1
|
Singh N, Awasthi A, Pisulkar G, Taywade S, Samal N. Adverse Metal Reaction in a Case of Metal-on-Polyethylene Hip Arthroplasty. Cureus 2024; 16:e60810. [PMID: 38910664 PMCID: PMC11189828 DOI: 10.7759/cureus.60810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 04/30/2024] [Indexed: 06/25/2024] Open
Abstract
Soft tissue inflammatory responses to metal debris from prostheses, categorised as adverse reactions to metal debris (ARMD), are frequent complications of total hip arthroplasty (THA) and often result in implant failure. Introducing modular implant designs in modern orthopaedics has brought benefits to total hip replacements but has also increased patients' susceptibility to corrosion-related risks. ARMD can develop from various metal articulating surfaces, including ceramic-on-polyethylene (CoP), ceramic-on-ceramic (CoC), metal-on-metal (MoM), and metal-on-polyethylene (MoP) configurations. In this case study, a 68-year-old male who underwent a MoP implant for osteoarthritis of the right hip 16 years ago presented with pain and difficulty walking, exacerbated over the past three months. Clinical examination revealed tenderness around the implant and a limited range of motion. Imaging studies, including X-rays and ultrasound-guided aspiration, coupled with normal serum and urinary cobalt (Co) and chromium (Cr) levels, confirmed the diagnosis of ARMD. Given the severity of symptoms and radiographic findings, surgical intervention was warranted, leading to a two-stage revision with implant augmentation using a Burch-Schneider cage. Three months post operation, the patient experienced significant improvements in pain levels, range of motion (ROM), and hip function. This case underscores the importance of vigilant surveillance for ARMD in patients undergoing non-MoM THA, even years post surgery. Prompt recognition and management of ARMD are crucial to mitigate the risk of long-term complications and optimise patient outcomes. Further research is needed to understand the risk factors and mechanisms underlying ARMD in MoP THA, aiding in developing preventive strategies and refined treatment protocols.
Collapse
Affiliation(s)
- Nikhil Singh
- Department of Orthopaedic Surgery, Jawaharlal Nehru Medical College, Wardha, IND
| | - Abhiram Awasthi
- Department of Orthopaedic Surgery, Jawaharlal Nehru Medical College, Wardha, IND
| | - Gajanan Pisulkar
- Department of Orthopaedic Surgery, Jawaharlal Nehru Medical College, Wardha, IND
| | - Shounak Taywade
- Department of Orthopaedic Surgery, Jawaharlal Nehru Medical College, Wardha, IND
| | - Nitin Samal
- Department of Orthopaedic Surgery, Jawaharlal Nehru Medical College, Wardha, IND
| |
Collapse
|
2
|
Daher J, Desai B, Nammour M, Warren M, Chimento G. Long-term Follow-up on Revisions of a Recalled Large Head Metal-on-metal Hip Prosthesis: A Single Surgeon Series. Arthroplast Today 2023; 22:101163. [PMID: 37521732 PMCID: PMC10374868 DOI: 10.1016/j.artd.2023.101163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 03/29/2023] [Accepted: 05/14/2023] [Indexed: 08/01/2023] Open
Abstract
Background In 2010, a recall was issued for a specific monoblock large head metal-on-metal (MoM) hip prosthesis due to short-term revision rates of 12%-13% (articular surface replacement, DePuy Orthopaedics, Inc., Warsaw, IN). High complication, infection, and rerevision rates for revised MoM implants have been reported. The purpose of the study is to report long-term outcomes and trend metal ion levels of this recalled MoM prosthesis from a single surgeon series. Methods Retrospective chart review was performed on all patients that underwent revision of large MoM hip replacements between 2010 and 2015. Pre- and post-revision Harris Hip Score (HHS), cup abduction angles, anteversion angles, and cup sizes were compared. Survivorship and HHS were the primary outcomes measured; serum cobalt and chromium levels were secondary outcomes. Multivariate linear regression was used to examine the correlation between prerevision serum metal ion levels and HHS. Results A total of 24 hips (21 patients) met inclusion criteria. Mean time to revision was 4.12 years ± 1.1. Mean follow-up was 10.0 years (7-11.9 years). Mean HHS increased significantly after revision from 48.5 to 89.5 (P < .001). Higher prerevision cobalt levels were correlated with lower prerevision HHS (cobalt R = 0.25; chromium R = 0.3160). There was no correlation with prerevision cobalt (P = .2671) or chromium (P = .3160) with postrevision HHS. Most recent metal ion testing revealed a significant decrease in both cobalt (P = .0084) and chromium (P = .0115). Survival rate is 100%. Conclusions Our study showed excellent survivorship and outcomes at 10 years. There were no failures for any reason including infection. This differs from previous studies and confirms excellent long-term results are possible with revision of this recalled MoM implant.
Collapse
Affiliation(s)
- Jimmy Daher
- Department of Orthopaedic Surgery, Ochsner Medical Center, New Orleans, LA, USA
| | - Bhumit Desai
- Department of Orthopaedic Surgery, Ochsner Medical Center, New Orleans, LA, USA
- Ochsner Clinical School, University of Queensland School of Medicine, New Orleans, LA, USA
| | - Michael Nammour
- Department of Orthopaedic Surgery, Ochsner Medical Center, New Orleans, LA, USA
| | - Michael Warren
- Department of Orthopaedic Surgery, Ochsner Medical Center, New Orleans, LA, USA
| | - George Chimento
- Department of Orthopaedic Surgery, Ochsner Medical Center, New Orleans, LA, USA
- Ochsner Clinical School, University of Queensland School of Medicine, New Orleans, LA, USA
| |
Collapse
|
3
|
Cannella A, Greco T, Polichetti C, De Martino I, Mascio A, Maccauro G, Perisano C. A Rare Case of Adverse Reaction to Metal Debris in a Ceramic-on-Ceramic Total Hip Replacement. J Funct Biomater 2022; 13:145. [PMID: 36135580 PMCID: PMC9501357 DOI: 10.3390/jfb13030145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 09/02/2022] [Accepted: 09/05/2022] [Indexed: 11/17/2022] Open
Abstract
Adverse Reaction to Metal Debris (ARMD) is one of the most frequent complications after Total Hip Replacement (THR) and often a cause of surgical revision. This is true especially for implants with Metal-on-Metal (MoM) and Large Diameter Heads (LDHs), which are frequently used to improve stability and reduce the risk of dislocation. However, ARMD is not exclusive to MoM replacement, as it can also occur in other implants such Ceramic-on-Ceramic (CoC), Metal-on-Polyethylene (MoP), and Ceramic-on-Polyethylene (CoP). In these non-MoM implants, ARMD is not caused by the tribo-corrosion between bearing surfaces but, rather, by the fretting at the interface between neck and stem of dissimilar metals. A case of a severe ARMD that happened to a 73-year-old female patient with CoC bearing THR at the right hip is presented in this case report. In this case, the ARMD was misdiagnosed for over a year, resulting in the development of a massive pseudotumor. The treatment of choice was a two-stage revision with the implant of a hip megaprosthesis. After more than 2 years of follow-up, complete recovery of hip Range of Motion (ROM) and normalization of chromium and cobalt levels in blood and urine were achieved. Despite the relatively short follow-up period, this can be considered a successful treatment of a major and misdiagnosed ARMD in a non-MoM hip replacement.
Collapse
Affiliation(s)
- Adriano Cannella
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Orthopedics and Trauma Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Tommaso Greco
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Orthopedics and Trauma Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Chiara Polichetti
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Orthopedics and Trauma Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Ivan De Martino
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Antonio Mascio
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Orthopedics and Trauma Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Giulio Maccauro
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Orthopedics and Trauma Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Carlo Perisano
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| |
Collapse
|
4
|
Chen Z, Chen W, Yu W, Zhao M, Lin J, Zhou C, Chen H, Ye J, Zeng X, Zhuang J. Mid-term outcomes of uncemented or cemented arthroplasty revision following metal-on-metal total hip arthroplasty failure: a retrospective observational study. J Int Med Res 2021; 48:300060520932051. [PMID: 32600087 PMCID: PMC7328484 DOI: 10.1177/0300060520932051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Objective To retrospectively compare the mid-term outcomes of uncemented or cemented total hip arthroplasty (THA) revision for prior primary metal-on-metal (MoM) THA failure. Methods Data from 278 patients (278 hips) who underwent uncemented THA (UTHA) or cemented THA (CTHA) for prior primary MoM-THA failure from 2006 to 2016 were retrospectively analysed. Follow-up was performed 6 months, 1 year, 2 years, and then every 2 years after conversion. The mean follow-up time was 96 months (range, 64–128 months). The primary endpoint was the modified Harris hip score (HHS). The secondary endpoint was the major orthopaedic complication rate. Results The HHS showed significantly greater differences in the CTHA than UTHA group 12 months after conversion. From the 12th month after conversion to the final follow-up, CTHA yielded better functional outcomes than UTHA. There were significant differences between the UTHA and CTHA groups in the rates of re-revision (14.4% vs. 4.9%, respectively), aseptic loosening (17.3% vs. 6.8%, respectively), and periprosthetic fracture (11.5% vs. 3.9%, respectively). Conclusion CTHA has more advantages than UTHA in terms of improving functional outcomes and decreasing the major orthopaedic complication rate.
Collapse
Affiliation(s)
- Zhao Chen
- Department of Pediatric Orthopaedics, Fujian Children's Hospital, Fuzhou, Fujian Province, China
| | - Wenli Chen
- Department of Neurosurgery, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Weiguang Yu
- Department of Orthopaedics, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Mingdong Zhao
- Department of Neurosurgery, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Jinluan Lin
- Department of Orthopaedics, Jinshan Hospital, Fudan University, Shanghai, China
| | - Chaoming Zhou
- Department of Orthopaedics, Jinshan Hospital, Fudan University, Shanghai, China
| | - Hui Chen
- Department of Orthopaedics, Jinshan Hospital, Fudan University, Shanghai, China
| | - Junxing Ye
- Department of Orthopaedics, Jinshan Hospital, Fudan University, Shanghai, China
| | - Xianshang Zeng
- Department of Orthopaedics, Jinshan Hospital, Fudan University, Shanghai, China
| | - Jintao Zhuang
- Department of Orthopaedics, Jinshan Hospital, Fudan University, Shanghai, China
| |
Collapse
|
5
|
Affatato S, Castiello E, Amendola L, Comitini S, Prudhon JL, Tigani D. Revision of a Monoblock Metal-on-Metal Cup Using a Dual Mobility Component: Is It a Reasonable Option? MATERIALS (BASEL, SWITZERLAND) 2020; 13:ma13092040. [PMID: 32349434 PMCID: PMC7254332 DOI: 10.3390/ma13092040] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Revised: 04/22/2020] [Accepted: 04/24/2020] [Indexed: 06/11/2023]
Abstract
Revision of large-diameter, monoblock acetabular components for both hip resurfacing arthroplasty and metal-on-metal (MoM) total hip arthroplasty (THA) is correlated to a high amount of complications. For this reason, performing a limited revision by conversion to a dual mobility (DM) without acetabular component exchange has been proposed in order to limit these complications. Although DM bearing offers an easy solution avoiding the intraoperative and time-associated complications, concern about polyethylene wear and stability remains due to the difference regarding the design, the coverage angle and the clearance of the two implants. In order to evaluate the performance of this new solution with the new material to prevent the possibility of failure it is essential to conduct a review of the literature A qualitative systematic review of the literature has been conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A comprehensive search of PubMed, EMBASE, Google Scholar, and Scopus for English and French articles between January 2000 and October 2019 was performed, with the primary objective of finding articles about dual mobility bearing coupling with large metal-on-metal cup in the case of hip revision procedure. Various combinations of the key words were used in the search strategy. Thirteen articles with DM bearing mated with MoM cup were analyzed. Of the 130 hip revisions selected, with a follow-up from 6 to 53 months, there were a total of 14 with complications (10.77%): four true dislocations (3.08%); six intra-prosthetic dislocations (IPD, 4.6%), two of which presented plastic deformation and polyethylene wear; four other complications (3.08%), included a cup osteolysis, a clicking noise, a superficial infection and a periprosthetic fracture. All the mentioned true dislocations occurred during the first month while IPDs appeared during the first two years from the index revision. In conclusion, according to the literature analyzed, we can stress that the concerns and doubts about mating a DM bearing with large MoM cup cannot be dissolved. It has been pointed out that a DM bearing is not designed for a MoM cup; it is not mechanically tested on MoM cups, which presents different clearance and coverage angles. Predictable complications may occur, such as IPD, polyethylene wear and true dislocation. These complications have been reported at an even higher rate than they were in the eighties, when the first generation of DM implants were of a lower quality of polyethylene and the characteristic of the design was less optimal than modern ones.
Collapse
Affiliation(s)
- Saverio Affatato
- Laboratorio di Tecnologia Medica, IRCCS – Istituto Ortopedico Rizzoli, 40100 Bologna, Italy
| | - Emanuela Castiello
- Unità Operativa Complessa di Ortopedia e Traumatologia, Ospedale Maggiore, 40100 Bologna, Italy; (E.C.); (L.A.); (S.C.); (D.T.)
| | - Luca Amendola
- Unità Operativa Complessa di Ortopedia e Traumatologia, Ospedale Maggiore, 40100 Bologna, Italy; (E.C.); (L.A.); (S.C.); (D.T.)
| | - Saverio Comitini
- Unità Operativa Complessa di Ortopedia e Traumatologia, Ospedale Maggiore, 40100 Bologna, Italy; (E.C.); (L.A.); (S.C.); (D.T.)
| | | | - Domenico Tigani
- Unità Operativa Complessa di Ortopedia e Traumatologia, Ospedale Maggiore, 40100 Bologna, Italy; (E.C.); (L.A.); (S.C.); (D.T.)
| |
Collapse
|
6
|
Colacchio ND, Wooten CJ, Martin JR, Masonis JL, Fehring TK. Dual Mobility for Monoblock Metal-on-Metal Revision-Is It Safe? J Arthroplasty 2020; 35:508-512. [PMID: 31662280 DOI: 10.1016/j.arth.2019.09.028] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Revised: 09/12/2019] [Accepted: 09/17/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Revision of monoblock metal-on-metal (MoM) total hip arthroplasty (THA) is associated with high complication rates. Limited revision by conversion to a dual mobility (DM) without acetabular component extraction may mitigate these complications. However, the concern for polyethylene wear and osteolysis remains unsettled. This study investigates the results of DM conversion of monoblock MoM THA compared to formal acetabular revision. METHODS One hundred forty-three revisions of monoblock MoM THA were reviewed. Twenty-nine were revisions to a DM construct, and 114 were complete revisions of the acetabular component. Mean patient age was 61, 54% were women. Components used, acetabular cup position, radiographic outcomes, serum metal ion levels, and HOOS Jr clinical outcome scores were investigated. RESULTS At 3.9 years of follow-up (range 2-5), there were 2 revisions (6.9%) in the DM cohort, 1 for instability and another for periprosthetic fracture. Among the formal acetabular revision group there was a 20% major complication rate (23/114) and 16% underwent revision surgery (18/114) for aseptic loosening of the acetabular component (6%), deep infection (6%), dislocation (4%), acetabular fracture (3%), or delayed wound healing (6%). In the DM cohort, there were no radiographic signs of aseptic loosening, component migration, or polyethylene wear. One DM patient had a small posterior metadiaphyseal femur lesion that will require close monitoring. There were no other radiographic signs of osteolysis. There were no clinically significant elevations of serum metal ion levels. HOOS Jr scores were favorable. CONCLUSION Limited revision with conversion to DM is a viable treatment option for failed monoblock MoM THA with lower complication rates than formal revision. Limited revision to DM appears to be a safe option for revision of monoblock MoM THA with a cup in good position and an internal geometry free of sharp edges or articular surface damage. Longer follow-up is needed to demonstrate any potential wear implications of these articulations.
Collapse
Affiliation(s)
| | - Clint J Wooten
- Department of Orthopaedic Surgery, OrthoCarolina, Charlotte, NC
| | - John R Martin
- Department of Orthopaedic Surgery, OrthoCarolina, Charlotte, NC
| | - John L Masonis
- Department of Orthopaedic Surgery, OrthoCarolina, Charlotte, NC
| | | |
Collapse
|
7
|
Gascoyne T, Flynn B, Turgeon T, Burnell C. Mid-term progressive loosening of hydroxyapatite-coated femoral stems paired with a metal-on-metal bearing. J Orthop Surg Res 2019; 14:225. [PMID: 31324195 PMCID: PMC6642514 DOI: 10.1186/s13018-019-1271-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Accepted: 07/08/2019] [Indexed: 12/27/2022] Open
Abstract
Background Several hydroxyapatite (HA)-coated femoral stems from a single manufacturer were identified to have aseptically loosened at mid-term follow-up despite prior radiographic appearance of osseointegration. Possible causes and associated risk factors for stem loosening were explored through radiographic review and implant retrieval analysis. Methods Forty-six retrieved hip stems (Corail, DePuy-Synthes) were identified and grouped by bearing type: metal-on-metal (MoM), metal-on-polyethylene, and ceramic-on-ceramic. Stem lucency was graded on post-operative radiographs up to the time of revision. Stems were examined for stripping of the HA coating, taper corrosion, and bearing wear in metal-on-metal cases. Patient demographics, implant design features, and perioperative data were collected from electronic databases and patient charts. Results Aseptic loosening occurred in 37% of cases examined. MoM bearings were associated with 7.25 times greater risk of loosening compared to other bearing types. Stem radiolucency was more prevalent for MoM cases and, although not statistically significant, demonstrated progressive lucency. Taper corrosion appeared more severe for MoM cases and correlated with proximal stem radiolucency. Removal of the HA coating from the stems was associated with both taper corrosion and MoM bearing wear. Length of implantation was a confounding factor for the MoM cases. Conclusion This study has demonstrated a high risk of mid-term loosening of previously osseointegrated HA-coated femoral stems when paired with a MoM bearing. The mechanism of loosening appears progressive in nature and related to the MoM bearing, possibly interacting with the HA coating. If such loosening is recognized early, rapid revision may allow for retention of the femoral stem.
Collapse
Affiliation(s)
- Trevor Gascoyne
- Orthopaedic Innovation Centre, 320-1155 Concordia Avenue, Winnipeg, R2K2M9, Manitoba, Canada
| | - Bryan Flynn
- Concordia Joint Replacement Group, 310-1155 Concordia Avenue, Winnipeg, Manitoba, R2K 2M9, Canada
| | - Thomas Turgeon
- Concordia Joint Replacement Group, 310-1155 Concordia Avenue, Winnipeg, Manitoba, R2K 2M9, Canada.,Department of Surgery, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Colin Burnell
- Concordia Joint Replacement Group, 310-1155 Concordia Avenue, Winnipeg, Manitoba, R2K 2M9, Canada. .,Department of Surgery, University of Manitoba, Winnipeg, Manitoba, Canada.
| |
Collapse
|
8
|
Transition from metal-DTH resistance to susceptibility is facilitated by NLRP3 inflammasome signaling induced Th17 reactivity: Implications for orthopedic implants. PLoS One 2019; 14:e0210336. [PMID: 30653583 PMCID: PMC6336398 DOI: 10.1371/journal.pone.0210336] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Accepted: 12/20/2018] [Indexed: 12/13/2022] Open
Abstract
Metal hypersensitivity has been recognized as an adverse biologic reaction that can compromise total joint arthroplasty (TJA) performance. However, the etiology of metal hypersensitivity responses in TJAs remains unclear. Metal implant debris is known to act as a danger signal that drives NLRP3 inflammasome activation. It remains unknown if implant debris induced inflammasome activation regulates T cell lineage in TJA metal hypersensitivity responses. In this study, we show both in vivo and in vitro that the pathogenesis of metal hypersensitivity responses to implant debris are largely dependent on activation of the inflammasome/caspase-1 pathway and subsequent production of IL-17A/F by CD4+ T cells. Inhibiting either the inflammasome pathway or IL-17A bioactivity in vivo and in vitro (in vivo using NLRP3 and Caspase-1 deficient mice or in vitro using blocking agents such as Capase-1 inhibitor, IL-1Ra and anti-IL-17A), significantly (p<0.05) mitigated metal-DTH paw inflammation as well as lymphocyte cytokine (IFN-γ and IL-17) and proliferation responses in metal-sensitized mice and primary human PBMCs. This study provides mechanistic insight into how in vivo exposure to orthopedic implant debris, and metals in general, elicits NLRP3 inflammasome activation that mediates the generation of IL-17A/F producing CD4+ T cells, leading to metal-delayed type hypersensitivity reactions.
Collapse
|
9
|
|
10
|
Letter to the Editor: Five Hundred Fifty-five Retrieved Metal-on-metal Hip Replacements of a Single Design Show a Wide Range of Wear, Surface Features, and Histopathologic Reactions. Clin Orthop Relat Res 2018; 476:2278-2279. [PMID: 30286002 PMCID: PMC6259999 DOI: 10.1097/corr.0000000000000517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
11
|
Martin JR, Jennings JM, Watters TS, Levy DL, Miner TM, Dennis DA. Midterm Prospective Comparative Analysis of 2 Hard-on-Hard Bearing Total Hip Arthroplasty Designs. J Arthroplasty 2018; 33:1820-1825. [PMID: 29429884 DOI: 10.1016/j.arth.2018.01.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2017] [Revised: 01/15/2018] [Accepted: 01/17/2018] [Indexed: 02/01/2023] Open
Abstract
INTRODUCTION Hard-on-hard (HoH) bearing surfaces in total hip arthroplasty (THA) are commonly utilized in younger patients and may decrease mechanical wear compared to polyethylene bearing surfaces. To our knowledge, no study has prospectively compared the 2 most common HoH bearings, ceramic-on-ceramic (CoC) and metal-on-metal (MoM) THA. MATERIALS AND METHODS We prospectively enrolled 40 patients to undergo an MoM THA and 42 patients to undergo a CoC THA utilizing the same acetabular component. Patients were followed up for a minimum of 2 years. Comparative outcomes included clinical scores, revision or reoperation for any reason, complication rates, and radiographic outcomes. RESULTS The average follow-up was significantly longer in the CoC cohort (94 vs 74 months; P = .005). The CoC cohort had significantly improved Harris Hip Scores (95 vs 84; P = .0009) and pain scores (42 vs 34; P = .0003). The revision (0% vs 31%; P = .0001), reoperation (7.5% vs 36%; P = .004), and complication rates (10% vs 56%; P = .0001) were significantly lower in the CoC cohort. There were no statistically significant differences in radiographic parameters. CONCLUSION The clinical outcomes in the CoC cohort exceeded the MoM cohort. It is unlikely that another prospective comparative study of HoH THAs will be conducted. Our midterm results support the use of CoC THA as a viable option that may reduce long-term wear in younger patients. Close surveillance of MoM THA patients is recommended considering the higher failure and complication rates reported in this cohort.
Collapse
Affiliation(s)
| | | | | | | | | | - Douglas A Dennis
- Colorado Joint Replacement, Denver, CO; Department of Biomedical Engineering, University of Tennessee, Knoxville, TN; Bioengineering, University of Denver, Denver, CO; Department of Orthopaedics, University of Colorado School of Medicine, Denver, CO
| |
Collapse
|
12
|
Lehtovirta L, Reito A, Parkkinen J, Peräniemi S, Vepsäläinen J, Eskelinen A. Association between periprosthetic tissue metal content, whole blood and synovial fluid metal ion levels and histopathological findings in patients with failed metal-on-metal hip replacement. PLoS One 2018; 13:e0197614. [PMID: 29768492 PMCID: PMC5955572 DOI: 10.1371/journal.pone.0197614] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Accepted: 05/04/2018] [Indexed: 02/08/2023] Open
Abstract
Adverse Reaction to Metal Debris (ARMD) is a major cause of implant failure leading to revision surgery in patients with metal-on-metal (MoM) hip arthroplasties. However, the pathogenesis and its association to implant wear are poorly understood and previous studies have yielded discrepant results. We sought to investigate the associations between histological findings, whole blood and synovial fluid metal ion concentrations and periprosthetic tissue metal concentrations in patients with MoM total hip replacements and hip resurfacings revised for ARMD. 107 hips in total were included in our study. Of these, 87 were total hip replacements and 20 were hip resurfacings, respectively. We found that whole blood, synovial fluid and periprosthetic tissue metal concentrations correlated poorly with histological findings. We suggest that the lack of a clear association between histological findings and wear measures in the present study as well as in previous studies is mostly influenced by variability in patient susceptibility. However, patients presenting with perivascular lymphocytic infiltration had lower chromium concentration in their periprosthetic tissues than patients with no perivascular lymphocytic infiltration. This may reflect the role of metal hypersensitivity in implant failure in these patients. Patients with total hip replacements evinced more necrosis and lymphocytic infiltration in their tissues than patients with hip resurfacings. This suggests that trunnion wear debris is more cytotoxic and/or immunogenic than bearing wear debris leading to higher failure rates seen in patients with total hip replacements.
Collapse
Affiliation(s)
- Lari Lehtovirta
- University of Tampere, Tampere, Finland
- Coxa Hospital for Joint Replacement, Tampere, Finland
- * E-mail:
| | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | | | | | | |
Collapse
|
13
|
Fretting and Corrosion Damage in Retrieved Metal-on-Polyethylene Modular Total Hip Arthroplasty Systems: What Is the Importance of Femoral Head Size? J Arthroplasty 2018; 33:931-938. [PMID: 29113756 DOI: 10.1016/j.arth.2017.10.010] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2017] [Revised: 09/15/2017] [Accepted: 10/05/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Fretting and corrosion at the modular femoral head-femoral neck (taper) interface have been reported in retrieved total hip arthroplasty (THA) prostheses. This study investigated associations among implant design, radiographic factors, and patient factors with corrosion and fretting at the taper interface in retrieved metal-on-polyethylene modular THA prostheses. METHODS Ninety-two retrieved primary metal-on-polyethylene THA implants were evaluated and graded for fretting, corrosion, and damage at the taper interface, including the femoral stem trunnion and femoral head. Preoperative radiographs were assessed for osteolysis and femoral stem alignment; and medical records were reviewed for demographic data. RESULTS Male patients had greater head corrosion (P = .037), patient age at revision had a weak, negative correlation with trunnion corrosion (ρ = -0.20, P = .04), and both body mass index and duration of implantation had weak, positive correlations with head fretting (ρ = 0.26, P = .01 and ρ = 0.33, P = .001, respectively). A weak, negative correlation was found between femoral head size and both head fretting and head corrosion (ρ = -0.26, P = .007 and ρ = -0.21, P = .028, respectively), and a weak, positive correlation was found between head offset and trunnion fretting (ρ = 0.23, P = .030). Varus femoral stem alignment was associated with greater head fretting (P = .038). CONCLUSION Larger femoral head sizes were correlated with less severe head corrosion and head fretting, with 28-mm heads exhibiting more moderate-to-severe damage. Other factors, such as head-taper engagement and geometry, rather than head size, may affect rates of corrosion and fretting damage at the taper interface.
Collapse
|
14
|
Matharu GS, Hunt LP, Murray DW, Howard P, Pandit HG, Blom AW, Bolland B, Judge A. Is the rate of revision of 36 mm metal-on-metal total hip arthroplasties with Pinnacle acetabular components related to the year of the initial operation? an interrupted time-series analysis using data from the National Joint Registry for England and Wales. Bone Joint J 2018; 100-B:33-41. [PMID: 29305448 DOI: 10.1302/0301-620x.100b1.bjj-2017-0625.r2] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
AIMS The aim of this study was to determine whether the rates of revision for metal-on-metal (MoM) total hip arthroplasties (THAs) with Pinnacle components varied according to the year of the initial operation, and compare these with the rates of revision for other designs of MoM THA. PATIENTS AND METHODS Data from the National Joint Registry for England and Wales included 36 mm MoM THAs with Pinnacle acetabular components which were undertaken between 2003 and 2012 with follow-up for at least five years (n = 10 776) and a control group of other MoM THAs (n = 13 817). The effect of the year of the primary operation on all-cause rates of revision was assessed using Cox regression and interrupted time-series analysis. RESULTS For MoM THAs involving Pinnacle components, those undertaken between 2007 and 2012 had higher rates of revision compared with those undertaken between 2004 and 2006 (hazard ratio (HR) 2.01; 95% confidence interval (CI) 1.57 to 2.57; p < 0.001). For THAs undertaken during and after 2007, the number of revisions per 1000 implant-years at risk significantly increased by 5.20 (95% CI 0.52 to 9.89; p = 0.033) compared with those undertaken before this time. In the control group, THAs undertaken between 2007 and 2012 also had higher rates of revision (HR 1.77; 95% CI 1.49 to 2.10; p < 0.001), with revisions per 1000 implant-years for those undertaken during and after 2007 significantly increasing by 6.13 (95% CI 1.42 to 10.83; p = 0.016). CONCLUSION The five-year revision rates were significantly increased for all primary MoM THAs undertaken from 2007 onwards. Contrary to recent reports, this finding was not specific to those involving Pinnacle acetabular components and may be explained by increased surveillance and recent lowering of the threshold for revision. Cite this article: Bone Joint J 2018;100-B:33-41.
Collapse
Affiliation(s)
- G S Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Road, Oxford OX3 7LD UK, and Research Fellow at the Musculoskeletal Research Unit and Department of Translational Health Sciences, University of Bristol, Bristol BS10 5NB, UK
| | - L P Hunt
- Musculoskeletal Research Unit, Department of Translational Health Sciences, University of Bristol, Bristol BS10 5NB, UK
| | - D W Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD, UK
| | - P Howard
- Royal Derby Hospital, Uttoxeter Road, Derby DE22 3NE, UK
| | - H G Pandit
- Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Chapel Allerton Hospital, Chapeltown Road, Leeds LS7 4SA, UK, and Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Windmill Road, Oxford OX3 7LD, UK
| | - A W Blom
- Department of Translational Health Sciences, Bristol Medical School, University of Bristol, Bristol BS10 5NB, UK
| | - B Bolland
- Musgrove Park Hospital, Taunton, Somerset TA1 5DA, UK
| | - A Judge
- Department of Translational Health Sciences, Bristol Medical School, University of Bristol, Bristol BS10 5NB, UK, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Windmill Road, Oxford OX3 7LD, UK, and MRC Lifecourse Southampton General Hospital, University of Southampton, Tremona Road, Southampton SO16 6YD, UK
| |
Collapse
|
15
|
Steffen JE, Fassler EA, Reardon KJ, Egilman DS. Grave fraudulence in medical device research: a narrative review of the PIN seeding study for the Pinnacle hip system. Account Res 2017; 25:37-66. [DOI: 10.1080/08989621.2017.1405259] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
| | | | | | - David S. Egilman
- Department of Family Medicine, Brown University, Attleboro, Massachusetts, USA
| |
Collapse
|
16
|
Wang J, Wang D, Du J, Lin Z. A new strategy to reconstruct type III acetabular bone defect associated with inflammatory pseudotumor: combined medial and lateral acetabular bone grafting: A case report. Medicine (Baltimore) 2017; 96:e8777. [PMID: 29390269 PMCID: PMC5815681 DOI: 10.1097/md.0000000000008777] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
RATIONALE Inflammatory pseudotumor has been commonly reported in patients undergoing total hip arthroplasty (THA). PATIENT CONCERNS We reported a patient who had a massive intra-pelvic pseudotumour and acetabular bone defect underwent two-stage revision THA. DIAGNOSES A new surgical strategy for pseudotumor after THA is performed. INTERVENTIONS Thorough debridement intra-pelvic pseudotumour via Smith-Petersen approach, bone grafting on iliac medial surface and plate-screw internal fixation were performed in the first stage, followed by revision of the loosened prosthesis to a cementless primary prosthesis in the second stage. OUTCOMES A follow-up for 5 years showed satisfactory recovery of function. LESSONS This surgical revision is less invasive than conventional methods, resulting in a stable and well-functioning hip joint after mid-term follow-up for 5 years.
Collapse
|
17
|
Matharu GS, Nandra RS, Berryman F, Judge A, Pynsent PB, Dunlop DJ. Risk factors for failure of the 36 mm metal-on-metal Pinnacle total hip arthroplasty system: a retrospective single-centre cohort study. Bone Joint J 2017; 99-B:592-600. [PMID: 28455467 PMCID: PMC5413867 DOI: 10.1302/0301-620x.99b5.bjj-2016-1232.r1] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2016] [Accepted: 12/30/2016] [Indexed: 12/12/2022]
Abstract
Aims To determine ten-year failure rates following 36 mm metal-on-metal
(MoM) Pinnacle total hip arthroplasty (THA), and identify predictors
of failure. Patients and Methods We retrospectively assessed a single-centre cohort of 569 primary
36 mm MoM Pinnacle THAs (all Corail stems) followed up since 2012
according to Medicines and Healthcare Products Regulation Agency
recommendations. All-cause failure rates (all-cause revision, and
non-revised cross-sectional imaging failures) were calculated, with predictors
for failure identified using multivariable Cox regression. Results Failure occurred in 97 hips (17.0%). The ten-year cumulative
failure rate was 27.1% (95% confidence interval (CI) 21.6 to 33.7).
Primary implantation from 2006 onwards (hazard ratio (HR) 4.30;
95% CI 1.82 to 10.1; p = 0.001) and bilateral MoM hip arthroplasty
(HR 1.59; 95% CI 1.03 to 2.46; p = 0.037) predicted failure. The
effect of implantation year on failure varied over time. From four
years onwards following surgery, hips implanted since 2006 had significantly
higher failure rates (eight years 28.3%; 95% CI 23.1 to 34.5) compared
with hips implanted before 2006 (eight years 6.3%; 95% CI 2.4 to
15.8) (HR 15.2; 95% CI 2.11 to 110.4; p = 0.007). Conclusion We observed that 36 mm MoM Pinnacle THAs have an unacceptably
high ten-year failure rate, especially if implanted from 2006 onwards
or in bilateral MoM hip patients. Our findings regarding implantation
year and failure support recent concerns about the device manufacturing
process. We recommend all patients undergoing implantation since
2006 and those with bilateral MoM hips undergo regular investigation,
regardless of symptoms. Cite this article: Bone Joint J 2017;99-B:592–600.
Collapse
Affiliation(s)
| | - R S Nandra
- The Royal Orthopaedic Hospital, Birmingham, B31 2AP, UK
| | - F Berryman
- The Royal Orthopaedic Hospital, Birmingham, B31 2AP, UK
| | - A Judge
- University of Oxford, Oxford, OX3 7LD, UK
| | - P B Pynsent
- School of Clinical and Experimental Medicine, University of Birmingham, B15 2TT, UK
| | - D J Dunlop
- The Royal Orthopaedic Hospital, Birmingham, B31 2AP, UK
| |
Collapse
|
18
|
Metal-on-Metal Total Hip Arthroplasty at Five to Twelve Years Follow-Up: A Concise Follow-Up of a Previous Report. J Arthroplasty 2016; 31:1773-8. [PMID: 27113940 DOI: 10.1016/j.arth.2016.01.058] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2015] [Revised: 01/12/2016] [Accepted: 01/28/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Concern has arisen regarding potential complications with modular metal-on-metal (MoM) acetabular components in total hip arthroplasty. The purpose of this study was to analyze longitudinally the longer term results of a previously reported cohort of patients utilizing a cementless modular acetabular component with a MoM bearing. METHODS One hundred sixty-nine consecutive but selected total hip arthroplasties were performed in 148 patients at 2 institutions using a modular acetabular MoM component. One hundred thirty-nine patients (158 hips) were living at minimum 5 years, 1 patient (1 hip) was lost to follow-up and 8 patients (10 hips) were deceased. Patients were evaluated clinically in terms of revision as well as radiographically. Additional testing (metal ion levels, advanced imaging) was performed when concerns for adverse local tissue reaction (ALTR) arose. RESULTS There were 6 (3.8%) additional hips revised since the prior report for a total of 7 hips (4.4%) revised at 5-12 year follow-up. All newly revised hips (3.8%) demonstrated ALTR. There were 7 (4.7%) additional cases of radiographically detected acetabular osteolysis and 7 (4.7%) cases of femoral osteolysis. CONCLUSION Longitudinal evaluation of a modular MoM bearing surface acetabular component demonstrated increased rates of ALTR and osteolysis at longer duration follow-up. Although greater than 95% of hips in this study performed well at 5-12 years, when comparing the results to metal-on-polyethylene bearings using the same acetabular component, the results were inferior. Longitudinal surveillance is warranted with this design and this bearing surface couple as cases of ALTR and osteolysis increased with longer follow-up.
Collapse
|
19
|
Langton DJ, Sidaginamale RP, Avery P, Waller S, Tank G, Lord J, Joyce T, Cooke N, Logishetty R, Nargol AVF. Retrospective cohort study of the performance of the Pinnacle metal on metal (MoM) total hip replacement: a single-centre investigation in combination with the findings of a national retrieval centre. BMJ Open 2016; 6:e007847. [PMID: 27130159 PMCID: PMC4853972 DOI: 10.1136/bmjopen-2015-007847] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
OBJECTIVES To determine risk factors for revision in patients implanted with a commonly used metal on metal (MoM) hip replacement. DESIGN Retrospective cohort study in combination with a prospective national retrieval study (Northern Retrieval Registry (NRR)). SETTING Combined orthopaedic unit in combination with the NRR. PARTICIPANTS All patients implanted with a DePuy Pinnacle MoM hip prostheses by the 2 senior authors were invited to attend for a review which included clinical examination, blood metal ion measurements, radiographs and targeted imaging. Explanted components underwent wear analysis using validated methodology and these results were compared with those obtained from the NRR. RESULTS 489 MoM Pinnacle hips were implanted into 434 patients (243 females and 191 males). Of these, 352 patients attended the MoM recall clinics. 64 patients had died during the study period. For the purposes of survival analysis, non-attendees were assumed to have well-functioning prostheses. The mean follow-up of the cohort as a whole was 89 months. 71 hips were revised. Prosthetic survival for the whole cohort was 83.6% (79.9-87.3) at 9 years. The majority of explanted devices exhibited signs of taper junction failure. Risk factors for revision were bilateral MoM prostheses, smaller Pinnacle liners, and implantation in 2006 and later years. A significant number of devices were found to be manufactured out of their specifications. This was confirmed with analysis of the wider data set from the NRR. CONCLUSIONS This device was found to have an unacceptably high revision rate. Bilateral prostheses, those implanted into female patients and devices implanted in later years were found to be at greater risk. A significant number of explanted components were found to be manufactured with bearing diameters outside of the manufacturer's stated tolerances. Our findings highlight the clinical importance of hitherto unrecognised variations in device production.
Collapse
Affiliation(s)
| | | | - Peter Avery
- Newcastle University, Newcastle upon Tyne, Newcastle, UK
| | - Sue Waller
- North Tees Nuffield Hospital, Stockton, UK
| | | | | | - Thomas Joyce
- Newcastle University, Newcastle upon Tyne, Newcastle, UK
| | - Nick Cooke
- University Hospital of North Tees, Stockton, UK
| | | | | |
Collapse
|
20
|
Salvage of Monoblock Metal-on-Metal Acetabular Components Using a Dual-Mobility Bearing. J Arthroplasty 2016; 31:846-9. [PMID: 26404847 DOI: 10.1016/j.arth.2015.08.016] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2015] [Revised: 08/17/2015] [Accepted: 08/18/2015] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Large-diameter, monoblock acetabular components have been used for both hip resurfacing arthroplasty and metal-on-metal (MoM) total hip arthroplasty (THA). If revision is required, one solution is to retain the shell and use a dual-mobility bearing. METHODS We reviewed the results of 25 revision THAs including 11 hip resurfacing arthroplasty and 14 MoM THAs where a monoblock acetabular component was mated to a dual-mobility bearing. RESULTS At a mean of 29 months, there was one failure, an intraprosthetic dislocation of the dual-mobility bearing. There was a significant decrease in serum metal ion levels postoperatively. CONCLUSION Retention of a well-fixed, monoblock MoM acetabular shell and mating it to a dual-mobility bearing in the setting of revision surgery seems to be a reasonable, low-morbidity option at short-term follow-up in appropriately positioned cups.
Collapse
|
21
|
Reito A, Lainiala O, Elo P, Eskelinen A. Prevalence of Failure due to Adverse Reaction to Metal Debris in Modern, Medium and Large Diameter Metal-on-Metal Hip Replacements--The Effect of Novel Screening Methods: Systematic Review and Metaregression Analysis. PLoS One 2016; 11:e0147872. [PMID: 26930057 PMCID: PMC4773181 DOI: 10.1371/journal.pone.0147872] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Accepted: 11/25/2015] [Indexed: 11/18/2022] Open
Abstract
Metal-on-metal (MoM) hip replacements were used for almost a decade before adverse reactions to metal debris (ARMD) were found to be a true clinical problem. Currently, there is a paucity of evidence regarding the usefulness of systematic screening for ARMD. We implemented a systematic review and meta-analysis to establish the prevalence of revision confirmed ARMD stratified by the use of different screening protocols in patients with MoM hip replacements. Five levels of screening were identified: no screening (level 0), targeted blood metal ion measurement and/or cross-sectional imaging (level 1), metal ion measurement without imaging (level 2), metal ion measurement with targeted imaging (level 3) and comprehensive screening (both metal ions and imaging for all; level 4). 122 studies meeting our eligibility criteria were included in analysis. These studies included 144 study arms: 100 study arms with hip resurfacings, 33 study arms with large-diameter MoM total hip replacements (THR), and 11 study arms with medium-diameter MoM THRs. For hip resurfacing, the lowest prevalence of ARMD was seen with level 0 screening (pooled prevalence 0.13%) and the highest with level 4 screening (pooled prevalace 9.49%). Pooled prevalence of ARMD with level 0 screening was 0.29% and with level 4 screening 21.3% in the large-diameter MoM THR group. In metaregression analysis of hip resurfacings, level 4 screening was superior with regard to prevalence of ARMD when compared with other levels. In the large diameter THR group level 4 screening was superior to screening 0,2 and 3. These outcomes were irrespective of follow-up time or study publication year. With hip resurfacings, routine cross-sectional imaging regardless of clinical findings is advisable. It is clear, however, that targeted metal ion measurement and/or imaging is not sufficient in the screening for ARMD in any implant concepts. However, economic aspects should be weighed when choosing the preferred screening level.
Collapse
Affiliation(s)
- Aleksi Reito
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33900 Tampere, Finland
- * E-mail:
| | - Olli Lainiala
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33900 Tampere, Finland
| | - Petra Elo
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33900 Tampere, Finland
| | - Antti Eskelinen
- Coxa Hospital for Joint Replacement, Biokatu 6b, 33900 Tampere, Finland
| |
Collapse
|
22
|
Ricciardi BF, Nocon AA, Jerabek SA, Wilner G, Kaplowitz E, Goldring SR, Purdue PE, Perino G. Histopathological characterization of corrosion product associated adverse local tissue reaction in hip implants: a study of 285 cases. BMC Clin Pathol 2016; 16:3. [PMID: 26924942 PMCID: PMC4769839 DOI: 10.1186/s12907-016-0025-9] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2015] [Accepted: 02/22/2016] [Indexed: 12/12/2022] Open
Abstract
Background Adverse local tissue reaction (ALTR), characterized by a heterogeneous cellular inflammatory infiltrate and the presence of corrosion products in the periprosthetic soft tissues, has been recognized as a mechanism of failure in total hip replacement (THA). Different histological subtypes may have unique needs for longitudinal clinical follow-up and complication rates after revision arthroplasty. The purpose of this study was to describe the histological patterns observed in the periprosthetic tissue of failed THA in three different implant classes due to ALTR and their association with clinical features of implant failure. Methods Consecutive patients presenting with ALTR from three major hip implant classes (N = 285 cases) were identified from our prospective Osteolysis Tissue Database and Repository. Clinical characteristics including age, sex, BMI, length of implantation, and serum metal ion levels were recorded. Retrieved synovial tissue morphology was graded using light microscopy. Clinical characteristics and features of synovial tissue analysis were compared between the three implant classes. Histological patterns of ALTR identified from our observations and the literature were used to classify each case. The association between implant class and histological patterns was compared. Results Our histological analysis demonstrates that ALTR encompasses three main histological patterns: 1) macrophage predominant, 2) mixed lymphocytic and macrophagic with or without features of associated with hypersensitivity/allergy or response to particle toxicity (eosinophils/mast cells and/or lymphocytic germinal centers), and 3) predominant sarcoid-like granulomas. Implant classification was associated with histological pattern of failure, and the macrophagic predominant pattern was more common in implants with metal-on-metal bearing surfaces (MoM HRA and MoM LHTHA groups). Duration of implantation and composition of periprosthetic cellular infiltrates was significantly different amongst the three implant types examined suggesting that histopathological features of ALTR may explain the variability of clinical implant performance in these cases. Conclusions ALTR encompasses a diverse range of histological patterns, which are reflective of both the implant configuration independent of manufacturer and clinical features such as duration of implantation. The macrophagic predominant pattern and its mechanism of implant failure represent an important subgroup of ALTR which could become more prominent with increased length of implantation.
Collapse
Affiliation(s)
- Benjamin F Ricciardi
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY USA
| | - Allina A Nocon
- Healthcare Research Institute, Hospital for Special Surgery, New York, NY USA
| | - Seth A Jerabek
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY USA
| | - Gabrielle Wilner
- Division of Research, Hospital for Special Surgery, New York, NY USA
| | - Elianna Kaplowitz
- Division of Research, Hospital for Special Surgery, New York, NY USA
| | - Steven R Goldring
- Division of Research, Hospital for Special Surgery, New York, NY USA
| | - P Edward Purdue
- Division of Research, Hospital for Special Surgery, New York, NY USA
| | - Giorgio Perino
- Department of Pathology and Laboratory Medicine, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA
| |
Collapse
|
23
|
Burge AJ, Gold SL, Lurie B, Nawabi DH, Fields KG, Koff MF, Westrich G, Potter HG. MR Imaging of Adverse Local Tissue Reactions around Rejuvenate Modular Dual-Taper Stems. Radiology 2015; 277:142-50. [DOI: 10.1148/radiol.2015141967] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
24
|
Singh G, Nuechtern JV, Meyer H, Fiedler GM, Awiszus F, Junk-Jantsch S, Bruegel M, Pflueger G, Lohmann CH. Particle characterisation and cytokine expression in failed small-diameter metal-on-metal total hip arthroplasties. Bone Joint J 2015; 97-B:917-23. [DOI: 10.1302/0301-620x.97b7.35163] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The peri-prosthetic tissue response to wear debris is complex and influenced by various factors including the size, area and number of particles. We hypothesised that the ‘biologically active area’ of all metal wear particles may predict the type of peri-prosthetic tissue response. Peri-prosthetic tissue was sampled from 21 patients undergoing revision of a small diameter metal-on-metal (MoM) total hip arthroplasty (THA) for aseptic loosening. An enzymatic protocol was used for tissue digestion and scanning electron microscope was used to characterise particles. Equivalent circle diameters and particle areas were calculated. Histomorphometric analyses were performed on all tissue specimens. Aspirates of synovial fluid were collected for analysis of the cytokine profile analysis, and compared with a control group of patients undergoing primary THA (n = 11) and revision of a failed ceramic-on-polyethylene arthroplasty (n = 6). The overall distribution of the size and area of the particles in both lymphocyte and non-lymphocyte-dominated responses were similar; however, the subgroup with lymphocyte-dominated peri-prosthetic tissue responses had a significantly larger total number of particles. 14 cytokines (interleukin (IL)-1ß, IL-2, IL-4, IL-5, IL-6, IL-10, IL-13, IL-17, interferon (IFN)-γ, and IFN-gamma-inducible protein 10), chemokines (macrophage inflammatory protein (MIP)-1α and MIP-1ß), and growth factors (granulocyte macrophage colony stimulating factor (GM-CSF) and platelet derived growth factor) were detected at significantly higher levels in patients with metal wear debris compared with the control group. Significantly higher levels for IL-1ß, IL-5, IL-10 and GM-CSF were found in the subgroup of tissues from failed MoM THAs with a lymphocyte-dominated peri-prosthetic response compared with those without this response. These results suggest that the ‘biologically active area’ predicts the type of peri-prosthetic tissue response. The cytokines IL-1ß, IL-5, IL-10, and GM-CSF are associated with lymphocyte-dominated tissue responses from failed small-diameter MoM THA. Cite this article: Bone Joint J 2015;97-B:917–23.
Collapse
Affiliation(s)
- G. Singh
- National University Health System, 1E
Kent Ridge Road, 119228, Singapore
| | - J. V. Nuechtern
- University of Hamburg-Eppendorf, Martinistrasse
52, D-20246 Hamburg, Germany
| | - H. Meyer
- Otto-von-Guericke University, Leipziger
Strasse 44, D-39120 Magdeburg, Germany
| | - G. M. Fiedler
- Bern University Hospital, F603, CH-3010
Bern, Switzerland
| | - F. Awiszus
- Otto-von-Guericke University, Leipziger
Strasse 44, D-39120 Magdeburg, Germany
| | - S. Junk-Jantsch
- Evangelisches Krankenhaus, Hans-Sachs-Gasse
10-12, A-1180 Vienna, Austria
| | - M. Bruegel
- Ludwig-Maximilians-University, Marchioninistrasse
15, 81377 Munich, Germany
| | - G. Pflueger
- Evangelisches Krankenhaus, Hans-Sachs-Gasse
10-12, A-1180 Vienna, Austria
| | - C. H. Lohmann
- Otto-von-Guericke University, Leipziger
Strasse 44, D-39120 Magdeburg, Germany
| |
Collapse
|
25
|
Lombardi AV, Berend KR, Morris MJ, Adams JB, Sneller MA. Large-diameter metal-on-metal total hip arthroplasty: dislocation infrequent but survivorship poor. Clin Orthop Relat Res 2015; 473:509-20. [PMID: 25367107 PMCID: PMC4294925 DOI: 10.1007/s11999-014-3976-0] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2014] [Accepted: 09/22/2014] [Indexed: 01/31/2023]
Abstract
BACKGROUND Use of large-diameter metal-on-metal (MoM) articulations in THA increased, at least in part, because of the possibility of achieving improved joint stability and excellent wear characteristics in vitro. However, there have been subsequent concerning reports with adverse reactions to metal debris (ARMD), pseudotumors, and systemic complications related to metal ions. QUESTIONS/PURPOSES The purpose of this study was to determine at a minimum of 2 years' followup (1) the proportion of patients who experienced a dislocation; (2) the short-term survivorship obtained with these implants; (3) the causes of failure and the proportion of patients who developed ARMD; and (4) whether there were any identifiable risk factors for revision. METHODS We reviewed the results of 1235 patients who underwent 1440 large-diameter MoM primary THAs at our institution using two acetabular devices from a single manufacturer with minimum 2-year followup. Large-diameter MoM devices were used in 48% (1695 of 3567) of primary THAs during the study period. We generally used these implants in younger, more active, higher-demand patients, in patients considered at higher risk of instability, and in patients with adequate bone stock to achieve stable fixation without use of screws. Clinical records and radiographs were reviewed to determine the incidence and etiology of revision. Patients whose hips were revised were compared with those not revised to identify risk factors; Kaplan-Meier survivorship analysis was performed as was multivariate analysis to account for potential confounding variables when evaluating risk factors. Minimum followup was 2 years (average, 7 years; range, 2-12 years); complete followup was available in 85% of hips (1440 of 1695). RESULTS Dislocation occurred in one hip overall (<1%; one of 1440). Kaplan-Meier analysis revealed survival free of component revision was 87% at 12 years (95% confidence interval, 84%-90%). The two most common indications for revision were ARMD (48%; 47 of 108 hips revised) and loosening or failure of ingrowth (31%; 34 of 108). Risk factors for component revision were younger age at surgery (relative risk [RR] 0.98 per each increased year; p=0.02), higher cup angle of inclination (RR 1.03 per each increased degree; p=0.04), and female sex (RR 1.67; p=0.03). CONCLUSIONS Large-diameter MoM THAs are associated with a very low dislocation rate, but failure secondary to ARMD and loosening or lack of ingrowth occur frequently. Patients with MoM THA should be encouraged to return for clinical and radiographic followup, and clinicians should maintain a low threshold to perform a systematic evaluation. Early diagnosis and appropriate treatment are recommended to prevent the damaging effects of advanced ARMD. LEVEL OF EVIDENCE Level IV, Therapeutic study.
Collapse
Affiliation(s)
- Adolph V. Lombardi
- Joint Implant Surgeons, Inc, 7277 Smith’s Mill Road, Suite 200, New Albany, OH 43054 USA ,The Ohio State University Wexner Medical Center, Columbus, OH USA ,Mount Carmel Health System, New Albany, OH USA
| | - Keith R. Berend
- Joint Implant Surgeons, Inc, 7277 Smith’s Mill Road, Suite 200, New Albany, OH 43054 USA ,The Ohio State University Wexner Medical Center, Columbus, OH USA ,Mount Carmel Health System, New Albany, OH USA
| | - Michael J. Morris
- Joint Implant Surgeons, Inc, 7277 Smith’s Mill Road, Suite 200, New Albany, OH 43054 USA ,Mount Carmel Health System, New Albany, OH USA
| | - Joanne B. Adams
- Joint Implant Surgeons, Inc, 7277 Smith’s Mill Road, Suite 200, New Albany, OH 43054 USA
| | - Michael A. Sneller
- Joint Implant Surgeons, Inc, 7277 Smith’s Mill Road, Suite 200, New Albany, OH 43054 USA
| |
Collapse
|
26
|
Abstract
BACKGROUND A relatively high percentage of monoblock metal-on-metal total hip arthroplasties (THAs) undergo early revision. Revision of these THAs poses challenges unique to this implant type. The early complications after these revisions remain unreported as do the clinical and demographic factors associated with these complications. QUESTIONS/PURPOSES We describe (1) the frequency of early complications after revision of monoblock metal-on-metal THA; and (2) the clinical and demographic factors associated with complications. METHODS A review of our institution's total joint registry identified 107 patients who underwent 114 revisions of monoblock metal-on-metal THAs. Mean patient age at revision was 60 years (range, 17-84 years), and 65% of the patients were women. Mean followup after revision was 14 months (range, 0-122 months). Revision diagnoses included metallosis (51%), aseptic loosening (27%), infection (7%), pain (6%), malposition (4%), instability (3%), iliopsoas impingement (2%), and periprosthetic fracture (1%). Major complications (instability, infection, aseptic loosening, and wound complications) were documented and included in the analysis. Minor postoperative complications such as urinary tract infection were excluded. RESULTS Twenty-three of 114 procedures (20%) involved at least one early complication after revision of monoblock metal-on-metal THA with 18 (16%) undergoing at least one additional subsequent surgery. The most common complications included aseptic loosening (6%), deep infection (6%), dislocation (4%), and acetabular fracture (3%). Patients who sustained a complication after revision surgery were older on average than those who did not (66 years versus 58 years, p=0.003). There were no differences in complication rate with respect to sex, time to revision, or revision diagnosis. CONCLUSIONS Complications and reoperations occur frequently after revision for failed monoblock metal-on-metal THA (20% and 16%, respectively), and older patients appear to be at greater risk for complications after these revisions. Aseptic loosening, deep infection, and instability are all of great concern after revision and surgeons should be aware of these potential complications when undertaking revision of these THAs. LEVEL OF EVIDENCE Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
27
|
Lainiala O, Eskelinen A, Elo P, Puolakka T, Korhonen J, Moilanen T. Adverse reaction to metal debris is more common in patients following MoM total hip replacement with a 36 mm femoral head than previously thought. Bone Joint J 2014; 96-B:1610-7. [DOI: 10.1302/0301-620x.96b12.33742] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
We conducted a retrospective study to assess the prevalence of adverse reactions to metal debris (ARMD) in patients operated on at our institution with metal-on-metal (MoM) total hip replacements with 36 mm heads using a Pinnacle acetabular shell. A total of 326 patients (150 males, 175 hips; 176 females, 203 hips) with a mean age of 62.7 years (28 to 85) and mean follow-up of 7.5 years (0.1 to 10.8) participating in our in-depth modern MoM follow-up programme were included in the study, which involved recording whole blood cobalt and chromium ion measurements, Oxford hip scores (OHS) and plain radiographs of the hip and targeted cross-sectional imaging. Elevated blood metal ion levels (> 5 parts per billion) were seen in 32 (16.1%) of the 199 patients who underwent unilateral replacement. At 23 months after the start of our modern MoM follow-up programme, 29 new cases of ARMD had been revealed. Hence, the nine-year survival of this cohort declined from 96% (95% CI 95 to 98) with the old surveillance routine to 86% (95% CI 82 to 90) following the new protocol. Although ARMD may not be as common in 36 mm MoM THRs as in those with larger heads, these results support the Medicines and Healthcare Products Regulatory Agency guidelines on regular reviews and further investigations, and emphasise the need for specific a follow-up programme for patients with MoM THRs. Cite this article: Bone Joint J 2014; 96-B:1610–17.
Collapse
Affiliation(s)
- O. Lainiala
- Coxa Hospital for Joint Replacement, Biokatu
6, 33520 Tampere, Finland
| | - A. Eskelinen
- Coxa Hospital for Joint Replacement, Biokatu
6, 33520 Tampere, Finland
| | - P. Elo
- Coxa Hospital for Joint Replacement, Biokatu
6, 33520 Tampere, Finland
| | - T. Puolakka
- Coxa Hospital for Joint Replacement, Biokatu
6, 33520 Tampere, Finland
| | - J. Korhonen
- Coxa Hospital for Joint Replacement, Biokatu
6, 33520 Tampere, Finland
| | - T. Moilanen
- Coxa Hospital for Joint Replacement, Biokatu
6, 33520 Tampere, Finland
| |
Collapse
|
28
|
Wyles CC, Van Demark RE, Sierra RJ, Trousdale RT. High rate of infection after aseptic revision of failed metal-on-metal total hip arthroplasty. Clin Orthop Relat Res 2014; 472:509-16. [PMID: 23846604 PMCID: PMC3890189 DOI: 10.1007/s11999-013-3157-6] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Evidence suggests some metal-on-metal (MOM) THAs have higher rates of failure and subsequent revision than other bearing surfaces. However, there are few studies demonstrating how these patients fare after revision. QUESTIONS/PURPOSES We asked: (1) What is the short-term survivorship of revision THA in patients whose index THAs employed MOM bearings? (2) What are the causes of failure of revision THA in these patients (ie, what are the indications for repeat revision)? (3) What are the most common complications after revisions of MOM THAs? METHODS We identified 37 patients (24 women, 13 men; mean age, 55 years; 37 hips) revised for aseptic failure of primary stemmed MOM THAs. Reasons for revision included pain with loose components (n = 19), adverse reaction to metal debris (n = 8), periprosthetic fracture (n = 4), impingement (n = 3), dislocation (n = 2), and pain of unknown origin (n = 1). Minimum followup was 24 months (mean, 33 months; range, 24-81 months) postrevision, but 11 were not seen in the last 2 years as our routine followup is at 2 and 5 years. Clinical histories were reviewed for reasons for failure of the MOM THAs and complications associated with revision surgery. RESULTS Survivorship free from further revision for any cause was 95% at 24 months and 92% at latest followup (24-81 months). There were three repeat revisions, all for periprosthetic infection, and all were treated with two-stage reimplantation. No other complications were observed. CONCLUSIONS We observed a higher-than-expected rate of infection after revision of MOM THAs. The infection rate was higher in this report than in an earlier series looking at revision THAs for other indications at our institution. As revision of MOM THA becomes more common, it will be important to continue monitoring postrevision outcomes and providing treatment strategies to mitigate complications for these patients.
Collapse
Affiliation(s)
- Cody C. Wyles
- Department of Orthopadic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN 55905 USA
| | - Robert E. Van Demark
- Department of Orthopadic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN 55905 USA
| | - Rafael J. Sierra
- Department of Orthopadic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN 55905 USA
| | - Robert T. Trousdale
- Department of Orthopadic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN 55905 USA
| |
Collapse
|
29
|
Munir S, Cross MB, Esposito C, Sokolova A, Walter WL. Corrosion in modular total hip replacements: An analysis of the head–neck and stem–sleeve taper connections. ACTA ACUST UNITED AC 2013. [DOI: 10.1053/j.sart.2014.01.009] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
30
|
Lohmann CH, Meyer H, Nuechtern JV, Singh G, Junk-Jantsch S, Schmotzer H, Morlock MM, Pflüger G. Periprosthetic tissue metal content but not serum metal content predicts the type of tissue response in failed small-diameter metal-on-metal total hip arthroplasties. J Bone Joint Surg Am 2013; 95:1561-8. [PMID: 24005196 DOI: 10.2106/jbjs.l.01273] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Tissue responses to periprosthetic metal wear debris are complex and poorly understood. There are two predominant tissue responses: a nonspecific macrophage-mediated granulomatous response and lymphocyte-dominated response, which has immunological memory and is mediated by T cells. Delayed hypersensitivity-type responses may accelerate aseptic loosening of arthroplasty implants. We hypothesized that the metal content of periprosthetic tissue but not of serum would be predictive of the type of tissue response to metal wear debris. METHODS We examined twenty-eight total hip arthroplasty implant retrievals from twenty-seven patients who had undergone revision arthroplasty at one institution. Indications for revision were pain and/or osteolysis; one patient had recurrent dislocations. Tissue samples were analyzed microscopically and the metal (Co, Cr, and Ni) content was determined. Explanted prosthetic components were examined for linear wear. Intraoperatively, periprosthetic metallosis was observed in twelve cases and formation of a bursa (pseudotumor) was observed in thirteen. The acetabular cup was loose in eleven cases, the femoral stem was loose in five, and both components were loose in five. RESULTS The metal (Co, Cr, and Ni) content of the periprosthetic tissue ranged from 1.4 to 4604.0 μg/g. Histologically, macrophages containing metal particles as well as diffuse and perivascular lymphocytic infiltration were observed. Fibrin exudation was also visible. Tissues that displayed a predominantly lymphocytic response had a mean metal content of 222.2 ± 52.9 μg/g, whereas those that displayed a macrophage-dominated response had a metal content of 3.0 ± 0.9 μg/g; this difference was significant (p = 0.001). The mean serum metal content did not differ significantly between the two subgroups (60.7 ± 13.4 compared with 43.7 ± 3.8 μg/L, p = 0.105). CONCLUSIONS An association between periprosthetic tissue metal content and hypersensitivity appears likely but needs to be validated with larger-scale retrieval studies. CLINICAL RELEVANCE This study contributes to the understanding of tissue responses to metal wear debris after joint replacement and the factors that are predictive of a type-IV lymphocyte-dominated hypersensitivity reaction.
Collapse
Affiliation(s)
- C H Lohmann
- Department of Orthopaedic Surgery, Otto-Von-Guericke University, Leipziger Strasse 44, D-39120 Magdeburg, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
31
|
Klingenstein GG, Yeager AM, Lipman JD, Westrich GH. Computerized range of motion analysis following dual mobility total hip arthroplasty, traditional total hip arthroplasty, and hip resurfacing. J Arthroplasty 2013; 28:1173-6. [PMID: 23477855 DOI: 10.1016/j.arth.2012.08.017] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 06/28/2012] [Accepted: 08/13/2012] [Indexed: 02/01/2023] Open
Abstract
Newer arthroplasty designs claim to provide superior range of motion (ROM) and greater stability than their predecessors. However, there is no way to compare ROM of implant systems in an equivalent anatomical environment in a clinical setting. This study used computer-aided design to compare ROM after hip resurfacing, 28 mm THA, 36 mm THA, and anatomic dual mobility (ADM) THA in 3D models of 5 cadaver pelvises. ROM to impingement was then tested in 10 different motions and a one-way ANOVA was used to compare results. The hip resurfacing resulted in restricted ROM compared to the other 3 models in all motions except adduction. The ADM, 36 mm, and 28 mm THA resulted in similar ROM. Dual mobility constructs provide comparable ROM in patients where large head THA is not appropriate.
Collapse
|
32
|
Singh G, Meyer H, Ruetschi M, Chamaon K, Feuerstein B, Lohmann CH. Large-diameter metal-on-metal total hip arthroplasties: a page in orthopedic history? J Biomed Mater Res A 2013; 101:3320-6. [PMID: 23529961 DOI: 10.1002/jbm.a.34619] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2012] [Revised: 01/22/2013] [Accepted: 01/23/2013] [Indexed: 01/31/2023]
Abstract
Large-diameter metal-on-metal (MoM) bearings evolved from the success of hip resurfacing. These implants were used in revision surgery in cases with well-fixed acetabular cups but loose or failed femoral stems, to avoid cup revision. Early data showed low rates of dislocation and potentially low wear profiles due to better fluid film lubrication. The risk of impingement was also thought to be low due to the increased head-neck ratio. Subsequently large-diameter MoM heads gained popularity in primary hip replacement. Recent data has emerged on the unacceptably high revision rates among patients with large-diameter MoM total hip arthroplasties (THAs), high blood levels of metal ions, and adverse tissue reactions. The head-neck (cone-taper) modular interface probably represents the weak link in large metal heads that have been used on conventional tapers. Increased torque of the large head, micromotion, and instability at the cone-taper interface, synergistic interactions between corrosion and wear, edge loading, low clearance, and psoas impingement are the likely causes for early failure of these prostheses.
Collapse
Affiliation(s)
- Gurpal Singh
- Department of Orthopedic Surgery, Otto-Von-Guericke University, Leipziger Str. 44, D-39120, Magdeburg, Germany; University Orthopedics, Hand and Reconstructive Microsurgery Cluster, National University Health System, Singapore
| | | | | | | | | | | |
Collapse
|
33
|
Increased range of motion to impingement with large head total hip arthroplasty: point of diminishing returns. Hip Int 2012; 22:261-5. [PMID: 22773504 DOI: 10.5301/hip.2012.9285] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 04/23/2012] [Indexed: 02/04/2023]
Abstract
Large head total hip arthroplasty (THA) is known to increase range of motion to impingement and decrease risk of dislocation, however, this is dependent on accurate component positioning and patient anatomy. In this study, a computer-aided design model was used to determine the effects of component positioning on range of motion to impingement with increasing head size. Three-dimensional models were made of 7 cadaver CT scans and virtual THA was performed with a conventional implant system. Theoretical range of motion to impingement was tested before and after the components were implanted in flexion, extension, internal/external rotation, abduction, adduction, and flexed internal/external rotation. Range of motion increased non-linearly in every motion except for external rotation and adduction with increasing head size, with gains in ROM limited by osseous impingement. Use of large head THA leads to increased ROM to impingement, but with larger head sizes, benefits are limited by bony anatomy.
Collapse
|