1
|
Sardanelli F. Contrast-enhanced mammography: a success story with open issues and fascinating perspectives. Eur Radiol 2025:10.1007/s00330-025-11605-1. [PMID: 40266350 DOI: 10.1007/s00330-025-11605-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2025] [Revised: 03/06/2025] [Accepted: 03/21/2025] [Indexed: 04/24/2025]
|
2
|
Hsu JC, Lau KC, Barragan D, Mossburg KJ, Cormode DP, Maidment ADA. Influence of Acquisition Parameters on Silver Sulfide Nanoparticle Contrast in Photon-Counting Digital Mammography: A Phantom Study. ACS APPLIED NANO MATERIALS 2024; 7:4805-4813. [PMID: 39882402 PMCID: PMC11774497 DOI: 10.1021/acsanm.3c05431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/31/2025]
Abstract
Photon-counting mammography is an emerging modality that allows for spectral imaging and provides a differentiation of material compositions. The development of photon-counting mammography-specific contrast agents has yet to be explored. In this study, the contrast, sensitivity, and organ dose between silver sulfide nanoparticles (Ag2S-NPs) and a clinically approved iodinated agent (iopamidol) were investigated using a contrast-embedded gradient ramp phantom and a prototype scanner. For a given agent, the signal intensity increased with concentration, tube voltage (kV), and high bin fraction, while remaining constant with the tube current exposure time product (mAs). Moreover, Ag2S-NPs produced significantly stronger contrast and improved sensitivity compared to iodine, especially when imaged at lower tube energies. Therefore, the use of photon-counting techniques and a silver-based contrast agent may markedly increase the contrast and contrast-to-noise ratios or reduce the radiation dose for contrast-enhanced mammography. Silver may be better suited than iodine for contrast agent development for spectral photon-counting mammography.
Collapse
Affiliation(s)
- Jessica C Hsu
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Kristen C Lau
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Diego Barragan
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Katherine J Mossburg
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - David P Cormode
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Andrew D A Maidment
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| |
Collapse
|
3
|
Balamou C, Koïvogui A, Zysman K, Rodrigue CM, Rymzhanova R. Impact of tomosynthesis on the evolution of the cancer detection rate in the French National Breast Cancer Screening Program. Public Health 2022; 210:65-73. [PMID: 35870323 DOI: 10.1016/j.puhe.2022.06.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 05/09/2022] [Accepted: 06/13/2022] [Indexed: 11/27/2022]
Abstract
OBJECTIVES This study aims to evaluate the cancer detection rate in French National Breast Cancer Screening Program, especially the cancer detection rate during second reading session (Reading 2) based on digital technologies used in radiology centres. STUDY DESIGN This was an analytical and descriptive study. METHODS Cancer detection rate was estimated by the ratio between the number of cancers detected and the number of women screened. The positive predictive value (PPV) was estimated as cancer detection rate among abnormal Reading 2. The relationship between Reading 2's PPV and the predictive factors was evaluated using multilevel mixed-effects logistic regression. RESULTS A total of 1,380,006 digital mammograms were retained in the analysis between 2010 and 2019. Cancer detection rate represented 7.8‰ at first reading session (Reading 1) and 0.5‰ at Reading 2. Cancer detection rate is significantly associated with the use of tomosynthesis (P < 0.001) at Reading 1, and differences appear within different tomosynthesis brands (P = 0.007). Reading 2's PPV differs significantly according on technologies used by first Reader (P < 0.004). Nevertheless, Reading 2 has 1.9 (1.5-2.4) more likely to predict a cancer with the presence of previous mammogram compared with those without previous images. CONCLUSION Using tomosynthesis technology improves cancer detection rate at Reading 1, even if differences are noticeable between brands. Using tomosynthesis technology at Reading 1 reduces Reading 2's PPV and cancer detection rate at Reading 2.
Collapse
Affiliation(s)
- C Balamou
- Centre Régional de Coordination des Dépistages des Cancers en Auvergne-Rhône-Alpes, Site de L'Ain, 01000 Bourg-en-Bresse, France.
| | - A Koïvogui
- Centre Régional de Coordination des Dépistages des Cancers en Ile-de-France, Site de Seine-Saint-Denis, 93146 Bondy, France.
| | - K Zysman
- Centre Régional de Coordination des Dépistages des Cancers en Auvergne-Rhône-Alpes, Site de L'Isère, 38240 Meylan, France.
| | - C M Rodrigue
- Centre Régional de Coordination des Dépistages des Cancers en Auvergne-Rhône-Alpes, Site de L'Ain, 01000 Bourg-en-Bresse, France.
| | - R Rymzhanova
- Centre Régional de Coordination des Dépistages des Cancers en Bourgogne-Franche-Comté, Site Franche-Comté, 25000 Besançon, France
| |
Collapse
|
4
|
Svahn TM, Gordon R, Ast JC, Riffel J, Hartbauer M. COMPARISON OF PHOTON-COUNTING AND FLAT-PANEL DIGITAL MAMMMOGRAPHY FOR THE PURPOSE OF 3D IMAGING USING A NOVEL IMAGE PROCESSING METHOD. RADIATION PROTECTION DOSIMETRY 2021; 195:454-461. [PMID: 34323279 DOI: 10.1093/rpd/ncab104] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Revised: 05/29/2021] [Accepted: 06/10/2021] [Indexed: 06/13/2023]
Abstract
The purpose of the present work was to compare the quality of low-dose projections from a photon-counting with a flat-panel system, and to evaluate a novel image processing method. Images were acquired of phantoms in both systems at average glandular doses ranging from ~ 0.15 to 1.4 mGy. Automated detection of low-contrast features and modulation transfer functions were evaluated in phantom images. The novel image processing method was compared with standard processing in a series of clinical cases. At low-doses (~0.15) the photon-counting system out-performed the flat-panel system with a much higher detectability of low-contrast features. The novel algorithm was superior to both manufacturers' processing in terms of conspicuity of soft-tissue lesions (p > 0.05), whereas it was not significantly different in calcification conspicuity. Photon-counting should allow more low-dose projections to be acquired at the same total dose. The novel image enhancer can help to further increase the image quality.
Collapse
Affiliation(s)
- T M Svahn
- Centre for Research and Development, Uppsala University/Region Gävleborg, 801 88 Gävle, Sweden
| | - R Gordon
- Gulf Marine Specimen Laboratory, Panacea, FL 32346, USA
- C.S. Mott Center for Human Growth & Development, Department of Obstetrics & Gynecology, Wayne State University, Detroit, MI 48201, USA
| | - J C Ast
- Department of Organismal Biology, 752 36 Uppsala University, Uppsala, Sweden
| | - J Riffel
- Department of Clinical Radiology and Nuclear Medicine, 68167 Mannheim, University of Heidelberg, Germany
| | - M Hartbauer
- Institute of Biology, Universitätsplatz 2, University of Graz, 8010 Graz, Austria
| |
Collapse
|
5
|
Ghammraoui B, Gkoumas S, Glick SJ. Characterization of a GaAs photon-counting detector for mammography. J Med Imaging (Bellingham) 2021; 8:033504. [PMID: 34179217 PMCID: PMC8217962 DOI: 10.1117/1.jmi.8.3.033504] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Accepted: 06/04/2021] [Indexed: 11/14/2022] Open
Abstract
Purpose: The purpose of this study was to evaluate the potential of a prototype gallium arsenide (GaAs) photon-counting detector (PCD) for imaging of the breast. Approach: First, the contrast-to-noise ratio (CNR) using different aluminum/poly(methyl methacrylate) (PMMA) phantoms of different thicknesses were measured. Second, microcalcification detection accuracy using a receiver operating characteristic study with three observers reading an ensemble of images was measured. Finally, the feasibility of using a GaAs system with two energy bins for contrast-enhanced mammography was investigated. Results: For the first two studies, the GaAs detector was compared with a commercial mammography system. The CNR was estimated by imaging 18-, 36-, and 110 - μ m -thick aluminum targets placed on top of 6 cm of PMMA plates and was found to be similar or better over a range of exposures. We observed a similar performance of detecting microcalcifications with the GaAs detector over a range of clinically applicable dose levels with a small increase at lower dose levels. The results also showed that contrast-enhanced spectral mammography using a GaAs PCD is feasible and beneficial. Conclusions: Results from this study suggest that performance with this new detector seems either slightly improved or equivalent to a commercial mammography system that used an energy-integrated detector. No attempt at optimizing exposure techniques for the GaAs detector was performed. Further research is needed to determine optimal acquisition parameters for the GaAs detector and to develop more sophisticated material decomposition algorithms that promise to provide improved quantitative estimates of iodine uptake.
Collapse
Affiliation(s)
- Bahaa Ghammraoui
- U.S. Food and Drug Administration, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Silver Spring, Maryland, United States
| | | | - Stephen J. Glick
- U.S. Food and Drug Administration, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Silver Spring, Maryland, United States
| |
Collapse
|
6
|
Hsu JC, Nieves LM, Betzer O, Sadan T, Noël PB, Popovtzer R, Cormode DP. Nanoparticle contrast agents for X-ray imaging applications. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2020; 12:e1642. [PMID: 32441050 DOI: 10.1002/wnan.1642] [Citation(s) in RCA: 58] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Revised: 04/13/2020] [Accepted: 04/14/2020] [Indexed: 12/12/2022]
Abstract
X-ray imaging is the most widely used diagnostic imaging method in modern medicine and several advanced forms of this technology have recently emerged. Iodinated molecules and barium sulfate suspensions are clinically approved X-ray contrast agents and are widely used. However, these existing contrast agents provide limited information, are suboptimal for new X-ray imaging techniques and are developing safety concerns. Thus, over the past 15 years, there has been a rapid growth in the development of nanoparticles as X-ray contrast agents. Nanoparticles have several desirable features such as high contrast payloads, the potential for long circulation times, and tunable physicochemical properties. Nanoparticles have also been used in a range of biomedical applications such as disease treatment, targeted imaging, and cell tracking. In this review, we discuss the principles behind X-ray contrast generation and introduce new types of X-ray imaging modalities, as well as potential elements and chemical compositions that are suitable for novel contrast agent development. We focus on the progress in nanoparticle X-ray contrast agents developed to be renally clearable, long circulating, theranostic, targeted, or for cell tracking. We feature agents that are used in conjunction with the newly developed multi-energy computed tomography and mammographic imaging technologies. Finally, we offer perspectives on current limitations and emerging research topics as well as expectations for the future development of the field. This article is categorized under: Diagnostic Tools > in vivo Nanodiagnostics and Imaging Nanotechnology Approaches to Biology > Nanoscale Systems in Biology.
Collapse
Affiliation(s)
- Jessica C Hsu
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.,Department of Bioengineering, School of Engineering and Applied Science of the University of Pennsylvania, Pennsylvania, USA
| | - Lenitza M Nieves
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.,Department of Biochemistry and Molecular Biophysics, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Oshra Betzer
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel
| | - Tamar Sadan
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel
| | - Peter B Noël
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Rachela Popovtzer
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel
| | - David P Cormode
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.,Department of Bioengineering, School of Engineering and Applied Science of the University of Pennsylvania, Pennsylvania, USA.,Department of Biochemistry and Molecular Biophysics, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
7
|
Sisniega A, Zbijewski W, Stayman JW, Xu J, Taguchi K, Fredenberg E, Lundqvist M, Siewerdsen JH. Volumetric CT with sparse detector arrays (and application to Si-strip photon counters). Phys Med Biol 2016; 61:90-113. [PMID: 26611740 PMCID: PMC5070652 DOI: 10.1088/0031-9155/61/1/90] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Novel x-ray medical imaging sensors, such as photon counting detectors (PCDs) and large area CCD and CMOS cameras can involve irregular and/or sparse sampling of the detector plane. Application of such detectors to CT involves undersampling that is markedly different from the commonly considered case of sparse angular sampling. This work investigates volumetric sampling in CT systems incorporating sparsely sampled detectors with axial and helical scan orbits and evaluates performance of model-based image reconstruction (MBIR) with spatially varying regularization in mitigating artifacts due to sparse detector sampling. Volumetric metrics of sampling density and uniformity were introduced. Penalized-likelihood MBIR with a spatially varying penalty that homogenized resolution by accounting for variations in local sampling density (i.e. detector gaps) was evaluated. The proposed methodology was tested in simulations and on an imaging bench based on a Si-strip PCD (total area 5 cm × 25 cm) consisting of an arrangement of line sensors separated by gaps of up to 2.5 mm. The bench was equipped with translation/rotation stages allowing a variety of scanning trajectories, ranging from a simple axial acquisition to helical scans with variable pitch. Statistical (spherical clutter) and anthropomorphic (hand) phantoms were considered. Image quality was compared to that obtained with a conventional uniform penalty in terms of structural similarity index (SSIM), image uniformity, spatial resolution, contrast, and noise. Scan trajectories with intermediate helical width (~10 mm longitudinal distance per 360° rotation) demonstrated optimal tradeoff between the average sampling density and the homogeneity of sampling throughout the volume. For a scan trajectory with 10.8 mm helical width, the spatially varying penalty resulted in significant visual reduction of sampling artifacts, confirmed by a 10% reduction in minimum SSIM (from 0.88 to 0.8) and a 40% reduction in the dispersion of SSIM in the volume compared to the constant penalty (both penalties applied at optimal regularization strength). Images of the spherical clutter and wrist phantoms confirmed the advantages of the spatially varying penalty, showing a 25% improvement in image uniformity and 1.8 × higher CNR (at matched spatial resolution) compared to the constant penalty. The studies elucidate the relationship between sampling in the detector plane, acquisition orbit, sampling of the reconstructed volume, and the resulting image quality. They also demonstrate the benefit of spatially varying regularization in MBIR for scenarios with irregular sampling patterns. Such findings are important and integral to the incorporation of a sparsely sampled Si-strip PCD in CT imaging.
Collapse
Affiliation(s)
- A Sisniega
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, USA
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Yasuda N, Suzuki H, Katafuchi T. Development of a single-photon-counting camera with use of a triple-stacked micro-channel plate. Radiol Phys Technol 2015; 9:88-94. [PMID: 26486629 DOI: 10.1007/s12194-015-0337-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2015] [Revised: 10/03/2015] [Accepted: 10/05/2015] [Indexed: 11/26/2022]
Abstract
At the quantum-mechanical level, all substances (not merely electromagnetic waves such as light and X-rays) exhibit wave–particle duality. Whereas students of radiation science can easily understand the wave nature of electromagnetic waves, the particle (photon) nature may elude them. Therefore, to assist students in understanding the wave–particle duality of electromagnetic waves, we have developed a photon-counting camera that captures single photons in two-dimensional images. As an image intensifier, this camera has a triple-stacked micro-channel plate (MCP) with an amplification factor of 10(6). The ultra-low light of a single photon entering the camera is first converted to an electron through the photoelectric effect on the photocathode. The electron is intensified by the triple-stacked MCP and then converted to a visible light distribution, which is measured by a high-sensitivity complementary metal oxide semiconductor image sensor. Because it detects individual photons, the photon-counting camera is expected to provide students with a complete understanding of the particle nature of electromagnetic waves. Moreover, it measures ultra-weak light that cannot be detected by ordinary low-sensitivity cameras. Therefore, it is suitable for experimental research on scintillator luminescence, biophoton detection, and similar topics.
Collapse
|
9
|
Radiation exposure of contrast-enhanced spectral mammography compared with full-field digital mammography. Invest Radiol 2015; 49:659-65. [PMID: 24872005 DOI: 10.1097/rli.0000000000000068] [Citation(s) in RCA: 75] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Contrast-enhanced spectral mammography (CESM) shows promising initial results but comes at the cost of increased dose as compared with full-field digital mammography (FFDM). We aimed to quantitatively assess the dose increase of CESM in comparison with FFDM. MATERIALS AND METHODS Radiation exposure-related data (such as kilovoltage, compressed breast thickness, glandularity, entrance skin air kerma (ESAK), and average glandular dose (AGD) were retrieved for 47 CESM and 715 FFDM patients. All examinations were performed on 1 mammography unit. Radiation dose values reported by the unit were validated by phantom measurements. Descriptive statistics of the patient data were generated using a statistical software package. RESULTS Dose values reported by the mammography unit were in good qualitative agreement with those of phantom measurements. Mean ESAK was 10.5 mGy for a CESM exposure and 7.46 mGy for an FFDM exposure. Mean AGD for a CESM exposure was 2.80 mGy and 1.55 mGy for an FFDM exposure. CONCLUSIONS Compared with our institutional FFDM, the AGD of a single CESM exposure is increased by 1.25 mGy (+81%), whereas ESAK is increased by 3.07 mGy (+41%). Dose values of both techniques meet the recommendations for maximum dose in mammography.
Collapse
|
10
|
Dendumrongsup T, Plumb AA, Halligan S, Fanshawe TR, Altman DG, Mallett S. Multi-reader multi-case studies using the area under the receiver operator characteristic curve as a measure of diagnostic accuracy: systematic review with a focus on quality of data reporting. PLoS One 2014; 9:e116018. [PMID: 25541977 PMCID: PMC4277459 DOI: 10.1371/journal.pone.0116018] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2014] [Accepted: 12/02/2014] [Indexed: 11/19/2022] Open
Abstract
INTRODUCTION We examined the design, analysis and reporting in multi-reader multi-case (MRMC) research studies using the area under the receiver-operating curve (ROC AUC) as a measure of diagnostic performance. METHODS We performed a systematic literature review from 2005 to 2013 inclusive to identify a minimum 50 studies. Articles of diagnostic test accuracy in humans were identified via their citation of key methodological articles dealing with MRMC ROC AUC. Two researchers in consensus then extracted information from primary articles relating to study characteristics and design, methods for reporting study outcomes, model fitting, model assumptions, presentation of results, and interpretation of findings. Results were summarized and presented with a descriptive analysis. RESULTS Sixty-four full papers were retrieved from 475 identified citations and ultimately 49 articles describing 51 studies were reviewed and extracted. Radiological imaging was the index test in all. Most studies focused on lesion detection vs. characterization and used less than 10 readers. Only 6 (12%) studies trained readers in advance to use the confidence scale used to build the ROC curve. Overall, description of confidence scores, the ROC curve and its analysis was often incomplete. For example, 21 (41%) studies presented no ROC curve and only 3 (6%) described the distribution of confidence scores. Of 30 studies presenting curves, only 4 (13%) presented the data points underlying the curve, thereby allowing assessment of extrapolation. The mean change in AUC was 0.05 (-0.05 to 0.28). Non-significant change in AUC was attributed to underpowering rather than the diagnostic test failing to improve diagnostic accuracy. CONCLUSIONS Data reporting in MRMC studies using ROC AUC as an outcome measure is frequently incomplete, hampering understanding of methods and the reliability of results and study conclusions. Authors using this analysis should be encouraged to provide a full description of their methods and results.
Collapse
Affiliation(s)
| | - Andrew A. Plumb
- Centre for Medical Imaging, University College London, London, United Kingdom
| | - Steve Halligan
- Centre for Medical Imaging, University College London, London, United Kingdom
| | - Thomas R. Fanshawe
- Nuffield Department of Primary Care Health Sciences, Oxford University, Oxford, United Kingdom
| | - Douglas G. Altman
- Centre for Statistics in Medicine, Wolfson College, Oxford University, Oxford, United Kingdom
| | - Susan Mallett
- Nuffield Department of Primary Care Health Sciences, Oxford University, Oxford, United Kingdom
| |
Collapse
|
11
|
Xu J, Zbijewski W, Gang G, Stayman JW, Taguchi K, Lundqvist M, Fredenberg E, Carrino JA, Siewerdsen JH. Cascaded systems analysis of photon counting detectors. Med Phys 2014; 41:101907. [PMID: 25281959 PMCID: PMC4281040 DOI: 10.1118/1.4894733] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2014] [Revised: 07/29/2014] [Accepted: 08/22/2014] [Indexed: 01/02/2023] Open
Abstract
PURPOSE Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). METHODS A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1-7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. RESULTS The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f50 (spatial-frequency at which the MTF falls to a value of 0.50) by ∼30% with corresponding improvement in DQE. The range in exposure and additive noise for which PCDs yield intrinsically higher DQE was quantified, showing performance advantages under conditions of very low-dose, high additive noise, and high fidelity rejection of coincident photons. CONCLUSIONS The model for PCD signal and noise performance agreed with measurements of detector signal, MTF, and NPS and provided a useful basis for understanding complex dependencies in PCD imaging performance and the potential advantages (and disadvantages) in comparison to EIDs as well as an important guide to task-based optimization in developing new PCD imaging systems.
Collapse
Affiliation(s)
- J Xu
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205
| | - W Zbijewski
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205
| | - G Gang
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205
| | - J W Stayman
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205
| | - K Taguchi
- Russell H. Morgan Department of Radiology, Johns Hopkins University, Baltimore, Maryland 21205
| | | | | | - J A Carrino
- Russell H. Morgan Department of Radiology, Johns Hopkins University, Baltimore, Maryland 21205
| | - J H Siewerdsen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205Russell H. Morgan Department of Radiology, Johns Hopkins University, Baltimore, Maryland 21205
| |
Collapse
|
12
|
Abstract
Despite controversy regarding mammography's efficacy, it continues to be the most commonly used breast cancer-screening modality. With the development of digital mammography, some improved benefit has been shown in women with dense breast tissue. However, the density of breast tissue continues to limit the sensitivity of conventional mammography. We discuss the development of some derivative digital technologies, primarily digital breast tomosynthesis, and their strengths, weaknesses, and potential patient impact.
Collapse
Affiliation(s)
- Stephanie K Patterson
- Division of Breast Imaging, Department of Radiology, University of Michigan Health System, Ann Arbor, MI, USA
| | - Marilyn A Roubidoux
- Division of Breast Imaging, Department of Radiology, University of Michigan Health System, Ann Arbor, MI, USA
| |
Collapse
|
13
|
Matsubara K, Matsumoto C, Mochiya Y, Toda K, Noto K, Koshida K. [Radiation dose evaluation in a photon-counting digital mammography unit]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2014; 70:445-52. [PMID: 24858289 DOI: 10.6009/jjrt.2014_jsrt_70.5.445] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The purpose of our study was to evaluate radiation dose and beam quality in photon-counting digital mammography (PCDM) and compare them with those in a full-field digital mammography (FFDM) unit. Dose variation in the X-ray tube axis direction, aluminum half-value layer, average glandular and skin doses, and contrast-to-noise ratio (CNR) were evaluated for the PCDM and FFDM units. In PCDM, the dose variation in the X-ray tube axis direction was greater than that in FFDM. At a tube voltage of 28 kV, the first half-value layers were 0.407 mmAl for PCDM, 0.357 mmAl for FFDM with a molybdenum target and molybdenum filter (Mo/Mo), and 0.579 mmAl for FFDM with a tungsten target and rhodium filter (W/Rh). The average glandular doses with 45-mm-equivalent breast thickness were 0.723 mGy for the PCDM, 1.55 mGy for the FFDM with Mo/Mo in low-dose mode, and 0.835 mGy for the FFDM with W/Rh in low-dose mode. In PCDM, the skin dose was equivalent to or lower than that in FFDM. The CNR was 2.65±0.04, 2.35±0.04, and 2.52±0.03 for the PCDM, FFDM with Mo/Mo, and that with W/Rh, respectively. The CNR for PCDM was significantly higher than that for FFDM (p<0.001). It is therefore possible to reduce the radiation dose to the patient by using a PCDM unit while maintaining a significantly higher CNR than with the FFDM unit.
Collapse
Affiliation(s)
- Kosuke Matsubara
- Department of Quantum Medical Technology, Faculty of Health Sciences, Kanazawa University
| | | | | | | | | | | |
Collapse
|
14
|
Weigel S, Berkemeyer S, Girnus R, Sommer A, Lenzen H, Heindel W. Digital Mammography Screening with Photon-counting Technique: Can a High Diagnostic Performance Be Realized at Low Mean Glandular Dose? Radiology 2014; 271:345-55. [DOI: 10.1148/radiol.13131181] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
15
|
Venturini E, Losio C, Panizza P, Rodighiero MG, Fedele I, Tacchini S, Schiani E, Ravelli S, Cristel G, Panzeri MM, De Cobelli F, Del Maschio A. Tailored Breast Cancer Screening Program with Microdose Mammography, US, and MR Imaging: Short-term Results of a Pilot Study in 40–49-Year-Old Women. Radiology 2013; 268:347-55. [DOI: 10.1148/radiol.13122278] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
16
|
Drukteinis JS, Mooney BP, Flowers CI, Gatenby RA. Beyond mammography: new frontiers in breast cancer screening. Am J Med 2013; 126:472-9. [PMID: 23561631 PMCID: PMC4010151 DOI: 10.1016/j.amjmed.2012.11.025] [Citation(s) in RCA: 114] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2012] [Revised: 11/27/2012] [Accepted: 11/30/2012] [Indexed: 12/16/2022]
Abstract
Breast cancer screening remains a subject of intense and, at times, passionate debate. Mammography has long been the mainstay of breast cancer detection and is the only screening test proven to reduce mortality. Although it remains the gold standard of breast cancer screening, there is increasing awareness of subpopulations of women for whom mammography has reduced sensitivity. Mammography also has undergone increased scrutiny for false positives and excessive biopsies, which increase radiation dose, cost, and patient anxiety. In response to these challenges, new technologies for breast cancer screening have been developed, including low-dose mammography, contrast-enhanced mammography, tomosynthesis, automated whole breast ultrasound, molecular imaging, and magnetic resonance imaging. Here we examine some of the current controversies and promising new technologies that may improve detection of breast cancer both in the general population and in high-risk groups, such as women with dense breasts. We propose that optimal breast cancer screening will ultimately require a personalized approach based on metrics of cancer risk with selective application of specific screening technologies best suited to the individual's age, risk, and breast density.
Collapse
|
17
|
Alemayehu D, Zou KH. Applications of ROC analysis in medical research: recent developments and future directions. Acad Radiol 2012; 19:1457-64. [PMID: 23122565 DOI: 10.1016/j.acra.2012.09.006] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2012] [Revised: 09/17/2012] [Accepted: 09/18/2012] [Indexed: 12/14/2022]
Abstract
With the growing focus on comparative effectiveness research and personalized medicine, receiver-operating characteristic analysis can continue to play an important role in health care decision making. Specific applications of receiver-operating characteristic analysis include predictive model assessment and validation, biomarker diagnostics, responder analysis in patient-reported outcomes, and comparison of alternative treatment options. The authors present a survey of the potential applications of the method and briefly review several relevant extensions. Given the level of attention paid to biomarker validation, personalized medicine and comparative effectiveness research, it is highly likely that the receiver-operating characteristic analysis will remain an important visual and analytic tool for medical research and evidence-based medicine in the foreseeable future.
Collapse
|
18
|
Karellas A. Photon-counting digital mammography: evaluation of performance under clinically relevant conditions. Acad Radiol 2012; 19:913-5. [PMID: 22770464 DOI: 10.1016/j.acra.2012.05.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2012] [Revised: 05/21/2012] [Accepted: 05/21/2012] [Indexed: 10/28/2022]
|