1
|
Wang Y, Zhang G, Xiao X, Shu X, Fei D, Guang Y, Zhou Y, Lai W. High-Performance Fluorescent Microspheres Based on Fluorescence Resonance Energy Transfer Mode for Lateral Flow Immunoassays. Anal Chem 2023; 95:17860-17867. [PMID: 38050676 DOI: 10.1021/acs.analchem.3c03986] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/06/2023]
Abstract
The label with a large Stokes shift and strong fluorescence properties could improve the sensitivity of the lateral flow immunoassay (LFIA). Herein, two aggregation-induced emission (AIE) luminogens with spectral overlap were encapsulated in polymers by using the microemulsion method as a label, and the construction of a fluorescence resonance energy transfer mode was further verified via theoretical calculation and spectral analysis. Satisfactorily, the doped AIE polymer microspheres (DAIEPMs) exhibited a large Stokes shift of 285 nm and a 10.8-fold fluorescence enhancement compared to those of the AIEPMs loaded with acceptors. Benefiting from the excellent optical performance, DAIEPMs were applied to the LFIA for sensitive detection of chlorothalonil, which is an organochlorine pesticide. The limit of detection of the proposed DAIEPMs-LFIA was 1.2 pg/mL, which was 4.8-fold and 11.6-fold lower than those of quantum dot bead LFIA and gold nanoparticle LFIA, respectively. This work provides a new strategy to improve the optical properties of fluorescent materials and construct a sensitive and reliable detection platform.
Collapse
Affiliation(s)
- Yumeng Wang
- State Key Laboratory of Food Science and Resources, Nanchang University, Nanchang 330047, China
| | - Gan Zhang
- State Key Laboratory of Food Science and Resources, Nanchang University, Nanchang 330047, China
| | - Xiaoyue Xiao
- State Key Laboratory of Food Science and Resources, Nanchang University, Nanchang 330047, China
| | - Xinhui Shu
- State Key Laboratory of Food Science and Resources, Nanchang University, Nanchang 330047, China
| | - Dan Fei
- Ministry of Agriculture and Rural Affairs of the People's Republic of China, Institute for Quality & Safety and Standards of Agricultural Products Research, Jiangxi Academy of Agricultural Sciences, Nanchang 330200, China
| | - Yelan Guang
- Ministry of Agriculture and Rural Affairs of the People's Republic of China, Institute for Quality & Safety and Standards of Agricultural Products Research, Jiangxi Academy of Agricultural Sciences, Nanchang 330200, China
| | - Yaomin Zhou
- Ministry of Agriculture and Rural Affairs of the People's Republic of China, Institute for Quality & Safety and Standards of Agricultural Products Research, Jiangxi Academy of Agricultural Sciences, Nanchang 330200, China
| | - Weihua Lai
- State Key Laboratory of Food Science and Resources, Nanchang University, Nanchang 330047, China
| |
Collapse
|
2
|
Satta S, Rockwood SJ, Wang K, Wang S, Mozneb M, Arzt M, Hsiai TK, Sharma A. Microfluidic Organ-Chips and Stem Cell Models in the Fight Against COVID-19. Circ Res 2023; 132:1405-1424. [PMID: 37167356 PMCID: PMC10171291 DOI: 10.1161/circresaha.122.321877] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
SARS-CoV-2, the virus underlying COVID-19, has now been recognized to cause multiorgan disease with a systemic effect on the host. To effectively combat SARS-CoV-2 and the subsequent development of COVID-19, it is critical to detect, monitor, and model viral pathogenesis. In this review, we discuss recent advancements in microfluidics, organ-on-a-chip, and human stem cell-derived models to study SARS-CoV-2 infection in the physiological organ microenvironment, together with their limitations. Microfluidic-based detection methods have greatly enhanced the rapidity, accessibility, and sensitivity of viral detection from patient samples. Engineered organ-on-a-chip models that recapitulate in vivo physiology have been developed for many organ systems to study viral pathology. Human stem cell-derived models have been utilized not only to model viral tropism and pathogenesis in a physiologically relevant context but also to screen for effective therapeutic compounds. The combination of all these platforms, along with future advancements, may aid to identify potential targets and develop novel strategies to counteract COVID-19 pathogenesis.
Collapse
Affiliation(s)
- Sandro Satta
- Division of Cardiology and Department of Bioengineering, School of Engineering (S.S., K.W., S.W., T.K.H.), University of California, Los Angeles
- Division of Cardiology, Department of Medicine, School of Medicine (S.S., K.W., S.W., T.K.H.), University of California, Los Angeles
- Department of Medicine, Greater Los Angeles VA Healthcare System, California (S.S., K.W., S.W., T.K.H.)
| | - Sarah J. Rockwood
- Stanford University Medical Scientist Training Program, Palo Alto, CA (S.J.R.)
| | - Kaidong Wang
- Division of Cardiology and Department of Bioengineering, School of Engineering (S.S., K.W., S.W., T.K.H.), University of California, Los Angeles
- Division of Cardiology, Department of Medicine, School of Medicine (S.S., K.W., S.W., T.K.H.), University of California, Los Angeles
- Department of Medicine, Greater Los Angeles VA Healthcare System, California (S.S., K.W., S.W., T.K.H.)
| | - Shaolei Wang
- Division of Cardiology and Department of Bioengineering, School of Engineering (S.S., K.W., S.W., T.K.H.), University of California, Los Angeles
- Division of Cardiology, Department of Medicine, School of Medicine (S.S., K.W., S.W., T.K.H.), University of California, Los Angeles
- Department of Medicine, Greater Los Angeles VA Healthcare System, California (S.S., K.W., S.W., T.K.H.)
| | - Maedeh Mozneb
- Board of Governors Regenerative Medicine Institute (M.M., M.A., A.S.), Cedars-Sinai Medical Center, Los Angeles, CA
- Smidt Heart Institute (M.M., M.A., A.S.), Cedars-Sinai Medical Center, Los Angeles, CA
- Department of Biomedical Sciences (M.M., M.A., A.S.), Cedars-Sinai Medical Center, Los Angeles, CA
- Cancer Institute (M.M., M.A., A.S.), Cedars-Sinai Medical Center, Los Angeles, CA
| | - Madelyn Arzt
- Board of Governors Regenerative Medicine Institute (M.M., M.A., A.S.), Cedars-Sinai Medical Center, Los Angeles, CA
- Smidt Heart Institute (M.M., M.A., A.S.), Cedars-Sinai Medical Center, Los Angeles, CA
- Department of Biomedical Sciences (M.M., M.A., A.S.), Cedars-Sinai Medical Center, Los Angeles, CA
- Cancer Institute (M.M., M.A., A.S.), Cedars-Sinai Medical Center, Los Angeles, CA
| | - Tzung K. Hsiai
- Division of Cardiology and Department of Bioengineering, School of Engineering (S.S., K.W., S.W., T.K.H.), University of California, Los Angeles
- Division of Cardiology, Department of Medicine, School of Medicine (S.S., K.W., S.W., T.K.H.), University of California, Los Angeles
- Department of Medicine, Greater Los Angeles VA Healthcare System, California (S.S., K.W., S.W., T.K.H.)
| | - Arun Sharma
- Board of Governors Regenerative Medicine Institute (M.M., M.A., A.S.), Cedars-Sinai Medical Center, Los Angeles, CA
- Smidt Heart Institute (M.M., M.A., A.S.), Cedars-Sinai Medical Center, Los Angeles, CA
- Department of Biomedical Sciences (M.M., M.A., A.S.), Cedars-Sinai Medical Center, Los Angeles, CA
- Cancer Institute (M.M., M.A., A.S.), Cedars-Sinai Medical Center, Los Angeles, CA
| |
Collapse
|
3
|
Yu Q, Zheng M, Li M, Jiang R, Zhu H, Guo H, Sun H, Liu M. Competitive fluorescent immunoassay for the ultrasensitive determination of amyloid beta peptide1-42 based on Ag@SiO 2@N, S-GQD nanocomposites. Mikrochim Acta 2023; 190:194. [PMID: 37103596 DOI: 10.1007/s00604-023-05774-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Accepted: 01/30/2023] [Indexed: 04/28/2023]
Abstract
A competitive fluorescent immunoassay is described for the ultrasensitive determination of amyloid beta peptide1-42 (Aβ1-42), a biomarker for early diagnosis of Alzheimer's disease. N, S-doped graphene quantum dots (N, S-GQDs) were freely assembled on the surface of Ag@SiO2 nanoparticles to obtain a composite (Ag@SiO2@N, S-GQD nanocomposite), which was successfully prepared and characterized. By theoretical study, the optical properties of nanocomposites are improved compared with GQDs, due to the advantages of combining N, S co-doping and metal-enhanced fluorescence (MEF) effect of Ag NPs. In addition, Aβ1-42 was modified by Ag@SiO2@N, S-GQDs to prepare a probe with high photoluminescence properties (Ag@SiO2@N, S-GQDs-Aβ1-42). In the presence of Aβ1-42, a competitive reaction towards anti-Aβ1-42 fixed on the ELISA plate was proceeded between Aβ1-42 and Ag@SiO2@N, S-GQDs-Aβ1-42 by specific capture of antigen-antibody. The emission peak of Ag@SiO2@N, S-GQDs-Aβ1-42 (400 nm emission) was used for the quantitative determination of Aβ1-42. Under the optimal conditions, the fluorescent immunoassay exhibited a linear range of 0.32 pg·mL-1-5 ng·mL-1 with a detection limit of 0.098 pg·mL-1. The results show that the immunoassay has good analytical ability and can provide a new method for the clinical determination of Aβ1-42.
Collapse
Affiliation(s)
- Qingjie Yu
- Cooperative Innovation Center of Industrial Fermentation (Ministry of Education & Hubei Province), Wuhan, 430068, China
- Hubei Key Laboratory of Industrial Microbiology, Hubei University of Technology, Wuhan, 430068, China
| | - Meie Zheng
- Cooperative Innovation Center of Industrial Fermentation (Ministry of Education & Hubei Province), Wuhan, 430068, China
- Hubei Key Laboratory of Industrial Microbiology, Hubei University of Technology, Wuhan, 430068, China
| | - Mengjiao Li
- Cooperative Innovation Center of Industrial Fermentation (Ministry of Education & Hubei Province), Wuhan, 430068, China
- Hubei Key Laboratory of Industrial Microbiology, Hubei University of Technology, Wuhan, 430068, China
| | - Rongrong Jiang
- Cooperative Innovation Center of Industrial Fermentation (Ministry of Education & Hubei Province), Wuhan, 430068, China
- Hubei Key Laboratory of Industrial Microbiology, Hubei University of Technology, Wuhan, 430068, China
| | - Hongda Zhu
- Cooperative Innovation Center of Industrial Fermentation (Ministry of Education & Hubei Province), Wuhan, 430068, China
- Hubei Key Laboratory of Industrial Microbiology, Hubei University of Technology, Wuhan, 430068, China
- National "111" Center for Cellular Regulation and Molecular Pharmaceutics, Wuhan, 430068, China
- Key Laboratory of Fermentation Engineering, Ministry of Education, Wuhan, 430068, China
| | - Huiling Guo
- Cooperative Innovation Center of Industrial Fermentation (Ministry of Education & Hubei Province), Wuhan, 430068, China
- Hubei Key Laboratory of Industrial Microbiology, Hubei University of Technology, Wuhan, 430068, China
- National "111" Center for Cellular Regulation and Molecular Pharmaceutics, Wuhan, 430068, China
- Key Laboratory of Fermentation Engineering, Ministry of Education, Wuhan, 430068, China
| | - Hongmei Sun
- Cooperative Innovation Center of Industrial Fermentation (Ministry of Education & Hubei Province), Wuhan, 430068, China
- Hubei Key Laboratory of Industrial Microbiology, Hubei University of Technology, Wuhan, 430068, China
- National "111" Center for Cellular Regulation and Molecular Pharmaceutics, Wuhan, 430068, China
- Key Laboratory of Fermentation Engineering, Ministry of Education, Wuhan, 430068, China
| | - Mingxing Liu
- Cooperative Innovation Center of Industrial Fermentation (Ministry of Education & Hubei Province), Wuhan, 430068, China.
- Hubei Key Laboratory of Industrial Microbiology, Hubei University of Technology, Wuhan, 430068, China.
- National "111" Center for Cellular Regulation and Molecular Pharmaceutics, Wuhan, 430068, China.
- Key Laboratory of Fermentation Engineering, Ministry of Education, Wuhan, 430068, China.
| |
Collapse
|
4
|
Li D, Sun C, Mei X, Yang L. Achieving broad availability of SARS-CoV-2 detections via smartphone-based analysis. Trends Analyt Chem 2023; 158:116878. [PMID: 36506266 PMCID: PMC9728015 DOI: 10.1016/j.trac.2022.116878] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 12/01/2022] [Accepted: 12/06/2022] [Indexed: 12/13/2022]
Abstract
With the development of COVID-19, widely available tests are in great demand. Naked-eye SARS-CoV-2 test kits have recently been developed as home tests, but their sensitivity and accuracy are sometimes limited. Smartphones can convert various signals into digital information, potentially improving the sensitivity and accuracy of these home tests. Herein, we summarize smartphone-based detections for SARS-CoV-2. Optical detections of non-nucleic acids using various sensors and portable imaging systems, as well as nucleic acid analyses based on LAMP, CRISP, CATCH, and biosensors are discussed. Furthermore, different electrochemical detections were compared. We show results obtained using relatively complex equipment, complicated programming procedures, or custom smartphone apps, and describe methods for obtaining information with only simple setups and free software on smartphones. Then, the combined costs of typical smartphone-based detections are evaluated. Finally, the prospect of improving smartphone-based strategies to achieve broad availability of SARS-CoV-2 detection is proposed.
Collapse
Affiliation(s)
- Dan Li
- Jinzhou Medical University, Jinzhou, China
| | - Cai Sun
- AECC Shenyang Liming Aero-Engine Co, Ltd., Shenyang, China
| | - Xifan Mei
- Jinzhou Medical University, Jinzhou, China,Corresponding author
| | - Liqun Yang
- NHC Key Laboratory of Reproductive Health and Medical Genetics (China Medical University), Liaoning Research Institute of Family Planning (The Affiliated Reproductive Hospital of China Medical University), Shenyang, China,Corresponding author
| |
Collapse
|
5
|
Chang H, Jiang M, Zhu Q, Liu A, Wu Y, Li C, Ji X, Gong L, Li S, Chen Z, Kong L, Han L. A novel photoelectrochemical immunosensor based on TiO 2@Bi 2WO 6 hollow microspheres and Ag 2S for sensitive detection of SARS-COV-2 nucleocapsid protein. Microchem J 2022; 182:107866. [PMID: 35971541 PMCID: PMC9365518 DOI: 10.1016/j.microc.2022.107866] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 07/21/2022] [Accepted: 08/04/2022] [Indexed: 11/17/2022]
Abstract
Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-COV-2) is a cluster of β coronaviruses. The 2019 coronavirus disease (COVID-19) caused by SARS-COV-2 is emerging as a global pandemic. Thus, early diagnosis of SARS-COV-2 is essential to prevent severe outbreaks of the disease. In this experiment, a novel label-free photoelectrochemical (PEC) immunosensor was obtained based on silver sulfide (Ag2S) sensitized titanium dioxide@bismuth tungstate (TiO2@Bi2WO6) nanocomposite for quantitative detection of SARS-COV-2 nucleocapsid protein. The constructed TiO2@Bi2WO6 hollow microspheres had large specific surface area and could produce high photocurrent intensity under visible light illumination. Ag2S was in-situ grown on the surface of thioglycolic acid (TGA) modified TiO2@Bi2WO6. In particular, TiO2@Bi2WO6 and Ag2S formed a good energy level match, which could effectively enhance the photocurrent conversion efficiency and strength the photocurrent response. Ascorbic acid (AA) acted as an effective electron donor to effectively eliminate photogenerated holes. Under optimal experimental conditions, the constructed immunosensor presented a supersensitive response to SARS-COV-2 nucleocapsid protein, with a desirable linear relationship ranged from 0.001 to 50 ng/mL for nucleocapsid protein and a lower detection limit of 0.38 pg/mL. The fabricated sensor exhibited a wide linear range, excellent selectivity, specificity and stability, which provided a valuable referential idea for the detection of SARS-COV-2.
Collapse
Affiliation(s)
- Huiqin Chang
- School of Agriculture Engineering and Food Science, Shandong University of Technology, Zibo 255049, PR China
| | - Meng Jiang
- School of Life Sciences, Shandong University of Technology, Zibo 255049, PR China
| | - Qiying Zhu
- School of Life Sciences, Shandong University of Technology, Zibo 255049, PR China
| | - Anqi Liu
- School of Life Sciences, Shandong University of Technology, Zibo 255049, PR China
| | - Yuyin Wu
- School of Agriculture Engineering and Food Science, Shandong University of Technology, Zibo 255049, PR China
| | - Canguo Li
- School of Life Sciences, Shandong University of Technology, Zibo 255049, PR China
| | - Xiangyue Ji
- School of Life Sciences, Shandong University of Technology, Zibo 255049, PR China
| | - Li Gong
- School of Life Sciences, Shandong University of Technology, Zibo 255049, PR China
| | - Shanshan Li
- School of Life Sciences, Shandong University of Technology, Zibo 255049, PR China
| | - Zhiwei Chen
- Institute of Food and Nutrition Science, Shandong University of Technology, Zibo 255049, PR China
| | - Ling Kong
- School of Life Sciences, Shandong University of Technology, Zibo 255049, PR China
| | - Lei Han
- College of Chemistry and Pharmaceutical Sciences, Qingdao Agricultural University, Qingdao 266109, PR China
| |
Collapse
|
6
|
Wu M, Wu S, Wang G, Liu W, Chu LT, Jiang T, Kwong HK, Chow HL, Li IWS, Chen TH. Microfluidic particle dam for direct visualization of SARS-CoV-2 antibody levels in COVID-19 vaccinees. SCIENCE ADVANCES 2022; 8:eabn6064. [PMID: 35658040 PMCID: PMC9166397 DOI: 10.1126/sciadv.abn6064] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Various COVID-19 vaccines are currently deployed, but their immunization varies and decays with time. Antibody level is a potent correlate to immune protection, but its quantitation relies on intensive laboratory techniques. Here, we report a decentralized, instrument-free microfluidic device that directly visualizes SARS-CoV-2 antibody levels. Magnetic microparticles (MMPs) and polystyrene microparticles (PMPs) can bind to SARS-CoV-2 antibodies simultaneously. In a microfluidic chip, this binding reduces the incidence of free PMPs escaping from magnetic separation and shortens PMP accumulation length at a particle dam. This visual quantitative result enables use in either sensitive mode [limit of detection (LOD): 13.3 ng/ml; sample-to-answer time: 70 min] or rapid mode (LOD: 57.8 ng/ml; sample-to-answer time: 20 min) and closely agrees with the gold standard enzyme-linked immunosorbent assay. Trials on 91 vaccinees revealed higher antibody levels in mRNA vaccinees than in inactivated vaccinees and their decay in 45 days, demonstrating the need for point-of-care devices to monitor immune protection.
Collapse
Affiliation(s)
- Minghui Wu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Siying Wu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Gaobo Wang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Wengang Liu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Lok Ting Chu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Tianyi Jiang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Hoi Kwan Kwong
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Hiu Lam Chow
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Iris Wai Sum Li
- HKU-Pasteur Research Pole, The University of Hong Kong, Pokfulam, Hong Kong Special Administrative Region, China
| | - Ting-Hsuan Chen
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, China
- City University of Hong Kong Shenzhen Research Institute, Shenzhen, China
- Corresponding author.
| |
Collapse
|
7
|
Jamiruddin MR, Meghla BA, Islam DZ, Tisha TA, Khandker SS, Khondoker MU, Haq MA, Adnan N, Haque M. Microfluidics Technology in SARS-CoV-2 Diagnosis and Beyond: A Systematic Review. Life (Basel) 2022; 12:649. [PMID: 35629317 PMCID: PMC9146058 DOI: 10.3390/life12050649] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 04/21/2022] [Accepted: 04/25/2022] [Indexed: 12/22/2022] Open
Abstract
With the progression of the COVID-19 pandemic, new technologies are being implemented for more rapid, scalable, and sensitive diagnostics. The implementation of microfluidic techniques and their amalgamation with different detection techniques has led to innovative diagnostics kits to detect SARS-CoV-2 antibodies, antigens, and nucleic acids. In this review, we explore the different microfluidic-based diagnostics kits and how their amalgamation with the various detection techniques has spearheaded their availability throughout the world. Three other online databases, PubMed, ScienceDirect, and Google Scholar, were referred for articles. One thousand one hundred sixty-four articles were determined with the search algorithm of microfluidics followed by diagnostics and SARS-CoV-2. We found that most of the materials used to produce microfluidics devices were the polymer materials such as PDMS, PMMA, and others. Centrifugal force is the most commonly used fluid manipulation technique, followed by electrochemical pumping, capillary action, and isotachophoresis. The implementation of the detection technique varied. In the case of antibody detection, spectrometer-based detection was most common, followed by fluorescence-based as well as colorimetry-based. In contrast, antigen detection implemented electrochemical-based detection followed by fluorescence-based detection, and spectrometer-based detection were most common. Finally, nucleic acid detection exclusively implements fluorescence-based detection with a few colorimetry-based detections. It has been further observed that the sensitivity and specificity of most devices varied with implementing the detection-based technique alongside the fluid manipulation technique. Most microfluidics devices are simple and incorporate the detection-based system within the device. This simplifies the deployment of such devices in a wide range of environments. They can play a significant role in increasing the rate of infection detection and facilitating better health services.
Collapse
Affiliation(s)
| | - Bushra Ayat Meghla
- Department of Microbiology, Jahangirnagar University, Savar, Dhaka 1342, Bangladesh; (B.A.M.); (D.Z.I.); (T.A.T.)
| | - Dewan Zubaer Islam
- Department of Microbiology, Jahangirnagar University, Savar, Dhaka 1342, Bangladesh; (B.A.M.); (D.Z.I.); (T.A.T.)
| | - Taslima Akter Tisha
- Department of Microbiology, Jahangirnagar University, Savar, Dhaka 1342, Bangladesh; (B.A.M.); (D.Z.I.); (T.A.T.)
| | - Shahad Saif Khandker
- Gonoshasthaya-RNA Molecular Diagnostic & Research Center, Dhanmondi, Dhaka 1205, Bangladesh; (S.S.K.); (M.A.H.)
| | - Mohib Ullah Khondoker
- Department of Community Medicine, Gonoshasthaya Samaj Vittik Medical College, Savar, Dhaka 1344, Bangladesh;
| | - Md. Ahsanul Haq
- Gonoshasthaya-RNA Molecular Diagnostic & Research Center, Dhanmondi, Dhaka 1205, Bangladesh; (S.S.K.); (M.A.H.)
| | - Nihad Adnan
- Department of Microbiology, Jahangirnagar University, Savar, Dhaka 1342, Bangladesh; (B.A.M.); (D.Z.I.); (T.A.T.)
| | - Mainul Haque
- The Unit of Pharmacology, Faculty of Medicine and Defence Health, Universiti Pertahanan Nasional Malaysia (National Defence University of Malaysia), Kem Perdana Sugai Besi, Kuala Lumpur 57000, Malaysia
| |
Collapse
|