1
|
Marrazzo L, Chilà D, Vanore I, Pellegrini R, Voet P, Di Cataldo V, Meattini I, Zani M, Arilli C, Calusi S, Casati M, Compagnucci A, Talamonti C, Livi L, Pallotta S. Planning Automation for Treatment Techniques Comparison and Robustness Analysis: Tangential Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy for Whole Breast Irradiation. Adv Radiat Oncol 2025; 10:101719. [PMID: 40092157 PMCID: PMC11910076 DOI: 10.1016/j.adro.2025.101719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2024] [Accepted: 01/03/2025] [Indexed: 03/19/2025] Open
Abstract
Purpose This study evaluates the use of the mCycle automated planning system integrated into the Monaco Treatment Planning System for step-and-shoot intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) in whole breast irradiation (WBI). The aim was to assess whether automation can standardize plan quality across a diverse patient cohort and compare dosimetric outcomes and robustness of the 2 techniques against setup errors and anatomical variations. Methods and Materials A total of 65 patients with breast cancer who underwent postoperative WBI were selected for the study. Treatment plans were generated using mCycle, which employs multicriteria optimization with no manual intervention. Two automated planning techniques-IMRT and VMAT-were implemented and evaluated based on dosimetric outcomes, physician review, planning time, and plan robustness. The plan deliverability was verified through γ index and point dose measurements. Results The mCycle system produced clinically acceptable plans for both IMRT and VMAT across all patient cohorts. VMAT showed superior target coverage (V95% = 97.9%) and better sparing of ipsilateral organs at risks (OARs), whereas IMRT demonstrated enhanced sparing of contralateral OARs and greater robustness to anatomical changes such as breast swelling. Planning times were reduced with VMAT because of complete automation. Plan deliverability was confirmed with high γ passing rates and acceptable point dose deviations. Conclusions The use of mCycle in WBI planning successfully standardized plan quality and improved workflow efficiency. VMAT provided superior target coverage and ipsilateral OAR sparing but was more sensitive to anatomical changes. IMRT showed better contralateral OAR sparing and robustness. Both techniques are viable, with advantages depending on clinical scenarios.
Collapse
Affiliation(s)
- Livia Marrazzo
- Department of Experimental and Clinical Biomedical Sciences "Mario Serio", University of Florence, Italy
- Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Deborah Chilà
- Department of Experimental and Clinical Biomedical Sciences "Mario Serio", University of Florence, Italy
| | - Immacolata Vanore
- Department of Experimental and Clinical Biomedical Sciences "Mario Serio", University of Florence, Italy
| | - Roberto Pellegrini
- Elekta AB, Medical Affairs & Research Clinical Liaison, Stockholm, Sweden
| | - Peter Voet
- Elekta AB, Clinical Application Development, Stockholm, Sweden
| | - Vanessa Di Cataldo
- Radiation Oncology Unit, Oncology Department, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Icro Meattini
- Department of Experimental and Clinical Biomedical Sciences "Mario Serio", University of Florence, Italy
- Radiation Oncology Unit, Oncology Department, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Margherita Zani
- Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Chiara Arilli
- Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Silvia Calusi
- Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Marta Casati
- Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | | | - Cinzia Talamonti
- Department of Experimental and Clinical Biomedical Sciences "Mario Serio", University of Florence, Italy
- Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Lorenzo Livi
- Department of Experimental and Clinical Biomedical Sciences "Mario Serio", University of Florence, Italy
- Radiation Oncology Unit, Oncology Department, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Stefania Pallotta
- Department of Experimental and Clinical Biomedical Sciences "Mario Serio", University of Florence, Italy
- Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| |
Collapse
|
2
|
Mishra A, Yadav N, Sharma M, Mittal KK, Mishra SP, Verma TR, Tiwari S. Dosimetric Evaluation of Three-dimensional Conformal Radiotherapy, RapidArc, and Hybrid RapidArc Radiotherapy Techniques for Left-sided Breast Cancer. J Med Phys 2025; 50:93-99. [PMID: 40256194 PMCID: PMC12005665 DOI: 10.4103/jmp.jmp_108_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2024] [Revised: 12/10/2024] [Accepted: 12/12/2024] [Indexed: 04/22/2025] Open
Abstract
OBJECTIVE This study aimed to assess the irradiation techniques-three-dimensional conformal radiotherapy (3DCRT), RapidArc (RArc), and hybrid RapidArc (h-RArc)-for left-sided breast cancer patients, focusing on dose distribution in the planning target volume (PTV) and organs at risks (OARs). MATERIALS AND METHODS This study enrolled 20 patients diagnosed with early-stage left-sided breast cancer. All patients received a prescribed dose of 40.05 Gy in 15 fractions (2.67 Gy per fraction), optimized to achieve 95% dose coverage to 95% of the PTV. The dosimetric variations across the three treatment plans for the 20 patients were examined using a one-way ANOVA test. P <0.05 was regarded as statistically significant. RESULTS In the 3DRCT plan, D95% of the PTV was 37.21 ± 0.51 Gy. This value was significantly increased to 39.43 ± 0.27 Gy in the RArc plan (P = 0.001) and to 38.47 ± 0.19 Gy in the h-RArc plan (P = 0.630). The RArc plans demonstrated a superior homogeneity index of 0.12 ± 0.02 compared to both 3DCRT (0.18 ± 0.02) and h-RArc (0.13 ± 0.02). When comparing the increase in monitor units (MUs), h-RArc showed a 62.82% increase over 3D-CRT, whereas demonstrating a 38.05% decrease compared to RArc (P = 0.000). CONCLUSIONS h-RArc treatment plans for breast cancer may be recommended due to their superior and consistent PTV dose coverage and sparing of OARs, in comparison to both 3DRCT and RArc plans. These h-RArc plans are characterized by reduced MU and beam on time, as well as a less low volume dose when compared to RArc plans.
Collapse
Affiliation(s)
- Atul Mishra
- Department of Radiation Oncology, Uttar Pradesh University of Medical Sciences, Saifai, Etawah, Uttar Pradesh, India
| | - Neha Yadav
- Department of Radiation Oncology, Apollomedics Super Speciality Hospitals, Lucknow, Uttar Pradesh, India
| | - Madhu Sharma
- Department of Radiodiagnosis, Axis Imaging Centre, Agra, Uttar Pradesh, India
| | - Kailash Kumar Mittal
- Department of Radiation Oncology, Uttar Pradesh University of Medical Sciences, Saifai, Etawah, Uttar Pradesh, India
| | - Surendra Prasad Mishra
- Department of Radiation Oncology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - Teerth Raj Verma
- Department of Radiotherapy, King George Medical University, Lucknow, Uttar Pradesh, India
| | - Shilpa Tiwari
- Department of Physics, Madhyanchal Professional University, Bhopal, Madhya Pradesh, India
| |
Collapse
|