1
|
Podnar S, Omejec G. Clinical and neurophysiological recovery of ulnar nerve conduction block at the elbow. Muscle Nerve 2023; 68:722-728. [PMID: 37421240 DOI: 10.1002/mus.27928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 06/01/2023] [Accepted: 06/18/2023] [Indexed: 07/10/2023]
Abstract
INTRODUCTION/AIMS An important mechanism of peripheral nerve motor and sensory dysfunction is conduction block (CB). However, recovery from mechanically induced CB has been rarely studied in humans. The aim of this study was to describe clinical, electrodiagnostic (EDx), and ultrasonographic (US) characteristics of CB recovery in ulnar neuropathy at the elbow (UNE). METHODS We recruited a group of consecutive patients presenting to our EDx laboratory with UNE and >50% motor CB. Patients' histories were obtained and neurologic, EDx, and US examinations were repeated every 1-3 mo for at least 12 mo. RESULTS We studied 10 patients (5 men), with a mean age of 63 y (range, 51-81 y). In all affected arms CB was localized to the retrocondylar groove. Following conservative management, myometrically measured index finger abduction improved from a median of 49% to 100% relative to the contralateral index finger, and ulnar nerve CB decreased from a median of 74% to 6%. Most of the improvement took place within 8 mo of symptom onset, and 6 mo after receiving treatment instructions. Mean motor nerve conduction velocity improved from 15 to 27 m/s in the most affected 2-cm ulnar nerve segment. DISCUSSION The resolution of CB after typical chronic compression may take longer than after acute compression. This should be considered by clinicians when estimating prognosis for discussions with patients.
Collapse
Affiliation(s)
- Simon Podnar
- Division of Neurology, Institute of Clinical Neurophysiology, University Medical Centre Ljubljana, Ljubljana, Slovenia
| | - Gregor Omejec
- Division of Neurology, Institute of Clinical Neurophysiology, University Medical Centre Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
2
|
Bink T, Hazewinkel MHJ, Hundepool CA, Duraku LS, Drenthen J, Gfrerer L, Zuidam JM. Feasibility of Ultrasound Measurements of Peripheral Sensory Nerves in Head and Neck Area in Healthy Subjects. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2023; 11:e5343. [PMID: 37829106 PMCID: PMC10566885 DOI: 10.1097/gox.0000000000005343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Accepted: 09/06/2023] [Indexed: 10/14/2023]
Abstract
Background Current diagnostic methods for nerve compression headaches consist of diagnostic nerve blocks. A less-invasive method that can possibly aid in the diagnosis is ultrasound, by measuring the cross-sectional area (CSA) of the affected nerve. However, this technique has not been validated, and articles evaluating CSA measurements in the asymptomatic population are missing in the current literature. Therefore, the aim of this study was to determine the feasibility of ultrasound measurements of peripheral extracranial nerves in the head and neck area in asymptomatic individuals. Methods The sensory nerves of the head and neck in healthy individuals were imaged by ultrasound. The CSA was measured at anatomical determined measurement sites for each nerve. To determine the feasibility of ultrasound measurements, the interrater reliability and the intrarater reliability were determined. Results In total, 60 healthy volunteers were included. We were able to image the nerves at nine of 11 measurement sites. The mean CSA of the frontal nerves ranged between 0.80 ± 0.42 mm2 and 1.20 ± 0.43 mm2, the mean CSA of the occipital nerves ranged between 2.90 ± 2.73 mm2 and 3.40 ± 1.91 mm2, and the mean CSA of the temporal nerves ranged between 0.92 ± 0.26 mm2 and 1.40 ± 1.11 mm2. The intrarater and interrater reliability of the CSA measurements was good (ICC: 0.75-0.78). Conclusions Ultrasound is a feasible method to evaluate CSA measurements of peripheral extracranial nerves in the head and neck area. Further research should be done to evaluate the use of ultrasound as a diagnostic tool for nerve compression headache.
Collapse
Affiliation(s)
- Thijs Bink
- From the Department of Plastic, Reconstructive Surgery and Hand Surgery, Erasmus Medical Center Rotterdam, the Netherlands
| | - Merel H J Hazewinkel
- From the Department of Plastic, Reconstructive Surgery and Hand Surgery, Erasmus Medical Center Rotterdam, the Netherlands
| | - Caroline A Hundepool
- From the Department of Plastic, Reconstructive Surgery and Hand Surgery, Erasmus Medical Center Rotterdam, the Netherlands
| | - Liron S Duraku
- Department of Plastic, Reconstructive Surgery and Hand Surgery, Amsterdam UMC, Amsterdam, the Netherlands
| | - Judith Drenthen
- Department of Neurology, Erasmus MC, University Medical Center, Rotterdam, the Netherlands
| | - Lisa Gfrerer
- Division of Plastic and Reconstructive Surgery, Weill Cornell Medical Center, New York, N.Y
| | - J Michiel Zuidam
- From the Department of Plastic, Reconstructive Surgery and Hand Surgery, Erasmus Medical Center Rotterdam, the Netherlands
| |
Collapse
|
3
|
Abraham A, Fainmesser Y, Drory VE, Bril V. Quantitative sonographic assessment of muscle thickness and fasciculations distribution is a sensitive tool for neuromuscular disorders. PLoS One 2023; 18:e0292123. [PMID: 37768998 PMCID: PMC10538738 DOI: 10.1371/journal.pone.0292123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 09/12/2023] [Indexed: 09/30/2023] Open
Abstract
INTRODUCTION Loss of muscle thickness can be demonstrated in a wide spectrum of neuromuscular disorders, while fasciculations are more frequent in amyotrophic lateral sclerosis (ALS). In the current study, we aimed to determine the sensitivity and specificity of quantitative sonographic assessment of muscle thickness and the presence of fasciculations for diagnosing various neuromuscular disorders. METHODS The thickness and the presence of fasciculations in eight muscles were determined by sonography in patients with myopathy (22), polyneuropathy (36), ALS (91), and spinal muscular atrophy (SMA) (31) and compared to normative values determined in 65 heathy control subjects. RESULTS Reduced muscle thickness in at least one relaxed muscle showed 92-100% sensitivity for diagnosing a neuromuscular disease, with a specificity of 85% for differentiating patients from heathy controls (AUC = 0.90). Subtracting distal from proximal muscle thickness may differentiate between myopathy and polyneuropathy. Fasciculations in ≥1 proximal muscle showed good diagnostic accuracy (AUC = 0.87) for diagnosing ALS. DISCUSSION Sonographic assessment of muscle thickness is a sensitive tool for diagnosing a wide spectrum of neuromuscular diseases, and may facilitate diagnosis even in patients with normal strength on neurological examination, while the presence of fasciculations in proximal muscles may facilitate ALS diagnosis.
Collapse
Affiliation(s)
- Alon Abraham
- Neuromuscular Diseases Unit, Department of Neurology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
- Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | - Yaara Fainmesser
- Neuromuscular Diseases Unit, Department of Neurology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - Vivian E. Drory
- Neuromuscular Diseases Unit, Department of Neurology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
- Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | - Vera Bril
- Ellen and Martin Prosserman Centre for Neuromuscular Diseases, Division of Neurology, Department of Medicine, University Health Network, University of Toronto, Toronto, Canada
| |
Collapse
|
4
|
Yavuz K, Yurdakul FG, Guler T, Bodur H. Predictive value of ultrasonography in polyneuropathy diagnosis: electrophysiological and ultrasonographic analysis. Rheumatol Int 2023; 43:1733-1742. [PMID: 37318545 DOI: 10.1007/s00296-023-05356-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 05/30/2023] [Indexed: 06/16/2023]
Abstract
Peripheral neuropathy may cause serious complications such as foot ulcers and Charcot joint which can prevent by early diagnosis. We aimed to analyze the diagnostic value of ultrasonographic measurements of nerves and muscles in distal symmetric axonal polyneuropathy (DSAP). Study included 51 DSAP patients and 51 controls. Nerve conduction studies were performed. Median, ulnar, tibial, superficial peroneal, and sural nerves and the abductor pollicis brevis (APB), abductor digiti minimi (ADM), first dorsal interosseous (FDI), extensor digitorum brevis (EDB), abductor hallucis (AH) and tibialis anterior (TA) muscles were evaluated with ultrasound. The Toronto clinical scoring system (TCSS) was used to assess the severity of neuropathy. The median, ulnar, and tibial nerve cross-sectional areas (CSA) were higher in the DSAP group (p = 0.025, p = 0.011, p < 0.001 respectively) while superficial peroneal and sural nerve CSAs were not differed. Only AH and EDB ultrasonographic findings from the muscles differed between the two groups. Effect of diabetes and DSAP on sonographic findings were assessed with two-way ANOVA. Results indicated that only DSAP had a significant effect on sonographic nerve and muscle examination. The area under the ROC curve was 0.831 ± 0.042 for tibial nerve CSA (p < 0.001) with a cut-off value of 15.5 mm2 (sensitivity 74% and specificity 83%). Median, ulnar and tibial nerve CSAs were found to be larger in polyneuropathy patients and they were associated with the clinical and electrophysiological severity of polyneuropathy. ROC analysis showed that tibial nerve CSA may have a predictive value in the diagnosis of DSAP.
Collapse
Affiliation(s)
- Kaan Yavuz
- Department of Physical Medicine and Rehabilitation, Ankara City Hospital, Ankara, Turkey
- Physical Therapy and Rehabilitation, Haymana State Hospital, Ankara, Turkey
| | - Fatma Gul Yurdakul
- Department of Physical Medicine and Rehabilitation Hospital, University of Health Sciences Ankara City Hospital, Üniversiteler Mah 1604. Cadde No: 9, 06800, Çankaya/Ankara, Turkey.
| | - Tuba Guler
- Department of Physical Medicine and Rehabilitation Hospital, University of Health Sciences Ankara City Hospital, Üniversiteler Mah 1604. Cadde No: 9, 06800, Çankaya/Ankara, Turkey
| | - Hatice Bodur
- Department of Physical Medicine and Rehabilitation, Yıldırım Beyazıt University, Ankara City Hospital, Ankara, Turkey
| |
Collapse
|
5
|
Haelewijn N, Peters Dickie JL, Staes F, Vereecke E, Deschamps K. Current evidence regarding 2D ultrasonography monitoring of intrinsic foot muscle properties: A systematic review. Heliyon 2023; 9:e18252. [PMID: 37520980 PMCID: PMC10374929 DOI: 10.1016/j.heliyon.2023.e18252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 07/10/2023] [Accepted: 07/12/2023] [Indexed: 08/01/2023] Open
Abstract
Background Ultrasonography can discriminate between intrinsic and extrinsic foot muscle properties and has therefore gained considerable popularity as an indirect strength evaluation. However, an overview on the use of ultrasound for assessing intrinsic foot musculature (IFM) is currently lacking. Research question What is the current evidence regarding (1) 2D ultrasonography protocols and its reliability? (2) Reference values for cross-sectional area and dorso-plantar thickness evaluation in asymptomatic and symptomatic persons? Methods The PRISMA guidelines were used to conduct this systematic review. Eight databases (PubMed, Embase, Web of Science, Cochrane Library, Scopus, CINAHL, SPORTDiscus and EuropePMC) were searched up to November 1, 2021. Studies reporting quantitative 2D ultrasound findings of the intrinsic foot muscles with no limitation to sex, BMI, ethnicity or physical activity were included. Studies were assessed for methodological quality using the Downs and Black checklist. Results Fifty-three studies were retained. Protocols showed an overall good to great reliability, suggesting limits of agreement between 8 and 30% of relative muscle size with minimal detectable changes varying from 0.10 to 0.29 cm2 for cross-sectional area and 0.03-0.23 cm for thickness. Reference values are proposed for both cross-sectional area and thickness measurements of the abductor hallucis, flexor digitorum brevis, flexor hallucis brevis and quadratus plantae in asymptomatic persons. This could not be performed in the symptomatic studies due to a limited number of relevant studies addressing the symptomatic population, therefore a clinical overview is outlined. Clinically, IFM properties have been studied in ten distinct pathological conditions, predominantly pointing towards decreased muscle properties of the abductor hallucis. Significance We provide a clear and comprehensive overview of the literature regarding 2D ultrasonography of the IFM, making the available evidence more accessible to decision makers and researchers.
Collapse
Affiliation(s)
- Nicolas Haelewijn
- Department of Rehabilitation Sciences, Musculoskeletal Rehabilitation Research Group, KU Leuven, Spoorwegstraat 12, 8200 Brugge, Belgium
| | - Jean-Louis Peters Dickie
- Neuromusculoskeletal Lab (NMSK), Secteur des Sciences de la Santé, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Brussels, Belgium
| | - Filip Staes
- Department of Rehabilitation Sciences, Musculoskeletal Rehabilitation Research Group, KU Leuven, Tervuursevest 101, 3000 Leuven, Belgium
| | - Evie Vereecke
- Department of Development & Regeneration, Muscles & Movement Group, KU Leuven, Etienne Sabbelaan 53, 8500 Kortrijk, Belgium
| | - Kevin Deschamps
- Department of Rehabilitation Sciences, Musculoskeletal Rehabilitation Research Group, KU Leuven, Spoorwegstraat 12, 8200 Brugge, Belgium
- Haute Ecole Leonard De Vinci, Division of Podiatry, Avenue E. Mounier 84, 1200 Sint-Lambrechts-Woluwe, Belgium
| |
Collapse
|
6
|
Karademir F, Ayhan Kuru C, Arın G, Soylu R. Morphometry of thenar muscles by water bath ultrasonography in trapeziometacarpal osteoarthritis: intra- and inter-rater reliability. J Hand Surg Eur Vol 2023; 48:115-122. [PMID: 36281061 DOI: 10.1177/17531934221130669] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
We studied the intra- and inter-rater reliability of muscle thickness and cross-sectional area measurements of thenar muscles with a water bath ultrasonography technique in eight healthy volunteers and 16 patients with trapeziometacarpal osteoarthritis. Thickness and cross-sectional area of the opponens pollicis, abductor pollicis brevis, flexor pollicis brevis, first dorsal interosseous and adductor pollicis muscle were measured. The results showed changes in the morphometric properties of the thenar muscles in patients with trapeziometacarpal osteoarthritis (TMC OA) compared with the healthy volunteers. In the dominant-sided patients (n = 14), there were lower cross-sectional area values for the abductor pollicis brevis and opponens pollicis muscles. In the non-dominant-sided patients (n = 10), there were lower cross-sectional area values for the abductor pollicis brevis and flexor pollicis brevis and lower muscle thickness of the abductor pollicis brevis. The water bath ultrasonography technique could be used to diagnose and treat diseases where changes in thenar muscle thickness and cross-sectional area can be expected.Level of evidence: III.
Collapse
Affiliation(s)
- Feray Karademir
- Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey
| | - Cigdem Ayhan Kuru
- Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey
| | - Gamze Arın
- Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey
| | - Ruhi Soylu
- Department of Biophysics, Faculty of Medicine, Hacettepe University, Ankara, Turkey
| |
Collapse
|
7
|
Ultrasound of Thumb Muscles and Grasp Strength in Early Thumb Carpometacarpal Osteoarthritis. J Hand Surg Am 2022; 47:898.e1-898.e8. [PMID: 34509311 DOI: 10.1016/j.jhsa.2021.07.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 05/07/2021] [Accepted: 07/21/2021] [Indexed: 02/02/2023]
Abstract
PURPOSE The pathophysiology of thumb carpometacarpal (CMC) osteoarthritis (OA) involves complex interactions between the ligaments and muscles supporting the joint. Factors such as muscle volume and strength may be more relevant in early disease. We used ultrasound as a noninvasive method to explore differences in the intrinsic hand muscles of patients with early CMC OA, as determined using physical exam and radiographs, and healthy controls. We also assessed differences in grip strength. METHODS A convenience sample of postmenopausal women with early CMC OA diagnosed using a physical examination or radiographs was recruited from an orthopedic clinic specializing in hand surgery. Healthy controls who were matched for age and hand dominance were recruited from the same clinic. We used ultrasound to determine the length of the first metacarpal and the muscle thickness of the abductor pollicis brevis, opponens pollicis (OPP), and first dorsal interosseous. Grip strength measurements were taken using a standard Jamar dynamometer and 2 custom-designed tools for cylindrical grasp and pinch strength. RESULTS Twenty-three subjects were enrolled, with a total of 32 thumbs measured: 15 thumbs with arthritis and 17 healthy thumbs. Multivariable logistic regression models indicated that thumbs with thicker OPP had 0.85 lower odds (95% CI = 0.71-0.97) of early OA, adjusting for hand dominance and the first metacarpal length. Linear regression models indicated no association between early OA and grip strength. CONCLUSIONS The size of OPP may have a weak association with the diagnosis of early OA. CLINICAL RELEVANCE This study supports further exploration of the role of OPP in stabilizing the CMC joint, particularly with regard to minimizing joint subluxation. This may be clinically relevant to providers who treat patients with CMC OA early in the course of the disease, when nonsurgical treatment is the most relevant.
Collapse
|
8
|
Ohno K, Fujino K, Fujiwara K, Yokota A, Neo M. Sonographic evaluation of the abductor pollicis brevis muscle reflects muscle strength recovery after carpal tunnel release. J Med Ultrason (2001) 2022; 49:279-287. [PMID: 35239087 DOI: 10.1007/s10396-022-01195-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Accepted: 01/14/2022] [Indexed: 12/31/2022]
Abstract
PURPOSE This study aimed to examine the associations between sonographic measurements of the abductor pollicis brevis (APB), grip and pinch strength, and distal motor latency (DML) in patients with carpal tunnel syndrome (CTS) before and after surgery. METHODS We prospectively studied patients (46 hands) who underwent 1 year of postoperative follow-up after endoscopic carpal tunnel release. The patients underwent ultrasound (US) scans, grip and pinch strength assessment, a nerve conduction study, and patient-reported outcome measures (Carpal Tunnel Syndrome Instrument and Michigan Hand Outcomes Questionnaire) before and 1 year after surgery. The standardized response mean was calculated to compare the sensitivity of clinical changes in these measurements. RESULTS US measurements (thickness of the APB and the cross-sectional area of the APB) and muscle strength (grip strength, key pinch, and tip pinch) were greater, and DML was reduced after surgery compared with those before surgery (all P < 0.05). Patient-reported outcome measures also showed clinical improvement 1 year after surgery (P < 0.05). US measurements of the APB were significantly correlated with grip and pinch strength (all P < 0.05), but not with DML, before surgery and 1 year after surgery. The standardized response mean showed a large responsiveness for US measurements of the APB and patient-reported outcome measures. CONCLUSION US evaluation of the APB after CTS can complement the evaluation of grip and pinch strength in the clinical setting. Postoperative recovery of the APB leads to improved motor dysfunction in CTS. Therefore, US measurement of the APB could be a useful tool for evaluating motor function.
Collapse
Affiliation(s)
- Katsunori Ohno
- Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, 2-7 Daigaku-machi, Takatsuki, Osaka, 569-8686, Japan.
| | - Keitaro Fujino
- Department of Orthopedic Surgery, Hokusetsu General Hospital, 6-24 Kitayanagawa-cho, Takatsuki, Osaka, 569-8686, Japan
| | - Kenta Fujiwara
- Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, 2-7 Daigaku-machi, Takatsuki, Osaka, 569-8686, Japan
| | - Atsushi Yokota
- Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, 2-7 Daigaku-machi, Takatsuki, Osaka, 569-8686, Japan
| | - Masashi Neo
- Department of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, 2-7 Daigaku-machi, Takatsuki, Osaka, 569-8686, Japan
| |
Collapse
|
9
|
McGillivray MK, Haldane C, Doherty C, Berger MJ. Evaluation of muscle strength following peripheral nerve surgery: A scoping review. PM R 2022; 14:383-394. [PMID: 33751851 DOI: 10.1002/pmrj.12586] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 02/24/2021] [Accepted: 03/07/2021] [Indexed: 12/14/2022]
Abstract
Peripheral nerve injury (PNI) can result in devastating loss of function, often with poor long-term prognosis. Increased use of peripheral nerve surgical techniques (eg, nerve transfer, nerve grafting, and nerve repair) has resulted in improved muscle strength and other functional outcomes in patients with PNI. Muscle strength has largely been evaluated with the British Medical Research Council (MRC) scale. MRC is convenient to use in clinical settings, but more robust measures of muscle function are necessary to fully elucidate patient recovery. This scoping review aims to examine alternative instruments used to assess muscle function in studies of peripheral nerve surgery for PNI of the upper and lower limbs. A scoping review was conducted using Ovid MEDLINE, CINAHL, EMBASE, and PubMed databases in May and December of 2020, yielding a total of 20 studies pertaining to the review question. Studies pertaining to handheld dynamometry, grip and pinch dynamometry, Rotterdam Intrinsic Hand Myometers, isokinetic dynamometry, ultrasonography, and electromyography were reviewed. We provide a synopsis of each method and current clinical applications and discuss potential benefits, disadvantages, and areas of future research.
Collapse
Affiliation(s)
- Meghan K McGillivray
- Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | - Chloe Haldane
- Division of Physical Medicine and Rehabilitation, Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | - Christopher Doherty
- Division of Plastic Surgery, Department of Surgery, University of British Columbia, Vancouver, British Columbia, Canada
| | - Michael J Berger
- International Collaboration on Repair Discoveries, Vancouver, British Columbia, Canada
- Division of Physical Medicine & Rehabilitation, Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada
- School of Kinesiology, Faculty of Education, University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
10
|
Klein CS, Liu H, Zhao CN, Yang X. Quantitative ultrasound imaging of intrinsic hand muscles after traumatic cervical spinal cord injury. Spinal Cord 2022; 60:199-209. [PMID: 34172926 DOI: 10.1038/s41393-021-00653-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 06/04/2021] [Accepted: 06/08/2021] [Indexed: 02/06/2023]
Abstract
STUDY DESIGN This is a cross-sectional descriptive study. OBJECTIVES To quantify differences in hand muscle morphology between persons with cervical spinal cord injury (SCI) and uninjured adults. SETTING The study was performed at the Guangdong Work Injury Rehabilitation Hospital. METHODS We quantified hand muscle cross-sectional area (CSA), thickness, and echo intensity (EI) in 18 persons with subacute to chronic SCI and 23 controls using ultrasound imaging. RESULTS Mean SCI abductor pollicis brevis (APB), abductor digiti minimi (ADM), and first dorsal interosseous (FDI) CSA were ~26%, 43%, and 37% smaller than the control means, the deficit in the APB being less than the ADM (P < 0.05). Muscle thickness was also smaller after SCI, but deficits in ADM (31%) and FDI (20%) thickness were less than the CSA deficits (P < 0.05). In five SCI persons, APB CSA and/or opponens pollicis (OP) thickness were normal despite complete motor paralysis. Mean longitudinal image EI was 40% higher in the OP and 15% higher in the flexor pollicis brevis (FPB) after SCI (P < 0.05), suggesting denervation-induced infiltration of fat and fibrous tissues. OP EI was related to OP thickness (r = -0.6, P = 0.007, n = 18). Mean axial image EI was 10% higher in the APB and ADM after SCI (P < 0.05). There were no significant correlations between muscle morphological properties and clinical features in the SCI participants. CONCLUSION Our results indicate significant SCI atrophy and elevated EI that are muscle dependent.
Collapse
Affiliation(s)
- Cliff S Klein
- Guangdong Work Injury Rehabilitation Center, Guangzhou, China.
| | - Hui Liu
- Guangdong Work Injury Rehabilitation Center, Guangzhou, China
| | - Chen Ning Zhao
- Guangdong Work Injury Rehabilitation Center, Guangzhou, China
| | - Xinghua Yang
- Guangdong Work Injury Rehabilitation Center, Guangzhou, China
| |
Collapse
|
11
|
Bell M, Fernandez J, Florez R, Mirjalili A, Kim HK. 3-D Ultrasonographic Quantification of Hand and Calf Muscle Volume: Statistical Shape Modeling Approach. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:565-574. [PMID: 34998632 DOI: 10.1016/j.ultrasmedbio.2021.12.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 11/18/2021] [Accepted: 12/02/2021] [Indexed: 06/14/2023]
Abstract
Accurate acquisition and segmentation of muscles are essential in 3-D freehand ultrasonography (US) to estimate in vivo muscle volume, but the source of segmentation inaccuracy in shape variation has never been the focus. This study was aimed at investigating reliability of 3-D US in the acquisition and segmentation for muscle volume of two muscles of different sizes and in identifying a primary source of measurement difference. The lateral gastrocnemius and flexor pollicis brevis of 12 healthy adults were assessed using freehand 3-D US scans. The motion-tracking data of the probe were synchronized with the B-mode ultrasound scan to reconstruct 3-D muscle volume. Statistical shape modeling was used to provide a spatial segmentation volume difference that further explains the variation around segmentation repeatability. The absolute difference of the flexor pollicis brevis was 3.5 percentage points greater than that for the lateral gastrocnemius. The highest measurement differences were observed when for inter-acquirer analysis. Statistical shape modeling revealed that the primary segmentation volume differences were at the muscle ends and edges, where the muscle interfaces with the surrounding muscles. Three-dimensional US is a reliable tool in the clinical setting, but care must be taken to ensure that acquisition and segmentation are consistent, particularly in a small muscle that interfaces with tendons and other soft tissues.
Collapse
Affiliation(s)
- Matthew Bell
- Department of Anatomy and Medical Imaging, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Justin Fernandez
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand; Department of Engineering Science, Faculty of Engineering, University of Auckland, Auckland, New Zealand
| | - Ricardo Florez
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Ali Mirjalili
- Department of Anatomy and Medical Imaging, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Hyun Kyung Kim
- Kinesiology Department, Iowa State University, Ames, Iowa, USA.
| |
Collapse
|
12
|
Meza-Valderrama D, Sánchez-Rodríguez D, Perkisas S, Duran X, Bastijns S, Dávalos-Yerovi V, Da Costa E, Marco E. The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study. BMC Geriatr 2022; 22:137. [PMID: 35177006 PMCID: PMC8855585 DOI: 10.1186/s12877-022-02811-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Accepted: 02/02/2022] [Indexed: 12/16/2022] Open
Abstract
Background Given the potential benefits of introducing ultrasound in the clinical assessment of muscle disorders, this study aimed to assess the feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric clinical setting. Methods Cross-sectional pilot study in 25 participants (12 patients aged ≥ 70 years in an acute geriatric ward and 13 healthy volunteers aged 25–50 years), assessed by three raters. Muscle thickness measurement was estimated as the distance between the subcutaneous adipose tissue-muscle interface and muscle-bone interface of the radius at 30% proximal of the distance between the styloid process and distal insertion of the biceps brachii muscle of the dominant forearm. Examinations were repeated three times by each rater and intra- and inter-rater reliability was calculated. Feasibility analysis included consideration of technological, economic, legal, operational, and scheduling (TELOS) components. Results Mean muscle-thickness measurement difference between groups was 4.4 mm (95% confidence interval [CI] 2.4 mm to 6.3 mm], p < 0.001). Intra-rater reliability of muscle-thickness assessment was excellent, with intraclass correlation coefficient (ICC) of 0.947 (95%CI 0.902 to 0.974), 0.969 (95%CI 0.942 to 0.985), and 0.950 (95%CI 0.907 to 0.975) for observer A, B, and C, respectively. Inter-rater comparison showed good agreement (ICC of 0.873 [95%CI 0.73 to 0.94]). Four of the 17 TELOS components considered led to specific recommendations to improve the procedure’s feasibility in clinical practice. Conclusion Our findings suggest that US is a feasible tool to assess the thickness of the forearm muscles with good inter-rater and excellent intra-rater reliability in a sample of hospitalized geriatric patients, making it a promising option for use in clinical practice.
Collapse
Affiliation(s)
- Delky Meza-Valderrama
- Rehabilitation Research Group, Hospital Del Mar Medical Research Institute (IMIM), Carrer de Llull, 410, 08019, Barcelona, Catalonia, Spain. .,Physical Medicine and Rehabilitation Department, National Institute of Physical Medicine and Rehabilitation (INMFRE), Panama City, Panama. .,Physical Medicine and Rehabilitation Department, Caja de Seguro Social (C.S.S.), Panama City, Panama.
| | - Dolores Sánchez-Rodríguez
- Rehabilitation Research Group, Hospital Del Mar Medical Research Institute (IMIM), Carrer de Llull, 410, 08019, Barcelona, Catalonia, Spain.,Geriatrics Department, Brugmann University Hospital, Université Libre de Bruxelles, Brussels, Belgium.,WHO Collaborating Centre for Public Health Aspects of Musculo‑Skeletal Health and Aging, Division of Public Health, Epidemiology and Health Economics, University of Liège, Liège, Belgium
| | - Stany Perkisas
- University Center of Geriatrics, Antwerp University, Leopoldstraat 26, 2000, Antwerp, Belgium.,First Line and Interdisciplinary Care Medicine, ELIZA, University of Antwerp, 2650, Edegem, Belgium
| | - Xavi Duran
- Methodological and Biostatistical Advisory Service. Hospital del Mar Research Institute, Barcelona, Catalonia, Spain
| | - Sophie Bastijns
- University Center of Geriatrics, Antwerp University, Leopoldstraat 26, 2000, Antwerp, Belgium
| | - Vanesa Dávalos-Yerovi
- Rehabilitation Research Group, Hospital Del Mar Medical Research Institute (IMIM), Carrer de Llull, 410, 08019, Barcelona, Catalonia, Spain.,Physical Medicine and Rehabilitation Department, Vall d'Hebron University Hospital, Catalonia, Barcelona, Spain
| | - Elizabeth Da Costa
- Physical Medicine and Rehabilitation Department, Hospital Del Mar - Hospital de L´Esperança, Parc de Salut Mar, Barcelona, Catalonia, Spain
| | - Ester Marco
- Rehabilitation Research Group, Hospital Del Mar Medical Research Institute (IMIM), Carrer de Llull, 410, 08019, Barcelona, Catalonia, Spain.,Geriatric Department, Centre Fòrum-Hospital del Mar, Parc de Salut Mar, Barcelona, Catalonia, Spain.,School of Medicine, Universitat Autònoma de Barcelona, Barcelona, Catalonia, Spain.,School of Medicine, Universitat Internacional de Catalunya, Sant Cugat del Vallès, Barcelona, Catalonia, Spain
| |
Collapse
|
13
|
Swanson DC, Sponbeck JK, Swanson DA, Stevens CD, Allen SP, Mitchell UH, George JD, Johnson AW. Validity of ultrasound imaging for intrinsic foot muscle cross-sectional area measurements demonstrated by strong agreement with MRI. BMC Musculoskelet Disord 2022; 23:146. [PMID: 35164718 PMCID: PMC8842549 DOI: 10.1186/s12891-022-05090-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 02/02/2022] [Indexed: 11/10/2022] Open
Abstract
PURPOSE Intrinsic foot muscles maintain foot structural integrity and contribute to functional movement, posture and balance. Thus, assessing intrinsic foot muscle size and strength are important. Magnetic resonance imaging (MRI) has been shown to accurately image the individual muscles but is costly and time consuming. Ultrasound (US) imaging may provide an alternative that is less costly and more readily available. The purpose of this study was to investigate the validity and intratester reliability of US imaging in measuring intrinsic foot muscle size in comparison to MRI. METHODS US and MRI were employed to measure the intrinsic foot muscle size involving 35 participants (females = 13; males = 22). The scanned intrinsic foot muscles included the flexor hallucis brevis (FHB), abductor hallucis (ABDH), flexor digitorum brevis (FDB), quadratus plantae (QP) and abductor digiti minimi (ADM). Pearson product correlation (r), intraclass correlation coefficients (ICC), standard error of the measurement (SEm) and minimal detectable difference (MDD) were calculated. RESULTS High correlations were detected between the US and MRI cross-sectional area (CSA) measurements (r = .971 to 0.995). Test reliability was excellent for both MRI and US (ICC = 0.994 to 0.999). Limits of agreement between MRI and US measurements from ranged from 5.7 to 12.2% of muscle size. SEm values for US ranged from 0.026 to 0.044 cm2, while the SEm for MRI ranged from 0.018 to 0.023 cm2. MDD values for US ranged from 0.073 to 0.122 cm2, while MRI ranged from 0.045 to 0.064 cm2. CONCLUSIONS US appears to be a valid and reliable alternative to MRI when measuring intrinsic foot muscle CSA. While US is less costly and more readily available, the MRI results were shown to be slightly more precise.
Collapse
Affiliation(s)
- Dallin C Swanson
- Department of Exercise Sciences, Brigham Young University, 84602, Provo, UT, USA
| | - Joshua K Sponbeck
- Department of Exercise Sciences, Brigham Young University, 84602, Provo, UT, USA
| | - Derek A Swanson
- Department of Exercise Sciences, Brigham Young University, 84602, Provo, UT, USA
| | - Conner D Stevens
- Department of Exercise Sciences, Brigham Young University, 84602, Provo, UT, USA
| | - Steven P Allen
- Electrical and Computer Engineering, Ira A. Fulton College of Engineering, Brigham Young University, Provo, UT, USA
| | - Ulrike H Mitchell
- Department of Exercise Sciences, Brigham Young University, 84602, Provo, UT, USA
| | - James D George
- Department of Exercise Sciences, Brigham Young University, 84602, Provo, UT, USA
| | - Aaron Wayne Johnson
- Department of Exercise Sciences, Brigham Young University, 84602, Provo, UT, USA.
| |
Collapse
|
14
|
Normative Static Grip Strength of Saudi Arabia's Population and Influences of Numerous Factors on Grip Strength. Healthcare (Basel) 2021; 9:healthcare9121647. [PMID: 34946373 PMCID: PMC8701140 DOI: 10.3390/healthcare9121647] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 11/22/2021] [Accepted: 11/23/2021] [Indexed: 11/17/2022] Open
Abstract
Most daily tasks require exerting static grip strength which can be challenging for the elderly as their strength diminishes with age. Moreover, normative static grip strength data are important in ergonomics and clinical settings. The goal of this study is to present the gender, age-specific, hand-specific, and body-mass-index-specific handgrip strength reference of Saudi males and females in order to describe the population's occupational demand and to compare them with the international standards. The secondary objective is to investigate the effects of gender, age group, hand area, and body mass index on the grip strength. A sample of 297 (146 male and 151 female) volunteers aged between 18 and 70 with different occupations participated in the study. Grip strength data were collected using a Jamar dynamometer with standard test position, protocol, and instructions. The mean maximum voluntary grip strength values for males were 38.71 kg and 22.01 kg, respectively. There was a curvilinear relationship of grip strength to age; significant differences between genders, hand area, and some age groups; and a correlation to hand dimensions depending on the gender.
Collapse
|
15
|
Misirlioglu TO, Palamar D, Taskiran OO, Terlemez R, Akgun K. Relationship between ultrasonographic hand muscle thickness measurements and muscle strength following median or ulnar nerve reconstruction. Muscle Nerve 2020; 63:351-356. [PMID: 33244767 DOI: 10.1002/mus.27129] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 11/21/2020] [Accepted: 11/23/2020] [Indexed: 11/09/2022]
Abstract
INTRODUCTION The aim of this study was to assess the relationship between ultrasonographic hand muscle thickness measurements and hand muscle strength in patients who underwent median or ulnar nerve reconstruction. METHODS In this prospective, cross-sectional study, intrinsic hand muscle thicknesses were measured using ultrasound with a 4- to 13-MHz linear-array probe. Measurements of hand strength were performed using a dynamometer and a pinchmeter. RESULTS In the median nerve group (n = 11), a moderate correlation (r = 0.694; P = .018) was observed between lateral pinch strength and transverse thenar thickness. In the ulnar nerve group (n = 11), longitudinal thenar thickness below the flexor pollicis longus tendon was moderate to highly correlated with pinch and handgrip strengths (r = 0.726-0.893; P < .05); whole transverse thenar thickness was moderate to highly correlated with pinch strengths (r = 0.724-0.836; P < .05). DISCUSSION Sonographic measurements of intrinsic hand muscle thickness may be a useful tool for the assessment and follow-up of patients with median or ulnar nerve injury.
Collapse
Affiliation(s)
- Tugce Ozekli Misirlioglu
- Department of Physical Medicine and Rehabilitation, Istanbul University-Cerrahpasa, Cerrahpasa School of Medicine, Istanbul, Turkey
| | - Deniz Palamar
- Department of Physical Medicine and Rehabilitation, Istanbul University-Cerrahpasa, Cerrahpasa School of Medicine, Istanbul, Turkey
| | - Ozden Ozyemisci Taskiran
- Department of Physical Medicine and Rehabilitation, Koc University School of Medicine, Istanbul, Turkey
| | - Rana Terlemez
- Department of Physical Medicine and Rehabilitation, Istanbul University-Cerrahpasa, Cerrahpasa School of Medicine, Istanbul, Turkey
| | - Kenan Akgun
- Department of Physical Medicine and Rehabilitation, Istanbul University-Cerrahpasa, Cerrahpasa School of Medicine, Istanbul, Turkey
| |
Collapse
|
16
|
Trinidad-Fernández M, González-Molina F, Moya-Esteban A, Roldán-Jiménez C, González-Sánchez M, Cuesta-Vargas AI. Muscle activity and architecture as a predictor of hand-grip strength. Physiol Meas 2020; 41:075008. [PMID: 32585652 DOI: 10.1088/1361-6579/aba007] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND Grip strength is a powerful predictor of disability as well as a good indicator of physical activity. OBJECTIVES This study aimed to relate ultrasound (US) and electromyography (EMG) simultaneously to maximum hand-grip strength during an isometric contraction. APPROACH This is a cross-sectional study. Data acquisition was done with a dynamometer, US and EMG. Outcome variables included maximum strength during the hand-grip gesture, maximum muscle activity and change in muscle thickness. A non-linear regression analysis was performed to analyse the relationship between all outcome variables. MAIN RESULTS A total of 38 subjects (18 men and 20 women) participated in the study. The mean results for hand-grip strength were 25.50 (SD 6.55) kg of maximum strength, a change in muscle thickness of 1.83 (SD 0.75) mm and an EMG activity of 499.29 (SD 224.20) µV. Hand-grip strength had a high correlation with muscle thickness (R 2 = 0.61) and EMG activity (R 2 = 0.95). The correlation between maximum muscle activity and change in muscle thickness was R 2 = 0.83. SIGNIFICANCE The results of the present study demonstrate that this new method based on electromyographic activity and muscule architecture could be important in the development of the hand-grip test.
Collapse
Affiliation(s)
- Manuel Trinidad-Fernández
- Departamento de Fisioterapia, Instituto de Biomedicina de Málaga (IBIMA), Grupo de Clinimetría (F-14), Universidad de Málaga, Andalucía Tech, Facultad de Ciencias de la Salud, Málaga, Spain. Rehabilitation Sciences Research Department, Vrije Universiteit Brussel, Brussels, Belgium
| | | | | | | | | | | |
Collapse
|
17
|
Romero-Morales C, López-López S, Bravo-Aguilar M, Cerezo-Téllez E, Benito-de Pedro M, López López D, Lobo CC. Ultrasonography Comparison of the Plantar Fascia and Tibialis Anterior in People With and Without Lateral Ankle Sprain: A Case-Control Study. J Manipulative Physiol Ther 2020; 43:799-805. [PMID: 32709515 DOI: 10.1016/j.jmpt.2019.11.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2019] [Revised: 11/16/2019] [Accepted: 11/22/2019] [Indexed: 12/24/2022]
Abstract
OBJECTIVE The purpose of the present study was to evaluate the thickness of the plantar fascia (PF) at the insertion of the calcaneus and the midfoot and forefoot fascial locations, in addition to the thickness of the tibialis anterior, by ultrasound imaging in individuals with and without lateral ankle sprain (LAS). METHODS A sample of 44 participants was recruited and divided in 2 groups: 22 feet with a prior diagnosis of grade 1 or 2 LAS (case group) and 22 feet without this condition (healthy group). The thickness and cross-sectional area were evaluated by ultrasound imaging in both groups. RESULTS Ultrasound measurements of the PF at the calcaneus, midfoot, and forefoot showed statistically significant differences (P < .05), with a decrease in thickness in the LAS group relative to the healthy group. For the thickness and cross-sectional area of the tibialis anterior, no significant differences (P < .05) were observed between groups. CONCLUSION The thickness of the PF at the calcaneus, midfoot, and forefoot is reduced in individuals with LAS relative to the healthy group.
Collapse
Affiliation(s)
| | - Sergio López-López
- Faculty of Sports Sciences, European University of Madrid, Madrid, Spain
| | | | | | | | - Daniel López López
- Research, Health and Podiatry Group, Department of Health Sciences, Faculty of Nursing and Podiatry, University of Coruña, Ferrol, Spain
| | - César Calvo Lobo
- Faculty of Nursing, Physiotherapy and Podiatry, Complutence University of Madrid, Madrid, Spain
| |
Collapse
|
18
|
Shen S, Wang X, Fu Z. Value of Ultrasound-Guided Closed Reduction and Minimally Invasive Fixation in the Treatment of Metacarpal Fractures. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2019; 38:2659-2666. [PMID: 30790323 PMCID: PMC6850099 DOI: 10.1002/jum.14967] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 01/17/2019] [Accepted: 01/31/2019] [Indexed: 06/09/2023]
Abstract
OBJECTIVES To investigate the value of ultrasound-guided closed reduction and minimally invasive fixation in the treatment of metacarpal fractures. METHODS Twenty-four patients with acute metacarpal fractures were randomly divided into experimental and control groups, with 12 patients in each group. Ultrasound-guided closed reduction and fixation were performed in the experimental group, whereas C-arm fluoroscopy-assisted fixation was performed in the control group. Patients in both groups were followed to compare the treatment efficacy. RESULTS The success rates of ultrasound-guided closed reduction of fractures were 75.00% (9 of 12) in the experimental group and 83.33% (10 of 12) in the control group, and the difference was not statistically significant (χ2 = 0.253; P = .615) between the groups. The mean numbers of C-arm fluoroscopy-assisted procedures ± SD were 1.50 ± 0.67 times in the experimental group and 2.50 ± 0.80 in the control group, and the difference was statistically significant (t = -3.317; P = .003). The mean healing times of fractures were 5.47 ± 0.67 weeks in the experimental group and 5.73 ± 0.81 weeks in the control group; the excellence rates of total active motion were 83.33% (10 of 12) in the experimental group and 91.67% (11 of 12) in the control group; the mean grip strength values were 31.78 ± 3.13 kg in the experimental group and 33.43 ± 3.30 kg in the control group. There were no significant differences in those 3 parameters between the groups (P > .05 in each comparison). CONCLUSIONS Ultrasound-guided closed reduction and minimally invasive fixation is an effective treatment of metacarpal fractures and can reduce exposure to x-ray radiation.
Collapse
Affiliation(s)
- Suhong Shen
- Department of UltrasoundLuoyang Orthopedic‐Traumatological HospitalLuoyangChina
| | - Xiaohui Wang
- Hand Microsurgery UnitLuoyang Orthopedic Hospital of Henan Province (Orthopedic Hospital of Henan Province)LuoyangChina
| | - Zhuo Fu
- Department of UltrasoundLuoyang Orthopedic‐Traumatological HospitalLuoyangChina
| |
Collapse
|
19
|
Abraham A, Drory VE, Fainmesser Y, Algom AA, Lovblom LE, Bril V. Muscle thickness measured by ultrasound is reduced in neuromuscular disorders and correlates with clinical and electrophysiological findings. Muscle Nerve 2019; 60:687-692. [PMID: 31478199 DOI: 10.1002/mus.26693] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 08/28/2019] [Accepted: 08/28/2019] [Indexed: 12/11/2022]
Abstract
INTRODUCTION Nerve imaging has a limited role in axonal and muscle fiber loss. In this study, we sought to explore the utility of standardized muscle ultrasound (US) assessment in these clinical scenarios. METHODS We performed a prospective study from March to August 2018 of patients attending the neuromuscular clinic. All patients underwent clinical evaluation and standardized muscle thickness measurement by US in seven muscles. RESULTS The study cohort consisted of 114 participants, including patients with polyneuropathy, motor neuron disease, and myopathy. The smallest distal muscle thickness was found in patients with polyneuropathy, while the smallest proximal muscle thickness was found in patients with myopathy. Muscle thickness was strongly correlated with muscle strength (r 2 = 0.62), electrophysiological findings (r 2 : 0.44-0.55), and disability score (r 2 = 0.53). DISCUSSION Standardized muscle thickness measured by US shows diagnostic usefulness in a spectrum of neuromuscular disorders and correlates with clinical and electrophysiological findings.
Collapse
Affiliation(s)
- Alon Abraham
- Neuromuscular Diseases Unit, Department of Neurology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Vivian E Drory
- Neuromuscular Diseases Unit, Department of Neurology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Yaara Fainmesser
- Neuromuscular Diseases Unit, Department of Neurology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - Avi A Algom
- Neuromuscular Diseases Unit, Department of Neurology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - Leif E Lovblom
- Division of Endocrinology and Metabolism, Department of Medicine, Sinai Health System, and Lunenfeld Tanenbaum Research Institute, University of Toronto, Toronto, Canada
| | - Vera Bril
- Ellen and Martin Prosserman Centre for Neuromuscular Diseases, Division of Neurology, Department of Medicine, University Health Network, University of Toronto, Toronto, Canada.,Department for Research and Medical Consultations, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
20
|
Jung HS, Song KS, Jung HS, Yoon BI, Lee JS, Park MJ. Clinical Outcomes and Factors Influencing These Outcome Measures Resulting in Success After Arthroscopic Transosseous Triangular Fibrocartilage Complex Foveal Repair. Arthroscopy 2019; 35:2322-2330. [PMID: 31351810 DOI: 10.1016/j.arthro.2019.03.060] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Revised: 03/28/2019] [Accepted: 03/30/2019] [Indexed: 02/02/2023]
Abstract
PURPOSE To analyze postoperative outcomes after arthroscopic transosseous triangular fibrocartilage complex (TFCC) foveal repair and identify factors affecting the clinical outcomes. METHODS This study retrospectively enrolled patients who were treated for TFCC foveal tears by arthroscopic transosseous TFCC foveal repair. The diagnosis of TFCC foveal tear was made based on medical history, physical examination, and magnetic resonance imaging, with confirmation via arthroscopic examination. Outcome evaluation was completed at a minimum of 2 years postoperatively, and patients were classified into 2 groups according to the minimal clinically important difference of the Patient-Rated Wrist Evaluation. Various factors including age, sex, trauma history, body mass index, symptom duration, hand dominance, ulnar variance, subluxation of the distal radioulnar joint, preoperative pain score, and functional status, as well as the cross-sectional area (CSA) of the pronator quadratus (PQ) muscle, were retrospectively analyzed using both univariate and multivariate analyses. RESULTS During the study period, 42 patients were treated for TFCC foveal tears. The functional status significantly improved after surgery. Overall, 27 and 15 patients showed good and poor functional outcomes, respectively, which were assessed according to the minimal clinically important difference of the Patient-Rated Wrist Evaluation. On univariate analysis, clinical outcomes were better in male patients (P = .035), younger patients (P = .022), and those with higher CSAs of the PQ muscles (P < .001). However, on multivariable logistic regression analysis, only a higher CSA of the PQ muscle was identified as an independent prognostic factor affecting clinical outcome after TFCC foveal repair (P = .004). CONCLUSION Arthroscopic transosseous TFCC complex foveal repair led to satisfactory results. However, lower PQ muscle CSA on magnetic resonance imaging was the most independent prognostic factor negatively affecting clinical outcomes. LEVEL OF EVIDENCE Level III, retrospective comparative study.
Collapse
Affiliation(s)
- Hyoung Seok Jung
- Department of Orthopedic Surgery, Hospital of Chung-Ang University of Medicine, Seoul, Korea
| | - Kwang-Sup Song
- Department of Orthopedic Surgery, Hospital of Chung-Ang University of Medicine, Seoul, Korea
| | - Han Sol Jung
- Department of Orthopedic Surgery, Hospital of Chung-Ang University of Medicine, Seoul, Korea
| | - Byung Il Yoon
- Department of Orthopedic Surgery, Hospital of Chung-Ang University of Medicine, Seoul, Korea
| | - Jae-Sung Lee
- Department of Orthopedic Surgery, Hospital of Chung-Ang University of Medicine, Seoul, Korea.
| | - Min Jong Park
- Department of Orthopedic Surgery, Samsung Medical Center, SungKyunKwan University School of Medicine, Seoul, Korea
| |
Collapse
|
21
|
Romero-Morales C, Martín-Llantino PJ, Calvo-Lobo C, López-López D, Sánchez-Gómez R, De-La-Cruz-Torres B, Rodríguez-Sanz D. Ultrasonography Features of the Plantar Fascia Complex in Patients with Chronic Non-Insertional Achilles Tendinopathy: A Case-Control Study. SENSORS 2019; 19:s19092052. [PMID: 31052554 PMCID: PMC6539056 DOI: 10.3390/s19092052] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Revised: 04/25/2019] [Accepted: 04/30/2019] [Indexed: 12/28/2022]
Abstract
Purpose: The goal of the present study was to assess, by ultrasound imaging (USI), the thickness of the plantar fascia (PF) at the insertion of the calcaneus, mid and forefoot fascial locations, and the calcaneal fat pad (CFP) in patients with Achilles tendinopathy (AT). Methods: An observational case-control study. A total sample of 143 individuals from 18 to 55 years was evaluated by USI in the study. The sample was divided into two groups: A group composed of the chronic non-insertional AT (n = 71) and B group comprised by healthy subjects (n = 72). The PF thicknesses at insertion on the calcaneus, midfoot, rearfoot and CFP were evaluated by USI. Results: the CFP and PF at the calcaneus thickness showed statistically significant differences (P < 0.01) with a decrease for the tendinopathy group with respect to the control group. For the PF midfoot and forefoot thickness, no significant differences (P > 0.05) were observed between groups. Conclusion: The thickness of the PF at the insertion and the CPF is reduced in patients with AT measured by USI.
Collapse
Affiliation(s)
- Carlos Romero-Morales
- Faculty of Sport Sciences, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain.
| | | | - César Calvo-Lobo
- Faculty of Health Sciences, Institute of Biomedicine (IBIOMED), Universidad de León, 24401 Ponferrada, Spain.
| | - Daniel López-López
- Research, Health and Podiatry Unit, Department of Health Sciences, Faculty of Nursing and Podiatry, Universidade da Coruña, 15403 Ferrol, Spain.
| | - Rubén Sánchez-Gómez
- Faculty of Sport Sciences, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain.
- Facultad de Enfermería, Fisioterapia y Podología, Universidad Complutense de Madrid, 28040 Madrid, Spain.
| | | | - David Rodríguez-Sanz
- Faculty of Sport Sciences, Universidad Europea de Madrid, Villaviciosa de Odón, 28670 Madrid, Spain.
- Facultad de Enfermería, Fisioterapia y Podología, Universidad Complutense de Madrid, 28040 Madrid, Spain.
| |
Collapse
|
22
|
Fujino K, Ohno K, Fujiwara K, Yokota A, Neo M. Sonographic morphometry of abductor pollicis brevis: can direct contact yield images comparable with those obtained by the water bath technique? J Med Ultrason (2001) 2019; 46:489-495. [PMID: 30989442 DOI: 10.1007/s10396-019-00945-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2018] [Accepted: 03/19/2019] [Indexed: 10/27/2022]
Abstract
PURPOSE This study sought to compare ultrasound-guided measurements of the abductor pollicis brevis (APB) using the water bath technique (WBT) and the direct contact method (DM) and investigate whether the DM can reproduce the measurements that would be obtained with a non-contact method, such as the WBT. METHODS The APB muscles of 80 hands (40 healthy adults) were measured. The WBT was performed in a plastic container filled with water. The probe was placed adjacent to the skin surface without contact. In the DM, sonographic images were obtained with the probe and skin separated by sufficient transmission gel. The muscle thickness and cross-sectional area (CSA) were calculated with both methods. All subjects were examined three times by two examiners to estimate the inter- and intra-observer reliability. Bland-Altman analysis was performed to examine the agreement between the methods. RESULTS No significant differences in the thickness or CSA of the APB were found. The interclass correlation coefficients for the WBT and DM showed almost perfect intra- and inter-observer reliability (range 0.87-0.94). There was no systematic bias between the techniques in the Bland-Altman analysis. CONCLUSION Similar to the WBT, the DM provides measurements of the APB thickness and CSA without causing morphometric changes.
Collapse
Affiliation(s)
- Keitaro Fujino
- Department of Orthopedic Surgery, Osaka Medical College, 2-7 Daigakumachi, Takatsuki, 569-8686, Osaka, Japan
| | - Katsunori Ohno
- Department of Orthopedic Surgery, Osaka Medical College, 2-7 Daigakumachi, Takatsuki, 569-8686, Osaka, Japan.
| | - Kenta Fujiwara
- Department of Orthopedic Surgery, Osaka Medical College, 2-7 Daigakumachi, Takatsuki, 569-8686, Osaka, Japan
| | - Atsushi Yokota
- Department of Orthopedic Surgery, Osaka Medical College, 2-7 Daigakumachi, Takatsuki, 569-8686, Osaka, Japan
| | - Masashi Neo
- Department of Orthopedic Surgery, Osaka Medical College, 2-7 Daigakumachi, Takatsuki, 569-8686, Osaka, Japan
| |
Collapse
|
23
|
Romero-Morales C, Martín-Llantino PJ, Calvo-Lobo C, Sánchez-Gómez R, López-López D, Pareja-Galeano H, Rodríguez-Sanz D. Ultrasound evaluation of extrinsic foot muscles in patients with chronic non-insertional Achilles tendinopathy: A case-control study. Phys Ther Sport 2019; 37:44-48. [PMID: 30844628 DOI: 10.1016/j.ptsp.2019.02.006] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2019] [Revised: 02/18/2019] [Accepted: 02/19/2019] [Indexed: 12/26/2022]
Abstract
AIM The purpose of the present study was to compare and quantify with ultrasound imaging (USI) the extensor digitorum longus (EDL), tibialis anterior (TA) and peroneus muscles (PER) muscle thickness and cross-sectional area (CSA) between chronic non-insertional Achilles tendinopathy (AT) and healthy subjects. METHODS a sample of 143 individuals was recruited and divided in two groups: chronic non-insertional AT group (n = 71) and a healthy group (n = 72). The thickness and CSA were assessment by USI for EDL, TA and PER muscles in both groups. RESULTS The thickness evaluation for the TA muscle increased showing statistically significant differences (P = 0.018) as well as for the thickness of the PER muscles significant differences (P = 0.001) were observed in favor the tendinopathy group. The CSA measurements showed statistically significant differences for a decrease in EDL (P = 0.000), TA (P = 0.001) and PER muscles (P = 0.011) for the tendinopathy group with respect to the control group. CONCLUSIONS The CSA of the EDL, TA and PER muscles is reduced in participants with chronic non-insertional AT. The thickness for TA muscle is increased as well as a decrease of PER muscles thickness is presented for the AT group with respect to the control group.
Collapse
Affiliation(s)
- Carlos Romero-Morales
- Faculty of Sports Sciences, Universidad Europea de Madrid, Villaviciosa de Odón, Madrid, Spain
| | | | - César Calvo-Lobo
- Nursing and Physical Therapy Department, Faculty of Health Sciences, Insitute of Biomedicine (IBIOMED), Universidad de León, Ponferrada, Spain
| | - Rubén Sánchez-Gómez
- Faculty of Sports Sciences, Universidad Europea de Madrid, Villaviciosa de Odón, Madrid, Spain; Facultad de Enfermería, Fisioterapia y Podología. Universidad Complutense de Madrid, Madrid, Spain
| | - Daniel López-López
- Research, Health and Podiatry Unit, Department of Health Sciences, Faculty of Nursing and Podiatry, Universidade da Coruña, Ferrol, Spain.
| | - Helios Pareja-Galeano
- Faculty of Sports Sciences, Universidad Europea de Madrid, Villaviciosa de Odón, Madrid, Spain
| | - David Rodríguez-Sanz
- Faculty of Sports Sciences, Universidad Europea de Madrid, Villaviciosa de Odón, Madrid, Spain; Facultad de Enfermería, Fisioterapia y Podología. Universidad Complutense de Madrid, Madrid, Spain
| |
Collapse
|
24
|
Bertelli J, Tavares K. Little finger abduction and adduction testing in ulnar nerve lesions. HAND SURGERY & REHABILITATION 2018; 37:368-371. [DOI: 10.1016/j.hansur.2018.09.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2018] [Revised: 09/09/2018] [Accepted: 09/26/2018] [Indexed: 11/15/2022]
|
25
|
Sconfienza LM, Albano D, Allen G, Bazzocchi A, Bignotti B, Chianca V, Facal de Castro F, Drakonaki EE, Gallardo E, Gielen J, Klauser AS, Martinoli C, Mauri G, McNally E, Messina C, Mirón Mombiela R, Orlandi D, Plagou A, Posadzy M, de la Puente R, Reijnierse M, Rossi F, Rutkauskas S, Snoj Z, Vucetic J, Wilson D, Tagliafico AS. Clinical indications for musculoskeletal ultrasound updated in 2017 by European Society of Musculoskeletal Radiology (ESSR) consensus. Eur Radiol 2018; 28:5338-5351. [PMID: 29876703 DOI: 10.1007/s00330-018-5474-3] [Citation(s) in RCA: 159] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Revised: 04/02/2018] [Accepted: 04/11/2018] [Indexed: 12/11/2022]
Abstract
OBJECTIVES To update the 2012 European Society of Musculoskeletal Radiology (ESSR) clinical consensus guidelines for musculoskeletal ultrasound referral in Europe. METHODS Twenty-one musculoskeletal imaging experts from the ESSR participated in a consensus study based on a Delphic process. Two independent (non-voting) authors facilitated the procedure and resolved doubtful issues. Updated musculoskeletal ultrasound literature up to July 2017 was scored for shoulder, elbow, wrist/hand, hip, knee, and ankle/foot. Scoring of ultrasound elastography was included. The strength of the recommendation and level of evidence was scored by consensus greater than 67% or considered uncertain when the consensus was consensus less than 67%. RESULTS A total of 123 new papers were reviewed. No evidence change was found regarding the shoulder. There were no new relevant articles for the shoulder, 10 new articles for the elbow, 28 for the hand/wrist, 3 for the hip, 7 for the knee, and 4 for the ankle/foot. Four new evidence levels of A were determined, one for the hip (gluteal tendons tears), one for the knee (meniscal cysts), one for the ankle (ankle joint instability), and one for the foot (plantar plate tear). There was no level A evidence for elastography, although for Achilles tendinopathy and lateral epicondylitis evidence level was B with grade 3 indication. CONCLUSIONS Four new areas of level A evidence were included in the guidelines. Elastography did not reach level A evidence. Whilst ultrasound is of increasing importance in musculoskeletal medical practice, the evidence for elastography remains moderate. KEY POINTS • Evidence and expert consensus shows an increase of musculoskeletal ultrasound indications. • Four new A evidence levels were found for the hip, knee, ankle, and foot. • There was no level A evidence for elastography.
Collapse
Affiliation(s)
- Luca Maria Sconfienza
- Unità Operativa di Radiologia Diagnostica ed Interventistica, IRCCS Istituto Ortopedico Galeazzi, Via Riccardo Galeazzi 4, 20161, Milano, Italy.
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Mangiagalli 31, 20133, Milano, Italy.
| | - Domenico Albano
- Department of Radiology, Di.Bi.Med., University of Palermo, Via del Vespro 127, 90127, Palermo, Italy
| | - Georgina Allen
- Department of Radiology, St Lukes Radiology Oxford Ltd, Oxford, UK
| | - Alberto Bazzocchi
- Diagnostic and Interventional Radiology, "Rizzoli" Orthopaedic Institute, Bologna, Italy
| | - Bianca Bignotti
- Department of Health Sciences (DISSAL), University of Genoa, Via Pastore 1, 16132, Genova, Italy
| | - Vito Chianca
- Department of Advanced Biomedical Sciences, Università degli studi Federico II, via Pansini 5, 80131, Napoli, Italy
| | | | | | - Elena Gallardo
- Department of Radiology, University Hospital Marqués de Valdecilla, University of Cantabria, Santander, Spain
| | - Jan Gielen
- Radiology and S.P.O.R.T.S. Department, Antwerp University and Antwerp University Hospital, Wilrijkstraat 10, 2650, Edegem, Antwerp, Belgium
| | - Andrea Sabine Klauser
- Department of Radiology, Medical University Innsbruck, Section Rheumatology and Sports Imaging, Innsbruck, Austria
| | - Carlo Martinoli
- Department of Health Sciences (DISSAL), University of Genoa, Via Pastore 1, 16132, Genova, Italy
- Ospedale Policlinico San Martino, Genova, Italy
| | - Giovanni Mauri
- Division of Interventional Radiology, European Institute of Oncology, via Ripamonti 435, 20141, Milano, Italy
| | | | - Carmelo Messina
- Unità Operativa di Radiologia Diagnostica ed Interventistica, IRCCS Istituto Ortopedico Galeazzi, Via Riccardo Galeazzi 4, 20161, Milano, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Mangiagalli 31, 20133, Milano, Italy
| | - Rebeca Mirón Mombiela
- Hospital General Universitario de Valencia, Ave. Tres Cruces 2, 46014, Valencia, Spain
- Department of Physiology, Universidad de Valencia/INCLIVA, Avenida Blasco Ibañez 15, 46010, Valencia, Spain
| | - Davide Orlandi
- S.C. Diagnostica per Immagini e Ecografia Interventistica, Ospedale Evangelico Internazionale, Corso Solferino 1A, 16122, Genova, Italy
| | - Athena Plagou
- Department of Radiology, Private Institution of Ultrasonography, Athens, Greece
| | - Magdalena Posadzy
- Department of Radiology, W. Dega Orthopaedic and Rehabilitation University Hospital of Karol Marcinkowski University of Medical Sciences, Poznan, Poland
| | | | - Monique Reijnierse
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Federica Rossi
- Department of Health Sciences (DISSAL), University of Genoa, Via Pastore 1, 16132, Genova, Italy
| | - Saulius Rutkauskas
- Institute of Sport Science and Innovation, Lithuanian Sports University, Kaunas, Lithuania
| | - Ziga Snoj
- Ljubljana University Medical Centre, Clinical Institute of Radiology, Ljubljana, Slovenia
| | - Jelena Vucetic
- Hospital General Universitario de Valencia, Ave. Tres Cruces 2, 46014, Valencia, Spain
- Department of Physiology, Universidad de Valencia/INCLIVA, Avenida Blasco Ibañez 15, 46010, Valencia, Spain
| | - David Wilson
- Department of Radiology, St Lukes Radiology Oxford Ltd, Oxford, UK
| | - Alberto Stefano Tagliafico
- Department of Health Sciences (DISSAL), University of Genoa, Via Pastore 1, 16132, Genova, Italy
- Ospedale Policlinico San Martino, Genova, Italy
| |
Collapse
|
26
|
Morales CR, Polo JA, Sanz DR, López DL, González SV, Buría JLA, Lobo CC. Ultrasonography features of abdominal perimuscular connective tissue in elite and amateur basketball players: an observational study. Rev Assoc Med Bras (1992) 2018; 64:936-941. [DOI: 10.1590/1806-9282.64.10.936] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2018] [Accepted: 02/16/2018] [Indexed: 11/22/2022] Open
Abstract
SUMMARY The purpose of this study was to assess and compare with rehabilitative ultrasound imaging (RUSI) the perimuscular connective tissue (PMCT) and interrecti distance (IRD) between elite and amateur basketball players. A sample of 22 healthy basketball players was included and divided into two groups: elite basketball players from Spanish 1st division (n = 11) and amateur basketball players from an entertainment Spanish division (n = 11). Ultrasound images of the external oblique (EO), internal oblique (IO), transversus abdominis (TrAb), rectus anterior (RA) and IRD PMCT were measured and analysed by the ImageJ software. Measurements of abdominal wall muscles PMCT present statistically differences (P < .05) for an increase of perimuscular connective tissue of external oblique (PMCTEO), perimuscular connective tissue of transversus abdominis (PMCTTA) of the left side and an increase of PMCTEO on the right side in favor of the elite group. Rather, the study showed statistically differences (P < .05) for a decrease of perimuscular connective tissue between the internal oblique and transversus abdominis (PMCTIO-TA), and a decrease in PMCT total summation of the left side with elite group in respect to amateur group. This study reported an increase of left PMCTEO, left PMCTTAA, right PMCTEO as well as a decrease of left PMCTIO-TA and in PMCT total summation on the left side.
Collapse
|
27
|
Wang X, Wang Q, Zhang C, Shen S, Li W. [Ultrasound-guided percutaneous Herbert screw for the treatment of fresh nondisplaced carpal scaphoid fracture]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2018; 32:989-992. [PMID: 30238723 DOI: 10.7507/1002-1892.201802023] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To explore the effectiveness of ultrasound-guided percutaneous Herbert screw for the treatment of fresh nondisplaced carpal scaphoid fracture. Methods Between May 2013 and August 2015, 15 patients with fresh nondisplaced carpal scaphoid fractures (Krimmer type A2) were treated with ultrasound-guided Herbert screw fixation. There were 12 males and 3 females with an average age of 33.4 years (range, 18-51 years). The causes of injury included 9 cases of falls, 3 cases of training injuries, and 3 cases of machine injuries. The interval from injury to surgery was 2-15 days (mean, 5 days). No other complication was found. The operation time, intraoperative blood loss, intraoperative fluoroscopy times, and the fracture healing time were recorded. The wrist function was assessed by the modified Mayo wrist score standard. Results The operation time was 28-53 minutes (mean, 33.9 minutes); the intraoperative blood loss was 5-30 mL (mean, 10.5 mL); the intraoperative fluoroscopy was 2-6 times (mean, 2.6 times). All 15 patients were followed up 6-18 months (mean, 10.5 months). One patient developed pain and soreness in the skin of the nail entrance, and gradually relieved after fumigation. No complication such as infection occurred. All fractures healed clinically, and the healing time was 8-16 weeks (mean, 11.6 weeks). At last follow-up, the modified Mayo wrist score was 76-99 (mean, 92.5). Among them, 12 cases were excellent, 2 cases were good, and 1 case was fair, and the excellent and good rate was 93.3%. Conclusion Ultrasound-guided fixation with Herbert screw is a reliable treatment method for fresh nondisplaced carpal scaphoid fractures with small invasion, less bleeding, and small radiation damage.
Collapse
Affiliation(s)
- Xiaohui Wang
- Department of Hand Microsurgery, Luoyang Orthopedic Hospital of Henan Province (Orthopedic Hospital of Henan Province), Luoyang Henan, 471002,
| | - Qingfeng Wang
- Department of Hand Microsurgery, Luoyang Orthopedic Hospital of Henan Province (Orthopedic Hospital of Henan Province), Luoyang Henan, 471002, P.R.China
| | - Caili Zhang
- Department of Hand Microsurgery, Luoyang Orthopedic Hospital of Henan Province (Orthopedic Hospital of Henan Province), Luoyang Henan, 471002, P.R.China
| | - Suhong Shen
- Department of Hand Microsurgery, Luoyang Orthopedic Hospital of Henan Province (Orthopedic Hospital of Henan Province), Luoyang Henan, 471002, P.R.China
| | - Wuyin Li
- Department of Hand Microsurgery, Luoyang Orthopedic Hospital of Henan Province (Orthopedic Hospital of Henan Province), Luoyang Henan, 471002, P.R.China
| |
Collapse
|
28
|
Long-term outcomes in patients with ulnar neuropathy at the elbow treated according to the presumed aetiology. Clin Neurophysiol 2018; 129:1763-1769. [DOI: 10.1016/j.clinph.2018.04.753] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Revised: 04/19/2018] [Accepted: 04/29/2018] [Indexed: 01/15/2023]
|
29
|
Rehabilitative Ultrasound Imaging Features of the Abdominal Wall Muscles in Elite and Amateur Basketball Players. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8050809] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
30
|
Omejec G, Podnar S. Neurologic examination and instrument-based measurements in the evaluation of ulnar neuropathy at the elbow. Muscle Nerve 2018; 57:951-957. [DOI: 10.1002/mus.26046] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2017] [Revised: 12/11/2017] [Accepted: 12/15/2017] [Indexed: 11/10/2022]
Affiliation(s)
- Gregor Omejec
- Institute of Clinical Neurophysiology; University Medical Center Ljubljana, Zaloška cesta 7, SI-1525 Ljubljana; Slovenia
| | - Simon Podnar
- Institute of Clinical Neurophysiology; University Medical Center Ljubljana, Zaloška cesta 7, SI-1525 Ljubljana; Slovenia
| |
Collapse
|
31
|
Misirlioglu TO, Ozyemisci Taskiran O. Reliability of sonographic muscle thickness measurements of the thenar and hypothenar muscles. Muscle Nerve 2017; 57:E14-E17. [PMID: 28662294 DOI: 10.1002/mus.25735] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2017] [Revised: 06/12/2017] [Accepted: 06/24/2017] [Indexed: 12/13/2022]
Abstract
Introduction This study was undertaken to assess the intra- and interrater reliability of sonographic thickness measurements of the thenar and hypothenar muscles. METHODS The thickness of the thenar and hypothenar muscles of both hands of 15 volunteers (7 male, 8 female) were evaluated with a 4-13-MHz linear probe by 2 examiners who were blinded to each other's measurements. Interrater reliability was then evaluated. To assess intrarater reliability, the first examiner also performed a second measurement after an interval of at least 1 day. RESULTS Mean age of the subjects was 31.1 ± 9.0 years. Test-retest reliability showed excellent intrarater reliability (intraclass correlation coefficient range: 0.889-0.963) and substantial to excellent results for interrater reliability (intraclass correlation coefficient range: 0.692-0.937). DISCUSSION We found that ultrasound is a reliable method for thickness measurements of the thenar and hypothenar muscles. Muscle Nerve 57: E14-E17, 2018.
Collapse
Affiliation(s)
- Tugce Ozekli Misirlioglu
- Department of Physical Medicine and Rehabilitation, Koc University School of Medicine, Istanbul, Turkey
| | - Ozden Ozyemisci Taskiran
- Department of Physical Medicine and Rehabilitation, Koc University School of Medicine, Istanbul, Turkey
| |
Collapse
|
32
|
Ultrasonography Comparison of Peroneus Muscle Cross-sectional Area in Subjects With or Without Lateral Ankle Sprains. J Manipulative Physiol Ther 2016; 39:635-644. [DOI: 10.1016/j.jmpt.2016.09.001] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2015] [Revised: 11/21/2015] [Accepted: 02/10/2016] [Indexed: 11/19/2022]
|
33
|
Boban M, Barisic M, Persic V, Zekanovic D, Medved I, Zulj M, Vcev A. Muscle strength differ between patients with diabetes and controls following heart surgery. J Diabetes Complications 2016; 30:1287-92. [PMID: 27368124 DOI: 10.1016/j.jdiacomp.2016.06.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2016] [Revised: 05/20/2016] [Accepted: 06/04/2016] [Indexed: 01/16/2023]
Abstract
BACKGROUND The aim of our study was to analyze muscle strength in patients with recent surgical treatment for ischemic and combined ischemic-valvular heart disease, based on existence of diabetes mellitus. Connections existing between muscle strength and patient characteristics or conventional diagnostic tests were analyzed as well. METHODS Study prospectively included consecutive patients scheduled for cardiovascular rehabilitation 0-3months after heart surgery. Diagnostics covered drug utilization, anthropometrics, demographics, echocardiography, conventional laboratory, echocardiography, bioelectrical impedance analysis (BIA), and hand grip test (HGT). HGT was analyzed for dominant hand. RESULTS Patients with diabetes had significantly weaker muscle strength on HGT than controls; 29.4±12.2kg vs. 38.2±14.7kg (p=0.029), respectively. ROC analysis for HGT and existence of diabetes mellitus were significant; ≤40kg had sensitivity of 89.7% (95%CI: 72.6-97.8), specificity 43.7% (31.9-56.0); AUC 0.669 (0.568-0.760); p=0.002. HGT significantly correlated with hematocrit (Rho CC=0.247; p=0.013), whilst other laboratory or echocardiographic parameters were insignificant (all p>0.05). HGT also correlated with body weight (Rho CC=0.510; p<0.001); height (Rho CC=0.632; p<0.001); waist circumference (Rho CC=0.388; p<0.001); waist-to-hip ratio (Rho CC=0.274; p=0.006) and BIA (Rho CC=-0.412; p<0.001). CONCLUSIONS In postoperative recovery of patients with diabetes, muscle strength assessed by HGT is decreased and in relation with nutritional status. Clinically resourceful connections of HGT were also found to hematocrit and utilization of loop diuretics.
Collapse
Affiliation(s)
- Marko Boban
- Department of Cardiology, University Hospital "Thalassotherapia Opatija", Medical Faculty University of Rijeka, Croatia; Department of Internal Medicine, Medical Faculty "J.J. Strossmayer" University of Osijek, Croatia.
| | - Mijana Barisic
- Department of Cardiology, University Hospital "Thalassotherapia Opatija", Medical Faculty University of Rijeka, Croatia
| | - Viktor Persic
- Department of Cardiology, University Hospital "Thalassotherapia Opatija", Medical Faculty University of Rijeka, Croatia; Department of Internal Medicine, Medical Faculty "J.J. Strossmayer" University of Osijek, Croatia
| | | | - Igor Medved
- Department of Cardiac Surgery, Medical Faculty University of Rijeka, University Hospital Centre "Rijeka", Croatia
| | - Marinko Zulj
- Department of Internal Medicine, Medical Faculty "J.J. Strossmayer" University of Osijek, Croatia
| | - Aleskandar Vcev
- Department of Internal Medicine, Medical Faculty "J.J. Strossmayer" University of Osijek, Croatia
| |
Collapse
|
34
|
Evaluation of extensor digitorum brevis thickness in healthy subjects: A comparative analysis of nerve conduction studies and ultrasound scans. Clin Neurophysiol 2016; 127:1664-1668. [DOI: 10.1016/j.clinph.2015.07.025] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2015] [Revised: 07/08/2015] [Accepted: 07/17/2015] [Indexed: 12/14/2022]
|
35
|
Bulstra LF, Hundepool CA, Friedrich PF, Nijhuis THJ, Bishop AT, Shin AY. Motor Nerve Recovery in a Rabbit Model: Description and Validation of a Noninvasive Ultrasound Technique. J Hand Surg Am 2016; 41:27-33. [PMID: 26710731 DOI: 10.1016/j.jhsa.2015.11.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2015] [Revised: 11/01/2015] [Accepted: 11/01/2015] [Indexed: 02/02/2023]
Abstract
PURPOSE To develop and validate a noninvasive ultrasound technique for the longitudinal analysis of functional recovery after segmental peroneal nerve reconstruction in a rabbit model. METHODS Twelve male New Zealand White rabbits underwent a 1-cm peroneal nerve autograft reconstruction. Ultrasound measurements were performed before surgery and at 1, 2, 4, 8, 12, and 16 weeks postoperatively. All rabbits were managed with manual restraint for the ultrasound procedure, avoiding the risks of anesthetics. At 12 and 16 weeks, we evaluated functional recovery using compound muscle action potential, isometric tetanic force measurements, wet muscle weight, and nerve histomorphometry. Data were compared with ultrasound measurements by calculating the Pearson correlation coefficient. We determined intra-rater and inter-rater reliability of the ultrasound measurements. RESULTS Ultrasound demonstrated good correlation with isometric tetanic force measurements and wet muscle weight, good correlation with nerve histomorphometry, and moderate correlation with compound muscle action potential. Both intra-rater and inter-rater reliability of the ultrasound technique was excellent. CONCLUSIONS Ultrasound analysis of the tibialis anterior muscle provided a reliable method for analysis of functional recovery in a rabbit peroneal nerve reconstruction model. The noninvasive nature allowed for longitudinal follow-up within the same animal and measurement of early recovery without the use of anesthesia. CLINICAL RELEVANCE Application of this noninvasive technique can reduce the variability and sample size necessary in peripheral nerve reconstruction studies and may provide an ideal tool for comparative studies in larger animal models.
Collapse
Affiliation(s)
- Liselotte F Bulstra
- Department of Orthopedic Surgery, Microvascular Research Laboratory, Mayo Clinic, Rochester, MN; Department of Plastic, Reconstructive and Hand Surgery, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Caroline A Hundepool
- Department of Orthopedic Surgery, Microvascular Research Laboratory, Mayo Clinic, Rochester, MN; Department of Plastic, Reconstructive and Hand Surgery, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Patricia F Friedrich
- Department of Orthopedic Surgery, Microvascular Research Laboratory, Mayo Clinic, Rochester, MN
| | - Tim H J Nijhuis
- Department of Plastic, Reconstructive and Hand Surgery, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Allen T Bishop
- Department of Orthopedic Surgery, Microvascular Research Laboratory, Mayo Clinic, Rochester, MN
| | - Alexander Y Shin
- Department of Orthopedic Surgery, Microvascular Research Laboratory, Mayo Clinic, Rochester, MN.
| |
Collapse
|