1
|
Escorial-Moya C, Lobo-Matas I, Calderón-Sandubete E, Medrano-Ortega FJ, Varela-Aguilar JM, Delgado-Cuesta J. High diagnostic yield of ultrasound-guided core needle biopsy of lymphadenopathy performed in an internal medicine department. Rev Clin Esp 2025; 225:502282. [PMID: 40157646 DOI: 10.1016/j.rceng.2025.502282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2024] [Accepted: 11/16/2024] [Indexed: 04/01/2025]
Abstract
BACKGROUND Core needle biopsy (CNB) is often the initial test for polyadenopathic syndrome and is usually performed by radiologists. The objectives of this study are to determine the diagnostic yield of ultrasound-guided CNB of lymph nodes performed by internists at a tertiary care hospital, the most frequent etiological diagnoses, and the safety of this technique. MATERIALS Observational, descriptive study in which we included all patients over 17 years of age who had undergone ultrasound-guided CNB of lymphadenopathy by a member of the internal medicine service of the Virgen del Rocío University Hospital in Seville from 2021 to 2023. RESULTS A total of 76 patients were included, 49 (64.5%) were male and the median age [IQR] was 64 [42-75] years. The most frequent location of lymphadenopathy was inguinal (38.2%). This test allowed a definitive diagnosis in 71 (93.4%) of the patients. Of the 5 in whom the diagnosis was not reached by the CNB, three required an open biopsy, one was diagnosed with Bartonella henselae by serology and in a fifth the diagnosis was not reached. The median delay for the BAG[IQR] was 1[0-3] days. No patient had complications. The most frequent diagnosis was lymphoma in 31 (41.8%) patients. CONCLUSIONS Ultrasound-guided CNB performed by internists is a safe, feasible test with very little delay. These data support the extension of this practice to the rest of the internal medicine services.
Collapse
Affiliation(s)
- C Escorial-Moya
- Servicio de Medicina Interna, Hospital Universitario Virgen del Rocío; Departamento de Medicina, Hospital Universitario Virgen del Rocío, Facultad de Medicina, Universidad de Sevilla, Sevilla, Spain; Instituto de Biomedicina de Sevilla, Hospital Universitario Virgen del Rocío/Consejo Superior de Investigaciones Científicas/Universidad de Sevilla, Sevilla, Spain
| | - I Lobo-Matas
- Servicio de Medicina Interna, Hospital Universitario Virgen del Rocío
| | - E Calderón-Sandubete
- Servicio de Medicina Interna, Hospital Universitario Virgen del Rocío; Departamento de Medicina, Hospital Universitario Virgen del Rocío, Facultad de Medicina, Universidad de Sevilla, Sevilla, Spain; Instituto de Biomedicina de Sevilla, Hospital Universitario Virgen del Rocío/Consejo Superior de Investigaciones Científicas/Universidad de Sevilla, Sevilla, Spain; Centro de Investigación Biomédica en Red de Epidemiología y Salud Pública, Madrid, Spain
| | - F J Medrano-Ortega
- Servicio de Medicina Interna, Hospital Universitario Virgen del Rocío; Departamento de Medicina, Hospital Universitario Virgen del Rocío, Facultad de Medicina, Universidad de Sevilla, Sevilla, Spain; Instituto de Biomedicina de Sevilla, Hospital Universitario Virgen del Rocío/Consejo Superior de Investigaciones Científicas/Universidad de Sevilla, Sevilla, Spain; Centro de Investigación Biomédica en Red de Epidemiología y Salud Pública, Madrid, Spain
| | - J M Varela-Aguilar
- Servicio de Medicina Interna, Hospital Universitario Virgen del Rocío; Instituto de Biomedicina de Sevilla, Hospital Universitario Virgen del Rocío/Consejo Superior de Investigaciones Científicas/Universidad de Sevilla, Sevilla, Spain; Centro de Investigación Biomédica en Red de Epidemiología y Salud Pública, Madrid, Spain
| | - J Delgado-Cuesta
- Servicio de Medicina Interna, Hospital Universitario Virgen del Rocío; Departamento de Medicina, Hospital Universitario Virgen del Rocío, Facultad de Medicina, Universidad de Sevilla, Sevilla, Spain; Instituto de Biomedicina de Sevilla, Hospital Universitario Virgen del Rocío/Consejo Superior de Investigaciones Científicas/Universidad de Sevilla, Sevilla, Spain.
| |
Collapse
|
2
|
Wang Y, Yang C, Yang Q, Zhong R, Wang K, Shen H. Diagnosis of cervical lymphoma using a YOLO-v7-based model with transfer learning. Sci Rep 2024; 14:11073. [PMID: 38744888 PMCID: PMC11094110 DOI: 10.1038/s41598-024-61955-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Accepted: 05/12/2024] [Indexed: 05/16/2024] Open
Abstract
To investigate the ability of an auxiliary diagnostic model based on the YOLO-v7-based model in the classification of cervical lymphadenopathy images and compare its performance against qualitative visual evaluation by experienced radiologists. Three types of lymph nodes were sampled randomly but not uniformly. The dataset was randomly divided into for training, validation, and testing. The model was constructed with PyTorch. It was trained and weighting parameters were tuned on the validation set. Diagnostic performance was compared with that of the radiologists on the testing set. The mAP of the model was 96.4% at the 50% intersection-over-union threshold. The accuracy values of it were 0.962 for benign lymph nodes, 0.982 for lymphomas, and 0.960 for metastatic lymph nodes. The precision values of it were 0.928 for benign lymph nodes, 0.975 for lymphomas, and 0.927 for metastatic lymph nodes. The accuracy values of radiologists were 0.659 for benign lymph nodes, 0.836 for lymphomas, and 0.580 for metastatic lymph nodes. The precision values of radiologists were 0.478 for benign lymph nodes, 0.329 for lymphomas, and 0.596 for metastatic lymph nodes. The model effectively classifies lymphadenopathies from ultrasound images and outperforms qualitative visual evaluation by experienced radiologists in differential diagnosis.
Collapse
Affiliation(s)
- Yuegui Wang
- Department of Ultrasound, Zhangzhou Affiliated Hospital to Fujian Medical University, No. 59 North Shengli Road, Zhangzhou, 363000, Fujian, China
| | - Caiyun Yang
- Department of Ultrasound, Zhangzhou Affiliated Hospital to Fujian Medical University, No. 59 North Shengli Road, Zhangzhou, 363000, Fujian, China
| | - Qiuting Yang
- Department of Ultrasound, Zhangzhou Affiliated Hospital to Fujian Medical University, No. 59 North Shengli Road, Zhangzhou, 363000, Fujian, China
| | - Rong Zhong
- Department of Ultrasound, Zhangzhou Affiliated Hospital to Fujian Medical University, No. 59 North Shengli Road, Zhangzhou, 363000, Fujian, China
| | - Kangjian Wang
- Department of Ultrasound, Zhangzhou Affiliated Hospital to Fujian Medical University, No. 59 North Shengli Road, Zhangzhou, 363000, Fujian, China
| | - Haolin Shen
- Department of Ultrasound, Zhangzhou Affiliated Hospital to Fujian Medical University, No. 59 North Shengli Road, Zhangzhou, 363000, Fujian, China.
| |
Collapse
|
3
|
Schleder S, Jung EM, Schicho A, Schreyer AG, Habicher W, Grassinger J, Dollinger M. Efficacy and safety of ultrasound-guided core needle biopsies (US-CNBs) in cervical lymphadenopathy in patients with suspected head and neck cancer during the COVID-19 pandemic. Clin Hemorheol Microcirc 2023; 83:397-408. [PMID: 36683499 DOI: 10.3233/ch-221680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
BACKGROUND Cervical lymphadenopathy can be benign or malignant. Its accurate diagnosis is necessary to determine appropriate treatment. Ultrasound-guided core needle biopsies (US-CNBs) are frequently used as a percutaneous sampling approach. OBJECTIVES Our aim was to identify the efficacy and safety of US-CNBs in 125 patients with cervical lymphadenopathy and clinically suspected head and neck cancer during the COVID-19 pandemic with limited surgical resources. METHODS US-CNBs of pathological lymph nodes were performed in 146 lymph nodes on 125 patients. Biopsies were performed ultrasound-guided with a reusable gun core biopsy system and a 10-cm-long 16-G needle. Standard of reference for the histological findings were panendoscopy, clinical and sonographic follow-up, surgical biopsy or a repeat US-CNB. RESULTS Adequate material for histologic diagnosis was obtained in 111 patients (89%), of these 83 patients (75%) were diagnosed as malignant, whereas benign lymphadenopathy accounted for 28 patients (25%). Therefore, US-CNB was able to identify malignant or benign lymphadenopathy with an overall accuracy of 88% and 90%, respectively. CONCLUSIONS Percutaneous US-CNB is a safe and effective alternative to surgical biopsy in the management of cervical lymphadenopathy in patients with clinically suspected head and neck cancer in a setting with limited resources.
Collapse
Affiliation(s)
- Stephan Schleder
- Department of Diagnostic and Interventional Radiology, Merciful Brothers Hospital St. Elisabeth, Straubing, Germany
| | - Ernst-Michael Jung
- Department of Radiology, University Medical Center Regensburg, Regensburg, Germany
| | - Andreas Schicho
- Department of Radiology, University Medical Center Regensburg, Regensburg, Germany
| | - Andreas G Schreyer
- Department of Diagnostic and Interventional Radiology, University Hospital Brandenburg, Brandenburg Medical School Theodor Fontane, Neuruppin, Germany
| | - Werner Habicher
- Department of Othorhinolaryngology, Merciful Brothers Hospital St. Elisabeth, Straubing, Germany
| | - Jochen Grassinger
- Department of Hematology and Oncology, Merciful Brothers Hospital St. Elisabeth, Straubing, Germany
| | - Marco Dollinger
- Department of Radiology, University Medical Center Regensburg, Regensburg, Germany
| |
Collapse
|
4
|
Tahtabasi M, Sahiner F. Tuberculous and non-tuberculous cervical lymphadenopathy incidence and distribution in Somalia from 2016 to 2020: A review of 241 cases. World J Otorhinolaryngol Head Neck Surg 2022; 8:361-369. [PMID: 36474662 PMCID: PMC9714051 DOI: 10.1016/j.wjorl.2021.03.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Accepted: 03/10/2021] [Indexed: 12/24/2022] Open
Abstract
Objective To determine the incidence of tuberculous lymphadenitis (TBL) and other pathologies in cervical lymphadenopathies in Somalia and accompanying radiological findings. Methods In this hospital-based retrospective study, the demographic characteristics, pathology results and radiological findings of 263 patients who underwent ultrasound (US)-guided cervical lymph node biopsy between January 2016 and February 2020 were analyzed. Results Of 241 patients 118 men and 123 women (mean age 27.9 ± 18.1 years) included in the study, 46.1% (n = 111) were diagnosed as necrotizing granulomatous lymphadenitis (caseified, consistent with TBL) and 21.6% (n = 12, atypical lymphoid cells and n = 40, metastases) as malignancy. The most common type of metastasis was squamous cell cancer (n = 31), and the primary source of most of them was esophageal cancer (16/31, 51.6%). The age of patients with TBL was significantly lower than that of non-TBL (21.9 ± 14.6 vs. 41.9 ± 24.6, P = 0.003) and the incidence of TBL in pediatric patients was statistically higher (58.0% vs. 21.5%, P = 0.019). The rate of patients with TBL being localized at level 4 and level 5 was significantly more than non-TBL patients (18.0% vs. 10.0% and 23.4% vs. 10.8%, respectively, P = 0.01). Half of patients with TBL who have chest radiography had pathological findings; consolidation and bronchopneumonia were present in 52.6% of them. There were 2 patients with paravertebral abscess and one patient with gastrointestinal tuberculosis. Conclusion In Somalia, in the presence of cervical lymphadenopathy, after diagnosis by using US-guided biopsy; primarily considering of TBL and malignancy, thoracic involvement should be investigated, and esophageal carcinoma must be excluded in terms of metastatic lymph node.
Collapse
Affiliation(s)
- Mehmet Tahtabasi
- Department of RadiologyUniversity of Health Sciences‐Somalia Turkey Recep Tayyip Erdogan Education and Research HospitalMogadishuSomalia
| | - Fatih Sahiner
- Department of Medical MicrobiologyUniversity of Health Sciences‐Somalia Turkey Recep Tayyip Erdogan Education and Research HospitalMogadishuSomalia
| |
Collapse
|
5
|
Hua S, Hu X, Zhao X, Mao J. The diagnostic value and safety of modified needle aspiration biopsy for superficial lymphadenectasis. Front Surg 2022; 9:968706. [DOI: 10.3389/fsurg.2022.968706] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Accepted: 09/26/2022] [Indexed: 11/06/2022] Open
Abstract
ObjectiveTo explore the safety and diagnostic value of modified needle aspiration biopsy for superficial enlarged lymph nodes.MethodsA total of 88 patients with unknown diagnosis of superficial lymphadenopathy in our hospital (Wuxi Fifth People's Hospital) from January 2018 to July 2021 were recruited and then divided into two groups using the simple random grouping method. The study group included 48 patients who were punctured via modified needle aspiration biopsy, while the control group included 40 patients who were punctured via core needle biopsy (CNB) and had a better clinical evaluation. A BARD® automatic biopsy gun with a 18 G needle was used to puncture any enlarged lymph nodes, and specimens were obtained for pathological examination. The diagnostic positive rate of the two puncture methods was then compared and the complications involved in the two methods were observed.ResultsThe positive rate of definite pathological diagnosis was 79.2% (38/48) in the study group and 82.5% (33/40) in the control group. Both groups had similar diagnostic positive rates regarding tuberculosis and metastatic tumours in the lymph nodes (P > 0.05). Only slight bleeding was observed during the operations using the two puncture methods, with the bleeding rate of the study group 20.8% and that of the control group 15.0%, and the difference was not statistically significant (P > 0.05). No other complications were observed across both groups. Among the 48 patients with enlarged lymph nodes in the study group, there was no difference in the positive rate of diagnosis between enlarged lymph nodes larger than 20 mm and those smaller than 20 mm in the pathological, bacterial culture and cytology examinations (P > 0.05). The sensitivity, specificity, positive predictive values and negative prediction values of the improved lymph node lesions were 83.3%, 100%, 100% and 90.9%, respectively.ConclusionThe diagnostic efficacy and safety of modified needle aspiration biopsy in superficial swollen lymph nodes are equivalent to those of CNB, but the former is a more economical, simple and practical method for clinical settings and one that could be popularised in primary hospitals.
Collapse
|
6
|
[Medical examination: Preparation for ENT specialisation : Part 61]. HNO 2022; 70:630-634. [PMID: 35867113 DOI: 10.1007/s00106-022-01194-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/10/2022] [Indexed: 11/04/2022]
|
7
|
Möller K, Dietrich CF, Faiss S, Mutze S, Goelz L. [Alternatives of histological material collection - When and how is histological confirmation by ultrasound (US), computer tomography (CT) or endosonography (EUS) useful?]. ZEITSCHRIFT FUR GASTROENTEROLOGIE 2022; 60:937-958. [PMID: 34781389 DOI: 10.1055/a-1482-9448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Histological classifications of tumorous lesions together with adequate staging are necessary for stage-appropriate and personalized therapies. The indications, technical possibilities, and limitations as well as potential complications of image-guided needle biopsy by ultrasound, computed tomography, and endosonography are described. Which procedure for which organ and which lesion?
Collapse
Affiliation(s)
- Kathleen Möller
- Klinik für Innere Medizin/Gastroenterologie, Berlin, Germany, SANA-Klinikum, Berlin, Germany
| | | | - Siegbert Faiss
- Klinik für Innere Medizin/Gastroenterologie, Berlin, Germany, SANA-Klinikum, Berlin, Germany
| | - Sven Mutze
- Institut für Radiologie und Neuroradiologie, BG Unfallkrankenhaus Berlin, Berlin, Germany
- Institut für Radiologie, SANA-Klinikum, Berlin, Germany
- Institut für Diagnostische Radiologie, Universitätsmedizin Greifswald, Greifswald, Germany
| | - Leonie Goelz
- Institut für Radiologie und Neuroradiologie, BG Unfallkrankenhaus Berlin, Berlin, Germany
- Institut für Diagnostische Radiologie, Universitätsmedizin Greifswald, Greifswald, Germany
| |
Collapse
|
8
|
Yao L, Xu X, Chen G, Shen Y, Jiang W. Comparison of the Accuracy of Two Different Molecular Tests for the Diagnosis of Tuberculous Lymphadenitis Using Core Needle Biopsy Specimens: A Diagnostic Accuracy Study. Int J Gen Med 2022; 15:5237-5246. [PMID: 35655654 PMCID: PMC9153996 DOI: 10.2147/ijgm.s367127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2022] [Accepted: 05/13/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose To evaluate the diagnostic accuracy of the CapitalBio Mycobacterium real-time polymerase chain reaction assay (CapitalBio test) testing of core needle biopsy (CNB) specimens for tuberculous lymphadenitis (TBL) and to compare it with Xpert MTB/RIF. Methods We retrospectively analyzed the medical data on patients with suspected peripheral TBL. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the curve (AUC) of the CapitalBio test, Xpert MTB/RIF, and parallel test (positive result for either of these two tests) were calculated to evaluate their diagnostic efficacy compared with the final clinical diagnosis. Results The study included 114 patients. For diagnosing TBL using CNB samples, the sensitivity, specificity, PPV, NPV, and AUC were 65.0%, 100.0%, 100.0%, 28.6%, and 0.83, respectively, for the CapitalBio test; 72.0%, 100.0%, 100.0%, 33.3%, and 0.86, respectively, for Xpert MTB/RIF; and 82.0%, 100.0%, 100.0%, 43.8%, and 0.91, respectively, for the parallel test. Conclusion The accuracy of the CapitalBio test and Xpert MTB/RIF for diagnosing TBL using CNB specimens was moderate, while the sensitivity and NPV of these two tests were relatively low. The diagnostic accuracy of the CapitalBio test was slightly lower than that of Xpert MTB/RIF, but the difference between the two was not statistically significant. Parallel test might improve the diagnostic accuracy but not substantially over a single test.
Collapse
Affiliation(s)
- Liwei Yao
- Department of Nursing, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, People’s Republic of China
| | - Xudong Xu
- Zhejiang Tuberculosis Diagnosis and Treatment Center, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, People’s Republic of China
| | - Gang Chen
- Zhejiang Tuberculosis Diagnosis and Treatment Center, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, People’s Republic of China
| | - Yanqin Shen
- Zhejiang Tuberculosis Diagnosis and Treatment Center, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, People’s Republic of China
- Correspondence: Yanqin Shen, Zhejiang Tuberculosis Diagnosis and Treatment Center, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, No. 208 East Huancheng Road, Hangzhou, Zhejiang, People’s Republic of China, Email
| | - Weixian Jiang
- Department of Nursing, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, People’s Republic of China
- Weixian Jiang, Department of Nursing, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, No. 208 East Huancheng Road, Hangzhou, Zhejiang, People’s Republic of China, Email
| |
Collapse
|
9
|
Lo TH, Wang CP, Chen CN, Yang TL, Lou PJ, Ko JY, Chang YL, Chen TC. Diagnostic performance of core needle biopsy for nodal recurrences in patients with head and neck squamous cell carcinoma. Sci Rep 2022; 12:2048. [PMID: 35132145 PMCID: PMC8821564 DOI: 10.1038/s41598-022-06102-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Accepted: 01/24/2022] [Indexed: 11/25/2022] Open
Abstract
This study investigated the diagnostic accuracy and affecting factors of ultrasound (US)-guided core-needle biopsy (CNB) in patients with treated head and neck squamous cell carcinoma (HNSCC). We retrospectively reviewed patients with treated HNSCC who received US-guided CNB from January 2011 to December 2018 with corresponding imaging. Pathological necrosis and fibrosis of targeted lymph nodes (LNs) were evaluated. We analyzed the correlation between CNB accuracy and clinical and pathological characteristics. In total, 260 patients were included. The overall sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of CNB for nodal recurrence were 84.47%, 100%, 100%, 54.67%, and 86.92%, respectively. CNB of fibrotic LNs had significantly worse sensitivity, NPV, and accuracy than that of non-fibrotic LNs. Similarly, CNB of necrotic LNs had significantly worse sensitivity, NPV, and accuracy than non-necrotic LNs. Multivariate regression revealed that fibrotic LN was the only independent factor for a true positive rate, whereas both necrotic LN and fibrotic LN were independent factors for a false negative rate. The diagnostic accuracy of CNB in treated HNSCC patients is affected by LN necrosis and fibrosis. Therefore, CNB results, particularly for necrotic or fibrotic LNs, should be interpreted carefully.
Collapse
|
10
|
Shen Y, Fang L, Ye B, Xu X, Yu G, Zhou L. The Role of Core Needle Biopsy Pathology Combined with Molecular Tests in the Diagnosis of Lymph Node Tuberculosis. Infect Drug Resist 2022; 15:335-345. [PMID: 35140479 PMCID: PMC8818765 DOI: 10.2147/idr.s350570] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Accepted: 01/14/2022] [Indexed: 12/28/2022] Open
Abstract
Background Early lymph node tuberculosis (LNTB) diagnosis is still difficult. The majority of LN specimens require the undertaking of invasive and unpleasant procedures. Purpose To evaluate the diagnostic efficacy of pathology when combined with molecular tests for the diagnosis of LNTB in core needle biopsy (CNB) specimens and to compare that diagnostic efficacy with that deriving from tissue specimens’ examination alone. Methods We retrospectively analyzed the medical records of LNTB patients who met the inclusion criteria. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the curve (AUC) of pathology, molecular tests, and parallel test (positive result for either of these two assays) were calculated to evaluate their diagnostic efficacy compared with a composite reference standard. Results A total of 289 patients were included in the study. The overall sensitivity, specificity, PPV, NPV, and AUC of pathology, molecular tests, and parallel test were 94.5%, 97.2%, 99.6%, 71.4%, 0.96; 73.1%, 100.0%, 100.0%, 34.6%, 0.87; and 98.4%, 97.2%, 99.6%, 89.7%, 0.98, respectively. For CNB specimens, these values for pathology, molecular tests, and parallel test were 93.3%, 96.2%, 99.4%, 69.4%, 0.95; 76.4%, 100.0%, 100.0%, 40.0%, 0.88; and 99.4%, 96.2%, 99.4%,96.2%,0.98, while those same values for the tissue were 96.6%, 100.0%, 100.0%, 76.9%, 0.98; 67.1%, 100.0%, 100.0%, 25.6%, 0.84; and 96.6%, 100.0%, 100.0%, 76.9%,0.98, respectively. Conclusion The validity of pathology and molecular testing when using CNB specimens was similar to that of tissue specimens for relevant assessment approaches. For the LNTB diagnosis, CNB specimens were preferred for the simultaneous undertaking of pathological examination and molecular testing.
Collapse
Affiliation(s)
- Yanqin Shen
- Zhejiang Tuberculosis Diagnosis and Treatment Center, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Zhejiang Chinese Medicine and Western Medicine Integrated Hospital, Hangzhou, Zhejiang, People’s Republic of China
| | - Likui Fang
- Zhejiang Tuberculosis Diagnosis and Treatment Center, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Zhejiang Chinese Medicine and Western Medicine Integrated Hospital, Hangzhou, Zhejiang, People’s Republic of China
| | - Bo Ye
- Zhejiang Tuberculosis Diagnosis and Treatment Center, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Zhejiang Chinese Medicine and Western Medicine Integrated Hospital, Hangzhou, Zhejiang, People’s Republic of China
| | - Xudong Xu
- Zhejiang Tuberculosis Diagnosis and Treatment Center, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Zhejiang Chinese Medicine and Western Medicine Integrated Hospital, Hangzhou, Zhejiang, People’s Republic of China
| | - Guocan Yu
- Zhejiang Tuberculosis Diagnosis and Treatment Center, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Zhejiang Chinese Medicine and Western Medicine Integrated Hospital, Hangzhou, Zhejiang, People’s Republic of China
- Correspondence: Guocan Yu; Lihong Zhou, Email ;
| | - Lihong Zhou
- Zhejiang Tuberculosis Diagnosis and Treatment Center, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Zhejiang Chinese Medicine and Western Medicine Integrated Hospital, Hangzhou, Zhejiang, People’s Republic of China
| |
Collapse
|
11
|
Yu SC, Chang KC, Wang H, Li MF, Yang TL, Chen CN, Chen CJ, Chen KC, Shen CY, Kuo PY, Lin LW, Lin YM, Lin WC. Distinguishing lupus lymphadenitis from Kikuchi disease based on clinicopathological features and C4d immunohistochemistry. Rheumatology (Oxford) 2021; 60:1543-1552. [PMID: 33169134 DOI: 10.1093/rheumatology/keaa524] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 06/18/2020] [Accepted: 07/07/2020] [Indexed: 01/20/2023] Open
Abstract
OBJECTIVES Distinguishing Kikuchi disease (KD) from lupus lymphadenitis (LL) histologically is nearly impossible. We applied C4d immunohistochemical (IHC) stain to develop diagnostic tools. METHODS We retrospectively investigated clinicopathological features and C4d IHC staining in an LL-enriched development cohort (19 LL and 81 KD specimens), proposed risk stratification criteria and trained machine learning models, and validated them in an external cohort (2 LL and 55 KD specimens). RESULTS Clinically, we observed that LL was associated with an older average age (33 vs 25 years; P=0.005), higher proportion of biopsy sites other than the neck [4/19 (21%) vs 1/81 (1%); P=0.004], and higher proportion of generalized lymphadenopathy compared with KD [9/16 (56%) vs 7/31 (23%); P=0.028]. Histologically, LL involved a larger tissue area than KD did (P=0.006). LL specimens exhibited more frequent interfollicular pattern [5/19 (26%) vs 3/81 (4%); P=0.001] and plasma cell infiltrates (P=0.002), and less frequent histiocytic infiltrates in the necrotic area (P=0.030). Xanthomatous infiltrates were noted in 6/19 (32%) LL specimens. Immunohistochemically, C4d endothelial staining in the necrotic area [11/17 (65%) vs 2/62 (3%); P<10-7], and capillaries/venules [5/19 (26%) vs 7/81 (9%); P=0.048] and trabecular/hilar vessels [11/18 (61%) vs 8/81 (10%); P<10-4] in the viable area was more common in LL. During validation, both the risk stratification criteria and machine learning models were superior to conventional histological criteria. CONCLUSIONS Integrating clinicopathological and C4d findings could distinguish LL from KD.
Collapse
Affiliation(s)
- Shan-Chi Yu
- Department of Pathology and Graduate Institute of Pathology, College of Medicine, National Taiwan University, Taipei, Taiwan.,Department of Pathology, National Taiwan University Hospital, Taipei, Taiwan.,Graduate Institute of Microbiology, College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Kung-Chao Chang
- Department of Pathology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Hsuan Wang
- Department of Pathology, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu, Taiwan
| | - Meng-Fang Li
- Department of Pathology, National Taiwan University Hospital Yun-Lin Branch, Yunlin, Taiwan
| | - Tsung-Lin Yang
- Department of Otolaryngology, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei, Taiwan
| | - Chun-Nan Chen
- Department of Otolaryngology, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei, Taiwan
| | - Chih-Jung Chen
- Department of Pathology, Taichung Veterans General Hospital, Taichung, Taiwan.,School of Medicine, Chung Shan Medical University, Taichung, Taiwan
| | - Ko-Chin Chen
- Department of Pathology, Changhua Christian Hospital, Changhua, Taiwan
| | - Chieh-Yu Shen
- Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Po-Yen Kuo
- Department of Pathology, National Taiwan University Hospital Yun-Lin Branch, Yunlin, Taiwan
| | - Long-Wei Lin
- Department of Pathology, National Taiwan University Hospital Yun-Lin Branch, Yunlin, Taiwan
| | - Yueh-Min Lin
- Department of Pathology, Changhua Christian Hospital, Changhua, Taiwan
| | - Wei-Chou Lin
- Department of Pathology, National Taiwan University Hospital, Taipei, Taiwan
| |
Collapse
|
12
|
Park SG, Koo HR, Jang K, Myung JK, Song CM, Ji YB, Park JS, Tae K. Efficacy of Ultrasound-Guided Needle Biopsy in the Diagnosis of Kikuchi-Fujimoto Disease. Laryngoscope 2020; 131:E1519-E1523. [PMID: 33002212 DOI: 10.1002/lary.29160] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Revised: 08/06/2020] [Accepted: 09/21/2020] [Indexed: 12/19/2022]
Abstract
OBJECTIVES/HYPOTHESIS Ultrasound-guided fine-needle aspiration cytology (US-FNAC) is a well-established procedure performed to establish the diagnosis of Kikuchi-Fujimoto disease (KFD). Ultrasound-guided core needle biopsy (US-CNB) is an alternative diagnostic tool for KFD. However, the efficacy of US-CNB is not well evaluated. This study aimed to evaluate the efficacy of US-CNB and compare it with that of US-FNAC in the diagnosis of KFD. STUDY DESIGN Retrospective cohort study. METHODS We analyzed 170 patients who were diagnosed with KFD between January 2009 and May 2019. US-FNAC, US-CNB, and excisional biopsy were performed in 47, 114, and 9 patients, respectively. Diagnostic accuracies of US-FNAC and US-CNB were analyzed and compared. RESULTS Of the 170 patients, 45 and 125 were men and women, respectively. The mean age was 26.9 ± 9.1 years. The most common symptom was cervical lymphadenopathy, followed by fever, headache, and myalgia. The diagnosis of KFD was established primarily by US-FNAC in 21 (44.7%) of the 47 patients, by US-CNB in 109 (95.6%) of the 114 patients, and by excisional biopsy in all 9 patients. There was no specific major complication related to US-FNAC and US-CNB. CONCLUSION US-CNB can be considered safe and effective and used as the primary modality for the pathological diagnosis of KFD. LEVEL OF EVIDENCE 4. Laryngoscope, 131:E1519-E1523, 2021.
Collapse
Affiliation(s)
- Sang Gyu Park
- Department of Otolaryngology-Head and Neck Surgery, College of Medicine, Hanyang University, Seoul, Republic of Korea
| | - Hye Ryoung Koo
- Department of Radiology, College of Medicine, Hanyang University, Seoul, Republic of Korea
| | - Kiseok Jang
- Department of Pathology, College of Medicine, Hanyang University, Seoul, Republic of Korea
| | - Jae Kyung Myung
- Department of Pathology, College of Medicine, Hanyang University, Seoul, Republic of Korea
| | - Chang Myeon Song
- Department of Otolaryngology-Head and Neck Surgery, College of Medicine, Hanyang University, Seoul, Republic of Korea
| | - Yong Bae Ji
- Department of Otolaryngology-Head and Neck Surgery, College of Medicine, Hanyang University, Seoul, Republic of Korea
| | - Jeong Seon Park
- Department of Radiology, College of Medicine, Hanyang University, Seoul, Republic of Korea
| | - Kyung Tae
- Department of Otolaryngology-Head and Neck Surgery, College of Medicine, Hanyang University, Seoul, Republic of Korea
| |
Collapse
|
13
|
Warshavsky A, Rosen R, Perry C, Muhanna N, Ungar OJ, Carmel-Neiderman NN, Fliss DM, Horowitz G. Core needle biopsy for diagnosing lymphoma in cervical lymphadenopathy: Meta-analysis. Head Neck 2020; 42:3051-3060. [PMID: 32748464 DOI: 10.1002/hed.26381] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 06/06/2020] [Accepted: 06/26/2020] [Indexed: 12/17/2022] Open
Abstract
BACKGROUND The diagnostic yield of core needle biopsies (CNB) in cervical lymphadenopathy for lymphoma diagnosis is controversial. The aim of this study was to calculate the accuracy of cervical CNB in diagnosing lymphoma. METHODS We conducted a meta-analysis of all studies on patients presenting with cervical lymphadenopathy and referred to CNB. Patients with a diagnosis other than lymphoma were excluded. All cases diagnosed with lymphoma sufficient to guide treatment based on CNB outcome were considered accurate (actionable) results. A separate meta-analysis was performed for various lymphoma subtypes. RESULTS Three prospective and 19 retrospective studies, comprising 1120 patients, met the inclusion criteria. The rate of actionable lymphoma diagnoses following CNB ranged from 30% to 96.3%, with a random-effects model of 82.45% (95% confidence interval [CI] =0.76-0.88) and a fixed-effects model of 78.3% (95% CI =0.75-0.80). CONCLUSION CNB for cervical lymphadenopathy in lymphoma cases is relatively accurate in guiding treatment.
Collapse
Affiliation(s)
- Anton Warshavsky
- The Department of Otolaryngology, Head & Neck Surgery and Maxillofacial Surgery, Tel-Aviv Sourasky Medical Center, affiliated to the Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | - Roni Rosen
- The Department of Otolaryngology, Head & Neck Surgery and Maxillofacial Surgery, Tel-Aviv Sourasky Medical Center, affiliated to the Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | - Chava Perry
- The Institute of Hematology, Tel-Aviv Sourasky Medical Center, Tel-Aviv, Israel, affiliated to the Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | - Nidal Muhanna
- The Department of Otolaryngology, Head & Neck Surgery and Maxillofacial Surgery, Tel-Aviv Sourasky Medical Center, affiliated to the Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | - Omer J Ungar
- The Department of Otolaryngology, Head & Neck Surgery and Maxillofacial Surgery, Tel-Aviv Sourasky Medical Center, affiliated to the Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | - Narin Nard Carmel-Neiderman
- The Department of Otolaryngology, Head & Neck Surgery and Maxillofacial Surgery, Tel-Aviv Sourasky Medical Center, affiliated to the Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | - Dan M Fliss
- The Department of Otolaryngology, Head & Neck Surgery and Maxillofacial Surgery, Tel-Aviv Sourasky Medical Center, affiliated to the Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | - Gilad Horowitz
- The Department of Otolaryngology, Head & Neck Surgery and Maxillofacial Surgery, Tel-Aviv Sourasky Medical Center, affiliated to the Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| |
Collapse
|
14
|
The diagnostic performance of ultrasound-guided core biopsy in the diagnosis of head and neck lymphoma: results in 226 patients. Int J Oral Maxillofac Surg 2020; 50:431-436. [PMID: 32739250 DOI: 10.1016/j.ijom.2020.07.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Revised: 04/30/2020] [Accepted: 07/02/2020] [Indexed: 01/21/2023]
Abstract
Many clinical guidelines for investigating lymphomas advise that surgical excision biopsy (SEB) should be performed for a confident diagnosis. It is increasingly recognized in clinical practice that ultrasound-guided core needle biopsy (USCNB) is a reliable diagnostic technique. We aimed to investigate the diagnostic efficacy of USCNB in head and neck lymphoma. A retrospective analysis of all diagnosed head and neck lymphomas between 2013 and 2018 was performed. Patient records, radiology and histopathology reports along with the biopsy technique: fine needle aspiration cytology (FNAC), USCNB, and SEB used were reviewed. The technique providing diagnosis and leading to initiation of treatment was identified. Two-hundred and thirty patients and 267 biopsy samples were included. A total of 226 patients underwent USCN. In 215 of 226 (95.1%) USCNB patients were fully diagnostic allowing for initiation of oncological treatment; 11 patients required a subsequent SEB to provide diagnosis. In four patients, SEB was the only investigation performed. Of the USCNB total number of procedures (number of patients n=230 is the same coincidentally as the number of USCNB procedures), 215 of 230 (93.5%) were fully diagnostic samples. In the majority of cases, USCNB provided a definitive diagnosis allowing initiation of oncological treatment, avoiding the need for SEB. USCNB should be considered the first-line diagnostic modality in appropriate cases, as it reduces time to initiate treatment, costs and avoids patients having to undergo unnecessary surgery and possible complications.
Collapse
|
15
|
Elhamdoust E, Motamedfar A, Gharibvand MM, Jazayeri SN. Investigation of the value of ultrasound-guided core needle biopsy from pathologic lymph nodes to the diagnosis of lymphoma. J Family Med Prim Care 2020; 9:2801-2805. [PMID: 32984129 PMCID: PMC7491826 DOI: 10.4103/jfmpc.jfmpc_1260_19] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Revised: 03/06/2020] [Accepted: 04/13/2020] [Indexed: 12/14/2022] Open
Abstract
Introduction: In recent years, techniques with minimally invasive have been gradually developed and used in the diagnosis of lymphoma. Among minimally invasive techniques, core needle biopsy (CNB) has been widely accepted as an effective tool for the diagnosis of malignant lymphoma, carcinoma and deep tumors that are only accessible via CT or endoscopic-guided. This study was conducted to investigate of diagnostic value of ultrasound guided CNB in the diagnosis of lymphoma in all parts of the body compared to surgical excisional biopsy (SEB). Materials and Methods: This is an descriptive epidemiological study that was performed on patients with suspected lymphoma referred to the intervention ward of Golestan Hospital in Ahvaz in 2019. For all patients with suspected lymphoma, CNB of lymph nodes was performed by ultrasound-guided. Finally, the final diagnosis of CNB was compared with the results of surgical biopsy in the studied specimens. Results: In this study, 40 patients were evaluated with suspected lymphoma. At initial diagnosis with CNB, 12 (30%) had NHL, 19 (47.5%) had Hodgkin's lymphoma, and 2 had high-grade lymphoma. Of the 40 patients examined, 29 required IHC to confirm the diagnosis. In 8 cases, the final diagnosis was done using SEB. Final diagnosis in 9 (22.5%) patients was confirmed by CNB only. The CNB along with the IHC also led to the final diagnosis in 23 (57.5%) patients. However, another 8 patients required biopsy to confirm the diagnosis by SEB. Conclusion: The findings of this study indicated that US-CNB is a highly efficient method of diagnosis of lymphoma with high specificity, in the fastest possible mode and with the least complications.
Collapse
Affiliation(s)
- Elham Elhamdoust
- Department of Radiology, Golestan Hospital, Ahvaz Jundishapur University of Medicine, Ahvaz, Iran
| | - Azim Motamedfar
- Department of Radiology, Golestan Hospital, Ahvaz Jundishapur University of Medicine, Ahvaz, Iran
| | | | | |
Collapse
|
16
|
Wilczynski A, Görg C, Timmesfeld N, Ramaswamy A, Neubauer A, Burchert A, Trenker C. Value and Diagnostic Accuracy of Ultrasound-Guided Full Core Needle Biopsy in the Diagnosis of Lymphadenopathy: A Retrospective Evaluation of 793 Cases. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2020; 39:559-567. [PMID: 31584214 DOI: 10.1002/jum.15134] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Accepted: 08/07/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVES Whole surgical lymph node excision (SNE) is considered the standard diagnostic method in the primary diagnosis of lymphadenopathy (LA) suspected of malignancy. Ultrasound-guided full core needle biopsy (UFCNB) offers an alternative method to SNE. This study examined the accuracy of UFCNB in the diagnosis of unexplained LA in 793 cases. METHODS From January 2006 to June 2015, a total of 793 cases of LA of unknown origin received a UFCNB. The lymph nodes were located peripherally (68%) or abdominally (32%). The final diagnoses from histopathologic examinations were non-Hodgkin lymphoma (n = 245), Hodgkin lymphoma (n = 53), solid nonlymphocytic lymph node metastases (n = 359), and benign LA (n = 136). The results of the biopsies were retrospectively evaluated with regard to sensitivity, specificity, and diagnostic accuracy. RESULTS In the total collective of 793 biopsies, the sensitivity of UFCNB was 94.4%; the specificity was 97.8%; and the diagnostic accuracy was 95.0%. In the subgroups, the following results were obtained: non-Hodgkin lymphoma (sensitivity, 97.2%), Hodgkin lymphoma (sensitivity, 88.7%), metastases (sensitivity, 93.3%), and benign LA (specificity, 97.8%). In 17 cases (2.2%), an additional rebiopsy of the lymph node was needed, and in 85 cases (10.7%), an additional SNE was performed. CONCLUSIONS Due to the diagnostic accuracy of 95.0% in the total collective, UFCNB seems to be an alternative diagnostic procedure to the standard procedure of SNE for LA of unknown origin. A prospective comparative study to definitively clarify the diagnostic value of UFCNB compared to SNE in the unexplained LA is warranted.
Collapse
Affiliation(s)
- Alexandra Wilczynski
- Department of Internal Medicine, Divisions of Gastroenterology, University Hospital Marburg und Giessen, Marburg, Germany
| | - Christian Görg
- Department of Internal Medicine, Divisions of Gastroenterology, University Hospital Marburg und Giessen, Marburg, Germany
| | - Nina Timmesfeld
- Institute for Medical Biometry and Epidemiology, Bochum, Germany
| | - Annette Ramaswamy
- Department of Pathology, University Hospital Marburg und Giessen, Marburg, Germany
| | - Andreas Neubauer
- Department of Hematology, Oncology, and Immunology, University Hospital Marburg und Giessen, Marburg, Germany
| | - Andreas Burchert
- Department of Hematology, Oncology, and Immunology, University Hospital Marburg und Giessen, Marburg, Germany
| | - Corinna Trenker
- Department of Hematology, Oncology, and Immunology, University Hospital Marburg und Giessen, Marburg, Germany
| |
Collapse
|
17
|
Yoon S, Ryu KH, Baek HJ, Kim TH, Moon JI, Choi BH, Park SE, Ha JY, Song DH, An HJ, Heo YJ. Cervical Lymph Nodes Detected by F-18 FDG PET/CT in Oncology Patients: Added Value of Subsequent Ultrasonography for Determining Nodal Metastasis. ACTA ACUST UNITED AC 2019; 56:medicina56010016. [PMID: 31906183 PMCID: PMC7022812 DOI: 10.3390/medicina56010016] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2019] [Revised: 12/29/2019] [Accepted: 12/30/2019] [Indexed: 11/16/2022]
Abstract
Background and Objectives: To investigate the diagnostic performance of F-18 fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) and subsequent ultrasonography (US) for determining cervical nodal metastasis in oncology patients. Materials and Methods: Fifty-nine cervical lymph nodes (LNs) initially detected by PET/CT with subsequent neck US were included in this retrospective study. All LNs were subjected to US-guided fine-needle aspiration or core needle biopsy. The maximum standardized uptake value (SUVmax) and sonographic features were assessed. Results: Forty-three of 59 cervical LNs detected by PET/CT were malignant. PET/CT alone showed a highest diagnostic value for metastatic LNs with 81.4% sensitivity, 68.8% specificity, and 78% accuracy when SUVmax ≥5.8 was applied as an optimal cut-off value. Combined PET/CT and subsequent US diagnoses for determining nodal metastasis showed the following diagnostic performance: 81.4% sensitivity, 87.5% specificity, and 83.1% accuracy. There was a significant difference in the diagnostic performance between the two diagnostic imaging approaches (p = 0.006). Conclusions: Combined diagnosis using subsequent US showed a significantly higher diagnostic performance for determining nodal metastasis in the neck. Therefore, we believe that our proposed diagnostic strategy using subsequent US can be helpful in evaluating cervical LNs on PET/CT. Moreover, our results clarify the need for US-guided tissue sampling in oncology patients.
Collapse
Affiliation(s)
- Seokho Yoon
- Department of Nuclear Medicine and Molecular Imaging, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, 11 Samjeongja-ro, Seongsan-gu, Changwon 51472, Korea;
| | - Kyeong Hwa Ryu
- Department of Radiology, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, 11 Samjeongja-ro, Seongsan-gu, Changwon 51472, Korea; (K.H.R.); (J.I.M.); (B.H.C.); (S.E.P.); (J.Y.H.)
| | - Hye Jin Baek
- Department of Radiology, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, 11 Samjeongja-ro, Seongsan-gu, Changwon 51472, Korea; (K.H.R.); (J.I.M.); (B.H.C.); (S.E.P.); (J.Y.H.)
- Department of Radiology, Institute of Health Sciences, Gyeongsang National University School of Medicine, 816-15 Jinju-daero, Jinju 52727, Korea
- Correspondence: ; Tel.: +82-55-214-3140
| | - Tae Hoon Kim
- Department of Internal Medicine, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, 11 Samjeongja-ro, Seongsan-gu, Changwon 51472, Korea;
| | - Jin Il Moon
- Department of Radiology, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, 11 Samjeongja-ro, Seongsan-gu, Changwon 51472, Korea; (K.H.R.); (J.I.M.); (B.H.C.); (S.E.P.); (J.Y.H.)
| | - Bo Hwa Choi
- Department of Radiology, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, 11 Samjeongja-ro, Seongsan-gu, Changwon 51472, Korea; (K.H.R.); (J.I.M.); (B.H.C.); (S.E.P.); (J.Y.H.)
| | - Sung Eun Park
- Department of Radiology, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, 11 Samjeongja-ro, Seongsan-gu, Changwon 51472, Korea; (K.H.R.); (J.I.M.); (B.H.C.); (S.E.P.); (J.Y.H.)
| | - Ji Young Ha
- Department of Radiology, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, 11 Samjeongja-ro, Seongsan-gu, Changwon 51472, Korea; (K.H.R.); (J.I.M.); (B.H.C.); (S.E.P.); (J.Y.H.)
| | - Dae Hyun Song
- Department of Pathology, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, 11 Samjeongja-ro, Seongsan-gu, Changwon 51472, Korea; (D.H.S.); (H.J.A.)
| | - Hyo Jung An
- Department of Pathology, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, 11 Samjeongja-ro, Seongsan-gu, Changwon 51472, Korea; (D.H.S.); (H.J.A.)
| | - Young Jin Heo
- Department of Radiology, Busan Paik Hospital, Inje University College of Medicine, 75, Bokji-ro, Busanjin-gu, Busan 47392, Korea
| |
Collapse
|
18
|
Cheng Z, Liang P. US-guided core needle biopsy under assistance of hydrodissection to diagnose small lymph node metastases adjacent to cervical large vessels. ACTA ACUST UNITED AC 2019; 25:122-126. [PMID: 30860075 DOI: 10.5152/dir.2019.18166] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
PURPOSE We aimed to evaluate the safety and effectiveness of ultrasonography (US) guided core needle biopsy (CNB) with hydrodissection to diagnose small lymph node metastases adjacent to cervical large vessels. METHODS From January 2013 to October 2017, 31 patients with 31 cervical lymph node metastases adjacent to large vessels presented for US-guided CNB. The mean maximal diameter of lymph nodes was 0.93±0.16 cm (range, 0.6-1.2 cm). All patients underwent US-guided CNB with 18-gauge true-cut biopsy needle after hydrodissection with saline. The separation success rate (SSR) of the hydrodissection, technical success rate (TSR) of CNB, histopathologic success rate (HST), and complications were assessed. RESULTS The SSR of hydrodissection was 100% (31/31). After effective separation between the lymph node metastases and the adjacent large vessels with saline injection, the procedures of CNB were performed with a TSR of 100% (31/31). The HST of the lymph node metastases was 100% (31/31). Two patients complained of mild cervical swelling sensation during saline injection. No major complications such as injury of the large vessels or massive hemorrhage occurred. CONCLUSION Hydrodissection can facilitate safely and effectively US-guided CNB of subcentimeter cervical lymph nodes adjacent to large vessels, potentially impacting further therapeutic decisions.
Collapse
Affiliation(s)
- Zhigang Cheng
- Department of Interventional Ultrasound, Chinese PLA General Hospital, Beijing, People's Republic of China
| | - Ping Liang
- Department of Interventional Ultrasound, Chinese PLA General Hospital, Beijing, People's Republic of China
| |
Collapse
|
19
|
Pritzker KPH, Nieminen HJ. Needle Biopsy Adequacy in the Era of Precision Medicine and Value-Based Health Care. Arch Pathol Lab Med 2019; 143:1399-1415. [PMID: 31100015 DOI: 10.5858/arpa.2018-0463-ra] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
CONTEXT.— Needle biopsy of diseased tissue is an essential diagnostic tool that is becoming even more important as precision medicine develops. However, the capability of this modality to efficiently provide samples adequate for diagnostic and prognostic analysis remains quite limited relative to current diagnostic needs. For physicians and patients, inadequate biopsy frequently leads to diagnostic delay, procedure duplication, or insufficient information about tumor biology leading to delay in treatment; for health systems, this results in substantial incremental costs and inefficient use of scarce specialized diagnostic resources. OBJECTIVE.— To review current needle biopsy technology, devices, and practice with a perspective to identify current limitations and opportunities for improvement in the context of advancing precision medicine. DATA SOURCES.— PubMed searches of fine-needle aspiration and core needle biopsy devices and similar technologies were made generally, by tissue site, and by adequacy as well as by health economics of these technologies. CONCLUSIONS.— Needle biopsy adequacy can be improved by recognizing the importance of this diagnostic tool by promoting common criteria for needle biopsy adequacy; by optimizing needle biopsy procedural technique, technologies, clinical practice, professional education, and quality assurance; and by bundling biopsy procedure costs with downstream diagnostic modalities to provide better accountability and incentives to improve the diagnostic process.
Collapse
Affiliation(s)
- Kenneth P H Pritzker
- From the Departments of Laboratory Medicine and Pathobiology, and Surgery, University of Toronto, Toronto, Ontario, Canada (Dr Pritzker); and the Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland (Dr Nieminen)
| | - Heikki J Nieminen
- From the Departments of Laboratory Medicine and Pathobiology, and Surgery, University of Toronto, Toronto, Ontario, Canada (Dr Pritzker); and the Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland (Dr Nieminen)
| |
Collapse
|
20
|
Garg P, Pathak P, Goyal R, Arora VK, Singh N. Current practice in handling and reporting needle biopsies: A hospital-based survey. INDIAN J PATHOL MICR 2018; 61:197-200. [PMID: 29676356 DOI: 10.4103/ijpm.ijpm_93_17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Context Core-needle biopsy (CNB) is a minimally invasive screening and diagnostic tool which provides intact tissue fragments for histopathological examination. Aims This study was conducted to review the current practices of handling and reporting CNBs performed for core-needle biopsies from four organ systems which are frequently encountered in our institution. These include breast, prostate, soft tissues, and lymph nodes. Settings and Design This was a retrospective study conducted at a tertiary care hospital. Materials and Methods CNB reports of breast, prostate, soft tissue, and lymph nodes were accessed and categorized based on the site of biopsy, number, and average length of the cores. The CNB reports were categorized into diagnostic or nondiagnostic. In case of diagnosis of malignancy, reports were recorded as structured or nonstructured reports. Statistical Analysis Used Fisher's exact test and Chi-square tests were applied to check the significance of the results obtained on comparing the number of cores and size of cores with the outcome of report. Results Out of 16,300 surgical pathology specimens received, 400 were CNBs comprising breast (n = 211), prostate (n = 108), soft tissue (n = 50), and lymph node (n = 31). Majority of the CNBs had 2-5 cores and the size of the core was ≥0.5 cm, which accounted for most of the reports which were diagnostic. There was a lack of clinical and radiological detail in many of the cases. Out of the malignant cases diagnosed, structured reports were given in 30% of breast, 79.3% of prostate, 41.7% soft tissue, and 60% of lymph node needle biopsies. Conclusions The audit helped to identify areas of improvement in CNB services.
Collapse
Affiliation(s)
- Paritosh Garg
- Department of Pathology, University College of Medical Sciences and Guru Teg Bahadur Hospital, New Delhi, India
| | - Priya Pathak
- Department of Pathology, University College of Medical Sciences and Guru Teg Bahadur Hospital, New Delhi, India
| | - Rachna Goyal
- Department of Pathology, University College of Medical Sciences and Guru Teg Bahadur Hospital, New Delhi, India
| | - Vinod K Arora
- Department of Pathology, University College of Medical Sciences and Guru Teg Bahadur Hospital, New Delhi, India
| | - Navjeevan Singh
- Department of Pathology, University College of Medical Sciences and Guru Teg Bahadur Hospital, New Delhi, India
| |
Collapse
|
21
|
Efficacy of ultrasound-guided core needle biopsy in cervical lymphadenopathy: A retrospective study of 6,695 cases. Eur Radiol 2017; 28:1809-1817. [DOI: 10.1007/s00330-017-5116-1] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2017] [Revised: 09/20/2017] [Accepted: 10/02/2017] [Indexed: 12/26/2022]
|
22
|
Borhani AA, Monaco SE. Chapter 7 Image-Guided Fine-Needle Aspiration and Core Needle Biopsy of Neck Lymph Nodes: Techniques, Pearls, and Pitfalls. Semin Ultrasound CT MR 2017; 38:531-541. [DOI: 10.1053/j.sult.2017.05.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
23
|
Strassen U, Geisweid C, Hofauer B, Knopf A. Sonographic differentiation between lymphatic and metastatic diseases in cervical lymphadenopathy. Laryngoscope 2017; 128:859-863. [DOI: 10.1002/lary.26837] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 06/22/2017] [Accepted: 07/13/2017] [Indexed: 12/25/2022]
Affiliation(s)
- Ulrich Strassen
- Department of Otorhinolaryngology/Head and Neck Surgery; Technical University of Munich; Munich Germany
| | - Christina Geisweid
- Department of Otorhinolaryngology/Head and Neck Surgery; Technical University of Munich; Munich Germany
| | - Benedikt Hofauer
- Department of Otorhinolaryngology/Head and Neck Surgery; Technical University of Munich; Munich Germany
| | - Andreas Knopf
- Department of Otorhinolaryngology/Head and Neck Surgery; Technical University of Munich; Munich Germany
| |
Collapse
|