1
|
Luo X, Li M, Cai H, Yang S, Hao L, Ebel T, Helmholz H, Huang B, Wang X. Degradation Adaptability Assessment of Semisolid Powder Molded Mg-Zn-Mn Alloys for Orthopedic Applications. ACS APPLIED BIO MATERIALS 2023; 6:5515-5530. [PMID: 37982492 DOI: 10.1021/acsabm.3c00710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2023]
Abstract
Semisolid powder molding was used to prepare the medical Mg-6Zn alloy; in order to further improve its degradation adaptability, 0.5 and 1 wt % Mn were added. Then, the effect of the forming temperature (540, 560, 580, and 600 °C) on the in vitro degradation behavior of the prepared Mg-6Zn-xMn (x = 0.5, 1 wt %) was analyzed, and the optimized alloy was obtained. Finally, the biocompatibility and in vivo degradation performance of the optimized and Mn-free alloys were evaluated. Importantly, single-photon emission tomographic imaging (SPECT/CT) was first applied to monitor the in vivo degradation process. The results show that the corrosion mechanism of the Mn-free alloy is microgalvanic corrosion control with corrosive pitting. After adding Mn, the in vitro degradation rate decreases by half (0.17 ± 0.01 mm/year) as the forming temperature increases to 600 °C, and Mg-6Zn-1Mn prepared at 600 °C is the optimized alloy. Mn addition improves the corrosion product film protection and discontinuous secondary phases, and thus, the corrosion mechanism is changed to corrosive pitting control. Additionally, semisolid powder molding is an easy method to prepare alloys with low average pore interconnectivity (<10%), which is helpful for slowing down the degradation rate. The Mn-containing alloy has better biocompatibility, with a cytotoxicity of grade 0-1, due to its lower degradation rate. The in vivo corrosion rate of the Mn-free alloy is 0.19 mm/year after 28 days of implantation, which was precisely detected by SPECT/CT in real-time. The long-term in vivo degradation adaptability of Mn-free and Mn-containing alloys was not correctly presented, which may be due to the unreasonable bone defect model causing implant displacement. However, both of these alloys cause no obvious inflammation and show good healing. In summary, semisolid powder molding is a potentially promising technique to prepare medical Mg alloys, and nuclear imaging is an effective in vivo degradation evaluation method.
Collapse
Affiliation(s)
- Xia Luo
- School of New Energy and Materials, Southwest Petroleum University, Chengdu 610500, P. R. China
| | - Mingyu Li
- School of New Energy and Materials, Southwest Petroleum University, Chengdu 610500, P. R. China
- Department of Nuclear Medicine & Laboratary of Clinical Nuclear Medicine, West China Hospital of Sichuan University, Chengdu 610041, P. R. China
| | - Huawei Cai
- Department of Nuclear Medicine & Laboratary of Clinical Nuclear Medicine, West China Hospital of Sichuan University, Chengdu 610041, P. R. China
| | - Shanghui Yang
- School of New Energy and Materials, Southwest Petroleum University, Chengdu 610500, P. R. China
| | - Lijing Hao
- National Engineering Research Center for Tissue Restoration and Reconstruction, School of Materials Science and Engineering, South China University of Technology, Guangzhou 510006, P. R. China
| | - Thomas Ebel
- Institute of Metallic Biomaterials, Helmholtz-Zentrum Hereon GmbH, 21502 Geesthacht, Germany
| | - Heike Helmholz
- Institute of Metallic Biomaterials, Helmholtz-Zentrum Hereon GmbH, 21502 Geesthacht, Germany
| | - Bensheng Huang
- School of New Energy and Materials, Southwest Petroleum University, Chengdu 610500, P. R. China
| | - Xiaohong Wang
- School of New Energy and Materials, Southwest Petroleum University, Chengdu 610500, P. R. China
| |
Collapse
|
2
|
Martinez DC, Dobkowska A, Marek R, Ćwieka H, Jaroszewicz J, Płociński T, Donik Č, Helmholz H, Luthringer-Feyerabend B, Zeller-Plumhoff B, Willumeit-Römer R, Święszkowski W. In vitro and in vivo degradation behavior of Mg-0.45Zn-0.45Ca (ZX00) screws for orthopedic applications. Bioact Mater 2023; 28:132-154. [PMID: 37250863 PMCID: PMC10209338 DOI: 10.1016/j.bioactmat.2023.05.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 04/26/2023] [Accepted: 05/09/2023] [Indexed: 05/31/2023] Open
Abstract
Magnesium (Mg) alloys have become a potential material for orthopedic implants due to their unnecessary implant removal, biocompatibility, and mechanical integrity until fracture healing. This study examined the in vitro and in vivo degradation of an Mg fixation screw composed of Mg-0.45Zn-0.45Ca (ZX00, in wt.%). With ZX00 human-sized implants, in vitro immersion tests up to 28 days under physiological conditions, along with electrochemical measurements were performed for the first time. In addition, ZX00 screws were implanted in the diaphysis of sheep for 6, 12, and 24 weeks to assess the degradation and biocompatibility of the screws in vivo. Using scanning electron microscopy (SEM) coupled with energy dispersive X-ray spectroscopy (EDX), micro-computed tomography (μCT), X-ray photoelectron spectroscopy (XPS), and histology, the surface and cross-sectional morphologies of the corrosion layers formed, as well as the bone-corrosion-layer-implant interfaces, were analyzed. Our findings from in vivo testing demonstrated that ZX00 alloy promotes bone healing and the formation of new bone in direct contact with the corrosion products. In addition, the same elemental composition of corrosion products was observed for in vitro and in vivo experiments; however, their elemental distribution and thicknesses differ depending on the implant location. Our findings suggest that the corrosion resistance was microstructure-dependent. The head zone was the least corrosion-resistant, indicating that the production procedure could impact the corrosion performance of the implant. In spite of this, the formation of new bone and no adverse effects on the surrounding tissues demonstrated that the ZX00 is a suitable Mg-based alloy for temporary bone implants.
Collapse
Affiliation(s)
- Diana C. Martinez
- Biomaterials Group, Materials Design Division, Faculty of Materials Science and Engineering, Warsaw University of Technology, Wołoska 141, 02-507, Warsaw, Poland
| | - Anna Dobkowska
- Biomaterials Group, Materials Design Division, Faculty of Materials Science and Engineering, Warsaw University of Technology, Wołoska 141, 02-507, Warsaw, Poland
| | - Romy Marek
- Department of Orthopedics and Traumatology, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Hanna Ćwieka
- Institute of Metallic Biomaterials, Helmholtz-Zentrum Hereon GmbH, 21502, Geesthacht, Germany
| | - Jakub Jaroszewicz
- Biomaterials Group, Materials Design Division, Faculty of Materials Science and Engineering, Warsaw University of Technology, Wołoska 141, 02-507, Warsaw, Poland
| | - Tomasz Płociński
- Biomaterials Group, Materials Design Division, Faculty of Materials Science and Engineering, Warsaw University of Technology, Wołoska 141, 02-507, Warsaw, Poland
| | - Črtomir Donik
- Department of Physics and Chemistry of Materials, Institute of Metals and Technology, University of Ljubljana, Lepi Pot 11, SI-1000, Ljubljana, Slovenia
| | - Heike Helmholz
- Institute of Metallic Biomaterials, Helmholtz-Zentrum Hereon GmbH, 21502, Geesthacht, Germany
| | | | - Berit Zeller-Plumhoff
- Institute of Metallic Biomaterials, Helmholtz-Zentrum Hereon GmbH, 21502, Geesthacht, Germany
| | - Regine Willumeit-Römer
- Institute of Metallic Biomaterials, Helmholtz-Zentrum Hereon GmbH, 21502, Geesthacht, Germany
| | - Wojciech Święszkowski
- Biomaterials Group, Materials Design Division, Faculty of Materials Science and Engineering, Warsaw University of Technology, Wołoska 141, 02-507, Warsaw, Poland
| |
Collapse
|
3
|
Kwesiga MP, Gillette AA, Razaviamri F, Plank ME, Canull AL, Alesch Z, He W, Lee BP, Guillory RJ. Biodegradable magnesium materials regulate ROS-RNS balance in pro-inflammatory macrophage environment. Bioact Mater 2023; 23:261-273. [PMID: 36439083 PMCID: PMC9678810 DOI: 10.1016/j.bioactmat.2022.10.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 09/21/2022] [Accepted: 10/11/2022] [Indexed: 11/19/2022] Open
Abstract
The relationship between reactive oxygen and nitrogen species (ROS-RNS) secretion and the concomitant biocorrosion of degradable magnesium (Mg) materials is poorly understood. We found that Mg foils implanted short term in vivo (24 h) displayed large amounts of proinflammatory F4/80+/iNOS + macrophages at the interface. We sought to investigate the interplay between biodegrading Mg materials (98.6% Mg, AZ31 & AZ61) and macrophages (RAW 264.7) stimulated with lipopolysaccharide (RAW 264.7LPS) to induce ROS-RNS secretion. To test how these proinflammatory ROS-RNS secreting cells interact with Mg corrosion in vitro, Mg and AZ61 discs were suspended approximately 2 mm above a monolayer of RAW 264.7 cells, either with or without LPS. The surfaces of both materials showed acute (24 h) changes when incubated in the proinflammatory RAW 264.7LPS environment. Mg discs incubated with RAW 264.7LPS macrophages showed greater corrosion pitting, while AZ61 showed morphological and elemental bulk product changes via scanning electron microscopy-energy dispersive X-ray spectroscopy (SEM-EDX). X-ray photoelectron spectroscopy (XPS) analysis showed a reduction in the Ca/P ratio of the surface products for AZ61 disc incubated with RAW 264.7LPS, but not the Mg discs. Moreover, RAW 264.7LPS macrophages were found to be more viable in the acute biodegradative environment generated by Mg materials, as demonstrated by calcein-AM and cleaved (active) caspase-3 staining (CC3). LPS stimulation caused an increase in ROS-RNS, and a decrease in antioxidant peroxidase activity. Mg and AZ61 were found to change this ROS-RNS balance, independently of physiological antioxidant mechanisms. The findings highlight the complexity of the cellular driven acute inflammatory responses to different biodegradable Mg, and how it can potentially affect performance of these materials.
Collapse
|
4
|
Shan Z, Xie X, Wu X, Zhuang S, Zhang C. Development of degradable magnesium-based metal implants and their function in promoting bone metabolism (A review). J Orthop Translat 2022; 36:184-193. [PMID: 36263386 PMCID: PMC9552026 DOI: 10.1016/j.jot.2022.09.013] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 09/05/2022] [Accepted: 09/26/2022] [Indexed: 11/06/2022] Open
Abstract
Background Use of degradable magnesium (Mg)-based metal implants in orthopaedic surgeries can avoid drawbacks associated with subsequent removal of the non-degradable metallic implants, reducing cost and trauma of patients. Although Mg has been applied in the clinic for orthopaedic treatment, the use of Mg-based metal implants is largely in the research phase. But its application is potentially beneficial in this context as it has been shown that Mg can promote osteogenesis and inhibit osteoclast activity. Methods A systematic literature search about “degradable magnesium (Mg)-based metal implants” was performed in PubMed and Web of Science. Meanwhile, relevant findings have been reviewed and quoted. Results In this review, we summarize the latest developments in Mg-based metal implants and their role in bone regeneration. We also review the various molecular mechanisms by which Mg ions regulate bone metabolic processes, including osteogenesis, osteoclast activity, angiogenesis, immunity, and neurology. Finally, we discuss the remaining research challenges and opportunities for Mg-based implants and their applications. Conclusion Currently, establishment of the in vitro and in vivo biological evaluation systems and phenotypic modification improvement of Mg-based implants are still needed. Clarifying the functions of Mg-based metal implants in promoting bone metabolism is beneficial for their clinical application. The Translational potential of this article All current reviews on Mg-based implants are mainly concerned with the improvement of Mg alloy properties or the progress of applications. However, there are few reviews that provides a systematic narrative on the effect of Mg on bone metabolism. This review summarized the latest developments in Mg-based metal implants and various molecular mechanisms of Mg ions regulating bone metabolism, which is beneficial to further promote the translation of Mg based implants in the clinic and is able to provide a strong basis for the clinical application of Mg based implants.
Collapse
Affiliation(s)
- Zhengming Shan
- School of Medicine, Southeast University, Nanjing, Jiangsu, 210009, China
| | - Xinhui Xie
- School of Medicine, Southeast University, Nanjing, Jiangsu, 210009, China
- The Department of Orthopaedics, ZhongDa Hospital, Nanjing, Jiangsu, 210009, China
- Corresponding author. The Department of Orthopaedics, ZhongDa hospital, School of Medicine, Southeast University, Nanjing, Jiangsu, 210009, China.
| | - Xiaotao Wu
- School of Medicine, Southeast University, Nanjing, Jiangsu, 210009, China
- The Department of Orthopaedics, ZhongDa Hospital, Nanjing, Jiangsu, 210009, China
- Corresponding author. The Department of Orthopaedics, ZhongDa hospital, School of Medicine, Southeast University, Nanjing, Jiangsu, 210009, China.
| | - Suyang Zhuang
- School of Medicine, Southeast University, Nanjing, Jiangsu, 210009, China
- The Department of Orthopaedics, ZhongDa Hospital, Nanjing, Jiangsu, 210009, China
| | - Cong Zhang
- School of Medicine, Southeast University, Nanjing, Jiangsu, 210009, China
- The Department of Orthopaedics, ZhongDa Hospital, Nanjing, Jiangsu, 210009, China
| |
Collapse
|
5
|
Rajendran R, Dondapati S. Insights of Microstructural Features and Their Effect on Degradation and the In Vitro Bioactivity Response of as-Cast Mg-Sn Alloys for Orthopedic Implant Applications. MATERIALS (BASEL, SWITZERLAND) 2022; 15:6327. [PMID: 36143640 PMCID: PMC9500764 DOI: 10.3390/ma15186327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 08/16/2022] [Accepted: 08/19/2022] [Indexed: 06/16/2023]
Abstract
The present work focuses on a deep understanding of microstructural evolution and phase formation in a binary Mg-Sn alloy system. Mg-xSn (x = 1, 5, 10 wt.%) alloys were cast using a squeeze casting technique. Phase identification and microstructural analysis were done using XRD (X-ray Diffraction) and FESEM with EDS (Field Emission Scanning Electron Microscopy with Energy Dispersive X-ray Spectroscopy), respectively. The mechanical behavior of the alloys under study was evaluated by conducting a compression test. The corrosion behavior of all the alloys were intricately studied using electrochemical corrosion tests and an immersion test in the simulated body fluid (SBF) environment for different immersion periods. The bioactivity response of Mg-Sn alloys systems under this study was investigated by immersing the samples in SBF for 14 days. From the analysis of the results, it was understood that the amount of Sn addition has a large influence on the metallurgical, corrosion, and bioactivity properties. Interesting facts about the intermetallic phase formation and segregation of Sn were observed when the wt.% of Sn was varied in the alloy and the evolution of the microstructure was described clearly. Mechanical properties of Mg-Sn alloys were improved, as the Sn content increased up to 5 wt.% and declined in the case of a 10 wt.% Sn addition. A similar trend was observed even in the case of corrosion resistance and bioactivity properties. Among the alloy compositions studied, Mg with a 5 wt.% addition has proved to be a promising candidate material for orthopedic implant applications with an acceptable elastic modulus, higher corrosion resistance, and an excellent bioactive response.
Collapse
|
6
|
Yu S, Sun T, Liu W, Yang L, Gong H, Chen X, Li J, Weng J. PLGA Cage‐like Structures Loaded with Sr/Mg‐doped Hydroxyapatite for Repairing Osteoporotic Bone Defects. Macromol Biosci 2022; 22:e2200092. [DOI: 10.1002/mabi.202200092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 04/20/2022] [Indexed: 11/08/2022]
Affiliation(s)
- Shangke Yu
- Key Laboratory of Advanced Technologies of Materials (Ministry of Education) School of Materials Science and Engineering Southwest Jiaotong University Chengdu 610031 China
| | - Tong Sun
- Key Laboratory of Advanced Technologies of Materials (Ministry of Education) School of Materials Science and Engineering Southwest Jiaotong University Chengdu 610031 China
| | - Wei Liu
- Key Laboratory of Advanced Technologies of Materials (Ministry of Education) School of Materials Science and Engineering Southwest Jiaotong University Chengdu 610031 China
| | - Lu Yang
- Key Laboratory of Advanced Technologies of Materials (Ministry of Education) School of Materials Science and Engineering Southwest Jiaotong University Chengdu 610031 China
| | - Hanwen Gong
- College of Medicine Southwest Jiaotong University Chengdu 610031 China
| | - Xingyu Chen
- Key Laboratory of Advanced Technologies of Materials (Ministry of Education) School of Materials Science and Engineering Southwest Jiaotong University Chengdu 610031 China
- College of Medicine Southwest Jiaotong University Chengdu 610031 China
- College of Polymer Science and Engineering State Key Laboratory of Polymer Materials Engineering Sichuan University Chengdu 610065 P.R. China
| | - Jianshu Li
- College of Polymer Science and Engineering State Key Laboratory of Polymer Materials Engineering Sichuan University Chengdu 610065 P.R. China
| | - Jie Weng
- Key Laboratory of Advanced Technologies of Materials (Ministry of Education) School of Materials Science and Engineering Southwest Jiaotong University Chengdu 610031 China
- College of Medicine Southwest Jiaotong University Chengdu 610031 China
| |
Collapse
|
7
|
Radha R, Sreekanth D. Mechanical, in vitro corrosion and bioactivity performance of Mg based composite for orthopedic implant applications: Influence of Sn and HA addition. BIOMEDICAL ENGINEERING ADVANCES 2022. [DOI: 10.1016/j.bea.2022.100033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
8
|
Microstructure Characteristics and Corrosion Behaviors of Mg-2Zn-2Er-0.3Zr-0.3Mn Alloy under Various Rolling Reductions. METALS 2022. [DOI: 10.3390/met12020365] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
The poor corrosion resistance of magnesium alloys is one of the major obstacles to their widespread applications in the engineering field and the medical field. A hot deformation process is the main way to improve the corrosion resistance of magnesium alloys. In the present study, X-ray photoelectron spectroscopy (XPS), a scanning electron microscope (SEM), an electron probe micro-analyzer (EPMA) and X-ray diffraction (XRD) were used to investigate the micro-galvanic corrosion behavior and film protection mechanism of hot-rolled Mg-2Zn-2Er-0.3Zr-0.3Mn under 25%, 50% and 75% thickness reductions in Hank’s solution. The results revealed that the best corrosion resistance was obtained in the alloy under a 75% thickness reduction, with a corrosion rate of 0.85 mm/y. The improvement in anti-corrosion was due to the coupling effect of a refined microstructure and dense degradation film on the large deformation hot-rolled alloy. Furthermore, the elements Mn and Er participated in the film formation and stabilized the film structure.
Collapse
|