1
|
Cucinotta FA. Review of NASA approach to space radiation risk assessments for Mars exploration. HEALTH PHYSICS 2015; 108:131-142. [PMID: 25551493 DOI: 10.1097/hp.0000000000000255] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Long duration space missions present unique radiation protection challenges due to the complexity of the space radiation environment, which includes high charge and energy particles and other highly ionizing radiation such as neutrons. Based on a recommendation by the National Council on Radiation Protection and Measurements, a 3% lifetime risk of exposure-induced death for cancer has been used as a basis for risk limitation by the National Aeronautics and Space Administration (NASA) for low-Earth orbit missions. NASA has developed a risk-based approach to radiation exposure limits that accounts for individual factors (age, gender, and smoking history) and assesses the uncertainties in risk estimates. New radiation quality factors with associated probability distribution functions to represent the quality factor's uncertainty have been developed based on track structure models and recent radiobiology data for high charge and energy particles. The current radiation dose limits are reviewed for spaceflight and the various qualitative and quantitative uncertainties that impact the risk of exposure-induced death estimates using the NASA Space Cancer Risk (NSCR) model. NSCR estimates of the number of "safe days" in deep space to be within exposure limits and risk estimates for a Mars exploration mission are described.
Collapse
Affiliation(s)
- Francis A Cucinotta
- *University of Nevada, Las Vegas. Department of Health Physics and Diagnostic Sciences, 4505 S. Maryland Parkway, Box 453037, Las Vegas NV, 89154-3037
| |
Collapse
|
2
|
A proposed integrated systems approach to the radiation biology of cosmic interest: biophysics and molecular characterization of tissues irradiated with 14 MeV neutrons. RENDICONTI LINCEI-SCIENZE FISICHE E NATURALI 2013. [DOI: 10.1007/s12210-013-0272-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
3
|
Zhou D, O'Sullivan D, Semones E, Zapp N, Benton E. Research on sensitivity fading of CR-39 detectors during long time exposure. RADIAT MEAS 2009. [DOI: 10.1016/j.radmeas.2009.09.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
4
|
|
5
|
Lodhi M, Diaz AB, Wilson TL. Simplified solar modulation model of inner trapped belt proton flux as a function of atmospheric density. RADIAT MEAS 2005. [DOI: 10.1016/j.radmeas.2004.10.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
6
|
Takada M, Baba M, Yamaguchi H, Fujitaka K. Differential absorbed dose distributions in lineal energy for neutrons and gamma rays at the mono-energetic neutron calibration facility. RADIATION PROTECTION DOSIMETRY 2005; 114:481-90. [PMID: 15914511 DOI: 10.1093/rpd/nch499] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Absorbed dose distributions in lineal energy for neutrons and gamma rays of mono-energetic neutron sources from 140 keV to 15 MeV were measured in the Fast Neutron Laboratory at Tohoku University. By using both a tissue-equivalent plastic walled counter and a graphite-walled low-pressure proportional counter, absorbed dose distributions in lineal energy for neutrons were obtained separately from those for gamma rays. This method needs no knowledge of energy spectra and dose distributions for gamma rays. The gamma-ray contribution in this neutron calibration field >1 MeV neutron was <3%, while for <550 keV it was >40%. The measured neutron absolute absorbed doses per unit neutron fluence agreed with the LA150 evaluated kerma factors. By using this method, absorbed dose distributions in lineal energy for neutrons and gamma rays in an unknown neutron field can be obtained separately.
Collapse
Affiliation(s)
- M Takada
- National Institute of Radiological Sciences, Chiba 263-8555, Japan
| | | | | | | |
Collapse
|
7
|
Miller J, Zeitlin C, Cucinotta FA, Heilbronn L, Stephens D, Wilson JW. Benchmark studies of the effectiveness of structural and internal materials as radiation shielding for the international space station. Radiat Res 2003; 159:381-90. [PMID: 12600241 DOI: 10.1667/0033-7587(2003)159[0381:bsoteo]2.0.co;2] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Accelerator-based measurements and model calculations have been used to study the heavy-ion radiation transport properties of materials in use on the International Space Station (ISS). Samples of the ISS aluminum outer hull were augmented with various configurations of internal wall material and polyethylene. The materials were bombarded with high-energy iron ions characteristic of a significant part of the galactic cosmic-ray (GCR) heavy-ion spectrum. Transmitted primary ions and charged fragments produced in nuclear collisions in the materials were measured near the beam axis, and a model was used to extrapolate from the data to lower beam energies and to a lighter ion. For the materials and ions studied, at incident particle energies from 1037 MeV/nucleon down to at least 600 MeV/nucleon, nuclear fragmentation reduces the average dose and dose equivalent per incident ion. At energies below 400 MeV/nucleon, the calculation predicts that as material is added, increased ionization energy loss produces increases in some dosimetric quantities. These limited results suggest that the addition of modest amounts of polyethylene or similar material to the interior of the ISS will reduce the dose to ISS crews from space radiation; however, the radiation transport properties of ISS materials should be evaluated with a realistic space radiation field.
Collapse
Affiliation(s)
- J Miller
- Lawrence Berkeley National Laboratory, University of California, Berkeley, California 94720, USA.
| | | | | | | | | | | |
Collapse
|
8
|
Uchihori Y, Fujitaka K, Yasuda N, Benton E. Intercomparison of radiation instruments for cosmic-ray with heavy ion beams at NIRS (ICCHIBAN project). JOURNAL OF RADIATION RESEARCH 2002; 43 Suppl:S81-S85. [PMID: 12793736 DOI: 10.1269/jrr.43.s81] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The first InterComparison for Cosmic-ray with Heavy Ion Beams At NIRS (ICCHIBAN) project is an ongoing, international collaboration organized at the National Institute of Radiological Sciences (NIRS), Japan, for the purpose of characterizing and comparing at a controlled, ground-based heavy ion facility the radiation response of instruments used aboard piloted spacecraft for crew and area dosimetry. We present preliminary results from the first set of ICCHIBAN exposures made at HIMAC heavy ion accelerator in February 2002. The initial series of exposures (1st ICCHIBAN run) was designed to establish the response of active detectors to two well-characterized heavy ion beams; 400 MeV/nucleon 12C and 400 MeV/nucleon 56Fe. These beams are representative in charge and energy of two of the most significant heavy ion components present in the galactic cosmic radiation spectrum. The properties of the incident beam, including intensity, profile, charge and total energy, were characterized using several different detector systems, including silicon detectors, CR-39 plastic nuclear track detectors and plastic scintillation counters. Once the response of each detector to heavy ion beams of known composition has been measured, results from on-orbit measurements made by the different instruments can be more meaningfully compared. We conclude by discussing plans for future ICCHIBAN runs, including next 2nd ICCHIBAN run for passive detectors in early summer 2002.
Collapse
Affiliation(s)
- Yukio Uchihori
- International Space Radiation Laboratory, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555, Japan.
| | | | | | | |
Collapse
|
9
|
Abstract
Radiation measurements made onboard the MIR Orbital Station have spanned nearly a decade and covered two solar cycles, including one of the largest solar particle events, one of the largest magnetic storms, and a mean solar radio flux level reaching 250 x 10(4) Jansky that has been observed in the last 40 years. The cosmonaut absorbed dose rates varied from about 450 microGy day-1 during solar minimum to approximately half this value during the last solar maximum. There is a factor of about two in dose rate within a given module, and a similar variation from module to module. The average radiation quality factor during solar minimum, using the ICRP-26 definition, was about 2.4. The drift of the South Atlantic Anomaly was measured to be 6.0 +/- 0.5 degrees W, and 1.6 +/- 0.5 degrees N. These measurements are of direct applicability to the International Space Station. This paper represents a comprehensive review of Mir Space Station radiation data available from a variety of sources.
Collapse
Affiliation(s)
- G D Badhwar
- NASA Johnson Space Center, Houston, TX 77058-3696, USA
| | | | | | | | | |
Collapse
|
10
|
Beaujean R, Kopp J, Burmeister S, Petersen F, Reitz G. Dosimetry inside MIR station using a silicon detector telescope (DOSTEL). RADIAT MEAS 2002; 35:433-8. [PMID: 12440435 DOI: 10.1016/s1350-4487(02)00074-4] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The dosimetry telescope (DOSTEL) was flown on the MIR orbital station during October 1997-January 1998. The mission average contributions to the absorbed dose rates (in water) were 126 +/- 4 microGy/d and 121 +/- 13 microGy/d for the GCR and the SAA component, respectively. The mean quality factors (ICRP60) deduced from the LET-spectra are 3.5 +/- 0.2 (GCR) and 1.3 +/- 0.1 (SAA). Separate LET spectra and temporal variations of the absorbed dose rates and of the mean quality factors are presented for these two radiation components as well as for solar energetic particles of the November 6, 1997 event.
Collapse
Affiliation(s)
- R Beaujean
- Institut fur Experimentelle und Angewandte Physik, Universitat Kiel, Kiel, Germany.
| | | | | | | | | |
Collapse
|
11
|
Gersey BB, Borak TB, Guetersloh SB, Zeitlin C, Miller J, Heilbronn L, Murakami T, Iwata Y. The response of a spherical tissue-equivalent proportional counter to iron particles from 200-1000 MeV/nucleon. Radiat Res 2002; 157:350-60. [PMID: 11839098 DOI: 10.1667/0033-7587(2002)157[0350:troast]2.0.co;2] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
The radiation environment on board the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. Iron-56 particles are considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPCs) are used as active dosimeters on manned space flights. These TEPCs are further used to determine the average quality factor for each space mission. A TEPC simulating a 1-microm-diameter sphere of tissue was exposed as part of a particle spectrometer to (56)Fe particles at energies from 200-1000 MeV/nucleon. The response of TEPCs in terms of mean lineal energy, y(F), and dose mean lineal energy, y(D), as well as the energy deposited at different impact parameters through the detector was determined for six different incident energies of (56)Fe particles in this energy range. Calculations determined that charged-particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using a radial dose distribution model, and the results were compared to experimental data.
Collapse
Affiliation(s)
- B B Gersey
- Department of Radiological Health Sciences, Colorado State University, Fort Collins, Colorado 80523, USA
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Shafirkin AV, Petrov VM, Kolomensky AV, Shurshakov VA. Lifetime total radiation risk of cosmonauts for orbital and interplanetary flights. ADVANCES IN SPACE RESEARCH : THE OFFICIAL JOURNAL OF THE COMMITTEE ON SPACE RESEARCH (COSPAR) 2002; 30:999-1003. [PMID: 12539777 DOI: 10.1016/s0273-1177(02)00162-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
This paper presents results of calculations of total radiation risk for cosmonauts over their lifetimes and assessments of possible shortening of life expectancy on the basis of generalized doses calculated for cosmonauts after a long term interplanetary and orbital space missions on "MIR" station and International Space Station with the use of mathematical expressions coming from a model of change mortality rate of mammals after irradiation. Tumor risk assessments for cosmonauts over lifetime after flights are also given. Dependences of the delayed radiation consequences mentioned above on flight duration, spacecraft shielding thicknesses, solar activity and cosmonauts' age are analyzed.
Collapse
Affiliation(s)
- A V Shafirkin
- State Research Centre of the RF-Institute for Biomedical Problems, Moscow, Russia
| | | | | | | |
Collapse
|
13
|
Abstract
The presence of a causal association between the frequency of chromosomal aberrations in peripheral blood lymphocytes and the risk of cancer has been substantiated recently by epidemiological studies. Cytogenetic analyses of crew members of the Mir Space Station have shown that a significant increase in the frequency of chromosomal aberrations can be detected after flight, and that such an increase is likely to be attributed to the radiation exposure. The risk of cancer can be estimated directly from the yields of chromosomal aberrations, taking into account some aspects of individual susceptibility and other factors unrelated to radiation. However, the use of an appropriate technique for the collection and analysis of chromosomes and the choice of the structural aberrations to be measured are crucial in providing sound results. Based on the fraction of aberrant lymphocytes detected before and after flight, the relative risk after a long-term Mir mission is estimated to be about 1.2-1.3. The new technique of mFISH can provide useful insights into the quantification of risk on an individual basis.
Collapse
Affiliation(s)
- M Durante
- Dipartimento di Scienze Fisiche, Università Federico II, Monte S. Angelo, Via Cintia, 80126 Napoli, Italy.
| | | | | | | |
Collapse
|
14
|
Doke T, Hayashi T, Borak TB. Comparisons of LET distributions measured in low-earth orbit using tissue-equivalent proportional counters and the position-sensitive silicon-detector telescope (RRMD-III). Radiat Res 2001; 156:310-6. [PMID: 11500140 DOI: 10.1667/0033-7587(2001)156[0310:coldmi]2.0.co;2] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Determinations of the LET distribution, phi(L), of charged particles within a spacecraft in low-Earth orbit have been made. One method used a cylindrical tissue-equivalent proportional counter (TEPC), with the assumption that for each measured event, lineal energy, y, is equal to LET and thus phi(L) = phi(y). The other was based on the direct measurement of LETs for individual particles using a charged-particle telescope consisting of position-sensitive silicon detectors called RRMD-III. There were differences of up to a factor of 10 between estimates of phi(L) using the two methods on the same mission. This caused estimates of quality factor to vary by a factor of two between the two methods.
Collapse
Affiliation(s)
- T Doke
- Tsukuba Space Center, National Space Development Agency of Japan, 2-1, Sengen-2 chome, Tsukuba-shi, Ibaraki-ken 305-8505, Japan.
| | | | | |
Collapse
|
15
|
Benton ER, Benton EV. Space radiation dosimetry in low-Earth orbit and beyond. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS 2001; 184:255-294. [PMID: 11863032 DOI: 10.1016/s0168-583x(01)00748-0] [Citation(s) in RCA: 162] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Space radiation dosimetry presents one of the greatest challenges in the discipline of radiation protection. This is a result of both the highly complex nature of the radiation fields encountered in low-Earth orbit (LEO) and interplanetary space and of the constraints imposed by spaceflight on instrument design. This paper reviews the sources and composition of the space radiation environment in LEO as well as beyond the Earth's magnetosphere. A review of much of the dosimetric data that have been gathered over the last four decades of human space flight is presented. The different factors affecting the radiation exposures of astronauts and cosmonauts aboard the International Space Station (ISS) are emphasized. Measurements made aboard the Mir Orbital Station have highlighted the importance of both secondary particle production within the structure of spacecraft and the effect of shielding on both crew dose and dose equivalent. Roughly half the dose on ISS is expected to come from trapped protons and half from galactic cosmic rays (GCRs). The dearth of neutron measurements aboard LEO spacecraft and the difficulty inherent in making such measurements have led to large uncertainties in estimates of the neutron contribution to total dose equivalent. Except for a limited number of measurements made aboard the Apollo lunar missions, no crew dosimetry has been conducted beyond the Earth's magnetosphere. At the present time we are forced to rely on model-based estimates of crew dose and dose equivalent when planning for interplanetary missions, such as a mission to Mars. While space crews in LEO are unlikely to exceed the exposure limits recommended by such groups as the NCRP, dose equivalents of the same order as the recommended limits are likely over the course of a human mission to Mars.
Collapse
Affiliation(s)
- E R Benton
- Eril Research, Inc., San Rafael, CA 94915-0788, USA.
| | | |
Collapse
|
16
|
Badhwar GD, O'Neill PM. Response of silicon-based linear energy transfer spectrometers: implication for radiation risk assessment in space flights. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT 2001; 466:464-474. [PMID: 11858255 DOI: 10.1016/s0168-9002(01)00285-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
There is considerable interest in developing silicon-based telescopes because of their compactness and low power requirements. Three such telescopes have been flown on board the Space Shuttle to measure the linear energy transfer spectra of trapped, galactic cosmic ray, and solar energetic particles. Dosimeters based on single silicon detectors have also been flown on the Mir orbital station. A comparison of the absorbed dose and radiation quality factors calculated from these telescopes with that estimated from measurements made with a tissue equivalent proportional counter show differences which need to be fully understood if these telescopes are to be used for astronaut radiation risk assessments. Instrument performance is complicated by a variety of factors. A Monte Carlo-based technique was developed to model the behavior of both single element detectors in a proton beam, and the performance of a two-element, wide-angle telescope, in the trapped belt proton field inside the Space Shuttle. The technique is based on: (1) radiation transport intranuclear-evaporation model that takes into account the charge and angular distribution of target fragments, (2) Landau-Vavilov distribution of energy deposition allowing for electron escape, (3) true detector geometry of the telescope, (4) coincidence and discriminator settings, (5) spacecraft shielding geometry, and (6) the external space radiation environment, including albedo protons. The value of such detailed modeling and its implications in astronaut risk assessment is addressed.
Collapse
Affiliation(s)
- G D Badhwar
- NASA Lyndon B. Johnson Space Center, Houston, TX 77058-3696, USA.
| | | |
Collapse
|
17
|
Doke T, Hayashi T, Kikuchi J, Sakaguchi T, Terasawa K, Yoshihira E, Nagaoka S, Nakano T, Takahashi S. Measurements of LET-distribution, dose equivalent and quality factor with the RRMD-III on the Space Shuttle Missions STS-84, -89 and -91. RADIAT MEAS 2001; 33:373-87. [PMID: 11855421 DOI: 10.1016/s1350-4487(00)00149-9] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Dosimetric measurements on the Space Shuttle Missions STS-84, -89 and -91 have been made by the real-time radiation monitoring device III (RRMD-III). Simultaneously, another dosimetry measurement was made by the Dosimetry Telescope (DOSTEL) on STS-84 and by the tissue-equivalent proportional counter (TEPC) on STS-91. First, the RRMD-III instrument is described in detail and its results summarized. Then, the results of DOSTEL and TEPC are compared with those of the RRMD-III. Also, the absorbed doses obtained by TLD (Mg2SiO4) and by RRMD-III on board STS-84 and -91 are compared.
Collapse
Affiliation(s)
- T Doke
- Advanced Research Institute for Science and Engineering, Waseda University, Kikui-cho-17, Shinjuku-ku, Tokyo 162-0044, Japan.
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Abstract
Human exposures to ionizing radiation have been vastly altered by developing technology in the last century. This has been most obvious in the development of radiation generating devices and the utilization of nuclear energy. But even air travel has had its impact on human exposure. Human exposure increases with advancing aircraft technology as a result of the higher operating altitudes reducing the protective cover provided by Earth's atmosphere from extraterrestrial radiations. This increase in operating altitudes is taken to a limit by human operations in space. Less obvious is the changing character of the radiations at higher altitudes. The associated health risks are less understood with increasing altitude due to the increasing complexity and new field components found in high-altitude and space operations.
Collapse
Affiliation(s)
- J W Wilson
- Materials Division, NASA Langley Research Center, Hampton, VA 23681-0001, USA.
| |
Collapse
|
19
|
Doke T, Hayashi T, Kikuchi J, Nagaoka S, Nakano T, Sakaguchi T, Terasawa K, Badhwar GD. Application of real-time radiation dosimetry using a new silicon LET sensor. Mutat Res 1999; 430:191-202. [PMID: 10631333 DOI: 10.1016/s0027-5107(99)00130-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A new type of real-time radiation monitoring device, RRMD-III, consisting of three double-sided silicon strip detectors (DSSDs), has been developed and tested on-board the Space Shuttle mission STS-84. The test succeeded in measuring the linear energy transfer (LET) distribution over the range of 0.2 keV/micrometer to 600 keV/micrometer for 178 h. The Shuttle cruised at an altitude of 300 to 400 km and an inclination angle of 51.6 degrees for 221.3 h, which is equivalent to the International Space Station orbit. The LET distribution obtained for particles was investigated by separating it into galactic cosmic ray (GCR) particles and trapped particles in the South Atlantic Anomaly (SAA) region. The result shows that the contribution in dose-equivalent due to GCR particles is almost equal to that from trapped particles. The total absorbed dose rate during the mission was 0.611 mGy/day; the effective quality factor, 1.64; and the dose equivalent rate, 0.998 mSv/day. The average absorbed dose rates are 0.158 mGy/min for GCR particles and 3.67 mGy/min for trapped particles. The effective quality factors are 2.48 for GCR particles and 1.19 for trapped particles. The absorbed doses obtained by the RRMD-III and a conventional method using TLD (Mg(2)SiO(4)), which was placed around the RRMD-III were compared. It was found that the TLDs showed a lower efficiency, just 58% of absorbed dose registered by the RRMD-III.
Collapse
Affiliation(s)
- T Doke
- Advanced Research Institute for Science and Engineering, Waseda University, Okubo 4-3-1, Shinjuku-ku, Tokyo, Japan.
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Abstract
Spaceflight exposes astronaut crews to natural ionizing radiation. To date, exposures in manned spaceflight have been well below the career limits recommended to NASA by the National Council of Radiation Protection and Measurements (NCRP). This will not be the case for long-duration exploratory class missions. Additionally. International Space Station (ISS) crews will receive higher doses than earlier flight crews. Uncertainties in our understanding of long-term bioeffects, as well as updated analyses of the Hiroshima. Nagasaki and Chernobyl tumorigenesis data, have prompted the NCRP to recommend further reductions by 30-50% for career dose limit guidelines. Intelligent spacecraft design and material selection can provide a shielding strategy capable of maintaining crew exposures within recommended guidelines. Current studies on newer radioprotectant compounds may find combinations of agents which further diminish the risk of radiation-induced bioeffects to the crew.
Collapse
Affiliation(s)
- M Stanford
- Center of Aerospace Medicine and Physiology, University of Texas Medical Branch at Galveston 77555, USA
| | | |
Collapse
|
21
|
Badhwar GD, Atwell W, Cash B, Petrov VM, Tchernykh IV, Shurshakov VA, Arkhangelsky VA. Radiation environment on the Mir orbital station during solar minimum. ADVANCES IN SPACE RESEARCH : THE OFFICIAL JOURNAL OF THE COMMITTEE ON SPACE RESEARCH (COSPAR) 1998; 22:501-510. [PMID: 11542778 DOI: 10.1016/s0273-1177(98)01070-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The Mir station has been in a 51.65 degrees inclination orbit since March 1986. In March 1995, the first US astronaut flew on the Mir-18 mission and returned on the Space Shuttle in July 1995. Since then three additional US astronauts have stayed on orbit for up to 6 months. Since the return of the first US astronaut, both the Spektr and Priroda modules have docked with Mir station, altering the mass shielding distribution. Radiation measurements, including the direct comparison of US and Russian absorbed dose rates in the Base Block of the Mir station, were made during the Mir-18 and -19 missions. There is a significant variation of dose rates across the core module; the six locations sampled showed a variation of a factor of nearly two. A tissue equivalent proportional counter (TEPC) measured a total absorbed dose rate of 300 microGy/day, roughly equally divided between the rate due to trapped protons from the South Atlantic Anomaly (SAA) and galactic cosmic radiation (GCR). This dose rate is about a factor of two lower than the rate measured by the thinly shielded (0.5 g cm-2 of Al) operational ion chamber (R-16), and about 3/2 of the rate of the more heavily shielded (3.5 g cm-2 of Al) ion chamber. This is due to the differences in the mass shielding properties at the location of these detectors. A comparison of integral linear energy transfer (LET) spectra measured by TEPC and plastic nuclear track detectors (PNTDs) deployed side by side are in remarkable agreement in the LET region of 15-1000 keV/micrometer, where the PNTDs are fully efficient. The average quality factor, using the ICRP-26 definition, was 2.6, which is higher than normally used. There is excellent agreement between the measured GCR dose rate and model calculations, but this is not true for trapped protons. The measured Mir-18 crew skin dose equivalent rate was 1133 microSv/day. Using the skin dose rate and anatomical models, we have estimated the blood-forming organ (BFO) dose rate and the maximum stay time in orbit for International Space Station crew members.
Collapse
Affiliation(s)
- G D Badhwar
- NASA Johnson Space Center, Houston, Texas 77058-3696, USA
| | | | | | | | | | | | | |
Collapse
|
22
|
Schraube H, Leuthold G, Roesler S, Heinrich W. Neutron spectra at flight altitudes and their radiological estimation. ADVANCES IN SPACE RESEARCH : THE OFFICIAL JOURNAL OF THE COMMITTEE ON SPACE RESEARCH (COSPAR) 1998; 21:1727-1738. [PMID: 11542892 DOI: 10.1016/s0273-1177(98)00059-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Since the publication of the ICRP-report 60, air crews and other frequently flying persons are considered as occupationally exposed people. At civil flight levels neutrons contribute the major part to the radiologically relevant dose to men. The quantification of the neutron dose, and herewith the radiation risk due to neutrons, suffers from spectral data available especially in the energy range above 20 MeV. Experimental data were recently obtained at a low flight level on top of the mountain Zugspitze at 3000m using a modified Bonner sphere spectrometer. The resulting spectra are compared with Monte-Carlo transport calculations from top of the atmosphere down to 700 g/cm2. These data and others from the literature are used to calculate operational and risk related quantities, i.e. ambient dose equivalent and effective dose.
Collapse
Affiliation(s)
- H Schraube
- GSF-Forschungszentrum, Institut fur Strahlenschutz, Neuherberg, Germany
| | | | | | | |
Collapse
|
23
|
Sakaguchi T, Doke T, Hayashi T, Kikuchi J, Hasebe N, Kashiwagi T, Takashima T, Takahashi K, Nakano T, Nagaoka S, Takahashi S, Yamanaka H, Yamaguchi K, Badhwar GD. Radiation dosimetry measurements with real time radiation monitoring device (RRMD)-II in Space Shuttle STS-79. JAPANESE JOURNAL OF APPLIED PHYSICS 1997; 36:7453-7459. [PMID: 11542403 DOI: 10.1143/jjap.36.7453] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The real-time measurement of radiation environment was made with an improved real-time radiation monitoring device (RRMD)-II onboard Space Shuttle STS-79 (S/MM#4: 4th Shuttle MIR Mission, at an inclination angle of 51.6 degrees and an altitude of 250-400km) for 199 h during 17-25 September, 1996. The observation of the detector covered the linear energy transfer (LET) range of 3.5-6000 keV/micrometer. The Shuttle orbital profile in this mission was equivalent to that of the currently planned Space Station, and provided an opportunity to investigate variations in count rate and dose equivalent rate depending on altitude, longitude, and latitude in detail. Particle count rate and dose equivalent rate were mapped geographically during the mission. Based on the map of count rate, an analysis was made by dividing whole region into three regions: South Atlantic Anomaly (SAA) region, high latitude region and other regions. The averaged absorbed dose rate during the mission was 39.3 microGy/day for a LET range of 3.5-6000 keV/micrometer. The corresponding average dose equivalent rates during the mission are estimated to be 293 microSv/day with quality factors from International Commission on Radiological Protection (ICRP)-Pub. 60 and 270 microSv/day with quality factors from ICRP-Pub. 26. The effective quality factors for ICRP-Pub. 60 and 26 are 7.45 and 6.88, respectively. From the present data for particles of LET > 3.5keV/micrometer, we conclude that the average dose equivalent rate is dominated by the contribution of galactic cosmic ray (GCR) particles. The dose-detector depth dependence was also investigated.
Collapse
Affiliation(s)
- T Sakaguchi
- Advanced Research Institute for Science and Engineering, Waseda University, Tokyo, Japan.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Badhwar GD, Shurshakov VA, Tsetlin VV. Solar modulation of dose rate onboard the Mir station. IEEE TRANSACTIONS ON NUCLEAR SCIENCE 1997; 44:2529-2541. [PMID: 11542263 DOI: 10.1109/23.650860] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Models of the radiation belts that are currently used to estimate exposure for astronauts describe the environment at times of either solar minimum or solar maximum. Static models, constructed using data acquired prior to 1970 during a solar cycle with relatively low solar radio flux, have flux uncertainties of a factor of two to live and dose-rate uncertainties of a factor of about two. The inability of these static models to provide a dynamic description of the radiation belt environment limits our ability to predict radiation exposures for long-duration missions in low earth orbits. In an attempt to add some predictive capability of these models, we studied the measured daily absorbed dose rate on the Mir orbital station over roughly the complete 22nd solar cycle that saw some of the highest solar flux values in the last 40 y. We show that the daily trapped particle dose rate is an approximate power law function of daily atmospheric density. Atmospheric density values are in turn obtained from standard correlation with observed solar radio noise flux. This correlation improves, particularly during periods of high solar activity, if the density at roughly 400 days earlier time is used. This study suggests the possibility of a dose- and flux-predictive trapped-belt model based on atmospheric density.
Collapse
Affiliation(s)
- G D Badhwar
- NASA Johnson Space Center, Houston, TX 77058-3696, USA.
| | | | | |
Collapse
|
25
|
Badhwar GD, Atwell W, Cash B, Weyland M, Petrov VM, Tchernykh IV, Shurshakov VA, Arkhangelsky VV, Kushin VV, Klyachin NA, Benton EV, Frank AL, Benton ER, Frigo LA, Dudkin VE, Vana N, Schoner W, Fugger M. Intercomparison of radiation measurements on STS-63. RADIAT MEAS 1996; 26:901-16. [PMID: 11540523 DOI: 10.1016/s1350-4487(96)00082-0] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
A joint NASA Russia study of the radiation environment inside the Space Shuttle was performed on STS-63. This was the second flight under the Shuttle-Mir Science Program (Phase 1). The Shuttle was launched on 2 February 1995, in a 51.65 degrees inclination orbit and landed at Kennedy Space Center on 11 February 1995, for a total flight duration of 8.27 days. The Shuttle carried a complement of both passive and active detectors distributed throughout the Shuttle volume. The crew exposure varied from 1962 to 2790 microGy with an average of 2265.8 microGy or 273.98 microGy/day. Crew exposures varied by a factor of 1.4, which is higher than usual for STS mission. The flight altitude varied from 314 to 395 km and provided a unique opportunity to obtain dose variation with altitude. Measurements of the average east-west dose variation were made using two active solid state detectors. The dose rate in the Spacehab locker, measured using a tissue equivalent proportional counter (TEPC), was 413.3 microGy/day, consistent with measurements made using thermoluminescent detectors (TLDs) in the same locker. The average quality factor was 2.33, and although it was higher than model calculations, it was consistent with values derived from high temperature peaks in TLDs. The dose rate due to galactic cosmic radiation was 110.6 microGy/day and agreed with model calculations. The dose rate from trapped particles was 302.7 microGy/day, nearly a factor of 2 lower than the prediction of the AP8 model. The neutrons in the intermediate energy range of 1-20 MeV contributed 13 microGy/day and 156 microSv/day, respectively. Analysis of data from the charged particle spectrometer has not yet been completed.
Collapse
Affiliation(s)
- G D Badhwar
- NASA Johnson Space Center, Houston, TX 77058-3696, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Abstract
Four experiments utilizing passive detectors (P0006, P0004, A0015, M0004) were flown on LDEF to study the radiation environment. These experiments have been summarized in a companion paper (Benton et al., 1996). One of the experimental goals was to measure LET spectra at different locations and shielding depths with plastic nuclear track detectors (PNTD). It was found that the LET spectra extended well above the LET cutoff imposed by the geomagnetic field on GCR particle penetration into LEO. The high LET particles detected were mostly short-range (range < 2000 m), indicating that they were secondaries produced locally within the PNTD. The presence of these high LET particle fluences is important for the determination of dose equivalent because of the high Quality Factors (Q) involved. A relatively small fraction of particle fluence can contribute a large fraction of dose equivalent. Short-range, inelastic secondary particles produced by trapped protons in the South Atlantic Anomaly (SAA) were found to be a major contributor to the LET spectra above 100 keV/micrometer. The LET spectra were found to extend beyond the approximately 137 keV/micrometer relativistic GCR Fe peak to over 1000 keV/micrometer. The high LET tail of the LET spectra was measured in CR-39 and polycarbonate PNTDs using different techniques. GCR made a relatively modest contribution to the LET spectra as compared to the contributions from short-range secondary particles and stopping protons. LET spectra intercomparisons were made between LDEF measurements and exposures to 154 MeV accelerated proton beams. The similarities support the role of nuclear interactions by trapped protons as the major source of secondary particles in the PNTDs. Also techniques were employed to reduce the range cutoff for detection of the short-range secondaries to approximately 1 micrometer, so that essentially all secondary particles were included in the LET spectra. This has allowed a more realistic assessment of secondary contribution to dose equivalent. Comparisons of measured and calculated LET spectra have been made that demonstrate the need for more accurate modeling of secondary particles in radiation transport codes. Comparisons include preliminary calculations in which attempts have been made to include secondary particles.
Collapse
Affiliation(s)
- E R Benton
- Eril Research Inc., San Rafael, CA 94915-0788, USA
| | | | | | | | | |
Collapse
|
27
|
Nefedov N, Csige I, Benton EV, Frank AL, Frigo LA, Benton ER. Particle directionality and trapped proton fluences on LDEF. RADIAT MEAS 1996; 26:881-7. [PMID: 11540520 DOI: 10.1016/s1350-4487(96)00099-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Directionality of incident space radiation is a significant factor in spacecraft shielding and astronaut dosimetry in low Earth orbit (LEO). Particle directionality of GCR and trapped protons were measured on LDEF with plastic nuclear track detectors (PNTD) from the P0006 west-side experiment. This experiment consisted of a thick detector stack and is described more fully in a companion article (Benton et al., 1996). The anisotropy of the trapped protons produced maximum intensity for protons arriving from the west. The fluences of the eastward directed trapped protons have been measured by selection of the particles on the basis of range in the PNTDs. The measured fluences are compared with the model calculations of Armstrong and Colborn (1993).
Collapse
Affiliation(s)
- N Nefedov
- Physics Research Laboratory, University of San Francisco, CA 94117-1080, USA
| | | | | | | | | | | |
Collapse
|