1
|
Zhao T, Jin B. A label-free electrochemical biosensor based on a bimetallic organic framework for the detection of carbohydrate antigen 19-9. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:6173-6182. [PMID: 39189647 DOI: 10.1039/d4ay01432d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/28/2024]
Abstract
Carbohydrate antigen 19-9 (CA19-9) is an important marker for pancreatic cancer, ovarian cancer and other tumors, and its rapid and stable detection is the basis for early diagnosis and treatment. In this paper, a label-free electrochemical immunosensor for the sensitive detection of CA19-9 has been developed. First, the synthesis of two novel core-shell bimetallic nanomaterials, namely Ce-MOF-on-Fe-MOF and Fe-MOF-on-Ce-MOF, was accomplished using the MOF-on-MOF approach. The poor electrical conductivity of MOF materials was addressed by incorporating polyethylenimide (PEI) functionalized rGO with Ce-MOF-on-Fe-MOF and Fe-MOF-on-Ce-MOF nanomaterials. Simultaneously, toluidine blue (Tb) was employed as a redox probe and physically adsorbed onto the synthesized materials, resulting in the formation of two nanomaterials: rGO@Ce-MOF-on-Fe-MOF@Tb and rGO@Fe-MOF-on-Ce-MOF@Tb. The fundamental characterization reveals that the sensing performance of the rGO@Ce-MOF-on-Fe-MOF@TB-based immune sensor surpasses that of the rGO@Fe-MOF-on-Ce-MOF@TB-based immune sensor, which is attributed to the fact that, unlike the interlayer-constrained structure of Fe-MOF-on-Ce-MOF, in Ce-MOF-on-Fe-MOF, Ce-MOF penetrates into Fe-MOF to form a heterogeneous structure due to the relatively large pore size of Fe-MOF, which better combines the excellent biocompatibility and strong anchoring effect of Fe MOFs on antibodies, as well as the high electrochemical activity and conductivity of Ce-MOF, to enhance sensing performance. The proposed label-free immunosensor based on rGO@Ce-MOF-on-Fe-MOF@Tb has a wide linear range (1-100 000 mU mL-1), a low detection limit (0.34 mU mL-1), good stability, reproducibility, and repeatability, and satisfactory applicability, which provides a potential platform for clinical applications.
Collapse
Affiliation(s)
- Tongxiao Zhao
- Department of Chemistry, Anhui University, Hefei 230601, China.
| | - Baokang Jin
- Department of Chemistry, Anhui University, Hefei 230601, China.
| |
Collapse
|
2
|
Zhang T, Ma Y, Zhang Y. A simple electrochemical strategy for the detection of the cancer marker CA19-9 by signal amplification using copper organic framework nanocomposite. Analyst 2023; 148:5905-5914. [PMID: 37855742 DOI: 10.1039/d3an01511d] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2023]
Abstract
In this work, label-free electrochemical immunosensing of the cancer biomarker carbohydrate antigen 19-9 (CA19-9) is reported using [Fe(CN)6]3-/4- as a signal probe and a copper organic framework (Cu-BTC) nanocomposite for the amplification of the signal. The immunosensor was fabricated by the following process. First, the Cu-BTC nanomaterial with a larger surface area and good biocompatibility was synthesized to improve the dispersion of gold nanoparticles (Au NPs). Then, nitrogen-doped graphene (N-GR) was combined with Cu-BTC to form the nanocomposite. The synthesized Cu-BTC@N-GR@AuNPs@CS nanocomposite was employed to modify the surface of the immunosensor to accelerate the electron transfer rate and improve the immobilization amount of CA19-9 antibodies (Ab). Various techniques, including TEM, SEM and XPS were used to characterize Cu-BTC and nanocomposites. Differential pulse voltammetry (DPV) was used to measure the electrochemical response of the immunosensor in [Fe(CN)6]3-/4-. The signal intensity of the immunosensor was linearly changed upon increasing the concentration of CA19-9 antigen from 10 μU mL-1 to 100 U mL-1, and a detection limit of 4.2 μU mL-1 was achieved. Furthermore, the immunosensor showed good stability, reproducibility and specificity, indicating its potential application in clinical analysis.
Collapse
Affiliation(s)
- Tingting Zhang
- College of Chemistry and Materials Science, Anhui Key Laboratory of Chem-Biosensing, Anhui Normal University, Wuhu 241002, People's Republic of China.
| | - Yan Ma
- College of Chemistry and Materials Science, Anhui Key Laboratory of Chem-Biosensing, Anhui Normal University, Wuhu 241002, People's Republic of China.
| | - Yuzhong Zhang
- College of Chemistry and Materials Science, Anhui Key Laboratory of Chem-Biosensing, Anhui Normal University, Wuhu 241002, People's Republic of China.
| |
Collapse
|
3
|
Rahmani H, Mansouri Majd S, Salimi A, Ghasemi F. Ultrasensitive immunosensor for monitoring of CA 19-9 pancreatic cancer marker using electrolyte-gated TiS 3 nanoribbons field-effect transistor. Talanta 2023; 257:124336. [PMID: 36863296 DOI: 10.1016/j.talanta.2023.124336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2022] [Revised: 02/04/2023] [Accepted: 02/07/2023] [Indexed: 02/12/2023]
Abstract
Measuring CA 19-9 antigen level is critical for early diagnosis of pancreatic cancer, monitoring the treatment process, and predicting disease recurrence. The purpose of this research is to assess the application of novel few-layered TiS3 nanoribbons material as a channel material in electrolyte-gated field-effect transistor immunosensor for rapid detection of CA 19-9 antigen as a cancer marker. Accordingly, TiS3 nanoribbons were produced through liquid-phase exfoliation of as-synthesized TiS3 whiskers in N, N-dimethylformamide. Then, dispersed TiS3 nanoribbons were drop cast onto the FET surface to form an active channel material between source and drain electrodes. Subsequently, the channel surface was modified by utilizing 1-naphthylamine (NA) and glutaraldehyde (GA) to strengthen the binding of monoclonal antibody 19-9 to TiS3 nanoribbons. Spectroscopic and microscopic methods were utilized for comprehensive characterizations. Electrical characterization of electrolyte-gated TiS3 nanoribbons field-effect transistor represented a depletion-mode n-type behavior with field-effect mobility of 0.059 cm2/Vs, current on/off ratio of 10.88 and subthreshold swing (SS) of 450.9 mV/decade. With increasing in CA 19-9 antigen concentration from 1.0 × 10-12 U/mL to 1.0 × 10-5 U/mL, a decrease in the drain current occurred with high sensitivity of 0.04 μA/decade and a detection limit of 1.3 × 10-13 U/mL. Additionally, the proposed TiS3 nanoribbons FET immunosensor exhibited outstanding selectivity, and its good performance was compared with an enzyme-linked immunosorbent assay (ELISA) for spiked real human serum samples. The good and satisfactory obtained results of the proposed immunosensor suggest that the developed platform can be a superb candidate for cancer diagnosis and therapeutic monitoring.
Collapse
Affiliation(s)
- Hedyeh Rahmani
- Department of Chemistry, University of Kurdistan, 66177-15175, Sanandaj, Iran
| | | | - Abdollah Salimi
- Department of Chemistry, University of Kurdistan, 66177-15175, Sanandaj, Iran; Research Center for Nanotechnology, University of Kurdistan, 66177-15175, Sanandaj, Iran.
| | - Foad Ghasemi
- Nanoscale Physics Device Lab (NPDL), Department of Physics, University of Kurdistan, 66177-15175, Sanandaj, Iran
| |
Collapse
|
4
|
Ekwujuru EU, Olatunde AM, Klink MJ, Ssemakalu CC, Chili MM, Peleyeju MG. Electrochemical and Photoelectrochemical Immunosensors for the Detection of Ovarian Cancer Biomarkers. SENSORS (BASEL, SWITZERLAND) 2023; 23:4106. [PMID: 37112447 PMCID: PMC10142013 DOI: 10.3390/s23084106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 03/20/2023] [Accepted: 03/28/2023] [Indexed: 06/19/2023]
Abstract
Photoelectrochemical (PEC) sensing is an emerging technological innovation for monitoring small substances/molecules in biological or non-biological systems. In particular, there has been a surge of interest in developing PEC devices for determining molecules of clinical significance. This is especially the case for molecules that are markers for serious and deadly medical conditions. The increased interest in PEC sensors to monitor such biomarkers can be attributed to the many apparent advantages of the PEC system, including an enhanced measurable signal, high potential for miniaturization, rapid testing, and low cost, amongst others. The growing number of published research reports on the subject calls for a comprehensive review of the various findings. This article is a review of studies on electrochemical (EC) and PEC sensors for ovarian cancer biomarkers in the last seven years (2016-2022). EC sensors were included because PEC is an improved EC; and a comparison of both systems has, expectedly, been carried out in many studies. Specific attention was given to the different markers of ovarian cancer and the EC/PEC sensing platforms developed for their detection/quantification. Relevant articles were sourced from the following databases: Scopus, PubMed Central, Web of Science, Science Direct, Academic Search Complete, EBSCO, CORE, Directory of open Access Journals (DOAJ), Public Library of Science (PLOS), BioMed Central (BMC), Semantic Scholar, Research Gate, SciELO, Wiley Online Library, Elsevier and SpringerLink.
Collapse
Affiliation(s)
- Ezinne U. Ekwujuru
- Department of Biotechnology and Chemistry, Vaal University of Technology, Vanderbijlpark 1911, South Africa
| | | | - Michael J. Klink
- Department of Biotechnology and Chemistry, Vaal University of Technology, Vanderbijlpark 1911, South Africa
| | - Cornelius C. Ssemakalu
- Department of Biotechnology and Chemistry, Vaal University of Technology, Vanderbijlpark 1911, South Africa
| | - Muntuwenkosi M. Chili
- Department of Biotechnology and Chemistry, Vaal University of Technology, Vanderbijlpark 1911, South Africa
- Centre for Academic Development, Vaal University of Technology, Vanderbijlpark 1911, South Africa
| | - Moses G. Peleyeju
- Department of Biotechnology and Chemistry, Vaal University of Technology, Vanderbijlpark 1911, South Africa
- Centre for Academic Development, Vaal University of Technology, Vanderbijlpark 1911, South Africa
| |
Collapse
|
5
|
Yan Z, Xing J, He R, Guo Q, Li J. Probe-Integrated Label-Free Electrochemical Immunosensor Based on Binary Nanocarbon Composites for Detection of CA19-9. Molecules 2022; 27:molecules27206778. [PMID: 36296370 PMCID: PMC9607002 DOI: 10.3390/molecules27206778] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Revised: 09/25/2022] [Accepted: 10/01/2022] [Indexed: 11/16/2022] Open
Abstract
Convenient and sensitive detection of tumor biomarkers is crucial for the early diagnosis and treatment of cancer. Herein, we present a probe-integrated and label-free electrochemical immunosensor based on binary nanocarbon composites and surface-immobilized methylene blue (MB) redox probes for detection of carbohydrate antigen 199 (CA19-9), which is closely associated with gastric malignancies. Nanocarbon composites consisting of electrochemically reduced graphene oxides and carbon nanotubes (ErGO-CNT) are electrodeposited onto an indium tin oxide (ITO) electrode surface to form a 3D nanocomposite film, which could provide high surface area to immobilize abundant MB probes, facilitate the electron transfer of MB, and therefore, improve sensitivity. Polydopamine (PDA) served as a bifunctional linker is able to immobilize anti-CA19-9 antibodies and stabilize the inner probe, conferring the sensing interface with specific recognition capacity. Electrochemical detection of CA19-9 is achieved based on the decrease of the redox signal of MB after specific binding of CA19-9 with a wide linear range of 0.1 mU/mL to 100 U/mL and a limit of detection (LOD) of 0.54 nU/mL (S/N = 3). The constructed electrochemical immunosensor has good selectivity, repeatability, reproducibility, and stability. Furthermore, determination of CA19-9 in human serum samples is also realized.
Collapse
Affiliation(s)
- Zhengzheng Yan
- General Surgery Department, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan 030032, China
| | - Jun Xing
- Department of Breast Surgery, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan 030032, China
- Correspondence:
| | - Ruochong He
- General Surgery Department, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan 030032, China
| | - Qinping Guo
- General Surgery Department, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan 030032, China
| | - Ji Li
- General Surgery Department, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan 030032, China
| |
Collapse
|
6
|
Ilie-Mihai RM, Stefan-van Staden RI, van Staden J(KOOSF. Review—Progress in Electroanalysis of p53, CEA, and CA19–9. JOURNAL OF THE ELECTROCHEMICAL SOCIETY 2022; 169:037518. [DOI: 10.1149/1945-7111/ac5cea] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
Abstract
Screening tests for panels of biomarkers such as the panel comprising p53, CEA, and CA19–9 facilitated early diagnosis of cancers and improvement of the quality of life. In this review, diverse electrochemical sensors used for the assay of p53, CEA, and CA 19–9 in biological samples are shown. Different methods of analysis such as differential pulse voltammetry, electrochemical impendance spectroscopy, chronoamperometry, and stochastic method were used for the assay of one biomarker (differential pulse voltammetry, chronoamperometry) or for the assay of a panel of biomarkers comprising p53, CA19–9, and CEA using stochastic method. The lowest limits of determination were obtained using the stochastic method; they were of fg ml−1/fU ml−1 magnitude order.
Collapse
|
7
|
Yola ML, Atar N. Carbohydrate antigen 19-9 electrochemical immunosensor based on 1D-MoS2 nanorods/LiNb3O8 and polyoxometalate-incorporated gold nanoparticles. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106643] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
8
|
Zhang C, Zhang N, Xu Y, Feng J, Yao T, Wang F, Ma Z, Han H. Fenton reaction-mediated dual-attenuation of signal for ultrasensitive amperometric immunoassay. Biosens Bioelectron 2021; 178:113009. [PMID: 33493899 DOI: 10.1016/j.bios.2021.113009] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 01/07/2021] [Accepted: 01/15/2021] [Indexed: 12/20/2022]
Abstract
In order to alter the complexion of immunoprobe with large impedance as negative factor in sensitivity of amperometric immunosensor, a strategy of Fenton reaction-mediated dual-attenuation of signal was proposed. Herein, metal-polydopamine-Fe3+ composite with the ability of Fenton reaction was initially prepared as immunoprobe for an ultrasensitive immunoassay. The polymerization of dopamine occurred on the surface of ZIF-67 to gain the metal-polydopamine shell, which possessed rich functional groups, negative charge and high specific surface. Then the prepared functional shell was further used to absorb Fe3+ and immobilize labeling antibody as immunoprobe, which was used to construct a sandwich type immunosensor. With addition of H2O2 and aniline, Fenton reaction was triggered to produce hydroxyl radicals, which can not only decrease the current value by degrading methylene blue molecules, but also further initiate aniline to polymerize into non-conductive polyaniline for successive abatement of signal intensity. Therefore, the dual-attenuation of signal model rendered the immunoprobe into a favorable factor and synchronously enhance sensitivity. Expectedly, the detection performance with a linear range from 1.0 × 10-4-100 ng mL-1 and ultralow detection limit of 9.07 × 10-5 ng mL-1 toward neuron-specific enolase was obtained under optimal conditions. This work offered a novel tactic for enhancing sensitivity of immunosensor through the preparation of functional immunoprobe and its rational utilization as signal enhancer.
Collapse
Affiliation(s)
- Chi Zhang
- Department of Chemistry, Capital Normal University, Beijing, 100048, China
| | - Nana Zhang
- Department of Chemistry, Capital Normal University, Beijing, 100048, China
| | - Yang Xu
- Department of Chemistry, Capital Normal University, Beijing, 100048, China
| | - Jiejie Feng
- Department of Chemistry, Capital Normal University, Beijing, 100048, China
| | - Tao Yao
- Department of Chemistry, Capital Normal University, Beijing, 100048, China
| | - Fei Wang
- Department of Chemistry, Capital Normal University, Beijing, 100048, China
| | - Zhanfang Ma
- Department of Chemistry, Capital Normal University, Beijing, 100048, China.
| | - Hongliang Han
- Department of Chemistry, Capital Normal University, Beijing, 100048, China.
| |
Collapse
|
9
|
Electrochemical biosensors for measurement of colorectal cancer biomarkers. Anal Bioanal Chem 2021; 413:2407-2428. [PMID: 33666711 DOI: 10.1007/s00216-021-03197-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 01/15/2021] [Accepted: 01/23/2021] [Indexed: 02/06/2023]
Abstract
Colorectal cancer (CRC) is associated with one of the highest rates of mortality among cancers worldwide. The early detection and management of CRC is imperative. Biomarkers play an important role in CRC screening tests, CRC treatment, and prognosis and clinical management; thus rapid and sensitive detection of biomarkers is helpful for early detection of CRC. In recent years, electrochemical biosensors for detecting CRC biomarkers have been widely investigated. In this review, different electrochemical detection methods for CRC biomarkers including immunosensors, aptasensors, and genosensors are summarized. Further, representative examples are provided that demonstrate the advantages of electrochemical sensors modified by various nanomaterials. Finally, the limitations and prospects of biomarkers and electrochemical sensors in detection are also discussed. Graphical abstract.
Collapse
|
10
|
Zhang X, Yang P, Yang B, Bai Y, Liu W, Zhang Y. Evaluation of synergistic effect from Ag-AgCl 1/3Br 1/3I 1/3 composite on photocatalytic degradation the oil field pollutants. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2021; 247:119029. [PMID: 33120123 DOI: 10.1016/j.saa.2020.119029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Revised: 09/27/2020] [Accepted: 09/29/2020] [Indexed: 06/11/2023]
Abstract
A series of Ag/AgX (X = Cl, Br, I; X = Cl, Br, or X = Cl, I, or X = Br, I; X = Cl, Br, and I) composite photocatalysts were synthesized via a facile photoreduction. The several characterization methods of X-ray diffraction (XRD), energy dispersive X-ray spectrometry (EDS) mapping and X-ray photoelectron spectroscopy (XPS) were characterized the samples. Through evaluation the photocatalytic activity of degradation rhodamine, methyl orange, and phenol, Ag-AgCl1/3Br1/3I1/3 exhibited the superior selective photocatalytic activities than other photocatalysts. The reason for improved photocatalytic property of Ag-AgCl1/3Br1/3I1/3 was attributed to the multifarious halogen atoms with the synergistic effect and the surface plasmon resonance (SPR) effect of Ag0. Furthermore, the recycle experiments were conducted to reveal the stability and reusability, the trapping experiments confirmed the active species of Ag-AgCl1/3Br1/3I1/3.
Collapse
Affiliation(s)
- Xu Zhang
- School of Petroleum and Natural Gas Engineering, Chongqing University of Science and Technology, Chongqing 401331, China
| | - Ping Yang
- Sichuan Province Academy of Industrial Environmental Monitoring, Chengdu 610045, China; State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, School of Oil & Natural Gas Engineering, Southwest Petroleum University, Chengdu 610500, China.
| | - Bo Yang
- College of electrical and mechanical engineering, Southwest Petroleum University, Chengdu 610500, China
| | - Yang Bai
- State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, School of Oil & Natural Gas Engineering, Southwest Petroleum University, Chengdu 610500, China.
| | - Weihua Liu
- School of Petroleum and Natural Gas Engineering, Chongqing University of Science and Technology, Chongqing 401331, China.
| | - Yi Zhang
- National and Local Joint Engineering Research Center of Shale Gas Exploration and Development, Chongqing 401120, China; Institute of Geology and Mineral Resources, Chongqing 401120, China
| |
Collapse
|
11
|
Sensing and Interaction of His-Tagged CA19-9 Antigen with Graphene-Modified Electrodes. CHEMOSENSORS 2020. [DOI: 10.3390/chemosensors8040112] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The electrochemical oxidation of CA19-9 tagged with L-Histidine (CA199-His) was investigated for the first time with screen-printed electrodes (DS) modified with graphene oxide (DS/GO) or thermally reduced graphene oxide (DS/TRGO). Successive cyclic voltammograms (CV) measurements performed with bare and DS/TRGO electrodes proved that the intensity of the oxidation peak (I peak) is time-dependent. In fact, the oxidation signal increased over time, reached a maximum and then decreased due to the saturation of the surface with CA199-His molecules. The interaction of CA199-His with GO, TRGO, or graphite was additionally studied by isothermal calorimetry, a useful tool for accessing information regarding the biomolecule adsorption on graphene surface. The adsorption of CA199-His on TRGO was generating a higher heat, suggesting quantitative and efficient interactions. At the same time, in the case of TRGO, the saturation was not reached, indicating the existence of more free binding sites than in the case of GO and graphite. As such, the carbohydrate marker CA199-His showed a higher affinity for the TRGO surface than for the graphite or GO surfaces. The lack of saturation in the case of TRGO may indicate a continuous structural modification of the antigen when interacting with the graphene surface.
Collapse
|