1
|
Zidouh I, Arectout A, Bellahsaouia M, Elaarabi D, Chamlal H, Maroufi B, Sadeq Y, Tazi M, Rodenas J, Boukhal H, Chakir E. Comparison of OSL and TL dosimetry systems against IEC and ICRP standards. Appl Radiat Isot 2023; 196:110732. [PMID: 36924534 DOI: 10.1016/j.apradiso.2023.110732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 02/13/2023] [Accepted: 02/15/2023] [Indexed: 03/17/2023]
Abstract
Personal and environmental radiation monitoring services are widely used through luminescent techniques. In this paper, we practiced performance testing on thermoluminescent and optically stimulated luminescent dosimeters by assessing their homogeneity, linearity, energy, and angular dependence tests. The IEC and ICRP requirements were used to compare the performance response of dosimeters. Based on the experimental results, we realized that both detectors comply with the international criteria. The homogeneity percentage was 8.9% and 13.7% for TL and OSL detectors, respectively. The percentage deviation of the linearity test does not exceed 10% for both dosimeters except for the TL dosimeters at low irradiation dose. For the angular dependence, deviations were less than 2% for TLDs and 5% for OSLDs. These detectors display mean values of the relative energy response of -15.29% and -6.51% for OSL and TL detectors. Generally, TL materials manifested low sensitivity to radiation dose levels. On the other hand, the OSLDs demonstrated a more pronounced under-response to energy beam qualities than TLDs. Regarding COV tests, TL and OSL dosimeters have passed the c2 test.
Collapse
Affiliation(s)
- I Zidouh
- LPMS, Faculty of Sciences, University Ibn Tofail Kenitra, Morocco.
| | - A Arectout
- ERSN, Faculty of Sciences, Abdelmalek Essaadi University, Tetouan, Morocco
| | - M Bellahsaouia
- LPMS, Faculty of Sciences, University Ibn Tofail Kenitra, Morocco
| | - D Elaarabi
- LPMS, Faculty of Sciences, University Ibn Tofail Kenitra, Morocco
| | - H Chamlal
- Centre National de Radioprotection (CNRP), Salé, Morocco
| | - B Maroufi
- LPMS, Faculty of Sciences, University Ibn Tofail Kenitra, Morocco
| | - Y Sadeq
- Centre National de Radioprotection (CNRP), Salé, Morocco
| | - M Tazi
- Centre National de Radioprotection (CNRP), Salé, Morocco
| | - J Rodenas
- Instituto de Seguridad Industrial, Radiofísica y Medioambiental (ISIRYM), Universitat Politècnica de València, Valencia, Spain
| | - H Boukhal
- ERSN, Faculty of Sciences, Abdelmalek Essaadi University, Tetouan, Morocco
| | - E Chakir
- LPMS, Faculty of Sciences, University Ibn Tofail Kenitra, Morocco
| |
Collapse
|
2
|
Preliminary study on radioluminescence dose rate measurement of α-Al2O3:C coupled to SiPM. RADIAT MEAS 2022. [DOI: 10.1016/j.radmeas.2022.106851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|