Lauro E, Corridori I, Luciani L, Di Leo A, Sartori A, Andreuccetti J, Trojan D, Scudo G, Motta A, Pugno NM. Stapled fascial suture: ex vivo modeling and clinical implications. Surg Endosc 2022; 36:8797-8806. [PMID: 35578046 DOI: 10.1007/s00464-022-09304-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 04/23/2022] [Indexed: 01/06/2023]
Abstract
BACKGROUND Recently, in the field of abdominal wall repair surgery, some minimally invasive procedures introduced the use of staplers to provide a retromuscular prosthetic repair. However, to the knowledge of the authors, there are little data in the literature about the outcomes of stapled sutures adoption for midline reconstruction. This study aims to investigate the biomechanics of stapled sutures, simple (stapled), or oversewn (hybrid), in comparison with handsewn suture. From the results obtained, we tried to draw indications for their use in a clinical context. METHODS Human cadaver fascia lata specimens, sutured (handsewn, stapled, or hybrid) or not, underwent tensile tests. The data on strength (maximal stress), ultimate strain (deformability), Young's modulus (rigidity), and dissipated specific energy (ability to absorb mechanical energy up to the breaking point) were recorded for each type of specimens and analyzed. RESULTS Stapled and hybrid suture showed a significantly higher strength (handsewn 0.83 MPa, stapled 2.10 MPa, hybrid 2.68 MPa) and a trend toward a lower ultimate strain as compared to manual sutures (handsewn 344%, stapled 249%, hybrid 280%). Stapled and hybrid sutures had fourfold higher Young's modulus as compared to handsewn sutures (handsewn 1.779 MPa, stapled 7.374 MPa, hybrid 6.964 MPa). Handsewn and hybrid sutures showed significantly higher dissipated specific energy (handsewn 0.99 mJ-mm3, stapled 0.73 mJ-mm3, hybrid 1.35 mJ-mm3). CONCLUSION Stapled sutures can resist high loads, but are less deformable and rigid than handsewn suture. This suggests a safer employment in case of small defects or diastasis (< W1 in accord to EHS classification), where the presumed tissutal displacement is minimal. Oversewing a stapled suture improves its efficiency, becoming crucial in case of larger defects (> W1 in accord to EHS classification) where the expected tissutal displacement is maximal. Hybrid sutures seem to be a good compromise.
Collapse
Affiliation(s)
- Enrico Lauro
- Department of General Surgery, St. Maria Del Carmine Hospital, Rovereto, Italy.
| | - Ilaria Corridori
- Laboratory for Bioinspired, Bionic, Nano, Meta Materials and Mechanics, Department of Civil, Environmental and Mechanical Engineering, University of Trento, Trento, Italy
- BIOtech Center for Biomedical Technologies, Department of Industrial Engineering, University of Trento, Trento, Italy
| | - Lorenzo Luciani
- Robotic Unit and Department of Urology, Santa Chiara Hospital, Trento, Italy
| | - Alberto Di Leo
- Department of General Surgery, San Camillo Hospital, Trento, Italy
| | - Alberto Sartori
- Department of General Surgery, Montebelluna-Castelfranco Veneto Hospital, Treviso, Italy
| | - Jacopo Andreuccetti
- Department of General Surgery 2^, ASST Spedali Civili di Brescia, Brescia, Italy
| | - Diletta Trojan
- Fondazione Banca dei Tessuti Treviso FBTV, Treviso, Italy
| | - Giovanni Scudo
- Department of General Surgery, St. Maria Del Carmine Hospital, Rovereto, Italy
| | - Antonella Motta
- BIOtech Center for Biomedical Technologies, Department of Industrial Engineering, University of Trento, Trento, Italy
| | - Nicola M Pugno
- Laboratory for Bioinspired, Bionic, Nano, Meta Materials and Mechanics, Department of Civil, Environmental and Mechanical Engineering, University of Trento, Trento, Italy.
- School of Engineering and Material Science, Queen Mary University of London, London, UK.
| |
Collapse
|
2
|
Raftopoulos Y, Rajkumar S, Davidson E, Papasavas P. Prospective Randomized Comparison of Linear Endostaplers During Laparoscopic Sleeve Gastrectomy. Obes Surg 2022; 32:3472-3480. [PMID: 35974292 DOI: 10.1007/s11695-022-06240-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 08/05/2022] [Accepted: 08/09/2022] [Indexed: 10/15/2022]
Abstract
PURPOSE The development of Laparoscopic Linear Endostaplers (LLES) is crucial in minimally invasive approaches in bariatric surgery, but there have been very few published studies comparing 6-row LLES in Laparoscopic Sleeve Gastrectomy (LSG). The objective of this study was to compare two 6-row LLES in LSG. METHODS A total of 60 patients were prospectively randomized to undergo LSG with either Medtronic Endo GIA™ Tri-Staple technology (MTS) or AEON ™ Endostapler(Lexington Medical) LLES. The measured parameters included patient demographics, comorbidity indices, LLES and specimen characteristics, postoperative symptoms, hospital stay, and total adverse events (AEs). Intraoperative bleeding was evaluated using five laparoscopic and corresponding endoscopic images of staple line before clip application, compared with a 1-5 Visual Analogue Scale (VAS), assessed by an independent bariatric surgeon who was blinded to the LLES used. Images of all cases were reviewed on the same day to increase test-retest reliability. RESULTS Both groups were similar in patient demographics. Compared to MTS, AEON LLES group had significantly lower bleeding VAS scores in 4/5 laparoscopic images (pre-pyloric: 1.7 ± 0.7 vs. 2.36 ± 0.76, p = 0.0007, mid-sleeve: 1.46 ± 0.62 vs. 1.86 ± 0.68, p = 0.019, proximal sleeve: 1.6 ± 0.77 vs. 2.0 ± 0.83, p = 0.038, gastro-esophageal junction: 1.43 ± 0.67 vs. 1.86 ± 0.77, p = 0.014) and 3/5 endoscopic images (pre-pyloric: 1.56 ± 0.56 vs. 2.36 ± 0.76, p = 0.006, incisura: 1.66 ± 0.54 vs. 2.0 ± 0.52, p = 0.021, mid-sleeve: 1.63 ± 0.49 vs. 2.0 ± 0.45, p = 0.005). There was no statistical difference in other parameters. CONCLUSION Both devices were equally safe and effective in terms of LLES and specimen characteristics, patient symptoms, hospital stay, and AEs. Bleeding VAS scores were significantly lower, favoring the AEON LLES.
Collapse
Affiliation(s)
- Yannis Raftopoulos
- Weight Management Program, Holyoke Medical Center, Holyoke, MA, 01040, USA
| | - Shruthi Rajkumar
- Weight Management Program, Holyoke Medical Center, Holyoke, MA, 01040, USA.
| | - Elana Davidson
- Weight Management Program, Holyoke Medical Center, Holyoke, MA, 01040, USA
| | - Pavlos Papasavas
- Medical and Surgical Weight Loss Center, Hartford Hospital, Hartford, CT, 06106, USA
| |
Collapse
|
3
|
Gangemi A, Suarez DF. Short-Term Clinical Outcomes of Robotic Sleeve Gastrectomy in Super- and Super-Superobese Patients With and Without Tissue Reinforcement. A Prospective Cohort Matched Study. Obes Surg 2022; 32:202-206. [PMID: 34331188 DOI: 10.1007/s11695-021-05615-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2021] [Revised: 07/12/2021] [Accepted: 07/20/2021] [Indexed: 12/15/2022]
Affiliation(s)
- Antonio Gangemi
- General, Minimally Invasive and Robotic Surgery, Department of Surgery, University of Illinois at Chicago, 840 S Wood, Suite 435E (MC 958), Chicago, IL, 60612, USA.
| | - Daniel F Suarez
- General, Minimally Invasive and Robotic Surgery, Department of Surgery, University of Illinois at Chicago, 840 S Wood, Suite 435E (MC 958), Chicago, IL, 60612, USA
| |
Collapse
|
4
|
Bonnet B, Tabiai I, Rakovich G, Gosselin FP, Villemure I. Air leaks: Stapling affects porcine lungs biomechanics. J Mech Behav Biomed Mater 2021; 125:104883. [PMID: 34678619 DOI: 10.1016/j.jmbbm.2021.104883] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 05/28/2021] [Accepted: 10/02/2021] [Indexed: 11/19/2022]
Abstract
During thoracic operations, surgical staplers resect cancerous tumors and seal the spared lung. However, post-operative air leaks are undesirable clinical consequences: staple legs wound lung tissue. Subsequent to this trauma, air leaks from lung tissue into the pleural space. This affects the lung's physiology and patients' recovery. The objective is to biomechanically and visually characterize porcine lung tissue with and without staples in order to gain knowledge on air leakage following pulmonary resection. Therefore, a syringe pump filled with air inflates and deflates eleven porcine lungs cyclically without exceeding 10 cmH2O of pressure. Cameras capture stereo-images of the deformed lung surface at regular intervals while a microcontroller simultaneously records the alveolar pressure and the volume of air pumped. The raw images are then used to compute tri-dimensional displacements and strains with the Digital Image Correlation method (DIC). Air bubbles originated at staple holes of inner row from exposed porcine lung tissue due to torn pleural on costal surface. Compared during inflation, left upper or lower lobe resections have similar compliance (slope of the pressure vs volume curve), which are 9% lower than healthy lung compliance. However, lower lobes statistically burst at lower pressures than upper lobes (p-value<0.046) in ex vivo conditions confirming previous clinical in vivo studies. In parallel, the lung deformed mostly in the vicinity of staple holes and presented maximum shear strain near the observed leak location. To conclude, a novel technique DIC provided concrete evidence of the post-operative air leaks biomechanics. Further studies could investigate causal relationships between the mechanical parameters and the development of an air leak.
Collapse
Affiliation(s)
- Bénédicte Bonnet
- Department of Mechanical Engineering, Polytechnique Montréal, 2500 Chemin de Polytechnique, Montreal, QC, H3T 1J4, Canada.
| | - Ilyass Tabiai
- Department of Mechanical Engineering, Polytechnique Montréal, 2500 Chemin de Polytechnique, Montreal, QC, H3T 1J4, Canada.
| | - George Rakovich
- Department of Thoracic Surgery, University of Montréal, 2900 Boulevard Edouard-Montpetit, Montreal, QC, H3T 1J4, Canada.
| | - Frédérick P Gosselin
- Department of Mechanical Engineering, Polytechnique Montréal, 2500 Chemin de Polytechnique, Montreal, QC, H3T 1J4, Canada.
| | - Isabelle Villemure
- Department of Mechanical Engineering, Polytechnique Montréal, 2500 Chemin de Polytechnique, Montreal, QC, H3T 1J4, Canada.
| |
Collapse
|
5
|
Liu CY, Hsu PK, Leong KI, Ting CK, Tsou MY. Is tubeless uniportal video-assisted thoracic surgery for pulmonary wedge resection a safe procedure? Eur J Cardiothorac Surg 2021; 58:i70-i76. [PMID: 32182334 DOI: 10.1093/ejcts/ezaa061] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Revised: 01/14/2020] [Accepted: 02/04/2020] [Indexed: 01/22/2023] Open
Abstract
OBJECTIVES Tubeless uniportal video-assisted thoracic surgery (VATS), using a uniportal approach and non-intubated anaesthesia while avoiding postoperative chest drain insertion, for patients undergoing thoracoscopic surgery has been demonstrated to be feasible in selected cases. However, to date, the safety of the procedure has not been studied. METHODS We reviewed consecutive patients undergoing non-intubated uniportal VATS for pulmonary wedge resection at 2 medical centres between August 2016 and October 2019. The decision to avoid chest drain insertion was made in selected candidates. For those candidates in whom a tubeless procedure was performed, postoperative chest X-rays (CXRs) were taken on the day of the surgery [operation (OP) day], on postoperative day 1 and 1-2 weeks later. The factors associated with abnormal CXR findings were studied. RESULTS Among 135 attempts to avoid chest drain insertion, 13 (9.6%) patients ultimately required a postoperative chest drain. Among 122 patients in which a tubeless procedure was performed, 26 (21.3%) and 47 (38.5%) had abnormal CXR findings on OP day and postoperative day 1, respectively. Among them, 3 (2.5%) patients developed clinically significant abnormal CXRs and required intercostal drainage. Primary spontaneous pneumothorax was independently associated with a higher risk of postoperative abnormal CXRs. CONCLUSIONS Tubeless uniportal VATS for pulmonary wedge resection can be safely performed in selected patients. Most patients with postoperative abnormal CXRs presented subclinical symptoms that spontaneously resolved; only 2.5% of patients with postoperative abnormal CXRs required drainage.
Collapse
Affiliation(s)
- Chao-Yu Liu
- School of Medicine, National Yang-Ming University, Taipei, Taiwan.,Division of Thoracic Surgery, Department of Surgery, Far-Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Po-Kuei Hsu
- School of Medicine, National Yang-Ming University, Taipei, Taiwan.,Division of Thoracic Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Ka-I Leong
- Division of Thoracic Surgery, Department of Surgery, Far-Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Chien-Kun Ting
- School of Medicine, National Yang-Ming University, Taipei, Taiwan.,Department of Anesthesiology, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Mei-Yung Tsou
- School of Medicine, National Yang-Ming University, Taipei, Taiwan.,Department of Anesthesiology, Taipei Veterans General Hospital, Taipei, Taiwan
| |
Collapse
|
6
|
Zeng J, Wu X, Chen Z, Zhang M, Ke M. Modified silicone stent for the treatment of post-surgical bronchopleural fistula: a clinical observation of 17 cases. BMC Pulm Med 2021; 21:10. [PMID: 33407326 PMCID: PMC7789393 DOI: 10.1186/s12890-020-01372-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Accepted: 12/11/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Bronchopleural fistula is a rare but life-threatening event with limited therapeutic options. We aimed to investigate the efficacy and safety of the modified silicone stent in patients with post-surgical bronchopleural fistula. METHODS Between March 2016 and April 2020, we retrospectively reviewed the records of 17 patients with bronchopleural fistula and who underwent bronchoscopic placement of the Y-shaped silicone stent. The rate of initial success, clinical success and clinical cure, and complications were analyzed. RESULTS Stent placement was successful in 16 patients in the first attempt (initial success rate: 94.1%). The median follow-up time was 107 (range, 5-431) days. All patients achieved amelioration of respiratory symptoms. The clinical success rate was 76.5%. Of the 14 patients with empyema, the daily drainage was progressively decreased in 11 patients, and empyema completely disappeared in six patients. Seven stents were removed during follow-up: four (26.7%) for the cure of fistula, two for severe proliferation of granulomatous tissue and one for stent dislocation. No severe adverse events (i.e. massive hemoptysis, suture dehiscence) took place. Seven patients died (due to progression of malignancy, uncontrolled infection, myocardial infarction and left heart failure). CONCLUSIONS The modified silicone stent may be an effective and safe option for patients with post-surgical bronchopleural fistula patients in whom conventional therapy is contraindicated.
Collapse
Affiliation(s)
- Junli Zeng
- Department of Respiratory Centre, The Second Affiliated Hospital of Xiamen Medical College, 566 Shengguang Road, Xiamen, 361000, Fujian Province, China
| | - Xuemei Wu
- Department of Respiratory Centre, The Second Affiliated Hospital of Xiamen Medical College, 566 Shengguang Road, Xiamen, 361000, Fujian Province, China
| | - Zhide Chen
- Department of Respiratory Centre, The Second Affiliated Hospital of Xiamen Medical College, 566 Shengguang Road, Xiamen, 361000, Fujian Province, China
| | - Meihua Zhang
- Department of Respiratory Centre, The Second Affiliated Hospital of Xiamen Medical College, 566 Shengguang Road, Xiamen, 361000, Fujian Province, China
| | - Mingyao Ke
- Department of Respiratory Centre, The Second Affiliated Hospital of Xiamen Medical College, 566 Shengguang Road, Xiamen, 361000, Fujian Province, China.
| |
Collapse
|
7
|
Customized airway stenting for bronchopleural fistula after pulmonary resection by interventional technique: single-center study of 148 consecutive patients. Surg Endosc 2018; 32:4116-4124. [DOI: 10.1007/s00464-018-6152-x] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2017] [Accepted: 03/21/2018] [Indexed: 10/17/2022]
|