1
|
Zhang Y, Lai J, Zhao C, Wang J, Yan Y, Chen M, Ji L, Guo J, Han B, Shi Y, Chen Y, Yang W, Feng Q. Abnormal recognition-assisted and onset-offset aware network for pathological wearable ECG delineation. Artif Intell Med 2024; 157:102992. [PMID: 39369633 DOI: 10.1016/j.artmed.2024.102992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 08/19/2024] [Accepted: 09/26/2024] [Indexed: 10/08/2024]
Abstract
Electrocardiogram (ECG) delineation is essential to the identification of abnormal cardiac status, especially when ECG signals are remotely monitored with wearable devices. The complexity and diversity of cardiac conditions generate numerous pathological ECG patterns, not only requiring the recognition of normal ECG but also addressing an extensive range of abnormal ECG patterns, posing a challenging task. Therefore, we propose an abnormal recognition-assisted network to integrate supplementary information on diverse ECG patterns. Simultaneously, we design an onset-offset aware loss to enhance precise waveform localization. Specifically, we establish a two-branch framework where ECG delineation serves as the target task, producing the final segmentation results. Additionally, the abnormal recognition-assisted network serves as an auxiliary task, extracting multi-label pathological information from ECGs. This joint learning approach establishes crucial correlations between ECG delineation and associated ECG abnormalities. The correlations enable the model to demonstrate sufficient generalization in the presence of diverse abnormal ECG patterns. Besides, onset-offset aware loss focuses intensively on wave onsets and offsets by applying biased weights to various waveform positions. This approach ensures a focus on precise localization, facilitating seamless integration into cross-entropy loss function. A large-scale wearable 12-lead dataset containing 4,913 signals is collected, offering an extensive range of ECG data for model training. Results demonstrate that our method achieves outstanding performance on two test datasets, attaining sensitivity of 94.97% and 94.27% and an error tolerance lower than 20 ms. Furthermore, our method is effective for various aberrant ECG signals, including ST-segment changes, atrial premature beats, and right and left bundle branch blocks.
Collapse
Affiliation(s)
- Yue Zhang
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Guangzhou, China
| | - Jiewei Lai
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Guangzhou, China
| | - Chenyu Zhao
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Guangzhou, China
| | - Jinliang Wang
- CardioCloud Medical Technology (Beijing) Co. Ltd., Beijing, China
| | - Yong Yan
- CardioCloud Medical Technology (Beijing) Co. Ltd., Beijing, China
| | - Mingyang Chen
- CardioCloud Medical Technology (Beijing) Co. Ltd., Beijing, China
| | - Lei Ji
- IT Department, Chinese PLA General Hospital, Beijing, China
| | - Jun Guo
- Department of Cardiology, Chinese PLA General Hospital, Beijing, China
| | - Baoshi Han
- Department of Cardiology, Chinese PLA General Hospital, Beijing, China
| | - Yajun Shi
- Department of Cardiology, Chinese PLA General Hospital, Beijing, China
| | - Yundai Chen
- Department of Cardiology, Chinese PLA General Hospital, Beijing, China.
| | - Wei Yang
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Guangzhou, China.
| | - Qianjin Feng
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Guangzhou, China.
| |
Collapse
|
2
|
Liao Z, Shi Z, Sarker MS, Tabata H. Robust QRS detection based on simulated degenerate optical parametric oscillator-assisted neural network. Heliyon 2024; 10:e28903. [PMID: 38576550 PMCID: PMC10990971 DOI: 10.1016/j.heliyon.2024.e28903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 03/22/2024] [Accepted: 03/26/2024] [Indexed: 04/06/2024] Open
Abstract
Accurately detecting the depolarization QRS complex in the ventricles is a fundamental requirement for cardiovascular disease detection using electrocardiography (ECG). In contrast to traditional signal enhancement algorithms, emerging neural network approaches have shown promise for QRS detection because of their generalizability on complex data. However, the inevitable noise present during ECG recording leads to a decrease in the performance of neural networks. To enhance the robustness and performance of neural network-based QRS detectors, we propose a simulated degeneration unit (SDU)-assisted convolutional neural network (CNN). An SDU simulates the physical degeneration process of interfering optical pulses, which can effectively suppress in-band noise. Through comprehensive performance evaluations on three open-source databases, the SDU-enhanced CNN-based approach demonstrated better performance in detecting QRS complexes than other recently reported QRS detectors. Furthermore, real-world noise injection tests indicate that the optimal noise robustness boundary for the CNN equipped with SDU is 167-300% higher than that for the CNN without SDU.
Collapse
Affiliation(s)
- Zhiqiang Liao
- Department of Electrical Engineering and Information Systems, Graduate School of Engineering, The University of Tokyo, Tokyo, 113-8656, Japan
- Department of Bioengineering, Graduate School of Engineering, The University of Tokyo, Tokyo, 113-8656, Japan
| | - Zhuozheng Shi
- Department of Bioengineering, Graduate School of Engineering, The University of Tokyo, Tokyo, 113-8656, Japan
- Bioinformatics Interdepartmental Program, University of California Los Angeles, Los Angeles, CA, USA
| | - Md Shamim Sarker
- Department of Electrical Engineering and Information Systems, Graduate School of Engineering, The University of Tokyo, Tokyo, 113-8656, Japan
- Department of Bioengineering, Graduate School of Engineering, The University of Tokyo, Tokyo, 113-8656, Japan
| | - Hitoshi Tabata
- Department of Electrical Engineering and Information Systems, Graduate School of Engineering, The University of Tokyo, Tokyo, 113-8656, Japan
- Department of Bioengineering, Graduate School of Engineering, The University of Tokyo, Tokyo, 113-8656, Japan
| |
Collapse
|
3
|
Gungor CB, Mercier PP, Toreyin H. A 2.2 nW Analog Electrocardiogram Processor Based on Stochastic Resonance Achieving a 99.94% QRS Complex Detection Sensitivity. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2023; 17:33-44. [PMID: 37018643 DOI: 10.1109/tbcas.2023.3235786] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
This paper presents an ultra-low power electrocardiogram (ECG) processor that can detect QRS-waves in real time as the data streams in. The processor performs out-of-band noise suppression via a linear filter, and in-band noise suppression via a nonlinear filter. The nonlinear filter also enhances the QRS-waves by facilitating stochastic resonance. The processor identifies the QRS-waves on noise-suppressed and enhanced recordings using a constant threshold detector. For energy-efficiency and compactness, the processor exploits current-mode analog signal processing techniques, which significantly reduces the design complexity when implementing the second-order dynamics of the nonlinear filter. The processor is designed and implemented in TSMC 65 nm CMOS technology. In terms of detection performance, the processor achieves an average ${\bm{F}}1 = 99.88{\bm{\% }}$ over the MIT-BIH Arrhythmia database and outperforms all previous ultra-low power ECG processors. The processor is the first that is validated against noisy ECG recordings of MIT-BIH NST and TELE databases, where it achieves better detection performances than most digital algorithms run on digital platforms. The design has a footprint of 0.08 mm2 and dissipates 2.2 nW when supplied by a single 1V supply, making it the first ultra-low power and real-time processor that facilitates stochastic resonance.
Collapse
|
4
|
Gungor CB, Mercier PP, Toreyin H. A Stochastic Resonance Electrocardiogram Enhancement Algorithm for Robust QRS Detection. IEEE J Biomed Health Inform 2022; 26:3743-3754. [PMID: 35617182 DOI: 10.1109/jbhi.2022.3178109] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This study presents a new QRS detection algorithm making use of the background noise that is inevitably present in electrocardiogram (ECG) recordings. The algorithm suppresses noise, enhances the QRS-waves, and applies a threshold for QRS detection. Noise suppression and QRS enhancement are performed by a band-pass filter stage followed by a nonlinear stage based on the interaction of a particle inside an underdamped monostable potential well. The nonlinear stage maximizes the output when there is a QRS-wave and minimizes the output otherwise. One of the instruments that the nonlinear stage uses to enhance the QRS-waves is stochastic resonance, where the output is maximized for a non-zero intensity background noise. In terms of QRS-wave detection F1 score, which ranges from 98.87% to 99.99% on four major benchmarking databases (MIT-BIH Arrhythmia, QT, European ST-T, and MIT-BIH Noise Stress Test), the algorithm outperforms all existing ECG processing algorithms. The study, for the first time, demonstrates QRS-enhancement by facilitating stochastic resonance while suppressing in-band noise of ECG signals. Detecting QRS-waves as the ECG data streams, having a complexity of O(n), and not requiring any training data make the algorithm convenient for real-time ECG monitoring applications with limited computational resources.
Collapse
|