1
|
Pasqualini I, Rossi LA, Pan X, Denard PJ, Scanaliato JP, Levin JM, Dickens JF, Klifto CS, Hurley ET. High Variability in Standardized Outcome Thresholds of Clinically Important Changes in Shoulder Instability Surgery: A Systematic Review. Arthroscopy 2025; 41:2061-2071.e2. [PMID: 39173689 DOI: 10.1016/j.arthro.2024.07.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Revised: 07/01/2024] [Accepted: 07/30/2024] [Indexed: 08/24/2024]
Abstract
PURPOSE To examine reported minimal clinically important difference (MCID) and patient-acceptable satisfactory state (PASS) values for patient-reported outcome measures (PROMs) after shoulder instability surgery and assess variability in published values depending on the surgery performed. Our secondary aims were to describe the methods used to derive MCID and PASS values in the published literature, including anchor-based, distribution-based, or other approaches, and to assess the frequency of MCID and PASS use in studies on shoulder instability surgery. METHODS A systematic review of MCID and PASS values after Bankart, Latarjet, and Remplissage procedures was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA). The Embase, PubMed, and Cochrane Central Register of Controlled Trials (CENTRAL) databases were queried from 1985 to 2023. Inclusion criteria included studies written in English and studies reporting use of MCID or PASS for patient-reported outcome measures (PROMS) after Latarjet, Bankart, and Remplissage approaches for shoulder instability surgery. Extracted data included study population characteristics, intervention characteristics, and outcomes of interest. Continuous data were described using medians and ranges. Categorical variables, including PROMs and MCID/PASS methods, were described using percentages. Because MCID is a patient-level rather than a group-level metric, the authors confirmed that all included studies reported proportions (%) of subjects who met or exceeded the MCID. RESULTS A total of 174 records were screened, and 8 studies were included in this review. MCID was the most widely used outcome threshold and was reported in all 8 studies, with only 2 studies reporting both the MCID and the PASS. The most widely studied PROMs were the American Shoulder and Elbow Surgeons (range 5.65-9.6 for distribution MCID, 8.5 anchor MCID, 86 anchor PASS); Single Assessment Numeric Evaluation (range 11.4-12.4 distribution MCID, 82.5-87.5 anchor PASS); visual analog scale (VAS) (range 1.1-1.7 distribution MCID, 1.5-2.5 PASS); Western Ontario Shoulder Instability Index (range 60.7-254.9 distribution MCID, 126.43 anchor MCID, 571-619.5 anchor PASS); and Rowe scores (range 5.6-8.4 distribution MCID, 9.7 anchor MCID). Notably, no studies reported on substantial clinical benefit or maximal outcome improvement. CONCLUSIONS Despite the wide array of available PROMs for assessing shoulder instability surgery outcomes, the availability of clinically significant outcome thresholds such as MCID and PASS remains relatively limited. Although MCID has been the most frequently reported metric, there is considerable interstudy variability observed in their values. CLINICAL RELEVANCE Knowing the outcome thresholds such as MCID and PASS of the PROMs frequently used to evaluate the results of glenohumeral stabilization surgery is fundamental because they allow us to know what is a clinically significant improvement for the patient.
Collapse
Affiliation(s)
- Ignacio Pasqualini
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio, U.S.A..
| | | | - Xuankang Pan
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio, U.S.A
| | | | - John P Scanaliato
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois, U.S.A
| | - Jay M Levin
- Division of Hand and Upper Extremity, Department of Orthopedic Surgery, Duke University, Durham, North Carolina, U.S.A
| | - Jonathan F Dickens
- Division of Hand and Upper Extremity, Department of Orthopedic Surgery, Duke University, Durham, North Carolina, U.S.A
| | - Christopher S Klifto
- Division of Hand and Upper Extremity, Department of Orthopedic Surgery, Duke University, Durham, North Carolina, U.S.A
| | - Eoghan T Hurley
- Oregon Shoulder Institute, Medford, Oregon, U.S.A.; Division of Hand and Upper Extremity, Department of Orthopedic Surgery, Duke University, Durham, North Carolina, U.S.A
| |
Collapse
|
2
|
Magnuson JA, Mozes G, Parnes N, Scanaliato JP, Oh LS, Ryan Tyler J, Yeramosu T, Mozes AD. Complications and Return to Sport Between Screw Fixation and Suture Button Fixation for Arthroscopic Latarjet in a 2-year Follow-up: A Retrospective Cohort Study. Orthop J Sports Med 2025; 13:23259671251321501. [PMID: 40171399 PMCID: PMC11960164 DOI: 10.1177/23259671251321501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2024] [Accepted: 10/09/2024] [Indexed: 04/03/2025] Open
Abstract
Background The Latarjet procedure may be performed arthroscopically or via an open approach, utilizing screws or suture buttons for graft fixation. There has been recent interest in suture button techniques in arthroscopic surgery, and proponents assert that these techniques may lead to fewer hardware-related complications while allowing for easier graft positioning. Hypothesis/Purpose This study aimed to compare the complication and return to sports (RTS) rates between screw fixation (SF) and suture button fixation (SB) for patients undergoing the arthroscopic Latarjet procedure. It was hypothesized that each group would have similar outcomes. Study Design Cohort study; Level of evidence, 3. Methods A total of 112 patients underwent arthroscopic Latarjet procedures at a single center between January 2012 and December 2019. All patients had >20% glenoid bone loss, and 11.6% (n = 13) had previous arthroscopic Bankart repair. SF was utilized in 65 (58%) cases, and SB in 47 (42%) cases. Complications, reoperations, and RTS rates were analyzed. Patients were included for analysis if they had a 2-year follow-up and did not require conversion to open surgery. Results Total complications were similar between SF and SB and occurred in 15.4% (n = 10) and 14.9% (n = 7) of cases, respectively (P = .943). Recurrent dislocation was noted in 3.1% (n = 2) of SF cases and 4.3% (n = 2) of SB cases (P = .740). Reoperations were required in 4.6% (n = 3) of the SF group and 4.3% (n = 2) of the SB group (P = .927). There were no hardware complications in the SB group compared with 1 hardware complication in the SF group. RTS was also similar between groups, with 92.3% and 93.6% returning to sports and 75.4% and 80.9% returning to the same level of sports in the SF and SB groups, respectively. Conclusion Graft fixation using SF or SB yielded similar results for arthroscopic Latarjet procedures with respect to complications and RTS. The fixation method may be dictated by surgeon preference without an increased risk of complications.
Collapse
Affiliation(s)
| | | | - Nata Parnes
- Department of Orthopaedic Surgery, Carthage Area Hospital, Carthage, New York, USA
| | - John P. Scanaliato
- Midwest Orthopaedics at Rush University Medical Center, Chicago, Illinois, USA
| | - Luke S. Oh
- Rothman Orthopaedics Florida at Advent Health, Orlando, Florida, USA
| | - John Ryan Tyler
- Department of Orthopaedic Surgery, Carthage Area Hospital, Carthage, New York, USA
| | - Teja Yeramosu
- Rothman Orthopaedics Florida at Advent Health, Orlando, Florida, USA
| | | |
Collapse
|
3
|
Boileau P, Christensen GV, Patterson BM, Nepola JV, Lane CM, Bozoghlian MF, Li X, Galvin JW. Suture Button Fixation in Shoulder Instability Surgery to Achieve Bone Healing: A Critical Analysis Review. JBJS Rev 2024; 12:01874474-202412000-00003. [PMID: 39642250 DOI: 10.2106/jbjs.rvw.24.00165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/08/2024]
Abstract
» Suture button fixation has emerged as an effective surgical construct in arthroscopic and open Latarjet and anterior glenoid reconstruction with free autograft bone with high rates of bone block healing.» Biomechanical data suggest that screw and suture button mechanical fixation constructs provide similar load to failure and stability for the Latarjet procedure.» Preliminary bone healing models have identified that flexible fixation may exhibit a higher degree of bone callus maturation, whereas rigid fixation results in excessive callus hyperplasia» Mechanical tensioner use provides consistent tensioning of suture button constructs and improves bone-to-bone healing rates when used for anterior glenoid reconstruction surgery.» Evidence is lacking regarding the reliability of bone-to-bone healing of allografts to native bone with use of suture button constructs.» Suture button fixation provides good short- and mid-term clinical outcomes for the arthroscopic Latarjet and anterior glenoid reconstruction with free autograft bone.
Collapse
Affiliation(s)
- Pascal Boileau
- ICR - Institut de Chirurgie Réparatrice - Locomoteur & Sports, Institute For Sports and Reconstructive Bone & Joint Surgery, Nice, France
| | - Garrett V Christensen
- Department of Orthopedic Surgery, University of Iowa Hospital and Clinics, Iowa City, Iowa
| | - Brendan M Patterson
- Department of Orthopedic Surgery, University of Iowa Hospital and Clinics, Iowa City, Iowa
| | - James V Nepola
- Department of Orthopedic Surgery, University of Iowa Hospital and Clinics, Iowa City, Iowa
| | - Carter M Lane
- Department of Orthopedic Surgery, University of Iowa Hospital and Clinics, Iowa City, Iowa
| | - Maria F Bozoghlian
- Department of Orthopedic Surgery, University of Iowa Hospital and Clinics, Iowa City, Iowa
| | - Xinning Li
- Department of Orthopedic Surgery, Boston University School of Medicine, Boston Medical Center, Boston, Massachusetts
| | - Joseph W Galvin
- Department of Orthopedic Surgery, University of Iowa Hospital and Clinics, Iowa City, Iowa
| |
Collapse
|
4
|
Shao Z, Jiang Y, Song Q, Wang H, Luo H, Cheng X, Cui G. Short-Term Complications of Arthroscopic Bristow or Latarjet Procedure with Screw Versus Suture-Button Fixation: A Prospective Study of 308 Consecutive Cases by a Single Surgeon. J Bone Joint Surg Am 2024; 106:1776-1784. [PMID: 39325870 DOI: 10.2106/jbjs.23.00390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/28/2024]
Abstract
BACKGROUND This study aimed to investigate the short-term complications (minimum 1-year follow-up) after either an arthroscopic Bristow or Latarjet procedure for anterior shoulder instability utilizing screw or suture-button fixation. METHODS Patients undergoing arthroscopic Bristow or Latarjet procedures between November 2016 and April 2021 were enrolled. Data were collected at baseline, 3 months, 6 months, and every year after surgery. Risks of postoperative complications and unplanned reoperations were assessed. A multivariable regression model was used to identify risk factors for complications and to determine the association of complications with patient-reported outcomes. RESULTS A total of 412 patients (425 shoulders) undergoing arthroscopic Bristow or Latarjet procedures performed by a single surgeon between November 2016 and April 2021 were reviewed. Two hundred and ninety-nine patients (308 shoulders, 76.2% of 404 eligible) with a mean follow-up of 22.3 ± 4.2 months were included for analysis. Two hundred and sixty-nine shoulders (87.3%) underwent a Bristow procedure (165 with screw and 104 with suture-button fixation), while 39 (12.7%) underwent a Latarjet procedure (18 with screw and 21 with suture-button fixation). Eighty-two patients (83 shoulders) reported a total of 85 complications within 2 years after surgery, with an overall complication rate of 26.9%. The rates of recurrent dislocation or subluxation and infection were 1.9% and 0.6%, respectively, while a total of 4 (1.3%) of the shoulders had unplanned reoperations. The most common complications were graft-related (11.7%), followed by complications involving neurologic symptoms (10.7%). The overall, graft, and neurologic complication rates following Bristow or Latarjet procedures were 27.1% versus 25.6%, 12.3% versus 7.7%, and 10.0% versus 15.4%, respectively. Compared with the Bristow technique with screw fixation, Bristow with suture-button fixation yielded a lower risk of any complications (odds ratio [OR], 0.55; p = 0.04). Paying with rural insurance and poor sleep quality prior to surgery were associated with increased risk of any complications. CONCLUSIONS Compared with arthroscopic Bristow procedures with screw fixation, Bristow procedures with suture-button fixation resulted in a lower overall complication risk. Both patient demographic and implant-specific factors were associated with the development of a complication. LEVEL OF EVIDENCE Therapeutic Level II . See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Zhenxing Shao
- Department of Sports Medicine, Institute of Sports Medicine of Peking University, Peking University Third Hospital, Beijing, People's Republic of China
- Beijing Key Laboratory of Sports Injuries, Beijing, People's Republic of China
- Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, People's Republic of China
| | - Yanfang Jiang
- Department of Sports Medicine, Institute of Sports Medicine of Peking University, Peking University Third Hospital, Beijing, People's Republic of China
- Beijing Key Laboratory of Sports Injuries, Beijing, People's Republic of China
- Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, People's Republic of China
| | - Qingfa Song
- Department of Sports Medicine, Institute of Sports Medicine of Peking University, Peking University Third Hospital, Beijing, People's Republic of China
- Beijing Key Laboratory of Sports Injuries, Beijing, People's Republic of China
- Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, People's Republic of China
| | - Hangle Wang
- Department of Sports Medicine, Institute of Sports Medicine of Peking University, Peking University Third Hospital, Beijing, People's Republic of China
- Beijing Key Laboratory of Sports Injuries, Beijing, People's Republic of China
- Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, People's Republic of China
| | - Hao Luo
- Department of Sports Medicine, Institute of Sports Medicine of Peking University, Peking University Third Hospital, Beijing, People's Republic of China
- Beijing Key Laboratory of Sports Injuries, Beijing, People's Republic of China
- Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, People's Republic of China
| | - Xu Cheng
- Department of Sports Medicine, Institute of Sports Medicine of Peking University, Peking University Third Hospital, Beijing, People's Republic of China
- Beijing Key Laboratory of Sports Injuries, Beijing, People's Republic of China
- Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, People's Republic of China
| | - Guoqing Cui
- Department of Sports Medicine, Institute of Sports Medicine of Peking University, Peking University Third Hospital, Beijing, People's Republic of China
- Beijing Key Laboratory of Sports Injuries, Beijing, People's Republic of China
- Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, People's Republic of China
| |
Collapse
|
5
|
Gao A, Song Q, Shao Z, Pan H, Cui G. Inlay structure can improve bone graft stability in the Bristow procedure. J Shoulder Elbow Surg 2024; 33:781-791. [PMID: 37778656 DOI: 10.1016/j.jse.2023.08.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 08/09/2023] [Accepted: 08/27/2023] [Indexed: 10/03/2023]
Abstract
BACKGROUND Compared with the Latarjet procedure, the Bristow procedure has a lower screw-related complication rate but poor bone healing. A modified Inlay Bristow procedure has been reported to significantly improve the bone healing rate, but the biomechanical mechanism is unclear. The aim of this study was to evaluate the biomechanical stability of the bone graft between a modified Inlay Bristow procedure and the classic Bristow procedure. METHODS Sixteen left scapula models (Sawbones, Composite Scapula, and fourth generation) were randomly divided into 2 groups (8:8). The bone graft in the first group was fixed with a 3.5 mm screw using the Inlay structure. The bone graft in the second group was fixed with a 3.5 mm screw via the traditional method. The maximum cyclic displacement, ultimate failure load and stiffness were evaluated biomechanically. The failure type was recorded for each model. RESULTS Cyclic loading tests demonstrated that the maximum cyclic displacement of the Inlay procedure was significantly smaller (P = .001) than that of the classic procedure. The Inlay Bristow technique resulted in a significantly higher (P = .024) ultimate failure load than the classic Bristow technique. The stiffness of the classic group was 19.17 ± 4.01 N/mm and that of the inlay group was 22.34 ± 5.35 N/mm (P = .232). Failure was mainly due to bone graft fractures through the drill hole or glenoid bone fractures. CONCLUSION Inlay Bristow fixation of the bone graft in a Sawbones model provides significantly stronger fixation and better time point zero stability than classic Bristow fixation, suggesting a higher likelihood of graft union.
Collapse
Affiliation(s)
- Aofei Gao
- Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing, China; Beijing Key Laboratory of Sports Injuries, Beijing, China; Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, China; The 2nd Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang Province, China
| | - Qingfa Song
- Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing, China; Beijing Key Laboratory of Sports Injuries, Beijing, China; Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, China
| | - Zhenxing Shao
- Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing, China; Beijing Key Laboratory of Sports Injuries, Beijing, China; Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, China.
| | - Haile Pan
- The 2nd Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang Province, China.
| | - Guoqing Cui
- Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing, China; Beijing Key Laboratory of Sports Injuries, Beijing, China; Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, China.
| |
Collapse
|
6
|
Raiss P, Campagnoli A, Bachmaier S, Anderl M, Wittmann T. The Subscapularis-Sparing "Flipped Latarjet" Procedure. Arthrosc Tech 2024; 13:102899. [PMID: 38690334 PMCID: PMC11056617 DOI: 10.1016/j.eats.2023.102899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Accepted: 11/30/2023] [Indexed: 05/02/2024] Open
Abstract
The Latarjet procedure is a proven and effective operation to treat anterior shoulder instability. Especially in cases with anterior glenoid bone loss, the Latarjet operation is the most popular procedure to restore glenoid anatomy and avoid further dislocations. Next to the re-creation of the missing glenoid bone, the sling effect of the conjoint tendon transferred between a split in the subscapularis muscle is an important "soft tissue stabilizer" of the humeral head. However, it has been shown that the inferior part of the subscapularis muscle tends to degenerate, leading to fatty infiltration of the muscle itself. Also, exposure through the subscapularis split is technically demanding, and there is a risk of nerve damage due to the pulling forces of the retractors during open surgery. When performing the procedure arthroscopically, extremely low and medial portals are necessary to find a correct angle for the glenoid drilling when approaching from anterior. Neurovascular structures may be at risk during these surgical steps. The aim of the flipped Latarjet procedure is to facilitate a safe and reliable arthroscopic operation to anteriorly stabilize the shoulder by transferring the coracoid to the deficient glenoid without splitting the subscapularis muscle while keeping the benefits of a sling effect of the conjoined tendon.
Collapse
Affiliation(s)
| | | | | | | | - Thomas Wittmann
- Department for Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital LMU Munich, Munich, Germany
| |
Collapse
|
7
|
Paul K, Elphingstone JW, Williams M, Manfredi JN, Jardaly A, Schick S, Floyd S, Brabston EW, Momaya AM, Ponce BA. Suspensory fixation for bone transfer procedures in shoulder instability is superior to screws in an angled construct: a biomechanical analysis. JSES Int 2024; 8:250-256. [PMID: 38464447 PMCID: PMC10920126 DOI: 10.1016/j.jseint.2023.09.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2024] Open
Abstract
Background The Latarjet procedure is a common bony augmentation procedure for anterior shoulder instability. Historically, screw fixation is used to secure the coracoid graft to the anterior glenoid surface; however, malpositioning of the graft leads to oblique screw insertion that contributes to complications. Suture buttons (SBs) are a more recent fixation technique that have not been studied alongside standard screw fixation in the context of biomechanical models of angulated fixation. This study aims to compare the biomechanical strength of single and double, screw and SB fixation at various levels of angulation. Methods Testing was performed using polyurethane models from Sawbones. The graft piece was secured with screw fixation (Arthrex, Naples, FL, USA) or suspensory button (ABS Tightrope, Arthrex, Naples, FL, USA). Single or double constructs of screws and SBs were affixed at 0°, 15°, and 30° angles to the face of the glenoid component. An aluminum testing jig held the samples securely while a materials testing system applied loads. Five constructs were used for each condition and assessed load to failure testing. Results For single fixation constructs, suspensory buttons were 60% stronger than screws at 0° (P < .001), and 52% stronger at 15° (P = .004); however, at 30°, both were comparable (P = .180). Interestingly, single suspensory button at 15° was equivalent to a single screw at 0° (P = .310). For double fixation, suspensory buttons (DT) were 32% stronger than screws at 0° (P < .001) and 35% stronger than screws at 15° (P < .001). Both double fixation methods were comparable at 30° (P = .061). Suspensory buttons at 15° and 30° were equivalent to double screws at 0 (P = .280) and 15° (P = .772), respectively. Conclusion These measurements indicate that the suspensory button has a significantly higher load to failure capacity over the screw fixation technique, perpendicularly and with up to 15° of angulation. These analyses also indicate that the suspensory button fixation offers superior strength even when positioned more obliquely than the screw fixation. Therefore, suspensory button fixation may confer more strength while offering greater margin for error when positioning the graft.
Collapse
Affiliation(s)
- Kyle Paul
- Department of Orthopedic Surgery, University of Texas Health San Antonio, San Antonio, TX, USA
| | - Joseph W. Elphingstone
- Department of Orthopedic Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Marshall Williams
- Department of Orthopedic Surgery, The Hughston Clinic, Columbus, GA, USA
| | - John N. Manfredi
- Department of Orthopedic Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Achraf Jardaly
- Department of Orthopedic Surgery, The Hughston Clinic, Columbus, GA, USA
| | - Samuel Schick
- Department of Orthopedic Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Susan Floyd
- Department of Orthopedic Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Eugene W. Brabston
- Department of Orthopedic Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Amit M. Momaya
- Department of Orthopedic Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Brent A. Ponce
- Department of Orthopedic Surgery, The Hughston Clinic, Columbus, GA, USA
| |
Collapse
|
8
|
Billaud A, Baverel L, Metais P. Arthroscopic Latarjet yields better union and prevention of instability compared to arthroscopic bony Bankart repair in shoulders with recurrent anterior instability: a systematic review. Knee Surg Sports Traumatol Arthrosc 2023; 31:5994-6005. [PMID: 37980282 DOI: 10.1007/s00167-023-07655-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Accepted: 10/24/2023] [Indexed: 11/20/2023]
Abstract
PURPOSE To determine whether arthroscopic Latarjet procedure or arthroscopic bony Bankart repair provide better outcomes in terms of rates of recurrent instability, non-union and complications, as well as clinical scores and range of motion. METHODS An electronic literature search was performed using PubMed, Embase®, and Cochrane databases, applying the following keywords: "Arthroscopic bony Bankart" OR "Arthroscopic osseous Bankart" AND "Arthroscopic Latarjet" OR "Arthroscopic coracoid bone block". RESULTS The systematic search returned 1465 records, of which 29 were included (arthroscopic bony Bankart repair, n = 16; arthroscopic Latarjet, n = 13). 37 datasets were included for data extraction, on 1483 shoulders. Compared to arthroscopic Latarjet, arthroscopic bony Bankart repair had significantly higher instability rates (0.14; CI 0.10-0.18; vs 0.04; CI 0.02-0.06), significantly lower union rates (0.63; CI 0.28-0.91 vs 0.98; CI 0.93-1.00), and significantly lower pain on VAS (0.42; CI 0.17-0.67 vs 1.17; CI 0.96-1.38). There were no significant differences in preoperative glenoid bone loss, follow-up, complication rate, ROWE score, ASES score, external rotation, and anterior forward elevation between arthroscopic Latarjet and arthroscopic bony Bankart repair. CONCLUSION Compared to arthroscopic Latarjet, arthroscopic bony Bankart repair results in significantly (i) higher rates of recurrent instability (14% vs 4%), (ii) lower union rates (63% vs 98%), but (iii) slightly lower pain on VAS (0.45 vs 1.17). There were no differences in complication rates, clinical scores, or postoperative ranges of motion. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Anselme Billaud
- Clinique du Sport, 2 rue Georges Negrevergne, 33700, Mérignac, France
| | | | - Pierre Metais
- Hopital Prive de la Châtaigneraie, ELSAN, Clermont-Ferrand, France
| |
Collapse
|
9
|
Song Q, Gao A, Bai J, Shao Z, Cui G. The Arthroscopic Bristow Procedure Is Superior to the Arthroscopic Latarjet Procedure in Return to Sports but Inferior in Graft Healing: A Comparative Study With 3.4-Year Follow-Up. Arthroscopy 2023; 39:2423-2433. [PMID: 37270110 DOI: 10.1016/j.arthro.2023.05.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2022] [Revised: 05/13/2023] [Accepted: 05/18/2023] [Indexed: 06/05/2023]
Abstract
PURPOSE To compare clinical and computed tomography outcomes between the arthroscopic Latarjet procedure and the arthroscopic Bristow procedure. METHODS Patients who underwent arthroscopic Latarjet or Bristow procedures with at least 2 years of follow-up were retrospectively reviewed. Thirty-eight shoulders were included in the Latarjet group, and 34 were included in the Bristow group. Recurrence of dislocation, clinical scores, rate of return to sports (RTS), and computed tomography assessment findings (position of transferred coracoid, graft healing, graft absorption, and glenohumeral degenerative osteoarthritis [OA]) were obtained at final follow-up. RESULTS No recurrent dislocation occurred in either group, and no significant differences in clinical scores were found between the 2 procedures, with a mean follow-up period of 3.4 years. The operative time in the Bristow group was significantly shorter than that in the Latarjet group (P < .001). The transferred coracoid had healed in 94.7% of the patients in the Latarjet group and 85.3% in the Bristow group at final follow-up (P = .01). No significant difference in graft absorption or the degree of glenohumeral OA was detected between the 2 groups. However, moderate to severe OA only occurred in the Latarjet group at final follow-up (4 of 38 shoulders, 10.5%). The postoperative external rotation angle and level of RTS favored the Latarjet procedure (P = .030 and P = .034, respectively). CONCLUSIONS Both the arthroscopic Latarjet and arthroscopic Bristow procedures led to good clinical scores with no new dislocation episodes. The Bristow group showed significantly less graft healing than the Latarjet group. However, the arthroscopic Bristow procedure took less operative time and showed a lower rate of early moderate to severe glenohumeral OA, better range of motion, and a higher rate of RTS. LEVEL OF EVIDENCE Level III, retrospective comparative therapeutic trial.
Collapse
Affiliation(s)
- Qingfa Song
- Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing Key Laboratory of Sports Injuries, Beijing, China
| | - Aofei Gao
- Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing Key Laboratory of Sports Injuries, Beijing, China
| | - Jucheng Bai
- Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing Key Laboratory of Sports Injuries, Beijing, China
| | - Zhenxing Shao
- Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing Key Laboratory of Sports Injuries, Beijing, China
| | - Guoqing Cui
- Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing Key Laboratory of Sports Injuries, Beijing, China.
| |
Collapse
|
10
|
Manfredi JN, Schick S, Paul KD, Elphingstone JW, Sowell J, Lameka M, Brabston EW, Momaya AM, Ponce BA. A Systematic Review of Screw and Suture Button Glenoid Augmentation Constructs. Orthop J Sports Med 2023; 11:23259671231186429. [PMID: 37840899 PMCID: PMC10571685 DOI: 10.1177/23259671231186429] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 04/11/2023] [Indexed: 10/17/2023] Open
Abstract
Background Glenohumeral dislocations often lead to glenoid bone loss and recurrent instability, warranting bony augmentation. While numerous biomechanical studies have investigated fixation methods to secure a graft to the glenoid, a review of available constructs has yet to be performed. Purpose To synthesize the literature and compare the biomechanics of screw and suture button constructs for anterior glenoid bony augmentation. Study Design Systematic review. Methods A systematic review was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. There were 2 independent reviewers who performed a literature search using the PubMed, Embase, and Google Scholar databases of studies published between 1950 and 2020. Studies were included that compared the biomechanical outcomes of fixation for the treatment of anterior shoulder instability with glenoid bone loss. Results Overall, 13 of the 363 studies screened met the inclusion criteria. The included studies measured the biomechanical strength of screws or suture buttons on a cadaveric or synthetic Latarjet construct. Screws and suture buttons were biomechanically similar, as both constructs exhibited comparable loads at failure and final displacement. Screw type (diameter, threading, or composition) did not significantly affect construct strength, and double-screw fixation was superior to single-screw fixation. Additionally, 2 screws augmented with a small plate had a higher load at failure than screws that were not augmented. Unicortical double-screw fixation was inferior to bicortical double-screw fixation, although construct strength did not significantly decrease if 1 of these screws was unicortical. Further, 2 screws inserted at 15° off axis experienced significantly higher graft displacement and lower ultimate failure loads than those inserted at 0° parallel to the glenoid. Conclusion Suture buttons provided comparable strength to screws and offer an effective alternative to reduce screw-related complications. Augmentation with a small plate may clinically enhance construct strength and decrease complications through the dispersion of force loads over a greater surface area. Differences in screw type did not appear to alter construct strength, provided that screws were placed parallel to the articular surface and were bicortical.
Collapse
Affiliation(s)
- John N. Manfredi
- Department of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Samuel Schick
- Department of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Kyle D. Paul
- University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
| | - Joseph W. Elphingstone
- Department of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Josiah Sowell
- Department of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Megan Lameka
- Department of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Eugene W. Brabston
- Department of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Amit M. Momaya
- Department of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | | |
Collapse
|
11
|
Bockmann B, Nebelung W, Gröger F, Leuzinger J, Agneskirchner J, Brunner U, Seybold D, Streich J, Bartsch S, Schicktanz K, Maier D, Königshausen M, Patzer T, Venjakob AJ. The arthroscopic treatment of anterior shoulder instability with glenoid bone loss shows similar clinical results after Latarjet procedure and iliac crest autograft transfer. Knee Surg Sports Traumatol Arthrosc 2023; 31:4566-4574. [PMID: 37386197 DOI: 10.1007/s00167-023-07480-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 06/02/2023] [Indexed: 07/01/2023]
Abstract
PURPOSE Recurrent anterior shoulder instability caused by critical bone loss of the glenoid is a challenging condition for shoulder surgeons. The purpose of this prospective multicenter trial was to compare the arthroscopic transfer of the coracoid process (Latarjet procedure) with the arthroscopic reconstruction of the glenoid using iliac crest autografts. METHODS A prospective multi-center trial was performed in nine orthopaedic centres in Austria, Germany and Switzerland between July 2015 and August 2021. Patients were prospectively enrolled and received either an arthroscopic Latarjet procedure or an arthroscopic iliac crest graft transfer. Standardized follow-up after 6 months and mimimum 24 months included range of motion, Western Ontario stability index (WOSI), Rowe score and subjective shoulder value (SSV). All complications were recorded. RESULTS 177 patients (group Latarjet procedure: n = 110, group iliac crest graft: n = 67) were included in the study. WOSI (n.s.), SSV (n.s.) and Rowe score (n.s.) showed no difference at final follow-up. 10 complications were seen in group Latarjet procedure and 5 in group iliac crest graft; the frequency of complications did not differ between the two groups (n.s.). CONCLUSION The arthrosopic Latarjet procedure and arthroscopic iliac crest graft transfer lead to comparable results regarding clinical scores, frequency of recurrent dislocations and complication rates. LEVEL OF EVIDENCE Level II.
Collapse
Affiliation(s)
- Benjamin Bockmann
- Department of Orthopaedics and Trauma Surgery, St. Josef Hospital, Ruhr University, Gudrunstraße 56, 44791, Bochum, Germany.
- Department of Shoulder and Elbow Surgery, St. Josef Krankenhaus Essen-Kupferdreh, Essen, Germany.
| | | | - Falk Gröger
- Shouldercare, Engeriedspital, Bern, Switzerland
| | - Jan Leuzinger
- Center for Minimally Invasive Surgery, Etzelclinic, Pfäffikon, Switzerland
| | | | - Ulrich Brunner
- Trauma and Orthopaedic Surgery, Krankenhaus Agatharied, Hausham, Germany
| | | | - Jörg Streich
- Department of Shoulder and Elbow Surgery, St. Josef Krankenhaus Essen-Kupferdreh, Essen, Germany
| | - Stefan Bartsch
- Schaumburg Centre of Joint Surgery, Praxis am Wall Rinteln, Rinteln, Germany
| | | | - Dirk Maier
- Department of Orthopaedics and Trauma Surgery, University Hospital Basel, Basel, Switzerland
| | - Matthias Königshausen
- Department of General and Trauma Surgery, BG University Hospital Bergmannsheil, Bochum, Germany
| | - Thilo Patzer
- Centre for Shoulder, Elbow, Knee and Sports Orthopedics, Schön-Klinik, Düsseldorf, Germany
| | | |
Collapse
|