1
|
Women's expectations, preferences and needs in midwifery care - results from the qualitative Midwifery Care (MiCa) study: Childbirth and early parenthood. Midwifery 2024; 132:103990. [PMID: 38604068 DOI: 10.1016/j.midw.2024.103990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 03/26/2024] [Accepted: 04/02/2024] [Indexed: 04/13/2024]
Abstract
OBJECTIVE The main goals of our study were (I) the investigation of expectations and preferences as well as (II) the determination of needs of women in regard to midwifery care. DESIGN Descriptive phenomenology was used to investigate the ways in which women experienced childbirth and early parenthood. A descriptive qualitative research design was chosen, using focus groups. SETTING ix online focus groups were carried out with 19 women for this part of the Midwifery Care (MiCa) study, mainly from the north of Germany. PARTICIPANTS Women shortly after birth, in puerperium and the first year after childbirth were recruited in Germany. A purposeful strategy according to maximum variation sampling was applied to reach diversity in the sample regarding age and previous children. Data were analysed using qualitative content analysis, according to Mayring, with support of the qualitative data analysis software MAXQDA 2022. FINDINGS Six main categories were derived for both childbirth and early parenthood: (a) involvement of family, (b) need for information, (c) physical and psychological aspects and (d) orientation in the healthcare system. In each group, one main category about provision of healthcare was developed: (e) care around childbirth and (f) midwifery care in early parenthood. Women attached great importance to the communication with midwives and favoured the involvement of their partners in the childbirth process and during parenting. Based on different experiences and inconsistency of information, women would prefer consistency in staff and communication as well as standardised information. CONCLUSIONS From the user's perspective, midwifery care is crucial during childbirth and the child's first year of life. Current health care during and after childbirth and early parenthood lacks individualised care models, emotional support, adequate and professional communication between different health care providers, and consistency in midwifery care. Our findings should be translated into health care delivery with effective interprofessional teamwork within the continuity of midwifery care. Further quantitative research should analyse the individual healthcare situations of women in the reproductive phase of their life as well as of the applied healthcare models in order to personalise care and to improve healthcare quality.
Collapse
|
2
|
Assisted vaginal birth in 21st century: current practice and new innovations. Am J Obstet Gynecol 2024; 230:S917-S931. [PMID: 38462263 DOI: 10.1016/j.ajog.2022.12.305] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Revised: 12/12/2022] [Accepted: 12/14/2022] [Indexed: 03/12/2024]
Abstract
Assisted vaginal birth rates are falling globally with rising cesarean delivery rates. Cesarean delivery is not without consequence, particularly when carried out in the second stage of labor. Cesarean delivery in the second stage is not entirely protective against pelvic floor morbidity and can lead to serious complications in a subsequent pregnancy. It should be acknowledged that the likelihood of morbidity for mother and baby associated with cesarean delivery increases with advancing labor and is greater than spontaneous vaginal birth, irrespective of the method of operative birth in the second stage of labor. In this article, we argue that assisted vaginal birth is a skilled and safe option that should always be considered and be available as an option for women who need assistance in the second stage of labor. Selecting the most appropriate mode of birth at full dilatation requires accurate clinical assessment, supported decision-making, and personalized care with consideration for the woman's preferences. Achieving vaginal birth with the primary instrument is more likely with forceps than with vacuum extraction (risk ratio, 0.58; 95% confidence interval, 0.39-0.88). Midcavity forceps are associated with a greater incidence of obstetric anal sphincter injury (odds ratio, 1.83; 95% confidence interval, 1.32-2.55) but no difference in neonatal Apgar score or umbilical artery pH. The risk for adverse outcomes is minimized when the procedure is conducted by a skilled accoucheur who selects the most appropriate instrument likely to achieve vaginal birth with the primary instrument. Anticipation of potential complications and dynamic decision-making are just as important as the technique for safe instrument use. Good communication with the woman and the birthing partner is vital and there are various recommendations on how to achieve this. There have been recent developments (such as OdonAssist) in device innovation, training, and strategies for implementation at a scale that can provide opportunities for both improved outcomes and reinvigoration of an essential skill that can save mothers' and babies' lives across the world.
Collapse
|
3
|
The OdonAssist inflatable device for assisted vaginal birth-the ASSIST II study (United Kingdom). Am J Obstet Gynecol 2024; 230:S932-S946.e3. [PMID: 38462264 DOI: 10.1016/j.ajog.2023.05.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 05/17/2023] [Accepted: 05/17/2023] [Indexed: 03/12/2024]
Abstract
BACKGROUND Decreasing rates of assisted vaginal birth have been paralleled with increasing rates of cesarean deliveries over the last 40 years. The OdonAssist is a novel device for assisted vaginal birth. Iterative changes to clinical parameters, device design, and technique have been made to improve device efficacy and usability. OBJECTIVE This study aimed to determine if the feasibility, safety, and efficacy of the OdonAssist device were sufficient to justify conducting a future randomized controlled trial. STUDY DESIGN An open-label nonrandomized study of 104 participants having a clinically indicated assisted vaginal birth using the OdonAssist was undertaken at Southmead Hospital, Bristol, United Kingdom. Data were also collected from participants who consented to participate in the study but for whom trained OdonAssist operators were not available, providing a nested cohort. The primary clinical outcome was the proportion of births successfully expedited with the OdonAssist. Secondary outcomes included clinical, patient-reported, operator-reported, device and health care utilization. Neonatal outcome data were reviewed at day 28, and maternal outcomes were investigated up to day 90. Given that the number of successful OdonAssist births was ≥61 out of 104, the hypothesis of a poor rate of 50% was rejected in favor of a good rate of ≥65%. RESULTS Between August 2019 and June 2021, 941 (64%) of the 1471 approached, eligible participants consented to participate. Of these, 104 received the OdonAssist intervention. Birth was assisted in all cephalic vertex fetal positions, at all stations ≥1 cm below the ischial spines (with or without regional analgesia). The OdonAssist was effective in 69 of the 104 (66%) cases, consistent with the hypothesis of a good efficacy rate. There were no serious device-related maternal or neonatal adverse reactions, and there were no serious adverse device effects. Only 4% of neonatal soft tissue bruising in the successful OdonAssist group was considered device-related, as opposed to 20% and 23% in the unsuccessful OdonAssist group and the nested cohort, respectively. Participants reported high birth perception scores. All practitioners found the device use to be straightforward. CONCLUSION Recruitment to an interventional study of a new device for assisted vaginal birth is feasible; 64% of eligible participants were willing to participate. The success rate of the OdonAssist was comparable to that of the Kiwi OmniCup when introduced in the same unit in 2002, meeting the threshold for a randomized controlled trial to compare the OdonAssist with current standard practice. There were no disadvantages of study participation in terms of maternal and neonatal outcomes. There were potential advantages of using the OdonAssist, particularly reduced neonatal soft tissue injury. The same application technique is used for all fetal positions, with all operators deeming the device straightforward to use. This study provides important data to inform future study design.
Collapse
|
4
|
Safety and efficacy of the OdonAssist inflatable device for assisted vaginal birth: the BESANCON ASSIST study. Am J Obstet Gynecol 2024; 230:S947-S958. [PMID: 38462265 DOI: 10.1016/j.ajog.2023.05.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 05/11/2023] [Accepted: 05/17/2023] [Indexed: 03/12/2024]
Abstract
BACKGROUND The first feasibility study of the OdonAssist inflatable device for use in clinically indicated assisted vaginal birth reported a success rate of 48% with no significant safety concerns. Additional studies exploring the device performance in other clinical settings are warranted before definitive conclusions can be drawn about its safety and efficacy in current practice. OBJECTIVE This study aimed to investigate the safety and efficacy of the OdonAssist before conducting a randomized controlled trial. STUDY DESIGN This was an open-label, nonrandomized study of 104 women with a clinically indicated assisted vaginal birth using the OdonAssist at the Besancon University Hospital, France. Data, including those of a nested cohort group of women who had an assisted vaginal birth using vacuum or spatulas because a trained OdonAssist device operator was not available at the time of delivery, were collected. The primary outcome measure was the proportion of successful assisted vaginal births using the OdonAssist. Neonatal outcome data were reviewed at days 1 and 28, and maternal outcomes were investigated up to day 90. RESULTS Between December 2019 and May 2021, 2191 pregnant women were approached, and 83% (1636/1973) of them consented to participate in the study. Among them, 10.7% (176/1636) required an assisted vaginal birth owing to a vertex presentation at +1 and below. The OdonAssist was used in 59% of births (104/176), and 41.1% (72/176) of the participants were included in the nested cohort group. The rate of successful assisted vaginal births using the OdonAssist was 88.5% (92/104). No emergency cesarean deliveries were performed in the OdonAssist group. There were no serious adverse maternal or neonatal reactions related to the use of the device. The rate of third- and fourth-degree perineal tears with the OdonAssist was 3.8% (4/104). The maternal perception ratings of the birth experience with the OdonAssist (collected on days 1, 7, and 28 using a 15-point scale) were high. In addition, the operators reported a positive perception of the device, with ease of use across the different steps of the procedure. One single technique was used for all vertex fetal head positions. CONCLUSION The OdonAssist is a safe and effective alternative to other current devices for assisted vaginal births. The high acceptance rate (83%) among pregnant women and the high rate of successful assisted vaginal births using the OdonAssist confirm the feasibility of a future randomized controlled trial.
Collapse
|
5
|
Women's needs and expectations in midwifery care - Results from the qualitative MiCa (midwifery care) study. Part 1: Preconception and pregnancy. Heliyon 2024; 10:e25862. [PMID: 38370205 PMCID: PMC10867638 DOI: 10.1016/j.heliyon.2024.e25862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 02/04/2024] [Accepted: 02/05/2024] [Indexed: 02/20/2024] Open
Abstract
Midwifery services play an important role in healthcare provision, birth preparation and prevention. Knowledge on women's expectations, preferences and needs regarding midwifery care is crucial not only for clinical care during preconception and pregnancy and research, but also for educational purposes. This descriptive qualitative study aimed to investigate the expectations, preferences and the needs of women concerning midwifery care in Germany. Experienced researcher team conducted interviews with women who have the desire to get pregnant and online focus groups with women in early and late pregnancy. A purposeful recruitment strategy with maximum variation sampling was applied to reach diversity in the sample regarding age, previous children and socioeconomic background. A total of 26 women participated. In the qualitative content analysis according to Mayring, seven main categories were developed for both preconceptional phase and pregnancy: (a) care by midwife, (b) care by obstetrician, (c) involvement of family, (d) need for information, (e) physical aspects, (f) psychological aspects and (g) orientation in healthcare system. One additional category referenced (h) organisation and bureaucracy in pregnant women. Women appreciated the personalised experience provided by midwives leading to trust and empowerment. Women's experiences with midwifery care varied. They reported contradictory information they received about services and care options. They valued interprofessional cooperation, continuity of care, structured information and personalised counselling. Midwives play an important role in healthcare provision, birth preparation and prevention. In order to depict the care situation quantitatively, to personalise care and to optimise healthcare models, a tool to assess the quality of healthcare and to evaluate women's needs and benefits of midwifery care will be developed based on the findings of this study. From the public health perspective, deficits in the German healthcare system concerning insufficient intra-sectoral communication, time pressure and low remuneration should be resolved in further research steps and policy action.
Collapse
|
6
|
Delivery Methods in Twin Gestations: Evaluating Outcomes, Risk Factors, and the Paradigm Shift Towards Elective Cesarean Deliveries. Cureus 2023; 15:e46514. [PMID: 37927678 PMCID: PMC10625172 DOI: 10.7759/cureus.46514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2023] [Accepted: 10/05/2023] [Indexed: 11/07/2023] Open
Abstract
During the past decade, there has been a consistent rise in the number of twin births and the number of overall cesarean sections (CS) worldwide. This is owed to a variety of social, economic, educational, and scientific factors. More women are opting to advance their professional careers and gain financial stability before having children. Although this approach is understandable, a new set of challenges are faced as a result, the most important of which has been infertility due to advanced maternal age and the subsequent use of assisted fertility treatments, which have been noted to cause multiple gestations. Twin gestations are considered high-risk pregnancies and are associated with an amplitude of potential complications. Arguably, the biggest decision an obstetrician must make when dealing with this population is choosing the most appropriate mode of delivery. Given the lack of clear guidance pertaining to twin deliveries, CSs may often be perceived as safer and are often preferred over vaginal deliveries (VD). In this narrative review, we aimed to compare the outcomes of different delivery methods (CS versus VD) to investigate whether CS is truly superior to VD. Data were collected from the past two decades and analyzed based on the neonatal and maternal outcomes for each delivery mode. Our results indicate that planned VD is just as safe as CS, if not superior, in most uncomplicated twin pregnancies. Thus, it is best to advise and encourage healthy expecting twin carriers to undergo VD and explore any hesitations or fears they might have. Furthermore, a detailed guideline regarding twin delivery is essential to establish and better navigate twin deliveries, lower the rate of unnecessary CSs, and reduce overall twin gestation morbidity and mortality.
Collapse
|
7
|
Operative vaginal delivery. REVISTA BRASILEIRA DE GINECOLOGIA E OBSTETRÍCIA 2023; 45:422-434. [PMID: 37595600 PMCID: PMC10438968 DOI: 10.1055/s-0043-1772581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/20/2023] Open
|
8
|
"Assisted vaginal birth using the Paily obstetric forceps vs Ventouse - A randomized clinical trial". Eur J Obstet Gynecol Reprod Biol 2023; 280:40-47. [PMID: 36399919 DOI: 10.1016/j.ejogrb.2022.10.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 10/08/2022] [Accepted: 10/30/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Instruments used in assisted vaginal birth have seen little innovation for decades. Due to the risk of trauma and technical difficulty incurred during forceps delivery, instrumental deliveries are on a decline, and the global rate of primary cesarean birth is rising. The novel Paily Obstetric Forceps (POF) features a compact, lighter design with thinner blades, designed to increase operator comfort and minimize maternal and neonatal injuries. We aim to determine the feasibility and safety of POF in achieving vaginal birth compared to a ventouse device with a 50 mm silastic cup. STUDY DESIGN We conducted a single-blinded, parallel arm, randomized clinical trial of the novel POF vs a ventouse device, in patients undergoing indicated assisted vaginal birth, at a tertiary care obstetric unit. We randomized 100 patients to be allocated on a 1:1 ratio to both intervention arms. Primary outcome was the proportion of successful instrumental deliveries. Secondary outcomes were the number of pulls required during traction and any maternal or neonatal adverse events. RESULTS The POF was significantly more successful in achieving vaginal birth than the ventouse device (n = 50/50, 100 % vs n = 42/50, 84 %, p = 0.006). Operators reported requiring significantly fewer pulls during POF traction than ventouse. POF demonstrated a higher risk for maternal trauma (RR = 3.2, 95 % CI = 1.5 to 6.9, NNH = 2.7) but a lower risk for neonatal injury (RR = 0.6, 95 % CI = 0.3 to 1, NNH = 5.7). Maternal and neonatal recovery durations were comparable. There were no incidences of maternal or neonatal mortality. CONCLUSION The POF can be used in indicated assisted vaginal birth with superior success rates and better neonatal outcomes than ventouse. Other obstetric forceps must be standardized to conduct larger superiority trials of forceps designs.
Collapse
|
9
|
Generating the clinical evidence for an innovation in maternal and newborn health: The OdonAssist™ inflatable device for assisted vaginal birth. REVISTA MÉDICA CLÍNICA LAS CONDES 2023. [DOI: 10.1016/j.rmclc.2023.01.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023] Open
|
10
|
Generando evidencia clínica para una innovación en salud materna y neonatal: el dispositivo inflable OdonAssist™ para parto vaginal asistido. REVISTA MÉDICA CLÍNICA LAS CONDES 2023. [DOI: 10.1016/j.rmclc.2023.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023] Open
|
11
|
Novel device for assisted vaginal birth: using integrated qualitative case study methodology to optimise Odon Device use within a feasibility study in a maternity unit in the Southwest of England. BMJ Open 2022; 12:e059115. [PMID: 35926994 PMCID: PMC9358957 DOI: 10.1136/bmjopen-2021-059115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
OBJECTIVE When novel devices are used 'in human' for the first time, their optimal use is uncertain because clinicians only have experience from preclinical studies. This study aimed to investigate factors that might optimise use of the Odon Device for assisted vaginal birth. DESIGN We undertook qualitative case studies within the ASSIST Study, a feasibility study of the Odon Device. Each 'case' was defined as one use of the device and included at least one of the following: observation of the attempted assisted birth, and an interview with the obstetrician, midwife or woman. Data collection and thematic analysis ran iteratively and in parallel. SETTING Tertiary referral National Health Service maternity unit in the Southwest of England. PARTICIPANTS Women requiring a clinically indicated assisted vaginal birth. INTERVENTION The Odon Device, an innovative device for assisted vaginal birth. PRIMARY AND SECONDARY OUTCOME MEASURES Determining the optimal device technique, device design and defining clinical parameters for use. RESULTS Thirty-nine cases involving an attempted Odon-assisted birth were included in this study, of which 19 resulted in a successful birth with the device. Factors that improved use included optimisation of device technique, device design and clinical parameters for use. Technique adaptations included: applying the device during, rather than between, contractions; having a flexible approach to the application angle; and deflating the air cuff sooner than originally proposed. Three design modifications were proposed involving the deflation button and sleeve. Although use of the device was found to be appropriate in all fetal positions, it was considered contraindicated when the fetal station was at the ischial spines. CONCLUSIONS Case study methodology facilitated the acquisition of rapid insights into device function in clinical practice, providing key insights regarding use, design and key clinical parameters for success. This methodology should be considered whenever innovative devices are introduced into clinical practice. TRIAL REGISTRATION NUMBER ISRCTN10203171.
Collapse
|
12
|
Intrapartum ultrasound visualization of the Odon device during operative vaginal delivery. Am J Obstet Gynecol 2022:S0002-9378(22)00309-X. [PMID: 37278992 DOI: 10.1016/j.ajog.2022.04.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 04/12/2022] [Accepted: 04/13/2022] [Indexed: 06/07/2023]
|
13
|
Women's experiences of the Odon Device to assist vaginal birth and participation in intrapartum research: a qualitative study in a maternity unit in the Southwest of England. BMJ Open 2021; 11:e057023. [PMID: 34911726 PMCID: PMC8679107 DOI: 10.1136/bmjopen-2021-057023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVE To investigate women's experiences of having a birth assisted by the Odon Device (an innovative device for assisted vaginal birth) and participation in intrapartum research. DESIGN Qualitative semistructured interviews and observations undertaken in the context of case study work embedded in the ASSIST feasibility study. SETTING A tertiary referral National Health Service (NHS) maternity unit in the Southwest of England, between 8 October 2018 and 26 January 2019. PARTICIPANTS Eight women, four operators and 11 midwives participated with eight observations of the assisted vaginal birth, eight interviews with women in the postnatal period, 39 interviews/reflections with operators and 19 interviews with midwives. Women in the case study research were recruited from participants in the main ASSIST Study. INTERVENTION The Odon Device, an innovative device for assisted vaginal birth. RESULTS Thirty-nine case studies were undertaken. Triangulation of data sources (participant observation, interviews with women, operators and midwives) enabled the exploration of women's experiences of the Odon Device and recruitment in the intrapartum trial. Experiences were overwhelmingly positive. Women were motivated to take part by a wish for a kinder birth, and because they perceived both the recruitment and research processes (including observation) to be highly acceptable, regardless of whether the Odon-assisted birth was successful or not. CONCLUSIONS Interviews and observations from multiple stakeholders enabled insight into women's experiences of an innovative device for assisted vaginal birth. Applying these qualitative methods more broadly may illuminate perspectives of key stakeholders in future intrapartum intervention research and beyond. TRIAL REGISTRATION NUMBER ISRCTN10203171; ASSIST Study registration; https://doi.org/10.1186/ISRCTN10203171.
Collapse
|
14
|
Exploring the reporting standards of RCTs involving invasive procedures for assisted vaginal birth: A systematic review. Eur J Obstet Gynecol Reprod Biol 2021; 262:166-173. [PMID: 34023718 PMCID: PMC8250286 DOI: 10.1016/j.ejogrb.2021.05.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Revised: 04/29/2021] [Accepted: 05/11/2021] [Indexed: 11/21/2022]
Abstract
OBJECTIVE Assisted vaginal birth (AVB) is a complex intervention involving medical devices, comprising multiple components. This complexity creates difficulties when designing and conducting randomised controlled trials (RCTs), in terms of describing, standardising and monitoring the intervention, and accounting for differing clinician expertise. This review examines the reporting standards of complex interventions involving a medical device, in the context of AVB RCTs. STUDY DESIGN Searches were undertaken from the start of indexing to March 2021, and limited to RCTs, feasibility and pilot studies including at least one device for AVB. RCTs were selected if they included participants having an AVB with any device, with or without a comparator group. Reporting details were assessed according to the Consolidating Standards of Reporting Trials extension for non-pharmacological treatments (CONSORT-NPT), focusing on intervention descriptions, standardization, adherence and clinician expertise. Screening of abstracts, full-text articles and data extraction was performed by two independent reviewers. RESULTS Of 4098 abstracts and 83 full-text articles, 39 papers were included, investigating 80 interventions. Twenty-seven different named devices were identified. Intervention descriptions were provided in 20 (55%) papers with varying levels of detail and with only one covering the entire procedure. Standardization of interventions was mentioned in 25 papers (64%). Only eight (21%) papers reported any form of adherence to the intended procedure. Some data regarding expertise were reported in 25 (64%) papers. CONCLUSIONS Despite some compliance with reporting standards, there is a lack of detail regarding intervention description, standardization, adherence and expertise in RCTs of AVB. This creates difficulties in understanding how intervention delivery was intended and what actually occurred. Clearer guidelines for the reporting of invasive procedures and devices are required.
Collapse
|
15
|
The Odon Device™ for assisted vaginal birth: a feasibility study to investigate safety and efficacy-The ASSIST II study. Pilot Feasibility Stud 2021; 7:72. [PMID: 33741082 PMCID: PMC7977305 DOI: 10.1186/s40814-021-00814-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Accepted: 03/08/2021] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND The Odon Device™ is a new device for assisted vaginal birth that employs an air cuff around the fetal head for traction. Assisted vaginal birth (AVB) is a vital health intervention that can result in better outcomes for mothers and their babies when complications arise in the second stage of labour. Unfortunately, instruments for AVB (forceps and ventouse) are often not used in settings where there is most clinical need often due to lack of training and resources, resulting in maternal and neonatal morbidity and mortality which could have been prevented. This is often due to a lack of trained operators as well as difficulties in the sterilisation and maintenance of AVB devices. This novel, single use device has the potential to mitigate these difficulties as it is single use and is potentially simpler to use than forceps and ventouse. All the studies of the Odon Device to date (pre-clinical, preliminary developmental and clinical) suggest that the Odon Device does not present a higher risk to mothers or babies compared to current standard care, and recruitment to intrapartum research exploring the device is feasible and acceptable to women. The first study in which the Odon Device was used in clinically indicated conditions (the ASSIST Study) reported a lower efficacy than those reported with established devices. The reasons need to be explored, specifically focussing on learning curve, the technique of the doctors using this new device and potential modifications to device design. A follow-on clinical study to further investigate the efficacy and safety of the Odon Device in its indicated use, the ASSIST II Study, is therefore being undertaken. METHODS The primary feasibility outcome is study feasibility (recruitment and retention rates) whilst the primary clinical outcome successful vaginal birth completed with the Odon Device. Key secondary feasibility outcomes include participant withdrawal, compliance in data collection and acceptability of the device to women and operators. Secondary clinical outcomes include maternal, neonatal and device outcomes. Safety data will be reviewed following every birth exploring maternal, neonatal and device risks. Using A'Hern approach for sample size calculation, we aim to recruit 104 women requiring an assisted vaginal birth for a recognised clinical indication. Assuming an AVB success rate of 65% or more, a one-sided alpha risk of 5% and power of 90%. DISCUSSION The data from the ASSIST II Study will provide the information required regarding acceptability, recruitment, outcome data collection, device design, technique of device use and operator learning curve in order to design a future randomised controlled trial of the Odon Device versus current modes of assisted vaginal birth. TRIAL REGISTRATION ISRCTN registration: 38829082 (prospectively registered July 26, 2019).
Collapse
|