1
|
Fluorescent Immunoassay for Determination of Staphylococcal Enterotoxin A in Milk by Immobilized F(ab')2 Fragment of Anti-enterotoxin A Monoclonal Antibody. FOOD ANAL METHOD 2021. [DOI: 10.1007/s12161-021-02019-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
2
|
Becheva ZR, Atanasova MK, Ivanov YL, Godjevargova TI. Magnetic Nanoparticle-Based Fluorescence Immunoassay for Determination of Ochratoxin A in Milk. FOOD ANAL METHOD 2020. [DOI: 10.1007/s12161-020-01848-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
3
|
Ohyama Y, Nakajima K, Renfrow MB, Novak J, Takahashi K. Mass spectrometry for the identification and analysis of highly complex glycosylation of therapeutic or pathogenic proteins. Expert Rev Proteomics 2020; 17:275-296. [PMID: 32406805 DOI: 10.1080/14789450.2020.1769479] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
INTRODUCTION Protein glycosylation influences characteristics such as folding, stability, protein interactions, and solubility. Therefore, glycan moieties of therapeutic proteins and proteins that are likely associated with disease pathogenesis should be analyzed in-depth, including glycan heterogeneity and modification sites. Recent advances in analytical methods and instrumentation have enabled comprehensive characterization of highly complex glycosylated proteins. AREA COVERED The following aspects should be considered when analyzing glycosylated proteins: sample preparation, chromatographic separation, mass spectrometry (MS) and fragmentation methods, and bioinformatics, such as software solutions for data analyses. Notably, analysis of glycoproteins with heavily sialylated glycans or multiple glycosylation sites requires special considerations. Here, we discuss recent methodological advances in MS that provide detailed characterization of heterogeneous glycoproteins. EXPERT OPINION As characterization of complex glycosylated proteins is still analytically challenging, the function or pathophysiological significance of these proteins is not fully understood. To reproducibly produce desired forms of therapeutic glycoproteins or to fully elucidate disease-specific patterns of protein glycosylation, a highly reproducible and robust analytical platform(s) should be established. In addition to advances in MS instrumentation, optimization of analytical and bioinformatics methods and utilization of glycoprotein/glycopeptide standards is desirable. Ultimately, we envision that an automated high-throughput MS analysis will provide additional power to clinical studies and precision medicine.
Collapse
Affiliation(s)
- Yukako Ohyama
- Department of Nephrology, Fujita Health University School of Medicine , Toyoake, Japan.,Department of Biomedical Molecular Sciences, Fujita Health University School of Medicine , Toyoake, Japan
| | - Kazuki Nakajima
- Center for Research Promotion and Support, Fujita Health University , Toyoake, Japan
| | - Matthew B Renfrow
- Departments of Biochemistry and Molecular Genetics and Microbiology, University of Alabama at Birmingham , Birmingham, AL, USA
| | - Jan Novak
- Departments of Biochemistry and Molecular Genetics and Microbiology, University of Alabama at Birmingham , Birmingham, AL, USA
| | - Kazuo Takahashi
- Department of Nephrology, Fujita Health University School of Medicine , Toyoake, Japan.,Department of Biomedical Molecular Sciences, Fujita Health University School of Medicine , Toyoake, Japan.,Departments of Biochemistry and Molecular Genetics and Microbiology, University of Alabama at Birmingham , Birmingham, AL, USA
| |
Collapse
|
4
|
Glycan Analysis as Biomarkers for Testicular Cancer. Diagnostics (Basel) 2019; 9:diagnostics9040156. [PMID: 31652641 PMCID: PMC6963830 DOI: 10.3390/diagnostics9040156] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Revised: 10/13/2019] [Accepted: 10/19/2019] [Indexed: 12/24/2022] Open
Abstract
The U.S. Preventive Services Task Force does not recommend routine screening for testicular cancer (TC) in asymptomatic men, essentially because serological testicular cancer (TC) biomarkers are not reliable. The main reason is that two of the most important TC biomarkers, α-fetoprotein (AFP) and human chorionic gonadotropin (hCG), are not produced solely due to TC. Moreover, up to 40% of patients with TC do not have elevated serological biomarkers, which is why serial imaging with CT is the chief means of monitoring progress. On the other hand, exposure to radiation can lead to an increased risk of secondary malignancies. This review provides the first comprehensive account of the applicability of protein glycoprofiling as a promising biomarker for TC with applications in disease diagnostics, monitoring and recurrence evaluation. The review first deals with the description and classification of TC. Secondly, the limitations of current TC biomarkers such as hCG, AFP and lactate dehydrogenase are provided together with an extensive overview of the glycosylation of hCG and AFP related to TC. The final part of the review summarises the potential of glycan changes on either hCG and AFP as TC biomarkers for diagnostics and prognostics purposes, and for disease recurrence evaluation. Finally, an analysis of glycans in serum and tissues as TC biomarkers is also provided.
Collapse
|
5
|
Dąbrowski M, Zimińska A, Kalecki J, Cieplak M, Lisowski W, Maksym R, Shao S, D'Souza F, Kuhn A, Sharma PS. Facile Fabrication of Surface-Imprinted Macroporous Films for Chemosensing of Human Chorionic Gonadotropin Hormone. ACS APPLIED MATERIALS & INTERFACES 2019; 11:9265-9276. [PMID: 30714713 DOI: 10.1021/acsami.8b17951] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
We present an improved approach for the preparation of highly selective and homogeneous molecular cavities in molecularly imprinted polymers (MIPs) via the combination of surface imprinting and semi-covalent imprinting. Toward that, first, a colloidal crystal mold was prepared via the Langmuir-Blodgett (LB) technique. Then, human chorionic gonadotropin (hCG) template protein was immobilized on the colloidal crystal mold. Later, hCG derivatization with electroactive functional monomers via amide chemistry was performed. In a final step, optimized potentiostatic polymerization of 2,3'-bithiophene enabled depositing an MIP film as the macroporous structure. This synergistic strategy resulted in the formation of molecularly imprinted cavities exclusively on the internal surface of the macropores, which were accessible after dissolution of silica molds. The recognition of hCG by the macroporous MIP film was transduced with the help of electric transducers, namely, extended-gate field-effect transistors (EG-FET) and capacitive impedimetry (CI). These readout strategies offered the ability to create chemosensors for the label-free determination of the hCG hormone. Other than the simple confirmation of pregnancy, hCG assay is a common tool for the diagnosis and follow-up of ectopic pregnancy or trophoblast tumors. Concentration measurements with these EG-FET and CI-based devices allowed real-time measurements of hCG in the range of 0.8-50 and 0.17-2.0 fM, respectively, in 10 mM carbonate buffer (pH = 10). Moreover, the selectivity of chemosensors with respect to protein interferences was very high.
Collapse
Affiliation(s)
- Marcin Dąbrowski
- Institute of Physical Chemistry , Polish Academy of Sciences , Kasprzaka 44/52 , 01-224 Warsaw , Poland
| | - Agnieszka Zimińska
- Institute of Physical Chemistry , Polish Academy of Sciences , Kasprzaka 44/52 , 01-224 Warsaw , Poland
- Department of Biomaterials Chemistry, Faculty of Pharmacy with Laboratory Medicine Division , Medical University of Warsaw , Banacha 1 , 02-097 Warsaw , Poland
| | - Jakub Kalecki
- Institute of Physical Chemistry , Polish Academy of Sciences , Kasprzaka 44/52 , 01-224 Warsaw , Poland
| | - Maciej Cieplak
- Institute of Physical Chemistry , Polish Academy of Sciences , Kasprzaka 44/52 , 01-224 Warsaw , Poland
| | - Wojciech Lisowski
- Institute of Physical Chemistry , Polish Academy of Sciences , Kasprzaka 44/52 , 01-224 Warsaw , Poland
| | - Radosław Maksym
- Department of Reproductive Health, Center of Postgraduate Medical Education , St. Sophia Hospital , Zelazna 90 , 01-004 Warsaw , Poland
| | - Shuai Shao
- Department of Chemistry , University of North Texas , 1155 Union Circle No. 305070 , Denton , Texas 76203-5017 , United States
| | - Francis D'Souza
- Department of Chemistry , University of North Texas , 1155 Union Circle No. 305070 , Denton , Texas 76203-5017 , United States
| | - Alexander Kuhn
- University of Bordeaux, CNRS UMR 5255, Bordeaux INP, ENSCBP , 16 Avenue Pey Berland , 33607 Pessac , France
| | - Piyush S Sharma
- Institute of Physical Chemistry , Polish Academy of Sciences , Kasprzaka 44/52 , 01-224 Warsaw , Poland
| |
Collapse
|
6
|
Jalal UM, Jin GJ, Eom KS, Kim MH, Shim JS. On-chip signal amplification of magnetic bead-based immunoassay by aviating magnetic bead chains. Bioelectrochemistry 2017; 122:221-226. [PMID: 29129601 DOI: 10.1016/j.bioelechem.2017.11.001] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2017] [Revised: 11/02/2017] [Accepted: 11/02/2017] [Indexed: 02/07/2023]
Abstract
In this work, a Lab-on-a-Chip (LOC) platform is used to electromagnetically actuate magnetic bead chains for an enhanced immunoassay. Custom-made electromagnets generate a magnetic field to form, rotate, lift and lower the magnetic bead chains (MBCs). The cost-effective, disposable LOC platform was made with a polymer substrate and an on-chip electrochemical sensor patterned via the screen-printing process. The movement of the MBCs is controlled to improve the electrochemical signal up to 230% when detecting beta-type human chorionic gonadotropin (β-hCG). Thus, the proposed on-chip MBC-based immunoassay is applicable for rapid, qualitative electrochemical point-of-care (POC) analysis.
Collapse
Affiliation(s)
- Uddin M Jalal
- Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, Kwangwoon University, Seoul, Republic of Korea
| | - Gyeong Jun Jin
- Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, Kwangwoon University, Seoul, Republic of Korea
| | - Kyu Shik Eom
- Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, Kwangwoon University, Seoul, Republic of Korea
| | - Min Ho Kim
- Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, Kwangwoon University, Seoul, Republic of Korea
| | - Joon S Shim
- Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, Kwangwoon University, Seoul, Republic of Korea.
| |
Collapse
|
7
|
A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip. PLoS One 2015; 10:e0137891. [PMID: 26368287 PMCID: PMC4569379 DOI: 10.1371/journal.pone.0137891] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2015] [Accepted: 08/24/2015] [Indexed: 01/03/2023] Open
Abstract
Human chorionic gonadotropin (hCG), a glycoprotein hormone secreted from the placenta, is a key molecule that indicates pregnancy. Here, we have designed a cost-effective, label-free, in situ point-of-care (POC) immunosensor to estimate hCG using a cuneated 25 nm polysilicon nanogap electrode. A tiny chip with the dimensions of 20.5 × 12.5 mm was fabricated using conventional lithography and size expansion techniques. Furthermore, the sensing surface was functionalized by (3-aminopropyl)triethoxysilane and quantitatively measured the variations in hCG levels from clinically obtained human urine samples. The dielectric properties of the present sensor are shown with a capacitance above 40 nF for samples from pregnant women; it was lower with samples from non-pregnant women. Furthermore, it has been proven that our sensor has a wide linear range of detection, as a sensitivity of 835.88 μA mIU-1 ml-2 cm-2 was attained, and the detection limit was 0.28 mIU/ml (27.78 pg/ml). The dissociation constant Kd of the specific antigen binding to the anti-hCG was calculated as 2.23 ± 0.66 mIU, and the maximum number of binding sites per antigen was Bmax = 22.54 ± 1.46 mIU. The sensing system shown here, with a narrow nanogap, is suitable for high-throughput POC diagnosis, and a single injection can obtain triplicate data or parallel analyses of different targets.
Collapse
|
8
|
Tang H, Hsueh P, Kletter D, Bern M, Haab B. The detection and discovery of glycan motifs in biological samples using lectins and antibodies: new methods and opportunities. Adv Cancer Res 2015; 126:167-202. [PMID: 25727148 DOI: 10.1016/bs.acr.2014.11.003] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Recent research has uncovered unexpected ways that glycans contribute to biology, as well as new strategies for combatting disease using approaches involving glycans. To make full use of glycans for clinical applications, we need more detailed information on the location, nature, and dynamics of glycan expression in vivo. Such studies require the use of specimens acquired directly from patients. Effective studies of clinical specimens require low-volume assays, high precision measurements, and the ability to process many samples. Assays using affinity reagents-lectins and glycan-binding antibodies-can meet these requirements, but further developments are needed to make the methods routine and effective. Recent advances in the use of glycan-binding proteins involve improved determination of specificity using glycan arrays; the availability of databases for mining and analyzing glycan array data; lectin engineering methods; and the ability to quantitatively interpret lectin measurements. Here, we describe many of the challenges and opportunities involved in the application of these new approaches to the study of biological samples. The new tools hold promise for developing methods to improve the outcomes of patients afflicted with diseases characterized by aberrant glycan expression.
Collapse
Affiliation(s)
- Huiyuan Tang
- Van Andel Research Institute, Grand Rapids, MI, USA
| | - Peter Hsueh
- Van Andel Research Institute, Grand Rapids, MI, USA
| | | | | | - Brian Haab
- Van Andel Research Institute, Grand Rapids, MI, USA.
| |
Collapse
|
9
|
Hoofnagle AN, Wener MH. The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry. J Immunol Methods 2009; 347:3-11. [PMID: 19538965 PMCID: PMC2720067 DOI: 10.1016/j.jim.2009.06.003] [Citation(s) in RCA: 412] [Impact Index Per Article: 25.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2009] [Revised: 05/21/2009] [Accepted: 06/05/2009] [Indexed: 12/26/2022]
Abstract
Immunoassays have made it possible to measure dozens of individual proteins and other analytes in human samples for help in establishing the diagnosis and prognosis of disease. In too many cases the results of those measurements are misleading and can lead to unnecessary treatment or missed opportunities for therapeutic interventions. These cases stem from problems inherent to immunoassays performed with human samples, which include a lack of concordance across platforms, autoantibodies, anti-reagent antibodies, and the high-dose hook effect. Tandem mass spectrometry may represent a detection method capable of alleviating many of the flaws inherent to immunoassays. We review our understanding of the problems associated with immunoassays on human specimens and describe methodologies using tandem mass spectrometry that could solve some of those problems. We also provide a critical discussion of the potential pitfalls of novel mass spectrometric approaches in the clinical laboratory.
Collapse
Affiliation(s)
- Andrew N Hoofnagle
- Department of Laboratory Medicine, University of Washington, Seattle, WA 98195, USA.
| | | |
Collapse
|
10
|
|
11
|
Abstract
Antibody arrays can be employed for the profiling glycan structures on proteins. Antibody arrays capture multiple, specific proteins directly from biological samples (such as serum), and lectin and glycan-binding antibodies probe the levels of specific glycans on the captured proteins. We use a practical method of partitioning microscope slides to enable the convenient processing of many detection reagents or samples. A critical first step in the procedure is the chemical derivatization of the glycans on the spotted capture antibodies, which prevents lectin binding to those glycans. We describe those methods along with the methods for preparing and treating serum samples, running the experiments, and designing and interpreting the experiments.
Collapse
|
12
|
Kelly LS, Birken S, Puett D. Determination of hyperglycosylated human chorionic gonadotropin produced by malignant gestational trophoblastic neoplasias and male germ cell tumors using a lectin-based immunoassay and surface plasmon resonance. Mol Cell Endocrinol 2007; 260-262:33-9. [PMID: 17081681 PMCID: PMC1847626 DOI: 10.1016/j.mce.2006.05.010] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2005] [Accepted: 05/12/2006] [Indexed: 11/16/2022]
Abstract
The ability to reliably detect aberrant glycosylation of human chorionic gonadotropin (hCG) may have profound implications for the diagnosis and monitoring of malignant gestational trophoblastic neoplasia, germ cell tumors, other malignancies, and pregnancy complications. To become a clinically useful assay, however, this discrimination of glycoforms should be possible on minimally treated biological specimens. Towards this end, we have developed a lectin-based sandwich-type immunoassay to compare the glycosylation patterns of hCG among urine specimens from patients presenting with a normal pregnancy, invasive mole, choriocarcinoma, and male germ cell tumors using carbohydrate-free antibody fragments as capture reagents and a panel of eight lectins, five recognizing neutral sugars and three recognizing sialic acid. There was no significant difference in the binding of any of the lectins to hCG in the urine of women over the gestational range of 6-38 weeks. Three lectins, however, exhibited differential binding to urinary hCG derived from these normal pregnant controls and that from patients with malignant forms of gestational trophoblastic disease and male germ cell tumors. Galanthus nivalis agglutinin and Maackia amurensis lectin, which bind terminal mannose and alpha(2-3)sialic acid, respectively, preferentially bound pregnancy-derived hCG, whereas the lectin, wheat germ agglutinin, which binds sialic acid and beta(1-4)N-acetylglucosamine, exhibited decreased binding to pregnancy-derived hCG compared to that from patients with male germ cell tumors and malignant gestational trophoblastic neoplasia. The differential binding observed with these three promising lectins is most encouraging and warrants further examination. The experimental paradigm also holds promise for the development of comparable assays for other glycosylated tumor markers.
Collapse
Affiliation(s)
- Lisa S Kelly
- Department of Biochemistry and Molecular Biology, University of Georgia, Athens, GA, United States
| | | | | |
Collapse
|
13
|
Abstract
We identified 1113 articles (103 reviews, 1010 primary research articles) published in 2005 that describe experiments performed using commercially available optical biosensors. While this number of publications is impressive, we find that the quality of the biosensor work in these articles is often pretty poor. It is a little disappointing that there appears to be only a small set of researchers who know how to properly perform, analyze, and present biosensor data. To help focus the field, we spotlight work published by 10 research groups that exemplify the quality of data one should expect to see from a biosensor experiment. Also, in an effort to raise awareness of the common problems in the biosensor field, we provide side-by-side examples of good and bad data sets from the 2005 literature.
Collapse
Affiliation(s)
- Rebecca L Rich
- Center for Biomolecular Interaction Analysis, University of Utah, Salt Lake City, UT 84132, USA
| | | |
Collapse
|