1
|
Wang B, Xia J, Zhou G, Li X, Dai M, Jiang D, Li Q. Tb(iii)-doped nanosheets as a fluorescent probe for the detection of dipicolinic acid. RSC Adv 2020; 10:37500-37506. [PMID: 35521243 PMCID: PMC9057155 DOI: 10.1039/c9ra09695g] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Accepted: 10/01/2020] [Indexed: 01/04/2023] Open
Abstract
A new fluorescent probe based on terbium(iii)-doped nanosheets was designed for detecting low-levels of dipicolinic acid (DPA), a biomarker of bacterial spores. The ability to detect ultra-low concentrations of DPA is therefore of great significance. First, Tb(iii)-doped ytterbium hydroxide nanosheets were obtained by mechanical exfoliation from layered rare-earth hydroxide (LRH) materials. The morphology of the as-synthesized nanosheets was studied by transmission electron microscopy and atomic force microscopy. The Tb(iii)-doped nanosheets are demonstrated to be highly sensitive to DPA, which remarkably enhances Tb(iii) luminescence intensities at a wavelength of 544 nm. Furthermore, Tb(iii) emission increases linearly with DPA concentration. Selectivity studies were conducted by adding different competing aromatic ligands to the sensing solution; however, their fluorescence responses were observed to be negligibly small in comparison with that of DPA. Our findings provide a basis for the application of Tb(iii)-doped nanosheets for accurate, sensitive, and selective monitoring of DPA as a biomarker of anthrax.
Collapse
Affiliation(s)
- Bing Wang
- School of Chemistry and Molecular Engineering, East China Normal University Shanghai 200062 P. R. China
| | - Jinfeng Xia
- Shanghai Institute of Ceramics, Chinese Academy of Sciences Shanghai 200050 P. R. China
| | - Guohong Zhou
- Shanghai Institute of Ceramics, Chinese Academy of Sciences Shanghai 200050 P. R. China
| | - Xin Li
- School of Chemistry and Molecular Engineering, East China Normal University Shanghai 200062 P. R. China
| | - Mengting Dai
- School of Chemistry and Molecular Engineering, East China Normal University Shanghai 200062 P. R. China
| | - Danyu Jiang
- Shanghai Institute of Ceramics, Chinese Academy of Sciences Shanghai 200050 P. R. China
| | - Qiang Li
- School of Chemistry and Molecular Engineering, East China Normal University Shanghai 200062 P. R. China
| |
Collapse
|
2
|
Abstract
Barcoded bioassays are ready to promote bioanalysis and biomedicine toward the point of care.
Collapse
Affiliation(s)
- Mingzhu Yang
- Beijing Engineering Research Center for BioNanotechnology
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety
- CAS Center for Excellence in Nanoscience
- National Center for NanoScience and Technology
- Beijing
| | - Yong Liu
- Beijing Engineering Research Center for BioNanotechnology
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety
- CAS Center for Excellence in Nanoscience
- National Center for NanoScience and Technology
- Beijing
| | - Xingyu Jiang
- Beijing Engineering Research Center for BioNanotechnology
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety
- CAS Center for Excellence in Nanoscience
- National Center for NanoScience and Technology
- Beijing
| |
Collapse
|
3
|
Broto M, Galve R, Marco MP. Sandwich NP-based biobarcode assay for quantification C-reactive protein in plasma samples. Anal Chim Acta 2017; 992:112-118. [PMID: 29054144 DOI: 10.1016/j.aca.2017.09.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Revised: 08/29/2017] [Accepted: 09/01/2017] [Indexed: 12/20/2022]
Abstract
A NP-based biobarcode for C-reactive protein (CRP) quantification in plasma samples is reported for the first time. The assay uses capture antibody functionalized magnetic beads (pAbCRP2-MP), multifunctional oligonucleotide encoded probes modified with a detection antibody (pAbCRP1-ePSP), and a fluorescent DNA microarray. Thus, magnetic beads are added to the sample to form immunocomplexes that will be isolated, to then add the codified particles to form a sandwich complex with both particles and the target protein, subsequently the complexes are treated to release the oligonucleotide codes, which are finally hybridized in a fluorescent DNA microarray. The assay has been implemented to the analysis of plasma samples being able to quantify this biomarker within 900 ng mL-1 to 12500 ng mL-1 with an excellent accuracy (mean of recovery of 99.5 ± 4.2%, N = 3). The CRP biobarcode has been used on a small pilot clinical study in which plasma samples from patients suffering different pathologies, most of them related to cardiovascular diseases (CVDs). The samples have been analyzed and the results compared to a reference method demonstrating that the assay can be useful for monitoring this biomarker on patients being suspicious to be under risk of suffering CVDs or other diseases involving inflammatory processes.
Collapse
Affiliation(s)
- Marta Broto
- Nanobiotechnology for Diagnostics (Nb4D), Department of Chemical and Biomolecular Nanotechnology, Institute for Advanced Chemistry of Catalonia (IQAC) of the Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, 08034 Barcelona, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034 Barcelona, Spain
| | - Roger Galve
- Nanobiotechnology for Diagnostics (Nb4D), Department of Chemical and Biomolecular Nanotechnology, Institute for Advanced Chemistry of Catalonia (IQAC) of the Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, 08034 Barcelona, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034 Barcelona, Spain.
| | - M-Pilar Marco
- Nanobiotechnology for Diagnostics (Nb4D), Department of Chemical and Biomolecular Nanotechnology, Institute for Advanced Chemistry of Catalonia (IQAC) of the Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, 08034 Barcelona, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034 Barcelona, Spain
| |
Collapse
|
4
|
Broto M, Salvador JP, Galve R, Marco MP. Biobarcode assay for the oral anticoagulant acenocoumarol. Talanta 2017; 178:308-314. [PMID: 29136827 DOI: 10.1016/j.talanta.2017.09.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Revised: 08/29/2017] [Accepted: 09/02/2017] [Indexed: 12/28/2022]
Abstract
A novel approach for therapeutic drug monitoring of oral anticoagulants (OA) in clinical samples is reported, based on a NP-based biobarcode assay. The proposed strategy uses specific antibodies for acenocumarol (ACL) covalently bound to magnetic particles (pAb236-MP) and a bioconjugate competitor (hACL-BSA) linked to encoded polystyrene probes (hACL-BSA-ePSP) on a classical competitive immunochemical format. By using this scheme ACL can be detected in low nM range (LOD, 0.96 ± 0.26, N = 3, in buffer) even in complex samples such as serum or plasma (LOD 4 ± 1). The assay shows a high reproducibility (%CV 1.1 day-to-day) and is robust, as it is demonstrated by the fact that ACL can be quantified in complex biological samples with a very good accuracy (slope = 0.97 and R2 = 0.91, of the linear regression obtained when analyzing spiked vs measured values). Moreover, we have demonstrated that the biobarcode approach has the potential to overcome one of the main challenges of the multiplexed diagnostic, which is the possibility to measure in a single run biomarker targets present at different concentration ranges. Thus, it has been proven that the signal and the detectability can be modulated by just modifying the oligonucleotide load of the encoded probes. This fact opens the door for combining in the same assay encoded probes with the necessary oligonucleotide load to achieve the detectability required for each biomarker target.
Collapse
Affiliation(s)
- Marta Broto
- Nanobiotechnology for Diagnostics (Nb4D), Institute for Advanced Chemistry of Catalonia of the Spanish Council for Scientific Research (IQAC-CSIC), Jordi Girona 18-26, 08034 Barcelona, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034 Barcelona, Spain
| | - J Pablo Salvador
- Nanobiotechnology for Diagnostics (Nb4D), Institute for Advanced Chemistry of Catalonia of the Spanish Council for Scientific Research (IQAC-CSIC), Jordi Girona 18-26, 08034 Barcelona, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034 Barcelona, Spain
| | - Roger Galve
- Nanobiotechnology for Diagnostics (Nb4D), Institute for Advanced Chemistry of Catalonia of the Spanish Council for Scientific Research (IQAC-CSIC), Jordi Girona 18-26, 08034 Barcelona, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034 Barcelona, Spain.
| | - M Pilar Marco
- Nanobiotechnology for Diagnostics (Nb4D), Institute for Advanced Chemistry of Catalonia of the Spanish Council for Scientific Research (IQAC-CSIC), Jordi Girona 18-26, 08034 Barcelona, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034 Barcelona, Spain
| |
Collapse
|
5
|
Lee JW, Lee D, Kim YT, Lee EY, Kim DH, Seo TS. Low-cost and facile fabrication of a paper-based capillary electrophoresis microdevice for pathogen detection. Biosens Bioelectron 2017; 91:388-392. [DOI: 10.1016/j.bios.2016.12.053] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2016] [Revised: 12/20/2016] [Accepted: 12/23/2016] [Indexed: 11/26/2022]
|
6
|
Pratush A, Zhang Q, Cao YR, Zhang LX, Li GQ, Liu XP, Li J, Jahan S, Cong F, Xiao H, Fan LY, Cao CX. A simple, openable and electroosmotic flow-free PMMA chip for electrophoretic titration of moving reaction boundary. Microchem J 2017. [DOI: 10.1016/j.microc.2016.12.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
7
|
Lian DS, Zhao SJ. Capillary electrophoresis based on nucleic acid detection for diagnosing human infectious disease. Clin Chem Lab Med 2017; 54:707-38. [PMID: 26352354 DOI: 10.1515/cclm-2015-0096] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2015] [Accepted: 06/17/2015] [Indexed: 01/22/2023]
Abstract
Rapid transmission, high morbidity, and mortality are the features of human infectious diseases caused by microorganisms, such as bacteria, fungi, and viruses. These diseases may lead within a short period of time to great personal and property losses, especially in regions where sanitation is poor. Thus, rapid diagnoses are vital for the prevention and therapeutic intervention of human infectious diseases. Several conventional methods are often used to diagnose infectious diseases, e.g. methods based on cultures or morphology, or biochemical tests based on metabonomics. Although traditional methods are considered gold standards and are used most frequently, they are laborious, time consuming, and tedious and cannot meet the demand for rapid diagnoses. Disease diagnosis using capillary electrophoresis methods has the advantages of high efficiency, high throughput, and high speed, and coupled with the different nucleic acid detection strategies overcomes the drawbacks of traditional identification methods, precluding many types of false positive and negative results. Therefore, this review focuses on the application of capillary electrophoresis based on nucleic detection to the diagnosis of human infectious diseases, and offers an introduction to the limitations, advantages, and future developments of this approach.
Collapse
|
8
|
Moro L, Turemis M, Marini B, Ippodrino R, Giardi MT. Better together: Strategies based on magnetic particles and quantum dots for improved biosensing. Biotechnol Adv 2017; 35:51-63. [DOI: 10.1016/j.biotechadv.2016.11.007] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 09/29/2016] [Accepted: 11/27/2016] [Indexed: 12/14/2022]
|
9
|
Lai XH, Zhao LF, Chen XM, Ren Y. Rapid Identification and Characterization of Francisella by Molecular Biology and Other Techniques. Open Microbiol J 2016; 10:64-77. [PMID: 27335619 PMCID: PMC4899538 DOI: 10.2174/1874285801610010064] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2015] [Revised: 10/20/2015] [Accepted: 10/22/2015] [Indexed: 11/22/2022] Open
Abstract
Francisella tularensis is the causative pathogen of tularemia and a
Tier 1 bioterror agent on the CDC list. Considering the fact that some
subpopulation of the F. tularensis strains is more virulent, more
significantly associated with mortality, and therefore poses more threat to
humans, rapid identification and characterization of this subpopulation strains
is of invaluable importance. This review summarizes the up-to-date developments
of assays for mainly detecting and characterizing F. tularensis and a
touch of caveats of some of the assays.
Collapse
Affiliation(s)
- Xin-He Lai
- Institute of Inflammation & Diseases, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China; Institute of Translational Medicine, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Long-Fei Zhao
- College of Life Sciences, Key Laboratory of Plant-Microbe Interactions of Henan, Shangqiu Normal University, Shangqiu, Henan, 476000, PR China
| | - Xiao-Ming Chen
- Institute of Inflammation & Diseases, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China; Institute of Translational Medicine, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China ; Department of Pediatric Surgery, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Yi Ren
- Institute of Inflammation & Diseases, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China; Department of Biomedical Sciences, Florida State University College of Medicine, Tallahassee, FL, USA
| |
Collapse
|
10
|
Cho M, Chung S, Kim YT, Jung JH, Kim DH, Seo TS. A fully integrated microdevice for biobarcode assay based biological agent detection. LAB ON A CHIP 2015; 15:2744-2748. [PMID: 26032690 DOI: 10.1039/c5lc00355e] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
An integrated microdevice, consisting of a micropump, a passive mixer, a magnetic separation chamber, and a microcapillary electrophoretic channel, was constructed for biobarcode assay based multiplex biological agent detection in a sample-to-answer-out manner within 30 min with high sensitivity.
Collapse
Affiliation(s)
- Minkyung Cho
- Department of Chemical and Biomolecular Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 305-701, Republic of Korea.
| | | | | | | | | | | |
Collapse
|