1
|
Yan LKQ, Tam SK, Ng KM. A numerical platform for predicting the performance of paper-based analytical devices. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:7888-7897. [PMID: 39431348 DOI: 10.1039/d4ay01305k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2024]
Abstract
This article presents a numerical platform for predicting the performance of paper-based analytical devices. The capillary flow, reaction, dissolution, and other physicochemical phenomena associated with device operation are accounted for using Darcy's law, Richard's equation and other transport equations. The platform can be used for different paper substrates, biorecognition methods, detection systems (such as optical and electrochemical detection), device patterns and dimensions, and ways in which the device is operated such as the input method of the body fluid. The device performance is quantified using indicators such as assay time, signal strength and product cost. The predictive capability of this numerical tool is verified with devices reported in the literature. It is shown that the platform can be used to identify possible improvements to these existing devices. More importantly, it can also serve as a numerical tool for synthesizing new paper-based analytical devices with minimum experimental effort.
Collapse
Affiliation(s)
- Lawrence K Q Yan
- Dept. of Chemical and Biological Engineering, The Hong Kong University of Science and Technology Clear Water Bay, Hong Kong.
| | - Sze Kee Tam
- Dept. of Chemical and Biological Engineering, The Hong Kong University of Science and Technology Clear Water Bay, Hong Kong.
| | - Ka Ming Ng
- Dept. of Chemical and Biological Engineering, The Hong Kong University of Science and Technology Clear Water Bay, Hong Kong.
| |
Collapse
|
2
|
Leelasattarathkul T, Trakoolwilaiwan T, Khachornsakkul K. A gold nanomaterial-integrated distance-based analytical device for uric acid quantification in human urine samples. Analyst 2024; 149:5518-5526. [PMID: 39420824 DOI: 10.1039/d4an01139b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2024]
Abstract
In this article, we present the first demonstration of a distance-based paper analytical device (dPAD) for uric acid quantification in human urine samples with instrument-free readout and user-friendliness for the rapid diagnosis and prognosis of various related diseases. By employing gold nanoparticles (AuNPs) as a peroxidase-like nanozyme, our proposed technique eliminates the utilization of horseradish peroxidase (HRP), making the device cost-effective and stable. In our dPAD, uric acid in the sample is oxidized by the uricase enzyme and subsequently catalysed with AuNPs in the sample zone, generating hydroxyl radicals (˙OH). Then, the produced ˙OH reacts with 3,3'-diaminobenzidine (DAB) to form poly DAB (oxDAB), resulting in a coloured distance signal in the detection zone of the dPAD. The variation of the distance of the observed red-brown colour is directly proportional to the uric acid concentration. Our sensor exhibited a linear range from 0.50 to 6.0 mmol L-1 (R2 = 0.9922) with a detection limit (LOD) of 0.25 mmol L-1, covering the clinical range of uric acid in urine. Hence, there is no need for additional sample preparation or dilution. Additionally, this assay is highly selective, with no interferences. We also found that this approach could accurately and precisely determine uric acid in human control samples with the recovery ranging from 99.37 to 100.35 with the highest RSD of 4.05%. Our method is comparable with the use of a commercially available uric acid sensor at a 95% confidence interval. Consequently, the developed dPAD offers numerous advantages such as cost-effectiveness, simplicity, and ease of operation with unskilled individuals. Furthermore, this concept can be applied for extensive biosensing applications in monitoring other biomarkers as an alternative analytical point-of-care (POC) device.
Collapse
Affiliation(s)
- Tapparath Leelasattarathkul
- Division of Chemistry, Department of Science, Faculty of Science and Technology, Rajamangala University of Technology Krungthep, Bangkok, 10120 Thailand.
| | - Thithawat Trakoolwilaiwan
- Division of Chemistry, Department of Science, Faculty of Science and Technology, Rajamangala University of Technology Krungthep, Bangkok, 10120 Thailand.
- National Nanotechnology Center (NANOTEC), National Science and Technology Development Agency (NSTDA), Khlong Luang, Pathum Thani, 12120 Thailand
| | - Kawin Khachornsakkul
- Division of Chemistry, Department of Science, Faculty of Science and Technology, Rajamangala University of Technology Krungthep, Bangkok, 10120 Thailand.
- Department of Electrical and Computer Engineering, Tufts University, Medford, MA 02155, USA
| |
Collapse
|
3
|
Khachornsakkul K, Del-Rio-Ruiz R, Chheang L, Zeng W, Sonkusale S. Distance-based paper analytical device for multiplexed quantification of cytokine biomarkers using carbon dots integrated with molecularly imprinted polymer. LAB ON A CHIP 2024; 24:2262-2271. [PMID: 38501606 DOI: 10.1039/d4lc00055b] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/20/2024]
Abstract
This article introduces distance-based paper analytical devices (dPADs) integrated with molecularly imprinted polymers (MIPs) and carbon dots (CDs) for simultaneous quantification of cytokine biomarkers, namely C-reactive protein (CRP), tumor necrosis factor-alpha (TNF-α), and interleukin-6 (IL-6) in human biological samples for diagnosis of cytokine syndrome. Using fluorescent CDs and MIP technology, the dPAD exhibits high selectivity and sensitivity. Detection is based on fluorescence quenching of CDs achieved through the interaction of the target analytes with the MIP layer on the paper substrate. Quantitative analysis is easily accomplished by measuring the distance length of quenched fluorescence with a traditional ruler and naked eye readout enabling rapid diagnosis of cytokine syndrome and the underlying infection. Our sensor demonstrated linear ranges of 2.50-24.0 pg mL-1 (R2 = 0.9974), 0.25-3.20 pg mL-1 (R2 = 0.9985), and 1.50-16.0 pg mL-1 (R2 = 0.9966) with detection limits (LODs) of 2.50, 0.25, and 1.50 pg mL-1 for CRP, TNF-α, and IL-6, respectively. This sensor also demonstrated remarkable selectivity compared to a sensor employing a non-imprinted polymer (NIP), and precision with the highest relative standard deviation (RSD) of 5.14%. The sensor is more accessible compared to prior methods relying on expensive reagents and instruments and complex fabrication methods. Furthermore, the assay provided notable accuracy for monitoring these biomarkers in various human samples with recovery percentages ranging between 99.22% and 103.58%. By integrating microfluidic systems, nanosensing, and MIPs technology, our developed dPADs hold significant potential as a cost-effective and user-friendly analytical method for point-of-care diagnostics (POC) of cytokine-related disorders. This concept can be further extended to developing diagnostic devices for other biomarkers.
Collapse
Affiliation(s)
- Kawin Khachornsakkul
- Department of Electrical and Computer Engineering, Tufts University, Medford, MA 02155, USA.
- Nano Lab, Tufts University, Medford, MA 02155, USA
| | - Ruben Del-Rio-Ruiz
- Department of Electrical and Computer Engineering, Tufts University, Medford, MA 02155, USA.
- Nano Lab, Tufts University, Medford, MA 02155, USA
| | - Lita Chheang
- Department of Electrical and Computer Engineering, Tufts University, Medford, MA 02155, USA.
- Nano Lab, Tufts University, Medford, MA 02155, USA
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Bangkok 10140, Thailand
| | - Wenxin Zeng
- Department of Electrical and Computer Engineering, Tufts University, Medford, MA 02155, USA.
- Nano Lab, Tufts University, Medford, MA 02155, USA
| | - Sameer Sonkusale
- Department of Electrical and Computer Engineering, Tufts University, Medford, MA 02155, USA.
- Nano Lab, Tufts University, Medford, MA 02155, USA
| |
Collapse
|
4
|
Kótai L, Lázár K, Kiss LF, Szentmihályi K. Reaction of Partially Methylated Polygalacturonic Acid with Iron(III) Chloride and Characterization of a New Mixed Chloride-Polygalacturonate Complex. Molecules 2024; 29:890. [PMID: 38398642 PMCID: PMC10893460 DOI: 10.3390/molecules29040890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2024] [Revised: 02/06/2024] [Accepted: 02/15/2024] [Indexed: 02/25/2024] Open
Abstract
We have described a new route for the preparation of partially methylated polygalacturonic acid containing hydrolyzed (acidic) and unhydrolyzed (methyl esterified) carboxylate groups in a ratio of 1:1 (PGA, compound 1), and one of its basic FeIII-salts (compound 2) with a ~1:2 FeIII:GA stoichiometry (GA means galacturonic acid and methylated galacturonic acid units). The partially hydrolyzed pectin was transformed into compound 1 with the use of double ion exchange with a strongly acidic macroreticular sulfonated styrene-divinylbenzene copolymer as a hydrogen ion source. The reaction of compound 1 with FeCl3 resulted in compound 2. Compound 2 has a polymeric nature and contains binuclear FeIII(µ-O)(µ-OH)FeIII core units with two kinds of distorted octahedral iron geometries. The salt-forming acidic and methylated GA units of compound 1 are coordinated to FeIII centers in asymmetric bidentate-chelating and -bridging (via C=O group and glycosidic oxygen) modes, respectively. Two kinds of outer-sphere chloride anions were also detected by XPS in various chemical environments fixed by different sets of hydrogen bonds. We also observed a partial reduction of FeIII into FeII due to the ring-opening of the chain-end GA units of compound 1. This reaction provides a new route to determine the number of chain-ends in compound 2, and with the use of the number of GA units calculated from charge neutrality, the average length of these chains and the average molecular weight were also determined. The average molecular weight of the partially methylated polygalacturonic acid used in the industrial-scale production of commercial anti-anemic iron-polygalacturonate agents was ~50,000 g/mol. Compound 2 was also characterized by IR, Mössbauer, and X-ray photoelectron spectroscopy, and magnetic susceptibility measurements. These results on the structure and average molecular weight of basic iron(III) polygalacturonate provide a tool to design Fe-PGA complexes with tuned iron-releasing properties.
Collapse
Affiliation(s)
- László Kótai
- HUN-REN Institute of Materials and Environmental Chemistry, Research Centre for Natural Sciences, Magyar Tudósok Körútja 2, H-1117 Budapest, Hungary
| | - Károly Lázár
- HUN-REN Centre for Energy Research, EKBI, Konkoly Thege Miklós Út, 29-33, H-1121 Budapest, Hungary;
| | | | - Klára Szentmihályi
- HUN-REN Institute of Materials and Environmental Chemistry, Research Centre for Natural Sciences, Magyar Tudósok Körútja 2, H-1117 Budapest, Hungary
| |
Collapse
|
5
|
Rypar T, Bezdekova J, Pavelicova K, Vodova M, Adam V, Vaculovicova M, Macka M. Low-tech vs. high-tech approaches in μPADs as a result of contrasting needs and capabilities of developed and developing countries focusing on diagnostics and point-of-care testing. Talanta 2024; 266:124911. [PMID: 37536103 DOI: 10.1016/j.talanta.2023.124911] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 06/28/2023] [Accepted: 07/02/2023] [Indexed: 08/05/2023]
Abstract
Paper-based analysis has captivated scientists' attention in the field of analytical chemistry and related areas for the last two decades. Arguably no other area of modern chemical analysis is so broad and diverse in its approaches spanning from simple 'low-tech' low-cost paper-based analytical devices (PADs) requiring no or simple instrumentation, to sophisticated PADs and microfluidic paper-based analytical devices (μPADs) featuring elements of modern material science and nanomaterials affording high selectivity and sensitivity. Correspondingly diverse is the applicability, covering resource-limited scenarios on the one hand and most advanced approaches on the other. Herein we offer a view reflecting this diversity in the approaches and types of devices. The core idea of this article rests in dividing μPADs according to their type into two groups: A) instrumentation-free μPADs for resource-limited scenarios or developing countries and B) instrumentation-based μPADs as futuristic POC devices for e-diagnostics mainly aimed at developed countries. Each of those two groups is presented and discussed with the view of the main requirements in the given area, the most common targets, sample types and suitable detection approaches either implementing high-tech elements or low-tech low-cost approaches. Finally, a socioeconomic perspective is offered in discussing the fabrication and operational costs of μPADs, and, future perspectives are offered.
Collapse
Affiliation(s)
- Tomas Rypar
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Jaroslava Bezdekova
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Kristyna Pavelicova
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Milada Vodova
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Vojtech Adam
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Marketa Vaculovicova
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic
| | - Mirek Macka
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123, 612 00, Brno, Czech Republic; Australian Centre for Research on Separation Science and School o Natural Sciences, University of Tasmania, Private Bag 75, Hobart TAS, 7001, Australia.
| |
Collapse
|
6
|
Moreira NS, Pinheiro KMP, Sousa LR, Garcia GDS, Figueredo F, Coltro WKT. Distance-based detection of paracetamol in microfluidic paper-based analytical devices for forensic application. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 16:33-39. [PMID: 38010169 DOI: 10.1039/d3ay01739g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2023]
Abstract
Whisky adulteration is a prevalent practice driven by the high cost of these beverages. Counterfeiters commonly dilute whisky with less expensive alcoholic beverages, water, food additives, drugs or pharmaceuticals. Paracetamol (PAR), an analgesic drug that mitigates hangovers and headaches, is commonly used to adulterate whisky. Currently, the primary method for quantifying PAR levels is high-performance liquid chromatography, but this technique is both time consuming and usually generates more residues. In this context, the utilization of miniaturized and portable analytical devices becomes imperative for conducting point-of-care/need analyses. These devices offer several advantages, including portability, user-friendliness, low cost, and minimal material wastage. This study proposes the selective distance-based PAR quantification on whisky samples using a paper-based microfluidic analytical device (μPAD). Colorimetric detection on paper-based platforms offers great benefits such as affordability, portability, and the ability to detect PAR without complicated instrumentation. The optimal detection conditions were achieved by introducing 5 μL of a mixture containing 7.5 mmol L-1 of Fe(III) and K3[Fe(CN)6] into the detection zone, along with 12 μL of whisky samples into the sample zone. The method exhibited linear behavior within the concentration range from 15 to 120 mg L-1, with a determination coefficient of 0.998. PAR was quantified in adulterated samples. The results obtained with the paper-based devices were compared with a referenced method, and no significant differences were observed at a confidence level of 95%. The μPAD allowed to determine ca. 1 drop of pharmaceutical medicine PAR of 200 mg mL-1 in 1 L of solution, demonstrating excellent sensitivity. This method offers cost-effective and rapid analysis, reducing the consumption of samples, reagents, and wastes. Consequently, it could be considered a viable and portable alternative for analyzing beverages at criminal scenes, customs, and police operations, thereby enhancing the field of forensics.
Collapse
Affiliation(s)
- Nikaele S Moreira
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
| | - Kemilly M P Pinheiro
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
| | - Lucas R Sousa
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
- Laboratorio de Biosensores y Bioanálisis (LABB), Departamento de Química Biológica e IQUIBICEN - CONICET, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires (UBA), Pabellón 2, Ciudad Universitaria, Ciudad Autónoma de Buenos Aires, Argentina
| | - Gabriel D S Garcia
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
| | - Federico Figueredo
- Laboratorio de Biosensores y Bioanálisis (LABB), Departamento de Química Biológica e IQUIBICEN - CONICET, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires (UBA), Pabellón 2, Ciudad Universitaria, Ciudad Autónoma de Buenos Aires, Argentina
| | - Wendell K T Coltro
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
- Laboratorio de Biosensores y Bioanálisis (LABB), Departamento de Química Biológica e IQUIBICEN - CONICET, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires (UBA), Pabellón 2, Ciudad Universitaria, Ciudad Autónoma de Buenos Aires, Argentina
- Instituto Nacional de Ciência e Tecnologia de Bioanalítica, 13084-971, Campinas, SP, Brazil
| |
Collapse
|
7
|
Xiao J, Jiang J, Zhao Z, Guo J, Wang J. Clarity improvement of the discoloration boundary and detection of Hg 2+ ions by using a polystyrene nanoparticle-modified paper-based microdevice. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:2366-2375. [PMID: 37129571 DOI: 10.1039/d3ay00174a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Distance-based microfluidic paper-based analytical devices (μPADs) can be used to calculate the analyte content by reading the length of the discolored area in the channel. A blurred discoloration boundary is difficult to distinguish, resulting in reading errors. In this study, we constructed a μPAD modified with carboxyl-containing polystyrene nanoparticles (PS-μPAD) to improve the discoloration-boundary clarity. The filling of the pores of the fibers with the deposited polystyrene nanoparticles (PS NPs) caused a decrease in the paper porosity, resulting in a flow delay. Meanwhile, the carboxyl groups carried by PS NPs were able to form hydrogen bonds with hydroxyl-containing compounds FLPI, a Hg2+ probe, and the two factors acted synergistically to fix the FLPI to react in situ, raising the discoloration-boundary clarity. Compared with the unmodified μPAD, the detection of Hg2+ ions using the PS-μPAD still had a good linear relationship. Importantly, the color-depth difference inside and outside the discoloration boundary improved by about four times and showed excellent reproducibility in different populations. The method was simple and easy to expand, thereby providing an idea for more widespread application of distance-based μPADs.
Collapse
Affiliation(s)
- Jingcheng Xiao
- College of Chemical & Pharmacy, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China.
| | - Jingjing Jiang
- College of Chemical & Pharmacy, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China.
| | - Zexu Zhao
- College of Chemical & Pharmacy, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China.
| | - Jiahao Guo
- College of Chemical & Pharmacy, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China.
| | - Jinyi Wang
- College of Chemical & Pharmacy, Northwest A&F University, Yangling, Shaanxi 712100, P. R. China.
| |
Collapse
|
8
|
Khan M, Zhao B, Wu W, Zhao M, Bi Y, Hu Q. Distance-based microfluidic assays for instrument-free visual point-of-care testing. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.117029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
|
9
|
Lerner N, Avraham H, Leffler N, Weinstock IA, Zeiri O. Argentometric chloride determination by inductively coupled plasma-optical emission spectroscopy in a wide range of sample matrices. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:1594-1600. [PMID: 36892476 DOI: 10.1039/d3ay00057e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Chloride determination is of great importance, as chloride plays important roles in human health, pitting corrosion, environmental processes, and agriculture. However, chloride determination by inductively coupled plasma-optical emission spectroscopy (ICP-OES), one of the premier techniques used for elemental analysis, is currently limited to specific instrument types or requires the use of additional equipment. This work presents an argentometric method for the indirect measurement of chloride, applicable to any ICP-OES instrument. The initial Ag+ concentration added to samples is of great importance, as it affects both the method's limit of quantification (LOQ) and the top limit of its working range. The developed method found 50 mg L-1 of Ag+ to be the optimal concentration, providing a working range of 0.2-15 mg L-1 Cl-. The method was robust to changes in filtration time, temperature, and sample acidity. Using the argentometric method, chloride was determined in a variety of samples (spiked-purified water, seawater, wine, and urine). For validation, the results were compared to those obtained using ion chromatography and showed no statistical differences. Argentometric chloride determination by ICP-OES is therefore applicable to many types of samples and can be easily performed on any ICP-OES instrument.
Collapse
Affiliation(s)
- Nadav Lerner
- Department of Analytical Chemistry, Nuclear Research Center Negev, P. O. Box 9001, Beer Sheva, Israel.
- Chemistry Department, Ben Gurion University, Beer Sheva, Israel
| | - Hanan Avraham
- Department of Analytical Chemistry, Nuclear Research Center Negev, P. O. Box 9001, Beer Sheva, Israel.
| | - Nitai Leffler
- Chemistry Department, Ben Gurion University, Beer Sheva, Israel
| | - Ira A Weinstock
- Chemistry Department, Ben Gurion University, Beer Sheva, Israel
| | - Offer Zeiri
- Department of Analytical Chemistry, Nuclear Research Center Negev, P. O. Box 9001, Beer Sheva, Israel.
| |
Collapse
|
10
|
Kitaw SL, Birhan YS, Tsai HC. Plasmonic surface-enhanced Raman scattering nano-substrates for detection of anionic environmental contaminants: Current progress and future perspectives. ENVIRONMENTAL RESEARCH 2023; 221:115247. [PMID: 36640935 DOI: 10.1016/j.envres.2023.115247] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 12/26/2022] [Accepted: 01/06/2023] [Indexed: 06/17/2023]
Abstract
Surface-enhanced Raman scattering spectroscopy (SERS) is a powerful technique of vibrational spectroscopy based on the inelastic scattering of incident photons by molecular species. It has unique properties such as ultra-sensitivity, selectivity, non-destructivity, speed, and fingerprinting properties for analytical and sensing applications. This enables SERS to be widely used in real-world sample analysis and basic plasmonic mechanistic studies. However, the desirable properties of SERS are compromised by the high cost and low reproducibility of the signals. The development of multifunctional, stable and reusable nano-engineered SERS substrates is a viable solution to circumvent these drawbacks. Recently, plasmonic SERS active nano-substrates with various morphologies have attracted the attention of researchers due to promising properties such as the formation of dense hot spots, additional stability, tunable and controlled morphology, and surface functionalization. This comprehensive review focused on the current advances in the field of SERS active nanosubstrates suitable for the detection and quantification of anionic environmental pollutants. The common fabrication methods, including the techniques for morphological adjustments and surface modification, substrate categories, and the design of nanotechnologically fabricated plasmonic SERS substrates for anion detection are systematically presented. Here, the need for the design, synthesis, and functionalization of SERS nano-substrates for anions of great environmental importance is explained in detail. In addition, the broad categories of SERS nano-substrates, namely colloid-based SERS substrates and solid-support SERS substrates are discussed. Moreover, a brief discussion of SERS detection of certain anionic pollutants in the environment is presented. Finally, the prospects in the fabrication and commercialization of pilot-scale handheld SERS sensors and the construction of smart nanosubstrates integrated with novel amplifying materials for the detection of anions of environmental and health concern are proposed.
Collapse
Affiliation(s)
- Sintayehu Leshe Kitaw
- Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, 106, Taiwan, ROC
| | - Yihenew Simegniew Birhan
- Department of Chemistry, College of Natural and Computational Sciences, Debre Markos University, P.O. Box 269, Debre Markos, Ethiopia
| | - Hsieh-Chih Tsai
- Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei, 106, Taiwan, ROC; Advanced Membrane Materials Center, National Taiwan University of Science and Technology, Taipei, 106, Taiwan, ROC; R&D Center for Membrane Technology, Chung Yuan Christian University, Chungli, Taoyuan, 320, Taiwan, ROC.
| |
Collapse
|
11
|
Ghasemi F, Fahimi-Kashani N, Bigdeli A, Alshatteri AH, Abbasi-Moayed S, Al-Jaf SH, Merry MY, Omer KM, Hormozi-Nezhad MR. Paper-based optical nanosensors – A review. Anal Chim Acta 2022; 1238:340640. [DOI: 10.1016/j.aca.2022.340640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 11/15/2022] [Accepted: 11/16/2022] [Indexed: 11/23/2022]
|
12
|
Phoonsawat K, Agir I, Dungchai W, Ozer T, Henry CS. A smartphone-assisted hybrid sensor for simultaneous potentiometric and distance-based detection of electrolytes. Anal Chim Acta 2022; 1226:340245. [DOI: 10.1016/j.aca.2022.340245] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 08/04/2022] [Accepted: 08/05/2022] [Indexed: 12/19/2022]
|
13
|
Khachornsakkul K, Phuengkasem D, Palkuntod K, Sangkharoek W, Jamjumrus O, Dungchai W. A Simple Counting-Based Measurement for Paper Analytical Devices and Their Application. ACS Sens 2022; 7:2093-2101. [PMID: 35736786 DOI: 10.1021/acssensors.2c01003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
This work introduces the concept of a counting-based measurement on paper analytical devices (cPADs) to improve the utilization of numerous reactions. The design of cPADs consists of two layers of paper substrates; the first layer contains a central sample zone combined with a radial surrounded by 12 detection zones that are predeposited with the various reagents, and the second layer acts as a connection channel between the sample zone and each detection zone. The solution can vertically flow from the first to the second layer and then move through the area to each subsequent detection zone. The analyte level can be evaluated by counting the number of detection zones that change color from a blank signal. Furthermore, our cPADs exhibit a capability of implementation for a broad series of reactions. Compared to the dPAD technique, some reactions that are possibly difficult to apply in such devices can be wholly enabled in our devices. The final color reaction on cPADs can apparently occur due to its identity. We applied this technique to the monitoring of carbaryl (CBR) and copper ions (Cu2+) using different reactions, including azo-coupling and complexation, respectively. Accordingly, this indicates an excellent result validated using the more traditional methods. Our cPADs can be applied for rapid screening of both CBR and Cu2+ in water samples with outstanding accuracy and precision using a naked-eye measurement by a relatively unskilled person. We offer a simple platform on PADs for rapid screening, combining high cost-effectiveness within a miniaturized platform designed for use with onsite applications, which is thus suitable for several different reactions.
Collapse
Affiliation(s)
- Kawin Khachornsakkul
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| | - Danai Phuengkasem
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| | - Kitiya Palkuntod
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| | - Wuttichai Sangkharoek
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| | - Opor Jamjumrus
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| | - Wijitar Dungchai
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| |
Collapse
|
14
|
Xu C, Zhou G, Cai H, Chen Y, Huang L, Cai L, Gong J, Yan Z. Modification of Microfluidic Paper-Based Devices with an Oxidant Layer for Distance Readout of Reducing Substances. ACS OMEGA 2022; 7:20383-20389. [PMID: 35721922 PMCID: PMC9202063 DOI: 10.1021/acsomega.2c02537] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2022] [Accepted: 05/19/2022] [Indexed: 05/20/2023]
Abstract
We developed a novel strategy for modification of paper cellulose with water-insoluble oxidants for distance readout of reducing substances on microfluidic paper-based analytical devices (μPADs). Water-insoluble oxidants were formed and modified onto paper cellulose through the redox reaction that occurred between paper cellulose and potassium permanganate deposited on the paper channel, developing a yellowish-brown color on the channel. As aqueous solutions containing reducing substances flowed along the channel, reducing substances were consumed owing to the redox reaction that occurred between oxidants and reducing substances until the reducing substances were depleted, forming a discolored zone on the yellowish-brown channel. The redox reaction between insoluble oxidants and reducing substances on the paper cellulose could be used for distance-based detection of a wide variety of reducing substances, which is similar to the classical potassium permanganate titration that employs the redox reaction that occurred between potassium permanganate and reducing substances. We believe that this method will broaden the analytical applications of distance-based detection on μPADs. This method was applied to ascorbic acid assay and captopril assay in real samples with analytical results comparing well with the labeled values, demonstrating its great potential in real sample analysis.
Collapse
Affiliation(s)
- Chunxiu Xu
- School
of Chemistry and Environmental Engineering, Hanshan Normal University, Chaozhou, Guangdong 521041, China
| | - Guoxing Zhou
- School
of Chemistry and Environmental Engineering, Hanshan Normal University, Chaozhou, Guangdong 521041, China
| | - Huihui Cai
- School
of Chemistry and Environmental Engineering, Hanshan Normal University, Chaozhou, Guangdong 521041, China
| | - Yicong Chen
- School
of Chemistry and Environmental Engineering, Hanshan Normal University, Chaozhou, Guangdong 521041, China
| | - Ling Huang
- School
of Chemistry and Environmental Engineering, Hanshan Normal University, Chaozhou, Guangdong 521041, China
| | - Longfei Cai
- School
of Chemistry and Environmental Engineering, Hanshan Normal University, Chaozhou, Guangdong 521041, China
| | - Jiaye Gong
- School
of Chemistry and Environmental Engineering, Hanshan Normal University, Chaozhou, Guangdong 521041, China
| | - Zankai Yan
- School
of Chemistry and Environmental Engineering, Hanshan Normal University, Chaozhou, Guangdong 521041, China
| |
Collapse
|
15
|
Shi X, Kralj M, Zhang Y. Colorimetric paper test strips based on cesium lead bromide perovskite nanocrystals for rapid detection of ciprofloxacin hydrochloride. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2022; 34:304002. [PMID: 35533658 DOI: 10.1088/1361-648x/ac6e1d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Accepted: 05/09/2022] [Indexed: 06/14/2023]
Abstract
The detection of drugs containing hydrochloric salt with conventional methods is time consuming and expensive. In this work, upon exposure to ciprofloxacin hydrochloride at different concentrations, the emission from CsPbBr3NCs shifts to the blue from 513 nm to 442 nm. CsPbBr(3-x)ClxNCs are formed by the ion exchange and substitution of Br-and Cl-ions from surface to core of NCs. The first-principles calculations suggest that the substitution of Br-by Cl-ions plays a critical role in the tuning of the energy bandgap. The color of paper test strips changes immediately after exposure to different Ciproxan solutions. We propose that this rapid and portable method has a high potential application in other chloride salts for food safety.
Collapse
Affiliation(s)
- Xiaoqing Shi
- International Joint Laboratory of New Energy Materials and Devices of Henan Province, School of Physics and Electronics, Henan University, Kaifeng, 475004, People's Republic of China
| | - Marko Kralj
- Center of Excellence for Advanced Materials and Sensing Devices, Institute of Physics, Zagreb 10000, Croatia
| | - Yang Zhang
- International Joint Laboratory of New Energy Materials and Devices of Henan Province, School of Physics and Electronics, Henan University, Kaifeng, 475004, People's Republic of China
| |
Collapse
|
16
|
Nuchtavorn N, Rypar T, Nedjl L, Vaculovicova M, Macka M. Distance-based detection in analytical flow devices: from gas detection tubes to microfluidic chips and microfluidic paper-based analytical devices. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116581] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
17
|
Phoonsawat K, Ozer T, Dungchai W, Henry CS. Dual-mode ion-selective electrodes and distance-based microfluidic device for detection of multiple urinary electrolytes. Analyst 2022; 147:4517-4524. [DOI: 10.1039/d2an01220k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Here, we developed a microfluidic paper device by combining ion-selective electrodes (ISE) and a distance-based paper device (dPAD) for simultaneous potentiometric and colorimetric detection of urine electrolytes including K+, Na+ and Cl−.
Collapse
Affiliation(s)
- Kamonchanok Phoonsawat
- Organic Synthesis, Electrochemistry & Natural Product Research Unit, Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Bangkok, 10140, Thailand
- Engineering Science Classroom, Darunsikkhalai School, King Mongkut's University of Technology Thonburi, Bangkok, 10140, Thailand
- Department of Chemistry, Colorado State University, Fort Collins, CO 80523, USA
| | - Tugba Ozer
- Department of Bioengineering, Faculty of Chemical-Metallurgical Engineering, Yildiz Technical University, 34220 Istanbul, Turkey
| | - Wijitar Dungchai
- Organic Synthesis, Electrochemistry & Natural Product Research Unit, Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Bangkok, 10140, Thailand
| | - Charles S. Henry
- Department of Chemistry, Colorado State University, Fort Collins, CO 80523, USA
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, USA
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
18
|
Sharma R, Geranpayehvaghei M, Ejeian F, Razmjou A, Asadnia M. Recent advances in polymeric nanostructured ion selective membranes for biomedical applications. Talanta 2021; 235:122815. [PMID: 34517671 DOI: 10.1016/j.talanta.2021.122815] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 08/13/2021] [Accepted: 08/18/2021] [Indexed: 12/30/2022]
Abstract
Nano structured ion-selective membranes (ISMs) are very attractive materials for a wide range of sensing and ion separation applications. The present review focuses on the design principles of various ISMs; nanostructured and ionophore/ion acceptor doped ISMs, and their use in biomedical engineering. Applications of ISMs in the biomedical field have been well-known for more than half a century in potentiometric analysis of biological fluids and pharmaceutical products. However, the emergence of nanotechnology and sophisticated sensing methods assisted in miniaturising ion-selective electrodes to needle-like sensors that can be designed in the form of implantable or wearable devices (smartwatch, tattoo, sweatband, fabric patch) for health monitoring. This article provides a critical review of recent advances in miniaturization, sensing and construction of new devices over last decade (2011-2021). The designing of tunable ISM with biomimetic artificial ion channels offered intensive opportunities and innovative clinical analysis applications, including precise biosensing, controlled drug delivery and early disease diagnosis. This paper will also address the future perspective on potential applications and challenges in the widespread use of ISM for clinical use. Finally, this review details some recommendations and future directions to improve the accuracy and robustness of ISMs for biomedical applications.
Collapse
Affiliation(s)
- Rajni Sharma
- School of Engineering, Macquarie University, Sydney, NSW, 2109, Australia
| | - Marzieh Geranpayehvaghei
- School of Engineering, Macquarie University, Sydney, NSW, 2109, Australia; Department of Nanobiotechnology, Faculty of Biological Sciences, Tarbiat Modares University, Tehran, 14115-175, Iran
| | - Fatemeh Ejeian
- Department of Animal Biotechnology, Cell Science Research Center, Royan Institute for Biotechnology, ACECR, Isfahan, Iran; Department of Biotechnology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, 73441-81746, Iran
| | - Amir Razmjou
- School of Engineering, Macquarie University, Sydney, NSW, 2109, Australia; Department of Biotechnology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, 73441-81746, Iran; Centre for Technology in Water and Wastewater, University of Technology Sydney, New South Wales, Australia; UNESCO Center for Membrane Technology, School of Chemical Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| | - Mohsen Asadnia
- School of Engineering, Macquarie University, Sydney, NSW, 2109, Australia.
| |
Collapse
|
19
|
Rahbar M, Zou S, Baharfar M, Liu G. A Customized Microfluidic Paper-Based Platform for Colorimetric Immunosensing: Demonstrated via hCG Assay for Pregnancy Test. BIOSENSORS 2021; 11:bios11120474. [PMID: 34940231 PMCID: PMC8699738 DOI: 10.3390/bios11120474] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 11/20/2021] [Accepted: 11/22/2021] [Indexed: 05/14/2023]
Abstract
Over the past decades, paper-based lateral flow immunoassays (LFIAs) have been extensively developed for rapid, facile, and low-cost detection of a wide array of target analytes in a point-of-care manner. Conventional home pregnancy tests are the most significant example of LFAs, which detect elevated concentrations of human chorionic gonadotrophin (hCG) in body fluids to identify early pregnancy. In this work, we have upgraded these platforms to a higher version by developing a customized microfluidic paper-based analytical device (μPAD), as the new generation of paper-based point-of-care platforms, for colorimetric immunosensing. This will offer a cost-efficient and environmentally friendly alternative platform for paper-based immunosensing, eliminating the need for nitrocellulose (NC) membrane as the substrate material. The performance of the developed platform is demonstrated by detection of hCG (as a model case) in urine samples and subsequently indicating positive or negative pregnancy. A dual-functional silane-based composite was used to treat filter paper in order to enhance the colorimetric signal intensity in the detection zones of μPADs. In addition, microfluidic pathways were designed in a manner to provide the desired regulated fluid flow, generating sufficient incubation time (delays) at the designated detection zones, and consequently enhancing the obtained signal intensity. The presented approaches allow to overcome the existing limitations of μPADs in immunosensing and will broaden their applicability to a wider range of assays. Although, the application of the developed hCG μPAD assay is mainly in qualitative (i.e., positive or negative) detection of pregnancy, the semi-quantitative measurement of hCG was also investigated, indicating the viability of this assay for sensitive detection of the target hCG analyte within the related physiological range (i.e., 10-500 ng/mL) with a LOD value down to 10 ng/mL.
Collapse
Affiliation(s)
- Mohammad Rahbar
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney, NSW 2052, Australia; (M.R.); (M.B.)
| | - Siyi Zou
- School of Life and Health Sciences, The Chinese University of Hong Kong, Shenzhen 518172, China;
| | - Mahroo Baharfar
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney, NSW 2052, Australia; (M.R.); (M.B.)
| | - Guozhen Liu
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney, NSW 2052, Australia; (M.R.); (M.B.)
- School of Life and Health Sciences, The Chinese University of Hong Kong, Shenzhen 518172, China;
- Correspondence:
| |
Collapse
|
20
|
Abstract
The chloride ion (Cl−) is a type of anion which is commonly found in the environment and has important physiological functions and industrial uses. However, a high content of Cl− in water will do harm to the ecological environment, human health and industrial production. It is of great significance to strictly monitor the Cl− content in water. Following the recent development of society and industry, large amounts of domestic sewage and industrial sewage are discharged into the environment, which results in the water becoming seriously polluted by Cl−. The detection of Cl− has gradually become a research focus. This paper introduces the harm of Cl− pollution in the environment and summarizes various Cl− detection methods, including the volumetric method, spectrophotometry method, electrochemical method, ion chromatography, paper-based microfluidic technology, fluorescent molecular probe, and flow injection. The principle and application of each technology are described; their advantages, disadvantages, and applicability are discussed. To goal of this research is to find a more simple, rapid, environmental protection and strong anti-interference detection technology of Cl−.
Collapse
|
21
|
Tai WC, Chang YC, Chou D, Fu LM. Lab-on-Paper Devices for Diagnosis of Human Diseases Using Urine Samples-A Review. BIOSENSORS 2021; 11:260. [PMID: 34436062 PMCID: PMC8393526 DOI: 10.3390/bios11080260] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 07/26/2021] [Accepted: 07/29/2021] [Indexed: 12/23/2022]
Abstract
In recent years, microfluidic lab-on-paper devices have emerged as a rapid and low-cost alternative to traditional laboratory tests. Additionally, they were widely considered as a promising solution for point-of-care testing (POCT) at home or regions that lack medical infrastructure and resources. This review describes important advances in microfluidic lab-on-paper diagnostics for human health monitoring and disease diagnosis over the past five years. The review commenced by explaining the choice of paper, fabrication methods, and detection techniques to realize microfluidic lab-on-paper devices. Then, the sample pretreatment procedure used to improve the detection performance of lab-on-paper devices was introduced. Furthermore, an in-depth review of lab-on-paper devices for disease measurement based on an analysis of urine samples was presented. The review concludes with the potential challenges that the future development of commercial microfluidic lab-on-paper platforms for human disease detection would face.
Collapse
Affiliation(s)
- Wei-Chun Tai
- Department of Oral and Maxillofacial Surgery, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 833, Taiwan;
| | - Yu-Chi Chang
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan;
| | - Dean Chou
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan;
| | - Lung-Ming Fu
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan;
- Graduate Institute of Materials Engineering, National Pingtung University of Science and Technology, Pingtung 912, Taiwan
| |
Collapse
|
22
|
Zhang H, Li X, Qian ZM, Wang S, Yang FQ. Glucose oxidase-mediated sodium alginate gelation: Equipment-Free detection of glucose in fruit samples. Enzyme Microb Technol 2021; 148:109805. [PMID: 34116756 DOI: 10.1016/j.enzmictec.2021.109805] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Revised: 04/13/2021] [Accepted: 04/16/2021] [Indexed: 10/21/2022]
Abstract
In this study, a paper-based sensor, combined with a visual distance-readout method, was developed to determine glucose in fruit samples based on the glucose oxidase-mediated sodium alginate gelation. The type of filter paper, the concentration of sodium alginate and the enzymatic reaction conditions were systematically investigated. Under optimal conditions, the increase in diffusion diameter showed a good linear relationship with glucose concentration between 1.4-7.0 mM, and the limit of quantification was 1.4 mM. Finally, the applicability of the proposed strategy was successfully verified by measuring glucose concentrations in fruit samples. The results generated by the developed paper-based sensor were in good agreement with the results obtained from a glucose assay kit. The recoveries were 91.8%-99.1%. In short, the present study developed a simple, low-cost and efficient method for assessing fruit quality and for guiding fruit intake for diabetic patients, especially in remote or resource-limited regions.
Collapse
Affiliation(s)
- Hao Zhang
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing, 401331, China
| | - Xiuzhu Li
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macao, China
| | | | - Shengpeng Wang
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macao, China
| | - Feng-Qing Yang
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing, 401331, China.
| |
Collapse
|
23
|
Khachornsakkul K, Chang JJ, Lin PH, Lin YH, Dungchai W, Chen CH. Highly sensitive distance-based liquid crystalline visualization for paper-based analytical devices. Anal Chim Acta 2021; 1154:338328. [PMID: 33736795 DOI: 10.1016/j.aca.2021.338328] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 01/20/2021] [Accepted: 02/14/2021] [Indexed: 11/25/2022]
Abstract
We successfully report on the first demonstration of a highly sensitive distance-based liquid crystalline visualization for paper-based analytical devices. The construction of this paper sensor was achieved by immobilizing 4-cyano-4'-pentylbiphenyl (5CB) as liquid crystalline molecules (LCs) onto a paper strip substrate. The sensing mechanism is based on the ultrasound-assisted decomposition of 5CB by the hydroxyl radical (•OH) which is generated from the oxidase enzymatic reaction of the analyte, this then results in the change of texture and color of paper. The utility of our devices was then demonstrated with the determination of bilirubin (BR) in biological samples using a bilirubin oxidase enzymatic reaction. The quantification of BR can be achieved by dipping the tip of the paper strips into the analyte solutions and then by measuring the length of color which has been changed on the paper, by the naked eye. Under optimized conditions, this paper sensor offered the linear range of BR detection from 2.0 to 30.0 pmol/L (R2 = 0.9945) with the limit of detection (LOD) of 0.80 pmol/L. In addition, the results of this sensor were highly reproducible, with a relative standard deviation (RSD) of less than 3.50%. The recoveries of spiked BR in human urine and serum samples were in the range of 99.09-107.89%, which demonstrates the high accuracy of this paper sensor. Overall, this work presents a simple method to determine the concentration of H2O2 and BR at pmol levels with an instrument-free length-measuring readout, so it could be suitable for quantitative analysis of other biomarkers based on oxidase enzymatic reaction, which can provide important information about early disease diagnosis and patient prognosis.
Collapse
Affiliation(s)
- Kawin Khachornsakkul
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok, 10140, Thailand
| | - Jung-Jung Chang
- Department of Chemistry, Tamkang University, New Taipei City, 25137, Taiwan
| | - Ping-Heng Lin
- Department of Chemistry, Tamkang University, New Taipei City, 25137, Taiwan
| | - Yi-Han Lin
- Department of Chemistry, Tamkang University, New Taipei City, 25137, Taiwan
| | - Wijitar Dungchai
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok, 10140, Thailand.
| | - Chih-Hsin Chen
- Department of Chemistry, Tamkang University, New Taipei City, 25137, Taiwan.
| |
Collapse
|
24
|
Colorimetric Determination of Chloridion in Domestic Water Based on the Wavelength Shift of CsPbBr3 Perovskite Nanocrystals via Halide Exchange. JOURNAL OF ANALYSIS AND TESTING 2021. [DOI: 10.1007/s41664-021-00160-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
AbstractCubic phase CsPbBr3 perovskite nanocrystals (PNCs) was prepared by a high-temperature hot-injection method. The high photoluminescence quantum yield (PLQY) of as-prepared CsPbBr3 PNCs was 87%, which can be used for the determination of chloridion in domestic water samples based on their wavelength-shift characteristics via halide exchange. The proposal approach for the determination of chloridion reveals a linear correlation ranged from 10 to 200 μM of the chloridion concentration and the wavelength shift of CsPbBr3 PNCs with a correlation coefficient of R2 = 0.9956. The as-mentioned method reveals neglectable responses towards those co-existing ions in the water aside from chloridion, due to the quick exchange between Cl and Br and the outstanding color change caused by wavelength shift. The strategy has been applied to the determination of chloridion in water samples with the recoveries of 98.9–104.2% and the limit of detection (LOD) of 4 μM. These results show that the suggested approach is promising for the development of novel fluorescence detection for chloridion in water.
Collapse
|
25
|
Gul I, Le W, Jie Z, Ruiqin F, Bilal M, Tang L. Recent advances on engineered enzyme-conjugated biosensing modalities and devices for halogenated compounds. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2020.116145] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
26
|
Wu H, Shi C, Zhu Q, Li Y, Xu Z, Wei C, Chen D, Huang X. Capillary-driven blood separation and in-situ electrochemical detection based on 3D conductive gradient hollow fiber membrane. Biosens Bioelectron 2021; 171:112722. [DOI: 10.1016/j.bios.2020.112722] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 09/10/2020] [Accepted: 10/10/2020] [Indexed: 11/17/2022]
|
27
|
Teprek A, Poetri Artono V, Waiyawat W, Limsakul A, Shiowatana J, Siripinyanond A. Semi-quantitative analysis by spot counting on origami paper-based device for endpoint detection in titrimetric analysis. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
28
|
Baharfar M, Rahbar M, Tajik M, Liu G. Engineering strategies for enhancing the performance of electrochemical paper-based analytical devices. Biosens Bioelectron 2020; 167:112506. [PMID: 32823207 DOI: 10.1016/j.bios.2020.112506] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 08/07/2020] [Accepted: 08/07/2020] [Indexed: 12/15/2022]
Abstract
Applications of electrochemical detection methods in microfluidic paper-based analytical devices (μPADs) has revolutionized the area of point-of-care (POC) testing towards highly sensitive and selective quantification of various (bio)chemical analytes in a miniaturized, low-coat, rapid, and user-friendly manner. Shortly after the initiation, these relatively new modulations of μPADs, named as electrochemical paper-based analytical devices (ePADs), gained widespread popularity within the POC research community thanks to the inherent advantages of both electrochemical sensing and usage of paper as a suitable substrate for POC testing platforms. Even though general aspects of ePADs such as applications and fabrication techniques, have already been reviewed multiple times in the literature, herein, we intend to provide a critical engineering insight into the area of ePADs by focusing particularly on the practical strategies utilized to enhance their analytical performance (i.e. sensitivity), while maintaining the desired simplicity and efficiency intact. Basically, the discussed strategies are driven by considering the parameters potentially affecting the generated electrochemical signal in the ePADs. Some of these parameters include the type of filter paper, electrode fabrication methods, electrode materials, fluid flow patterns, etc. Besides, the limitations and challenges associated with the development of ePADs are discussed, and further insights and directions for future research in this field are proposed.
Collapse
Affiliation(s)
- Mahroo Baharfar
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney NSW, 2052, Australia
| | - Mohammad Rahbar
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney NSW, 2052, Australia
| | - Mohammad Tajik
- School of Chemistry, The University of New South Wales, Sydney NSW, 2052, Australia
| | - Guozhen Liu
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney NSW, 2052, Australia.
| |
Collapse
|
29
|
Gorbunova MO, Apyari VV, Baulina AA, Garshina MS, Kulyaginova MS, Shevchenko AV, Furletov AA, Dmitrienko SG, Zolotov YA. An improved step-by-step airflow/paper-based colorimetric method for highly selective determination of halides in complex matrices. Talanta 2020; 219:121254. [PMID: 32887145 DOI: 10.1016/j.talanta.2020.121254] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 06/01/2020] [Accepted: 06/03/2020] [Indexed: 11/30/2022]
Abstract
An improved step-by-step colorimetric method for determination of halides has been developed. The method is based on successive selective oxidation of iodide, bromide and chloride into corresponding free halogens, their extraction by airflow and colorimetric detection with different paper test-strips. This procedure can be performed in a single analyzed solution and possesses high selectivity and good sensitivity due to the extraction step. Three types of paper test-strips were examined: paper modified with tetramethylammonium iodide and starch, paper modified with methyl orange and paper modified with silver triangular nanoplates. Limits of detection for iodide, bromide and chloride are 0.01, 0.02, and 0.04 mg L-1 respectively in case of the last mentioned paper. The method was applied to the analysis of samples having complex matrices, such as various seafood, preserves, bread, and natural waters, showing good accuracy of the analysis with recoveries of 95-105% and relative standard deviations not higher than 6%.
Collapse
Affiliation(s)
- Marina O Gorbunova
- Southern Federal University, Department of Chemistry, Zorge St., 7, 344090, Rostov-on-Don, Russia; Rostov State Medical University of the Ministry of Healthcare of Russian Federation, Pharmaceutical Faculty, Nakhichevansky Lane, 29, 344022, Rostov-on-Don, Russia
| | - Vladimir V Apyari
- Department of Chemistry, Lomonosov Moscow State University, Leninskie Gory, 1/3, 119991, Moscow, Russia.
| | - Anastasiya A Baulina
- Southern Federal University, Department of Chemistry, Zorge St., 7, 344090, Rostov-on-Don, Russia
| | - Maria S Garshina
- Southern Federal University, Department of Chemistry, Zorge St., 7, 344090, Rostov-on-Don, Russia
| | - Margarita S Kulyaginova
- Rostov State Medical University of the Ministry of Healthcare of Russian Federation, Pharmaceutical Faculty, Nakhichevansky Lane, 29, 344022, Rostov-on-Don, Russia
| | - Anastasiya V Shevchenko
- Southern Federal University, Department of Chemistry, Zorge St., 7, 344090, Rostov-on-Don, Russia
| | - Aleksei A Furletov
- Department of Chemistry, Lomonosov Moscow State University, Leninskie Gory, 1/3, 119991, Moscow, Russia
| | - Stanislava G Dmitrienko
- Department of Chemistry, Lomonosov Moscow State University, Leninskie Gory, 1/3, 119991, Moscow, Russia
| | - Yury A Zolotov
- Department of Chemistry, Lomonosov Moscow State University, Leninskie Gory, 1/3, 119991, Moscow, Russia; Kurnakov Institute of General and Inorganic Chemistry of the Russian Academy of Sciences, Leninsky Prospect, 31, 119991, Moscow, Russia
| |
Collapse
|
30
|
Granica M, Tymecki Ł. Prussian Blue (bio)sensing device for distance-based measurements. Anal Chim Acta 2020; 1136:125-133. [PMID: 33081936 DOI: 10.1016/j.aca.2020.08.037] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2020] [Revised: 07/23/2020] [Accepted: 08/20/2020] [Indexed: 01/12/2023]
Abstract
In this research, microfluidic paper distance-based systems for the quantification of redox species are proposed. For the preparation of the sensing zone a Prussian Blue (PB) (convertible to Prussian White (PW)) layer was deposited in the channel manufactured by wax-printing technique. According to the chemical properties of PB/PW system, it is possible to develop optical sensors sensitive to both oxidizing and reducing agents. The created systems were evaluated for the determination of ascorbic acid and hydrogen peroxide, which were chosen and used as model analytes. The final versions of the proposed systems exhibited a linear response from 0.25 mmol L-1 to 4.0 and 2.0 mmol L-1 for ascorbic acid and H2O2, respectively. The analytical utility of the paper systems was confirmed by measuring the levels of ascorbic acid in dietary supplements. Results correlation obtained for the described systems and the reference method was over 0.98 (Pearson's R-coefficient). All measurements were characterized by satisfactory reproducibility and acceptable uncertainty (RSD (%) < 6%). Finally, it was demonstrated that the modification of the PW-strip systems with oxidoreductase led to an enzymatic assay for glucose up to 10 mmol L-1 range. Practical utility of the developed bio-strips was confirmed by quantifying glucose in drinks and dietary supplement samples.
Collapse
Affiliation(s)
- Mateusz Granica
- University of Warsaw, Faculty of Chemistry, Pasteur 1, 02-093, Warsaw, Poland.
| | - Łukasz Tymecki
- University of Warsaw, Faculty of Chemistry, Pasteur 1, 02-093, Warsaw, Poland
| |
Collapse
|
31
|
Cai L, Ouyang Z, Song J, Yang L. Indicator-Free Argentometric Titration for Distance-Based Detection of Chloride Using Microfluidic Paper-Based Analytical Devices. ACS OMEGA 2020; 5:18935-18940. [PMID: 32775894 PMCID: PMC7408202 DOI: 10.1021/acsomega.0c02143] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Accepted: 07/08/2020] [Indexed: 06/11/2023]
Abstract
We described an indicator-free argentometric titration strategy using a microfluidic paper-based analytical device. This strategy was based on the formation of insoluble silver salts by reactions occurring between analytes and titrant (Ag+) on a paper channel. After the insoluble silver salts were formed and precipitated on the channel, the paper substrate modified with the surplus titrant on the channel turned reddish-brown by exposure of the devices to a simple and cheap UV light source for 5 min, generating a colored band on the channel. Distance-based detection of chloride was achieved by measuring the length of the colored band with a detection limit of 1.7 mg L-1 Cl-. This method was used to detect chlorides in tap water, with an analytical result (10.1 ± 1.2 mg L-1) agreeing well with that obtained by a classical conventional precipitation titration (9.8 mg L-1), which was based on the measurement of the consumed volume of titrant. This paper-based precipitation titration method is free of skilled personnel and has advantages of low reagent/sample consumption, disposability, portability, and simple operation over the conventional precipitation titration. More importantly, being free of any indicator, this method may be used to detect more species than the conventional precipitation titrations, which are limited by the indicator, for example, CO3 2- and SO4 2-, which could form insoluble silver salts in aqueous liquids. Additionally, comparing with most of those paper-based titrimetry reported previously, this presented precipitation titration is free of any indicator or ion selective electrode to detect the end point of titration.
Collapse
Affiliation(s)
- Longfei Cai
- School
of Chemistry and Environmental Engineering, Hanshan Normal University, Chaozhou, Guangdong 521041, China
| | - Zhuang Ouyang
- School
of Chemistry and Environmental Engineering, Hanshan Normal University, Chaozhou, Guangdong 521041, China
| | - Jiahong Song
- School
of Chemistry and Environmental Engineering, Hanshan Normal University, Chaozhou, Guangdong 521041, China
| | - Liye Yang
- Chaozhou
Central Hospital, Chaozhou, Guangdong 521000, China
| |
Collapse
|
32
|
|
33
|
Wu H, Ma Z, Wei C, Jiang M, Hong X, Li Y, Chen D, Huang X. Three-Dimensional Microporous Hollow Fiber Membrane Microfluidic Device Integrated with Selective Separation and Capillary Self-Driven for Point-of-Care Testing. Anal Chem 2020; 92:6358-6365. [DOI: 10.1021/acs.analchem.9b05342] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- Huimin Wu
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027, China
| | - Zhen Ma
- School of Medicine, Hangzhou Normal University, Hangzhou 311121, China
| | - Chenjie Wei
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027, China
| | - Min Jiang
- School of Medicine, Hangzhou Normal University, Hangzhou 311121, China
| | - Xiao Hong
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027, China
| | - Yang Li
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027, China
| | - Dajing Chen
- School of Medicine, Hangzhou Normal University, Hangzhou 311121, China
| | - Xiaojun Huang
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027, China
| |
Collapse
|
34
|
Distance-based paper device using polydiacetylene liposome as a chromogenic substance for rapid and in-field analysis of quaternary ammonium compounds. Anal Bioanal Chem 2020; 412:3221-3230. [PMID: 32242258 DOI: 10.1007/s00216-020-02583-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 02/29/2020] [Accepted: 03/05/2020] [Indexed: 10/24/2022]
Abstract
This work presents an affordable distance-based microfluidic paper-based device (μPAD), using polydiacetylene (PDA) liposome as a chromogenic substance with a smartphone-based photo editor, for rapid and in-field analysis of quaternary ammonium compounds (QACs) (e.g., didecyldimethylammonium chloride (DDAC), benzyldimethyltetradecyl ammonium chloride (BAC), and cetylpyridinium chloride (CPC)). In-field analysis of these compounds is important to ensure their antimicrobial activity and user safety since they are widely utilized as disinfectants in households and hospitals. The μPAD featured a thermometer-like shape consisting of a sample reservoir and a microchannel as the detection zone, which was pre-deposited with PDA liposome. The color change from blue to red appeared in the presence of QACs and the color bar lengths were proportional to the QAC concentrations. Reactions of QACs with the PDA required a specific pH range (from pH 4.0 to 10.0) and a readout time of 7 min. Analytical performance characteristics of the device were tested with DDAC, BAC, and CPC showing acceptable specificity, accuracy (96.1-109.4%), and precision (%RSDs ≤ 9.3%). Limits of detection and quantitation were in the ranges of 20 to 80 and 70 to 250 μM, respectively. Feasibility of the newly developed device was demonstrated for in-field analysis of QACs in fumigation solution providing comparable results with those obtained from a colorimetric assay (P > 0.05). The proposed device shows potentials for further applications of other analytes since it offers speed, simplicity, and affordability for in-field analysis, especially in remote areas where expertise, resources, and infrastructures are limited. Graphical abstract.
Collapse
|
35
|
Nuchtavorn N, Leanpolchareanchai J, Suntornsuk L, Macka M. Paper-based sol-gel thin films immobilized cytochrome P450 for enzyme activity measurement. Anal Chim Acta 2020; 1098:86-93. [DOI: 10.1016/j.aca.2019.11.031] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2019] [Revised: 10/28/2019] [Accepted: 11/05/2019] [Indexed: 12/18/2022]
|
36
|
Rahbar M, Wheeler AR, Paull B, Macka M. Ion-Exchange Based Immobilization of Chromogenic Reagents on Microfluidic Paper Analytical Devices. Anal Chem 2019; 91:8756-8761. [DOI: 10.1021/acs.analchem.9b01288] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Mohammad Rahbar
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart 7001, Australia
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario M5S 3H6, Canada
- Donnelly Centre for Cellular and Biomolecular Research, 160 College Street, Toronto, Ontario M5S 3E1, Canada
| | - Aaron R. Wheeler
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario M5S 3H6, Canada
- Donnelly Centre for Cellular and Biomolecular Research, 160 College Street, Toronto, Ontario M5S 3E1, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, 164 College Street, Toronto, Ontario M5S 3G9, Canada
| | - Brett Paull
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart 7001, Australia
| | - Mirek Macka
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart 7001, Australia
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno, Czech Republic
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00 Brno, Czech Republic
| |
Collapse
|