1
|
Fonseca ICF, Pais ML, Rodrigues FMS, Sereno J, Castelo-Branco M, Cavadas C, Pereira MM, Abrunhosa AJ. Improved Chemical and Radiochemical Synthesis of Neuropeptide Y Y 2 Receptor Antagonist N-Methyl-JNJ-31020028 and Preclinical Positron Emission Tomography Studies. Pharmaceuticals (Basel) 2024; 17:474. [PMID: 38675435 PMCID: PMC11053772 DOI: 10.3390/ph17040474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 03/30/2024] [Accepted: 04/03/2024] [Indexed: 04/28/2024] Open
Abstract
Neuropeptide Y (NPY) is one of the most abundant peptides in the central nervous system of mammals and is involved in several physiological processes through NPY Y1, Y2, Y4 and Y5 receptors. Of those, the Y2 receptor has particular relevance for its autoreceptor role in inhibiting the release of NPY and other neurotransmitters and for its involvement in relevant mechanisms such as feeding behaviour, cognitive processes, emotion regulation, circadian rhythms and disorders such as epilepsy and cancer. PET imaging of the Y2 receptor can provide a valuable platform to understand this receptor's functional role and evaluate its potential as a therapeutic target. In this work, we set out to refine the chemical and radiochemical synthesis of the Y2 receptor antagonist N-[11C]Me-JNJ31020028 for in vivo PET imaging studies. The non-radioactive reference compound, N-Me-JNJ-31020028, was synthesised through batch synthesis and continuous flow methodology, with 43% and 92% yields, respectively. N-[11C]Me-JNJ-31020028 was obtained with a radiochemical purity > 99%, RCY of 31% and molar activity of 156 GBq/μmol. PET imaging clearly showed the tracer's biodistribution in several areas of the mouse brain and gut where Y2 receptors are known to be expressed.
Collapse
Affiliation(s)
- Inês C. F. Fonseca
- CIBIT/ICNAS, Institute for Nuclear Sciences Applied to Health, University of Coimbra, 3000-548 Coimbra, Portugal; (I.C.F.F.); (M.L.P.); (J.S.); (M.C.-B.)
- Faculty of Pharmacy, University of Coimbra, 3000-548 Coimbra, Portugal;
- ICNAS Pharma, University of Coimbra, 3000-548 Coimbra, Portugal
| | - Mariana Lapo Pais
- CIBIT/ICNAS, Institute for Nuclear Sciences Applied to Health, University of Coimbra, 3000-548 Coimbra, Portugal; (I.C.F.F.); (M.L.P.); (J.S.); (M.C.-B.)
| | - Fábio M. S. Rodrigues
- Coimbra Chemistry Centre, University of Coimbra, 3000-548 Coimbra, Portugal; (F.M.S.R.); (M.M.P.)
| | - José Sereno
- CIBIT/ICNAS, Institute for Nuclear Sciences Applied to Health, University of Coimbra, 3000-548 Coimbra, Portugal; (I.C.F.F.); (M.L.P.); (J.S.); (M.C.-B.)
- ICNAS Pharma, University of Coimbra, 3000-548 Coimbra, Portugal
| | - Miguel Castelo-Branco
- CIBIT/ICNAS, Institute for Nuclear Sciences Applied to Health, University of Coimbra, 3000-548 Coimbra, Portugal; (I.C.F.F.); (M.L.P.); (J.S.); (M.C.-B.)
- ICNAS Pharma, University of Coimbra, 3000-548 Coimbra, Portugal
- Faculty of Medicine, University of Coimbra, 3000-548 Coimbra, Portugal
| | - Cláudia Cavadas
- Faculty of Pharmacy, University of Coimbra, 3000-548 Coimbra, Portugal;
- CNC—Center for Neuroscience and Cell Biology, University of Coimbra, 3004-504 Coimbra, Portugal
- CIBB—Centre for Innovative Biomedicine and Biotechnology, University of Coimbra, 3004-531 Coimbra, Portugal
| | - Mariette M. Pereira
- Coimbra Chemistry Centre, University of Coimbra, 3000-548 Coimbra, Portugal; (F.M.S.R.); (M.M.P.)
| | - Antero J. Abrunhosa
- CIBIT/ICNAS, Institute for Nuclear Sciences Applied to Health, University of Coimbra, 3000-548 Coimbra, Portugal; (I.C.F.F.); (M.L.P.); (J.S.); (M.C.-B.)
- ICNAS Pharma, University of Coimbra, 3000-548 Coimbra, Portugal
| |
Collapse
|
2
|
Laferriere-Holloway TS, Rios A, Lu Y, Okoro CC, van Dam RM. A rapid and systematic approach for the optimization of radio thin-layer chromatography resolution. J Chromatogr A 2023; 1687:463656. [PMID: 36463649 PMCID: PMC9894532 DOI: 10.1016/j.chroma.2022.463656] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 11/16/2022] [Accepted: 11/17/2022] [Indexed: 11/23/2022]
Abstract
Radiopharmaceutical analysis is limited by conventional methods. Radio-HPLC may be inaccurate for some compounds (e.g., 18F-radiopharmaceuticals) due to radionuclide sequester. Radio-TLC is simpler, faster, and detects all species but has limited resolution. Imaging-based readout of TLC plates (e.g., using Cerenkov luminescence imaging) can improve readout resolution, but the underlying chromatographic separation efficiency may be insufficient to resolve chemically similar species such as product and precursor-derived impurities. This study applies a systematic mobile phase optimization method, PRISMA, to improve radio-TLC resolution. The PRISMA method optimizes the mobile phase by selecting the correct solvent, optimizing solvent polarity, and optimizing composition. Without prior knowledge of impurities and by simply observing the separation resolution between a radiopharmaceutical and its nearest radioactive or non-radioactive impurities (observed via UV imaging) for different mobile phases, the PRISMA method enabled the development of high-resolution separation conditions for a wide range of 18F-radiopharmaceuticals ( [18F]PBR-06, [18F]FEPPA, [18F]Fallypride, [18F]FPEB, and [18F]FDOPA). Each optimization required a single batch of crude radiopharmaceutical and a few hours. Interestingly, the optimized TLC method provided greater accuracy (compared to other published TLC methods) in determining the product abundance of one radiopharmaceutical studied in more depth ( [18F]Fallypride) and was capable of resolving a comparable number of species as isocratic radio-HPLC. We used the PRISMA-optimized mobile phase for [18F]FPEB in combination with multi-lane radio-TLC techniques to evaluate reaction performance during high-throughput synthesis optimization of [18F]FPEB. The PRISMA methodology, in combination with high-resolution radio-TLC readout, enables a rapid and systematic approach to achieving high-resolution and accurate analysis of radiopharmaceuticals without the need for radio-HPLC.
Collapse
Affiliation(s)
- Travis S Laferriere-Holloway
- Department of Molecular & Medical Pharmacology, David Geffen School of Medicine, University of California Los Angeles (UCLA), Los Angeles, CA, USA; Crump Institute for Molecular Imaging, UCLA, Los Angeles, CA, USA.
| | - Alejandra Rios
- Physics and Biology in Medicine Interdepartmental Graduate Program, UCLA, Los Angeles, CA, USA; Crump Institute for Molecular Imaging, UCLA, Los Angeles, CA, USA
| | - Yingqing Lu
- Physics and Biology in Medicine Interdepartmental Graduate Program, UCLA, Los Angeles, CA, USA; Crump Institute for Molecular Imaging, UCLA, Los Angeles, CA, USA
| | - Chelsea C Okoro
- Institute for Society and Genetics, UCLA, Los Angeles, CA, USA; Crump Institute for Molecular Imaging, UCLA, Los Angeles, CA, USA
| | - R Michael van Dam
- Department of Molecular & Medical Pharmacology, David Geffen School of Medicine, University of California Los Angeles (UCLA), Los Angeles, CA, USA; Physics and Biology in Medicine Interdepartmental Graduate Program, UCLA, Los Angeles, CA, USA; Crump Institute for Molecular Imaging, UCLA, Los Angeles, CA, USA.
| |
Collapse
|
3
|
Microliter-scale reaction arrays for economical high-throughput experimentation in radiochemistry. Sci Rep 2022; 12:10263. [PMID: 35715457 PMCID: PMC9205965 DOI: 10.1038/s41598-022-14022-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Accepted: 05/31/2022] [Indexed: 01/14/2023] Open
Abstract
The increasing number of positron-emission tomography (PET) tracers being developed to aid drug development and create new diagnostics has led to an increased need for radiosynthesis development and optimization. Current radiosynthesis instruments are designed to produce large-scale clinical batches and are often limited to performing a single synthesis before they must be decontaminated by waiting for radionuclide decay, followed by thorough cleaning or disposal of synthesizer components. Though with some radiosynthesizers it is possible to perform a few sequential radiosyntheses in a day, none allow for parallel radiosyntheses. Throughput of one or a few experiments per day is not well suited for rapid optimization experiments. To combat these limitations, we leverage the advantages of droplet-radiochemistry to create a new platform for high-throughput experimentation in radiochemistry. This system contains an array of 4 heaters, each used to heat a set of 16 reactions on a small chip, enabling 64 parallel reactions for the rapid optimization of conditions in any stage of a multi-step radiosynthesis process. As examples, we study the syntheses of several 18F-labeled radiopharmaceuticals ([18F]Flumazenil, [18F]PBR06, [18F]Fallypride, and [18F]FEPPA), performing > 800 experiments to explore the influence of parameters including base type, base amount, precursor amount, solvent, reaction temperature, and reaction time. The experiments were carried out within only 15 experiment days, and the small volume (~ 10 μL compared to the ~ 1 mL scale of conventional instruments) consumed ~ 100 × less precursor per datapoint. This new method paves the way for more comprehensive optimization studies in radiochemistry and substantially shortening PET tracer development timelines.
Collapse
|
4
|
Frank C, Winter G, Rensei F, Samper V, Brooks AF, Hockley BG, Henderson BD, Rensch C, Scott PJH. Development and implementation of ISAR, a new synthesis platform for radiopharmaceutical production. EJNMMI Radiopharm Chem 2019; 4:24. [PMID: 31659546 PMCID: PMC6751239 DOI: 10.1186/s41181-019-0077-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Accepted: 08/30/2019] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND PET radiopharmaceutical development and the implementation of a production method on a synthesis module is a complex and time-intensive task since new synthesis methods must be adapted to the confines of the synthesis platform in use. Commonly utilized single fluid bus architectures put multiple constraints on synthesis planning and execution, while conventional microfluidic solutions are limited by compatibility at the macro-to-micro interface. In this work we introduce the ISAR synthesis platform and custom-tailored fluid paths leveraging up to 70 individually addressable valves on a chip-based consumable. The ISAR synthesis platform replaces traditional stopcock valve manifolds with a fluidic chip that integrates all fluid paths (tubing) and valves into one consumable and enables channel routing without the single fluid bus constraint. ISAR can scale between the macro- (10 mL), meso- (0.5 mL) and micro- (≤0.05 mL) domain seamlessly, addressing the macro-to-micro interface challenge and enabling custom tailored fluid circuits for a given application. In this paper we demonstrate proof-of-concept by validating a single chip design to address the challenge of synthesizing multiple batches of [13N]NH3 for clinical use throughout the workday. RESULTS ISAR was installed at an academic PET Center and used to manufacture [13N]NH3 in > 96% radiochemical yield. Up to 9 batches were manufactured with a single consumable chip having parallel paths without the need to open the hot-cell. Quality control testing confirmed the ISAR-based [13N]NH3 met existing clinical release specifications, and utility was demonstrated by imaging a rodent with [13N]NH3 produced on ISAR. CONCLUSIONS ISAR represents a new paradigm in radiopharmaceutical production. Through a new system architecture, ISAR integrates the principles of microfluidics with the standard volumes and consumables established in PET Centers all over the world. Proof-of-concept has been demonstrated through validation of a chip design for the synthesis of [13N]NH3 suitable for clinical use.
Collapse
Affiliation(s)
| | - Georg Winter
- GE Healthcare, Oskar-Schlemmer-Str. 11, 80807 Munich, Germany
| | | | | | - Allen F. Brooks
- Department of Radiology, University of Michigan, 2276 Medical Science Bldg I, SPC 5610, Ann Arbor, MI 48109 USA
| | - Brian G. Hockley
- Department of Radiology, University of Michigan, 2276 Medical Science Bldg I, SPC 5610, Ann Arbor, MI 48109 USA
| | - Bradford D. Henderson
- Department of Radiology, University of Michigan, 2276 Medical Science Bldg I, SPC 5610, Ann Arbor, MI 48109 USA
| | | | - Peter J. H. Scott
- Department of Radiology, University of Michigan, 2276 Medical Science Bldg I, SPC 5610, Ann Arbor, MI 48109 USA
| |
Collapse
|
5
|
Speed matters to raise molar radioactivity: Fast HPLC shortens the quality control of C-11 PET-tracers. Nucl Med Biol 2017; 57:28-33. [PMID: 29227813 DOI: 10.1016/j.nucmedbio.2017.11.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2017] [Revised: 09/25/2017] [Accepted: 11/15/2017] [Indexed: 11/23/2022]
Abstract
INTRODUCTION The decision whether an in-house produced short-lived radiopharmaceutical can be applied in-vivo is based on (1) the fulfilment of all quality criteria; (2) the availability of enough radioactivity for subsequent imaging; and (3) a molar activity (MA) above the set limits to guarantee safe administration without competing occupancy of the non-radioactive compound; and (4) an activity concentration, which is high enough for the application in certain preclinical studies. Hence, time reduction can be of major importance to increase final product yields, MA and activity concentrations. Usually, optimization in this respect only focuses on the radiotracer preparation steps but especially quality control (QC) is rarely even mentioned. Therefore, aim of this work is the establishment of optimized conditions for chromatographic analysis using HPLC within the QC to enable a significant time reduction, which then directly leads to an increase in available amount of radioactive product as well as MA at the time of application. METHODS An optimized set-up using ultra-performance liquid chromatography ((U)HPLC) was established and tested on 7 carbon-11 labelled radiotracers used within patient routine or clinical trials. RESULTS A drastic time reduction was achieved for all tracers. The optimized protocol lead to a gain of 5-7min (70-86% compared to the original set-up). CONCLUSIONS An accelerated (U)HPLC method for radiotracers labelled with short-lived radionuclides was successfully established and conditions were optimized for 7 clinically used radiotracers. The significant gain in QC time leads to a drastic increase in available radioactivity and specific activity at the time of tracer administration.
Collapse
|
6
|
Spies M, James GM, Berroterán-Infante N, Ibeschitz H, Kranz GS, Unterholzner J, Godbersen M, Gryglewski G, Hienert M, Jungwirth J, Pichler V, Reiter B, Silberbauer L, Winkler D, Mitterhauser M, Stimpfl T, Hacker M, Kasper S, Lanzenberger R. Assessment of Ketamine Binding of the Serotonin Transporter in Humans with Positron Emission Tomography. Int J Neuropsychopharmacol 2017; 21:145-153. [PMID: 29045739 PMCID: PMC5793827 DOI: 10.1093/ijnp/pyx085] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Accepted: 10/15/2017] [Indexed: 01/25/2023] Open
Abstract
BACKGROUND Comprehensive description of ketamine's molecular binding profile becomes increasingly pressing as use in real-life patient cohorts widens. Animal studies attribute a significant role in the substance's antidepressant effects to the serotonergic system. The serotonin transporter is a highly relevant target in this context, because it is central to depressive pathophysiology and treatment. This is, to our knowledge, the first study investigating ketamine's serotonin transporter binding in vivo in humans. METHODS Twelve healthy subjects were assessed twice using [11C]DASB positron emission tomography. A total of 0.50 mg/kg bodyweight ketamine was administered once i.v. prior to the second positron emission tomography scan. Ketamine plasma levels were determined during positron emission tomography. Serotonin transporter nondisplaceable binding potential was computed using a reference region model, and occupancy was calculated for 4 serotonin transporter-rich regions (caudate, putamen, thalamus, midbrain) and a whole-brain region of interest. RESULTS After administration of the routine antidepressant dose, ketamine showed <10% occupancy of the serotonin transporter, which is within the test-retest variability of [11C]DASB. A positive correlation between ketamine plasma levels and occupancy was shown. CONCLUSIONS Measurable occupancy of the serotonin transporter was not detectable after administration of an antidepressant dose of ketamine. This might suggest that ketamine binding of the serotonin transporter is unlikely to be a primary antidepressant mechanism at routine antidepressant doses, as substances that facilitate antidepressant effects via serotonin transporter binding (e.g., selective serotonin reuptake inhibitors) show 70% to 80% occupancy. Administration of high-dose ketamine is widening. Based on the positive relationship we find between ketamine plasma levels and occupancy, there is a need for investigation of ketamine's serotonin transporter binding at higher doses.
Collapse
Affiliation(s)
- Marie Spies
- Department of Psychiatry and Psychotherapy, Vienna, Austria
| | | | - Neydher Berroterán-Infante
- Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Vienna, Austria
| | - Harald Ibeschitz
- Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Vienna, Austria
| | - Georg S Kranz
- Department of Psychiatry and Psychotherapy, Vienna, Austria
| | | | | | | | - Marius Hienert
- Department of Psychiatry and Psychotherapy, Vienna, Austria
| | | | - Verena Pichler
- Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Vienna, Austria
| | | | | | | | - Markus Mitterhauser
- Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Vienna, Austria,Medical University of Vienna, Vienna, Austria,Ludwig Boltzmann Institute for Applied Diagnostics, Vienna, Austria
| | | | - Marcus Hacker
- Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Vienna, Austria
| | | | - Rupert Lanzenberger
- Department of Psychiatry and Psychotherapy, Vienna, Austria,Correspondence: Rupert Lanzenberger, MD, PD, Department of Psychiatry and Psychotherapy, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Wien ()
| |
Collapse
|
7
|
Rensch C, Lindner S, Salvamoser R, Leidner S, Böld C, Samper V, Taylor D, Baller M, Riese S, Bartenstein P, Wängler C, Wängler B. A solvent resistant lab-on-chip platform for radiochemistry applications. LAB ON A CHIP 2014; 14:2556-2564. [PMID: 24879121 DOI: 10.1039/c4lc00076e] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The application of microfluidics to the synthesis of Positron Emission Tomography (PET) tracers has been explored for more than a decade. Microfluidic benefits such as superior temperature control have been successfully applied to PET tracer synthesis. However, the design of a compact microfluidic platform capable of executing a complete PET tracer synthesis workflow while maintaining prospects for commercialization remains a significant challenge. This study uses an integral system design approach to tackle commercialization challenges such as the material to process compatibility with a path towards cost effective lab-on-chip mass manufacturing from the start. It integrates all functional elements required for a simple PET tracer synthesis into one compact radiochemistry platform. For the lab-on-chip this includes the integration of on-chip valves, on-chip solid phase extraction (SPE), on-chip reactors and a reversible fluid interface while maintaining compatibility with all process chemicals, temperatures and chip mass manufacturing techniques. For the radiochemistry device it includes an automated chip-machine interface enabling one-move connection of all valve actuators and fluid connectors. A vial-based reagent supply as well as methods to transfer reagents efficiently from the vials to the chip has been integrated. After validation of all those functional elements, the microfluidic platform was exemplarily employed for the automated synthesis of a Gastrin-releasing peptide receptor (GRP-R) binding the PEGylated Bombesin BN(7-14)-derivative ([(18)F]PESIN) based PET tracer.
Collapse
Affiliation(s)
- Christian Rensch
- GE Global Research, Freisinger Landstrasse 50, 85748 Garching bei Munich, Germany.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Pascali G, Watts P, Salvadori PA. Microfluidics in radiopharmaceutical chemistry. Nucl Med Biol 2013; 40:776-87. [DOI: 10.1016/j.nucmedbio.2013.04.004] [Citation(s) in RCA: 74] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2013] [Revised: 03/20/2013] [Accepted: 04/03/2013] [Indexed: 11/28/2022]
|
9
|
Rensch C, Jackson A, Lindner S, Salvamoser R, Samper V, Riese S, Bartenstein P, Wängler C, Wängler B. Microfluidics: a groundbreaking technology for PET tracer production? Molecules 2013; 18:7930-56. [PMID: 23884128 PMCID: PMC6270045 DOI: 10.3390/molecules18077930] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2013] [Revised: 06/21/2013] [Accepted: 07/03/2013] [Indexed: 11/16/2022] Open
Abstract
Application of microfluidics to Positron Emission Tomography (PET) tracer synthesis has attracted increasing interest within the last decade. The technical advantages of microfluidics, in particular the high surface to volume ratio and resulting fast thermal heating and cooling rates of reagents can lead to reduced reaction times, increased synthesis yields and reduced by-products. In addition automated reaction optimization, reduced consumption of expensive reagents and a path towards a reduced system footprint have been successfully demonstrated. The processing of radioactivity levels required for routine production, use of microfluidic-produced PET tracer doses in preclinical and clinical imaging as well as feasibility studies on autoradiolytic decomposition have all given promising results. However, the number of microfluidic synthesizers utilized for commercial routine production of PET tracers is very limited. This study reviews the state of the art in microfluidic PET tracer synthesis, highlighting critical design aspects, strengths, weaknesses and presenting several characteristics of the diverse PET market space which are thought to have a significant impact on research, development and engineering of microfluidic devices in this field. Furthermore, the topics of batch- and single-dose production, cyclotron to quality control integration as well as centralized versus de-centralized market distribution models are addressed.
Collapse
Affiliation(s)
- Christian Rensch
- GE Global Research, Freisinger Landstrasse 50, Garching bei Munich 85748, Germany; E-Mails: (R.S.); (V.S.)
| | - Alexander Jackson
- GE Healthcare, Life Sciences, The Grove Centre, White Lion Rd., Amersham HP7 9LL, UK; E-Mails: (A.J.); (S.R.)
| | - Simon Lindner
- University Hospital Munich, Department of Nuclear Medicine, Ludwig Maximilians-University, Munich 81377, Germany; E-Mails: (S.L.); (P.B.); (C.W.)
| | - Ruben Salvamoser
- GE Global Research, Freisinger Landstrasse 50, Garching bei Munich 85748, Germany; E-Mails: (R.S.); (V.S.)
| | - Victor Samper
- GE Global Research, Freisinger Landstrasse 50, Garching bei Munich 85748, Germany; E-Mails: (R.S.); (V.S.)
| | - Stefan Riese
- GE Healthcare, Life Sciences, The Grove Centre, White Lion Rd., Amersham HP7 9LL, UK; E-Mails: (A.J.); (S.R.)
| | - Peter Bartenstein
- University Hospital Munich, Department of Nuclear Medicine, Ludwig Maximilians-University, Munich 81377, Germany; E-Mails: (S.L.); (P.B.); (C.W.)
| | - Carmen Wängler
- University Hospital Munich, Department of Nuclear Medicine, Ludwig Maximilians-University, Munich 81377, Germany; E-Mails: (S.L.); (P.B.); (C.W.)
- Biomedical Chemistry, Department of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim of Heidelberg University, Mannheim 68167, Germany
| | - Björn Wängler
- Molecular Imaging and Radiochemistry, Department of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim of Heidelberg University, Mannheim 68167, Germany
| |
Collapse
|
10
|
|