1
|
Antonopoulos AS, Odutayo A, Oikonomou EK, Trivella M, Petrou M, Collins GS, Antoniades C. Development of a risk score for early saphenous vein graft failure: An individual patient data meta-analysis. J Thorac Cardiovasc Surg 2020; 160:116-127.e4. [PMID: 31606176 PMCID: PMC7322547 DOI: 10.1016/j.jtcvs.2019.07.086] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Revised: 06/24/2019] [Accepted: 07/08/2019] [Indexed: 12/23/2022]
Abstract
OBJECTIVES Early saphenous vein graft (SVG) occlusion is typically attributed to technical factors. We aimed at exploring clinical, anatomical, and operative factors associated with the risk of early SVG occlusion (within 12 months postsurgery). METHODS Published literature in MEDLINE was searched for studies reporting the incidence of early SVG occlusion. Individual patient data (IPD) on early SVG occlusion were used from the SAFINOUS-CABG Consortium. A derivation (n = 1492 patients) and validation (n = 372 patients) cohort were used for model training (with 10-fold cross-validation) and external validation respectively. RESULTS In aggregate data meta-analysis (48 studies, 41,530 SVGs) the pooled estimate for early SVG occlusion was 11%. The developed IPD model for early SVG occlusion, which included clinical, anatomical, and operative characteristics (age, sex, dyslipidemia, diabetes mellitus, smoking, serum creatinine, endoscopic vein harvesting, use of complex grafts, grafted target vessel, and number of SVGs), had good performance in the derivation (c-index = 0.744; 95% confidence interval [CI], 0.701-0.774) and validation cohort (c-index = 0.734; 95% CI, 0.659-0.809). Based on this model. we constructed a simplified 12-variable risk score system (SAFINOUS score) with good performance for early SVG occlusion (c-index = 0.700, 95% CI, 0.684-0.716). CONCLUSIONS From a large international IPD collaboration, we developed a novel risk score to assess the individualized risk for early SVG occlusion. The SAFINOUS risk score could be used to identify patients that are more likely to benefit from aggressive treatment strategies.
Collapse
Affiliation(s)
- Alexios S Antonopoulos
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom
| | - Ayodele Odutayo
- Centre for Statistics in Medicine, University of Oxford, Oxford, United Kingdom
| | - Evangelos K Oikonomou
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom
| | - Marialena Trivella
- Centre for Statistics in Medicine, University of Oxford, Oxford, United Kingdom
| | - Mario Petrou
- Department of Cardiac Surgery, John Radcliffe Hospital, Oxford University Hospitals NHS Trust, Oxford, United Kingdom
| | - Gary S Collins
- Centre for Statistics in Medicine, University of Oxford, Oxford, United Kingdom
| | - Charalambos Antoniades
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom.
| |
Collapse
|
2
|
Dual SA, Muller A, Boës S, Brinkmann O, Steffanoni S, Falk V, Meboldt M, Schmid Daners M, Sündermann S. ConVes: The Sutureless Aortic Graft Anastomotic Device. Ann Thorac Surg 2018. [PMID: 29530280 DOI: 10.1016/j.athoracsur.2017.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
PURPOSE Less invasive left ventricular assist device implantation became feasible with the development of smaller devices. This study evaluated a sutureless aortic anastomosis device to facilitate the implant procedure. DESCRIPTION The novel anastomotic device deploys and anchors an acute-angled stent in the aortic wall to create a sutureless outflow graft anastomosis in the ascending aorta. Four aortic anastomoses were performed on the beating hearts of two pigs without cross-clamping or cardiopulmonary bypass. EVALUATION The procedure was fast and simple. The time of anastomosis averaged 8.1 minutes, with merely oral instructions to the operating surgeon. The design of the stent allowed the outflow graft to be implanted with the intended angulation of 45 degrees. CONCLUSIONS This proof-of-concept study demonstrates the feasibility and short-term success of the proposed sutureless anastomotic device. Further preclinical studies are necessary to evaluate long-term durability of the anastomosis.
Collapse
Affiliation(s)
- Seraina Anne Dual
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland.
| | - Alissa Muller
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Stefan Boës
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Oliver Brinkmann
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Séline Steffanoni
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Volkmar Falk
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
| | - Mirko Meboldt
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Marianne Schmid Daners
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Simon Sündermann
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
| |
Collapse
|
3
|
Vokrri L, Qavdarbasha A, Rudari H, Ahmetaj H, Manxhuka-Kërliu S, Hyseni N, Porcu P, Cinquin P, Sessa C. Experimental study of sutureless vascular anastomosis with use of glued prosthesis in rabbits. Vasc Health Risk Manag 2015; 11:211-7. [PMID: 25848302 PMCID: PMC4383148 DOI: 10.2147/vhrm.s73104] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE The objective of this study is to explore the feasibility and efficacy of a new technique for sutureless vascular anastomosis, using glued prosthesis, as a sole anastomosis fixation method in rabbits. METHODS Ten rabbits were randomly selected to conduct the experiment. Five rabbits underwent direct anastomosis of infrarenal abdominal aorta, with glued prosthesis. In five other rabbits, reconstruction was done by sutured anastomosis. All animals were immediately examined by echo-Doppler for patency of anastomosis. The burst pressure of the glued anastomosis was measured and compared with that of a sutured artery. The animals were euthanized, and tissue samples were taken for histological examination immediately after the experiment. RESULTS Compared to conventional anastomoses, sutureless vascular anastomoses required shorter time of creation and significantly reduced blood loss (P<5%). There was no significant difference on the average blood flow through the anastomosis between two groups at the end of surgery. All anastomoses with glued prosthesis, examined by echo-Doppler, were patent at the anastomotic site, except one, which was stenosed immediately after surgery. In the control group, except one with stenosis, all conventional anastomoses were patent. Mean burst pressure at the anastomotic site for sutureless anastomoses was lower than in control group. Macroscopically, the BioGlue did not demonstrate any adhesion to the surrounding tissue as it was covered by the vascular prosthesis. Histological examination showed low-grade inflammatory reaction in glued anastomoses versus no inflammatory reaction at the sutured anastomoses. CONCLUSION This technique may provide a feasible and successful alternative in vascular surgery. However, further long-term studies are necessary to elucidate the break pressure and degree of inflammation at the anastomotic site.
Collapse
Affiliation(s)
- Lulzim Vokrri
- Department of Vascular Surgery, University Clinical Center of Kosovo, Republic of Kosovo
- Medical Faculty, University of Pristina, Republic of Kosovo
- Veterinary Institute, Pristina, Republic of Kosovo
- University of Grenoble Alpes/CNRS/TIMC-IMAG UMR 5525 (GMCAO team), Grenoble, 38000, France
| | - Arsim Qavdarbasha
- Department of Vascular Surgery, University Clinical Center of Kosovo, Republic of Kosovo
- Medical Faculty, University of Pristina, Republic of Kosovo
- Veterinary Institute, Pristina, Republic of Kosovo
| | - Hajriz Rudari
- Department of Vascular Surgery, University Clinical Center of Kosovo, Republic of Kosovo
- Medical Faculty, University of Pristina, Republic of Kosovo
- Veterinary Institute, Pristina, Republic of Kosovo
| | - Halil Ahmetaj
- Department of Vascular Surgery, University Clinical Center of Kosovo, Republic of Kosovo
- Medical Faculty, University of Pristina, Republic of Kosovo
- Veterinary Institute, Pristina, Republic of Kosovo
| | - Suzana Manxhuka-Kërliu
- Department of Vascular Surgery, University Clinical Center of Kosovo, Republic of Kosovo
- Medical Faculty, University of Pristina, Republic of Kosovo
- Veterinary Institute, Pristina, Republic of Kosovo
| | - Nexhmi Hyseni
- Department of Vascular Surgery, University Clinical Center of Kosovo, Republic of Kosovo
- Medical Faculty, University of Pristina, Republic of Kosovo
- Veterinary Institute, Pristina, Republic of Kosovo
| | - Paolo Porcu
- Department of Vascular Surgery, University Clinical Center of Grenoble, Grenoble, 38000, France
| | - Philippe Cinquin
- Department of Vascular Surgery, University Clinical Center of Grenoble, Grenoble, 38000, France
- University of Grenoble Alpes/CNRS/TIMC-IMAG UMR 5525 (GMCAO team), Grenoble, 38000, France
| | - Carmine Sessa
- Department of Vascular Surgery, University Clinical Center of Grenoble, Grenoble, 38000, France
- University of Grenoble Alpes, Grenoble 38000, France
| |
Collapse
|
4
|
Bassano C, Bovio E, Sperandio M, Uva F, Farinaccio A, Prati P, Chiariello L. Five-year clinical outcome and patency rate of device-dependent venous grafts after clampless OPCAB with PAS-port automated proximal anastomosis: the PAPA Study. J Card Surg 2014; 29:325-32. [PMID: 24883445 DOI: 10.1111/jocs.12274] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To evaluate long-term clinical performance and angiographic patency of automated proximal venous anastomoses following clampless coronary artery bypass (C-CAB). METHODS Observational study in patients submitted for isolated C-CAB and at least one proximal aortosaphenous anastomosis performed with an automated connector (Cardica PAS-Port) including 152 consecutive patients (165 devices and 199 device-dependent distal anastomoses), with LVEF > 30% and saphenous vein diameter of 4-6 mm. Clinical follow-up was 96% complete (4101/4269 pt-months). Graft patency rate was assessed with 64-slice CT-scan or coronary angiography. Freedom from major adverse cardiac and cerebrovascular events (MACCE) was reported as actuarial probability with 95% confidence limits and venous graft patency as actual rate at every year interval. RESULTS Early operative mortality was 1.9%; incidence of neurologic injury was zero. Freedom from MACCE was 92.7 ± 2.1 at one year and 85.2 ± 4.8 at five years. The actual patency rate of device-dependent venous grafts was 90%, 85%, 84%, 84%, and 93% for one-, two-, three-, four-, and five-year-old grafts, respectively. CONCLUSIONS The device is a well-performing system for proximal anastomoses. The incidence of neurologic complications seems to be reduced with this clampless approach. The high patency rate is stable over time.
Collapse
|
5
|
Bergsland J. Safe introduction and quality control of new methods in coronary surgery. Acta Inform Med 2011; 19:203-15. [PMID: 23408734 PMCID: PMC3564183 DOI: 10.5455/aim.2011.19.203-215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2011] [Accepted: 12/25/2011] [Indexed: 11/04/2022] Open
Abstract
Introduction: The first part of the paper analyses off pump coronary bypass surgery (OPCAB), which is compared with traditional on-pump procedures (ONCAB). Furthermore ,the paper evaluates the use of a new automatic device for performance of the proximal anastomosis and finally the effect of intracoronary shunt on myocardial ischemia during OPCAB. The main goal of the paper is to demonstrate the importance of careful clinical studies during introduction of the new techniques in cardiac surgery. Methods: Statistical analysis was performed on a large clinical database from Buffalo, NY, USA comparing OPCAB and ONCAB. Subsequently, a sequential controlled clinical study compared patients operated with a new automatic connector device to patients operated with classic suture technique. Finally a randomized study was performed to evaluate the effect of the use of an intracoronary shunt during construction of distal anastomosis. Results: The studies from Buffalo demonstrated reduced complications rates in high risk patients when OPCAB techniques were used. The use of connector devices in saphenous venous anastomosis was clearly inferior to standard technique. Intracoronary shunt was found to be beneficial by preventing ischemia. Discussion: Numerous studies have studied the results of OPCAB vs ONCAB and although results are variable it seems that OPCAB is advantageous in high risk patients, while in low risk patients there are much less if any benefit. The results of the studies of connector devices caused the product to be taken off the market. The value of shunt in OPCAB was clearly demonstrated by the randomized studies. Conclusion: The investigations presented in this paper clearly demonstrates the importance of well-designed studies when new surgical methods are introduced. In the present period of rapid technological development, carefully controlled, un-biased clinical trials are crucial to preserve patient safety and avoid unjustified societal cost.
Collapse
Affiliation(s)
- Jacob Bergsland
- The Interventional Centre, Oslo University Hospital, Oslo, Norway ; BH Heart Centre, Tuzla, Bosnia and Herzegovina
| |
Collapse
|
6
|
Hillis LD, Smith PK, Anderson JL, Bittl JA, Bridges CR, Byrne JG, Cigarroa JE, Disesa VJ, Hiratzka LF, Hutter AM, Jessen ME, Keeley EC, Lahey SJ, Lange RA, London MJ, Mack MJ, Patel MR, Puskas JD, Sabik JF, Selnes O, Shahian DM, Trost JC, Winniford MD. 2011 ACCF/AHA Guideline for Coronary Artery Bypass Graft Surgery. A report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. Developed in collaboration with the American Association for Thoracic Surgery, Society of Cardiovascular Anesthesiologists, and Society of Thoracic Surgeons. J Am Coll Cardiol 2011; 58:e123-210. [PMID: 22070836 DOI: 10.1016/j.jacc.2011.08.009] [Citation(s) in RCA: 582] [Impact Index Per Article: 41.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
7
|
Hillis LD, Smith PK, Anderson JL, Bittl JA, Bridges CR, Byrne JG, Cigarroa JE, Disesa VJ, Hiratzka LF, Hutter AM, Jessen ME, Keeley EC, Lahey SJ, Lange RA, London MJ, Mack MJ, Patel MR, Puskas JD, Sabik JF, Selnes O, Shahian DM, Trost JC, Winniford MD, Winniford MD. 2011 ACCF/AHA Guideline for Coronary Artery Bypass Graft Surgery: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. Circulation 2011; 124:e652-735. [PMID: 22064599 DOI: 10.1161/cir.0b013e31823c074e] [Citation(s) in RCA: 390] [Impact Index Per Article: 27.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
8
|
Demertzis S, Trunfio R, Faletra F, Wyttenbach R, Siclari F. Sutureless proximal anastomosis using the PAS-Port system: six-month patency and five-year follow-up in "all-comers". Ann Thorac Surg 2010; 90:1507-13. [PMID: 20971250 DOI: 10.1016/j.athoracsur.2010.06.101] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2009] [Revised: 06/14/2010] [Accepted: 06/16/2010] [Indexed: 11/25/2022]
Abstract
BACKGROUND The PAS-Port system (Cardica, Inc, Redwood City, CA) was used routinely for patients undergoing coronary surgery with at least one venous graft. Graft patency and clinical results were evaluated, respectively, at 6 months and 5 years after surgery. METHODS A total of 100 patients (82 males, 18 females; mean age 68.9 ± 12 years) underwent coronary bypass surgery with at least one PAS-Port anastomosis (total number of PAS-Port implants: n = 117). At 6 months after surgery all patients were followed up clinically and 86 patients with 101 PAS-Port implants underwent either a multidetector computed tomographic scan or coronary angiography. Actuarial freedom from MACCE (major adverse cardiac and cerebrovascular events) was assessed at 5 years after surgery. RESULTS Six-month PAS-Port patency was 88%. The inner diameter of the graft at the implant site (measured in 26 patients) did not reveal any pathologic narrowing (mean inner diameter 3.1 ± 0.6 mm). At 5 years, freedom from overall MACCE was 79% ± 5% and freedom from PAS-Port target vessel revascularization was 94% ± 6%. CONCLUSIONS The routine use of PAS-Port was associated with good vein graft patency at 6 months and a low incidence of MACCE at 5 years after surgery. No evidence of implant-related graft stenosis was detected.
Collapse
Affiliation(s)
- Stefanos Demertzis
- Department of Cardiac Surgery, Cardiocentro Ticino, Lugano, Switzerland.
| | | | | | | | | |
Collapse
|
9
|
Yamaguchi S, Watanabe G, Tomita S, Ohtake H, Nagamine H, Iino K. Use of skeletonized radial artery graft with the PAS-Port proximal anastomotic device. Ann Thorac Surg 2009; 87:1910-3. [PMID: 19463618 DOI: 10.1016/j.athoracsur.2008.12.094] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2007] [Revised: 12/28/2008] [Accepted: 12/30/2008] [Indexed: 11/19/2022]
Abstract
PURPOSE We report our initial experience with the PAS-Port proximal anastomosis system (Cardica Inc, Redwood City, CA) using full-skeletonized radial artery (RA) in patients requiring off-pump coronary artery bypass grafting. DESCRIPTION The PAS-Port system (Cardica Inc) was used in 25 patients undergoing off-pump coronary artery bypass surgery. All patients received at least one RA graft using the PAS-Port system on the proximal anastomosis. The radial arteries were harvested in a fully skeletonized fashion before loading to the PAS-Port system. EVALUATION Our attempt to use the PAS-Port system for proximal anastomosis of the RA was successful in 25 anastomoses. Postoperative angiography showed 24 grafts to be widely patent. During the mean postoperative follow-up of 9.2 +/- 3.1 months, there was no cardiac-related event in any patient. Mid-term patency collected from the first 8 patients was 87.5% (mean follow-up, 12.8 +/- 2.8 months). CONCLUSIONS The PAS-Port system does not require aortic clamping and enables the creation of uniform and widely patent anastomosis with use of RA grafts.
Collapse
Affiliation(s)
- Shohjiro Yamaguchi
- Department of General and Cardiothoracic Surgery, Kanazawa University School of Medicine, Kanazawa, Japan.
| | | | | | | | | | | |
Collapse
|
10
|
Shimokawa T, Manabe S, Sawada T, Matsuyama S, Fukui T, Takanashi S. Intermediate-Term Patency of Saphenous Vein Graft With a Clampless Hand-Sewn Proximal Anastomosis Device After Off-pump Coronary Bypass Grafting. Ann Thorac Surg 2009; 87:1416-20. [DOI: 10.1016/j.athoracsur.2009.02.090] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2008] [Revised: 02/26/2009] [Accepted: 02/27/2009] [Indexed: 11/26/2022]
|
11
|
Fujii T, Watanabe Y, Shiono N, Ozawa T, Hamada S, Masuhara H, Teramoto C, Hara M, Koyama N. Study of coronary artery bypass using the PAS-Port device: assessment by multidetector computed tomography. Gen Thorac Cardiovasc Surg 2009; 57:79-86. [PMID: 19214448 DOI: 10.1007/s11748-008-0334-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2008] [Accepted: 09/12/2008] [Indexed: 11/29/2022]
Abstract
OBJECTIVE The use of automatic anastomotic devices in coronary artery bypass grafting surgery is associated with lower patency rates in comparison to conventional anastomosis methods. This is thought to be caused by graft curvature occurring after closing of the chest wall. METHODS We evaluated 39 grafts in 28 patients who underwent off-pump coronary artery bypass surgery using the PAS-Port. After surgery, the proximal anastomotic angle of each stent, graft morphology, and patency were evaluated with axial and sagittal views. RESULTS The angle for the left anterior descending coronary artery segment was relatively obtuse on the left side of the ascending aorta, and the graft loop formation was not necessary. The angle for the left circumflex coronary artery segment was significantly acute for anastomosis from the upper left side of the ascending aorta. Because grafts are under the constraints of a large loop, graft length tended to become easily excessive or deficient. The angle for the right coronary artery segment was relatively obtuse. The space on the right side of the heart was so narrow that in some cases we had difficulty setting out the appropriate graft location to prevent graft curvature. No bending or stenosis was present in any graft, showing a patency rate of 100%. CONCLUSION The short-term results of coronary bypass grafting using PAS-Port are satisfactory.
Collapse
Affiliation(s)
- Takeshiro Fujii
- Division of Cardiovascular Surgery, Department of Surgery, School of Medicine, Faculty of Medicine, Toho University, 6-11-1 Omorinishi, Ota-ku, Tokyo 143-8541, Japan.
| | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Kai M, Hanyu M, Soga Y, Nomoto T, Nakano J, Matsuo T, Kawato M, Okabayashi H. Midterm patency rate after saphenous vein grafting with a PAS-Port device. J Thorac Cardiovasc Surg 2009; 137:503-4. [PMID: 19185178 DOI: 10.1016/j.jtcvs.2008.03.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2007] [Revised: 01/29/2008] [Accepted: 03/02/2008] [Indexed: 11/26/2022]
Affiliation(s)
- Masashi Kai
- Department of Cardiovascular Surgery, Kokura Memorial Hospital, Fukuoka, Japan
| | | | | | | | | | | | | | | |
Collapse
|
13
|
The Current Status of Anastomotic Devices for Coronary Artery Bypass Surgery. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2009; 4:9-12. [DOI: 10.1097/imi.0b013e318198dc6d] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
The purpose of this article is to briefly review the history of proximal and distal anastomotic devices and to discuss presently available devices. Clinical outcome data from the EPIC Trial of the Cardica PAS-Port Proximal Anastomosis System will also be presented.
Collapse
|
14
|
Puskas JD. The Current Status of Anastomotic Devices for Coronary Artery Bypass Surgery. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2009. [DOI: 10.1177/155698450900400103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- John D. Puskas
- Division of Cardiothoracic Surgery, Clinical Research Unit, Emory University School of Medicine, Atlanta, GA
| |
Collapse
|
15
|
Trunfio R, Demertzis S, van den Berg J, Siclari F. A New Surgical Approach for Exclusion of Renal Artery Aneurysms Avoiding Organ Ischemia. Eur J Vasc Endovasc Surg 2008; 36:559-61. [DOI: 10.1016/j.ejvs.2008.06.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2008] [Accepted: 06/14/2008] [Indexed: 11/25/2022]
|
16
|
Kempfert J, Opfermann UT, Richter M, Bossert T, Mohr FW, Gummert JF. Twelve-Month Patency With the PAS-Port Proximal Connector Device: A Single Center Prospective Randomized Trial. Ann Thorac Surg 2008; 85:1579-84. [DOI: 10.1016/j.athoracsur.2008.01.074] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2007] [Revised: 01/18/2008] [Accepted: 01/18/2009] [Indexed: 11/25/2022]
|
17
|
Suyker WJ, Borst C. Coronary Connector Devices: Analysis of 1,469 Anastomoses in 1,216 Patients. Ann Thorac Surg 2008; 85:1828-36. [DOI: 10.1016/j.athoracsur.2008.01.015] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2007] [Revised: 01/03/2008] [Accepted: 01/04/2008] [Indexed: 10/22/2022]
|
18
|
Nishida S, Kikuchi Y, Watanabe G, Shintani Y, Ito S, Tabata S, Kawachi K. How I do it: Traction of Ascending Aorta with Starfish Heart Positioner During Proximal Saphenous Vein Graft Anastomosis Using the PAS-Port System in Off-Pump Coronary Artery Bypass Grafting. Heart Surg Forum 2007; 10:E315-6. [DOI: 10.1532/hsf98.20071072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
19
|
Yasuda T, Watanabe G, Kawachi K. How I Do It: Modified Technique for Vein Preparation Using the SaphLITE Retractor and PAS-Port System. Heart Surg Forum 2007; 10:E141-2. [PMID: 17597039 DOI: 10.1532/hsf98.20061198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
We describe a modified technique of vein preparation using the SaphLITE retractor and PAS-Port aortic connector system in off-pump coronary artery bypass. The combination of these devices can minimize leg wound complication, shorten time to harvest, and enable us to obtain reliable hemostasis.
Collapse
Affiliation(s)
- Tamotsu Yasuda
- Division of Cardiac Surgery, Tokyo Medical University Hospital, Tokyo, Japan.
| | | | | |
Collapse
|
20
|
Wippermann J, Konstas C, Breuer M, Kosmehl H, Wahlers T, Albes JM. Long-term effects in distal coronary anastomoses using different adhesives in a porcine off-pump model. J Thorac Cardiovasc Surg 2006; 132:325-31. [PMID: 16872958 DOI: 10.1016/j.jtcvs.2006.02.042] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2005] [Revised: 01/24/2006] [Accepted: 02/20/2006] [Indexed: 11/28/2022]
Abstract
OBJECTIVE Adhesives are useful supplements to seal distal coronary anastomoses, particularly in patients who receive less-invasive coupling techniques. Information regarding long-term structural effects after application, however, is limited. The purpose of this large animal study was to examine the effects of 3 different commercially available surgical adhesives. METHODS Twelve end-to-side anastomoses were created between the left internal thoracic artery and the left anterior descending coronary artery in a porcine beating heart model. Three different adhesives were applied externally and circumferentially to the anastomosis site. In group I (n = 4) gelatin-resorcinol-formaldehyde glue (Cardial, Technopole, Sainte-Etienne, France), in group II (n = 4) n-butyl-2-cyanoacrylate glue, and in group III (n = 4) albumin-glutaraldehyde glue were used. All anastomoses were examined intraoperatively by flow measurement. After 3 months the anastomoses were reassessed for patency and the vessels were evaluated histologically. RESULTS By means of 4 stay sutures and subsequent glue application, anastomoses could be created successfully on the first attempt in all animals. Perioperative flow through the left internal thoracic artery was similar in all groups. In 4 animals an additional suture was placed to control bleeding. After 3 months, the patency rate was 83.3% (10/12). In group I all anastomoses were patent whereas in both groups II and III one anastomosis was occluded. None of the adhesives caused impaired vessel wall healing but they did demonstrate moderate-to-dense adhesions to the surrounding tissue. On histologic examination, gelantin-resorcinol-formaldehyde glue exhibited minimal tissue reaction (foreign-body granuloma) whereas n-butyl-2-cyanoacrylate glue showed moderate reaction. In contrast, albumin-glutaraldehyde glue caused severe inflammatory reaction with extensive fibroblastic proliferation. CONCLUSION Construction of an end-to-side internal thoracic artery-coronary artery sleeve anastomosis using adhesives was feasible in the pig. Among the tissue adhesives used in this study, gelantin-resorcinol-formaldehyde glue appeared to be superior to cyanoacrylate and albumin-glutaraldehyde glue. The latter one, however, caused severe adverse histologic effects and thus cannot be recommended for bonding coronary anastomoses.
Collapse
Affiliation(s)
- Jens Wippermann
- Department of Cardiothoracic Surgery, University Hospital Cologne, Cologne, Germany.
| | | | | | | | | | | |
Collapse
|