overall the C18 , peptide, and phenyl columns were all found to be capable of analyzing oligonucleotide therapeutics, the phenyl column was found to be the most retentive and the C18 column provided the best peak shape. The CSH C18 column was found to be degraded by the alkylamine-HFIP mobile phase despite the mobile phase being within the pH stability range of the column.
Collapse
Affiliation(s)
- Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, Georgia, USA
| | - Shogo Omuro
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, Georgia, USA
| |
Collapse
|
9
|
Strzelecka D, Smietanski M, Sikorski PJ, Warminski M, Kowalska J, Jemielity J. Phosphodiester modifications in mRNA poly(A) tail prevent deadenylation without compromising protein expression. RNA (NEW YORK, N.Y.) 2020; 26:1815-1837. [PMID: 32820035 PMCID: PMC7668260 DOI: 10.1261/rna.077099.120] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Accepted: 08/13/2020] [Indexed: 06/07/2023]
Abstract
Chemical modifications enable preparation of mRNAs with augmented stability and translational activity. In this study, we explored how chemical modifications of 5',3'-phosphodiester bonds in the mRNA body and poly(A) tail influence the biological properties of eukaryotic mRNA. To obtain modified and unmodified in vitro transcribed mRNAs, we used ATP and ATP analogs modified at the α-phosphate (containing either O-to-S or O-to-BH3 substitutions) and three different RNA polymerases-SP6, T7, and poly(A) polymerase. To verify the efficiency of incorporation of ATP analogs in the presence of ATP, we developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantitative assessment of modification frequency based on exhaustive degradation of the transcripts to 5'-mononucleotides. The method also estimated the average poly(A) tail lengths, thereby providing a versatile tool for establishing a structure-biological property relationship for mRNA. We found that mRNAs containing phosphorothioate groups within the poly(A) tail were substantially less susceptible to degradation by 3'-deadenylase than unmodified mRNA and were efficiently expressed in cultured cells, which makes them useful research tools and potential candidates for future development of mRNA-based therapeutics.
Collapse
Affiliation(s)
- Dominika Strzelecka
- Division of Biophysics, Institute of Experimental Physics, Faculty of Physics, University of Warsaw, 02-093 Warsaw, Poland
| | | | - Pawel J Sikorski
- Centre of New Technologies, University of Warsaw, 02-097 Warsaw, Poland
| | - Marcin Warminski
- Division of Biophysics, Institute of Experimental Physics, Faculty of Physics, University of Warsaw, 02-093 Warsaw, Poland
| | - Joanna Kowalska
- Division of Biophysics, Institute of Experimental Physics, Faculty of Physics, University of Warsaw, 02-093 Warsaw, Poland
| | - Jacek Jemielity
- Centre of New Technologies, University of Warsaw, 02-097 Warsaw, Poland
| |
Collapse
|
10
|
Chao HC, Shih M, McLuckey SA. Generation of Multiply Charged Protein Anions from Multiply Charged Protein Cations via Gas-Phase Ion/Ion Reactions. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:1509-1517. [PMID: 32421340 PMCID: PMC7332380 DOI: 10.1021/jasms.0c00062] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
We report a novel charge inversion ion/ion reaction that converts multiply charged protein cations to multiply charged protein anions via a single ion/ion collision using highly charged anions derived from nanoelectrospray ionization (nESI) of hyaluronic acids (HAs). This type of charge inversion reaction is demonstrated with cations derived from cytochrome c, apo-myoglobin, and carbonic anhydrase (CA) cations. For example, the reaction has been demonstrated to convert the [CA+22H]22+ carbonic anhydrase cation to a distribution of anions as high in absolute charge as [CA-19H]19-. Ion/ion reactions involving multiply charged ions of opposite polarity have previously been observed to result predominantly in the attachment of the reactant ions. All mechanisms for ion/ion charge inversion involving low energy ions proceed via the formation of a long-lived complex. Factors that underlie the charge inversion of protein cations to high anionic charge states in reaction with HA anions are hypothesized to include: (i) the relatively high charge densities of the HA anions that facilitate the extraction of multiple protons from the protein leading to multiply charged protein anions, (ii) the relatively high sum of absolute charges of the reactants that leads to high initial energies in the ion/ion complex, and (iii) the relatively high charge of the ion/ion complex following the multiple proton transfers that tends to destabilize the complex.
Collapse
Affiliation(s)
| | | | - Scott A. McLuckey
- Address correspondence to: Dr. Scott A. McLuckey, 560 Oval Drive, Department of Chemistry, Purdue University, West Lafayette, IN 47907-2084, USA, Phone: (765) 494-5270, Fax: (765) 494-0239,
| |
Collapse
|
11
|
Sutton JM, Bartlett MG. Modeling cationic adduction of oligonucleotides using electrospray desorption ionization. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34:e8696. [PMID: 31834644 DOI: 10.1002/rcm.8696] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 12/06/2019] [Accepted: 12/07/2019] [Indexed: 06/10/2023]
Abstract
RATIONALE Cationic adduction causes poor sensitivity and increases spectral complexity during mass spectral analysis of oligonucleotides and alkylamines are used to reduce this adduction. It is unclear the effect of the physiochemical properties of the alkylamines on the reduction of the cationic adduction. METHODS All samples were directly infused into a Synapt G2 HDMS quadrupole time-of-flight (TOF) hybrid mass spectrometer in negative ion electrospray ionization mode through the native built-in fluidics system. The infusion flow rate was set to 50 μL/min. The TOFMS tuning parameters were as follows: capillary voltage -2.0 kV, cone voltage 25 V, extraction cone voltage 2 V, source temperature 125°C, desolvation temperature 450°C, cone gas flow rate 0 L/h, and desolvation gas (nitrogen) flow rate 1000 L/h. RESULTS A quantitative model was created to predict the optimized alkylamine for MS analysis, while a qualitative model was generated to explain the most important physiochemical properties: proton affinity (13.83%), gas-phase basicity (11.79%), pKa (11.47%), boiling point (10.73%), MW (10.3%), Henry's Law Constant (9.56%), and partition coefficient (logP) (9.44%). The quantitative model was applied to RNA (microRNA) and a phosphorothioate and predicts the trend of cationic adduction. CONCLUSIONS Two models are described to understand the physiochemical properties that contribute to the adduction and to provide users a quick mathematical tool to predict the best choice of alkylamine to lower cationic adduction and decrease spectral complexity while enhancing sensitivity.
Collapse
Affiliation(s)
- J Michael Sutton
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352, USA
| | - Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352, USA
| |
Collapse
|
12
|
VanAernum ZL, Busch F, Jones BJ, Jia M, Chen Z, Boyken SE, Sahasrabuddhe A, Baker D, Wysocki VH. Rapid online buffer exchange for screening of proteins, protein complexes and cell lysates by native mass spectrometry. Nat Protoc 2020; 15:1132-1157. [PMID: 32005983 PMCID: PMC7203678 DOI: 10.1038/s41596-019-0281-0] [Citation(s) in RCA: 87] [Impact Index Per Article: 21.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Accepted: 12/06/2019] [Indexed: 01/28/2023]
Abstract
It is important to assess the identity and purity of proteins and protein complexes during and after protein purification to ensure that samples are of sufficient quality for further biochemical and structural characterization, as well as for use in consumer products, chemical processes and therapeutics. Native mass spectrometry (nMS) has become an important tool in protein analysis due to its ability to retain non-covalent interactions during measurements, making it possible to obtain protein structural information with high sensitivity and at high speed. Interferences from the presence of non-volatiles are typically alleviated by offline buffer exchange, which is time-consuming and difficult to automate. We provide a protocol for rapid online buffer exchange (OBE) nMS to directly screen structural features of pre-purified proteins, protein complexes or clarified cell lysates. In the liquid chromatography coupled to mass spectrometry (LC-MS) approach described in this protocol, samples in MS-incompatible conditions are injected onto a short size-exclusion chromatography column. Proteins and protein complexes are separated from small molecule non-volatile buffer components using an aqueous, non-denaturing mobile phase. Eluted proteins and protein complexes are detected by the mass spectrometer after electrospray ionization. Mass spectra can inform regarding protein sample purity and oligomerization, and additional tandem mass spectra can help to further obtain information on protein complex subunits. Information obtained by OBE nMS can be used for fast (<5 min) quality control and can further guide protein expression and purification optimization.
Collapse
Affiliation(s)
- Zachary L VanAernum
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, OH, USA
- Resource for Native Mass Spectrometry Guided Structural Biology, The Ohio State University, Columbus, OH, USA
| | - Florian Busch
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, OH, USA
- Resource for Native Mass Spectrometry Guided Structural Biology, The Ohio State University, Columbus, OH, USA
| | - Benjamin J Jones
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, OH, USA
- Resource for Native Mass Spectrometry Guided Structural Biology, The Ohio State University, Columbus, OH, USA
| | - Mengxuan Jia
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, OH, USA
- Resource for Native Mass Spectrometry Guided Structural Biology, The Ohio State University, Columbus, OH, USA
| | - Zibo Chen
- Department of Biochemistry, University of Washington, Seattle, WA, USA
- Institute for Protein Design, University of Washington, Seattle, WA, USA
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Scott E Boyken
- Department of Biochemistry, University of Washington, Seattle, WA, USA
- Institute for Protein Design, University of Washington, Seattle, WA, USA
- Lyell Immunopharma, Inc., Seattle, WA, USA
| | - Aniruddha Sahasrabuddhe
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, OH, USA
- Amgen Inc., Thousand Oaks, CA, USA
| | - David Baker
- Department of Biochemistry, University of Washington, Seattle, WA, USA
- Institute for Protein Design, University of Washington, Seattle, WA, USA
- Howard Hughes Medical Institute, University of Washington, Seattle, WA, USA
| | - Vicki H Wysocki
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, OH, USA.
- Resource for Native Mass Spectrometry Guided Structural Biology, The Ohio State University, Columbus, OH, USA.
| |
Collapse
|
13
|
Caleb Bagley M, Ekelöf M, Muddiman DC. Determination of Optimal Electrospray Parameters for Lipidomics in Infrared-Matrix-Assisted Laser Desorption Electrospray Ionization Mass Spectrometry Imaging. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:319-325. [PMID: 32031399 PMCID: PMC10861021 DOI: 10.1021/jasms.9b00063] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Infrared matrix-assisted laser desorption ionization (IR-MALDESI) is an ambient mass spectrometry imaging (MSI) technique that relies on electrospray ionization (ESI) for ion generation of desorbed neutrals. Although many mechanisms in IR-MALDESI have been studied in depth, there has not yet been a comprehensive study of how the ESI parameters change the profiles of tissue specific lipids. Acetonitrile (ACN)/water and methanol (MeOH)/water solvent systems and compositions were varied across a series of applied ESI voltages during IR-MALDESI analysis of rat liver tissue. Gradients of 12 min were run from 5 to 95% organic solvent in both positive and negative polarities across 11 voltages between 2.25 and 4.5 kV. These experiments informed longer gradients (25-30 min) across shorter solvent gradient ranges with fewer voltages. Optimal ESI parameters for lipidomics were determined by the number and abundance of detected lipids and the relative proportion of background ions. In positive polarity, the best solvent composition was 60-75% ACN/40-25% H2O with 0.2% formic acid at 3.2 kV applied voltage. The best parameters for negative polarity analysis are 45-55% ACN/55-45% H2O with 1 mM of acetic acid for voltages between 2.25 and 3.2 kV. Using these defined parameters, IR-MALDESI positive polarity lipidomics studies can increase lipid abundances 3-fold, with 15% greater coverage, while an abundance increase of 1.5-fold and 10% more coverage can be achieved relative to commonly used parameters in negative polarity.
Collapse
Affiliation(s)
- M. Caleb Bagley
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
| | - Måns Ekelöf
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC 27695
| |
Collapse
|
14
|
Kaczmarkiewicz A, Nuckowski Ł, Studzińska S. Analysis of the first and second generation of antisense oligonucleotides in serum samples with the use of ultra high performance liquid chromatography coupled with tandem mass spectrometry. Talanta 2019; 196:54-63. [DOI: 10.1016/j.talanta.2018.12.023] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Revised: 12/05/2018] [Accepted: 12/10/2018] [Indexed: 12/22/2022]
|
15
|
Liu R, Ruan Y, Liu Z, Gong L. The role of fluoroalcohols as counter anions for ion-pairing reversed-phase liquid chromatography/high-resolution electrospray ionization mass spectrometry analysis of oligonucleotides. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2019; 33:697-709. [PMID: 30668892 DOI: 10.1002/rcm.8386] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Revised: 01/11/2019] [Accepted: 01/11/2019] [Indexed: 06/09/2023]
Abstract
RATIONALE Hexafluoroisopropanol (HFIP) has been widely used as a counter anion in the mobile phase for ion-pairing reversed-phase liquid chromatography/mass spectrometry (IP-RP-LC/MS) analysis of oligonucleotides. However, researchers are still searching for improvements to counter anions for LC/MS analysis of oligonucleotides. This study aimed to find alternatives to HFIP for analyzing oligonucleotides. METHODS The study was performed using an Agilent 1290 ultra-high-performance liquid chromatography (UHPLC) system coupled to an Agilent 6540 mass spectrometer by using an oligonucleotide BEH C18 column (100 × 2.1 mm, 1.7 μm). Buffer systems containing ion-pairing reagents (triethylamine, tripropylamine, hexylamine, dimethylbutylamine, diisopropylethylamine, N,N-dimethylcyclohexylamine, and octylamine) and fluoroalcohols (HFIP and hexafluoro-2-methyl-2-propanol (HFTP)) were compared chromatographically and mass spectrometrically. RESULTS Results showed that HFTP has better desalting ability than HFIP, but both HFIP and HFTP have comparable effects on the separation of oligonucleotides sized from 10mer to 40mer for most of ion-pairing reagents, with the exception of triethylamine and N,N-dimethylcyclohexylamine, where HFIP performed better than HFTP. CONCLUSIONS The choice of fluoroalcohols in IP-RP-LC/MS analysis of oligonucleotides depends on the type of ion-pairing reagents used in the mobile phase. As a guideline, we would recommend to use either HA-HFIP or HA-HFTP for small oligonucleotides, but TPA-HFTP for large oligonucleotides for IP-RP-LC/MS analysis of synthetic oligonucleotides.
Collapse
Affiliation(s)
- Rong Liu
- Joint Laboratory for Translational Cancer Research of Chinese Medicine of the Ministry of Education of the People's Republic of China, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
- International Institute for Translational Chinese Medicine, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
| | - Yanjiao Ruan
- Joint Laboratory for Translational Cancer Research of Chinese Medicine of the Ministry of Education of the People's Republic of China, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
- International Institute for Translational Chinese Medicine, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
| | - Zhongqiu Liu
- Joint Laboratory for Translational Cancer Research of Chinese Medicine of the Ministry of Education of the People's Republic of China, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
- International Institute for Translational Chinese Medicine, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
| | - Lingzhi Gong
- Joint Laboratory for Translational Cancer Research of Chinese Medicine of the Ministry of Education of the People's Republic of China, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
- International Institute for Translational Chinese Medicine, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
| |
Collapse
|
16
|
Oligonucleotide analysis by hydrophilic interaction liquid chromatography-mass spectrometry in the absence of ion-pair reagents. J Chromatogr A 2019; 1595:39-48. [PMID: 30772056 DOI: 10.1016/j.chroma.2019.02.016] [Citation(s) in RCA: 56] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Revised: 02/02/2019] [Accepted: 02/06/2019] [Indexed: 01/09/2023]
Abstract
Improving our understanding of nucleic acids, both in biological and synthetic applications, remains a bustling area of research for both academic and industrial laboratories. As nucleic acids research evolves, so must the analytical techniques used to characterize nucleic acids. One powerful analytical technique has been coupled liquid chromatography - tandem mass spectrometry (LC-MS/MS). To date, the most successful chromatographic mode has been ion-pairing reversed-phase liquid chromatography. Hydrophilic interaction liquid chromatography (HILIC), in the absence of ion-pair reagents, has been investigated here as an alternative chromatographic approach to the analysis of oligonucleotides. By combining a mobile phase system using commonly employed in liquid chromatography-mass spectrometry (LC-MS) - i.e., water, acetonitrile, and ammonium acetate - and a new, commercially available diol-based HILIC column, high chromatographic and mass spectrometric performance for a wide range of oligonucleotides is demonstrated. Particular applications of HILIC-MS for the analysis of deoxynucleic acid (DNA) oligomers, modified and unmodified oligoribonucleotides, and phosphorothioate DNA oligonucleotides are presented. Based on the LC-MS performance, this HILIC-based approach provides an attractive, sensitive and robust alternative to prior ion-pairing dependent methods with potential utility for both qualitative and quantitative analyses of oligonucleotides without compromising chromatographic or mass spectrometric performance.
Collapse
|
17
|
Gong L. Analysis of oligonucleotides by ion-pairing hydrophilic interaction liquid chromatography/electrospray ionization mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2017; 31:2125-2134. [PMID: 28972295 DOI: 10.1002/rcm.8004] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2017] [Revised: 09/18/2017] [Accepted: 09/25/2017] [Indexed: 06/07/2023]
Abstract
RATIONALE Hydrophilic interaction liquid chromatography/electrospray ionization mass spectrometry (HILIC-LC/ESI-MS) has been proved to be useful for the quality control of oligonucleotides. However, the lack of separation for some oligonucleotides using HILIC-LC/MS has proved problematic. This study aimed to improve the resolving ability of HILIC-LC/MS. METHODS The study was performed on a Waters UPLC® system coupled to a Waters LCT premier XE ESI-TOF mass spectrometer using a Zorbax® RRHD HILIC column (2.1 mm × 100 mm, 1.8 μm). Buffer systems contained triethylammonium acetate (TEAA) and acetonitrile. The effects of the concentration of TEAA and the type of organic modifiers on the separation of oligonucleotides were investigated. RESULTS The results showed that the optimum concentration of TEAA is 10 mM and acetonitrile is a better organic solvent than methanol. The addition of TEAA in the HILIC mobile phase improved the separation of N from N + A significantly compared to the HILIC method buffered with ammonium acetate. The IP-HILIC chromatography has demonstrated that the separation of oligonucleotides is sequence dependent. In addition, the IP-HILIC method produces a much simpler mass spectrum of an oligonucleotide with very efficient desalting. CONCLUSIONS The HILIC-LC/MS method with the addition of TEAA at a MS-compatible concentration has improved the separation of oligonucleotides. The IP-HILIC-LC/MS method also produces very simple mass spectra with high desalting efficiency.
Collapse
Affiliation(s)
- Lingzhi Gong
- Chemistry Research Laboratory, University of Oxford, 12 Mansfield Road, Oxford, OX1 3TA, UK
| |
Collapse
|
18
|
Studzińska S. Review on investigations of antisense oligonucleotides with the use of mass spectrometry. Talanta 2017; 176:329-343. [PMID: 28917758 DOI: 10.1016/j.talanta.2017.08.025] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Revised: 08/03/2017] [Accepted: 08/07/2017] [Indexed: 11/17/2022]
Abstract
Antisense oligonucleotides have been investigated as potential drugs for years. They inhibit target gene or protein expression. The present review summarizes their modifications, modes of action, and applications of liquid chromatography coupled with mass spectrometry for qualitative and quantitative analysis of these compounds. The most recent reports on a given topic were given prominence, while some early studies were reviewed in order to provide a theoretical background. The present review covers the issues of using ion-exchange chromatography, ion-pair reversed-phase high performance liquid chromatography and hydrophilic interaction chromatography for the separation of antisense oligonucleotides. The application of mass spectrometry was described with regard to the ionization type used for the determination of these potential therapeutics. Moreover, the current approaches and applications of mass spectrometry for quantitative analysis of antisense oligonucleotides and their metabolites as well as their impurities during in vitro and in vivo studies were discussed. Finally, certain conclusions and perspectives on the determination of therapeutic oligonucleotides in various samples were briefly described.
Collapse
Affiliation(s)
- Sylwia Studzińska
- Chair of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University, 7 Gagarin Str., PL-87-100 Toruń, Poland.
| |
Collapse
|
19
|
Basiri B, Murph MM, Bartlett MG. Assessing the Interplay between the Physicochemical Parameters of Ion-Pairing Reagents and the Analyte Sequence on the Electrospray Desorption Process for Oligonucleotides. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:1647-1656. [PMID: 28405940 PMCID: PMC5569388 DOI: 10.1007/s13361-017-1671-6] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2017] [Revised: 03/10/2017] [Accepted: 03/20/2017] [Indexed: 05/25/2023]
Abstract
Alkylamines are widely used as ion-pairing agents during LC-MS of oligonucleotides. In addition to a better chromatographic separation, they also assist with the desorption of oligonucleotide ions into the gas phase, cause charge state reduction, and decrease cation adduction. However, the choice of such ion-pairing agents has considerable influence on the MS signal intensity of oligonucleotides as they can also cause significant ion suppression. Interestingly, optimal ion-pairing agents should be selected on a case by case basis as their choice is strongly influenced by the sequence of the oligonucleotide under investigation. Despite imposing major practical difficulties to analytical method development, such a highly variable system that responds very strongly to the nuances of the electrospray composition provides an excellent opportunity for a fundamental study of the electrospray ionization process. Our investigations using this system quantitatively revealed the major factors that influenced the ESI ionization efficiency of oligonucleotides. Parameters such as boiling point, proton affinity, partition coefficient, water solubility, and Henry's law constants for the ion-pairing reagents and the hydrophobic thymine content of the oligonucleotides were found to be the most significant contributors. Identification of these parameters also allowed for the development of a statistical predictive algorithm that can assist with the choice of an optimum IP agent for each particular oligonucleotide sequence. We believe that research in the field of oligonucleotide bioanalysis will significantly benefit from this algorithm (included in Supplementary Material) as it advocates for the use of lesser-known but more suitable ion-pair alternatives to TEA for many oligonucleotide sequences. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Babak Basiri
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA
| | - Mandi M Murph
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA
| | - Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA.
| |
Collapse
|
20
|
A Comprehensive Guide for Performing Sample Preparation and Top-Down Protein Analysis. Proteomes 2017; 5:proteomes5020011. [PMID: 28387712 PMCID: PMC5489772 DOI: 10.3390/proteomes5020011] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2016] [Revised: 04/04/2017] [Accepted: 04/04/2017] [Indexed: 12/21/2022] Open
Abstract
Methodologies for the global analysis of proteins in a sample, or proteome analysis, have been available since 1975 when Patrick O′Farrell published the first paper describing two-dimensional gel electrophoresis (2D-PAGE). This technique allowed the resolution of single protein isoforms, or proteoforms, into single ‘spots’ in a polyacrylamide gel, allowing the quantitation of changes in a proteoform′s abundance to ascertain changes in an organism′s phenotype when conditions change. In pursuit of the comprehensive profiling of the proteome, significant advances in technology have made the identification and quantitation of intact proteoforms from complex mixtures of proteins more routine, allowing analysis of the proteome from the ‘Top-Down’. However, the number of proteoforms detected by Top-Down methodologies such as 2D-PAGE or mass spectrometry has not significantly increased since O’Farrell’s paper when compared to Bottom-Up, peptide-centric techniques. This article explores and explains the numerous methodologies and technologies available to analyse the proteome from the Top-Down with a strong emphasis on the necessity to analyse intact proteoforms as a better indicator of changes in biology and phenotype. We arrive at the conclusion that the complete and comprehensive profiling of an organism′s proteome is still, at present, beyond our reach but the continuing evolution of protein fractionation techniques and mass spectrometry brings comprehensive Top-Down proteome profiling closer.
Collapse
|
21
|
Basiri B, van Hattum H, van Dongen WD, Murph MM, Bartlett MG. The Role of Fluorinated Alcohols as Mobile Phase Modifiers for LC-MS Analysis of Oligonucleotides. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:190-199. [PMID: 27644940 PMCID: PMC5500909 DOI: 10.1007/s13361-016-1500-3] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Revised: 08/30/2016] [Accepted: 08/31/2016] [Indexed: 06/06/2023]
Abstract
Hexafluoroisopropanol (HFIP) has been widely used as an acidic modifier for mobile phases for liquid chromatography-mass spectrometry (LC-MS) analysis of oligonucleotides ever since the first report of its use for this purpose. This is not surprising, considering the exceptional performance of HFIP compared with carboxylic acids, which cause significant MS signal suppression in electrospray ionization. However, we have found that other fluorinated alcohols can also be utilized for mobile phase preparation and the choice of optimal fluorinated alcohol is determined by the ion-pairing (IP) agent. Although HFIP is a very good choice to be used alongside less hydrophobic IP agents, other fluorinated alcohols such as 1,1,1,3,3,3-hexafluoro-2-methyl-2-propanol (HFMIP) can significantly outperform HFIP when used with more hydrophobic IP agents. We also found that more acidic fluorinated alcohols assist with the transfer of oligonucleotides with secondary structure (e.g., folded strands and hairpins) into the gas phase. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Babak Basiri
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA
| | - Hilde van Hattum
- ProQR Therapeutics NV, Zernikedreef 9, 2333 CK, Leiden, The Netherlands
| | | | - Mandi M Murph
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA
| | - Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, The University of Georgia College of Pharmacy, 250 W. Green Street, Athens, GA, 30602-2352, USA.
| |
Collapse
|
22
|
Reversed-phase separation methods for glycan analysis. Anal Bioanal Chem 2016; 409:359-378. [PMID: 27888305 PMCID: PMC5203856 DOI: 10.1007/s00216-016-0073-0] [Citation(s) in RCA: 69] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 10/26/2016] [Accepted: 10/31/2016] [Indexed: 12/21/2022]
Abstract
Reversed-phase chromatography is a method that is often used for glycan separation. For this, glycans are often derivatized with a hydrophobic tag to achieve retention on hydrophobic stationary phases. The separation and elution order of glycans in reversed-phase chromatography is highly dependent on the hydrophobicity of the tag and the contribution of the glycan itself to the retention. The contribution of the different monosaccharides to the retention strongly depends on the position and linkage, and isomer separation may be achieved. The influence of sialic acids and fucoses on the retention of glycans is still incompletely understood and deserves further study. Analysis of complex samples may come with incomplete separation of glycan species, thereby complicating reversed-phase chromatography with fluorescence or UV detection, whereas coupling with mass spectrometry detection allows the resolution of complex mixtures. Depending on the column properties, eluents, and run time, separation of isomeric and isobaric structures can be accomplished with reversed-phase chromatography. Alternatively, porous graphitized carbon chromatography and hydrophilic interaction liquid chromatography are also able to separate isomeric and isobaric structures, generally without the necessity of glycan labeling. Hydrophilic interaction liquid chromatography, porous graphitized carbon chromatography, and reversed-phase chromatography all serve different research purposes and thus can be used for different research questions. A great advantage of reversed-phase chromatography is its broad distribution as it is used in virtually every bioanalytical research laboratory, making it an attracting platform for glycan analysis. Glycan isomer separation by reversed phase liquid chromatography ![]()
Collapse
|
23
|
Birdsall RE, Gilar M, Shion H, Yu YQ, Chen W. Reduction of metal adducts in oligonucleotide mass spectra in ion-pair reversed-phase chromatography/mass spectrometry analysis. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2016; 30:1667-1679. [PMID: 28328039 PMCID: PMC5094505 DOI: 10.1002/rcm.7596] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2016] [Revised: 04/28/2016] [Accepted: 05/01/2016] [Indexed: 05/09/2023]
Abstract
RATIONALE Electrospray ionization mass spectrometry (ESI-MS)-based techniques commonly used in oligonucleotide analyses are known to be sensitive to alkali metal adduct formation. Adducts directly impact the sensitivity of MS-based analyses as the available charge is distributed across the parent peak and adduct(s). The current study systematically evaluated common liquid chromatography (LC) components in LC/ESI-MS configurations used in oligonucleotide analysis to identify metal adduct contributions from LC instrumentation. METHODS A UPLC liquid chromatography system was configured with a single quadrupole MS detector (ACQUITY QDa, Waters Corp.) to monitor adduct formation in oligonucleotide separations. An ion-pairing mobile phase comprised of 15 mM triethylamine and 400 mM hexafluoro-2-propanol was used in conjunction with an oligonucleotide separation column (Waters OST BEH C18, 2.1 mm × 50 mm) for all separations. A 10-min method was used to provide statistical figures of merit and evaluate adduct formation over time. RESULTS Trace alkali metal salts in the mobile phase and reagents were determined to be the main source of metal salt adducts in LC/ESI-MS-based configurations. Non-specific adsorption sites located throughout the fluidic path contribute to adduct formation in oligonucleotide analyses. Ion-pairing mobile phases prepared at neutral or slightly basic pH result in up to a 57% loss of spectral abundance to adduct formation in the current study. CONCLUSIONS Implementation of a short low pH reconditioning step was observed to effectively displace trace metal salts non-specifically adsorbed to surfaces in the fluidic path and was able to maintain an average MS spectral abundance ≥94% with a high degree of repeatability (relative standard deviation (R.S.D.) 0.8%) over an extended time study. The proposed method offers the ability to rapidly regenerate adsorption sites with minimal impact on productivity while retaining assay sensitivity afforded by MS detection with reduced adduct formation. © 2016 The Authors. Rapid Communications in Mass Spectrometry Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
| | - Martin Gilar
- Waters Corp., 34 Maple St, Milford, MA, 01757-3604, USA
| | - Henry Shion
- Waters Corp., 34 Maple St, Milford, MA, 01757-3604, USA
| | - Ying Qing Yu
- Waters Corp., 34 Maple St, Milford, MA, 01757-3604, USA
| | - Weibin Chen
- Waters Corp., 34 Maple St, Milford, MA, 01757-3604, USA
| |
Collapse
|
24
|
Stutzman JR, Crowe MC, Alexander JN, Bell BM, Dunkle MN. Coupling Charge Reduction Mass Spectrometry to Liquid Chromatography for Complex Mixture Analysis. Anal Chem 2016; 88:4130-9. [DOI: 10.1021/acs.analchem.6b00485] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- John R. Stutzman
- Analytical
Sciences, The Dow Chemical Company, 1897 Building, Midland, Michigan 48667, United States
| | - Matthew C. Crowe
- Analytical
Sciences, The Dow Chemical Company, Collegeville, Pennsylvania 19426, United States
| | - James N. Alexander
- Analytical
Sciences, The Dow Chemical Company, Collegeville, Pennsylvania 19426, United States
| | - Bruce M. Bell
- Analytical
Sciences, The Dow Chemical Company, 1897 Building, Midland, Michigan 48667, United States
| | - Melissa N. Dunkle
- Analytical
Sciences, The Dow Chemical Company, Herbert H. Dowweg 5, ADD2/8, 4542 NM Hoek, Netherlands
| |
Collapse
|
25
|
McGinnis AC, Grubb EC, Bartlett MG. Systematic optimization of ion-pairing agents and hexafluoroisopropanol for enhanced electrospray ionization mass spectrometry of oligonucleotides. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2013; 27:2655-2664. [PMID: 24591027 DOI: 10.1002/rcm.6733] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2013] [Revised: 09/03/2013] [Accepted: 09/04/2013] [Indexed: 06/03/2023]
Abstract
RATIONALE New methods to enhance the electrospray ionization (ESI) signals are essential for low-level analysis of oligonucleotides. We report a systematic evaluation comparing 13 ion-pairing agents with and without hexafluoroisopropanol to understand their effect on the ion abundance of hetero-oligonucleotides. METHODS A Waters Synapt G2 HDMS quadrupole time-of-flight instrument was used to compare oligonucleotide signal intensity with 13 alkylamine ion-pairing agents at varying concentrations. The alkylamines that yielded the highest signal intensity were further evaluated with hexafluoroisopropanol at concentrations between 5 and 100 mM. The chemical properties of the solution components and analytes were evaluated to identify key factors in predicting optimal mobile phase conditions for different classes of oligonucleotides. RESULTS We identified a series of optimized mobile phase systems using diisopropylamine, tripropylamine, dimethylbutylamine, methyldibutylamine, and dimethylhexylamine along with 25 to 50 mM hexafluoroisopropanol that yielded significantly higher MS signal intensity for both siRNA and DNA compared with the traditionally used triethlyamine/hexafluoroisopropanol system. We explored charge state reduction, adduct formation and ESI mechanisms and identify the Henry's Law constant k aq/g as a key chemical property in predicting alkylamines that will increase oligonucleotide ion intensity. We also find that the hydrophobicity of the oligonucleotide plays a major role in choosing ion-pairing agents that will increase ion abundance. CONCLUSIONS This comprehensive and systematic optimization finds that the hydrophobicity of the oligonucleotide was a key factor in choosing alkylamine ion-pairing agents to increase ESI abundance. We identified that diisopropylamine and tripropylamine combined with lower concentrations of hexafluoroisopropanol yielded the highest signal intensity for these oligonucleotides.
Collapse
Affiliation(s)
- A Cary McGinnis
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, The University of Georgia, Athens, GA, 30602-2352, USA
| | | | | |
Collapse
|
26
|
Erb R, Oberacher H. Comparison of mobile-phase systems commonly applied in liquid chromatography-mass spectrometry of nucleic acids. Electrophoresis 2013; 35:1226-35. [PMID: 24123202 DOI: 10.1002/elps.201300269] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2013] [Revised: 07/25/2013] [Accepted: 08/12/2013] [Indexed: 11/08/2022]
Abstract
LC-MS represents an important technology for the qualitative and quantitative analysis of nucleic acids. For MS, ESI in negative ion mode is used. The chromatographic method of choice is ion-pair (IP) RP chromatography. Chromatographic separations are usually accomplished by gradients of an organic modifier in aqueous solutions of IP reagents. Commonly applied IP reagents are 2.3 mM triethylamine/400 mM 1,1,1,3,3,3-hexafluoro-2-propanol (TEA/HFIP, pH 7.0) and 10-25 mM cyclohexyldimethylammonium acetate (CycHDMAA, pH 8.4). Direct comparison of mass spectrometric performance of the two solvent systems revealed that the TEA/HFIP system offers better detection sensitivity than the CycHDMAA system. This is mainly attributable to the depletion of HFIP during droplet formation and solvent evaporation. Removal of the anionic counterion facilitates oligonucleotide ionization, and the oligonucleotides are desorbed as highly charged ions into the gas phase. TEA/HFIP-based mobile phases are recommended for developing quantitative assays targeting defined oligonucleotides. The CycHDMAA system allows the formation of cyclohexyldimethylammonium adducts. These adducts are cleaved in the gas phase, and this decomposition gives rise to charge state reduction. Ammonium adduct formation is of particular importance in preventing adducting with metal ions. Thus, adducts with metal ions are efficiently suppressed with CycHDMAA. For the TEA/HFIP system, however, such adducting represents a severe problem particularly if large oligonucleotides are analyzed. Thus, CycHDMAA-based mobile phases are recommended for qualitative assays such as LC-MS-based genotyping.
Collapse
Affiliation(s)
- Robert Erb
- Institute of Legal Medicine and Core Facility Metabolomics, Innsbruck Medical University, Innsbruck, Austria
| | | |
Collapse
|
27
|
Silvestri C, Brodbelt JS. Tandem mass spectrometry for characterization of covalent adducts of DNA with anticancer therapeutics. MASS SPECTROMETRY REVIEWS 2013; 32:247-66. [PMID: 23150278 PMCID: PMC3578003 DOI: 10.1002/mas.21363] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2012] [Revised: 08/17/2012] [Accepted: 08/18/2012] [Indexed: 05/17/2023]
Abstract
The chemotherapeutic activities of many anticancer and antibacterial drugs arise from their interactions with nucleic acid substrates. Some of these ligands interact with DNA in a way that causes conformational changes or damage to the nucleic acid targets, ultimately altering recognition by key DNA-specific enzymes, interfering with DNA transcription or prohibiting replication, and terminating cell growth and proliferation. The design and synthesis of ligands that bind to nucleic acids remains a dynamic field in medicinal chemistry and pharmaceutical research. The quest for more selective and efficacious DNA-interactive anticancer chemotherapeutics has likewise catalyzed the need for sensitive analytical methods that can provide structural information about the nature of the resulting DNA adducts and provide insight into the mechanistic pathways of the DNA/drug interactions and the impact on the cellular processes in biological systems. This review focuses on the array of tandem mass spectrometric strategies developed and applied for characterization of covalent adducts formed between DNA and anticancer ligands.
Collapse
Affiliation(s)
- Catherine Silvestri
- Department of Chemistry and Biochemistry, University of Texas at Austin, Austin, TX 78712, USA
| | | |
Collapse
|
28
|
Prentice BM, McLuckey SA. Gas-phase ion/ion reactions of peptides and proteins: acid/base, redox, and covalent chemistries. Chem Commun (Camb) 2013; 49:947-65. [PMID: 23257901 PMCID: PMC3557538 DOI: 10.1039/c2cc36577d] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Gas-phase ion/ion reactions are emerging as useful and flexible means for the manipulation and characterization of peptide and protein biopolymers. Acid/base-like chemical reactions (i.e., proton transfer reactions) and reduction/oxidation (redox) reactions (i.e., electron transfer reactions) represent relatively mature classes of gas-phase chemical reactions. Even so, especially in regards to redox chemistry, the widespread utility of these two types of chemistries is undergoing rapid growth and development. Additionally, a relatively new class of gas-phase ion/ion transformations is emerging which involves the selective formation of functional-group-specific covalent bonds. This feature details our current work and perspective on the developments and current capabilities of these three areas of ion/ion chemistry with an eye towards possible future directions of the field.
Collapse
Affiliation(s)
- Boone M. Prentice
- Purdue University – Department of Chemistry, 560 Oval Drive, West Lafayette, IN, 47907-2084, USA
| | - Scott A. McLuckey
- Purdue University – Department of Chemistry, 560 Oval Drive, West Lafayette, IN, 47907-2084, USA
| |
Collapse
|
29
|
Chen B, Mason SF, Bartlett MG. The effect of organic modifiers on electrospray ionization charge-state distribution and desorption efficiency for oligonucleotides. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2013; 24:257-264. [PMID: 23325666 DOI: 10.1007/s13361-012-0509-5] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2012] [Revised: 09/21/2012] [Accepted: 09/26/2012] [Indexed: 06/01/2023]
Abstract
The chemical composition of the solution has a critical impact on the electrospray desorption efficiency of oligonucleotides. Several physiochemical properties of various organic modifiers were investigated with respect to their role in the desorption process of oligonucleotides. The Henry's Law Constant, which reflects the volatility of alkylamines, was found to have a prominent effect on both the electrospray charge state distribution and desorption efficiency of oligonucleotides. Alkylamines with higher k(H,cc)(aq/gas) values such as hexylamine, piperidine, and imidazole reduced the charge state distribution by forming complexes with the oligonucleotide and dissociating from it in the gas phase, while alkylamines with extremely low k(H,cc)(aq/gas) values reduced the electrospray charge state distribution by facilitating ion emission at an earlier stage of the electrospray desorption process. Ion-pairing agents with moderate k(H,cc)(aq/gas) values do not alter the electrospray charge state distribution of oligonucleotides and their ability to enhance oligonucleotide ionization followed the order of decreasing k(H,cc)(aq/gas) values. The Henry's Law Constant also correlated to the impact of the acidic modifiers on oligonucleotide ionization efficiency. Ionization enhancement effects were observed with hexafluoroisopropanol, and this effect was attributed to its low k(H,cc)(aq/gas) and moderate acidity. The comprehensive effects of both alkylamine and hexafluoroisoproapnol on the electrospray ionization desorption of oligonucleotides were also evaluated, and acid-base equilibrium was found to play a critical role in determining these effects.
Collapse
Affiliation(s)
- Buyun Chen
- Department of Pharmaceutical and Biomedical Science, College of Pharmacy, The University of Georgia, Athens, GA 30602-2352, USA
| | | | | |
Collapse
|
30
|
Huber CG, Krajete A. Analysis of nucleic acids by capillary ion-pair reversed-phase HPLC coupled to negative-ion electrospray ionization mass spectrometry. Anal Chem 2012; 71:3730-9. [PMID: 21662880 DOI: 10.1021/ac990378j] [Citation(s) in RCA: 104] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Ion-pair reversed-phase high-performance liquid chromatography was successfully coupled to negative-ion electrospray ionization mass spectrometry by using 60 × 0.20 mm i.d. capillary columns packed with 2.3-μm micropellicular, octadecylated poly(styrene/divinylbenzene) particles as stationary phase and gradients of acetonitrile in 50 mM aqueous triethylammonium bicarbonate as mobile phase. Systematic variation of the eluent composition, such as concentration of ion-pair reagent, anion in the ion-pair reagent, solution pH, and acetonitrile concentration led to the conclusion that most parameters have opposite effects on chromatographic and mass spectrometric performances. The use of acetonitrile as sheath liquid enabled the rapid and highly efficient separation and detection of phosphorylated and nonphosphorylated oligonucleotides ranging in size from 8 to 40 nucleotides. High-quality full-scan mass spectra showing little cation adduction were acquired from which the molecular masses of the separated oligonucleotides were calculated with an accuracy of 0.011%. With calibration curves being linear over at least 2 orders of magnitude, the lower limits of detection for a oligodeoxythymidine 16-mer were 104 fmol with full scan and 710 amol with selected-ion-monitoring data acquisition. The potential of ion-pair reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry was demonstrated for mixed-sequence oligomers by the characterization of a reaction mixture from solid-phase synthesis of a 40-mer oligonucleotide.
Collapse
Affiliation(s)
- C G Huber
- Institute of Analytical Chemistry and Radiochemistry, Leopold-Franzens-University, Innrain 52a, A-6020 Innsbruck, Austria
| | | |
Collapse
|
31
|
Erb R, Leithner K, Bernkop-Schnürch A, Oberacher H. Phosphorothioate oligonucleotide quantification by μ-liquid chromatography-mass spectrometry. AAPS JOURNAL 2012; 14:728-37. [PMID: 22806756 DOI: 10.1208/s12248-012-9381-2] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2011] [Accepted: 06/06/2012] [Indexed: 12/23/2022]
Abstract
Phosporothioate oligonucleotides represent an important class of therapeutic oligonucleotides, in which none-bridging oxygen atoms of the phosphate groups are replaced by sulfur. These oligonucleotides are designed to treat disease by modulating gene expression of an affected individual. As the development and application of these therapeutical oligonucleotides require analytical support, the development, validation, and application of an assay for the quantitative analysis of a phosporothioate oligonucleotide in rat plasma is described. The method employs ion-pair reversed-phase chromatography on a monolithic capillary column with acetonitrile gradients in cyclohexyldimethylammonium acetate for separation and high-resolution tandem mass spectrometry for detection of nucleic acids. Chromatographic parameters (i.e. column temperature, mobile phase composition) as well as mass spectrometric parameters (i.e. spray voltage, gas flow, and capillary position, scan mode) have been optimized for sensitive oligonucleotide quantification. Furthermore, a solid-phase extraction method was developed which enabled processing of 10 μl of plasma. The five-point calibration curve showed linearity over the range of concentrations from 100 to 1,000 nM of the oligonucleotide. The limit of detection was 50 nM. The intra- and inter-day precision and accuracies were always better than 10.2 %. Using this assay, we performed a pharmacokinetic study of the phosporothioate oligonucleotide in rat treated with a single intravenous dose of 0.39 μmol/kg. The assay sensitivity was sufficient to study the early phase elimination of the oligonucleotide. Small amounts of the oligonucleotide were detectable up to 3 h after dosing.
Collapse
Affiliation(s)
- Robert Erb
- Institute of Legal Medicine, Innsbruck Medical University, Muellerstrasse 44, 6020, Innsbruck, Austria
| | | | | | | |
Collapse
|
32
|
Kharlamova A, DeMuth JC, McLuckey SA. Vapor treatment of electrospray droplets: evidence for the folding of initially denatured proteins on the sub-millisecond time-scale. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2012; 23:88-101. [PMID: 22016004 DOI: 10.1007/s13361-011-0258-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2011] [Revised: 09/16/2011] [Accepted: 09/18/2011] [Indexed: 05/31/2023]
Abstract
The exposure of electrospray droplets generated from either highly acidic or highly basic solutions to basic or acidic vapors, respectively, admitted into the counter-current drying gas, has been shown to lead to significant changes in the observed charge state distributions of proteins. In both cases, distributions of charge states changed from relatively high charge states, indicative of largely denatured proteins, to lower charge state distributions that are more consistent with native protein conformations. Ubiquitin, cytochrome c, myoglobin, and carbonic anhydrase were used as model systems. In some cases, bimodal distributions were observed that are not noted under any solution pH conditions. The extent to which changes in charge state distributions occur depends upon the initial solution pH and the pK(a) or pK(b) of the acidic or basic reagent, respectively. The evolution of charged droplets in the sampling region of the mass spectrometer inlet aperture, where the vapor exposure takes place, occurs within roughly 1 ms. The observed changes in the spectra, therefore, are a function of the magnitude of the pH change as well as the rates at which the proteins can respond to this change. The exposure of electrospray droplets in this fashion may provide means for accessing transient folding states for further characterization by mass spectrometry.
Collapse
Affiliation(s)
- Anastasia Kharlamova
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN 47907-2084, USA
| | | | | |
Collapse
|
33
|
Beverly MB. Applications of mass spectrometry to the study of siRNA. MASS SPECTROMETRY REVIEWS 2011; 30:979-998. [PMID: 20201110 DOI: 10.1002/mas.20260] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2008] [Revised: 08/13/2009] [Accepted: 08/13/2009] [Indexed: 05/28/2023]
Abstract
RNA interference (RNAi) has quickly become a well-established laboratory tool for regulating gene expression and is currently being explored for its therapeutic potential. The design and use of double-stranded RNA oligonucleotides as therapeutics to trigger the RNAi mechanism and a greater effort to understand the RNAi pathway itself is driving the development of analytical techniques that can characterize these oligonucleotides. Electrospray (ESI) and MALDI have been used routinely to analyze oligonucleotides and their ability to provide mass and sequence information has made them ideal for this application. Reviewed here is the work done to date on the use of ESI and MALDI for the study of RNAi oligonucleotides as well as the strategies and issues associated with siRNA analysis by mass spectrometry. While there is not a large body of literature on the specific application of mass spectrometry to RNAi, the work done in this area is a good demonstration of the range of experiments that can be conducted and the value that ESI and MALDI can provide to the RNAi field.
Collapse
Affiliation(s)
- Michael B Beverly
- RNA Therapeutics Department, Merck and Co., Inc., Boulder, CO 80301, USA.
| |
Collapse
|
34
|
McGinnis AC, Chen B, Bartlett MG. Chromatographic methods for the determination of therapeutic oligonucleotides. J Chromatogr B Analyt Technol Biomed Life Sci 2011; 883-884:76-94. [PMID: 21945211 DOI: 10.1016/j.jchromb.2011.09.007] [Citation(s) in RCA: 92] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2011] [Revised: 08/31/2011] [Accepted: 09/05/2011] [Indexed: 11/25/2022]
Abstract
Both DNA and RNA are being explored for their therapeutic potential against a wide range of diseases. As these new drugs emerge, new demands arise for the analysis and quantitation of these biomolecules. Pharmacokinetic and pharmacodynamic analysis requirements for drug approval place enormous challenges on the methods for analyzing these therapeutics. This review will focus on bioanalytical methods for DNA antisense and aptamers as well as small-interfering RNA (siRNA) therapeutics. Chromatography methods employing ultraviolet (UV), fluorescence and mass spectrometric (MS) detection along with matrix-assisted laser desorption/ionization (MALDI) will be covered. Sample preparation from biological matrices will be reviewed as well as metabolite analysis and identification. All of these techniques are important contributions toward oligonucleotide therapeutic development. They will also be important in microRNA (miRNA) biomarker discovery and RNomics in general, as more non-coding RNAs are inevitably discovered.
Collapse
Affiliation(s)
- A Cary McGinnis
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, GA 30602-2352, USA
| | | | | |
Collapse
|
35
|
Abstract
Therapeutic oligonucleotides (OGNTs) are important biopharmaceutical drugs for the future, due to their ability to selectively reduce or knockout the expression of target genes. For the development of OGNTs, reliable and relatively high-throughput bioanalytical methods are required to perform the quantitative bioanalysis of OGNTs and their metabolites in biological fluids (e.g., plasma, urine and tissue). Although immunoaffinity methods, especially ELISA, are currently widely applied for this purpose, the potential of LC-MS in OGNT analysis is under investigation. Owing to its inherent ability to monitor the individual target OGNTs as well as their metabolites, LC-MS is now evolving into the method-of-choice for the bioanalysis of OGNTs. In this paper, the state-of-the-art of bioanalytical LC-MS of OGNTs and their metabolites in biological fluids is critically reviewed and its advantages and limitations highlighted. Finally, the future perspective of bioanalytical LC-MS, that is, lower detection levels and potential generic LC-MS methodology, is discussed.
Collapse
|
36
|
Nasioudis A, Heeren RMA, van Doormalen I, de Wijs-Rot N, van den Brink OF. Electrospray ionization tandem mass spectrometry of ammonium cationized polyethers. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2011; 22:837-844. [PMID: 21472518 DOI: 10.1007/s13361-011-0101-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2010] [Revised: 01/22/2011] [Accepted: 02/03/2011] [Indexed: 05/30/2023]
Abstract
Quaternary ammonium salts (Quats) and amines are known to facilitate the MS analysis of high molar mass polyethers by forming low charge state adduct ions. The formation, stability, and behavior upon collision-induced dissociation (CID) of adduct ions of polyethers with a variety of Quats and amines were studied by electrospray ionization quadrupole time-of-flight, quadrupole ion trap, and linear ion trap tandem mass spectrometry (MS/MS). The linear ion trap instrument was part of an Orbitrap hybrid mass spectrometer that allowed accurate mass MS/MS measurements. The Quats and amines studied were of different degree of substitution, structure, and size. The stability of the adduct ions was related to the structure of the cation, especially the amine's degree of substitution. CID of singly/doubly charged primary and tertiary ammonium cationized polymers resulted in the neutral loss of the amine followed by fragmentation of the protonated product ions. The latter reveals information about the monomer unit, polymer sequence, and endgroup structure. In addition, the detection of product ions retaining the ammonium ion was observed. The predominant process in the CID of singly charged quaternary ammonium cationized polymers was cation detachment, whereas their doubly charged adduct ions provided the same information as the primary and tertiary ammonium cationized adduct ions. This study shows the potential of specific amines as tools for the structural elucidation of high molar mass polyethers.
Collapse
Affiliation(s)
- Andreas Nasioudis
- AkzoNobel Research, Development and Innovation, P.O. Box 10, 7400 AA, Deventer, The Netherlands
| | | | | | | | | |
Collapse
|
37
|
Ganisl B, Taucher M, Riml C, Breuker K. Charge as you like! Efficient manipulation of negative ion net charge in electrospray ionization of proteins and nucleic acids. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2011; 17:333-343. [PMID: 22006635 DOI: 10.1255/ejms.1140] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Acidic proteins and nucleic acids such as RNA are most readily ionized in electrospray ionization (ESI) operated in negative-ion mode. The multiply deprotonated protein or RNA ions can be used as precursors in top- down mass spectrometry. Because the performance of the dissociation method used critically depends on precursor ion negative net charge, it is important that the extent of charging in ESI can be manipulated efficiently. We show here that (M - nH)(n-) ion net charge of proteins and RNA can be controlled efficiently by the addition of organic bases to the electrosprayed solution. Our study also highlights the fact that ion formation in ESI in negative mode is only poorly understood.
Collapse
|
38
|
Kharlamova A, McLuckey SA. Negative electrospray droplet exposure to gaseous bases for the manipulation of protein charge state distributions. Anal Chem 2010; 83:431-7. [PMID: 21141935 DOI: 10.1021/ac1027319] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
The exposure of electrospray droplets to vapors of reagents of various base strengths affects protein negative charge state distributions independent of initial solution conditions. Volatile bases are introduced into the counter-current nitrogen drying gas of an electrospray interface to interact with charged droplets as they undergo desolvation/disintegration, shifting charge state distributions of proteins to higher, more negative, charge states. Alterations of charge state distributions can implicate protein folding/unfolding phenomena. Species bound by relatively weak interactions can be preserved, at least to some extent, allowing for the observation of high charge states of protein-ligand complexes, such as high negative charge states of holomyoglobin. The binding of carbonic anhydrase with its Zn(2+) cofactor is apparently preserved when the holo-form of the protein is exposed to basic vapors (i.e., the Zn(2+) ion remains associated with the protein), but this prevents the appearance of charge states higher than -17. Charge state distributions of proteins containing disulfide bonds shift slightly with the leak-in of basic vapors, but when these disulfide bonds are reduced with dithiothreitol in solution, charge states higher than the number of acidic sites (Asp, Glu, and C-terminus) are observed. Since there is no observed change in the distributions of buffered proteins exposed to these reagent vapors, the charge state changes are attributed largely to a pH affect. High pK(a) and highly volatile reagents have been found to be the most effective in terms of observing the maximum negative charge state of the biomolecule of interest.
Collapse
Affiliation(s)
- Anastasia Kharlamova
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907-2084, United States
| | | |
Collapse
|
39
|
Campbell JL, Le Blanc JCY. Targeted ion parking for the quantitation of biotherapeutic proteins: concepts and preliminary data. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2010; 21:2011-2022. [PMID: 20926309 DOI: 10.1016/j.jasms.2010.08.015] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2010] [Revised: 08/17/2010] [Accepted: 08/21/2010] [Indexed: 05/30/2023]
Abstract
Targeted ion parking (or TIPing) is the first quantitative application of ion/ion reactions for mass spectrometry. In TIPing, intact biotherapeutic proteins are electrosprayed as intact molecules (no digestion) and, as expected, many multiply protonated species are produced (e.g., (M + 7H)(7+), (M + 8H)(8+), etc.). Several of these multiply charged species are selectively isolated using a quadrupole mass analyzer and then contained in a linear ion trap. The protein ions are then subjected to a proton-transfer reaction with a reagent anion. The ions undergo sequential charge reduction (e.g., to (M + 6H)(6+)) during a defined reaction period. Applying a low-amplitude waveform to the trap during this reaction time stops the ion/ion reaction at a chosen (and predicted) charge state for the protein. This funnels the analyte ions into a single channel with relatively high efficiency (>50% of reactant ion signal is converted into product ion signal) that can be used for quantitation. In TIPing, the target protein's molecular weight and charge state distribution are the only prerequisite knowledge required. This information can be acquired experimentally or can be easily predicted based upon amino acid sequences. Preliminary data for a biotherapeutic protein, a domain antibody, were collected using TIPing coupled online with liquid chromatography (LC-TIPing). The LC-TIPing data demonstrate a linear response for samples from 10-1000 ng/mL extracted from a complex plasma sample, demonstrating the analytical potential for TIPing.
Collapse
|
40
|
Nasioudis A, Joyce WF, van Velde JW, Heeren RMA, van den Brink OF. Formation of low charge state ions of synthetic polymers using quaternary ammonium compounds. Anal Chem 2010; 82:5735-42. [PMID: 20521768 DOI: 10.1021/ac100769u] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Factors such as high polymer dispersity and variation in elemental composition (of copolymers) often complicate the electrospray ionization mass spectrometry (ESI-MS) analysis of synthetic polymers with high molar mass. In the experiments described in this study, quaternary ammonium compounds were observed to facilitate the production of low charge state pseudomolecular ions when added to the spray solution for ESI-MS. This approach was then used for the ESI time-of-flight mass spectrometry (TOF-MS) analysis of synthetic polymers. Hexadecyltrimethylammonium chloride permitted the successful analysis of poly(ethylene glycol) of 2-40 kDa, poly(propylene glycol) and poly(tetramethylene glycol) oligomers. Increasing the quaternary ammonium compounds' concentration results in the production of low charge state pseudomolecular ions. A comparison of structurally different quaternary ammonium compounds showed that the best performance is expected from large molecules with specific charge localization, which leaves the charge available for interactions. The applicability of the method for the MS analysis of other polymeric systems was also studied. In the case of poly(tetramethylene glycol), the method not only shifted the distributions to higher m/z values but also allowed the detection of high molecular weight material that was not observed without addition of the modifier to the spray solution.
Collapse
Affiliation(s)
- Andreas Nasioudis
- AkzoNobel Research, Development & Innovation, Deventer, The Netherlands
| | | | | | | | | |
Collapse
|
41
|
Fabris D. A role for the MS analysis of nucleic acids in the post-genomics age. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2010; 21:1-13. [PMID: 19897384 DOI: 10.1016/j.jasms.2009.09.006] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2009] [Revised: 09/04/2009] [Accepted: 09/04/2009] [Indexed: 05/28/2023]
Abstract
The advances of mass spectrometry in the analysis of nucleic acids have tracked very closely the exciting developments of instrumentation and ancillary technologies, which have taken place over the years. However, their diffusion in the broader life sciences community has been and will be linked to the ever evolving focus of biomedical research and its changing demands. Before the completion of the Human Genome Project, great emphasis was placed on sequencing technologies that could help accomplish this project of exceptional scale. After the publication of the human genome, the emphasis switched toward techniques dedicated to the exploration of sequences not coding for actual protein products, which amount to the vast majority of transcribed elements. The broad range of capabilities offered by mass spectrometry is rapidly advancing this platform to the forefront of the technologies employed for the structure-function investigation of these noncoding elements. Increasing focus on the characterization of functional assemblies and their specific interactions has prompted a re-evaluation of what has been traditionally construed as nucleic acid analysis by mass spectrometry. Inspired by the accelerating expansion of the broader field of nucleic acid research, new applications to fundamental biological studies and drug discovery will help redefine the evolving role of MS-analysis of nucleic acids in the post-genomics age.
Collapse
Affiliation(s)
- Daniele Fabris
- Department of Chemistry and Biochemistry, University of Maryland Baltimore County, Baltimore, Maryland 21228, USA.
| |
Collapse
|
42
|
Przybylski C, Gonnet F, Bonnaffé D, Hersant Y, Lortat-Jacob H, Daniel R. HABA-based ionic liquid matrices for UV-MALDI-MS analysis of heparin and heparan sulfate oligosaccharides. Glycobiology 2009; 20:224-34. [DOI: 10.1093/glycob/cwp169] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
43
|
Sioud S, Genestie B, Jahouh F, Martin P, Banoub J. Gas-phase fragmentation study of biotin reagents using electrospray ionization tandem mass spectrometry on a quadrupole orthogonal time-of-flight hybrid instrument. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2009; 23:1941-1956. [PMID: 19496066 DOI: 10.1002/rcm.4091] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
In this study, we evaluated, by electrospray ionization mass spectrometry (ESI-MS) and collision-induced dissociation tandem mass spectrometry (CID-MS/MS) using a quadrupole orthogonal time-of-flight (QqToF)-MS/MS hybrid instrument, the gas-phase fragmentations of some commercially available biotinyl reagents. The biotin reagents used were: psoralen-BPE 1, p-diazobenzoyl biocytin (DBB) 2, photoreactive biotin 3, biotinyl-hexaethyleneglycol dimer 4, and the sulfo-SBED 5. The results showed that, during ESI-MS and CID-MS/MS analyses, the biotin reagents followed a similar gas-phase fragmentation pattern and the cleavages usually occurred at either end of the spacer arm of the biotin reagents. In general we have observed that the CID-MS/MS fragmentation routes of the five precursor protonated molecules obtained from the biotin linkers 1-5 afforded a series of product ions formed essentially by similar routes. The genesis and the structural identities of all the product ions obtained from the biotin linkers 1-5 have been assigned. All the exact mass assignments of the protonated molecules and the product ions were verified by conducting separate CID-MS/MS analysis of the deuterium-labelled precursor ions.
Collapse
Affiliation(s)
- Salim Sioud
- Department of Chemistry, Memorial University of Newfoundland, St. John's, Newfoundland, A1B 3V6, Canada
| | | | | | | | | |
Collapse
|
44
|
Emory JF, McLuckey SA. The role of amino acid composition in the charge inversion of deprotonated peptides via gas-phase ion/ion reactions. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2009; 20:180-187. [PMID: 18842425 DOI: 10.1016/j.jasms.2008.08.015] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2008] [Revised: 08/23/2008] [Accepted: 08/26/2008] [Indexed: 05/26/2023]
Abstract
Ion/ion charge inversion via multiple proton transfer reactions occurs via a long-lived intermediate. The intermediate can be observed if its lifetime is long relative to mechanisms for removal of excess energy (i.e., emission and collisional stabilization). The likelihood for formation of a stabilized intermediate is a function of characteristics of the reagent and analyte ions. This work is focused on the role acidic and basic sites of a deprotonated peptide play in the formation of a stabilized intermediate upon charge inversion with multiply protonated polypropyleniminediaminobutane dendrimers. A group of model peptides based on leucine enkephalin was used, which included YGGFL, YGGFLF, YGGFLK, YGGFLR and YGGFLH as well as methyl esterified and acetylated versions. Results showed that peptides containing basic amino acid residues charge inverted primarily by proton transfer from the DAB dendrimer to the peptide, whereas peptides without basic amino acids charge inverted primarily by complex formation with the DAB dendrimer. The modified versions of the peptides highlighted the importance of the presence of the C-terminus as well as the basicity of the peptide in the observation of a stabilized intermediate. These results provide new insights into the nature of the interactions that occur in the charge inversion of polypeptide anions via ion/ion reactions.
Collapse
Affiliation(s)
- Joshua F Emory
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907-1393, USA
| | | |
Collapse
|
45
|
Turner KB, Monti SA, Fabris D. Like polarity ion/ion reactions enable the investigation of specific metal interactions in nucleic acids and their noncovalent assemblies. J Am Chem Soc 2008; 130:13353-63. [PMID: 18785739 PMCID: PMC2654192 DOI: 10.1021/ja8045734] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A rare example of ion/ion reaction between species of like polarity was shown to take place during the transfer of metal cations from nucleic acid substrates to chelating agents in the gas phase. Gaseous anionic reactants were generated from separate solutions of analyte and chelator by using a dual nanospray setup. The respective multiply charged ions shared the same path and were allowed to react for a predetermined interval in an rf-only hexapole before high-resolution analysis by Fourier transform ion cyclotron resonance (FTICR) mass spectrometry. Efficient transfer of sodium and magnesium ions was readily observed with significant reduction of the nonspecific adducts that are typically associated with decreased sensitivity and resolution in the analysis of nucleic acid samples. Metal cations were abstracted from the initial analyte without being replaced by protons, in a process that was clearly dependent on the concentration of chelator in the auxiliary emitter and on the time spent by the reactants in the hexapole element. A survey of the properties of selected anionic chelators showed that their known affinity for a target cation in solution was more critical than their maximum anionic charge in determining the outcome of the transfer process. The analysis of selected assemblies requiring divalent cations to preserve their structural integrity and functional properties demonstrated that ion/ion reactions were clearly capable of discriminating between nonspecific interactions and specific coordination based on transfer susceptibility. These examples demonstrated that the ability to selectively eliminate nonspecific adducts in the gas phase, after the desolvation process is complete, offers a unique opportunity for studying specific metal binding in biological systems without resorting to separation procedures that may adversely affect the position of binding equilibria in solution and disrupt the assemblies under investigation.
Collapse
|
46
|
Polo LM, Limbach PA. Analysis of oligonucleotides by electrospray ionization mass spectrometry. ACTA ACUST UNITED AC 2008; Chapter 10:Unit 10.2. [PMID: 18428821 DOI: 10.1002/0471142700.nc1002s00] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Because of the high molecular weights and thermal lability of biomolecules such as nucleic acids and protein, they can be difficult to analyze by mass spectrometry. Such analyses require a "soft" ionization method that is capable of generating intact molecular ions. In addition, most mass analyzers have a limited upper mass range that is not sufficient for studying these large molecules. ESI-MS can be used to analyze molecules with a molecular weight that is larger than the mass-to-charge ratio limit of the analyzer. This unit describes how ESI allows for analysis of high-molecular-weight compounds through the generation of multiply charged ions in the gas phase. It discusses analyzer configurations, solvent selection, and gives protocols for sample preparation. For applications of ESI-MS, the unit discusses molecular weight determination and gives protocols for sequencing and for analyzing oligonucleotide modifications.
Collapse
Affiliation(s)
- L M Polo
- Louisiana State University, Baton Rouge, Louisiana, USA
| | | |
Collapse
|
47
|
On the use of different mass spectrometric techniques for characterization of sequence variability in genomic DNA. Anal Bioanal Chem 2008; 391:135-49. [DOI: 10.1007/s00216-008-1929-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2007] [Revised: 01/25/2008] [Accepted: 01/31/2008] [Indexed: 10/22/2022]
|
48
|
Shui-Ping Y, Yu-Fen Z, Xiu-Li H, Hua-Zheng L, Jian-Qiang L, Bin H, Huan-Wen C. Development of a Sonic Spray Ionization Source for the Mass Spectrometric Analysis of Proteins. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2008. [DOI: 10.1016/s1872-2040(08)60020-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
49
|
Forensic DNA fingerprinting by liquid chromatography-electrospray ionization mass spectrometry. Biotechniques 2007; 43:vii-xiii. [PMID: 18019345 DOI: 10.2144/000112581] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
The determination of the molecular mass of a DNA sequence has several benefits over conventional fragment-length analysis that are advantageous to the forensic field: (i) sequence variation is captured that increases the power of discrimination compared with that obtained by conventional fragment-length analysis. First experiments showed that this increase makes up to 20%-30% for STR analysis. The new technical approach does not invalidate established developments and data, but adds to this information with additional discriminative categories. (ii) ICEMS is faster and cheaper than electrophoresis, does not require internal size standards, allelic ladders, or spectral calibration, which are necessary for fluorescence-based electrophoresis. (iii) ICEMS can unequivocally detect any single sequence variation in DNA molecules with lengths up to 250 nucleotides. This allows for maximum discrimination of forensically relevant DNA fragments, covering all sorts of STRs, SNPs, and also the analysis of the hypervariable segments of mtDNA. More effort, however, needs to be put into software development that escorts the analysis and data interpretation processes to make this technology manageable for the practical user.
Collapse
|
50
|
Guo X, Liu Z, Liu S, Bentzley CM, Bruist MF. Structural features of the L-argininamide-binding DNA aptamer studied with ESI-FTMS. Anal Chem 2007; 78:7259-66. [PMID: 17037930 DOI: 10.1021/ac060606r] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The 24-mer DNA aptamer of Harada and Frankel (Harada, K.; Frankel, A. D. EMBO J. 1995, 14, 5798-5811) that binds L-argininamide (L-Arm) was studied by electrospray ionization Fourier transform mass spectrometry (ESI-FTMS). This DNA folds into a stem and loop such that the loop is able to engulf L-Arm. As controls, two derivatives of the same base composition, one with the same stem but a scrambled loop and the other with no ability to form a secondary structure, were studied. The two DNAs that could fold into stem-loop structures showed a more negatively charged distribution of ions than the linear control. This tendency was preserved in the presence of ligand; complexes expected to have more secondary structure had ions with more negative charges. Distinct species corresponding to no, one, and two bound L-Arm molecules were observed for each DNA. The fractional peak intensities were fit to a straightforward binding model and binding constants were obtained. Thus, ESI-FTMS can provide both qualitative and quantitative data regarding the structure of DNA and its interactions with noncovalent ligands.
Collapse
Affiliation(s)
- Xinhua Guo
- Green Chemistry and Process Laboratory, Changchun Center of Mass Spectrometry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P R China
| | | | | | | | | |
Collapse
|