Hong SJ, Hong MK. Drug-eluting stents for the treatment of coronary artery disease: A review of recent advances. Expert Opin Drug Deliv 2022; 19:269-280. [PMID: 35180832 DOI: 10.1080/17425247.2022.2044784] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Percutaneous coronary intervention is a widely used procedure for the treatment of coronary artery disease to relieve narrowing or occlusion and improve blood supply. Although only balloon angioplasty was performed in the early period, coronary stents were developed later and coronary drug-eluting stents were introduced to decrease in-stent restenosis, which is related to the proliferation and migration of vascular smooth muscle cells. AREAS COVERED The drug-eluting stents are composed of a metallic or polymeric platform, specific drug, and polymers or coating for drug release. In this article, the recent advances in drug-eluting stent technologies for the treatment of coronary artery disease and adjunctive antiplatelet therapy after drug-eluting stent implantation will be reviewed. EXPERT OPINION The need for further advances in drug-eluting stents or fully bioresorbable coronary scaffolds still exists to improve patient survival or clinical outcomes. The use for different actions or of combinations of drugs with several actions can be potential. Technological refinement and progress in manufacturing to improve mechanical integrity are needed, particularly for fully bioresorbable scaffolds. For antiplatelet therapy after stenting, clinical bleeding reduction strategies, such as a shortened duration of dual-antiplatelet therapy, are in progress.
Collapse
Affiliation(s)
- Sung-Jin Hong
- Division of Cardiology, Severance Hospital, Yonsei University College of Medicine, Korea
| | - Myeong-Ki Hong
- Division of Cardiology, Severance Hospital, Yonsei University College of Medicine, Korea
| |
Collapse
|
3
|
Chichareon P, Katagiri Y, Asano T, Takahashi K, Kogame N, Modolo R, Tenekecioglu E, Chang CC, Tomaniak M, Kukreja N, Wykrzykowska JJ, Piek JJ, Serruys PW, Onuma Y. Mechanical properties and performances of contemporary drug-eluting stent: focus on the metallic backbone. Expert Rev Med Devices 2019; 16:211-228. [DOI: 10.1080/17434440.2019.1573142] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Ply Chichareon
- Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
- Division of Cardiovascular Medicine, Department of Internal Medicine, Faculty of Medicine, Prince of Songkla University, Hatyai, Songkhla, Thailand
| | - Yuki Katagiri
- Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | - Taku Asano
- Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | - Kuniaki Takahashi
- Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | - Norihiro Kogame
- Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | - Rodrigo Modolo
- Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
- Department of Internal Medicine, Cardiology Division, University of Campinas (UNICAMP). Campinas, Sao Paulo, Brazil
| | | | - Chun-Chin Chang
- ThoraxCenter, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Mariusz Tomaniak
- ThoraxCenter, Erasmus Medical Center, Rotterdam, the Netherlands
- First Department of Cardiology, Medical University of Warsaw, Warsaw, Poland
| | - Neville Kukreja
- Department of Cardiology, East and North Hertfordshire NHS Trust, Hertfordshire, UK
| | | | - Jan J. Piek
- Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | - Patrick W. Serruys
- International Centre for Circulatory Health, NHLI, Imperial College London, London, UK
| | - Yoshinobu Onuma
- ThoraxCenter, Erasmus Medical Center, Rotterdam, the Netherlands
| |
Collapse
|
4
|
Understanding the Impact of Stent and Scaffold Material and Strut Design on Coronary Artery Thrombosis from the Basic and Clinical Points of View. Bioengineering (Basel) 2018; 5:bioengineering5030071. [PMID: 30181463 PMCID: PMC6164756 DOI: 10.3390/bioengineering5030071] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 08/23/2018] [Accepted: 08/30/2018] [Indexed: 01/09/2023] Open
Abstract
The technology of percutaneous coronary intervention (PCI) is constantly being refined in order to overcome the shortcomings of present day technologies. Even though current generation metallic drug-eluting stents (DES) perform very well in the short-term, concerns still exist about their long-term efficacy. Late clinical complications including late stent thrombosis (ST), restenosis, and neoatherosclerosis still exist and many of these events may be attributed to either the metallic platform and/or the drug and polymer left behind in the arterial wall. To overcome this limitation, the concept of totally bioresorbable vascular scaffolds (BRS) was invented with the idea that by eliminating long-term exposure of the vessel wall to the metal backbone, drug, and polymer, late outcomes would improve. The Absorb-bioabsorbable vascular scaffold (Absorb-BVS) represented the most advanced attempt to make such a device, with thicker struts, greater vessel surface area coverage and less radial force versus contemporary DES. Unfortunately, almost one year after its initial approval by the U.S. Food and Drug Administration, this scaffold was withdrawn from the market due to declining devise utilization driven by the concerns about scaffold thrombosis (ScT) seen in both early and late time points. Additionally, the specific causes of ScT have not yet been fully elucidated. In this review, we discuss the platform, vascular response, and clinical data of past and current metallic coronary stents with the Absorb-BVS and newer generation BRS, concentrating on their material/design and the mechanisms of thrombotic complications from the pre-clinical, pathologic, and clinical viewpoints.
Collapse
|