1
|
Pirot SM, Omer KM, Alshatteri AH, Ali GK, Shatery OBA. Dual-template molecularly surface imprinted polymer on fluorescent metal-organic frameworks functionalized with carbon dots for ascorbic acid and uric acid detection. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 291:122340. [PMID: 36702082 DOI: 10.1016/j.saa.2023.122340] [Citation(s) in RCA: 36] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Revised: 12/29/2022] [Accepted: 01/06/2023] [Indexed: 06/18/2023]
Abstract
In this work, dual-template molecularly imprinted polymer surfaces imprinted on blue fluorescent Cr-based MOF (Cr-MOF) functionalized with yellow emissive carbon dots (Y-CDs) were prepared using l-ascorbic acid (AA) and uric acid (UA) as templates for simultaneous selective recognition of AA and UA. The as-prepared nanocomposite probe (Y-CDs/Cr-MOF@MIP) contains two recognition site cavities and emits a dual well-resolved fluorescence spectra when excited at 390 nm; blue emission (λem 450 nm) is due to Cr-MOF, and yellow emission (λem 560 nm) is due to Y-CDs. The yellow fluorescence emission of Y-CDs was quenched upon the addition of ascorbic acid, while Cr-MOF's emission remained unaffected. In the same way, the blue fluorescence emission of the Cr-MOFs was quenched in the presence of uric acid, while the yellow emission remained constant. Both emissions were quenched in a sample containing both AA and UA. This can be exploited to design a dual-template biosensor to detect UA and AA simultaneously. The Y-CDs/Cr-MOF@MIP sensor displayed a dynamic linear response for AA in the range 25.0 µM - 425.0 µM with a detection limit of 1.30 µM, and for UA in the range 25.0 µM - 425.0 µM with a detection limit of 1.10 µM. The dual-target probe Y-CDs/Cr-MOF@MIP was highly selective and sensitive for the detection of UA and AA in human urine samples due to the selectivity of the two recognition sites.
Collapse
Affiliation(s)
- Shano M Pirot
- Department of Chemistry, College of Science, University of Sulaimani, Qliasan St,46002, Sulaimani City, Kurdistan Region, Iraq; Center for Biomedical Analysis, Department of Chemistry, College of Science, University of Sulaimani, Qliasan St,46002, Sulaimani City, Kurdistan Region, Iraq
| | - Khalid M Omer
- Department of Chemistry, College of Science, University of Sulaimani, Qliasan St,46002, Sulaimani City, Kurdistan Region, Iraq; Center for Biomedical Analysis, Department of Chemistry, College of Science, University of Sulaimani, Qliasan St,46002, Sulaimani City, Kurdistan Region, Iraq.
| | - Azad H Alshatteri
- Department of Chemistry, College of Science, University of Sulaimani, Qliasan St,46002, Sulaimani City, Kurdistan Region, Iraq; Department of Chemistry, College of Education, University of Garmian, Sulaimaniyah, Kurdistan Region, Iraq
| | - Gona K Ali
- Department of Chemistry, College of Science, University of Sulaimani, Qliasan St,46002, Sulaimani City, Kurdistan Region, Iraq; Center for Biomedical Analysis, Department of Chemistry, College of Science, University of Sulaimani, Qliasan St,46002, Sulaimani City, Kurdistan Region, Iraq
| | - Omer B A Shatery
- Department of Chemistry, College of Science, University of Sulaimani, Qliasan St,46002, Sulaimani City, Kurdistan Region, Iraq; Center for Biomedical Analysis, Department of Chemistry, College of Science, University of Sulaimani, Qliasan St,46002, Sulaimani City, Kurdistan Region, Iraq
| |
Collapse
|
2
|
Alizadeh T, Mousavi Z. Molecularly imprinted polymer specific to creatinine complex with copper(II) ions for voltammetric determination of creatinine. Mikrochim Acta 2022; 189:393. [PMID: 36151400 DOI: 10.1007/s00604-022-05470-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Accepted: 08/19/2022] [Indexed: 05/15/2025]
Abstract
Synthesis of creatinine-imprinted polymer is challenging because of its insolubility in aprotic solvents, traditionally utilized for synthesizing molecularly imprinted polymer (MIP). Moreover, creatinine is not electroactive at conventional electrodes, and thus, introducing an electrochemical sensing platform for its determination is a difficult target. This study addressed the above-cited issues to introduce a novel creatinine voltammetric sensor with high selectivity and sensitivity. Creatinine-copper complex was found to be soluble in acetonitrile and was utilized as a template for the MIP synthesis. Methacrylic acid, ethylene glycol dimethacrylate, and azobisisobutyronitrile were used as functional monomers, cross-linker, and initiator, respectively. The MIP holding creatinine sites were used to modify the carbon paste electrode. Since creatinine did not exhibit a significant voltammetric signal, an indirect sensing technique was employed. This was based on using Cu(II) ion as an electrochemical probe. The MIP-modified electrode signal for copper ion was significantly improved in the presence of creatinine. However, the introduction of creatinine in the Cu(II) solution did not affect the NIP-modified electrode response to copper ion. The proposed sensor indicated a linear current response in the range 1 × 10-7-1 × 10-5 mol L-1 with a detection limit of 5.9 × 10-8 mol L-1 (S/N = 3). Moreover, this method presents excellent performance in real sample analysis, with values of favorable creatinine recovery in plasma. The system exhibits acceptable precision (RSD = 4.04) and favorable selectivity toward creatinine.
Collapse
Affiliation(s)
- Taher Alizadeh
- Department of Analytical Chemistry, Faculty of Chemistry, University College of Science, University of Tehran, P.O. Box 14155-6455, Tehran, Iran.
| | - Zahrasadat Mousavi
- Department of Analytical Chemistry, Faculty of Chemistry, University College of Science, University of Tehran, P.O. Box 14155-6455, Tehran, Iran
| |
Collapse
|
3
|
Preparation of C-Terminal Epitope Imprinted Particles Via Reversible Addition-Fragmentation Chain Transfer Polymerization and Zn2+ Chelating Strategy: Selective Recognition of Cytochrome c. Chromatographia 2022. [DOI: 10.1007/s10337-022-04180-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
4
|
Rakesh Kumar RK, Shaikh MO, Chuang CH. A review of recent advances in non-enzymatic electrochemical creatinine biosensing. Anal Chim Acta 2021; 1183:338748. [PMID: 34627521 DOI: 10.1016/j.aca.2021.338748] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 06/05/2021] [Accepted: 06/07/2021] [Indexed: 01/28/2023]
Abstract
Creatinine biosensing is a rapidly developing field owing to the clinical relevance of creatinine as a vital biomarker for several diseases associated with renal, thyroidal, and muscular dysfunctions. Over the years, we have observed numerous creatinine biosensing strategies, including the most widely studied enzymatic creatinine biosensors. Though the enzymatic approach provides excellent selectivity and reliability, it has certain drawbacks, which include high fabrication cost and poor storage stability (that is inherent to every enzyme-based biosensors). This has led to the development of non-enzymatic creatinine biosensors, of which electrochemical sensors are the most promising for point-of-care applications. However, only a limited number of studies have been conducted and there is a lack of reviews addressing the recent advances in this research area. Herein, we present for the first time, a review with a prime focus on the various strategies implemented in non-enzymatic electrochemical creatinine biosensing. We aim to offer a comprehensive context on the achievements and limitations of currently available non-enzymatic electrochemical creatinine biosensors and address the underlying factors pertaining to the interplay of modification/fabrication techniques with the sensitivity, selectivity, interferences, and long-term storage stability of the biosensor. We hope that this work shall prove to be seminal in the conception and advancement of future non-enzymatic electrochemical creatinine biosensors.
Collapse
Affiliation(s)
- R K Rakesh Kumar
- Institute of Medical Science and Technology, National Sun Yat-sen University, Taiwan
| | | | - Cheng-Hsin Chuang
- Institute of Medical Science and Technology, National Sun Yat-sen University, Taiwan.
| |
Collapse
|
5
|
Mujahid A, Mustafa G, Dickert FL. Label-Free Bioanalyte Detection from Nanometer to Micrometer Dimensions-Molecular Imprinting and QCMs †. BIOSENSORS 2018; 8:E52. [PMID: 29865200 PMCID: PMC6022876 DOI: 10.3390/bios8020052] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Revised: 05/19/2018] [Accepted: 05/21/2018] [Indexed: 12/13/2022]
Abstract
Modern diagnostic tools and immunoassay protocols urges direct analyte recognition based on its intrinsic behavior without using any labeling indicator. This not only improves the detection reliability, but also reduces sample preparation time and complexity involved during labeling step. Label-free biosensor devices are capable of monitoring analyte physiochemical properties such as binding sensitivity and selectivity, affinity constants and other dynamics of molecular recognition. The interface of a typical biosensor could range from natural antibodies to synthetic receptors for example molecular imprinted polymers (MIPs). The foremost advantages of using MIPs are their high binding selectivity comparable to natural antibodies, straightforward synthesis in short time, high thermal/chemical stability and compatibility with different transducers. Quartz crystal microbalance (QCM) resonators are leading acoustic devices that are extensively used for mass-sensitive measurements. Highlight features of QCM devices include low cost fabrication, room temperature operation, and most importantly ability to monitor extremely low mass shifts, thus potentially a universal transducer. The combination of MIPs with quartz QCM has turned out as a prominent sensing system for label-free recognition of diverse bioanalytes. In this article, we shall encompass the potential applications of MIP-QCM sensors exclusively label-free recognition of bacteria and virus species as representative micro and nanosized bioanalytes.
Collapse
Affiliation(s)
- Adnan Mujahid
- Department of Analytical Chemistry, University of Vienna, Währinger Straße 38, A-1090 Vienna, Austria.
- Institute of Chemistry, University of the Punjab, Quaid-i-Azam Campus, Lahore 54590, Pakistan.
| | - Ghulam Mustafa
- Center for Interdisciplinary Research in Basic Sciences, International Islamic University, H-10, Islamabad 44000, Pakistan.
| | - Franz L Dickert
- Department of Analytical Chemistry, University of Vienna, Währinger Straße 38, A-1090 Vienna, Austria.
| |
Collapse
|
6
|
Topçu AA, Bereli N, Albayrak İ, Denizli A. Creatinine imprinted poly(hydroxyethyl methacrylate) based cryogel cartridges. JOURNAL OF MACROMOLECULAR SCIENCE PART A-PURE AND APPLIED CHEMISTRY 2017. [DOI: 10.1080/10601325.2017.1320756] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- Aykut Arif Topçu
- Department of Biology, Kırıkkale University, Kırıkkale, Turkey
- Department of Chemistry, Hacettepe University, Ankara, Turkey
| | - Nilay Bereli
- Department of Chemistry, Hacettepe University, Ankara, Turkey
| | - İrfan Albayrak
- Department of Biology, Kırıkkale University, Kırıkkale, Turkey
| | - Adil Denizli
- Department of Chemistry, Hacettepe University, Ankara, Turkey
| |
Collapse
|
7
|
Morphology and kinetic modeling of molecularly imprinted organosilanol polymer matrix for specific uptake of creatinine. Anal Bioanal Chem 2015; 407:6747-58. [PMID: 26163132 DOI: 10.1007/s00216-015-8841-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2015] [Revised: 06/07/2015] [Accepted: 06/09/2015] [Indexed: 01/25/2023]
Abstract
Molecular imprinting is an emerging technique to create imprinted polymers that can be applied in affinity-based separation, in particular, biomimetic sensors. In this study, the matrix of siloxane bonds prepared from the polycondensation of hydrolyzed tetraethoxysilane (TEOS) was employed as the inorganic monomer for the formation of a creatinine (Cre)-based molecularly imprinted polymer (MIP). Doped aluminium ion (Al(3+)) was used as the functional cross-linker that generated Lewis acid sites in the confined silica matrix to interact with Cre via sharing of lone pair electrons. Surface morphologies and pore characteristics of the synthesized MIP were determined by field emission scanning electron microscopy (FESEM) and Brunauer-Emmet-Teller (BET) analyses, respectively. The imprinting efficiency of MIPs was then evaluated through the adsorption of Cre with regard to molar ratios of Al(3+). A Cre adsorption capacity of up to 17.40 mg Cre g(-1) MIP was obtained and adsorption selectivity of Cre to its analogues creatine (Cr) and N-hydroxysuccinimide (N-hyd) were found to be 3.90 ± 0.61 and 4.17 ± 3.09, respectively. Of all the studied MIP systems, chemisorption was predicted as the rate-limiting step in the binding of Cre. The pseudo-second-order chemical reaction kinetic provides the best correlation of the experimental data. Furthermore, the equilibrium adsorption capacity of MIP fit well with a Freundlich isotherm (R (2) = 0.98) in which the heterogeneous surface was defined.
Collapse
|
8
|
Cheng Y, Jiang P, Dong X. Molecularly imprinted fluorescent chemosensor synthesized using quinoline-modified-β-cyclodextrin as monomer for spermidine recognition. RSC Adv 2015. [DOI: 10.1039/c5ra07761c] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Preparation of imprinted fluorescent chemosensor using quinoline-modified-β-cyclodextrin as monomer for spermidine recognition.
Collapse
Affiliation(s)
- Yang Cheng
- College of Chemistry
- Nankai University
- Tianjin 300071
- China
- Collaborative Innovation Center of Chemical Science and Engineering (Tianjin)
| | - Ping Jiang
- College of Chemistry
- Nankai University
- Tianjin 300071
- China
| | - Xiangchao Dong
- College of Chemistry
- Nankai University
- Tianjin 300071
- China
- Collaborative Innovation Center of Chemical Science and Engineering (Tianjin)
| |
Collapse
|
9
|
MIPs in Aqueous Environments. MOLECULARLY IMPRINTED POLYMERS IN BIOTECHNOLOGY 2015; 150:131-66. [DOI: 10.1007/10_2015_317] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/10/2023]
|
10
|
Whitcombe MJ, Kirsch N, Nicholls IA. Molecular imprinting science and technology: a survey of the literature for the years 2004-2011. J Mol Recognit 2014; 27:297-401. [PMID: 24700625 DOI: 10.1002/jmr.2347] [Citation(s) in RCA: 279] [Impact Index Per Article: 25.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2013] [Revised: 10/28/2013] [Accepted: 12/01/2013] [Indexed: 12/11/2022]
Abstract
Herein, we present a survey of the literature covering the development of molecular imprinting science and technology over the years 2004-2011. In total, 3779 references to the original papers, reviews, edited volumes and monographs from this period are included, along with recently identified uncited materials from prior to 2004, which were omitted in the first instalment of this series covering the years 1930-2003. In the presentation of the assembled references, a section presenting reviews and monographs covering the area is followed by sections describing fundamental aspects of molecular imprinting including the development of novel polymer formats. Thereafter, literature describing efforts to apply these polymeric materials to a range of application areas is presented. Current trends and areas of rapid development are discussed.
Collapse
|
11
|
Kozitsina AN, Dedeneva SS, Shalygina ZV, Okhokhonin AV, Chizhov DL, Matern AI, Brainina KZ. Determination of urea and creatinine by chronoamperometry. JOURNAL OF ANALYTICAL CHEMISTRY 2014. [DOI: 10.1134/s1061934814080048] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
12
|
Zhang H. Water-compatible molecularly imprinted polymers: Promising synthetic substitutes for biological receptors. POLYMER 2014. [DOI: 10.1016/j.polymer.2013.12.064] [Citation(s) in RCA: 92] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
13
|
Sergeyeva T, Gorbach L, Piletska E, Piletsky S, Brovko O, Honcharova L, Lutsyk O, Sergeeva L, Zinchenko O, El'skaya A. Colorimetric test-systems for creatinine detection based on composite molecularly imprinted polymer membranes. Anal Chim Acta 2013; 770:161-8. [DOI: 10.1016/j.aca.2013.01.048] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2012] [Revised: 01/17/2013] [Accepted: 01/24/2013] [Indexed: 10/27/2022]
|
14
|
Morais EC, Correa GG, Brambilla R, dos Santos JHZ, Fisch AG. Selective silica-based sorbent materials synthesized by molecular imprinting for adsorption of pharmaceuticals in aqueous matrices. J Sep Sci 2013; 36:636-43. [DOI: 10.1002/jssc.201200774] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2012] [Revised: 10/17/2012] [Accepted: 10/17/2012] [Indexed: 11/07/2022]
|
15
|
A review on creatinine measurement techniques. Talanta 2012; 97:1-8. [DOI: 10.1016/j.talanta.2012.04.005] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2011] [Revised: 03/10/2012] [Accepted: 04/01/2012] [Indexed: 11/22/2022]
|
16
|
HAGINAKA J, MIURA C, FUNAYA N, MATSUNAGA H. Monodispersed Molecularly Imprinted Polymer for Creatinine by Modified Precipitation Polymerization. ANAL SCI 2012; 28:315-7. [DOI: 10.2116/analsci.28.315] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Jun HAGINAKA
- School of Pharmacy & Pharmaceutical Sciences, Mukogawa Women’s University
| | - Chitose MIURA
- School of Pharmacy & Pharmaceutical Sciences, Mukogawa Women’s University
| | - Noriko FUNAYA
- School of Pharmacy & Pharmaceutical Sciences, Mukogawa Women’s University
| | - Hisami MATSUNAGA
- School of Pharmacy & Pharmaceutical Sciences, Mukogawa Women’s University
| |
Collapse
|
17
|
Li TJ, Chen PY, Nien PC, Lin CY, Vittal R, Ling TR, Ho KC. Preparation of a novel molecularly imprinted polymer by the sol–gel process for sensing creatinine. Anal Chim Acta 2012; 711:83-90. [PMID: 22152800 DOI: 10.1016/j.aca.2011.10.031] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2011] [Revised: 10/14/2011] [Accepted: 10/17/2011] [Indexed: 11/24/2022]
|
18
|
Substitution of Antibody with Molecularly Imprinted Film in Enzyme-Linked Immunosorbent Assay for Determination of Trace Ractopamine in Urine and Pork Samples. FOOD ANAL METHOD 2011. [DOI: 10.1007/s12161-011-9206-4] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
19
|
Sun ZY, Shen MX, Yang AW, Liang CQ, Wang N, Cao GP. Introduction of β-cyclodextrin into poly(aspartic acid) matrix for adsorption and time-release of ibuprofen. Chem Commun (Camb) 2011; 47:1072-4. [DOI: 10.1039/c0cc03492d] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
20
|
Syu MJ, Hsu TJ, Lin ZK. Synthesis of Recognition Matrix from 4-Methylamino-N-Allylnaphthal-Imide with Fluorescent Effect for the Imprinting of Creatinine. Anal Chem 2010; 82:8821-9. [DOI: 10.1021/ac1011848] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Mei-Jywan Syu
- Department of Chemical Engineering, National Cheng Kung University, Tainan, Taiwan 701
| | - Ting-Jung Hsu
- Department of Chemical Engineering, National Cheng Kung University, Tainan, Taiwan 701
| | - Zong-Kun Lin
- Department of Chemical Engineering, National Cheng Kung University, Tainan, Taiwan 701
| |
Collapse
|
21
|
Preparation and recognition performance of creatinine-imprinted material prepared with novel surface-imprinting technique. J Chromatogr B Analyt Technol Biomed Life Sci 2010; 878:2077-86. [DOI: 10.1016/j.jchromb.2010.06.007] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2010] [Revised: 06/03/2010] [Accepted: 06/03/2010] [Indexed: 11/24/2022]
|
22
|
Sun ZY, Shen MX, Cao GP, Deng J, Liu Y, Liu T, Zhao L, Yuan WK. Preparation of bimodal porous copolymer containing β-cyclodextrin and its inclusion adsorption behavior. J Appl Polym Sci 2010. [DOI: 10.1002/app.32515] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
23
|
Sun ZY, Cao GP, Lv H, Zhao L, Liu T, Montastruc L, Iordan N. Equilibrium of benzidine inclusion adsorption on cyclodextrin copolymer. J Appl Polym Sci 2009. [DOI: 10.1002/app.30017] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
24
|
Kareuhanon W, Lee VS, Nimmanpipug P, Tayapiwatana C, Pattarawarapan M. Synthesis of Molecularly Imprinted Polymers for Nevirapine by Dummy Template Imprinting Approach. Chromatographia 2009. [DOI: 10.1365/s10337-009-1385-4] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
25
|
Li Y, Li X, Li Y, Dong C, Jin P, Qi J. Selective recognition of veterinary drugs residues by artificial antibodies designed using a computational approach. Biomaterials 2009; 30:3205-11. [PMID: 19345994 DOI: 10.1016/j.biomaterials.2009.03.007] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2009] [Accepted: 03/07/2009] [Indexed: 11/15/2022]
Abstract
In this work we introduce a simple and inexpensive veterinary drugs residues detection method. Molecular dynamics simulations and computational screening were used to identify functional monomers capable of interacting with sulfadimidine (SM2). A library of 15 kinds of common functional monomers for preparing molecular imprinted polymer (MIP) was built and their interactions with SM2 in acetonitrile were calculated using the molecular dynamics software (GROMACS 3.3). According to the theoretical calculation results, the surface molecularly imprinted silica (MIP-silica) with SM2 as template was prepared by surface-imprinting technique using methacrylic acid (MAA) as functional monomer and divinylbenzene as cross-linker in acetonitrile. The surface composition of the MIP-silica was determined by Fourier transform infrared spectrometer (FT-IR) and energy dispersive X-ray spectrometer (EDS). Scanning electron microscopy (SEM) was used to characterize the morphological properties of the MIP-silica. The synthesized MIP-silica was then tested by equilibrium-adsorption method, and the MIP-silica demonstrated high binding specificity to the SM2. The molecular recognition of SM2 was analyzed in detail by using molecular modeling software (Gaussian 03).
Collapse
Affiliation(s)
- Yuqi Li
- Department of Chemistry, Harbin Institute of Technology, Harbin 150090, China
| | | | | | | | | | | |
Collapse
|
26
|
Chang YS, Ko TH, Hsu TJ, Syu MJ. Synthesis of an Imprinted Hybrid Organic−Inorganic Polymeric Sol−Gel Matrix Toward the Specific Binding and Isotherm Kinetics Investigation of Creatinine. Anal Chem 2009; 81:2098-105. [DOI: 10.1021/ac802168w] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Affiliation(s)
- Yong-Sheun Chang
- Department of Chemical Engineering, National Cheng Kung University, Tainan, Taiwan 70101
| | - Ting-Hsien Ko
- Department of Chemical Engineering, National Cheng Kung University, Tainan, Taiwan 70101
| | - Ting-Jung Hsu
- Department of Chemical Engineering, National Cheng Kung University, Tainan, Taiwan 70101
| | - Mei-Jywan Syu
- Department of Chemical Engineering, National Cheng Kung University, Tainan, Taiwan 70101
| |
Collapse
|
27
|
Yao Q, Zhou Y. Surface Functional Imprinting of Bensulfuron-methyl at Surface of Silica Nanoparticles Linked by Silane Coupling Agent. J Inorg Organomet Polym Mater 2009. [DOI: 10.1007/s10904-009-9253-0] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
28
|
Fraczyk J, Kaminski ZJ. Design, Synthesis, and Application of a Library of Supramolecular Structures Formed by N-Lipidated Peptides Immobilized on Cellulose. Artificial Receptors. ACTA ACUST UNITED AC 2008; 10:934-40. [DOI: 10.1021/cc800114n] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Justyna Fraczyk
- Institute of Organic Chemistry, Technical University of Lodz, Żeromskiego 116, 90-924 Lodz, Poland
| | - Zbigniew J. Kaminski
- Institute of Organic Chemistry, Technical University of Lodz, Żeromskiego 116, 90-924 Lodz, Poland
| |
Collapse
|
29
|
Lakshmi D, Sharma PS, Prasad BB. Imprinted polymer-modified hanging mercury drop electrode for differential pulse cathodic stripping voltammetric analysis of creatine. Biosens Bioelectron 2007; 22:3302-8. [PMID: 17208426 DOI: 10.1016/j.bios.2006.12.011] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2006] [Revised: 11/25/2006] [Accepted: 12/04/2006] [Indexed: 10/23/2022]
Abstract
The molecularly imprinted polymer [poly(p-aminobenzoicacid-co-1,2-dichloroethane)] film casting was made on the surface of a hanging mercury drop electrode by drop-coating method for the selective and sensitive evaluation of creatine in water, blood serum and pharmaceutical samples. The molecular recognition of creatine by the imprinted polymer was found to be specific via non-covalent (electrostatic) imprinting. The creatine binding could easily be detected by differential pulse, cathodic stripping voltammetric signal at optimised operational conditions: accumulation potential -0.01 V (versus Ag/AgCl), polymer deposition time 15s, template accumulation time 60s, pH 7.1 (supporting electrolyte< or =5 x 10(-4)M NaOH), scan rate 10 mV s(-1), pulse amplitude 25 mV. The modified sensor in the present study was found to be highly reproducible and selective with detection limit 0.11 ng mL(-1) of creatine. Cross-reactivity studies revealed no response to the addition of urea, creatinine and phenylalanine; however, some insignificant magnitude of current was observed for tryptophan and histidine in the test samples.
Collapse
Affiliation(s)
- Dhana Lakshmi
- Analytical Division, Department of Chemistry, Faculty of Science, Banaras Hindu University, Varanasi 221005, India
| | | | | |
Collapse
|
30
|
Sharma PS, Lakshmi D, Prasad BB. Highly Sensitive and Selective Detection of Creatinine by Combined Use of MISPE and a Complementary MIP-Sensor. Chromatographia 2007. [DOI: 10.1365/s10337-007-0172-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
31
|
da Costa Silva RG, Augusto F. Sol–gel molecular imprinted ormosil for solid-phase extraction of methylxanthines. J Chromatogr A 2006; 1114:216-23. [PMID: 16616927 DOI: 10.1016/j.chroma.2006.03.073] [Citation(s) in RCA: 87] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2005] [Revised: 03/20/2006] [Accepted: 03/22/2006] [Indexed: 11/25/2022]
Abstract
A organically modified molecularly imprinted silica (MIS), selective for methylxanthines, was prepared using a simple sol-gel procedure. Caffeine was used as template; 3-aminopropyltrimethoxysilane (APTMS) as functional monomer and tetraethyl orthosilicate (TEOS) as reticulating agent. The material was packed on solid-phase extraction (SPE) cartridges and evaluated with aqueous test samples, natural water and human urine; a quantitative method for methylxanthines in water, using SPE cartridges packed with the MIS coupled with HPLC-UV was developed. The MIS was highly specific for methylxanthines, with an imprinting factor of (20.5+/-1.9). The analytical method resulted in detection limits of 85 microgL(-1) for theobromine, 44 microgL(-1) for theophylline and 53 microgL(-1) for caffeine.
Collapse
Affiliation(s)
- Raquel Gomes da Costa Silva
- Institute of Chemistry, Campinas State University (Unicamp), CP 6154 - 13084-971 Campinas, São Paulo, Brazil
| | | |
Collapse
|