Merfort R, Maffulli N, Hofmann UK, Hildebrand F, Simeone F, Eschweiler J, Migliorini F. Head, acetabular liner composition, and rate of revision and wear in total hip arthroplasty: a Bayesian network meta-analysis. Sci Rep 2023; 13:20327. [PMID: 37989863 PMCID: PMC10663607 DOI: 10.1038/s41598-023-47670-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 11/16/2023] [Indexed: 11/23/2023] Open
Abstract
Total hip arthroplasty (THA) is a common procedure for patients suffering from hip pain e.g. from osteoarthritis, osteonecrosis, or hip fractures. The satisfaction of patients undergoing THA is influenced by the choice of implant type and material, with one key factor being the selection of the appropriate material combination for the bearing surface. In this Bayesian network meta-analysis, we investigated the impact of material combinations for the bearing surface on the longevity of hip implants. The wear penetration rate per year and the total wear penetration in the liner resulting from different material combinations, as well as the survival rate at last follow-up, were examined. We analyzed a total of 663,038 THAs, with 55% of patients being women. Mean patient age was 59.0 ± 8.1 years and mean BMI 27.6 ± 2.6 kg/m2. The combination of an aluminium oxide (Al2O3) head and an Al2O3 liner demonstrated the lowest wear penetration at last follow-up and the lowest rate of wear penetration per year. Additionally, the combination of a crosslinked polyethylene (XLPE) liner and a zircon oxide (ZrO2) head demonstrated the lowest rate of revision at last follow-up. These findings underscore the importance of careful material selection for hip implant bearing surfaces to optimize their longevity and patient satisfaction after THA.
Collapse
Affiliation(s)
- Ricarda Merfort
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, 52074, Aachen, Germany
| | - Nicola Maffulli
- Department of Medicine and Psicology, University La Sapienza, Rome, Italy
- Faculty of Medicine, School of Pharmacy and Bioengineering, Keele University, Thornburrow Drive, Stoke-on-Trent, England, UK
- Centre for Sports and Exercise Medicine, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, Mile End Hospital, 275 Bancroft Road, London, E1 4DG, England, UK
| | - Ulf Krister Hofmann
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, 52074, Aachen, Germany
| | - Frank Hildebrand
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, 52074, Aachen, Germany
| | - Francesco Simeone
- Department of Orthopaedic and Trauma Surgery, Academic Hospital of Bolzano (SABES-ASDAA), Teaching Hospital of the Paracelsus Medical University, 39100, Bolzano, Italy
| | - Jörg Eschweiler
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, 52074, Aachen, Germany
| | - Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, 52074, Aachen, Germany.
- Department of Orthopaedic and Trauma Surgery, Academic Hospital of Bolzano (SABES-ASDAA), Teaching Hospital of the Paracelsus Medical University, 39100, Bolzano, Italy.
| |
Collapse
|
2
|
Migliorini F, Maffulli N, Pilone M, Bell A, Hildebrand F, Konrads C. Risk factors for liner wear and head migration in total hip arthroplasty: a systematic review. Sci Rep 2023; 13:15612. [PMID: 37730762 PMCID: PMC10511625 DOI: 10.1038/s41598-023-42809-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 09/14/2023] [Indexed: 09/22/2023] Open
Abstract
Total hip arthroplasty (THA) is a successful orthopaedic surgical procedure, and its longevity depends on bearing components and implant fixation. Optimizing polyethylene and ceramics has led to improved wear parameters and contributed to improved long-term outcomes. The present systematic review investigated whether time span from implantation, patient characteristics and performance status exert an influence on liner wear and head migration in THA. This study was conducted in conformity to the 2020 PRISMA guidelines. All the clinical investigations which reported quantitative data on the amount of liner wear and head migration in THA were considered. Only studies which reported quantitative data at least on one of the following patient characteristics were suitable: mean age, mean BMI (kg/m2), sex, side, time span between the index THA and the last follow-up (months) were eligible. A multiple linear model regression analysis was employed to verify the association between patient characteristics and the amount of liner wear and/or head migration. The Pearson Product-Moment Correlation Coefficient was used to assess the association between variables. Data from 12,629 patients were considered. The mean length of the follow-up was 90.5 ± 50.9 months. The mean age of patients at surgery was 58.4 ± 9.4 years, and the mean BMI was 27.2 ± 2.5 kg/m2. 57% (7199 of 12,629 patients) were women, and in 44% (5557 of 12,629 patients) THAs were performed on the left. The mean pre-operative Harris hip score was 46.5 ± 6.0 points. There was evidence of a moderate positive association between the amount of liner wear and the time elapsed between the index surgery to the follow-up (P = 0.02). There was evidence of a moderate positive association between the amount of head migration and the time elapsed between the index surgery to the follow-up (P = 0.01). No further statistically significant association was found. The time elapsed between the index surgery to the follow-up was the most important factor which influence the head migration and liner wear in THA. Patients' characteristics and preoperative physical activity did not influence the amount of head migration and liner wear.
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
- Department of Orthopaedic and Trauma Surgery, Academic Hospital of Bolzano, Teaching Hospital of Paracelsus Medical University (PMU), 39100, Bolzano, Italy.
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, Simmerath, Germany.
| | - Nicola Maffulli
- Department of Orthopaedic and Trauma Surgery, Hospital Sant'Andrea, University of Rome La Sapienza, Rome, Italy
- School of Pharmacy and Bioengineering, Keele University Faculty of Medicine, Stoke on Trent, ST4 7QB, England
- Queen Mary University of London, Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Mile End Hospital, London, E1 4DG, England
| | - Marco Pilone
- Residency Program in Orthopaedics and Traumatology, University of Milan, 20122, Milan, Italy
| | - Andreas Bell
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, Simmerath, Germany
| | - Frank Hildebrand
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Christian Konrads
- Department of Orthopaedics and Traumatology, Helios Hanseatic Hospital Stralsund, 18435, Stralsund, Germany
- Medical Faculty, University of Tübingen, 72076, Tübingen, Germany
| |
Collapse
|
3
|
Savin L, Pinteala T, Mihai DN, Mihailescu D, Miu SS, Sirbu MT, Veliceasa B, Popescu DC, Sirbu PD, Forna N. Updates on Biomaterials Used in Total Hip Arthroplasty (THA). Polymers (Basel) 2023; 15:3278. [PMID: 37571172 PMCID: PMC10422432 DOI: 10.3390/polym15153278] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 07/30/2023] [Accepted: 07/31/2023] [Indexed: 08/13/2023] Open
Abstract
One of the most popular and effective orthopedic surgical interventions for treating a variety of hip diseases is total hip arthroplasty. Despite being a radical procedure that involves replacing bone and cartilaginous surfaces with biomaterials, it produces excellent outcomes that significantly increase the patient's quality of life. Patient factors and surgical technique, as well as biomaterials, play a role in prosthetic survival, with aseptic loosening (one of the most common causes of total hip arthroplasty failure) being linked to the quality of biomaterials utilized. Over the years, various biomaterials have been developed to limit the amount of wear particles generated over time by friction between the prosthetic head (metal alloys or ceramic) and the insert fixed in the acetabular component (polyethylene or ceramic). An ideal biomaterial must be biocompatible, have a low coefficient of friction, be corrosion resistant, and have great mechanical power. Comprehensive knowledge regarding what causes hip arthroplasty failure, as well as improvements in biomaterial quality and surgical technique, will influence the survivability of the prosthetic implant. The purpose of this article was to assess the benefits and drawbacks of various biomaterial and friction couples used in total hip arthroplasties by reviewing the scientific literature published over the last 10 years.
Collapse
Affiliation(s)
- Liliana Savin
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| | - Tudor Pinteala
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| | - Dana Nicoleta Mihai
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
- Department of Protheses Technology, Faculty of Dental Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Dan Mihailescu
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| | - Smaranda Stefana Miu
- Department of Rehabilitation, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| | - Mihnea Theodor Sirbu
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
| | - Bogdan Veliceasa
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
| | - Dragos Cristian Popescu
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
| | - Paul Dan Sirbu
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| | - Norin Forna
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| |
Collapse
|
4
|
Zheng C, Xu J, Wu L, Wu Y, Liu Y, Shen B. Comparisons of Different Bearing Surfaces in Cementless Total Hip Arthroplasty: A Systematic Review and Bayesian Network Analysis. J Arthroplasty 2023; 38:600-609. [PMID: 36265721 DOI: 10.1016/j.arth.2022.10.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 10/06/2022] [Accepted: 10/11/2022] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND We aimed to make comparisons of different bearing surfaces in patients after cementless total hip arthroplasty. METHODS The network meta-analysis was guided by the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guideline. The primary outcomes were implant survival and Harris hip score (HHS). Secondary outcomes included linear wear rates and serum level of metal ions. Subgroup analyses were performed by: (1) classifying head sizes as small and large; (2) femoral heads as ceramic and metal; and (3) liners as metal, ceramic, polyethylene, highly cross-linked polyethylene (HXP), or vitamin E-infused highly cross-linked polyethylene (HXPE). A total of 64 eligible RCTs with different bearings were assessed. Overall inconsistency and heterogeneity were acceptable. RESULTS In the 10 years follow-up, metal-on-polythene and ceramic-on-polythene bearings with small heads showed higher risk for revisions compared with metal-on-HXP and ceramic-on-HXP bearings with small heads. Similarly, only metal or ceramic-on-polythene bearings with small heads showed inferiority in HHS compared with other bearings. Conventional polyethylene liners showed higher linear wear rates compared with HXP, HXPE, and ceramic liners at 5 and 10 years after surgery, while metal-on-metal and ceramic-on-metal bearings showed higher serum level of cobalt and chromium. CONCLUSION Bearings containing HXP, HXPE, and ceramic liners showed comparable survivorship and hip function at follow-up of 5 and 10 years. Hard-on-hard bearings containing metal had higher serum level of metal ions than others. Bearings containing conventional polyethylene had worse performance in terms of implant survival, hip function, and wear rates. LEVEL OF EVIDENCE Level I.
Collapse
Affiliation(s)
- Che Zheng
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Jiawen Xu
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Liming Wu
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Yuangang Wu
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Yuan Liu
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| | - Bin Shen
- Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China
| |
Collapse
|
5
|
Mertz KC, Yang J, Chung BC, Chen X, Mayfield CK, Heckmann ND. Ceramic Femoral Heads Exhibit Lower Wear Rates Compared to Cobalt Chrome: A Meta-Analysis. J Arthroplasty 2023; 38:397-405. [PMID: 36108994 DOI: 10.1016/j.arth.2022.09.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 09/06/2022] [Accepted: 09/06/2022] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Wear between the femoral head and acetabular liners continues to limit the longevity of total hip arthroplasty implants despite advances in implant materials. The purpose of this meta-analysis was to compare linear wear rates of cobalt-chromium (CoCr) and fourth-generation ceramic femoral heads on highly cross-linked polyethylene (XLPE) liners. METHODS A systematic review following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was conducted to identify all studies between 2003 and 2020 that examined in vivo wear rates of either fourth-generation ceramics or CoCr femoral heads on XLPE liners. Studies were analyzed in a weighted means analysis of wear rates and a random effects meta-analysis. RESULTS A total of 36 studies met inclusion criteria (1,657 CoCr and 659 ceramic patients). The pooled, weighted mean wear rate was 0.063 mm/year (standard deviation [SD]: 0.061, confidence interval [CI]: 0.049-0.077) for CoCr and 0.047 mm/year (SD: 0.057, CI: 0.033-0.062; P < .01) for ceramic (P < .01). A meta-analysis of 4 studies directly comparing ceramic and CoCr found that CoCr heads demonstrated 0.029 mm/year more wear than ceramic heads (95% CI: 0.026-0.059, P = .306). Mean wear for 32-mm heads was significantly higher for ceramic (P < .01), while mean wear for 36-mm heads was significantly higher for CoCr (P < .01). CONCLUSION Fourth-generation ceramic femoral heads were found to have significantly lower wear rates than CoCr heads. Unlike previous studies, this meta-analysis included only in vivo studies and those with the same generation of highly XLPE liners.
Collapse
Affiliation(s)
- Kevin C Mertz
- Keck School of Medicine of the University of Southern California, Los Angeles, California
| | - JaeWon Yang
- University of Washington Medical Center, Seattle, Washington
| | - Brian C Chung
- Keck School of Medicine of the University of Southern California, Los Angeles, California
| | | | - Cory K Mayfield
- Keck School of Medicine of the University of Southern California, Los Angeles, California
| | - Nathanael D Heckmann
- Keck School of Medicine of the University of Southern California, Los Angeles, California
| |
Collapse
|
6
|
Spir IAZ, Anzai A, Utino A, Katayama H, Tosello G, Nery MM, Anhesini M, Tiezzi OS, Otani P, Bernardo WM. Comparison between ceramic-on-polyethylene versus metal-on-polyethylene prostheses in Total Hip Arthroplasties: a systematic review and meta-analysis. Rev Assoc Med Bras (1992) 2022; 68:1611-1618. [PMID: 36477100 PMCID: PMC9779979 DOI: 10.1590/1806-9282.022d6812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 11/09/2022] [Indexed: 12/12/2022] Open
Abstract
The Guidelines Project, an initiative of the Brazilian Medical Association, aims to combine information from the medical field to standardize how to conduct, and to assist in the reasoning and decision-making of doctors. The information provided by this project must be critically evaluated by the physician responsible for the conduct that will be adopted, depending on the conditions and the clinical condition of each patient.
Collapse
Affiliation(s)
| | - Adriano Anzai
- Unimed, Evidence-Based Medicine Center – Presidente Prudente (SP), Brazil
| | - Armelim Utino
- Unimed, Evidence-Based Medicine Center – Presidente Prudente (SP), Brazil
| | - Haroldo Katayama
- Unimed, Evidence-Based Medicine Center – Presidente Prudente (SP), Brazil
| | - Giuliano Tosello
- Unimed, Evidence-Based Medicine Center – Presidente Prudente (SP), Brazil
| | - Mary Martins Nery
- Unimed, Evidence-Based Medicine Center – Presidente Prudente (SP), Brazil
| | - Mauricio Anhesini
- Unimed, Evidence-Based Medicine Center – Presidente Prudente (SP), Brazil
| | | | - Pericles Otani
- Unimed, Evidence-Based Medicine Center – Presidente Prudente (SP), Brazil
| | - Wanderley Marques Bernardo
- Federação das Unimeds do Estado de São Paulo, Federal Council of Medicine – São Paulo (SP), Brazil.,Corresponding author:
| |
Collapse
|
7
|
Characterization of In Vivo Damage on Retrieved Total Shoulder Glenoid Liners. LUBRICANTS 2022. [DOI: 10.3390/lubricants10080166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
An attempt was made to retrieve glenoid liners from revision surgery to undertake a retrospective study to measure the resulting in vivo damage. Since the glenoid liners are circumferential, the curvature changes at every point in the component, an “assisting arm” was designed to hold the liner firmly, thus allowing accurate microscopic measurements. We characterized the damage in terms of pitting, embedded debris, complete fracture, abrasion, deformation, delamination, burnishing, grooving, and scratching that took place mutually exclusively. This study of 26 liners showed embedded debris was the most underrated damage mode found on the liners, followed by pitting and abrasion, representing 65.2% and 52.2% of the liners, respectively. The prevalence of pitting in over half the samples examined is indicative of free-radical oxidation, resulting in a decrease in physical strength from morphological changes in the microstructure. These may initiate from different pathways, however, they may interact with other processes in which other damage initiates and grows, resulting in higher damage causing premature failure due to wear. A probabilistic approach was developed to generate survival time for these liners and may provide a statistical removal time of the glenoid liners in the future.
Collapse
|
8
|
Naito Y, Hasegawa M, Tone S, Wakabayashi H, Sudo A. Thirteen-year results of cementless total hip arthroplasty with zirconia heads on highly cross-linked polyethylene. Mod Rheumatol 2020; 31:1045-1049. [PMID: 33153348 DOI: 10.1080/14397595.2020.1847753] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVES Zirconia ceramic was introduced for femoral heads because of its mechanical strength and fracture toughness. Highly cross-linked polyethylene has been shown to achieve wear reduction compared to conventional polyethylene. The purpose of this study was to investigate the long-term results of cementless total hip arthroplasty with zirconia femoral heads on highly cross-linked polyethylene. METHODS Radiographic measurements of two-dimensional femoral head penetration into the polyethylene were performed with a computerized method (PolyWare) in 93 hips at a mean follow-up of 13 years. The steady-state wear rates were measured based on the radiographs from the first year after surgery to the final follow-up. RESULTS The mean Merle d'Aubigné and Postel score had improved significantly from 10.9 points preoperatively to 15.3 postoperatively (p < 0.001). Osteolysis was not found around the implant, and no zirconia heads had fractures. The total head penetration rate was 0.04 mm/year, and the steady-state wear rate was 0.02 mm/year. Kaplan-Meier survivorship with the endpoint of revision was 97% (95% confidence interval [CI], 92% to 99%) at 10 years. CONCLUSION Zirconia on highly cross-linked polyethylene demonstrated extremely low wear properties at long-term follow-up.
Collapse
Affiliation(s)
- Yohei Naito
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Mie, Japan
| | - Masahiro Hasegawa
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Mie, Japan
| | - Shine Tone
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Mie, Japan
| | - Hiroki Wakabayashi
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Mie, Japan
| | - Akihiro Sudo
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Mie, Japan
| |
Collapse
|
9
|
Laende EK, Richardson CG, Dunbar MJ. Migration and Wear of a Dual Mobility Acetabular Construct at 3 Years Measured by Radiostereometric Analysis. J Arthroplasty 2020; 35:1109-1116. [PMID: 31866254 DOI: 10.1016/j.arth.2019.11.010] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 10/27/2019] [Accepted: 11/07/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The anatomic dual mobility (ADM) acetabular component was introduced because of previously described low dislocation rates for this type of construct. The shape of the anatomic cup and the motion of polyethylene liner may have implications for acetabular cup fixation and polyethylene liner wear; therefore, the purpose of this study was to assess the migration patterns and wear rates of the ADM component using radiostereometric analysis. METHODS Uncemented ADM acetabular components were implanted in 27 patients. Radiostereometric analysis exams were taken at 6 follow-up visits over 3 years. Proximal translation and sagittal rotation of the cup and polyethylene total wear and wear rates were calculated. Oxford 12 Hip scores and satisfaction were recorded. RESULTS Mean proximal translation was below the 0.2 mm threshold at 2 years associated with acceptable long-term survivorship (0.16 mm [standard deviation {SD} 0.31] at 3 years). Mean sagittal rotation was 0.29 degrees (SD 1.03) and was greater in female subjects (P < .001). Following bedding-in, the annual wear rate was 0.02 mm/y, below the 0.1 mm/y threshold. There was no association between cup migration and polyethylene wear. Patient satisfaction at 3 years was 96%. Mean Oxford 12 Hip scores improved from 21 (SD 7) preoperatively to 43 (SD 7) 3 years postoperatively. CONCLUSIONS The ADM cup demonstrated stable migration at 3 years indicating low risk for aseptic loosening. Bedding-in in the first year was followed by low annual wear rates. These finding suggest no increased risk of the dual mobility and anatomic design on fixation or wear.
Collapse
Affiliation(s)
- Elise K Laende
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada; School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - C Glen Richardson
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | - Michael J Dunbar
- Division of Orthopaedics, Department of Surgery, Dalhousie University and QEII Health Sciences Centre, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada; School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| |
Collapse
|
10
|
Mei XY, Gong YJ, Safir O, Gross A, Kuzyk P. Long-term outcomes of total hip arthroplasty in patients younger than 55 years: a systematic review of the contemporary literature. Can J Surg 2020; 62:249-258. [PMID: 31348632 DOI: 10.1503/cjs.013118] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Background Total hip arthroplasty (THA) is increasingly performed in younger patients despite the lack of comprehensive assessment of long-term outcomes. We systematically reviewed the contemporary literature to assess the 1) indications, 2) implant selection and long-term survivorship, 3) complication and reoperation rates and 4) radiographic and functional outcomes of primary THA in patients younger than 55 years. Methods We searched the Embase and MEDLINE databases for English-language articles published between 2000 and 2018 that reported outcomes of primary THA in patients younger than 55 years with a minimum follow-up duration of 10 years. Results Thirty-two studies reporting on 3219 THA procedures performed in 2434 patients met our inclusion criteria. The most common preoperative diagnoses were avascular necrosis (1044 [32.4%]), osteoarthritis (870 [27.0%]) and developmental dysplasia of the hip (627 [19.5%]). Modular implants (3001 [93.2%]), cementless fixation (2214 [68.8%]) and metal-on-polyethylene bearings (1792 [55.7%]) were frequently used. The mean 5- and 10-year survival rates were 98.7% and 94.6%, respectively. Data on survival beyond 10 years were heterogeneous, with values of 27%–99.5% at 10–14 years, 59%–84% at 15–19 years, 70%–77% at 20–24 years and 60% at 25–30 years. Rates of dislocation, deep infection and reoperation for any reason were 2.4%, 1.2% and 16.3%, respectively. The mean Harris Hip Score improved from 43.6/100 to 91.0/100. Conclusion Total hip arthroplasty in patients younger than 55 years provides reliable outcomes at up to 10 years. Future studies should evaluate the outcomes of THA in this population at 15–20 years’ follow-up.
Collapse
Affiliation(s)
- Xin Yu Mei
- From the Department of Orthopaedic Surgery, Mount Sinai Hospital, Toronto, Ont. (Mei, Safir, Gross, Kuzyk); and the Department of Family Medicine, Queen’s University, Kingston, Ont. (Gong)
| | - Ying Jia Gong
- From the Department of Orthopaedic Surgery, Mount Sinai Hospital, Toronto, Ont. (Mei, Safir, Gross, Kuzyk); and the Department of Family Medicine, Queen’s University, Kingston, Ont. (Gong)
| | - Oleg Safir
- From the Department of Orthopaedic Surgery, Mount Sinai Hospital, Toronto, Ont. (Mei, Safir, Gross, Kuzyk); and the Department of Family Medicine, Queen’s University, Kingston, Ont. (Gong)
| | - Allan Gross
- From the Department of Orthopaedic Surgery, Mount Sinai Hospital, Toronto, Ont. (Mei, Safir, Gross, Kuzyk); and the Department of Family Medicine, Queen’s University, Kingston, Ont. (Gong)
| | - Paul Kuzyk
- From the Department of Orthopaedic Surgery, Mount Sinai Hospital, Toronto, Ont. (Mei, Safir, Gross, Kuzyk); and the Department of Family Medicine, Queen’s University, Kingston, Ont. (Gong)
| |
Collapse
|
11
|
Suraci A, Louati H, Culliton KN, Beaulé PE. Comparing In Vivo Performance of Two Highly Cross-Linked Polyethylene Thermal Treatments: Remelting vs Annealing in Acetabular Liners. J Arthroplasty 2019; 34:1509-1513. [PMID: 30956047 DOI: 10.1016/j.arth.2019.03.025] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2018] [Revised: 02/13/2019] [Accepted: 03/07/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The introduction of highly cross-linked polyethylene (HXLPE) acetabular liners has greatly improved the wear performance of metal-on-PE bearing surfaces used in total hip arthroplasty. Changing the sterilization environment and adding thermal treatments, such as remelting or annealing, were introduced to limit on-shelf and in vivo oxidation of cross-linked liners. This study compares the wear properties of the remelted A-CLASS (MicroPort) HXLPE liner to a sequentially annealed HXLPE. METHODS This retrospective study assessed linear and volumetric wear rates using Martell Hip Analysis Suite, and clinical performance through incidences of revision surgeries. A total of 80 remelted and 53 annealed liners were included in the wear analysis. All hips were reviewed for revisions. RESULTS There were no significant differences in steady-state linear or volumetric wear rates for remelted and annealed liners, 0.01 (-0.07 to 0.14) vs -0.01 (-0.11 to 0.1) mm/y (P = .28) and -1.03 (-30.99 to 45.43) vs -1.31 (-32.23 to 23.70) mm3/y (P = .30), respectively. Both cohorts were below the 0.1 mm/y linear wear threshold. The wear rates for patients with femoral head sizes ≥36 mm were not significantly different than those with 32 and 28 mm femoral head sizes (P = .60). Similarly, wear rates for patients with an excessively vertical acetabular component (>50°) were not significantly different than those with standard acetabular component orientations (P = .97). No hips were revised due to liner-related complications. CONCLUSION The wear rates of the A-CLASS remelted HXLPE acetabular liner wear rates were comparable to those of a sequentially annealed HXLPE. Further long-term studies are required to ensure acceptable resistance to fatigue and in vivo oxidation.
Collapse
Affiliation(s)
- Alison Suraci
- Division of Orthopaedic Surgery, The Ottawa Hospital, General Campus, Ottawa, Ontario, Canada
| | - Hakim Louati
- Orthopaedic Biomechanics Laboratory, Division of Orthopaedic Surgery, The Ottawa Hospital Research Institute, Civic Campus, Ottawa, Ontario, Canada
| | - Kathryn N Culliton
- Orthopaedic Biomechanics Laboratory, Division of Orthopaedic Surgery, The Ottawa Hospital Research Institute, Civic Campus, Ottawa, Ontario, Canada
| | - Paul E Beaulé
- Division of Orthopaedic Surgery, The Ottawa Hospital, General Campus, Ottawa, Ontario, Canada; Faculty of Medicine, The University of Ottawa, Ottawa, Ontario, Canada
| |
Collapse
|
12
|
Roy ME, Whiteside LA, Sebastian AM. Retrieved Magnesia-Stabilized Zirconia Femoral Heads Exhibit Minimal Roughening and Abrasive Potential. J Arthroplasty 2017; 32:3806-3814. [PMID: 28844627 DOI: 10.1016/j.arth.2017.07.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2017] [Revised: 06/20/2017] [Accepted: 07/13/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The degradation of ceramic femoral heads made of yttria-stabilized zirconia (Y-TZP) because of tetragonal-to-monoclinic phase transformation in vivo is well-described, whereas magnesia-stabilized zirconia (Mg-PSZ) ceramics resist phase transformation in a warm aqueous environment. The purpose of this study was to evaluate phase transformation, changes in surface topography, and roughness parameters, including changes in surface polarity and abrasiveness, among retrieved zirconia femoral heads. METHODS A total of 69 Y-TZP and 86 Mg-PSZ-retrieved femoral heads were examined, with 5 never-implanted heads of each type as controls. Selected heads were scanned by x-ray diffraction, to measure % monoclinic phase. All heads were scanned by optical profilometry to find visual evidence of degradation and to measure surface roughness, surface polarity, and the functional roughness parameters. Monoclinic phase % and roughness data were plotted vs time in vivo. RESULTS Visual evidence of phase transformation was observed among Y-TZP femoral heads, and some exhibited pitting. Y-TZP femoral heads roughened and become more abrasive in vivo, although those made by CeramTec exhibited less degradation than those by Morgan and Saint Gobain. In contrast, Mg-PSZ heads did not exhibit pitting, undergo phase transformation, or roughen in vivo, and retained a negative surface polarity. CONCLUSION All Y-TZP femoral heads exhibited increased phase transformation with time in vivo, although not all Y-TZP heads exhibited catastrophic roughening. No phase transformation was observed on Mg-PSZ femoral heads after up to 19.2 years in vivo. The lack of degradation among Mg-PSZ retrievals suggests a lower wear potential in joint replacement.
Collapse
Affiliation(s)
- Marie E Roy
- Missouri Bone & Joint Research Foundation, St. Louis, Missouri
| | - Leo A Whiteside
- Missouri Bone & Joint Research Foundation, St. Louis, Missouri; Signal Medical Corporation, Marysville, Michigan
| | - Arun M Sebastian
- Missouri Bone & Joint Research Foundation, St. Louis, Missouri; Brainlab, Inc, Westchester, Illinois
| |
Collapse
|
13
|
Yamamoto K, Tateiwa T, Takahashi Y. Vitamin E-stabilized highly crosslinked polyethylenes: The role and effectiveness in total hip arthroplasty. J Orthop Sci 2017; 22:384-390. [PMID: 28209339 DOI: 10.1016/j.jos.2017.01.012] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2016] [Revised: 12/15/2016] [Accepted: 01/19/2017] [Indexed: 02/09/2023]
Abstract
Morphology and design of ultra-high molecular weight polyethylene (UHMWPE or simply PE) acetabular components used in total hip arthroplasty (THA) have been evolving for more than half a century. Since the late-1990s, there were two major technological innovations in PE emerged from necessity to overcome the wear-induced periprosthetic osteolysis, i.e., the development of highly crosslinked PEs (HXLPEs). There are many literature reporting that radiation crosslinked and remelted/annealed (first-generation) HXLPEs markedly reduced the incidence of osteolysis and aseptic loosening. Regardless of such clinical success in the first-generation technologies, there were some recent shifts in Japan toward the use of new second-generation HXLPEs subjected to sequential irradiation/annealing or antioxidant vitamin E (α-tocopherol) incorporation. Although the selection rate of first-generation liners still account for more than half of all the PE THAs (∼58% in 2015), the use of vitamin E-stabilized liners has been steadily growing each year since their clinical introduction in 2010. In these contexts, it is of great importance to evaluate and understand the real clinical benefits of using the new second-generation liners as compared to the first generation. This article first summarizes structural evolution and characteristic features of first-generation HXLPEs, and then provides a detailed description of second-generation antioxidant HXLPEs in regard to the role of vitamin E incorporation on their chemical and mechanical performances in THA.
Collapse
Affiliation(s)
- Kengo Yamamoto
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo 160-0023, Japan.
| | - Toshiyuki Tateiwa
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo 160-0023, Japan
| | - Yasuhito Takahashi
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo 160-0023, Japan; Department of Bone and Joint Biomaterial Research, Tokyo Medical University, 6-7-1,Nishishinjuku, Shinjuku-ku, Tokyo 160-0023, Japan.
| |
Collapse
|
14
|
Carnes KJ, Odum SM, Troyer JL, Fehring TK. Cost Analysis of Ceramic Heads in Primary Total Hip Arthroplasty. J Bone Joint Surg Am 2016; 98:1794-1800. [PMID: 27807111 DOI: 10.2106/jbjs.15.00831] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The advent of adverse local tissue reactions seen in metal-on-metal bearings, and the recent recognition of trunnionosis, have led many surgeons to recommend ceramic-on-polyethylene articulations for primary total hip arthroplasty. However, to our knowledge, there has been little research that has considered whether the increased cost of ceramic provides enough benefit over cobalt-chromium to justify its use. The primary purpose of this study was to compare the cost-effectiveness of ceramic-on-polyethylene implants and metal-on-polyethylene implants in patients undergoing total hip arthroplasty. METHODS Markov decision modeling was used to determine the ceramic-on-polyethylene implant revision rate necessary to be cost-effective compared with the revision rate of metal-on-polyethylene implants across a range of patient ages and implant costs. A different set of Markov models was used to estimate the national cost burden of choosing ceramic-on-polyethylene implants over metal-on-polyethylene implants for primary total hip arthroplasties. The Premier Research Database was used to identify 20,398 patients who in 2012 were ≥45 years of age and underwent a total hip arthroplasty with either a ceramic-on-polyethylene implant or a metal-on-polyethylene implant. RESULTS The cost-effectiveness of ceramic heads is highly dependent on the cost differential between ceramic and metal femoral heads and the age of the patient. At a cost differential of $325, ceramic-on-polyethylene bearings are cost-effective for patients <85 years of age. At a cost differential of $600, it is cost-effective to utilize ceramic-on-polyethylene bearings in patients <65 years of age, and, at a differential of $1,003, ceramic-on-polyethylene bearings are not cost-effective at any age. CONCLUSIONS The ability to recoup the initial increased expenditure of ceramic heads through a diminished lifetime revision cost is dependent on the price premium for ceramic and the age of the patient. A wholesale switch to ceramic bearings regardless of age or cost differential may result in an economic burden to the health system. LEVEL OF EVIDENCE Economic and decision analysis, Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Keith J Carnes
- College of Health and Human Services (K.J.C.) and Belk College of Business (J.L.T.), University of North Carolina at Charlotte, Charlotte, North Carolina
| | - Susan M Odum
- OrthoCarolina Research Institute, Charlotte, North Carolina
| | - Jennifer L Troyer
- College of Health and Human Services (K.J.C.) and Belk College of Business (J.L.T.), University of North Carolina at Charlotte, Charlotte, North Carolina
| | | |
Collapse
|
15
|
Yakupov RR, Sisanbaev AV, Sirodzhov KH, Khairov TE, Gafarov IR, Karimov KK, Trubin AR, Filimonov GN. Postimplantation Changes in Components of Hip Endoprostheses. BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA 2016. [DOI: 10.1007/s10527-016-9587-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
16
|
Hamai S, Nakashima Y, Mashima N, Yamamoto T, Kamada T, Motomura G, Imai H, Fukushi JI, Miura H, Iwamoto Y. Comparison of 10-year clinical wear of annealed and remelted highly cross-linked polyethylene: A propensity-matched cohort study. J Mech Behav Biomed Mater 2015; 59:99-107. [PMID: 26751705 DOI: 10.1016/j.jmbbm.2015.12.022] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2015] [Revised: 12/15/2015] [Accepted: 12/17/2015] [Indexed: 10/22/2022]
Abstract
No previous studies comparing the clinical wear rates of the two different kinds of cross-linked ultra-high-molecular-weight polyethylene (XLPE), annealed and remelted, are available. We compared the creep and steady wear rates of 36 matched pairs (72 hips in total) adjusting for baseline characteristics with propensity score matching techniques. Zirconia femoral heads with 26-mm diameter were used in all cases. The femoral-head cup penetration was measured digitally on radiographs. Significantly greater creep (p=0.006) was detected in the remelted (0.234mm) than annealed (0.159mm) XLPE. However, no significant difference (p=0.19) was found between the steady wear rates (0.003 and 0.008mm/year, respectively) of the annealed and remelted XLPE. Multiple regression analyses showed that remelted XLPE is significant independent variable (p<0.001) that is positively associated with creep. However, the patient age and body weight, cup size, the liner thickness, cup inclination, follow-up periods, and postoperative Merle d'Aubigné hip score had no significant effects (p>0.05) on the steady wear rates. No patients exhibited above the osteolysis threshold of 0.1mm/year, progressive radiolucencies, osteolysis, or polyethylene fracture. This propensity-matched cohort study document no significant difference in wear resistant performances of annealed and remelted XLPE over an average period of 10 years.
Collapse
Affiliation(s)
- Satoshi Hamai
- Department of Orthopaedic Surgery, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan; Department of Artificial Joints and Biomaterials, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Yasuharu Nakashima
- Department of Orthopaedic Surgery, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
| | - Naohiko Mashima
- Department of Bone and Joint Surgery, Graduate School of Medicine, Ehime University, Shitsukawa, Toon, Ehime 791-0295, Japan
| | - Takuaki Yamamoto
- Department of Orthopaedic Surgery, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Tomomi Kamada
- Department of Bone and Joint Surgery, Graduate School of Medicine, Ehime University, Shitsukawa, Toon, Ehime 791-0295, Japan
| | - Goro Motomura
- Department of Orthopaedic Surgery, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Hiroshi Imai
- Department of Bone and Joint Surgery, Graduate School of Medicine, Ehime University, Shitsukawa, Toon, Ehime 791-0295, Japan
| | - Jun-Ichi Fukushi
- Department of Orthopaedic Surgery, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Hiromasa Miura
- Department of Bone and Joint Surgery, Graduate School of Medicine, Ehime University, Shitsukawa, Toon, Ehime 791-0295, Japan
| | - Yukihide Iwamoto
- Department of Orthopaedic Surgery, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| |
Collapse
|
17
|
Karidakis GK, Karachalios T. Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study. Clin Orthop Relat Res 2015; 473:3836-45. [PMID: 26290343 PMCID: PMC4626474 DOI: 10.1007/s11999-015-4503-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Osteolysis resulting from wear debris production from the bearing surfaces is a major factor limiting long-term survival of hip implants. Oxidized zirconium head on crosslinked polyethylene (XLPE) is a modern bearing coupling. However, midterm in vivo wear data of this coupling are not known. QUESTIONS/PURPOSES The purpose of this study was to investigate in vivo whether the combination of an oxidized zirconium femoral head on XLPE produces less wear than a ceramic head on XLPE or a ceramic head on conventional polyethylene (CPE) couplings and whether any of these bearing combinations results in higher hip scores. METHODS Between 2003 and 2007, we performed 356 total hip arthroplasties in 288 patients; of those, 199 (69.1%) patients (199 hips) were enrolled in what began as a randomized trial. Unfortunately, after the 57(th) patient, the randomization process was halted because of patients' preference for the oxidized zirconium bearing instead of the ceramic after (as they were informed by the consent form), and after that, alternate allocation to the study groups was performed. Hips were allocated into four groups: in Group A, a 28-mm ceramic head on CPE was used; in Group B, a 28-mm ceramic head on XLPE; in Group C, a 28-mm Oxinium head on XLPE; and in Group D, a 32-mm Oxinium head on XLPE. The authors prospectively collected in vivo wear data (linear wear, linear wear rate, volumetric wear, and volumetric wear rate) using PolyWare software. Preoperative and postoperative clinical data, including Harris and Oxford hip scores, were also collected at regular intervals. Of those patients enrolled, 188 (95%) were available for final followup at a minimum of 7 years (mean, 9 years; range, 7-12 years). RESULTS All bearing surfaces showed a varying high bedding-in effect (plastic deformation of the liner) up to the second postoperative year. At 5 years both oxidized zirconium on XLPE groups showed lower (p < 0.01) volumetric wear (mean ± SD mm(3)) and volumetric wear rates (mean ± SD mm(3)/year) (Group C: 310 ± 55-206 ± 55 mm(3)/year, Group D: 320 ± 58-205 ± 61 mm(3)/year) when compared with ceramic on CPE (Group A: 791 ± 124-306 ± 85 mm(3)/year) and ceramic on XLPE (Group B: 1420 ± 223-366 ± 88 mm(3)/year) groups. For those patients who had completed 10 years of followup (20 patients [44.5%] of Group A, 21 [45.7%] of Group B, 23 [47.9%] of Group C, and 22 [44.9%] of Group D), at 10 years, both oxidized zirconium on XLPE groups also showed lower (p < 0.01) volumetric wear (mean ± SD mm(3)) and volumetric wear rates (mean ± SD mm(3)/year) (Group C: 356 ± 64 to 215 ± 54 mm(3)/year, Group D: 354 ± 50 to 210 ± 64 mm(3)/year) when compared with ceramic on CPE (Group A: 895 ± 131 to 380 ± 80 mm(3)/year) and ceramic on XLPE (Group B: 1625 ± 253 to 480 ± 101 mm(3)/year) groups. When wear rates of both oxidized zirconium groups were compared, no differences were found at any time interval with the numbers available. Two hips (one from Group A and one from Group B) are scheduled for revision as a result of wear and osteolysis. There were no differences in hip scores among the groups with the numbers available. CONCLUSIONS In this study, in vivo wear parameters were lower when the combination of an oxidized zirconium head on XLPE liner was used at an average of 9 years (range, 7-12 years) followup. Further larger-scale clinical studies should confirm these findings and evaluate osteolysis and revision rates in association with the use of this bearing coupling. LEVEL OF EVIDENCE Level II, therapeutic study.
Collapse
Affiliation(s)
- George K. Karidakis
- Orthopaedic Department, Faculty of Medicine, School of Health Sciences, University of Thessalia, University General Hospital of Larissa, Larissa, Hellenic Republic
| | - Theofilos Karachalios
- Orthopaedic Department, Faculty of Medicine, School of Health Sciences, University of Thessalia, University General Hospital of Larissa, Larissa, Hellenic Republic
| |
Collapse
|
18
|
The case for ceramic-on-polyethylene as the preferred bearing for a young adult hip replacement. Hip Int 2015; 24:421-7. [PMID: 24817396 DOI: 10.5301/hipint.5000138] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 02/03/2014] [Indexed: 02/04/2023]
Abstract
The optimum choice of bearing surfaces in total hip arthroplasty, particularly in the younger and more active patient, remains controversial. Despite several studies demonstrating good long-term results for the metal-on-polyethylene articulation, there has been a recent vogue towards the utilisation of hard-on-hard bearings for younger patients due, in part, to concerns regarding polyethylene induced osteolysis. However, well-documented complications concerning metal-on-metal bearings and the risk of fracture in ceramic-on-ceramic bearings have raised concerns regarding the principle of the hard-on-hard bearing in the active patient. With recent technological advancements in the manufacture of both polyethylene and alumina ceramics, the in vitro properties of each material with regards to strength and toughness have been significantly improved. In addition, ceramic femoral heads have consistently been shown to produce less in vivo polyethylene wear than similar sized metal heads. This paper aims to critically review the biomechanical, in vivo and clinical studies related to the use of the ceramic on polyethylene bearing, and highlights its potential use as the preferred bearing for a young adult hip replacement.
Collapse
|
19
|
Inokoshi M, Vanmeensel K, Zhang F, De Munck J, Eliades G, Minakuchi S, Naert I, Van Meerbeek B, Vleugels J. Aging resistance of surface-treated dental zirconia. Dent Mater 2015; 31:182-94. [PMID: 25572860 DOI: 10.1016/j.dental.2014.11.018] [Citation(s) in RCA: 88] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2014] [Revised: 07/19/2014] [Accepted: 11/28/2014] [Indexed: 02/01/2023]
Abstract
UNLABELLED The influence of surface treatment on the low-temperature degradation (LTD) of tetragonal zirconia polycrystalline (TZP) is still unclear. OBJECTIVES The effect of surface treatments on the LTD behavior of zirconia was investigated. METHODS Fully-sintered specimens of seven commercial dental zirconia (Aadva, GC; In-CeramYZ, VITA; IPS e.max ZirCAD, Ivoclar Vivadent; LAVA Frame and LAVA Plus, 3M ESPE; NANOZR, Panasonic; ZirTough, Kuraray Noritake) were provided by the manufacturers with specimen dimensions of approximately 10mm×5mm×3mm. For each zirconia grade, samples were kept 'as sintered' (untreated) or were subjected to one of the three surface treatments: rough polished, sandblasted with Al2O3, tribochemical silica sandblasted (n=3/group). The tetragonal to monoclinic transformation was evaluated by X-ray diffraction at several intervals during LTD testing up to 40h in steam in an autoclave (134°C, 2bar). RESULTS The five yttria-stabilized TZP (Y-TZP: Aadva, In-CeramYZ, IPS e.max ZirCAD, LAVA Frame, LAVA Plus) zirconia showed a similar trend in LTD behavior. The Al2O3 sandblasted zirconia showed the highest monoclinic volume fraction. The as sintered (untreated) zirconia degraded faster than the surface-treated zirconia. Although the surface-treated ceria-stabilized TZP/alumina (Ce-TZP/Al2O3: NANOZR) zirconia had a higher initial monoclinic volume fraction compared to the Y-TZP zirconia, it showed a stronger aging resistance. The as sintered (untreated) Y-TZP/alumina (Y-TZP/Al2O3: ZirTough) zirconia showed a strong aging resistance, whereas the surface-treated Y-TZP/Al2O3 zirconia degraded slightly. SIGNIFICANCE Surface treatment improved the aging resistance of Y-TZP zirconia. Surface treatment did not affect the LTD behavior of Ce-TZP/Al2O3 zirconia, while surface treatment decreased the aging resistance of Y-TZP/Al2O3 zirconia.
Collapse
Affiliation(s)
- Masanao Inokoshi
- KU Leuven BIOMAT, Department of Oral Health Sciences, KU Leuven (University of Leuven) & Dentistry, University Hospitals Leuven, Kapucijnenvoer 7, blok a bus 7001, B-3000 Leuven, Belgium
| | - Kim Vanmeensel
- Department of Materials Engineering, KU Leuven (University of Leuven), Kasteelpark Arenberg 44, B-3001 Heverlee, Belgium
| | - Fei Zhang
- Department of Materials Engineering, KU Leuven (University of Leuven), Kasteelpark Arenberg 44, B-3001 Heverlee, Belgium
| | - Jan De Munck
- KU Leuven BIOMAT, Department of Oral Health Sciences, KU Leuven (University of Leuven) & Dentistry, University Hospitals Leuven, Kapucijnenvoer 7, blok a bus 7001, B-3000 Leuven, Belgium
| | - George Eliades
- Department of Biomaterials, University of Athens, 2 Thivon Str., Goudi, 115 27 Athens, Greece
| | - Shunsuke Minakuchi
- Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo, Tokyo 113-8549, Japan
| | - Ignace Naert
- KU Leuven BIOMAT, Department of Oral Health Sciences, KU Leuven (University of Leuven) & Dentistry, University Hospitals Leuven, Kapucijnenvoer 7, blok a bus 7001, B-3000 Leuven, Belgium
| | - Bart Van Meerbeek
- KU Leuven BIOMAT, Department of Oral Health Sciences, KU Leuven (University of Leuven) & Dentistry, University Hospitals Leuven, Kapucijnenvoer 7, blok a bus 7001, B-3000 Leuven, Belgium.
| | - Jozef Vleugels
- Department of Materials Engineering, KU Leuven (University of Leuven), Kasteelpark Arenberg 44, B-3001 Heverlee, Belgium
| |
Collapse
|
20
|
Inokoshi M, Zhang F, De Munck J, Minakuchi S, Naert I, Vleugels J, Van Meerbeek B, Vanmeensel K. Influence of sintering conditions on low-temperature degradation of dental zirconia. Dent Mater 2014; 30:669-78. [DOI: 10.1016/j.dental.2014.03.005] [Citation(s) in RCA: 68] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2013] [Revised: 02/25/2014] [Accepted: 03/07/2014] [Indexed: 10/25/2022]
|
21
|
Ast MP, John TK, Labbisiere A, Robador N, Valle AGD. Fractures of a single design of highly cross-linked polyethylene acetabular liners: an analysis of voluntary reports to the United States Food and Drug Administration. J Arthroplasty 2014; 29:1231-5. [PMID: 24444569 DOI: 10.1016/j.arth.2013.12.022] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2013] [Revised: 12/03/2013] [Accepted: 12/13/2013] [Indexed: 02/01/2023] Open
Abstract
Polyethylene liner fracture is a risk associated with the use of highly cross-linked UHMWPE. We performed a review of the voluntary reports of fractured liners to the US Food and Drug Administration to determine if any risk factors could be identified. There have been 74 reports of fractured Trilogy, Longevity liners to the US Food and Drug Administration since 1999. Most cases utilized small acetabular shells (≤54 mm) combined with large diameter heads (≥36 mm). Liners less than 7 mm thick at the weight bearing or 4.8 mm thick at the rim should be used with caution. At revision surgery, malpositioned shells should be revised and the use of a thin liner should be avoided.
Collapse
Affiliation(s)
- Michael P Ast
- Department of Orthopaedic Surgery, Division of Adult Reconstruction and Joint Replacement Surgery, Hospital for Special Surgery, New York, New York
| | - Thomas K John
- Department of Orthopaedic Surgery, Division of Adult Reconstruction and Joint Replacement Surgery, Hospital for Special Surgery, New York, New York
| | - Anthony Labbisiere
- Department of Orthopaedic Surgery, Division of Adult Reconstruction and Joint Replacement Surgery, Hospital for Special Surgery, New York, New York
| | - Nicolas Robador
- Department of Orthopaedic Surgery, Division of Adult Reconstruction and Joint Replacement Surgery, Hospital for Special Surgery, New York, New York
| | - Alejandro Gonzalez Della Valle
- Department of Orthopaedic Surgery, Division of Adult Reconstruction and Joint Replacement Surgery, Hospital for Special Surgery, New York, New York
| |
Collapse
|
22
|
Abstract
Large ceramic femoral heads offer several advantages that are potentially advantageous to patients undergoing both primary and revision total hip replacement. Many high-quality studies have demonstrated the benefit of large femoral heads in reducing post-operative instability. Ceramic femoral heads may also offer an advantage in reducing polyethylene wear that has been reported in vitro and is starting to become clinically apparent in mid-term clinical outcome studies. Additionally, the risk of taper corrosion at a ceramic femoral head-neck junction is clearly lower than when using a metal femoral head. With improvements in the material properties of both modern ceramic femoral heads and polyethylene acetabular liners that have reduced the risk of mechanical complications, large ceramic heads have gained popularity in recent years.
Collapse
Affiliation(s)
- J A Rodriguez
- Department of Orthopaedic Surgery, Lenox Hill Hospital, 130 East 77th Street, 11th Floor, New York, New York 10075, USA
| | | |
Collapse
|
23
|
Abstract
BACKGROUND Jogging has been classified as a high-impact sport, and jogging after total hip arthroplasty (THA) has not been well documented. PURPOSE To investigate the participation rate for postoperative jogging as well as jogging parameters and the influence of jogging on implant stability and bearing wear. STUDY DESIGN Case-control study; Level of evidence, 3. METHODS Included in this study were 804 hips in 608 patients (85 men, 523 women) who underwent THA between 2005 and 2011 with follow-up longer than 1 year. The mean patient age was 62 years (range, 26-98 years), and mean follow-up duration was 4.8 years (range, 2.3-7.8 years). Hip resurfacing arthroplasty (HRA) was performed in 81 patients and conventional THA in 527 patients. During routine postsurgical visits, patients were given a questionnaire concerning preoperative and postoperative jogging routines. For joggers, frequency, distance, duration, and velocity of jogging were recorded. Patients who did not jog postoperatively were asked to provide reasons for not jogging. Radiographs concerning implant migration and polyethylene wear were evaluated with specialized software, and serum cobalt and chromium ion concentrations were investigated for patients with metal-on-metal articulation. RESULTS A total of 33 patients (5.4%) performed jogging preoperatively, and 23 patients (3.8%) performed jogging postoperatively. Of the 23 who jogged postoperatively, conventional THA was performed in 13 patients and HRA in 10 patients. Postoperatively, joggers trained a mean of 4 times (range, 1-7 times) per week, covering a mean distance of 3.6 km (range, 0.5-15 km) in a mean time of 29 minutes (range, 5-90 minutes) per session and at a mean speed of 7.7 km/h (range, 3-18 km/h). No patient complained of pain or showed serum cobalt and chromium ion elevation greater than 7 ppb. No hip showed loosening, abnormal component migration, or excessive wear at a mean 5-year follow-up. There were 74 postoperative non-joggers with an interest in jogging. The reasons given for avoiding jogging included anxiety (45 patients; 61%); impossible because of several reasons, including pain, decreased range of motion, and muscle weakness (18 patients; 24%); and lumbar or knee pain (11 patients; 15%). Multivariate analysis revealed that male sex and a history of preoperative jogging demonstrated significant relationships with postoperative jogging. CONCLUSION A total of 3.8% of THA patients participated in postoperative jogging. Short-term postoperative follow-up did not identify any negative influence of jogging on implant survival.
Collapse
Affiliation(s)
- Hirohito Abe
- Takashi Sakai, Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, 565-0871, Japan.
| | | | | | | | | | | |
Collapse
|
24
|
Fukui K, Kaneuji A, Sugimori T, Ichiseki T, Matsumoto T. Wear comparison between conventional and highly cross-linked polyethylene against a zirconia head: a concise follow-up, at an average 10 years, of a previous report. J Arthroplasty 2013; 28:1654-8. [PMID: 23523499 DOI: 10.1016/j.arth.2012.12.020] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2012] [Revised: 12/28/2012] [Accepted: 12/29/2012] [Indexed: 02/01/2023] Open
Abstract
We previously reported the results of wear comparison at a minimum of 5 years between highly cross-linked polyethylene (HXLPE) and conventional polyethylene (PE) against a zirconia femoral head. We now report the mean wear at 10 years for 52 patients (56 hips) of the original cohort of 61 patients (65 hips) who had undergone primary total hip arthroplasty at our hospital between November 1999 and August 2000. The mean steady-state linear wear rate of HXLPE was 0.045 mm/y, compared with 0.080 mm/y for conventional PE (P=.0003). The incidence of osteolysis was 25% in the conventional PE group compared with 0% in the HXLPE group. Our study demonstrated that the steady-state wear rate for HXLPE remains significantly lower than that for conventional PE against a zirconia femoral head at a mean of 10 years after implantation.
Collapse
Affiliation(s)
- Kiyokazu Fukui
- Department of Orthopaedic Surgery, Kanazawa Medical University, Kahokugun, Ishikawa, Japan
| | | | | | | | | |
Collapse
|
25
|
Hasegawa M, Sudo A. In vivo wear performance of highly cross-linked polyethylene vs. yttria stabilized zirconia and alumina stabilized zirconia at a mean seven-year follow-up. BMC Musculoskelet Disord 2013; 14:154. [PMID: 23634809 PMCID: PMC3646672 DOI: 10.1186/1471-2474-14-154] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2012] [Accepted: 04/23/2013] [Indexed: 11/24/2022] Open
Abstract
Background Zirconia was introduced as an alternative to alumina for use in the femoral head. The yttria stabilized zirconia material was improved by adding alumina. We evaluated highly cross-linked polyethylene wear performance of zirconia in total hip arthroplasty. The hypothesis was that alumina stabilized zirconia could decrease highly cross-linked polyethylene wear. Methods Highly cross-linked polyethylene wear was measured with a computerized method (PolyWare) in 91 hips. The steady-state wear rates were measured based on the radiographs from the first year postoperatively to the final follow-up and were compared between hips with yttria stabilized zirconia and alumina stabilized zirconia. Results The steady-state wear rate of highly cross-linked polyethylene against zirconia was 0.02 mm/year at a mean follow-up of 7 years. No significant difference was observed between groups with yttria stabilized zirconia and alumina stabilized zirconia. Conclusions Addition of alumina to the zirconia material failed to show further reduction of highly cross-linked polyethylene wear and our hypothesis was not verified.
Collapse
Affiliation(s)
- Masahiro Hasegawa
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu City Mie 514-8507, Japan.
| | | |
Collapse
|
26
|
Comparison of conventional polyethylene wear and signs of cup failure in two similar total hip designs. Adv Orthop 2013; 2013:710621. [PMID: 23662210 PMCID: PMC3639702 DOI: 10.1155/2013/710621] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2013] [Revised: 03/06/2013] [Accepted: 03/06/2013] [Indexed: 11/17/2022] Open
Abstract
Multiple factors have been identified as contributing to polyethylene wear and debris generation of the acetabular lining. Polyethylene wear is the primary limiting factor in the functional behavior and consequent longevity of a total hip arthroplasty (THA). This retrospective study reviewed the clinical and radiographic data of 77 consecutive THAs comparing in vivo polyethylene wear of two similar acetabular cup liners. Minimum follow-up was 7 years (range 7-15). The incidence of measurable wear in a group of machined liners sterilized with ethylene oxide and composed of GUR 1050 stock resin was significantly higher (61%) than the compression-molded, GUR 1020, O2-free gamma irradiation sterilized group (24%) (P = 0.0004). Clinically, at a 9-year average followup, both groups had comparable HHS scores and incidence of thigh or groin pain, though the machined group had an increased incidence of osteolysis and annual linear wear rate.
Collapse
|
27
|
Oonishi H, Kyomoto M, Iwamoto M, Ueno M, Oonishi H. Radiographic and retrieval wear analyses of the first generation highly cross-linked polyethylene cup against a ceramic femoral head. J Biomed Mater Res B Appl Biomater 2013; 101:1594-601. [PMID: 23564746 DOI: 10.1002/jbm.b.32929] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2012] [Revised: 01/03/2013] [Accepted: 02/17/2013] [Indexed: 11/10/2022]
Abstract
In this study, the in vivo wear of highly cross-linked polyethylene (CLPE) cups against alumina ceramic femoral heads was evaluated by radiographic and retrieval analysis. The radiographic wear of six ethylene oxide gas-sterilized (i.e., non-cross-linked) conventional polyethylene (PE) cups with the mean follow-up of 20.9 years and 60 CLPE cups with the mean follow-up of 7.4 years was measured. The retrieved 16 PE cups with clinical use for mean 21.5 years and 10 CLPE cups with clinical use for mean 2.9 years was evaluated as a retrieval analysis. In the radiographic analysis, the linear wear of CLPE cups was significantly lower (99% reduction) compared to conventional polyethylene cups. The results of retrieval analyses for both cups were similar to those of radiographic analyses. Even when third-body wear occurred during clinical use, no surface damage was observed on the surface of ceramic femoral heads. The surface is not sensitive to third-body wear, and hence, the ceramic femoral head has a great advantage in terms of the wear of CLPE under third-body wear conditions. In conclusion, CLPE cups used with alumina ceramic femoral heads in total hip arthroplasty should have favorable wear resistance in several in vivo situations.
Collapse
Affiliation(s)
- Hiroyuki Oonishi
- H. Oonishi Memorial Joint Replacement Institute, Tominaga Hospital, Osaka, Japan
| | | | | | | | | |
Collapse
|
28
|
Charnley-Kerboull total hip arthroplasty combining zirconia on polyethylene. A minimum eight-year follow-up prospective study. INTERNATIONAL ORTHOPAEDICS 2013; 37:355-60. [PMID: 23371426 DOI: 10.1007/s00264-013-1792-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2013] [Accepted: 01/10/2013] [Indexed: 10/27/2022]
Abstract
PURPOSE Zirconia was introduced in the 1980s for total hip arthroplasty (THA) with the expectation of lower polyethylene wear. The purpose of this prospective study was to evaluate the results of a continuous series of total hip arthroplasties combining a zirconia head with polyethylene socket at a minimum eight-year follow-up. METHODS We performed an open prospective clinical trial in 1997. Our study involved 51 consecutive patients (55 hips) with a mean age of 52.5 ± 12 years (range, 25-76 years). All patients had a Charnley-Kerboull all-cemented hip replacement. A 22-mm stabilised yttrium tetragonal polycrystalline zirconia head (Y-TZP) was used in association with moderately cross-linked and annealed polyethylene. Clinical and radiological outcomes were assessed yearly. A survival analysis was performed using revision for any reason as the end-point. RESULTS At a minimum eight-year follow-up, 12 patients (13 hips) were lost to follow-up (mean 26.8 months), two patients (two hips) had died, and six patients (six hips) were revised. The remaining 31 patients (34 hips) were alive and had not been revised on either the femoral or acetabular side at a mean follow-up of 117.1 months (range, 96-150 months). Mean functional score at last follow-up was 17.7. Mean linear head penetration was 0.23 mm/year. More than 90% of the remaining hips had signs of periprosthetic osteolysis. Five stems were loosened. The survival at eight years was 87.3% (95% IC: 76.7-97.8). CONCLUSION This study confirms earlier short-terms results, and demonstrates that zirconia should no longer be used in THA.
Collapse
|
29
|
Sato T, Nakashima Y, Akiyama M, Yamamoto T, Mawatari T, Itokawa T, Ohishi M, Motomura G, Hirata M, Iwamoto Y. Wear resistant performance of highly cross-linked and annealed ultra-high molecular weight polyethylene against ceramic heads in total hip arthroplasty. J Orthop Res 2012; 30:2031-7. [PMID: 22644564 DOI: 10.1002/jor.22148] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2012] [Accepted: 05/01/2012] [Indexed: 02/04/2023]
Abstract
The purpose of this study was to examine the effects of ceramic femoral head material, size, and implantation periods on the wear of annealed, cross-linked ultra-high molecular weight polyethylene (UHMWPE) (XLPE) in total hip arthroplasty compared to non-cross-linked conventional UHMWPE (CPE). XLPE was fabricated by cross-linking with 60 kGy irradiation and annealing. Femoral heads made from zirconia and alumina ceramics and cobalt-chrome (CoCr) of 22 or 26 mm diameter were used. In this retrospective cohort study, the femoral head penetration into the cup was measured digitally on radiographs of 367 hips with XLPE and 64 hips with CPE. The average follow-up periods were 6.3 and 11.9 years, respectively. Both XLPE creep and wear rates were significantly lower than those of CPE (0.19 mm vs. 0.44 mm, 0.0001 mm/year vs. 0.09 mm/year, respectively). Zirconia displayed increased wear rates compared to alumina in CPE; however, there was no difference among head materials in XLPE (0.0008, 0.00007, and -0.009 mm/year for zirconia, alumina, and CoCr, respectively). Neither head size or implantation period impacted XLPE wear. In contrast to CPE, XLPE displayed low wear rates surpassing the effects of varying femoral head material, size, implantation period, and patient demographics. Further follow-up is required to determine the long-term clinical performance of the annealed XLPE.
Collapse
Affiliation(s)
- Taishi Sato
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Bal BS, Rahaman MN. Orthopedic applications of silicon nitride ceramics. Acta Biomater 2012; 8:2889-98. [PMID: 22542731 DOI: 10.1016/j.actbio.2012.04.031] [Citation(s) in RCA: 99] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2012] [Revised: 04/18/2012] [Accepted: 04/19/2012] [Indexed: 11/29/2022]
Abstract
Silicon nitride (Si(3)N(4)) is a ceramic material developed for industrial applications that demand high strength and fracture resistance under extreme operating conditions. Recently, Si(3)N(4) has been used as an orthopedic biomaterial, to promote bone fusion in spinal surgery and to develop bearings that can improve the wear and longevity of prosthetic hip and knee joints. Si(3)N(4) has been implanted in human patients for over 3 years now, and clinical trials with Si(3)N(4) femoral heads in prosthetic hip replacement are contemplated. This review will provide background information and data relating to Si(3)N(4) ceramics that will be of interest to engineering and medical professionals.
Collapse
Affiliation(s)
- B S Bal
- Department of Orthopaedic Surgery, School of Medicine, University of Missouri, Columbia, MO 65211, USA.
| | | |
Collapse
|
31
|
Characterization of alendronate sodium-loaded UHMWPE for anti-osteolysis in orthopedic applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2012. [DOI: 10.1016/j.msec.2011.09.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
32
|
Nakahara I, Nakamura N, Takao M, Sakai T, Nishii T, Sugano N. Eight-year wear analysis in Longevity highly cross-linked polyethylene liners comparing 26- and 32-mm heads. Arch Orthop Trauma Surg 2011; 131:1731-7. [PMID: 21814775 DOI: 10.1007/s00402-011-1360-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/06/2010] [Indexed: 02/09/2023]
Abstract
INTRODUCTION Although wear reduction of highly cross-linked polyethylene has been demonstrated to be independent of femoral head diameter in some simulation studies, the clinical effects of femoral head diameter on wear of highly cross-linked polyethylene sockets remain unclear. We compared the in vivo wear of Longevity highly cross-linked polyethylene liners at 8-year follow-up using 26- or 32-mm cobalt-chromium heads. MATERIALS AND METHODS A retrospective cohort study was performed on 90 cementless total hip arthroplasties (THAs) using Longevity highly cross-linked polyethylene liners combined with 26- (45 THAs) or 32-mm (45 THAs) cobalt-chromium heads. Annual radiographs were analyzed using PolyWare computer-assisted methods and linear and volumetric total head penetration rates and linear and volumetric steady-state wear rates were compared. RESULTS The two groups showed similar background data, and no significant differences were identified between groups in total head penetration rate or steady-state wear rate. Steady-state wear rates were negligible. Osteolysis was not observed in any hips in either group. CONCLUSIONS At the 8-year follow-up, wear of the Longevity was the same irrespective of the use 26- or 32-mm heads.
Collapse
Affiliation(s)
- Ichiro Nakahara
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| | | | | | | | | | | |
Collapse
|
33
|
Midterm results of primary total hip arthroplasty using highly cross-linked polyethylene: minimum 7-year follow-up study. J Arthroplasty 2011; 26:1014-9. [PMID: 21621960 DOI: 10.1016/j.arth.2011.03.015] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2011] [Accepted: 03/07/2011] [Indexed: 02/01/2023] Open
Abstract
The purpose of this study was to investigate the results of 113 total hip arthroplasties in 109 patients using highly cross-linked polyethylene (HXLPE) after midterm (minimum 7 years) follow-up retrospectively. The mean age at the time of operation was 57 years. Preoperative diagnosis was osteonecrosis in 81 hips and other diagnosis in 32 hips. There was no component loosening. Acetabular osteolysis was found in 12 hips (10.6 %). Mean linear HXLPE wear rate was 0.031 ± 0.012 mm/y. We analyzed the relationship between HXLPE wear rate and several variables influencing HXLPE wear. Only the cup position was related with wear rate of HXLPE significantly (P < .05). The results of total hip arthroplasties using HXLPE showed excellent results with decreased wear rate and low incidence of osteolysis after midterm follow-up.
Collapse
|
34
|
Roy ME, Whiteside LA, Magill ME, Katerberg BJ. Reduced wear of cross-linked UHMWPE using magnesia-stabilized zirconia femoral heads in a hip simulator. Clin Orthop Relat Res 2011; 469:2337-45. [PMID: 21312076 PMCID: PMC3126965 DOI: 10.1007/s11999-011-1800-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2010] [Accepted: 01/26/2011] [Indexed: 01/31/2023]
Abstract
BACKGROUND To reduce wear, the ideal bearing surface in joint arthroplasty should be smooth and hydrophilic. Ceramics generally offer better wettability than metals and can be polished to a smoother finish. However, clinical studies have found no reduction in liner wear when using yttria-stabilized zirconia (Y-TZP) instead of cobalt chromium alloy (CoCr) femoral heads. QUESTION/PURPOSES We (1) determined whether a hard, diamond-like carbon (DLC) coating would enhance the wettability of CoCr and magnesia-stabilized zirconia (Mg-PSZ) femoral heads without increasing roughness, and (2) compared their wear performance. METHODS In an observational study limited to CoCr and Mg-PSZ heads, we measured roughness and contact angle on as-received and DLC-coated heads. Eight heads then were subjected to 11 million cycles of wear in a hip simulator against cross-linked ultrahigh molecular weight polyethylene (XLPE) liners. RESULTS Mg-PSZ femoral heads were smoother and more hydrophilic than CoCr heads. Although DLC coatings did not reduce roughness, they reduced the contact angle of CoCr and Mg-PSZ substrates, which may provide enhanced lubrication in vivo. In hip simulator tests, liners bearing against CoCr heads wore at a greater rate compared with Mg-PSZ heads. The DLC coating on Mg-PSZ heads did not reduce wear further. CONCLUSIONS The wear rate of XLPE versus Mg-PSZ was seven times less than CoCr heads, probably owing to lower roughness and greater wettability of Mg-PSZ heads. CLINICAL RELEVANCE The use of Mg-PSZ femoral heads should lead to reduced wear in vivo compared with CoCr heads, but the clinical benefit of DLC-coated Mg-PSZ is unclear.
Collapse
Affiliation(s)
- Marcel E. Roy
- Missouri Bone & Joint Research Foundation, 1000 Des Peres Rd., Suite 150, St. Louis, MO 63131 USA
| | - Leo A. Whiteside
- Missouri Bone & Joint Research Foundation, 1000 Des Peres Rd., Suite 150, St. Louis, MO 63131 USA ,Signal Medical Corp, St. Louis, MO USA
| | | | | |
Collapse
|
35
|
Kurtz SM, Gawel HA, Patel JD. History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene. Clin Orthop Relat Res 2011; 469:2262-77. [PMID: 21431461 PMCID: PMC3126942 DOI: 10.1007/s11999-011-1872-4] [Citation(s) in RCA: 313] [Impact Index Per Article: 24.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Highly crosslinked polyethylene (HXLPE) was introduced to reduce wear and osteolysis in total joint arthroplasty. While many studies report wear and osteolysis associated with HXLPE, analytical techniques, clinical study design and followup, HXLPE formulation and implant design characteristics, and patient populations differ substantially among investigations, complicating a unified perspective. QUESTIONS/PURPOSES Literature on first-generation HXLPE was summarized. We systematically reviewed the radiographic wear data and incidence of osteolysis for HXLPE in hip and knee arthroplasty. METHODS PubMed identified 391 studies; 28 met inclusion criteria for a weighted-averages analysis of two-dimensional femoral head penetration rates. To determine the incidence of osteolysis, we estimated a pooled odds ratio using a random-effects model. RESULTS Weighted-averages analyses of femoral head penetration rates in HXLPE liners and conventional UHMWPE liners resulted, respectively, in a mean two-dimensional linear penetration rate of 0.042 mm/year based on 28 studies (n=1503 hips) and 0.137 mm/year based on 18 studies (n=695 hips). The pooled odds ratio for the risk of osteolysis in HXLPE versus conventional liners was 0.13 (95% confidence interval, 0.06-0.27) among studies with minimum 5-year followup. We identified two clinical studies of HXLPE in TKA, preventing systematic analysis of outcomes. CONCLUSIONS HXLPE liner studies consistently report lower femoral head penetration and an 87% lower risk of osteolysis. Reduction in femoral head penetration or osteolysis risk is not established for large-diameter (>32 mm) metallic femoral heads or ceramic femoral heads of any size. Few studies document the clinical performance of HXLPE in knees.
Collapse
Affiliation(s)
- Steven M Kurtz
- Exponent, Inc, 3401 Market Street, Suite 300, Philadelphia, PA 19104, USA.
| | | | | |
Collapse
|