Alenazi A, Alshibani A. Confirmatory methods for endotracheal tube placement in out-of-hospital settings: A systematic review of the literature.
Heliyon 2024;
10:e28479. [PMID:
38586363 PMCID:
PMC10998048 DOI:
10.1016/j.heliyon.2024.e28479]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Accepted: 03/19/2024] [Indexed: 04/09/2024] Open
Abstract
Background
Confirming proper placement of an endotracheal tube (ETT) is important, as accidental misplacements may occur and lead to critical injuries, potentially leading to adverse outcomes. Multiple methods are available for determining the correct ETT placement in prehospital care.
Objective
To assess the accuracy and reliability of the different methods used to confirm endotracheal intubation in prehospital settings.
Methods
A comprehensive literature search was performed in the MEDLINE, EMBASE, Scopus, and Web of Science databases for studies that were published between 1-June-1992 and 12-June-2022 using a combination of predetermined search terms. Studies that met the inclusion criteria were included and assessed for risk of bias using "Risk of Bias in Non-randomized Studies of Intervention" tool.
Results
Of the 1016 identified studies, nine met the inclusion criteria. Capnography and point-of-care ultrasound showed high sensitivity and specificity rates when applied to confirm ETT placement in prehospital care. Other methods including capnometry, colorimetric detectors, ODDs, and auscultation showed varied sensitivity and specificity. Patient comorbidities and device failure contributed to decreased accuracy rates in prehospital care. Capnography was less reliable in distinguishing between endotracheal intubation and right main stem intubation, which is known as a complication in out-of-hospital endotracheal intubation. Point-of-care ultrasound was more accurate and reliable in detecting oesophageal and endobronchial misplacements. ETCO2 monitors, i.e., capnometry and colorimetric detectors, were less reliable in patients with low perfusion states.
Conclusion
This systematic review showed that there is no single method with 100% accuracy in confirming the correct ETT placement and detecting the occurrence of accidental oesophageal or endobronchial misplacements in prehospital care. Further studies with a larger sample size are needed to assess the accuracy of multiple confirmatory methods in prehospital settings.
Collapse