1
|
Joshi A, Vishnu G K A, Sakorikar T, Kamal AM, Vaidya JS, Pandya HJ. Recent advances in biosensing approaches for point-of-care breast cancer diagnostics: challenges and future prospects. NANOSCALE ADVANCES 2021; 3:5542-5564. [PMID: 36133274 PMCID: PMC9417675 DOI: 10.1039/d1na00453k] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Accepted: 08/12/2021] [Indexed: 05/12/2023]
Abstract
Timely and accurate diagnosis of breast cancer is essential for efficient treatment and the best possible survival rates. Biosensors have emerged as a smart diagnostic platform for the detection of biomarkers specific to the onset, recurrence, and therapeutic drug monitoring of breast cancer. There have been exciting recent developments, including significant improvements in the validation, sensitivity, specificity, and integration of sample processing steps to develop point-of-care (POC) integrated micro-total analysis systems for clinical settings. The present review highlights various biosensing modalities (electrical, optical, piezoelectric, mass, and acoustic sensing). It provides deep insights into their design principles, signal amplification strategies, and comparative performance analysis. Finally, this review emphasizes the status of existing integrated micro-total analysis systems (μ-TAS) for personalized breast cancer therapeutics and associated challenges and outlines the approach required to realize their successful translation into clinical settings.
Collapse
Affiliation(s)
- Anju Joshi
- Department of Electronic Systems Engineering, Division of EECS, Indian Institute of Science Bangalore India
| | - Anil Vishnu G K
- Department of Electronic Systems Engineering, Division of EECS, Indian Institute of Science Bangalore India
- Centre for BioSystems Science and Engineering, Indian Institute of Science Bangalore India
| | - Tushar Sakorikar
- Department of Electronic Systems Engineering, Division of EECS, Indian Institute of Science Bangalore India
| | - Arif M Kamal
- Department of Electronic Systems Engineering, Division of EECS, Indian Institute of Science Bangalore India
| | - Jayant S Vaidya
- Division of Surgery and Interventional Science, University College London 4919 London UK
| | - Hardik J Pandya
- Department of Electronic Systems Engineering, Division of EECS, Indian Institute of Science Bangalore India
| |
Collapse
|
2
|
Yuan Z, Wang L, Chen J, Su W, Li A, Su G, Liu P, Zhou X. Electrochemical strategies for the detection of cTnI. Analyst 2021; 146:5474-5495. [PMID: 34515706 DOI: 10.1039/d1an00808k] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Acute myocardial infarction (AMI) is the main cause of death from cardiovascular diseases. Thus, early diagnosis of AMI is essential for the treatment of irreversible damage from myocardial infarction. Traditional electrocardiograms (ECG) cannot meet the specific detection of AMI. Cardiac troponin I (cTnI) is the main biomarker for the diagnosis of myocardial infarction, and the detection of cTnI content has become particularly important. In this review, we introduced and compared the advantages and disadvantages of various cTnI detection methods. We focused on the analysis and comparison of the main indicators and limitations of various cTnI biosensors, including the detection range, detection limit, specificity, repeatability, and stability. In particular, we pay more attention to the application and development of electrochemical biosensors in the diagnosis of cardiovascular diseases based on different biological components. The application of electrochemical microfluidic chips for cTnI was also briefly introduced in this review. Finally, this review also briefly discusses the unresolved challenges of electrochemical detection and the expectations for improvement in the detection of cTnI biosensing in the future.
Collapse
Affiliation(s)
- Zhipeng Yuan
- Advanced Micro and Nano-instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China. .,Shandong Institute of Mechanical Design and Research, Jinan 250353, China
| | - Li Wang
- Advanced Micro and Nano-instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China. .,Shandong Institute of Mechanical Design and Research, Jinan 250353, China
| | - Jun Chen
- Advanced Micro and Nano-instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China. .,Shandong Institute of Mechanical Design and Research, Jinan 250353, China
| | - Weiguang Su
- Advanced Micro and Nano-instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China. .,Shandong Institute of Mechanical Design and Research, Jinan 250353, China
| | - Anqing Li
- Advanced Micro and Nano-instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China. .,Shandong Institute of Mechanical Design and Research, Jinan 250353, China
| | - Guosheng Su
- Advanced Micro and Nano-instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China. .,Shandong Institute of Mechanical Design and Research, Jinan 250353, China
| | - Pengbo Liu
- Advanced Micro and Nano-instruments Center, School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China. .,Shandong Institute of Mechanical Design and Research, Jinan 250353, China
| | | |
Collapse
|
3
|
Taskin MB, Ahmad T, Wistlich L, Meinel L, Schmitz M, Rossi A, Groll J. Bioactive Electrospun Fibers: Fabrication Strategies and a Critical Review of Surface-Sensitive Characterization and Quantification. Chem Rev 2021; 121:11194-11237. [DOI: 10.1021/acs.chemrev.0c00816] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Mehmet Berat Taskin
- Department of Functional Materials in Medicine and Dentistry and Bavarian Polymer Institute, University of Würzburg, 97070 Würzburg, Germany
| | - Taufiq Ahmad
- Department of Functional Materials in Medicine and Dentistry and Bavarian Polymer Institute, University of Würzburg, 97070 Würzburg, Germany
| | - Laura Wistlich
- Department of Functional Materials in Medicine and Dentistry and Bavarian Polymer Institute, University of Würzburg, 97070 Würzburg, Germany
| | - Lorenz Meinel
- Institute of Pharmacy and Food Chemistry and Helmholtz Institute for RNA Based Infection Research, 97074 Würzburg, Germany
| | - Michael Schmitz
- Department of Functional Materials in Medicine and Dentistry and Bavarian Polymer Institute, University of Würzburg, 97070 Würzburg, Germany
| | - Angela Rossi
- Department of Functional Materials in Medicine and Dentistry and Bavarian Polymer Institute, University of Würzburg, 97070 Würzburg, Germany
| | - Jürgen Groll
- Department of Functional Materials in Medicine and Dentistry and Bavarian Polymer Institute, University of Würzburg, 97070 Würzburg, Germany
| |
Collapse
|
4
|
Parmin NA, Hashim U, Gopinath SCB, Nadzirah S, Rejali Z, Afzan A, Uda MNA. Human Papillomavirus E6 biosensing: Current progression on early detection strategies for cervical Cancer. Int J Biol Macromol 2018; 126:877-890. [PMID: 30597241 DOI: 10.1016/j.ijbiomac.2018.12.235] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2018] [Revised: 11/20/2018] [Accepted: 12/25/2018] [Indexed: 01/22/2023]
Abstract
Prognosis of early cancer detection becomes one of the tremendous issues in the medical health system. Medical debates among specialist doctor and researcher in therapeutic approaches became a hot concern for cervix cancer deficiencies early screening, risk factors cross-reaction, portability device, rapid and free labeling system. The electrical biosensing based system showed credibility in higher specificity and selectivity due to hybridization of DNA duplex between analyte target and DNA probes. Electrical DNA sensor for cervix cancer has attracted too many attentions to researcher notification based on high performance, easy to handle, rapid system and possible to miniaturize. This review explores the current progression and future insignificant for HPV E6 genobiosensing for early Detection Strategies of Cervical Cancer.
Collapse
Affiliation(s)
- N A Parmin
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia; School of Bioprocess Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
| | - Uda Hashim
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia; School of Microelectronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia
| | - Subash C B Gopinath
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia; School of Bioprocess Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia
| | - S Nadzirah
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia
| | - Zulida Rejali
- Department of Obstetrics and Gynaecology (O&G), Faculty of Medicine & Health Sciences, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia
| | - Amilia Afzan
- Department of Obstetrics and Gynaecology (O&G), Faculty of Medicine & Health Sciences, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia
| | - M N A Uda
- School of Bioprocess Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia
| |
Collapse
|
5
|
Kozitsina AN, Svalova TS, Malysheva NN, Okhokhonin AV, Vidrevich MB, Brainina KZ. Sensors Based on Bio and Biomimetic Receptors in Medical Diagnostic, Environment, and Food Analysis. BIOSENSORS 2018; 8:E35. [PMID: 29614784 PMCID: PMC6022999 DOI: 10.3390/bios8020035] [Citation(s) in RCA: 61] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Revised: 03/29/2018] [Accepted: 03/29/2018] [Indexed: 01/09/2023]
Abstract
Analytical chemistry is now developing mainly in two areas: automation and the creation of complexes that allow, on the one hand, for simultaneously analyzing a large number of samples without the participation of an operator, and on the other, the development of portable miniature devices for personalized medicine and the monitoring of a human habitat. The sensor devices, the great majority of which are biosensors and chemical sensors, perform the role of the latter. That last line is considered in the proposed review. Attention is paid to transducers, receptors, techniques of immobilization of the receptor layer on the transducer surface, processes of signal generation and detection, and methods for increasing sensitivity and accuracy. The features of sensors based on synthetic receptors and additional components (aptamers, molecular imprinted polymers, biomimetics) are discussed. Examples of bio- and chemical sensors' application are given. Miniaturization paths, new power supply means, and wearable and printed sensors are described. Progress in this area opens a revolutionary era in the development of methods of on-site and in-situ monitoring, that is, paving the way from the "test-tube to the smartphone".
Collapse
Affiliation(s)
- Alisa N Kozitsina
- Department of Analytical Chemistry, Institute of Chemical Engineering, Ural Federal University named after the first President of Russia B.N. Yeltsin, 620002 Yekaterinburg, Russia.
| | - Tatiana S Svalova
- Department of Analytical Chemistry, Institute of Chemical Engineering, Ural Federal University named after the first President of Russia B.N. Yeltsin, 620002 Yekaterinburg, Russia.
| | - Natalia N Malysheva
- Department of Analytical Chemistry, Institute of Chemical Engineering, Ural Federal University named after the first President of Russia B.N. Yeltsin, 620002 Yekaterinburg, Russia.
| | - Andrei V Okhokhonin
- Department of Analytical Chemistry, Institute of Chemical Engineering, Ural Federal University named after the first President of Russia B.N. Yeltsin, 620002 Yekaterinburg, Russia.
| | - Marina B Vidrevich
- Scientific and Innovation Center for Sensory Technologies, Ural State University of Economics, 620144 Yekaterinburg, Russia.
| | - Khiena Z Brainina
- Department of Analytical Chemistry, Institute of Chemical Engineering, Ural Federal University named after the first President of Russia B.N. Yeltsin, 620002 Yekaterinburg, Russia.
- Scientific and Innovation Center for Sensory Technologies, Ural State University of Economics, 620144 Yekaterinburg, Russia.
| |
Collapse
|
6
|
Electrochemical immunoassay for detection of prostate specific antigen based on peptide nanotube-gold nanoparticle-polyaniline immobilized pencil graphite electrode. J Colloid Interface Sci 2018; 510:318-326. [DOI: 10.1016/j.jcis.2017.09.079] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2017] [Revised: 09/19/2017] [Accepted: 09/21/2017] [Indexed: 01/24/2023]
|
7
|
Arya SK, Zhurauski P, Jolly P, Batistuti MR, Mulato M, Estrela P. Capacitive aptasensor based on interdigitated electrode for breast cancer detection in undiluted human serum. Biosens Bioelectron 2017; 102:106-112. [PMID: 29127898 DOI: 10.1016/j.bios.2017.11.013] [Citation(s) in RCA: 83] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2017] [Revised: 10/17/2017] [Accepted: 11/01/2017] [Indexed: 01/07/2023]
Abstract
We report the development of a simple and powerful capacitive aptasensor for the detection and estimation of human epidermal growth factor receptor 2 (HER2), a biomarker for breast cancer, in undiluted serum. The study involves the incorporation of interdigitated gold electrodes, which were used to prepare the electrochemical platform. A thiol terminated DNA aptamer with affinity for HER2 was used to prepare the bio-recognition layer via self-assembly on interdigitated gold surfaces. Non-specific binding was prevented by blocking free spaces on surface via starting block phosphate buffer saline-tween20 blocker. The sensor was characterized using cyclic voltammetry, electrochemical impedance spectroscopy (EIS), atomic force microscopy and contact angle studies. Non-Faradic EIS measurements were utilized to investigate the sensor performance via monitoring of the changes in capacitance. The aptasensor exhibited logarithmically detection of HER2 from 1pM to 100nM in both buffer and undiluted serum with limits of detection lower than 1pM. The results pave the way to develop other aptamer-based biosensors for protein biomarkers detection in undiluted serum.
Collapse
Affiliation(s)
- Sunil K Arya
- Department of Electronic & Electrical Engineering, University of Bath, Bath BA2 7AY, United Kingdom.
| | - Pavel Zhurauski
- Department of Electronic & Electrical Engineering, University of Bath, Bath BA2 7AY, United Kingdom
| | - Pawan Jolly
- Department of Electronic & Electrical Engineering, University of Bath, Bath BA2 7AY, United Kingdom
| | - Marina R Batistuti
- Department of Physics, University of São Paulo, 14040-901 Ribeirão Preto, SP, Brazil
| | - Marcelo Mulato
- Department of Physics, University of São Paulo, 14040-901 Ribeirão Preto, SP, Brazil
| | - Pedro Estrela
- Department of Electronic & Electrical Engineering, University of Bath, Bath BA2 7AY, United Kingdom.
| |
Collapse
|
8
|
Abstract
Resonant and acoustic wave devices have been researched for several decades for application in the gravimetric sensing of a variety of biological and chemical analytes. These devices operate by coupling the measurand (e.g. analyte adsorption) as a modulation in the physical properties of the acoustic wave (e.g. resonant frequency, acoustic velocity, dissipation) that can then be correlated with the amount of adsorbed analyte. These devices can also be miniaturized with advantages in terms of cost, size and scalability, as well as potential additional features including integration with microfluidics and electronics, scaled sensitivities associated with smaller dimensions and higher operational frequencies, the ability to multiplex detection across arrays of hundreds of devices embedded in a single chip, increased throughput and the ability to interrogate a wider range of modes including within the same device. Additionally, device fabrication is often compatible with semiconductor volume batch manufacturing techniques enabling cost scalability and a high degree of precision and reproducibility in the manufacturing process. Integration with microfluidics handling also enables suitable sample pre-processing/separation/purification/amplification steps that could improve selectivity and the overall signal-to-noise ratio. Three device types are reviewed here: (i) bulk acoustic wave sensors, (ii) surface acoustic wave sensors, and (iii) micro/nano-electromechanical system (MEMS/NEMS) sensors.
Collapse
|
9
|
Zhang Y, Yang F, Sun Z, Li YT, Zhang GJ. A surface acoustic wave biosensor synergizing DNA-mediated in situ silver nanoparticle growth for a highly specific and signal-amplified nucleic acid assay. Analyst 2017; 142:3468-3476. [DOI: 10.1039/c7an00988g] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
An SAW biosensor harmonizes the surface mass effect for signal-amplified and sequence-specific DNA detection in blood serum.
Collapse
Affiliation(s)
- Yulin Zhang
- School of Laboratory Medicine
- Hubei University of Chinese Medicine
- Wuhan 430065
- China
| | - Fan Yang
- School of Laboratory Medicine
- Hubei University of Chinese Medicine
- Wuhan 430065
- China
| | - Zhongyue Sun
- School of Laboratory Medicine
- Hubei University of Chinese Medicine
- Wuhan 430065
- China
| | - Yu-Tao Li
- School of Laboratory Medicine
- Hubei University of Chinese Medicine
- Wuhan 430065
- China
| | - Guo-Jun Zhang
- School of Laboratory Medicine
- Hubei University of Chinese Medicine
- Wuhan 430065
- China
| |
Collapse
|
10
|
Jayanthi VSPKSA, Das AB, Saxena U. Recent advances in biosensor development for the detection of cancer biomarkers. Biosens Bioelectron 2016; 91:15-23. [PMID: 27984706 DOI: 10.1016/j.bios.2016.12.014] [Citation(s) in RCA: 286] [Impact Index Per Article: 31.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Revised: 11/24/2016] [Accepted: 12/07/2016] [Indexed: 02/08/2023]
Abstract
Cancer is the second largest disease throughout the world with an increasing mortality rate over the past few years. The patient's survival rate is uncertain due to the limitations of cancer diagnosis and therapy. Early diagnosis of cancer is decisive for its successful treatment. A biomarker-based cancer diagnosis may significantly improve the early diagnosis and subsequent treatment. Biosensors play a crucial role in the detection of biomarkers as they are easy to use, portable, and can do analysis in real time. This review describes various biosensors designed for detecting nucleic acid and protein-based cancer biomarkers for cancer diagnosis. It mainly lays emphasis on different approaches to use electrochemical, optical, and mass-based transduction systems in cancer biomarker detection. It also highlights the analytical performances of various biosensor designs concerning cancer biomarkers in detail.
Collapse
Affiliation(s)
| | - Asim Bikas Das
- Department of Biotechnology, National Institute of Technology Warangal, Warangal 506004, Telangana, India
| | - Urmila Saxena
- Department of Biotechnology, National Institute of Technology Warangal, Warangal 506004, Telangana, India.
| |
Collapse
|
11
|
Fourati N, Seydou M, Zerrouki C, Singh A, Samanta S, Maurel F, Aswal DK, Chehimi M. Ultrasensitive and selective detection of dopamine using cobalt-phthalocyanine nanopillar-based surface acoustic wave sensor. ACS APPLIED MATERIALS & INTERFACES 2014; 6:22378-22386. [PMID: 25412427 DOI: 10.1021/am506403f] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A highly selective and sensitive surface acoustic wave (SAW) sensor of dopamine (DA) was developed by depositing cobalt phthalocyanine (CoPc) nanopillars on gold-coated sensing platform of SAW sensor. The developed biosensor presents a sensitivity of 1.6°/nM, has a low limit of detection (LOD) on the order of 0.1 nM, and imparts more selectivity toward DA, since the detection limit of the interfering ascorbic acid (AA) is as high as 1 mM. To understand the selectivity mechanisms of this sensor toward DA, density functional theory-based chemical calculations were carried out. Calculations suggest two different types of interactions: dative bond with a very strong character for DA-CoPc complexes, and significant ionic character in the case of AA-CoPc ones. The interaction energies, in liquid phase, were estimated to be equal to -81 kJ mol(-1) and -38 kJ mol(-1) for DA-CoPc and AA-CoPc complexes, respectively, therefore accounting for the selective detection of DA over AA using tandem CoPc nanopillar-based SAW sensor device. This work demonstrates a simple and efficient design of SAW sensors employing thin nanostructured CoPc biomolecular recognition layers for DA detection.
Collapse
Affiliation(s)
- Najla Fourati
- CNRS-ENS Cachan-Cnam, SATIE, UMR 8029 , 292 rue Saint Martin, 75003 Paris, France
| | | | | | | | | | | | | | | |
Collapse
|