1
|
Nicolau EG, Reis LO. Ultrasonographic assessment of the uterocervical angle in the second trimester of pregnancy as a predictor of spontaneous preterm birth. Clin Radiol 2025; 84:106853. [PMID: 40056861 DOI: 10.1016/j.crad.2025.106853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2024] [Revised: 12/20/2024] [Accepted: 02/11/2025] [Indexed: 03/10/2025]
Abstract
AIM To evaluate the uterocervical angle in the second trimester in singleton pregnancies as a predictor of spontaneous preterm labour. MATERIAL AND METHODS An observational cohort study was carried out from March 2022 to May 2023, including consecutively selected patients with singleton pregnancies who underwent routine examinations between 18.0 and 23.6 weeks to analyse the risk of prematurity. The uterocervical angle (UCA) measurement was added to the transvaginal ultrasonographic analysis of the cervix. Birth-related outcomes were prospectively collected. RESULTS patients were evaluated. The occurrence of spontaneous preterm birth (sPTB) before 37 weeks was 12%, with 50 patients. An association was observed between a more obtuse uterocervical angle and the occurrence of birth before 37 weeks, with the area under the curve of 0.636 (p=0.003; 95% CI: 0.546-0.726). The cutoff point of 77.2 degrees demonstrated a sensitivity of 80% and specificity of 29.4% (p=0.003), a positive predictive value of 13.6%, and a negative predictive value of 91.3%, with a positive likelihood ratio of 1.13 and negative 0.88. CONCLUSION The measurement of UCA in the second trimester of pregnancy is associated with the occurrence of sPTB. The result corroborates recent literature conclusions that UCA is a relatively recent predictor of sPTB. New evidence in different populations may contribute to its possible incorporation into prematurity risk assessment.
Collapse
Affiliation(s)
- E G Nicolau
- Postgraduate Program in Health Sciences, Pontifical Catholic University of Campinas, PUC-Campinas, Campinas, Sao Paulo, Brazil.
| | - L O Reis
- Postgraduate Program in Health Sciences, Pontifical Catholic University of Campinas, PUC-Campinas, Campinas, Sao Paulo, Brazil; UroScience, University of Campinas, Unicamp, Campinas, São Paulo, Brazil.
| |
Collapse
|
2
|
Meng L, Öberg S, Sandström A, Reilly M. Association between infertility and cervical insufficiency in nulliparous women-the contribution of fertility treatment. Am J Obstet Gynecol 2025; 232:468.e1-468.e9. [PMID: 39477049 DOI: 10.1016/j.ajog.2024.10.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2024] [Revised: 10/21/2024] [Accepted: 10/24/2024] [Indexed: 12/01/2024]
Abstract
BACKGROUND Pregnancies conceived through assisted reproduction have been associated with increased risks of adverse pregnancy and delivery outcomes, including cervical insufficiency (CI). Despite CI being a significant cause of late miscarriage or preterm birth, there are minimal published data on the associations of infertility (with or without fertility treatment) with CI. OBJECTIVE To examine the associations between infertility-assisted reproduction and CI in nulliparous women. STUDY DESIGN This population-based case-control study used data from Swedish national health registers to extract 2662 cases of cervical insufficiency in singleton pregnancies of nulliparous women in the 21-year period (1992-2012). The reference group of 26,620 controls was extracted from the population of non-cases using simple random sampling. RESULTS On adjusting for maternal characteristics and medical history, infertility was associated with CI, overall (adjusted odds ratio [aOR] 1.91 [1.53, 2.39]) and in the subgroup of nonusers of fertility treatment, aOR 1.60 (1.21, 2.12), compared to women without infertility. Among women with infertility, pregnancies conceived with the aid of fertility treatment had higher risk of CI than naturally-conceived pregnancies, aOR 1.49 (1.05, 2.10). In the subgroup of women with infertility and no history of miscarriage, the use of fertility treatment was associated with CI, aOR 3.48 (2.02. 5.98). No association was found between fertility treatment and CI in the pregnancies of women with infertility and a history of miscarriage. CONCLUSION From this study, we conclude that CI in nulliparous women is associated with both infertility and its treatment. For infertile women, the risk of CI following fertility treatment was seen only in those with no history of miscarriage, providing crucial information for improving risk assessment and management strategies for preterm birth prevention in populations availing of fertility treatment.
Collapse
Affiliation(s)
- Lili Meng
- Department of Gynecology and Obstetrics, The Affiliated Guangdong Second Provincial General Hospital of Jinan University, Guangzhou City, China
| | - Sara Öberg
- Department of Medical Epidemiology and Biostatistics, Karolinska Institutet, Stockholm, Sweden; Department of Epidemiology, T.H. Chan School of Public Health, Harvard, Boston, MA
| | - Anna Sandström
- Clinical Epidemiology Division, Department of Medicine, Karolinska Institutet, Stockholm, Sweden; Department of Women's Health, Karolinska University Hospital, Stockholm, Sweden
| | - Marie Reilly
- Department of Medical Epidemiology and Biostatistics, Karolinska Institutet, Stockholm, Sweden.
| |
Collapse
|
3
|
Becerra-Mojica CH, Mora-Guevara E, Parra-Saavedra MA, Martínez-Vega RA, Díaz-Martínez LA, Rincón-Orozco B. Low Levels of Complement Factor H in the First Trimester of Pregnancy Are Associated with Spontaneous Preterm Birth. Int J Mol Sci 2024; 25:10549. [PMID: 39408876 PMCID: PMC11476428 DOI: 10.3390/ijms251910549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2024] [Revised: 09/18/2024] [Accepted: 09/28/2024] [Indexed: 10/20/2024] Open
Abstract
Preterm birth (PTB) remains a significant public health concern, and prediction is an important objective, particularly in the early stages of pregnancy. Many studies have relied on cervical characteristics in the mid-trimester, with limited results. It is therefore crucial to identify novel biomarkers to enhance the ability to identify women at risk. The complement pathway is implicated in the process of placentation, and recent proteomics studies have highlighted the potential roles of some complement proteins in the pathophysiology of PTB. To determine the association between the occurrence of spontaneous preterm birth (sPTB) and the concentration of complement C3, factor B, and factor H in the blood of pregnant women during the first trimester. This prospective cohort study included women with singleton pregnancies, both with and without a history of sPTB, from two health institutions in Bucaramanga, Colombia. The outcome was sPTB before 37 weeks. A blood sample was obtained between 11 + 0 to 13 + 6 weeks. ELISA immunoassay was performed to quantify the levels of C3, factor B, and factor H. A total of 355 patients were analyzed, with a rate of sPTB of 7.6% (27/355). The median plasma concentration for C3, factor B, and factor H were 488.3 μg/mL, 352.6 μg/mL, and 413.2 μg/mL, respectively. The median concentration of factor H was found to be significantly lower in patients who delivered preterm compared to patients who delivered at term (382 μg/mL vs. 415 μg/mL; p = 0.034). This study identified a significant association between low first-trimester levels of factor H and sPTB before 37 weeks. These results provide relevant information about a new possible early biomarker for sPTB. However, the results must be confirmed in different settings, and the predictive value must be examined.
Collapse
Affiliation(s)
- Carlos Hernán Becerra-Mojica
- School of Medicine, Universidad Industrial de Santander, Bucaramanga 680002, Colombia; (E.M.-G.); (L.A.D.-M.)
- Centro de Atención Materno-Fetal INUTERO, Floridablanca 681004, Colombia
| | - Eliana Mora-Guevara
- School of Medicine, Universidad Industrial de Santander, Bucaramanga 680002, Colombia; (E.M.-G.); (L.A.D.-M.)
| | | | | | - Luis Alfonso Díaz-Martínez
- School of Medicine, Universidad Industrial de Santander, Bucaramanga 680002, Colombia; (E.M.-G.); (L.A.D.-M.)
| | - Bladimiro Rincón-Orozco
- School of Medicine, Universidad Industrial de Santander, Bucaramanga 680002, Colombia; (E.M.-G.); (L.A.D.-M.)
| |
Collapse
|
4
|
Romero R, Meyyazhagan A, Hassan SS, Creasy GW, Conde-Agudelo A. Vaginal Progesterone to Prevent Spontaneous Preterm Birth in Women With a Sonographic Short Cervix: The Story of the PREGNANT Trial. Clin Obstet Gynecol 2024; 67:433-457. [PMID: 38576410 PMCID: PMC11047312 DOI: 10.1097/grf.0000000000000867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/06/2024]
Abstract
The PREGNANT trial was a randomized, placebo-controlled, multicenter trial designed to determine the efficacy and safety of vaginal progesterone (VP) to reduce the risk of birth < 33 weeks and of neonatal complications in women with a sonographic short cervix (10 to 20 mm) in the mid-trimester (19 to 23 6/7 wk). Patients allocated to receive VP had a 45% lower rate of preterm birth (8.9% vs 16.1%; relative risk = 0.55; 95% CI: 0.33-0.92). Neonates born to mothers allocated to VP had a 60% reduction in the rate of respiratory distress syndrome. This article reviews the background, design, execution, interpretation, and impact of the PREGNANT Trial.
Collapse
Affiliation(s)
- Roberto Romero
- Pregnancy Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, United States Department of Health and Human Services, Bethesda, Maryland
- Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, Michigan
- Department of Epidemiology and Biostatistics, Michigan State University, East Lansing, Michigan
| | - Arun Meyyazhagan
- Pregnancy Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, United States Department of Health and Human Services, Bethesda, Maryland
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, Michigan
- Centre of Perinatal and Reproductive Medicine, University of Perugia, Perugia, Italy
| | - Sonia S. Hassan
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, Detroit, Michigan
- Office of Women’s Health, Integrative Biosciences Center, Wayne State University, Detroit, Michigan
- Department of Physiology, Wayne State University School of Medicine, Detroit, Michigan
| | - George W. Creasy
- Center for Biomedical Research, Population Council, New York, New York
| | - Agustin Conde-Agudelo
- Oxford Maternal and Perinatal Health Institute, Green Templeton College, University of Oxford, Oxford, UK
| |
Collapse
|
5
|
Hessami K, D'Alberti E, Mascio DD, Berghella V. Universal cervical length screening and risk of spontaneous preterm birth: a systematic review and meta-analysis. Am J Obstet Gynecol MFM 2024; 6:101343. [PMID: 38479489 DOI: 10.1016/j.ajogmf.2024.101343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 02/20/2024] [Accepted: 03/04/2024] [Indexed: 04/06/2024]
Abstract
OBJECTIVE To evaluate the risk of spontaneous preterm birth with or without universal transvaginal ultrasound cervical length screening at the time of midtrimester scan. DATA SOURCES Medline, Embase, ClinicalTrials.gov, and Web of Science were systematically searched from the inception of the databases to November 12, 2023, using combinations of the relevant medical subject heading terms, key words, and word variants that were considered suitable for the topic. STUDY ELIGIBILITY CRITERIA Studies including individuals with singleton gestations at 16-25 weeks of gestation screened or not screened with universal transvaginal ultrasound cervical length screening were considered eligible. Primary outcome was spontaneous preterm birth <37 weeks; secondary outcomes were spontaneous preterm birth <34 and <32 weeks. METHODS Random effect head-to-head analyses were used to directly compare each outcome, expressing the results as summary odds ratio and relative 95% confidence interval. The quality of the included studies was independently assessed by 2 reviewers, using the Newcastle-Ottawa scale for cohort studies and the Cochrane risk-of-bias tool for randomized controlled studies. The study was registered on the prospective register of systematic reviews database (PROSPERO) (registration number: CRD42022385325). RESULTS Eight studies, including 447,864 pregnancies, were included in the meta-analysis (213,064 screened with transvaginal ultrasound cervical length and 234,800 unscreened). In the overall analysis, universal transvaginal ultrasound cervical length did not significantly decrease the spontaneous preterm birth rates <37 weeks (odds ratio, 0.92 [95% confidence interval, 0.84-1.01], P=.07) and <34 weeks (odds ratio, 0.87 [95% confidence interval, 0.73-1.04], P=.12), but was significantly associated with a lower risk of spontaneous preterm birth <32 weeks (odds ratio, 0.84 [95% confidence interval, 0.76-0.94], P=.002). Individuals without a prior spontaneous preterm birth had a significantly lower risk of spontaneous preterm birth <37 weeks (odds ratio, 0.88 [95% confidence interval, 0.79-0.97], P=.01) and a lower trend of spontaneous preterm birth <32 weeks (odds ratio, 0.82 [95% confidence interval, 0.66-1.01], P=.06) when screened with transvaginal ultrasound cervical length, compared with no screening. CONCLUSION Universal transvaginal ultrasound cervical length screening usually <24 weeks in singletons without a prior spontaneous preterm birth, is associated with a significant reduction in spontaneous preterm birth <37 weeks, compared with no screening.
Collapse
Affiliation(s)
- Kamran Hessami
- Maternal Fetal Care Center, Boston Children's Hospital, Harvard Medical School, Boston, MA (Dr Hessami)
| | - Elena D'Alberti
- Department of Maternal and Child Health and Urological Sciences, Sapienza University of Rome, Rome, Italy (Drs D'Alberti and Di Mascio)
| | - Daniele Di Mascio
- Department of Maternal and Child Health and Urological Sciences, Sapienza University of Rome, Rome, Italy (Drs D'Alberti and Di Mascio)
| | - Vincenzo Berghella
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Thomas Jefferson University Hospital, Philadelphia, PA (Dr Berghella).
| |
Collapse
|
6
|
Cheung KW, Au TST, Li J, Seto MTY. First-trimester and early-second-trimester transvaginal cervical length before 16 weeks among women with preterm and term birth: a systematic review and meta-analysis. Am J Obstet Gynecol MFM 2024; 6:101282. [PMID: 38242499 DOI: 10.1016/j.ajogmf.2024.101282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 12/27/2023] [Accepted: 01/03/2024] [Indexed: 01/21/2024]
Abstract
OBJECTIVE This study aimed to evaluate the differences in first-trimester and early-second-trimester transvaginal cervical length between patients with spontaneous preterm birth and those with term birth. DATA SOURCES PubMed, MEDLINE, Embase, and the Cochrane Library were systematically searched through August 2023. STUDY ELIGIBILITY CRITERIA Studies had to include (1) transvaginal cervical length measurement before 16+0 weeks of gestation and (2) transvaginal cervical length measurement in a population of patients who delivered preterm and at term. Abstracts, studies with duplicated data, and those with cervical length measured by transabdominal ultrasound scan were excluded. METHODS K.W.C. and J.L. searched for, screened, and reviewed the articles independently. The quality of the studies was assessed using the Newcastle-Ottawa scale. Mean differences were calculated using a random-effects model and pooled through a meta-analysis. RESULTS A total of 5727 published articles were identified. Only 10 studies (which analyzed 22,151 pregnancies) met the inclusion criteria. All studies excluded iatrogenic preterm birth. Transvaginal cervical length was significantly shorter in women with spontaneous preterm birth than in those who delivered at term (mean difference, -0.97; 95% confidence interval, -1.65 to -0.29; P=.005; I2=69%). When a linear technique was used to measure transvaginal cervical length, a significantly shorter transvaginal cervical length was associated with spontaneous preterm birth as opposed to term birth (mean difference, -1.09; 95% confidence interval, -1.96 to -0.21; P=.02; I2=77%). A shorter transvaginal cervical length measured by other techniques was also associated with spontaneous preterm birth before 34 to 35 weeks (mean difference, -1.87; 95% confidence interval, -3.04 to -0.70; P=.002; I2=0%). When studies where interventions were given for a "short" cervix or studies with a mean transvaginal cervical length ≥40 mm were excluded, a significantly shorter transvaginal cervical length was observed among those with spontaneous preterm birth (mean difference, -1.13; 95% confidence interval, -1.89 to -0.37; P=.004; mean difference, -0.86; 95% confidence interval, -1.67 to -0.04; P=.04; respectively). The optimal transvaginal cervical length cutoff was 38 to 39 mm, yielding pooled sensitivity of 0.80, specificity of 0.45, positive likelihood ratio of 1.16, negative likelihood ratio of 0.33, diagnostic odds ratio of 5.12, and an area under the curve of 0.75. CONCLUSION Women with spontaneous preterm birth had significantly shorter transvaginal cervical length before 16 weeks of gestation compared with those who delivered at term. The linear method and the 2-line method are acceptable techniques for measuring transvaginal cervical length.
Collapse
Affiliation(s)
- Ka Wang Cheung
- Department of Obstetrics and Gynaecology, Queen Mary Hospital, The University of Hong Kong, Hong Kong Special Administrative Region, China.
| | - Tiffany Sin-Tung Au
- Department of Obstetrics and Gynaecology, Queen Mary Hospital, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Justin Li
- Department of Obstetrics and Gynaecology, Queen Mary Hospital, The University of Hong Kong, Hong Kong Special Administrative Region, China
| | - Mimi Tin Yan Seto
- Department of Obstetrics and Gynaecology, Queen Mary Hospital, The University of Hong Kong, Hong Kong Special Administrative Region, China
| |
Collapse
|
7
|
Stratulat V, Melamed N, Barrett J, Ladhani NNN, Anabusi S, Quaglietta P, Hack K, Ronzoni S. Cervical assessment certification and its impact on performance quality in the context of universal cervical screening. Int J Gynaecol Obstet 2024; 164:951-958. [PMID: 37675927 DOI: 10.1002/ijgo.15078] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 08/08/2023] [Accepted: 08/17/2023] [Indexed: 09/08/2023]
Abstract
OBJECTIVE To assess the impact of the introduction of universal transvaginal cervical screening and certification on the quality of cervical length ultrasound images. METHODS The present study included a retrospective cohort of singleton pregnancies that underwent transvaginal cervical length measurement at the anatomical scan (180/7 and 236/7 weeks) before (period A, 2015-2017) and after (period B, 2017-2019) the introduction of universal transvaginal cervical length screening. Independent observers blindly evaluated the images obtained for cervical length using a qualitative scoring method based on five criteria, according to the Fetal Medicine Foundation. RESULTS In all, 6013 patients met the inclusion criteria, 3333 in period A and 2680 in period B. Maternal characteristics and risk factors for preterm birth were similar between the two periods. The acceptance of transvaginal cervical length measurement in period B was 95.5% in the overall cohort and 100% in the subgroup of high-risk patients. The quality score was significantly higher in period B than in period A. Among the image quality criteria, the anterior/posterior ratio, the correct magnification of the images, and the calipers' placement contributed significantly to the improved quality score in period B. Most of the sonographers performed better in period B, irrespective of the years of experience, but certificate holders obtained higher scores than non-certified sonographers, particularly those in mid-career. The identification of short cervix was significantly higher in period B than in period A. CONCLUSION The implementation of universal transvaginal cervical length screening and the certification process are associated with improved quality of cervical length images, even among expert sonographers and in the presence of anatomical pitfalls.
Collapse
Affiliation(s)
- Vasilica Stratulat
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Dan Women & Babies Program, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
- Department of Medical Imaging, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Nir Melamed
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Dan Women & Babies Program, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Jon Barrett
- Department of Obstetric and Gynecology, McMaster University, Hamilton, Ontario, Canada
| | - Noor N N Ladhani
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Dan Women & Babies Program, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Saja Anabusi
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Dan Women & Babies Program, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Paula Quaglietta
- Department of Genetics and Genome Biology, Institute of Medical Science, University of Toronto, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Kalesha Hack
- Department of Medical Imaging, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Stefania Ronzoni
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Dan Women & Babies Program, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|