1
|
Shafiei M, Qiu D, Azadani AN. Adaptation of Aortic Bioprosthetic Valves for Pulmonary Position: Comparative Analysis of Transcatheter and Surgical Valves. J Cardiovasc Transl Res 2024; 17:1338-1346. [PMID: 39422840 DOI: 10.1007/s12265-024-10528-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Accepted: 05/21/2024] [Indexed: 10/19/2024]
Abstract
Pulmonary valve dysfunction is common in congenital heart disease, often leading to interventions like right ventricular outflow tract reconstruction. Transcatheter pulmonary valve replacement (TPVR) has emerged as a successful alternative to surgery, showcasing promising outcomes for managing postoperative RVOT complications. The study aimed to compare two bioprosthetic valves-Carpentier Edwards Perimount Magna Ease surgical valve and Edwards SAPIEN 3 transcatheter valve-originally designed for aortic use but adapted for pulmonary applications. The hemodynamic characteristics of a 26-mm SAPIEN 3 and a 25-mm Magna Ease were assessed in a pulse duplicator under both pulmonary and aortic conditions. Furthermore, detailed structural analyses of the leaflets were conducted using computational simulations under these conditions. The results highlighted significant differences in the hydrodynamic and structural characteristics of these two bioprosthetic valves when exposed to pulmonary versus aortic conditions. The study enhances our understanding of the biomechanics involved in surgical and transcatheter pulmonary valve replacement.
Collapse
Affiliation(s)
- Mina Shafiei
- Department of Mechanical and Materials Engineering, University of Denver, 2155 E. Wesley Ave, Room 439, Denver, CO, 80208, USA
| | - Dong Qiu
- Department of Mechanical and Materials Engineering, University of Denver, 2155 E. Wesley Ave, Room 439, Denver, CO, 80208, USA
| | - Ali N Azadani
- Department of Mechanical and Materials Engineering, University of Denver, 2155 E. Wesley Ave, Room 439, Denver, CO, 80208, USA.
| |
Collapse
|
2
|
Brlansky J, Qiu D, Azadani AN. Laser ablation for preventing coronary obstruction and maintaining coronary access in redo-TAVR: A proof of concept. Catheter Cardiovasc Interv 2024; 104:1086-1095. [PMID: 39189066 DOI: 10.1002/ccd.31197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2024] [Revised: 07/02/2024] [Accepted: 08/11/2024] [Indexed: 08/28/2024]
Abstract
BACKGROUND Redo-transcatheter aortic valve replacement (TAVR) is a promising treatment for transcatheter aortic valve degeneration, becoming increasingly relevant with an aging population. In redo-TAVR, the leaflets of the initial (index) transcatheter aortic valve (TAV) are displaced vertically when the second TAV is implanted, creating a cylindrical cage that can impair coronary cannulation and flow. Preventing coronary obstruction and maintaining coronary access is essential, especially in young and low-risk patients undergoing TAVR. This study aimed to develop a new leaflet modification strategy using laser ablation to prevent coronary obstruction and facilitate coronary access after repeat TAVR. METHODS To evaluate the feasibility of the leaflet modification technique using laser ablation, the initial phase of this study involved applying a medical-grade ultraviolet laser for ablation through pericardial tissue. Following this intervention, computational fluid dynamics simulations were utilized to assess the efficacy of the resulting perforations in promoting coronary flow. These simulations played a crucial role in understanding the impact of the modifications on blood flow patterns, ensuring these changes would facilitate the restoration of coronary circulation. RESULTS Laser ablation of pericardium leaflets was successful, demonstrating the feasibility of creating openings in the TAV leaflets. Flow simulation results show that ablation of index valve leaflets can effectively mitigate the flow obstruction caused by sinus sequestration in redo-TAVR, with the extent of restoration dependent on the number and location of the ablated openings. CONCLUSIONS Laser ablation could be a viable method for leaflet modification in redo-TAVR, serving as a new tool in interventional procedures.
Collapse
Affiliation(s)
- John Brlansky
- The DU Cardiovascular Biomechanics Laboratory, Department of Mechanical and Materials Engineering, University of Denver, Denver, Colorado, USA
| | - Dong Qiu
- The DU Cardiovascular Biomechanics Laboratory, Department of Mechanical and Materials Engineering, University of Denver, Denver, Colorado, USA
| | - Ali N Azadani
- The DU Cardiovascular Biomechanics Laboratory, Department of Mechanical and Materials Engineering, University of Denver, Denver, Colorado, USA
| |
Collapse
|
3
|
Magyari B, Kittka B, Goják I, Schönfeld K, Szapáry LB, Simon M, Kiss R, Bertalan A, Várady E, Gyimesi A, Szokodi I, Horváth IG. Single-Center Experience with the Balloon-Expandable Myval Transcatheter Aortic Valve System in Patients with Bicuspid Anatomy: Procedural and 30-Day Follow-Up. J Clin Med 2024; 13:513. [PMID: 38256647 PMCID: PMC10816957 DOI: 10.3390/jcm13020513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2023] [Revised: 01/04/2024] [Accepted: 01/13/2024] [Indexed: 01/24/2024] Open
Abstract
Aims: To report our single-center data regarding the initial 52 consecutive patients with a bicuspid aortic valve who underwent a Transcatheter Aortic Valve Implantation (TAVI) procedure using the new balloon-expandable MYVAL system. The focus is on reporting procedural details and outcomes over the 30-day postoperative period. Methods: From December 2019 to July 2023, 52 consecutive patients underwent a TAVI procedure with bicuspid anatomy. All patients had moderate to-high surgical risk or were unsuitable for surgical aortic valve replacement based on the Heart Team's decision. Outcomes were analyzed according to the VARC-2 criteria. The results of bicuspid patients were compared to patients with tricuspid anatomy in the overall study group, and further analysis involved a comparison between 52 pairs after propensity score matching. The device performance was evaluated using transthoracic echocardiography. Data collection was allowed by the Local Ethical Committee. Results: The mean age was 71 ± 7.1 years, and 65.4% were male. The mean Euroscore II and STS score were 3.3 ± 3.2 and 5.2 ± 3.3, respectively. Baseline characteristics and echocardiographic parameters were well balanced even in the unmatched comparison. Procedures were significantly longer in the bicuspid group and resulted in a significantly higher ARI index. All relevant anatomic dimensions based on the CT scans were significantly higher in bicuspid anatomy, including a higher implantation angulation, a higher rate of horizontal aorta and a higher proportion of patients with aortopathy. In the unmatched bicuspid vs. tricuspid comparison, postprocedural outcomes were as follows: in-hospital mortality 0% vs. 1.4% (p = 0.394), device success 100% vs. 99.1% (p = 0.487), TIA 1.9% vs. 0% (p = 0.041), stroke 1.9% vs. 0.9% (p = 0.537), major vascular complication 3.8% vs. 2.3% (p = 0.530), permanent pacemaker implantation 34% vs. 30.4% (p = 0.429), and cardiac tamponade 0% vs. 0.5% (p = 0.624). In the propensity-matched bicuspid vs. tricuspid comparison, postprocedural outcomes were as follows: in-hospital mortality 0% vs. 0%, device success 100% vs. 100%, TIA 1.9% vs. 0% (p = 0.315), stroke 1.9% vs. 0.9% (p = 0.315), major vascular complication 3.8% vs. 0% (p = 0.475), permanent pacemaker implantation 34% vs. 24% (p = 0.274), and cardiac tamponade 0% vs. 0%. There was no annular rupture nor need for second valve or severe aortic regurgitation in both the unmatched and matched comparison. The peak and mean aortic gradients did not differ at discharge and at 30-day follow-up between the two groups regardless of whether the comparison was unmatched or matched. There were no paravalvular leakages (moderate or above) in the bicuspid patients. Intermediate and extra sizes of the Myval THV system used a significantly higher proportion in bicuspid anatomy with a significantly higher oversize percentage in tricuspid anatomy. Conclusions: The TAVI procedure using the Myval THV system in patients with significant aortic stenosis and bicuspid aortic valve anatomy is safe and effective. Hemodynamic parameters do not differ between tricuspid and bicuspid patients. However, the permanent pacemaker implantation rate is higher than expected; its relevance on long-term survival is controversial.
Collapse
Affiliation(s)
- Balázs Magyari
- Heart Institute, Medical School, University of Pécs, 13 Ifjuság Str., H-7624 Pécs, Hungary; (B.K.); (I.G.); (K.S.); (L.B.S.); (M.S.); (R.K.); (A.B.); (I.S.); (I.G.H.)
- Szentágothai Research Centre, University of Pécs, H-7624 Pécs, Hungary
| | - Bálint Kittka
- Heart Institute, Medical School, University of Pécs, 13 Ifjuság Str., H-7624 Pécs, Hungary; (B.K.); (I.G.); (K.S.); (L.B.S.); (M.S.); (R.K.); (A.B.); (I.S.); (I.G.H.)
- Szentágothai Research Centre, University of Pécs, H-7624 Pécs, Hungary
| | - Ilona Goják
- Heart Institute, Medical School, University of Pécs, 13 Ifjuság Str., H-7624 Pécs, Hungary; (B.K.); (I.G.); (K.S.); (L.B.S.); (M.S.); (R.K.); (A.B.); (I.S.); (I.G.H.)
| | - Kristóf Schönfeld
- Heart Institute, Medical School, University of Pécs, 13 Ifjuság Str., H-7624 Pécs, Hungary; (B.K.); (I.G.); (K.S.); (L.B.S.); (M.S.); (R.K.); (A.B.); (I.S.); (I.G.H.)
- Szentágothai Research Centre, University of Pécs, H-7624 Pécs, Hungary
| | - László Botond Szapáry
- Heart Institute, Medical School, University of Pécs, 13 Ifjuság Str., H-7624 Pécs, Hungary; (B.K.); (I.G.); (K.S.); (L.B.S.); (M.S.); (R.K.); (A.B.); (I.S.); (I.G.H.)
- Szentágothai Research Centre, University of Pécs, H-7624 Pécs, Hungary
| | - Mihály Simon
- Heart Institute, Medical School, University of Pécs, 13 Ifjuság Str., H-7624 Pécs, Hungary; (B.K.); (I.G.); (K.S.); (L.B.S.); (M.S.); (R.K.); (A.B.); (I.S.); (I.G.H.)
- Szentágothai Research Centre, University of Pécs, H-7624 Pécs, Hungary
| | - Rudolf Kiss
- Heart Institute, Medical School, University of Pécs, 13 Ifjuság Str., H-7624 Pécs, Hungary; (B.K.); (I.G.); (K.S.); (L.B.S.); (M.S.); (R.K.); (A.B.); (I.S.); (I.G.H.)
| | - Andrea Bertalan
- Heart Institute, Medical School, University of Pécs, 13 Ifjuság Str., H-7624 Pécs, Hungary; (B.K.); (I.G.); (K.S.); (L.B.S.); (M.S.); (R.K.); (A.B.); (I.S.); (I.G.H.)
| | - Edit Várady
- Department of Medical Imaging, Medical School, University of Pécs, H-7624 Pécs, Hungary;
| | - András Gyimesi
- EconNet Research Group, Faculty of Business and Economics, University of Pécs, H-7624 Pécs, Hungary;
| | - István Szokodi
- Heart Institute, Medical School, University of Pécs, 13 Ifjuság Str., H-7624 Pécs, Hungary; (B.K.); (I.G.); (K.S.); (L.B.S.); (M.S.); (R.K.); (A.B.); (I.S.); (I.G.H.)
- Szentágothai Research Centre, University of Pécs, H-7624 Pécs, Hungary
| | - Iván Gábor Horváth
- Heart Institute, Medical School, University of Pécs, 13 Ifjuság Str., H-7624 Pécs, Hungary; (B.K.); (I.G.); (K.S.); (L.B.S.); (M.S.); (R.K.); (A.B.); (I.S.); (I.G.H.)
- Szentágothai Research Centre, University of Pécs, H-7624 Pécs, Hungary
| |
Collapse
|
4
|
Mylonas KS, Angouras DC. Bioprosthetic Valves for Lifetime Management of Aortic Stenosis: Pearls and Pitfalls. J Clin Med 2023; 12:7063. [PMID: 38002679 PMCID: PMC10672358 DOI: 10.3390/jcm12227063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2023] [Revised: 10/31/2023] [Accepted: 11/02/2023] [Indexed: 11/26/2023] Open
Abstract
This review explores the use of bioprosthetic valves for the lifetime management of patients with aortic stenosis, considering recent advancements in surgical (SAV) and transcatheter bioprostheses (TAV). We examine the strengths and challenges of each approach and their long-term implications. We highlight differences among surgical bioprostheses regarding durability and consider novel surgical valves such as the Inspiris Resilia, Intuity rapid deployment, and Perceval sutureless bioprostheses. The impact of hemodynamics on the performance and durability of these prostheses is discussed, as well as the benefits and considerations of aortic root enlargement during Surgical Aortic Valve Replacement (SAVR). Alternative surgical methods like the Ross procedure and the Ozaki technique are also considered. Addressing bioprosthesis failure, we compare TAV-in-SAV with redo SAVR. Challenges with TAVR, such as TAV explantation and considerations for coronary circulation, are outlined. Finally, we explore the potential challenges and limitations of several clinical strategies, including the TAVR-first approach, in the context of aortic stenosis lifetime management. This concise review provides a snapshot of the current landscape in aortic bioprostheses for physicians and surgeons.
Collapse
Affiliation(s)
| | - Dimitrios C. Angouras
- Department of Cardiac Surgery, Attikon University Hospital, School of Medicine, National and Kapodistrian University of Athens, 15772 Athens, Greece;
| |
Collapse
|
5
|
Barrett A, Brown JA, Smith MA, Woodward A, Vavalle JP, Kheradvar A, Griffith BE, Fogelson AL. A model of fluid-structure and biochemical interactions for applications to subclinical leaflet thrombosis. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3700. [PMID: 37016277 PMCID: PMC10691439 DOI: 10.1002/cnm.3700] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 02/10/2023] [Accepted: 02/20/2023] [Indexed: 05/13/2023]
Abstract
Subclinical leaflet thrombosis (SLT) is a potentially serious complication of aortic valve replacement with a bioprosthetic valve in which blood clots form on the replacement valve. SLT is associated with increased risk of transient ischemic attacks and strokes and can progress to clinical leaflet thrombosis. SLT following aortic valve replacement also may be related to subsequent structural valve deterioration, which can impair the durability of the valve replacement. Because of the difficulty in clinical imaging of SLT, models are needed to determine the mechanisms of SLT and could eventually predict which patients will develop SLT. To this end, we develop methods to simulate leaflet thrombosis that combine fluid-structure interaction and a simplified thrombosis model that allows for deposition along the moving leaflets. Additionally, this model can be adapted to model deposition or absorption along other moving boundaries. We present convergence results and quantify the model's ability to realize changes in valve opening and pressures. These new approaches are an important advancement in our tools for modeling thrombosis because they incorporate both adhesion to the surface of the moving leaflets and feedback to the fluid-structure interaction.
Collapse
Affiliation(s)
- Aaron Barrett
- Department of Mathematics, University of Utah, Salt Lake City, Utah, USA
| | - Jordan A. Brown
- Department of Mathematics, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Margaret Anne Smith
- Department of Mathematics, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Andrew Woodward
- Advanced Medical Imaging Lab, University of North Carolina Medical Center, Chapel Hill, North Carolina, USA
| | - John P. Vavalle
- University of North Carolina School of Medicine, Chapel Hill, North Carolina, USA
- Division of Cardiology, Department of Medicine, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Arash Kheradvar
- Department of Biomedical Engineering, University of California Irvine, Irvine, California, USA
| | - Boyce E. Griffith
- Departments of Mathematics, Applied Physical Sciences, and Biomedical Engineering, University of North Carolina, Chapel Hill, North Carolina, USA
- Carolina Center for Interdisciplinary Applied Mathematics, University of North Carolina, Chapel Hill, North Carolina, USA
- Computational Medicine Program, University of North Carolina, Chapel Hill, North Carolina, USA
- McAllister Heart Institute, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Aaron L. Fogelson
- Departments of Mathematics and Biomedical Engineering, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
6
|
Qiu D, Azadani AN. Structural analysis of regional transcatheter aortic valve underexpansion and its implications for subclinical leaflet thrombosis. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2022; 38:e3641. [PMID: 36054800 DOI: 10.1002/cnm.3641] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 05/31/2022] [Accepted: 08/13/2022] [Indexed: 06/15/2023]
Abstract
Subclinical leaflet thrombosis has been increasingly recognized following transcatheter aortic valve replacement (TAVR). Determining the risk factors is vital in preventing clinical leaflet thrombosis and ensuring long-term value durability. Clinical data have indicated that regional stent under-expansion of transcatheter aortic valves (TAVs), particularly self-expanding devices, may be associated with an increased risk of subclinical leaflet thrombosis. This study aimed to determine the effects of regional TAV frame under-expansion on leaflet kinematics, leaflet structural characteristics, and explore its impact on the likelihood of leaflet thrombosis. In this study, mild and moderate regional frame under-expansion of a 26-mm CoreValve were examined using experimental testing and computational simulations. The results indicated that regional TAV frame under-expansion impairs leaflet kinematics and reduces the range of motion in leaflets with an angle less than 120°. The reduced range of motion can increase blood stasis on the surface of the TAV leaflets. The results also demonstrated that regional frame under-expansion induced localized high-stress regions in the leaflets close to the fixed boundary edge. The increased mechanical stress can lead to accelerated tissue degeneration. The study improves our understanding of the effects of regional stent under-expansion in TAVR. Post-procedural balloon dilatation of self-expanding TAVs can potentially be advantageous in reducing leaflet distortion and normalizing leaflet stress distribution. Large-scale, prospective, and well-controlled studies are needed to further investigate regional TAV frame under-expansion effects on subclinical leaflet thrombosis and long-term valve durability.
Collapse
Affiliation(s)
- Dong Qiu
- The DU Cardiovascular Biomechanics Laboratory, Department of Mechanical and Materials Engineering, University of Denver, Denver, Colorado, USA
| | - Ali N Azadani
- The DU Cardiovascular Biomechanics Laboratory, Department of Mechanical and Materials Engineering, University of Denver, Denver, Colorado, USA
| |
Collapse
|
7
|
Hayashida K. Transcatheter Valve Treatment for a Failed Small Surgical Aortic Valve: Addressing the Achilles' Heel. J Am Coll Cardiol 2022; 80:694-696. [PMID: 35953135 DOI: 10.1016/j.jacc.2022.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 05/27/2022] [Accepted: 06/03/2022] [Indexed: 11/25/2022]
Affiliation(s)
- Kentaro Hayashida
- Department of Cardiology, Keio University School of Medicine, Tokyo, Japan.
| |
Collapse
|
8
|
Batta A, Satish S, Rajan A, Sonawane A, Sihag BK, Barwad P. Strut Inversion During Valve-in-Valve Transcatheter Aortic Valve Replacement: An Unknown Complication? JACC Case Rep 2022; 4:460-463. [PMID: 35493797 PMCID: PMC9044293 DOI: 10.1016/j.jaccas.2021.12.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 12/09/2021] [Accepted: 12/14/2021] [Indexed: 11/25/2022]
Abstract
A 74-year-old man presented with failure of a bioprosthetic aortic valve implanted 7 years earlier, with a mean gradient of 44 mm Hg across the aortic valve. During valve-in-valve transcatheter aortic valve replacement, we came across an unusual complication of strut inversion at the lower end of the valve. (Level of Difficulty: Advanced.).
Collapse
Affiliation(s)
- Akash Batta
- Department of Cardiology, Advanced Cardiac Centre, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Sai Satish
- Department of Cardiology, Apollo Hospital, Chennai, India
| | - Ajay Rajan
- Department of Cardiology, Advanced Cardiac Centre, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Anmol Sonawane
- Department of Cardiology, Breech Candy Hospital, Mumbai, India
| | - Bhupendra Kumar Sihag
- Department of Cardiology, Advanced Cardiac Centre, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Parag Barwad
- Department of Cardiology, Advanced Cardiac Centre, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| |
Collapse
|
9
|
Alperi A, Garcia S, Rodés-Cabau J. Transcatheter valve-in-valve implantation in degenerated surgical aortic and mitral bioprosthesis: Current state and future perspectives. Prog Cardiovasc Dis 2021; 72:54-65. [PMID: 34688669 DOI: 10.1016/j.pcad.2021.10.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Accepted: 10/16/2021] [Indexed: 12/27/2022]
Abstract
The use of bioprosthetic valves for treating patients with severe valve disease has increased over the last 2 decades, and, as a consequence, a growing number of patients with failing surgical bioprosthesis is expected in the near future. In this setting, valve-in-valve (ViV) transcatheter aortic/mitral valve replacement (TAVR and TMVR) has emerged as an alternative to redo surgery. Despite the increasing experience in ViV procedures, the development of these techniques faces several specific challenges, mainly related to the unique anatomical and physiological characteristics presented in ViV-TAVR/TMVR. Subsequently, various approaches have been proposed to overcome ViV-related complications and pitfalls. A growing body of evidence is currently available concerning early- and long-term clinical outcomes of patients undergoing ViV-TAVR/TMVR. These data should be comprehensively evaluated by the Heart Team in the decision-making process involving patients with failing surgical bioprostheses. In this review, we aimed to delineate the technical challenges and risks associated with ViV-TAVR and ViV-TMVR, provide an updated overview of the main clinical results, and summarize the future perspectives of this evolving field.
Collapse
Affiliation(s)
- Alberto Alperi
- Quebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada
| | - Santiago Garcia
- Minneapolis Heart Institute, Minneapolis, MN, United States of America
| | - Josep Rodés-Cabau
- Quebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada.
| |
Collapse
|
10
|
Ciardetti N, Ciatti F, Nardi G, Di Muro FM, Demola P, Sottili E, Stolcova M, Ristalli F, Mattesini A, Meucci F, Di Mario C. Advancements in Transcatheter Aortic Valve Implantation: A Focused Update. MEDICINA (KAUNAS, LITHUANIA) 2021; 57:711. [PMID: 34356992 PMCID: PMC8306774 DOI: 10.3390/medicina57070711] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 07/09/2021] [Accepted: 07/12/2021] [Indexed: 01/07/2023]
Abstract
Transcatheter aortic valve implantation (TAVI) has become the leading technique for aortic valve replacement in symptomatic patients with severe aortic stenosis with conventional surgical aortic valve replacement (SAVR) now limited to patients younger than 65-75 years due to a combination of unsuitable anatomies (calcified raphae in bicuspid valves, coexistent aneurysm of the ascending aorta) and concerns on the absence of long-term data on TAVI durability. This incredible rise is linked to technological evolutions combined with increased operator experience, which led to procedural refinements and, accordingly, to better outcomes. The article describes the main and newest technical improvements, allowing an extension of the indications (valve-in-valve procedures, intravascular lithotripsy for severely calcified iliac vessels), and a reduction of complications (stroke, pacemaker implantation, aortic regurgitation).
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | - Carlo Di Mario
- Structural Interventional Cardiology, Department of Clinical and Experimental Medicine, Clinica Medica, Room 124, Careggi University Hospital, Largo Brambilla 3, 50139 Florence, Italy; (N.C.); (F.C.); (G.N.); (F.M.D.M.); (P.D.); (E.S.); (M.S.); (F.R.); (A.M.); (F.M.)
| |
Collapse
|
11
|
Qiu D, Barakat M, Hopkins B, Ravaghi S, Azadani AN. Transcatheter aortic valve replacement in bicuspid valves: The synergistic effects of eccentric and incomplete stent deployment. J Mech Behav Biomed Mater 2021; 121:104621. [PMID: 34130079 DOI: 10.1016/j.jmbbm.2021.104621] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 04/19/2021] [Accepted: 05/28/2021] [Indexed: 10/21/2022]
Abstract
Bicuspid aortic valve is a congenital cardiac anomaly and common etiology of aortic stenosis. Given the positive outcomes of transcatheter aortic valve replacement (TAVR) in low-risk patients, TAVR will become more prevalent in the future in the treatment of severe bicuspid valve stenosis. However, asymmetrical bicuspid valve anatomy and calcification can prevent the circular and complete expansion of transcatheter aortic valves (TAVs). In previous studies, examining the impact of elliptical TAV deployment on leaflet stress distribution, asymmetric expansion of balloon-expandable intra-annular devices was studied up to an ellipticity index (long/short TAV diameter) of 1.4. However, such a high degree of eccentricity has not been observed in clinical studies with balloon-expandable devices. High degrees of stent eccentricity have been observed in self-expanding TAVs, such as CoreValve. However, CoreValve is a supra-annular device, and it was not clear if eccentric and incomplete stent deployment at the annulus would alter leaflet stress and strain distributions. This study aimed to assess the effects of eccentric and incomplete stent deployment of CoreValves in bicuspid aortic valves and compare the results to that of SAPIEN 3. Leaflet stress distribution and leaflet kinematics of 26-mm CoreValve and 26-mm SAPIEN 3 devices in bicuspid valves were obtained in a range that was observed in previous clinical studies. The results indicated that elliptical and incomplete stent deployment of TAVs increase leaflet stress and impair leaflet kinematics. The changes were more pronounced in CoreValve than SAPIEN 3. Increased leaflet stress can reduce long-term valve durability, and impaired leaflet kinematics can potentially increase blood stasis on the TAV leaflets. The study provides complementary insights into the mechanics of TAVs in bicuspid aortic valves.
Collapse
Affiliation(s)
- Dong Qiu
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA
| | - Mohammed Barakat
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA
| | - Brenna Hopkins
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA
| | - Saba Ravaghi
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA
| | - Ali N Azadani
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA.
| |
Collapse
|
12
|
Ng ACT, Holmes DR, Mack MJ, Delgado V, Makkar R, Blanke P, Leipsic JA, Leon MB, Bax JJ. Leaflet immobility and thrombosis in transcatheter aortic valve replacement. Eur Heart J 2021; 41:3184-3197. [PMID: 32930773 PMCID: PMC9186299 DOI: 10.1093/eurheartj/ehaa542] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 04/17/2020] [Accepted: 07/01/2020] [Indexed: 12/13/2022] Open
Abstract
Transcatheter aortic valve replacement (TAVR) has grown exponentially worldwide in the last decade. Due to the higher bleeding risks associated with oral anticoagulation and in patients undergoing TAVR, antiplatelet therapy is currently considered first-line antithrombotic treatment after TAVR. Recent studies suggest that some patients can develop subclinical transcatheter heart valve (THV) thrombosis after the procedure, whereby thrombus forms on the leaflets that can be a precursor to leaflet dysfunction. Compared with echocardiography, multidetector computed tomography is more sensitive at detecting THV thrombosis. Transcatheter heart valve thrombosis can occur while on dual antiplatelet therapy with aspirin and thienopyridine but significantly less with anticoagulation. This review summarizes the incidence and diagnostic criteria for THV thrombosis and discusses the pathophysiological mechanisms that may lead to thrombus formation, its natural history, potential clinical implications and treatment for these patients. ![]()
Collapse
Affiliation(s)
- Arnold C T Ng
- Department of Cardiology, Princess Alexandra Hospital, Brisbane, Australia
| | - David R Holmes
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | | | - Victoria Delgado
- Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, The Netherlands
| | - Raj Makkar
- Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Philipp Blanke
- Department of Radiology, St. Paul's Hospital and University of British Columbia, Vancouver, British Columbia, Canada
| | - Jonathon A Leipsic
- Department of Radiology, St. Paul's Hospital and University of British Columbia, Vancouver, British Columbia, Canada
| | - Martin B Leon
- Columbia University Medical Center, New York-Presbyterian Hospital, New York, NY, USA
| | - Jeroen J Bax
- Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, The Netherlands
| |
Collapse
|
13
|
Saad M, Seoudy H, Frank D. Challenging Anatomies for TAVR-Bicuspid and Beyond. Front Cardiovasc Med 2021; 8:654554. [PMID: 33928138 PMCID: PMC8076502 DOI: 10.3389/fcvm.2021.654554] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2021] [Accepted: 03/15/2021] [Indexed: 12/23/2022] Open
Abstract
Transcatheter aortic valve replacement has emerged as the standard treatment for the majority of patients with symptomatic aortic stenosis. As transcatheter aortic valve replacement expands to patients across all risk groups, optimal patient selection strategies and device implantation techniques become increasingly important. A significant number of patients referred for transcatheter aortic valve replacement present with challenging anatomies and clinical indications that had been historically considered a contraindication for transcatheter aortic valve replacement. This article aims to highlight and discuss some of the potential obstacles that are encountered in clinical practice with a particular emphasis on bicuspid aortic valve disease.
Collapse
Affiliation(s)
- Mohammed Saad
- Department of Internal Medicine III, Cardiology and Angiology, University Hospital Schleswig-Holstein, Kiel, Germany
| | - Hatim Seoudy
- Department of Internal Medicine III, Cardiology and Angiology, University Hospital Schleswig-Holstein, Kiel, Germany.,DZHK (German Centre for Cardiovascular Research), Partner Site Hamburg/Kiel/Lübeck, Kiel, Germany
| | - Derk Frank
- Department of Internal Medicine III, Cardiology and Angiology, University Hospital Schleswig-Holstein, Kiel, Germany.,DZHK (German Centre for Cardiovascular Research), Partner Site Hamburg/Kiel/Lübeck, Kiel, Germany
| |
Collapse
|
14
|
Plitman Mayo R, Yaakobovich H, Finkelstein A, Shadden SC, Marom G. Impact of BASILICA on the thrombogenicity potential of valve-in-valve implantations. J Biomech 2021; 118:110309. [PMID: 33601181 DOI: 10.1016/j.jbiomech.2021.110309] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 02/03/2021] [Indexed: 01/17/2023]
Abstract
Subclinical leaflet thrombosis is becoming a major concern in valve-in-valve procedures, whereby a transcatheter aortic valve device is deployed inside a failed bioprosthetic surgical valve. Blood flow stagnation and prolonged residence times in the neo-sinuses have been suggested as possible explanations for leaflet thrombosis. The BASILICA technique, which was originally developed to treat coronary flow obstruction, has also been proposed as an alternative to reduce the risk of thrombus formation. The aim of this study is to understand the impact of BASILICA on the valve-in-valve thrombogenicity using computational fluid dynamics simulations. To this end, two Eulerian and two Lagrangian approaches were employed to estimate near-wall stagnation measures in eight valve-in-valve models. The models included an intact or lacerated Sorin Mitroflow surgical valve, and either a SAPIEN or Evolut transcatheter aortic valve device. The Lagrangian approaches predicted a high number of particles and vortices concentration in the proximal areas of the neo-sinuses, while the Eulerian approaches did so in the distal areas. As a consequence, this study demonstrated that Lagrangian approaches are better predictors of subclinical leaflet thrombosis, since they match experimental and clinical findings. Additionally, the SAPIEN valve possess a higher risk for developing leaflet thrombosis, and two lacerations are shown to provide the best results in terms of development of vortices and accumulation of particles within the neo-sinuses. This study highlights the potential of computational modeling in aiding clinicians in their decision-making in valve-in-valve and BASILICA procedures.
Collapse
Affiliation(s)
| | - Halit Yaakobovich
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel
| | | | - Shawn C Shadden
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA
| | - Gil Marom
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel.
| |
Collapse
|
15
|
Plitman Mayo R, Yaakobovich H, Finkelstein A, Shadden SC, Marom G. Numerical models for assessing the risk of leaflet thrombosis post-transcatheter aortic valve-in-valve implantation. ROYAL SOCIETY OPEN SCIENCE 2020; 7:201838. [PMID: 33489295 PMCID: PMC7813235 DOI: 10.1098/rsos.201838] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Accepted: 11/20/2020] [Indexed: 05/04/2023]
Abstract
Leaflet thrombosis has been suggested as the reason for the reduced leaflet motion in cases of hypoattenuated leaflet thickening of bioprosthetic aortic valves. This work aimed to estimate the risk of leaflet thrombosis in two post-valve-in-valve (ViV) configurations, using five different numerical approaches. Realistic ViV configurations were calculated by modelling the deployments of the latest version of transcatheter aortic valve devices (Medtronic Evolut PRO, Edwards SAPIEN 3) in the surgical Sorin Mitroflow. Computational fluid dynamics simulations of blood flow followed the dry models. Lagrangian and Eulerian measures of near-wall stagnation were implemented by particle and concentration tracking, respectively, to estimate the thrombogenicity and to predict the risk locations. Most of the numerical approaches indicate a higher leaflet thrombosis risk in the Edwards SAPIEN 3 device because of its intra-annular implantation. The Eulerian approaches estimated high-risk locations in agreement with the wall sheer stress (WSS) separation points. On the other hand, the Lagrangian approaches predicted high-risk locations at the proximal regions of the leaflets matching the low WSS magnitude regions of both transcatheter aortic valve implantation models and reported clinical and experimental data. The proposed methods can help optimizing future designs of transcatheter aortic valves with minimal thrombotic risks.
Collapse
Affiliation(s)
- Romina Plitman Mayo
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel
- Department of Biological Regulation, Weizmann Institute of Science, Herzl Street 234, Rehovot, Israel
| | - Halit Yaakobovich
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel
| | | | - Shawn C. Shadden
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA
| | - Gil Marom
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
16
|
Predictors and Biomarkers of Subclinical Leaflet Thrombosis after Transcatheter Aortic Valve Implantation. J Clin Med 2020; 9:jcm9113742. [PMID: 33233321 PMCID: PMC7700436 DOI: 10.3390/jcm9113742] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 11/12/2020] [Accepted: 11/18/2020] [Indexed: 01/03/2023] Open
Abstract
Transcatheter aortic valve implantation (TAVI) is a recent revolutionary treatment for high-risk patients with severe aortic stenosis who are not suitable for surgery, expanding to intermediate and low-risk patients. Valve leaflet thrombosis (LT) is a potentially fatal complication after TAVI. The incidence of subclinical LT is as high as 25% among patients in the first year after TAVI. Subclinical LT may evolve into symptomatic thrombosis or lead to premature bioprosthesis degeneration, increasing the risk of neurological complications. Because imaging-based methods have limited sensitivity to detect subclinical LT, there is an urgent need for predictors and biomarkers that would make it possible to predict LT after TAVI. Here, we summarize recent data regarding (i) patient-related, (ii) procedure-related, (iii) blood-based and (iv) imaging predictors and biomarkers which might be useful for the early diagnosis of subclinical LT after TAVI. Prevention of LT might offer an opportunity to improve risk stratification and tailor therapy after TAVI.
Collapse
|
17
|
Simonato M, Dvir D. The Ten Commandments of Aortic Valve-in-Valve. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2020; 15:397-405. [PMID: 32955362 DOI: 10.1177/1556984520951874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- Matheus Simonato
- 28105 Escola Paulista de Medicina Universidade Federal de São Paulo, Brazil
| | - Danny Dvir
- 26743 Jesselson Integrated Heart Centre, ShaareZedek Medical Center, Hebrew University, Jerusalem, Israel.,Division of Cardiology, University of Washington, Seattle, WA, USA
| |
Collapse
|
18
|
Valve-in-Valve Transcatheter Aortic Valve Replacement: A Review of Procedural Details, Safety, and Clinical Implications. Cardiol Rev 2020; 28:291-294. [DOI: 10.1097/crd.0000000000000318] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
19
|
Nappi F, Nenna A, Sing SSA, Timofeeva I, Mihos C, Gentile F, Chello M. Are the dynamic changes of the aortic root determinant for thrombosis or leaflet degeneration after transcatheter aortic valve replacement? J Thorac Dis 2020; 12:2919-2925. [PMID: 32642204 PMCID: PMC7330384 DOI: 10.21037/jtd.2020.02.01] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Accepted: 01/16/2020] [Indexed: 11/19/2022]
Abstract
The role of the aortic root is to convert the accumulated elastic energy during systole into kinetic flow energy during diastole, in order to improve blood distribution in the coronary tree. Therefore, the sinuses of Valsalva of the aortic root are not predisposed to accept any bulky material, especially in case of uncrushed solid calcific agglomerates. This concept underlines the differences between surgical aortic valve replacement, in which decalcification is a main part of the procedure, and transcatheter aortic valve replacement (TAVR). Cyclic changes in shape and size of the aortic root influence blood flow in the Valsalva sinuses. Recent papers have been investigating the dynamic changes of the aortic root and whether those differences might be correlated with clinical effects, and this paper aims to summarize part of this flourishing literature. Post-TAVR aortic root remodeling, dynamic flow and TAVR complications might have a fluidodynamic background, and clinically observed side effects such as thrombosis or leaflet degeneration should be further investigated in basic researches. Also, aortic root changes could impact valve type and size selection, affecting the decision of over-sizing or under-sizing in order to prevent valve embolization or coronary ostia obstruction.
Collapse
Affiliation(s)
- Francesco Nappi
- Department of Cardiac Surgery, Centre Cardiologique du Nord de Saint-Denis, Paris, France
| | - Antonio Nenna
- Department of Cardiovascular Surgery, Università Campus Bio-Medico di Roma, Rome, Italy
| | - Sanjeet Singh Avvtar Sing
- Department of Cardiac Surgery, Golden Jubilee National Hospital, Glasgow, UK
- Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, UK
| | - Irina Timofeeva
- Department of Imaging, Centre Cardiologique du Nord de Saint-Denis, Paris, France
| | - Christos Mihos
- Echocardiography Lab, Columbia University Division of Cardiology, Mount Sinai Heart Institute, Miami, USA
| | | | - Massimo Chello
- Department of Cardiovascular Surgery, Università Campus Bio-Medico di Roma, Rome, Italy
| |
Collapse
|
20
|
Abstract
Heart valve diseases are common disorders with five million annual diagnoses being made in the United States alone. All heart valve disorders alter cardiac hemodynamic performance; therefore, treatments aim to restore normal flow. This paper reviews the state-of-the-art clinical and engineering advancements in heart valve treatments with a focus on hemodynamics. We review engineering studies and clinical literature on the experience with devices for aortic valve treatment, as well as the latest advancements in mitral valve treatments and the pulmonic and tricuspid valves on the right side of the heart. Upcoming innovations will potentially revolutionize treatment of heart valve disorders. These advancements, and more gradual enhancements in the procedural techniques and imaging modalities, could improve the quality of life of patients suffering from valvular disease who currently cannot be treated.
Collapse
Affiliation(s)
- Gil Marom
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv Israel
- To whom correspondence should be addressed. E-mail:
| | - Shmuel Einav
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
21
|
Khodaee F, Barakat M, Abbasi M, Dvir D, Azadani AN. Incomplete expansion of transcatheter aortic valves is associated with propensity for valve thrombosis. Interact Cardiovasc Thorac Surg 2019; 30:39-46. [DOI: 10.1093/icvts/ivz213] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Revised: 06/24/2019] [Accepted: 08/04/2019] [Indexed: 11/14/2022] Open
Abstract
Abstract
OBJECTIVES
Clinical and subclinical leaflet thromboses are increasingly recognized complications following transcatheter aortic valve replacement. Identification of the risk factors is important to mitigate the occurrence of leaflet thrombosis in transcatheter aortic valves (TAVs) and ensure their long-term function. The goal of this study was to determine the effect of incomplete expansion of TAVs on the likelihood of leaflet thrombosis following transcatheter aortic valve replacement.
METHODS
Using experimental and computational methods, 3-dimensional unsteady flow fields of 26-mm SAPIEN 3 valves expanded to 3 different diameters (i.e. 26.0 mm, 23.4 mm and 20.8 mm) were determined in patient-specific geometries. The diameters corresponded to 100%, 90% and 80% stent expansion, respectively. To address the potential difference in the likelihood of leaflet thrombosis, blood residence time (i.e. stasis) and viscous shear stress on the surface of TAV leaflets were quantified and compared.
RESULTS
The results indicated that TAV underexpansion increased blood stasis on the TAV leaflets. Blood residence time on the surface of the leaflets after 80% and 90% TAV expansion on average was 9.4% and 4.1% more than that of the fully expanded TAV, respectively. In addition, areas of blood stasis time of more than 0.5 s, which are highly prone to platelet activation, increased linearly as the degree of TAV underexpansion increased.
CONCLUSIONS
Incomplete expansion of TAVs increases blood stasis on the surface of TAV leaflets. Regions of blood stasis promote platelet activation and thrombotic events. TAV underexpansion can therefore increase the risk of leaflet thrombosis in patients with transcatheter aortic valve replacement.
Collapse
Affiliation(s)
- Farhan Khodaee
- The DU Cardiovascular Biomechanics Laboratory, Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA
| | - Mohammed Barakat
- The DU Cardiovascular Biomechanics Laboratory, Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA
| | - Mostafa Abbasi
- The DU Cardiovascular Biomechanics Laboratory, Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA
| | - Danny Dvir
- Division of Cardiology, Department of Medicine, University of Washington, Seattle, WA, USA
| | - Ali N Azadani
- The DU Cardiovascular Biomechanics Laboratory, Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA
| |
Collapse
|
22
|
Luraghi G, Migliavacca F, García-González A, Chiastra C, Rossi A, Cao D, Stefanini G, Rodriguez Matas JF. On the Modeling of Patient-Specific Transcatheter Aortic Valve Replacement: A Fluid-Structure Interaction Approach. Cardiovasc Eng Technol 2019; 10:437-455. [PMID: 31309527 DOI: 10.1007/s13239-019-00427-0] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Accepted: 07/04/2019] [Indexed: 12/14/2022]
Abstract
PURPOSE Transcatheter aortic valve replacement (TAVR) is a minimally invasive treatment for high-risk patients with aortic diseases. Despite its increasing use, many influential factors are still to be understood and require continuous investigation. The best numerical approach capable of reproducing both the valves mechanics and the hemodynamics is the fluid-structure interaction (FSI) modeling. The aim of this work is the development of a patient-specific FSI methodology able to model the implantation phase as well as the valve working conditions during cardiac cycles. METHODS The patient-specific domain, which included the aortic root, native valve and calcifications, was reconstructed from CT images, while the CAD model of the device, metallic frame and pericardium, was drawn from literature data. Ventricular and aortic pressure waveforms, derived from the patient's data, were used as boundary conditions. The proposed method was applied to two real clinical cases, which presented different outcomes in terms of paravalvular leakage (PVL), the main complication after TAVR. RESULTS The results confirmed the clinical prognosis of mild and moderate PVL with coherent values of regurgitant volume and effective regurgitant orifice area. Moreover, the final release configuration of the device and the velocity field were compared with postoperative CT scans and Doppler traces showing a good qualitative and quantitative matching. CONCLUSION In conclusion, the development of realistic and accurate FSI patient-specific models can be used as a support for clinical decisions before the implantation.
Collapse
Affiliation(s)
- Giulia Luraghi
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Piazza L. da Vinci 32, 20133, Milan, Italy.
| | - Francesco Migliavacca
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Piazza L. da Vinci 32, 20133, Milan, Italy
| | - Alberto García-González
- Laboratori de Càlcul Numèric (LaCàN), E.T.S. de Ingenieros de Caminos, Canales y Puertos, Universitat Politècnica de Catalunya (UPC), Jordi Girona 1-3, 08034, Barcelona, Spain
| | - Claudio Chiastra
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Piazza L. da Vinci 32, 20133, Milan, Italy.,PoliToBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129, Turin, Italy
| | - Alexia Rossi
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Pieve Emanuele, MI, Italy
| | - Davide Cao
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Pieve Emanuele, MI, Italy
| | - Giulio Stefanini
- Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Pieve Emanuele, MI, Italy
| | - Jose Felix Rodriguez Matas
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Piazza L. da Vinci 32, 20133, Milan, Italy
| |
Collapse
|
23
|
Khodaee F, Qiu D, Dvir D, Azadani AN. Reducing the risk of leaflet thrombosis in transcatheter aortic valve-in-valve implantation by BASILICA: a computational simulation study. EUROINTERVENTION 2019; 15:67-70. [PMID: 30888960 DOI: 10.4244/eij-d-19-00048] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Farhan Khodaee
- The DU Cardiovascular Biomechanics Laboratory, Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA
| | | | | | | |
Collapse
|
24
|
Edelman JJ, Khan JM, Rogers T, Shults C, Satler LF, Ben-Dor II, Waksman R, Thourani VH. Valve-in-Valve TAVR: State-of-the-Art Review. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2019; 14:299-310. [DOI: 10.1177/1556984519858020] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
An increasing number of surgically implanted bioprostheses will require re-intervention for structural valve deterioration. Valve-in-valve transcatheter aortic valve replacement (ViV TAVR) has become an alternative to reoperative surgery, currently approved for high-risk and inoperable patients. Challenges to the technique include higher rates of prosthesis–patient mismatch and coronary obstruction, compared to native valve TAVR. Herein, we review results of ViV TAVR and novel techniques to overcome the aforementioned challenges.
Collapse
Affiliation(s)
- J. James Edelman
- Department of Cardiac Surgery, MedStar Heart and Vascular Institute, Georgetown University School of Medicine, Washington, DC, USA
| | - Jaffar M. Khan
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Toby Rogers
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Christian Shults
- Department of Cardiac Surgery, MedStar Heart and Vascular Institute, Georgetown University School of Medicine, Washington, DC, USA
| | - Lowell F. Satler
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA
| | - I. Itsik Ben-Dor
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA
| | - Ron Waksman
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA
| | - Vinod H. Thourani
- Department of Cardiac Surgery, MedStar Heart and Vascular Institute, Georgetown University School of Medicine, Washington, DC, USA
| |
Collapse
|
25
|
Windecker S, Khan F, Pilgrim T. TAVR for the Treatment of Degenerated Aortic Bioprostheses: Aiming at a Moving Target. J Am Coll Cardiol 2019; 73:2656-2659. [PMID: 31146809 DOI: 10.1016/j.jacc.2019.02.070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Accepted: 02/18/2019] [Indexed: 10/26/2022]
Affiliation(s)
- Stephan Windecker
- Department of Cardiology, Inselspital, University of Bern, Bern, Switzerland.
| | - Faisal Khan
- Department of Cardiology, Inselspital, University of Bern, Bern, Switzerland
| | - Thomas Pilgrim
- Department of Cardiology, Inselspital, University of Bern, Bern, Switzerland
| |
Collapse
|
26
|
Abdel-Wahab M, Simonato M, Latib A, Goleski PJ, Allali A, Kaur J, Azadani AN, Horlick E, Testa L, Orvin K, Kornowski R, Kass M, Don CW, Richardt G, Webb JG, Dvir D. Clinical Valve Thrombosis After Transcatheter Aortic Valve-in-Valve Implantation. Circ Cardiovasc Interv 2018; 11:e006730. [DOI: 10.1161/circinterventions.118.006730] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Affiliation(s)
- Mohamed Abdel-Wahab
- Department of Cardiology, Heart Center, Segeberger Kliniken, Bad Segeberg, Germany (M.A.-W., A.A., J.K., G.R.)
- Department of Cardiology, Heart Center Leipzig–University Hospital, Germany (M.A.-W.)
| | - Matheus Simonato
- Centre for Heart Valve Innovation, Department of Cardiology, St. Paul’s Hospital, Vancouver, Canada (M.S., J.G.W., D.D.)
| | - Azeem Latib
- Cardiologia Interventistica ed Emodinamica, Ospedale San Raffaele, Milan, Italy (A.L.)
| | - Patrick J. Goleski
- Division of Cardiology, University of Washington, Seattle (P.J.G., C.W.D., D.D.)
| | - Abdelhakim Allali
- Department of Cardiology, Heart Center, Segeberger Kliniken, Bad Segeberg, Germany (M.A.-W., A.A., J.K., G.R.)
| | - Jatinderjit Kaur
- Department of Cardiology, Heart Center, Segeberger Kliniken, Bad Segeberg, Germany (M.A.-W., A.A., J.K., G.R.)
| | - Ali N. Azadani
- Department of Mechanical and Materials Engineering, University of Denver, CO (A.N.A.)
| | - Eric Horlick
- Peter Munk Cardiac Centre, University Health Network, University of Toronto, Canada (E.H.)
| | - Luca Testa
- Department of Cardiology, IRCCS Pol. S. Donato, Milan, Italy (L.T.)
| | - Katia Orvin
- Department of Cardiology, Rabin Medical Center, Petach Tikva, Israel (K.O., R.K.)
| | - Ran Kornowski
- Department of Cardiology, Rabin Medical Center, Petach Tikva, Israel (K.O., R.K.)
| | - Malek Kass
- Section of Cardiology, Saint Boniface Hospital, University of Manitoba, Winnipeg, Canada (M.K.)
| | - Creighton W. Don
- Division of Cardiology, University of Washington, Seattle (P.J.G., C.W.D., D.D.)
| | - Gert Richardt
- Department of Cardiology, Heart Center, Segeberger Kliniken, Bad Segeberg, Germany (M.A.-W., A.A., J.K., G.R.)
| | - John G. Webb
- Centre for Heart Valve Innovation, Department of Cardiology, St. Paul’s Hospital, Vancouver, Canada (M.S., J.G.W., D.D.)
| | - Danny Dvir
- Centre for Heart Valve Innovation, Department of Cardiology, St. Paul’s Hospital, Vancouver, Canada (M.S., J.G.W., D.D.)
- Division of Cardiology, University of Washington, Seattle (P.J.G., C.W.D., D.D.)
| |
Collapse
|
27
|
Rotman OM, Bianchi M, Ghosh RP, Kovarovic B, Bluestein D. Principles of TAVR valve design, modelling, and testing. Expert Rev Med Devices 2018; 15:771-791. [PMID: 30318937 PMCID: PMC6417919 DOI: 10.1080/17434440.2018.1536427] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
INTRODUCTION Transcatheter aortic valve replacement (TAVR) has emerged as an effective minimally-invasive alternative to surgical valve replacement in medium- to high-risk, elderly patients with calcific aortic valve disease and severe aortic stenosis. The rapid growth of the TAVR devices market has led to a high variety of designs, each aiming to address persistent complications associated with TAVR valves that may hamper the anticipated expansion of TAVR utility. AREAS COVERED Here we outline the challenges and the technical demands that TAVR devices need to address for achieving the desired expansion, and review design aspects of selected, latest generation, TAVR valves of both clinically-used and investigational devices. We further review in detail some of the up-to-date modeling and testing approaches for TAVR, both computationally and experimentally, and additionally discuss those as complementary approaches to the ISO 5840-3 standard. A comprehensive survey of the prior and up-to-date literature was conducted to cover the most pertaining issues and challenges that TAVR technology faces. EXPERT COMMENTARY The expansion of TAVR over SAVR and to new indications seems more promising than ever. With new challenges to come, new TAV design approaches, and materials used, are expected to emerge, and novel testing/modeling methods to be developed.
Collapse
Affiliation(s)
- Oren M. Rotman
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| | - Matteo Bianchi
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| | - Ram P. Ghosh
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| | - Brandon Kovarovic
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| |
Collapse
|
28
|
Barakat M, Dvir D, Azadani AN. Fluid Dynamic Characterization of Transcatheter Aortic Valves Using Particle Image Velocimetry. Artif Organs 2018; 42:E357-E368. [DOI: 10.1111/aor.13290] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2017] [Revised: 03/27/2018] [Accepted: 05/01/2018] [Indexed: 01/01/2023]
Affiliation(s)
- Mohammed Barakat
- Department of Mechanical and Materials Engineering; University of Denver; Denver CO USA
| | - Danny Dvir
- Department of Medicine, Division of Cardiology; University of Washington; Seattle WA USA
| | - Ali N. Azadani
- Department of Mechanical and Materials Engineering; University of Denver; Denver CO USA
| |
Collapse
|
29
|
Kandail HS, Trivedi SD, Shaikh AC, Bajwa TK, O'Hair DP, Jahangir A, LaDisa JF. Impact of annular and supra-annular CoreValve deployment locations on aortic and coronary artery hemodynamics. J Mech Behav Biomed Mater 2018; 86:131-142. [PMID: 29986288 DOI: 10.1016/j.jmbbm.2018.06.032] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Revised: 06/04/2018] [Accepted: 06/21/2018] [Indexed: 01/12/2023]
Abstract
CoreValve is widely used in transcatheter aortic valve replacement, but the impact of its deployment location on hemodynamics is unexplored despite a potential role in subsequent aortic and coronary artery pathologies. The objectives of this investigation were to perform fluid-structure interaction (FSI) simulations for a 29 mm CoreValve deployed in annular vs supra-annular locations, and characterize resulting hemodynamics including velocity and wall shear stress (WSS). Patient-specific geometry was reconstructed from computed tomography scans and CoreValve was deployed using a finite element approach. FSI simulations were then performed using a boundary conforming method and realistic boundary conditions. Results showed that CoreValve deployment location impacts hemodynamics in the ascending aorta and flow patterns in the coronary arteries. During peak-systole, annularly deployed CoreValve produced a jet-like flow structure impinging on the outer-curvature of the ascending aorta. Supra-annularly deployed CoreValve having a lateral tilt of 10° led to a more centered jet impinging further downstream. At mid-systole, valve leaflets of the annularly deployed CoreValve closed asymmetrically leading to disorganized flow patterns in the ascending aorta vs those from the supra-annular position. Supra-annularly deployed CoreValve also led to high-velocity para-valvular flow supplying the coronary arteries. CoreValve in the supra-annular position significantly (P < 0.05) elevated WSS within the first few diameters of both coronary arteries as compared to the annular position for many time points quantified. These results afforded by the advanced simulation methods may have important clinical implications given the role of aortic hemodynamics in dilation and the pro-atherogenic nature of WSS alterations in the coronary arteries.
Collapse
Affiliation(s)
- Harkamaljot S Kandail
- Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, WI, USA.
| | - Setu D Trivedi
- Aurora Cardiovascular Services, Aurora St. Luke's Medical Center, Milwaukee, WI, USA
| | - Armaan C Shaikh
- Aurora Cardiovascular Services, Aurora St. Luke's Medical Center, Milwaukee, WI, USA
| | - Tanvir K Bajwa
- Aurora Cardiovascular Services, Aurora St. Luke's Medical Center, Milwaukee, WI, USA
| | - Daniel P O'Hair
- Aurora Cardiovascular Services, Aurora St. Luke's Medical Center, Milwaukee, WI, USA
| | - Arshad Jahangir
- Aurora Cardiovascular Services, Aurora St. Luke's Medical Center, Milwaukee, WI, USA
| | - John F LaDisa
- Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, WI, USA; Department of Medicine, Division of Cardiovascular Medicine, Medical College of Wisconsin, Milwaukee, WI, USA
| |
Collapse
|
30
|
Abstract
Transcatheter aortic valve implantation (TAVI) has emerged as a viable treatment modality for patients with severe aortic valve stenosis and multiple co-morbidities. More recent indications include the use of transcatheter heart valves (THV) to treat degenerated bioprosthetic surgical heart valves (SHV), which are failing due to stenosis or regurgitation. Valve-in-valve (VIV) procedures in the aortic position have been performed with a variety of THV devices, although the balloon-expandable SAPIEN valve platform (Edwards Lifesciences Ltd, Irvine, CA, USA) and self-expandable CoreValve platform (Medtronic Inc., MN, USA) have been used in majority of the patients. VIV treatment is appealing as it is less invasive than conventional surgery but optimal patient selection is vital to avoid complications such as malposition, residual high gradients and coronary obstruction. To minimize the risk of complications, thorough procedural planning is critical. The first step is identification of the degenerated SHV, including its model, size, fluoroscopic appearance. Although label size and stent internal diameter (ID) are provided by the manufacturer, it is important to note the true ID. The true ID is the ID of a SHV after the leaflets are mounted and helps determine the optimal size of THV. The second step is to determine the type and size of the THV. Although this is determined in the majority of the cases by user preference, in certain situations one THV may be more suitable than another. As the procedure is performed under fluoroscopy, the third step is to become familiarized with the fluoroscopic appearance of both the SHV and THV. This helps to determine the landmarks for optimal positioning, which in turn determines the gradients and fixation. The fourth step is to assess the risk of coronary obstruction. This is performed with either aortic root angiography or ECG-gated computerised tomography (CT). Finally, the route of approach must be carefully planned. Once these aspects are addressed, the procedure can be performed efficiently with a low risk of complications.
Collapse
Affiliation(s)
- Vinayak Bapat
- Cardiovascular Division, New York Presbyterian Hospital, Columbia University Medical Centre, New York, NY, USA
| |
Collapse
|
31
|
Vahidkhah K, Azadani AN. Supra-annular Valve-in-Valve implantation reduces blood stasis on the transcatheter aortic valve leaflets. J Biomech 2017; 58:114-122. [DOI: 10.1016/j.jbiomech.2017.04.020] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2016] [Revised: 03/08/2017] [Accepted: 04/24/2017] [Indexed: 01/08/2023]
|