1
|
Li S, Dong Z, Song P, Zou J. A water-immersible scanning mirror with hybrid polymer and elastomer hinges for high-speed and wide-field 3D ultrasound imaging. SENSORS AND ACTUATORS. A, PHYSICAL 2024; 367:115032. [PMID: 39380786 PMCID: PMC11460793 DOI: 10.1016/j.sna.2024.115032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/10/2024]
Abstract
This paper reports a new water-immersible single-axis scanning mirror using hybrid polymer and elastomer hinges to achieve both high scanning resonance frequencies and large tilting angles for high-speed and wide-field 3D ultrasound imaging. To demonstrate the concept, a prototype scanning mirror is designed, fabricated, and characterized. The fast- and slow-scanning were achieved by integrating stiff BoPET (biaxially oriented polyethylene terephthalate) and soft elastomer PDMS (Polydimethylsiloxane) hinges, respectively. The testing results have shown a resonance frequency of 270 Hz for the BoPET hinges and a resonance frequency of 10 Hz for the PDMS hinges when the scanning mirror was immersed in water. 3D ultrasound imaging is demonstrated by combining the fast- and slow-scanning together to provide both an augmented field of view (FoV) and high local imaging volume rate.
Collapse
Affiliation(s)
- Shuangliang Li
- Departement of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Zhijie Dong
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Beckman Institute, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Pengfei Song
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Beckman Institute, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Jun Zou
- Departement of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA
| |
Collapse
|
2
|
Dong Z, Li S, Duan X, Lowerison MR, Huang C, You Q, Chen S, Zou J, Song P. High-Volume-Rate 3-D Ultrasound Imaging Using Fast-Tilting and Redirecting Reflectors. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2023; 70:799-809. [PMID: 37276113 PMCID: PMC10440128 DOI: 10.1109/tuffc.2023.3282949] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Three-dimensional ultrasound imaging has many advantages over 2-D imaging such as more comprehensive tissue evaluation and less operator dependence. However, developing a low-cost and accessible 3-D ultrasound solution with high volume rate and imaging quality remains a challenging task. Recently, we proposed a 3-D ultrasound imaging technique: fast acoustic steering via tilting electromechanical reflectors (FASTER), which uses a fast-tilting acoustic reflector to steer ultrafast plane waves elevationally to achieve high-volume-rate 3-D imaging with conventional 1-D transducers. However, the initial FASTER implementation requires a water tank for acoustic wave conduction and cannot be conveniently used for regular handheld scanning. To address these limitations, here, we developed a novel ultrasound probe clip-on device that encloses a fast-tilting reflector, a redirecting reflector, and an acoustic wave conduction medium. The new FASTER 3-D imaging device can be easily attached to or removed from clinical ultrasound transducers, allowing rapid transformation from 2-D to 3-D imaging. In vitro B-mode studies demonstrated that the proposed method provided comparable imaging quality to conventional, mechanical-translation-based 3-D imaging while offering a much faster volume rate (e.g., 300 versus ∼ 10 Hz). We also demonstrated 3-D power Doppler (PD) and 3-D super-resolution ultrasound localization microscopy (ULM) with the FASTER device. An in vivo imaging study showed that the FASTER device could clearly visualize the 3-D anatomy of the basilic vein. These results suggest that the newly developed redirecting reflector and the clip-on device could overcome key hurdles for future clinical translation of the FASTER 3-D imaging technology.
Collapse
|
3
|
Dong Z, Li S, Duan X, Lowerison MR, Huang C, You Q, Chen S, Zou J, Song P. High Volume Rate 3-D Ultrasound Imaging Using Fast-Tilting and Redirecting Reflectors. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.03.07.531439. [PMID: 36945643 PMCID: PMC10028918 DOI: 10.1101/2023.03.07.531439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/11/2023]
Abstract
3-D ultrasound imaging has many advantages over 2-D imaging such as more comprehensive tissue evaluation and less operator dependence. Although many 3-D ultrasound imaging techniques have been developed in the last several decades, a low-cost and accessible solution with high imaging volume rate and imaging quality remains elusive. Recently we proposed a new, high volume rate 3-D ultrasound imaging technique: Fast Acoustic Steering via Tilting Electromechanical Reflectors (FASTER), which uses a water-immersible and fast-tilting acoustic reflector to steer ultrafast plane waves in the elevational direction to achieve high volume rate 3-D ultrasound imaging with conventional 1-D array transducers. However, the initial implementation of FASTER imaging only involves a single fast-tilting acoustic reflector, which is inconvenient to use because the probe cannot be held in the regular upright position. Also, conventional FASTER imaging can only be performed inside a water tank because of the necessity of using water for acoustic conduction. To address these limitations of conventional FASTER, here we developed a novel ultrasound probe clip-on device that encloses a fast-tilting reflector, a redirecting reflector, and an acoustic wave conduction medium. The new FASTER 3-D imaging device can be easily attached to or removed from clinical ultrasound transducers, allowing rapid transformation from 2-D to 3-D ultrasound imaging. In vitro B-mode imaging studies demonstrated that the proposed method provided comparable imaging quality (e.g., spatial resolution and contrast-to-noise ratio) to conventional, mechanical-translation-based 3-D imaging while providing a much faster 3-D volume rate (e.g., 300 Hz vs ∼10 Hz). In addition to B-mode imaging, we also demonstrated 3-D power Doppler imaging and 3-D super-resolution ultrasound localization microscopy with the newly developed FASTER device. An in vivo imaging study showed that the FASTER device could clearly visualize the 3-D anatomy of the basilic vein of a healthy volunteer, and customized beamforming was implemented to accommodate the speed of sound difference between the acoustic medium and the imaging object (e.g., soft tissue). These results suggest that the newly developed redirecting reflector and the clip-on device could overcome key hurdles for future clinical translation of the FASTER 3-D imaging technology.
Collapse
|
4
|
Target motion management in breast cancer radiation therapy. Radiol Oncol 2021; 55:393-408. [PMID: 34626533 PMCID: PMC8647788 DOI: 10.2478/raon-2021-0040] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Accepted: 08/04/2021] [Indexed: 12/25/2022] Open
Abstract
Background Over the last two decades, breast cancer remains the main cause of cancer deaths in women. To treat this type of cancer, radiation therapy (RT) has proved to be efficient. RT for breast cancer is, however, challenged by intrafractional motion caused by respiration. The problem is more severe for the left-sided breast cancer due to the proximity to the heart as an organ-at-risk. While particle therapy results in superior dose characteristics than conventional RT, due to the physics of particle interactions in the body, particle therapy is more sensitive to target motion. Conclusions This review highlights current and emerging strategies for the management of intrafractional target motion in breast cancer treatment with an emphasis on particle therapy, as a modern RT technique. There are major challenges associated with transferring real-time motion monitoring technologies from photon to particles beams. Surface imaging would be the dominant imaging modality for real-time intrafractional motion monitoring for breast cancer. The magnetic resonance imaging (MRI) guidance and ultra high dose rate (FLASH)-RT seem to be state-of-the-art approaches to deal with 4D RT for breast cancer.
Collapse
|
5
|
Omata D, Munakata L, Kageyama S, Suzuki Y, Maruyama T, Shima T, Chikaarashi T, Kajita N, Masuda K, Tsuchiya N, Maruyama K, Suzuki R. Ultrasound image-guided gene delivery using three-dimensional diagnostic ultrasound and lipid-based microbubbles. J Drug Target 2021; 30:200-207. [PMID: 34254554 DOI: 10.1080/1061186x.2021.1953510] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Gene therapy is a promising technology for genetic and intractable diseases. Drug delivery carriers or systems for genes and nucleic acids have been studied to improve transfection efficiency and achieve sufficient therapeutic effects. Ultrasound (US) and microbubbles have also been combined for use in gene delivery. To establish a clinically effective gene delivery system, exposing the target tissues to US is important. The three-dimensional (3D) diagnostic probe can three-dimensionally scan the tissue with mechanical regulation, and homogenous US exposure to the targeted tissue can be expected. However, the feasibility of therapeutically applying 3D probes has not been evaluated, especially gene delivery. In this study, we evaluated the characteristics of a 3D probe and lipid-based microbubbles (LB) for gene delivery and determined whether the 3D probe in the diagnostic US device could be used for efficient gene delivery to the targeted tissue using a mouse model. The 3D probe RSP6-16 with LB delivered plasmid DNA (pDNA) to the kidney after systemic injection with luciferase activity similar to that of probes used in previously studies. No toxicity was observed after treatment and, therefore, the combined 3D probe and LB would deliver genes to targeted tissue safely and efficiently.
Collapse
Affiliation(s)
- Daiki Omata
- Faculty of Pharma-Science, Laboratory of Drug and Gene Delivery Research, Teikyo University, Tokyo, Japan
| | - Lisa Munakata
- Faculty of Pharma-Science, Laboratory of Drug and Gene Delivery Research, Teikyo University, Tokyo, Japan
| | - Saori Kageyama
- Faculty of Pharma-Science, Laboratory of Drug and Gene Delivery Research, Teikyo University, Tokyo, Japan
| | - Yuno Suzuki
- Faculty of Pharma-Science, Laboratory of Drug and Gene Delivery Research, Teikyo University, Tokyo, Japan
| | - Tamotsu Maruyama
- Faculty of Pharma-Science, Laboratory of Drug and Gene Delivery Research, Teikyo University, Tokyo, Japan
| | - Tadamitsu Shima
- Faculty of Pharma-Science, Laboratory of Drug and Gene Delivery Research, Teikyo University, Tokyo, Japan
| | - Takumi Chikaarashi
- Graduate School of Bio-Applications and Systems Engineering, Tokyo University of Agriculture and Technology, Tokyo, Japan
| | - Naoya Kajita
- Graduate School of Bio-Applications and Systems Engineering, Tokyo University of Agriculture and Technology, Tokyo, Japan
| | - Kohji Masuda
- Graduate School of Bio-Applications and Systems Engineering, Tokyo University of Agriculture and Technology, Tokyo, Japan
| | - Naoto Tsuchiya
- Laboratory of Molecular Carcinogenesis, National Cancer Center Research Institute, Tokyo, Japan
| | - Kazuo Maruyama
- Faculty of Pharma-Science, Laboratory of Theranostics, Teikyo University, Tokyo, Japan.,Advanced Comprehensive Research Organization (ACRO), Teikyo University, Tokyo, Japan
| | - Ryo Suzuki
- Faculty of Pharma-Science, Laboratory of Drug and Gene Delivery Research, Teikyo University, Tokyo, Japan.,Advanced Comprehensive Research Organization (ACRO), Teikyo University, Tokyo, Japan
| |
Collapse
|
6
|
Advances in fetal echocardiography: myocardial deformation analysis, cardiac MRI and three-dimensional printing. Curr Opin Cardiol 2020; 34:35-40. [PMID: 30444761 DOI: 10.1097/hco.0000000000000584] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE OF REVIEW Advances in ultrasound technology have led to new ways of evaluating cardiac function and structure, including myocardial deformation imaging (strain and strain rate), cardiac MRI and three-dimensional (3D) printing. As ultrasound technology has improved, it has become possible to use these modalities to evaluate the fetal heart. This article will review some of the more recent developments in applying these techniques to the evaluation of fetal cardiac structure and function. RECENT FINDINGS Myocardial deformation analyses have led to the establishment of normative values for strain and strain rate in the fetal heart and have also been used to evaluate fetal heart function in both fetal disease states and maternal disease states. Technological advances in MRI technology, 3D imaging and 3D printing have opened up new methods of evaluating fetal structural heart disease. SUMMARY A deeper understanding of the subtleties of myocardial dysfunction in various fetal and maternal disease states may elucidate the pathophysiology involved and lead to new treatment and/or counseling paradigms that may ultimately affect outcome. Similarly, the ability to image the fetal heart in new ways, including fetal MRI and 3D printing, could potentially change fetal counseling techniques and prenatal planning.
Collapse
|
7
|
Sun JX, Cai AL, Xie LM. Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation. World J Clin Cases 2019; 7:2003-2012. [PMID: 31423432 PMCID: PMC6695553 DOI: 10.12998/wjcc.v7.i15.2003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 06/12/2019] [Accepted: 07/03/2019] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Heart defects are the most common congenital malformations in fetuses. Fetal cardiac structure and function abnormalities lead to changes in ventricular volume. As ventricular volume is an important index for evaluating fetal cardiovascular development, an effective and reliable method for measuring fetal ventricular volume and cardiac function is necessary for accurate ultrasonic diagnosis and effective clinical treatment. The new intelligent spatiotemporal image correlation (iSTIC) technology acquires high-resolution volumetric images. In this study, the iSTIC technique was used to measure right ventricular volume and to evaluate right ventricular systolic function to provide a more accurate and convenient evaluation of fetal heart function.
AIM To investigate the value of iSTIC in evaluating right ventricular volume and systolic function in normal fetuses.
METHODS Between October 2014 and September 2015, a total of 123 pregnant women received prenatal ultrasound examinations in our hospital. iSTIC technology was used to acquire the entire fetal cardiac volume with off-line analysis using QLAB software. Cardiac systolic and diastolic phases were defined by opening of the atrioventricular valve and the subsequent closure of the atrioventricular valve. The volumetric data of the two phases were measured by manual tracking and summation of multiple slices and recording of the right ventricular end-systolic volume and the right ventricular end-diastolic volume. The data were used to calculate the right stroke volume, the right cardiac output, and the right ejection fraction. The correlations of changes between the above-mentioned indices and gestational age were analyzed. The right ventricular volumes of 30 randomly selected cases were measured twice by the same sonographer, and the intra-observer agreement measurements were calculated.
RESULTS Among the 123 normal fetuses, the mean right ventricular end-diastolic volume increased from 0.99 ± 0.34 mL at 22 wk gestation to 3.69 ± 0.36 mL at 35+6 wk gestation. The mean right ventricular end-systolic volume increased from 0.43 ± 0.18 mL at 22 wk gestation to 1.36 ± 0.22 mL at 35+6 wk gestation. The mean right stroke volume increased from 0.62 ± 0.29 mL at 22 wk gestation to 2.33 ± 0.18 mL at 35+6 wk gestation. The mean right cardiac output increased from 92.23 ± 40.67 mL/min at 22 wk gestation to 335.83 ± 32.75 mL/min at 35+6 wk gestation. Right ventricular end-diastolic volume, right ventricular end-systolic volume, right stroke volume, and right cardiac output all increased with gestational age and the correlations were linear (P < 0.01). Right ejection fraction had no apparent correlation with gestational age (P > 0.05).
CONCLUSION Fetal right ventricular volume can be quantitatively measured using iSTIC technology with relative ease and high repeatability. iSTIC technology is expected to provide a new method for clinical evaluation of fetal cardiac function.
Collapse
Affiliation(s)
- Jia-Xing Sun
- Ultrasound Department, Shengjing Hospital of China Medical University, Shenyang 110004, Liaoning Province, China
| | - Ai-Lu Cai
- Ultrasound Department, Shengjing Hospital of China Medical University, Shenyang 110004, Liaoning Province, China
| | - Li-Mei Xie
- Ultrasound Department, Shengjing Hospital of China Medical University, Shenyang 110004, Liaoning Province, China
- Ultrasound Department, Roicare Hospital and Clinics, Shenyang 110004, Liaoning Province, China
| |
Collapse
|
8
|
Abstract
With the introduction of the electronic 4-dimensional and spatial-temporal image Correlation (e-STIC), it is now possible to obtain large volume datasets of the fetal heart that are virtually free of artifact. This allows the examiner to use a number of imaging modalities when recording the volumes that include two-dimensional real time, power and color Doppler, and B-flow images. Once the volumes are obtained, manipulation of the volume dataset allows the examiner to recreate views of the fetal heart that enable examination of cardiac anatomy. The value of this technology is that a volume of the fetal heart can be obtained, irrespective of the position of the fetus in utero, and manipulated to render images for interpretation and diagnosis. This article presents a summary of the various imaging techniques and provides clinical examples of its application used for prenatal diagnosis of congenital heart defects and abnormal cardiac function.
Collapse
Affiliation(s)
- Greggory R DeVore
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA.,Fetal Diagnostic Centers, Pasadena, Tarzana, and Lancaster, CA, USA
| | - Gary Satou
- Division of Pediatric Cardiology, Department of Pediatrics, UCLA Mattel Children's Hospital, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
| | - Mark Sklansky
- Division of Pediatric Cardiology, Department of Pediatrics, UCLA Mattel Children's Hospital, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
| |
Collapse
|
9
|
Kaffas AE, Sigrist RMS, Fisher G, Bachawal S, Liau J, Wang H, Karanany A, Durot I, Rosenberg J, Hristov D, Willmann JK. Quantitative Three-Dimensional Dynamic Contrast-Enhanced Ultrasound Imaging: First-In-Human Pilot Study in Patients with Liver Metastases. Theranostics 2017; 7:3745-3758. [PMID: 29109773 PMCID: PMC5667345 DOI: 10.7150/thno.20329] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2017] [Accepted: 07/01/2017] [Indexed: 02/06/2023] Open
Abstract
Purpose: To perform a clinical assessment of quantitative three-dimensional (3D) dynamic contrast-enhanced ultrasound (DCE-US) feasibility and repeatability in patients with liver metastasis, and to evaluate the extent of quantitative perfusion parameter sampling errors in 2D compared to 3D DCE-US imaging. Materials and Methods: Twenty consecutive 3D DCE-US scans of liver metastases were performed in 11 patients (45% women; mean age, 54.5 years; range, 48-60 years; 55% men; mean age, 57.6 years; range, 47-68 years). Pairs of repeated disruption-replenishment and bolus DCE-US images were acquired to determine repeatability of parameters. Disruption-replenishment was carried out by infusing 0.9 mL of microbubbles (Definity; Latheus Medical Imaging) diluted in 35.1 mL of saline over 8 min. Bolus consisted of intravenous injection of 0.2 mL microbubbles. Volumes-of-interest (VOI) and regions-or-interest (ROI) were segmented by two different readers in images to extract 3D and 2D perfusion parameters, respectively. Disruption-replenishment parameters were: relative blood volume (rBV), relative blood flow (rBF). Bolus parameters included: time-to-peak (TP), peak enhancement (PE), area-under-the-curve (AUC), and mean-transit-time (MTT). Results: Clinical feasibility and repeatability of 3D DCE-US using both the destruction-replenishment and bolus technique was demonstrated. The repeatability of 3D measurements between pairs of repeated acquisitions was assessed with the concordance correlation coefficient (CCC), and found to be excellent for all parameters (CCC > 0.80), except for the TP (0.74) and MTT (0.30) parameters. The CCC between readers was found to be excellent (CCC > 0.80) for all parameters except for TP (0.71) and MTT (0.52). There was a large Coefficient of Variation (COV) in intra-tumor measurements for 2D parameters (0.18-0.52). Same-tumor measurements made in 3D were significantly different (P = 0.001) than measurements made in 2D; a percent difference of up to 86% was observed between measurements made in 2D compared to 3D in the same tumor. Conclusions: 3D DCE-US imaging of liver metastases with a matrix array transducer is feasible and repeatable in the clinic. Results support 3D instead of 2D DCE US imaging to minimize sampling errors due to tumor heterogeneity.
Collapse
|
10
|
A Review on Real-Time 3D Ultrasound Imaging Technology. BIOMED RESEARCH INTERNATIONAL 2017; 2017:6027029. [PMID: 28459067 PMCID: PMC5385255 DOI: 10.1155/2017/6027029] [Citation(s) in RCA: 116] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/09/2016] [Accepted: 03/07/2017] [Indexed: 01/06/2023]
Abstract
Real-time three-dimensional (3D) ultrasound (US) has attracted much more attention in medical researches because it provides interactive feedback to help clinicians acquire high-quality images as well as timely spatial information of the scanned area and hence is necessary in intraoperative ultrasound examinations. Plenty of publications have been declared to complete the real-time or near real-time visualization of 3D ultrasound using volumetric probes or the routinely used two-dimensional (2D) probes. So far, a review on how to design an interactive system with appropriate processing algorithms remains missing, resulting in the lack of systematic understanding of the relevant technology. In this article, previous and the latest work on designing a real-time or near real-time 3D ultrasound imaging system are reviewed. Specifically, the data acquisition techniques, reconstruction algorithms, volume rendering methods, and clinical applications are presented. Moreover, the advantages and disadvantages of state-of-the-art approaches are discussed in detail.
Collapse
|
11
|
Advances in 3D echocardiography: From foetus to printing. Arch Cardiovasc Dis 2016; 109:84-6. [DOI: 10.1016/j.acvd.2015.09.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2015] [Accepted: 09/15/2015] [Indexed: 11/17/2022]
|
12
|
Feasibility of three-dimensional reconstruction and automated measurement of fetal long bones using 5D Long Bone. Obstet Gynecol Sci 2015. [PMID: 26217596 PMCID: PMC4515475 DOI: 10.5468/ogs.2015.58.4.268] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Objective To evaluate the feasibility of five-dimensional Long Bone (5D LB), a new technique that automatically archives, reconstructs images, and measures lengths of fetal long bones, to assess whether the direction of volume sweep influences fetal long bone measurements in three-dimensional (3D) ultrasound and 5D LB, and to compare measurements of fetal long bone lengths obtained with 5D LB and those obtained with conventional two-dimensional (2D) and manual 3D techniques. Methods This prospective study included 39 singleton pregnancies at 26+0 to 32+0 weeks of gestation. Multiple pregnancies, fetuses with multiple congenital anomalies, and mothers with underlying medical diseases were excluded. Fetal long bones of the lower extremities-the femur, tibia, and fibula were measured by 2D and 3D ultrasound, and 5D LB, by an expert and non-expert examiner. First, we analyzed the 3D ultrasound and 5D LB data according to 2 different sweeping angles. We analyzed intra- and inter-observer variability and agreement between ultrasound techniques. Paired t-test, interclass correlation coefficient, and Bland-Altman plot and Passing-Bablok regression were used for statistical analysis. Results There was no statistical difference between long bone measurements analyzed according to 2 different volume-sweeping angles by 3D ultrasound and 5D LB. Intra- and inter-observer variability were not significantly different among all 3 ultrasound techniques. Comparing 2D ultrasound and 5D LB, the interclass correlation coefficient for femur, tibia, and fibula was 0.91, 0.92, and 0.89, respectively. Conclusion 5D LB is reproducible and comparable with conventional 2D and 3D ultrasound techniques for fetal long bone measurement.
Collapse
|