1
|
Iaboni M, Crivellin F, Arena F, La Cava F, Cordaro A, Stummo F, Faletto D, Huet S, Candela L, Pedrault J, Zanella ER, Bertotti A, Blasi F, Maiocchi A, Poggi L, Reitano E. Complete preclinical evaluation of the novel antibody mimetic Nanofitin-IRDye800CW for diverse non-invasive diagnostic applications in the management of HER-2 positive tumors. Sci Rep 2025; 15:9832. [PMID: 40118987 PMCID: PMC11928573 DOI: 10.1038/s41598-025-93696-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2024] [Accepted: 03/10/2025] [Indexed: 03/24/2025] Open
Abstract
There are well-known limitations associated to the use of antibodies in the non-invasive detection of HER-2 expression. In fact, current procedures recommended for diagnostic purposes of HER-2 status are still invasive techniques. Here, a novel, smaller diagnostic probe, the anti-HER-2 Nanofitin conjugated to the fluorophore IRDye800CW (NF-800), underwent an in vitro/in vivo proof of concept study by Optical Imaging. NF-800 showed high affinity and specificity for the cellular target, and the ability to internalize into HER-2 positive cells. By ex vivo analysis, NF-800 showed a selective tumor accumulation in xenograft tumor models, and also a good tumor targeting efficacy in translational preclinical setups, such as orthotopic and patient-derived xenograft (PDX) models. In the latter, NF-800 was compared to the anti-HER-2 antibody Trastuzumab, displaying a large diagnostic advantage. Interestingly, NF-800 did not seem to share the same binding site with Trastuzumab and Pertuzumab, opening specific theragnostic opportunities for NF-800 in combination with standard-of-care antibodies.
Collapse
Affiliation(s)
- Margherita Iaboni
- Bracco Research Centre, Bracco Imaging Spa, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy.
| | - Federico Crivellin
- Bracco Research Centre, Bracco Imaging Spa, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy
| | - Francesca Arena
- Bracco Research Centre, Bracco Imaging Spa, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy
| | - Francesca La Cava
- Bracco Research Centre, Bracco Imaging Spa, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy
| | - Alessia Cordaro
- Bracco Research Centre, Bracco Imaging Spa, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy
| | - Francesco Stummo
- Bracco Research Centre, Bracco Imaging Spa, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy
| | - Daniele Faletto
- Bracco Research Centre, Bracco Imaging Spa, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy
| | - Simon Huet
- Affilogic SAS, 24 Rue de La Rainière, 44300, Nantes, France
| | - Leo Candela
- Affilogic SAS, 24 Rue de La Rainière, 44300, Nantes, France
| | - Jessy Pedrault
- Affilogic SAS, 24 Rue de La Rainière, 44300, Nantes, France
| | - Eugenia R Zanella
- Candiolo Cancer Institute - FPO IRCCS, Strada Provinciale 142, 10060, Candiolo, Turin, Italy
| | - Andrea Bertotti
- Candiolo Cancer Institute - FPO IRCCS, Strada Provinciale 142, 10060, Candiolo, Turin, Italy
- Department of Oncology, University of Turin, Candiolo, Turin, Italy
| | - Francesco Blasi
- Bracco Research Centre, Bracco Imaging Spa, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy
| | - Alessandro Maiocchi
- Bracco Research Centre, Bracco Imaging Spa, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy
| | - Luisa Poggi
- Bracco Research Centre, Bracco Imaging Spa, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy
| | - Erika Reitano
- Bracco Research Centre, Bracco Imaging Spa, Via Ribes 5, 10010, Colleretto Giacosa, Turin, Italy
| |
Collapse
|
2
|
Feng Y, Pannem S, Hodge S, Rounds C, Tichauer KM, Paulsen KD, Samkoe KS. Quantitative pharmacokinetic and biodistribution studies for fluorescent imaging agents. BIOMEDICAL OPTICS EXPRESS 2024; 15:1861-1877. [PMID: 38495714 PMCID: PMC10942698 DOI: 10.1364/boe.504878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 12/02/2023] [Accepted: 01/22/2024] [Indexed: 03/19/2024]
Abstract
Pharmacokinetics and biodistribution studies are essential for characterizing fluorescent agents in vivo. However, few simple methods based on fluorescence imaging are available that account for tissue optical properties and sample volume differences. We describe a method for simultaneously quantifying mean fluorescence intensity of whole blood and homogenized tissues in glass capillary tubes for two fluorescent agents, ABY-029 and IRDye 680LT, using wide-field imaging and tissue-specific calibration curves. All calibration curves demonstrated a high degree of linearity with mean R2 = 0.99 ± 0.01 and RMSE = 0.12 ± 0.04. However, differences between linear regressions indicate that tissue-specific calibration curves are required for accurate concentration recovery. The lower limit of quantification (LLOQ) for all samples tested was determined to be < 0.3 nM for ABY-029 and < 0.4 nM for IRDye 680LT.
Collapse
Affiliation(s)
- Yichen Feng
- Geisel School of Medicine, Dartmouth College, 1 Rope Ferry Road, Hanover, NH 03755, USA
| | - Sanjana Pannem
- Thayer School of Engineering, Dartmouth College, 15 Thayer Drive, Hanover, NH 03755, USA
| | - Sassan Hodge
- Thayer School of Engineering, Dartmouth College, 15 Thayer Drive, Hanover, NH 03755, USA
| | - Cody Rounds
- Department of Biomedical Engineering, Illinois Institute of Technology, 10 West 35 Street, Chicago, IL 60616, USA
| | - Kenneth M. Tichauer
- Department of Biomedical Engineering, Illinois Institute of Technology, 10 West 35 Street, Chicago, IL 60616, USA
| | - Keith D. Paulsen
- Thayer School of Engineering, Dartmouth College, 15 Thayer Drive, Hanover, NH 03755, USA
| | - Kimberley S. Samkoe
- Geisel School of Medicine, Dartmouth College, 1 Rope Ferry Road, Hanover, NH 03755, USA
- Thayer School of Engineering, Dartmouth College, 15 Thayer Drive, Hanover, NH 03755, USA
| |
Collapse
|