Lim VY, Buellesfeld L, Gerckens U, Mueller R, Schmidt T, Grube E. Use of Taxus polymer-coated paclitaxel-eluting stents for treatment of in-stent restenosis in real world patients: Results of clinical and angiographic follow-up at six months in a single-center registry.
Catheter Cardiovasc Interv 2006;
68:343-8. [PMID:
16897778 DOI:
10.1002/ccd.20785]
[Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE
To evaluate the safety and efficacy of Taxus paclitaxel-eluting stents in a real world group of unselected patients with coronary in-stent restenosis (ISR) lesions.
METHODS
This is a prospective single-center registry of a consecutive series of 94 patients with 104 ISR lesions, without previous brachytherapy, over a period of 1 year. Quantitative coronary angiographic analyses were performed at baseline and at 6-month angiographic follow-up. Clinical follow-up were obtained at 6 months.
RESULTS
Pre-intervention mean reference vessel diameter was 2.62 +/- 0.50 mm and mean lesion length was 13.95 +/- 6.78 mm. Baseline ISR patterns were mostly either Type I focal (32.7%) or Type II diffuse intrastent (48.1%). At 6-month angiographic follow-up, the in-stent and in-segment binary restenosis was 3.8% (4/105) and 7.6% (8/105) respectively, and the in-stent and in-segment late loss was 0.30 +/- 0.50 mm and 0.57 +/- 0.54 mm, respectively. Seven of these eight restenosed lesions had a diffuse or proliferative ISR pattern prior to intervention. Lesions that restenosed had longer mean stent length per lesion (37.3 mm vs. 22.5 mm in nonrestenosed group; P = 0.001) and more likely to have had a pattern of total occlusion pre-intervention (25.0% vs. 3.1% in nonrestenosed group; P = 0.046). At 6-month clinical follow-up, the MACE rate was 8.5% and target lesion revascularization rate was 7.4%. There was no death but subacute stent thrombosis occurred in 1 patient (1.1%) at 3 days after intervention.
CONCLUSIONS
Paclitaxel-eluting Taxus stent for the treatment of ISR effectively suppresses recurrent neointimal proliferation, and was safe and efficacious at 6-month follow-up.