1
|
Ataka M, Otomo K, Enoki R, Ishii H, Tsutsumi M, Kozawa Y, Sato S, Nemoto T. Multibeam continuous axial scanning two-photon microscopy for in vivo volumetric imaging in mouse brain. BIOMEDICAL OPTICS EXPRESS 2024; 15:1089-1101. [PMID: 38404301 PMCID: PMC10890896 DOI: 10.1364/boe.514826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 01/12/2024] [Accepted: 01/15/2024] [Indexed: 02/27/2024]
Abstract
This study presents an alternative approach for two-photon volumetric imaging that combines multibeam lateral scanning with continuous axial scanning using a confocal spinning-disk scanner and an electrically focus tunable lens. Using this proposed system, the brain of a living mouse could be imaged at a penetration depth of over 450 μm from the surface. In vivo volumetric Ca2+ imaging at a volume rate of 1.5 Hz within a depth range of 130-200 μm, was segmented with an axial pitch of approximately 5-µm and revealed spontaneous activity of neurons with their 3D positions. This study offers a practical microscope design equipped with compact scanners, a simple control system, and readily adjustable imaging parameters, which is crucial for the widespread adoption of two-photon volumetric imaging.
Collapse
Affiliation(s)
- Mitsutoshi Ataka
- National Institute for Physiological Sciences, National Institutes of Natural Sciences, Okazaki 444-8787, Japan
| | - Kohei Otomo
- National Institute for Physiological Sciences, National Institutes of Natural Sciences, Okazaki 444-8787, Japan
- Exploratory Research Center on Life and Living Systems (ExCELLS), National Institutes of Natural Sciences, Okazaki 444-8787, Japan
- Graduate School of Medicine, Juntendo University, Tokyo 113-8421, Japan
| | - Ryosuke Enoki
- National Institute for Physiological Sciences, National Institutes of Natural Sciences, Okazaki 444-8787, Japan
- Exploratory Research Center on Life and Living Systems (ExCELLS), National Institutes of Natural Sciences, Okazaki 444-8787, Japan
- School of Life Sciences, The Graduate School of Advanced Studies, SOKENDAI, Okazaki 444-8787, Japan
| | - Hirokazu Ishii
- National Institute for Physiological Sciences, National Institutes of Natural Sciences, Okazaki 444-8787, Japan
- Exploratory Research Center on Life and Living Systems (ExCELLS), National Institutes of Natural Sciences, Okazaki 444-8787, Japan
- School of Life Sciences, The Graduate School of Advanced Studies, SOKENDAI, Okazaki 444-8787, Japan
| | - Motosuke Tsutsumi
- National Institute for Physiological Sciences, National Institutes of Natural Sciences, Okazaki 444-8787, Japan
- Exploratory Research Center on Life and Living Systems (ExCELLS), National Institutes of Natural Sciences, Okazaki 444-8787, Japan
- School of Life Sciences, The Graduate School of Advanced Studies, SOKENDAI, Okazaki 444-8787, Japan
| | - Yuichi Kozawa
- Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577, Japan
| | - Shunichi Sato
- Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577, Japan
| | - Tomomi Nemoto
- National Institute for Physiological Sciences, National Institutes of Natural Sciences, Okazaki 444-8787, Japan
- Exploratory Research Center on Life and Living Systems (ExCELLS), National Institutes of Natural Sciences, Okazaki 444-8787, Japan
- School of Life Sciences, The Graduate School of Advanced Studies, SOKENDAI, Okazaki 444-8787, Japan
| |
Collapse
|
2
|
Tanimoto M, Watakabe I, Higashijima SI. Tiltable objective microscope visualizes selectivity for head motion direction and dynamics in zebrafish vestibular system. Nat Commun 2022; 13:7622. [PMID: 36543769 PMCID: PMC9772181 DOI: 10.1038/s41467-022-35190-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Accepted: 11/16/2022] [Indexed: 12/24/2022] Open
Abstract
Spatio-temporal information about head orientation and movement is fundamental to the sense of balance and motion. Hair cells (HCs) in otolith organs of the vestibular system transduce linear acceleration, including head tilt and vibration. Here, we build a tiltable objective microscope in which an objective lens and specimen tilt together. With in vivo Ca2+ imaging of all utricular HCs and ganglion neurons during 360° static tilt and vibration in pitch and roll axes, we reveal the direction- and static/dynamic stimulus-selective topographic responses in larval zebrafish. We find that head vibration is preferentially received by striolar HCs, whereas static tilt is preferentially transduced by extrastriolar HCs. Spatially ordered direction preference in HCs is consistent with hair-bundle polarity and is preserved in ganglion neurons through topographic innervation. Together, these results demonstrate topographically organized selectivity for direction and dynamics of head orientation/movement in the vestibular periphery.
Collapse
Affiliation(s)
- Masashi Tanimoto
- grid.419396.00000 0004 0618 8593Division of Behavioral Neurobiology, National Institute for Basic Biology, Okazaki, Aichi 444-8787 Japan ,grid.250358.90000 0000 9137 6732Neuronal Networks Research Group, Exploratory Research Center on Life and Living Systems (ExCELLS), Okazaki, Aichi 444-8787 Japan
| | - Ikuko Watakabe
- grid.419396.00000 0004 0618 8593Division of Behavioral Neurobiology, National Institute for Basic Biology, Okazaki, Aichi 444-8787 Japan ,grid.250358.90000 0000 9137 6732Neuronal Networks Research Group, Exploratory Research Center on Life and Living Systems (ExCELLS), Okazaki, Aichi 444-8787 Japan
| | - Shin-ichi Higashijima
- grid.419396.00000 0004 0618 8593Division of Behavioral Neurobiology, National Institute for Basic Biology, Okazaki, Aichi 444-8787 Japan ,grid.250358.90000 0000 9137 6732Neuronal Networks Research Group, Exploratory Research Center on Life and Living Systems (ExCELLS), Okazaki, Aichi 444-8787 Japan
| |
Collapse
|
3
|
Single-scan volumetric imaging throughout thick tissue specimens by one-touch installable light-needle creating device. Sci Rep 2022; 12:10468. [PMID: 35729283 PMCID: PMC9213396 DOI: 10.1038/s41598-022-14647-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Accepted: 06/09/2022] [Indexed: 11/23/2022] Open
Abstract
Biological tissues and their networks frequently change dynamically across large volumes. Understanding network operations requires monitoring their activities in three dimensions (3D) with single-cell resolution. Several researchers have proposed various volumetric imaging technologies. However, most technologies require large-scale and complicated optical setups, as well as deep expertise for microscopic technologies, resulting in a high threshold for biologists. In this study, we propose an easy-to-use light-needle creating device for conventional two-photon microscopy systems. By only installing the device in one position for a filter cube that conventional fluorescent microscopes have, single scanning of the excitation laser light beam excited fluorophores throughout over 200 μm thickness specimens simultaneously. Furthermore, the developed microscopy system successfully demonstrated single-scan visualization of the 3D structure of transparent YFP-expressing brain slices. Finally, in acute mouse cortical slices with a thickness of approximately 250 μm, we detected calcium activities with 7.5 Hz temporal resolution in the neuronal population.
Collapse
|
4
|
Low-invasive 5D visualization of mitotic progression by two-photon excitation spinning-disk confocal microscopy. Sci Rep 2022; 12:809. [PMID: 35039530 PMCID: PMC8764092 DOI: 10.1038/s41598-021-04543-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Accepted: 12/24/2021] [Indexed: 11/20/2022] Open
Abstract
Non-linear microscopy, such as multi-photon excitation microscopy, offers spatial localities of excitations, thereby achieving 3D cross-sectional imaging with low phototoxicity even in thick biological specimens. We had developed a multi-point scanning two-photon excitation microscopy system using a spinning-disk confocal scanning unit. However, its severe color cross-talk has precluded multi-color simultaneous imaging. Therefore, in this study, we introduced a mechanical switching system to select either of two NIR laser light pulses and an image-splitting detection system for 3- or 4-color imaging. As a proof of concept, we performed multi-color fluorescent imaging of actively dividing human HeLa cells and tobacco BY-2 cells. We found that the proposed microscopy system enabled time-lapse multi-color 3D imaging of cell divisions while avoiding photodamage. Moreover, the application of a linear unmixing method to the 5D dataset enabled the precise separation of individual intracellular components in multi-color images. We thus demonstrated the versatility of our new microscopy system in capturing the dynamic processes of cellular components that could have multitudes of application.
Collapse
|
5
|
Le Corre K, Robin T, Cadier B, Becheker R, Godin T, Hideur A, Gilles H, Girard S, Laroche M. Mode-locked all-PM Nd-doped fiber laser near 910 nm. OPTICS LETTERS 2021; 46:3564-3567. [PMID: 34329225 DOI: 10.1364/ol.433313] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 06/28/2021] [Indexed: 06/13/2023]
Abstract
We present a compact passively mode-locked fiber laser emitting near 910 nm with an all-polarization-maintaining fiber laser architecture. The ring-cavity laser configuration includes a core-pumped neodymium-doped fiber as a gain medium and a semiconductor saturable absorber mirror as a passive mode-locking element. A bandpass filter is used to suppress parasitic emission near 1.06 µm and allows wavelength tuning between 903 and 912 nm. The laser operates in a highly stable and self-starting all-normal-dispersion regime with a minimum pulse duration of 8 ps at 28.2 MHz pulse repetition rate and 0.2 nJ maximum pulse energy. A single-pass amplifier stage increases the pulse energy up to 1.5 nJ, and pulse compression with a pair of gratings is demonstrated with nearly Fourier transform limited pulses.
Collapse
|