1
|
Kurtz MA, Hallab NJ, Rainey JP, Pelt CE, Mihalko WM, Piuzzi NS, Mont MA, Spece H, Kurtz SM. Metal Release in Total Knee Arthroplasty: A Review of Mechanisms, Adverse Local Tissue Reactions, and Biological Effects. J Arthroplasty 2025:S0883-5403(25)00237-2. [PMID: 40090503 DOI: 10.1016/j.arth.2025.03.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2024] [Revised: 03/06/2025] [Accepted: 03/07/2025] [Indexed: 03/18/2025] Open
Abstract
Compared to the hip, where investigators associate metal release with adverse local tissue reactions (ALTRs), metal-related complications in total knee arthroplasty (TKA) remain controversial and underexplored. Primary TKA systems use monobloc components, limiting corrosion and subsequent concerns. However, like the joints they replace, metal components degrade in vivo. In this narrative review, we aimed to summarize clinically relevant knowledge on metal release within the context of TKA for practicing orthopaedic surgeons. We asked: do ALTRs associated with metal release occur in the knee, and if so, to what extent? To answer this research question, we identified in vivo degradation mechanisms, including wear, mechanically assisted crevice corrosion, and electrocautery damage. Next, we synthesized case reports and retrospective clinical studies documenting ALTRs in primary and revision TKAs. Then, we reviewed the biological response to cobalt chrome debris, focusing on genotoxicity, immune responses, and hypersensitivity. While clinical evidence suggests that patients rarely experience severe biological reactions like pseudotumors, ALTRs associated with metal release can and do occur following TKA. To overcome knowledge gaps related to the prevalence of ALTR in TKA, prospective clinical trials are needed.
Collapse
Affiliation(s)
- Michael A Kurtz
- Drexel University Implant Research Core, Philadelphia, Pennsylvania
| | - Nadim J Hallab
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Joshua P Rainey
- Department of Orthopaedic Surgery, University of Utah, Salt Lake City, Utah
| | - Cristopher E Pelt
- Department of Orthopaedic Surgery, University of Utah, Salt Lake City, Utah
| | - William M Mihalko
- University of Tennessee Health Science Center, Campbell Clinic Orthopaedics, Memphis, Tennessee
| | - Nicolas S Piuzzi
- Department of Orthopedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio
| | - Michael A Mont
- The Rubin Institute, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - Hannah Spece
- Drexel University Implant Research Core, Philadelphia, Pennsylvania
| | - Steven M Kurtz
- Drexel University Implant Research Core, Philadelphia, Pennsylvania
| |
Collapse
|
2
|
Nepple CM, Blackburn AZ, Feder OI, Prasad AK, Bedair HS. Minimum 10-Y Follow-Up of Vitamin-E-Diffused Highly Crosslinked Polyethylene Liners in Total Hip Arthroplasty: A Comparative Evaluation From a Prospective, International, Multicenter Cohort Study. J Arthroplasty 2025; 40:718-724. [PMID: 39303910 DOI: 10.1016/j.arth.2024.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 09/02/2024] [Accepted: 09/10/2024] [Indexed: 09/22/2024] Open
Abstract
BACKGROUND Total hip arthroplasty (THA) is a proven and effective treatment for end-stage osteoarthritis. The success of THA is due in part to highly crosslinked polyethylene (XL) implants. In 2007, a new generation of polyethylene liners entered clinical use. The new liners infused polyethylene with vitamin E and became vitamin E infused polyethylene (EP). The EP liner was hypothesized to prevent the loss of mechanical properties caused by oxidation, extending the lifetime of the implant. This international prospective study aimed to quantify the clinical outcomes of a 977 patient cohort receiving EP and XL liners 10 years after surgery. METHODS The prospective cohort study began in 2007, including eight countries and 17 centers. The final cohort included 977 patients (EP liner: n = 520; XL liner: n = 457). Patients were followed preoperatively, postoperatively, and at 1, 3, 5, 7, and 10 years. Each follow-up visit involved clinical evaluation, radiography, and survey collection. The demographics and revisions were also recorded. Mann-Whitney U tests were used to evaluate statistical differences. RESULTS At 10 years following surgery, 534 patients were eligible for follow-up. Of those eligible, 352 patients returned for clinical evaluation (65.9% eligible; 36.0% overall). No statistical differences were found (P > 0.05) in the demographics of the followed-up cohort. The linear wear rates were 0.00338 mm/year for EP liners and 0.0236 mm/year for XL liners using individual regression (P < 0.0001). No significant difference was observed in wear rates using cohort regression. Similarly, surveys suggested no significant outcomes between the EP and XL liner cohorts. The overall incidence of revision was 2.3% for EP and 2.0% for XL liners. CONCLUSIONS The EP liner demonstrated significantly lower wear than its XL counterparts at 10 years after implantation. Results are promising, as vitamin E polyethylene may improve the lifetime performance of THA implants and ensure that arthroplasty innovations reflect the changing patient population.
Collapse
Affiliation(s)
- Cecilia M Nepple
- Harris Orthopaedics Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Amy Z Blackburn
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts
| | - Oren I Feder
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts
| | - Anoop K Prasad
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts
| | - Hany S Bedair
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedic Surgery, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
3
|
Clyburn TA, Abe EA, Jordaan K, Sheehan EC, Radoičić D, Hu Y, Courtney PM, Parvizi J, Goh GS. Does the Use of Ceramic Femoral Head Versus Metal Femoral Head Improve the Outcome of Primary Total Hip Arthroplasty? J Arthroplasty 2025; 40:S118-S120. [PMID: 39447931 DOI: 10.1016/j.arth.2024.10.071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2024] [Revised: 10/10/2024] [Accepted: 10/14/2024] [Indexed: 10/26/2024] Open
Affiliation(s)
- Terry A Clyburn
- Houston Methodist Hospital, Houston Methodist Orthopedics & Sports Medicine, Houston, Texas
| | - Elizabeth A Abe
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Koos Jordaan
- Head Clinical Unit: Arthroplasty, Faculty of Medicine and Health Sciences, Division of Orthopaedic Surgery, Department of Surgical Sciences, Stellenbosch University, Cape Town, South Africa
| | - Eoin C Sheehan
- Department of Orthopaedics, Midland Regional Hospital Tullamore, Tullamore, Ireland
| | - Dragan Radoičić
- Orthopedic Surgery and Traumatology Clinic, Military Medical Academy, Belgrade, Serbia
| | - Yihe Hu
- Department of Orthopedic Surgery, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Paul M Courtney
- Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Javad Parvizi
- International Joint Center, Acıbadem Maslak Hospital, Istanbul, Turkey
| | - Graham S Goh
- Department of Orthopaedic Surgery, Boston University Medical Center, Boston, MA, USA
| |
Collapse
|
4
|
Beckers G, Morcos MW, Lavigne M, Massé V, Kiss MO, Vendittoli PA. Excellent Results of Large-Diameter Ceramic-On-Ceramic Bearings in Total Hip Arthroplasty at Minimum Ten-Year Follow-Up. J Arthroplasty 2024; 39:3028-3035. [PMID: 38909852 DOI: 10.1016/j.arth.2024.06.045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 06/17/2024] [Accepted: 06/18/2024] [Indexed: 06/25/2024] Open
Abstract
BACKGROUND This study reports the minimum 10 years results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head ceramic-on-ceramic bearing. METHODS Of the 276 THAs included in this study, there were eleven deaths and 27 patients lost to follow up (11%) during the follow-up, leaving 237 (85%) hips available for review at a mean of 10.5 years (range, 10 to 12) postoperatively. Reoperations, implant revisions, adverse events, clinical outcomes, radiographic evaluation, and whole blood metal ion levels were assessed at the last follow-up. RESULTS After a minimum of 10 years, implant survivorship was 98.7%. There were 3 revisions (1.3%): one for insufficient acetabular cup primary fixation, one traumatic periprosthetic acetabular fracture, and one probable deep chronic infection. No dislocation or ceramic implant fracture was observed. The mean University of California at Los Angeles activity score, Western Ontario and McMaster Universities Osteoarthritis Index score, and Forgotten Joint Score were 5.6 (2 to 10), 90.1 (9 to 100), and 79.2 (4 to 100), respectively. All patients (100%) were satisfied or very satisfied. Since implantation, 43% of patients reported hearing a squeaking noise from the prosthesis. But all patients who reported squeaking were satisfied with the surgery. The mean titanium level was 2.2 μg/L (1.1 to 5.6). No progressive radiolucent lines, osteolysis, or implant loosening signs were observed at the last radiographic evaluation. CONCLUSIONS A large-diameter head ceramic-on-ceramic THA provides outstanding long-term (minimum 10 years) implant survivorship with unrestricted activity while avoiding implant impingement, liner fracture, and hip instability. Functional outcomes, satisfaction, and joint perception were excellent. Although the incidence of squeaking was high, it did not affect patient satisfaction or function. The systemic titanium levels were low, related to unavoidable passive corrosion of implant surfaces, and did not reveal any indirect signs of trunnionosis.
Collapse
Affiliation(s)
- Gautier Beckers
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montreal, QC, Canada
| | - Mina W Morcos
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montreal, QC, Canada
| | - Martin Lavigne
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montreal, QC, Canada; Clinique Orthopédique Duval, Laval, QC, Canada
| | - Vincent Massé
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montreal, QC, Canada; Clinique Orthopédique Duval, Laval, QC, Canada
| | - Marc-Olivier Kiss
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montreal, QC, Canada; Clinique Orthopédique Duval, Laval, QC, Canada
| | - Pascal-André Vendittoli
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montreal, QC, Canada; Clinique Orthopédique Duval, Laval, QC, Canada; Personalized Arthroplasty Society, Atlanta, Georgia
| |
Collapse
|
5
|
Naito Y, Hasegawa M, Tone S, Wakabayashi H, Sudo A. Minimum 7-year results of cementless total hip arthroplasty with vitamin E-diffused and 2-methacryloyloxyethyl phosphorylcholine-grafted highly cross-linked polyethylene. Medicine (Baltimore) 2023; 102:e36257. [PMID: 38050300 PMCID: PMC10695485 DOI: 10.1097/md.0000000000036257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Accepted: 11/01/2023] [Indexed: 12/06/2023] Open
Abstract
The purpose of this study was to evaluate the mid-term clinical results and polyethylene wear of vitamin E-diffused highly cross-linked polyethylene (HXLPE) and 2-methacryloyloxyethyl phosphorylcholine (MPC)-grafted HXLPE in cementless total hip arthroplasty (THA). Thirty-four THAs with vitamin E-diffused HXLPE (VEPE) and 32-mm cobalt-chromium head, and 116 THAs with MPC-grafted HXLPE and 32-mm alumina head were evaluated. The Merle d'Aubigné and Postel scores were administered. Kaplan-Meier survivorship was analyzed. Annual radiographs were analyzed using computerized method and linear steady-state wear rate was measured. The mean duration of follow-up was 9 years (range, 7-11 years) in VEPE group and 8 years (range, 7-10 years) in MPC group. The mean Merle d'Aubigné and Postel scores improved postoperatively in both groups. Kaplan-Meier survivorship with endpoint of revision was 100% (95% confidence interval, 100%-100%) in VEPE group and 98.3% (95% confidence interval, 93.4%-99.6%) in MPC group at 10 years (P = .44). The mean steady-state wear rate was 0.007 mm/year in VEPE group and 0.006 mm/year in MPC group (P = .60). The clinical results of both groups were good and wear rates of both liners were very low.
Collapse
Affiliation(s)
- Yohei Naito
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Masahiro Hasegawa
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Shine Tone
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Hiroki Wakabayashi
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| | - Akihiro Sudo
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
| |
Collapse
|
6
|
Hasegawa M, Tone S, Naito Y, Sudo A. Ultra-High-Molecular-Weight Polyethylene in Hip and Knee Arthroplasties. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2140. [PMID: 36984020 PMCID: PMC10054334 DOI: 10.3390/ma16062140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/12/2023] [Revised: 03/05/2023] [Accepted: 03/06/2023] [Indexed: 06/18/2023]
Abstract
Ultra-high-molecular-weight polyethylene (UHMWPE) wear and particle-induced osteolysis contribute to the failure of total hip arthroplasty (THA) and total knee arthroplasty (TKA). Highly crosslinked polyethylene (HXLPE) was developed in the late 1990s to reduce wear and has shown lower wear rates and loosening than conventional UHMWPE in THA. The irradiation dose for crosslinking is up to 100 kGy. However, during crosslinking, free radical formation induces oxidation. Using HXLPE in THA, the cumulative revision rate was determined to be significantly lower (6.2%) than that with conventional UHMWPE (11.7%) at a mean follow-up of 16 years, according to the Australian Orthopaedic Association National Joint Replacement Registry. However, HXLPE does not confer to TKA the same advantages it confers to THA. Several alternatives have been developed to prevent the release of free radicals and improve polymer mechanical properties, such as thermal treatment, phospholipid polymer 2-methacryloyloxyethyl phosphorylcholine grafting, remelting, and vitamin E addition. Among these options, vitamin E addition has reported good clinical results and wear resistance similar to that of HXLPE without vitamin E, as shown by short-term clinical studies of THA and TKA. This review aims to provide a comprehensive overview of the development and performance of UHMWPE in THA and TKA.
Collapse
|