1
|
Asl SK, Rahimzadegan M. The recent progress in the early diagnosis of acute myocardial infarction based on myoglobin biomarker; nano-aptasensors approaches. J Pharm Biomed Anal 2022; 211:114624. [DOI: 10.1016/j.jpba.2022.114624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Revised: 01/24/2022] [Accepted: 01/25/2022] [Indexed: 10/19/2022]
|
2
|
Modeling Hypoxic Stress In Vitro Using Human Embryonic Stem Cells Derived Cardiomyocytes Matured by FGF4 and Ascorbic Acid Treatment. Cells 2021; 10:cells10102741. [PMID: 34685725 PMCID: PMC8534799 DOI: 10.3390/cells10102741] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 10/08/2021] [Accepted: 10/11/2021] [Indexed: 11/23/2022] Open
Abstract
Mature cardiomyocytes (CMs) obtained from human pluripotent stem cells (hPSCs) have been required for more accurate in vitro modeling of adult-onset cardiac disease and drug discovery. Here, we found that FGF4 and ascorbic acid (AA) induce differentiation of BG01 human embryonic stem cell–cardiogenic mesoderm cells (hESC-CMCs) into mature and ventricular CMs. Co-treatment of BG01 hESC-CMCs with FGF4+AA synergistically induced differentiation into mature and ventricular CMs. FGF4+AA-treated BG01 hESC-CMs robustly released acute myocardial infarction (AMI) biomarkers (cTnI, CK-MB, and myoglobin) into culture medium in response to hypoxic injury. Hypoxia-responsive genes and potential cardiac biomarkers proved in the diagnosis and prognosis of coronary artery diseases were induced in FGF4+AA-treated BG01 hESC-CMs in response to hypoxia based on transcriptome analyses. This study demonstrates that it is feasible to model hypoxic stress in vitro using hESC-CMs matured by soluble factors.
Collapse
|
3
|
Fercher C, Jones ML, Mahler SM, Corrie SR. Recombinant Antibody Engineering Enables Reversible Binding for Continuous Protein Biosensing. ACS Sens 2021; 6:764-776. [PMID: 33481587 DOI: 10.1021/acssensors.0c01510] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Engineering antibodies to improve target specificity, reduce detection limits, or introduce novel functionality is an important research area for biosensor development. While various affinity biosensors have been developed to generate an output signal upon varying analyte concentrations, reversible and continuous protein monitoring in complex biological samples remains challenging. Herein, we explore the concept of directed evolution to modulate dissociation kinetics of a high affinity anti-epidermal growth factor receptor (EGFR) single-chain variable antibody fragment (scFv) to enable continuous protein sensing in a label-free binding assay. A mutant scFv library was generated from the wild type (WT) fragment via targeted permutation of four residues in the antibody-antigen-binding interface. A single round of phage display biopanning complemented with high-throughput screening methods then permitted isolation of a specific binder with fast reaction kinetics. We were able to obtain ∼30 times faster dissociation rates when compared to the WT without appreciably affecting overall affinity and specificity by targeting a single paratope that is known to contribute to the binding interaction. Suitability of a resulting mutant fragment to sense varying antigen concentrations in continuous mode was demonstrated in a modified label-free binding assay, achieving low nanomolar detection limits (KD = 8.39 nM). We also confirmed these results using an independent detection mechanism developed previously by our group, incorporating a polarity-dependent fluorescent dye into the scFv and reading out EGFR binding based on fluorescence wavelength shifts. In future, this generic approach could be employed to generate improved or novel binders for proteins of interest, ready for deployment in a broad range of assay platforms.
Collapse
Affiliation(s)
- Christian Fercher
- Australian Institute for Bioengineering and Nanotechnology, ARC Training Centre for Biopharmaceutical Innovation, The University of Queensland, St. Lucia, Queensland, 4072 Australia
- Australian Institute for Bioengineering and Nanotechnology, ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, The University of Queensland, St. Lucia, Queensland, 4072 Australia
| | - Martina L. Jones
- Australian Institute for Bioengineering and Nanotechnology, ARC Training Centre for Biopharmaceutical Innovation, The University of Queensland, St. Lucia, Queensland, 4072 Australia
| | - Stephen M. Mahler
- Australian Institute for Bioengineering and Nanotechnology, ARC Training Centre for Biopharmaceutical Innovation, The University of Queensland, St. Lucia, Queensland, 4072 Australia
| | - Simon R. Corrie
- Department of Chemical Engineering, ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash University, Clayton, Victoria 3800 Australia
| |
Collapse
|
4
|
Normal-incidence type solution immersed silicon (SIS) biosensor for ultra-sensitive, label-free detection of cardiac troponin I. Biosens Bioelectron 2020; 168:112525. [PMID: 32858415 DOI: 10.1016/j.bios.2020.112525] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 08/14/2020] [Accepted: 08/17/2020] [Indexed: 01/25/2023]
Abstract
Early diagnosis of acute myocardial infarction (AMI) significantly reduce the mortality rate and can be achieved via high-sensitive detection of AMI specific cardiac troponin I (cTnI) biomarker. Here, we present normal-incident type solution-immersed silicon (NI-SIS) ellipsometric biosensor, designed for ultra-high sensitive, high-throughput, label-free detection of the target protein. The NI-SIS sensors are equipped with a specially designed prism that maintains the angle of incidence close to the Brewster angle during operation, which significantly reduces SIS noise signals induced by the refractive index fluctuations of the surrounding medium, improves the signal-to-noise ratio, in-results lowers the detection limit. We applied NI-SIS biosensor for ultra-sensitive detection of cTnI biomarkers in human serum. The optimized sensor chip fabrication and detection operation procedures are proposed. The wide linear concentration ranges of fg/mL to ng/mL is achieved with the detection limit of 22.0 fg/mL of cTnI. The analytical correlation was assessed by linear regression analysis with the results of the Pathfast reference system. These impressive biosensing capabilities of NI-SIS technology have huge potentials for accurate detection of target species in different application areas, such as diagnosis, drug discovery, and food contaminations.
Collapse
|
5
|
Real-time Monitoring of Biomarkers in Serum for Early Diagnosis of Target Disease. BIOCHIP JOURNAL 2020. [DOI: 10.1007/s13206-020-4102-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
6
|
PAS1-modified optical SIS sensor for highly sensitive and specific detection of toluene. Biosens Bioelectron 2019; 141:111469. [PMID: 31260905 DOI: 10.1016/j.bios.2019.111469] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 06/18/2019] [Accepted: 06/22/2019] [Indexed: 11/23/2022]
Abstract
We report on a novel solution immersed silicon (SIS) sensor modified with bio-receptor to detect toluene. To perform this approach, bio-receptor PAS1 which specifically interacts with toluene was chosen as a capture agent for SIS ellipsometric sensing. We constructed wild PAS1 and mutant PAS1 (F46A and F79Y) which are toluene binding-defective. Especially, we utilized an easily accessible capturing approach based on silica binding peptide (SBP) for direct immobilization of PAS1 on the SiO2 surfaces. After the immobilization of SBP-tagged PAS1 to the sensing layers, PAS1-based SIS sensor was evaluated for its ability to recognize toluene. As a result, a significant up-shift in Psi (Ψ) was clearly observed with a low limit of detection (LOD) of 0.1 μM, when treated with toluene on wild PAS1-surface, but not on mutant PAS1-sensing layers, indicating the selective interactions between PAS1 and toluene molecule. The PAS1-SIS sensor showed no changes in Psi (Ψ), if any, negligible, when exposed to benzene, phenol, xylene and 4-nitrophenol as negative controls, thereby demonstrating the specificity of interaction between PAS1 and toluene. Taken together, our results strongly indicate that PAS1-modified ellipsometry sensor can provide a high fidelity system for the accurate and selective detection of toluene.
Collapse
|
7
|
Sameiyan E, Bagheri E, Ramezani M, Alibolandi M, Abnous K, Taghdisi SM. DNA origami-based aptasensors. Biosens Bioelectron 2019; 143:111662. [PMID: 31491726 DOI: 10.1016/j.bios.2019.111662] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 08/26/2019] [Accepted: 08/27/2019] [Indexed: 12/27/2022]
Abstract
Traditional analytical techniques face many limitations such as time-consuming process, complicated sample preparation, high consumption of reagents and need for expensive equipment. So, it is important that simple, rapid and sensitive detection methods are introduced. Nucleic acids-based assays, particularly aptamers, have a great impact on modern life sciences for biological analysis and target detection. Aptamer-based biosensors with unique recognition properties including high specificity and affinity, rapid response and simple fabrication have attracted much attention. It is believed that two- and three-dimensional structures, sometimes referred to as DNA origami, using DNA aptamers can show more selective binding affinity and better stability over other nucleic acids forms. In this review, we will focus on recent advances in the development and uses of electrochemical and optical DNA origami-based aptasensors to supply readers with a comprehensive understanding of their improvements. Also, the challenges and awards of these approaches are discussed.
Collapse
Affiliation(s)
- Elham Sameiyan
- Department of Pharmaceutical Biotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Elnaz Bagheri
- Department of Pharmaceutical Biotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran; Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mohammad Ramezani
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mona Alibolandi
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Khalil Abnous
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Medicinal Chemistry, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran.
| | - Seyed Mohammad Taghdisi
- Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran.
| |
Collapse
|
8
|
Zou B, Cheng H, Tu Y. An electrochemiluminescence immunosensor for myoglobin using an indium tin oxide glass electrode modified with gold nanoparticles and platinum nanowires. Mikrochim Acta 2019; 186:598. [DOI: 10.1007/s00604-019-3703-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Accepted: 07/13/2019] [Indexed: 11/30/2022]
|
9
|
Affiliation(s)
- Khalil Khadim Hussain
- Department of Chemistry and Institute of BioPhysio Sensor Technology (IBST); Pusan National University; Busan 46241 S. Korea
| | - Jong-Min Moon
- Department of Chemistry and Institute of BioPhysio Sensor Technology (IBST); Pusan National University; Busan 46241 S. Korea
| | - Deog-Su Park
- Institute of BioPhysio Sensor Technology (IBST); Pusan National University; Busan 46241 S. Korea
| | - Yoon-Bo Shim
- Department of Chemistry and Institute of BioPhysio Sensor Technology (IBST); Pusan National University; Busan 46241 S. Korea
| |
Collapse
|
10
|
Justino CI, Duarte AC, Rocha-Santos TA. Critical overview on the application of sensors and biosensors for clinical analysis. Trends Analyt Chem 2016; 85:36-60. [PMID: 32287540 PMCID: PMC7112812 DOI: 10.1016/j.trac.2016.04.004] [Citation(s) in RCA: 66] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Sensors and biosensors have been increasingly used for clinical analysis due to their miniaturization and portability, allowing the construction of diagnostic devices for point-of-care testing. This paper presents an up-to-date overview and comparison of the analytical performance of sensors and biosensors recently used in clinical analysis. This includes cancer and cardiac biomarkers, hormones, biomolecules, neurotransmitters, bacteria, virus and cancer cells, along with related significant advances since 2011. Some methods of enhancing the analytical performance of sensors and biosensors through their figures of merit are also discussed.
Collapse
Affiliation(s)
- Celine I.L. Justino
- Department of Chemistry & CESAM, University of Aveiro, Campus de Santiago, 3810-193 Aveiro, Portugal
- ISEIT/Viseu, Instituto Piaget, Estrada do Alto do Gaio, Galifonge, 3515-776 Lordosa, Viseu, Portugal
| | - Armando C. Duarte
- Department of Chemistry & CESAM, University of Aveiro, Campus de Santiago, 3810-193 Aveiro, Portugal
| | - Teresa A.P. Rocha-Santos
- Department of Chemistry & CESAM, University of Aveiro, Campus de Santiago, 3810-193 Aveiro, Portugal
| |
Collapse
|
11
|
Kim DH, Cho IH, Park JN, Paek SH, Cho HM, Paek SH. Semi-continuous, real-time monitoring of protein biomarker using a recyclable surface plasmon resonance sensor. Biosens Bioelectron 2016; 88:232-239. [PMID: 27545847 DOI: 10.1016/j.bios.2016.08.035] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2016] [Revised: 08/04/2016] [Accepted: 08/12/2016] [Indexed: 11/16/2022]
Abstract
Although label-free immunosensors based on, for example, surface plasmon resonance (SPR) provide advantages of real-time monitoring of the analyte concentration, its application to routine clinical analysis in a semi-continuous manner is problematic because of the high cost of the sensor chip. The sensor chip is in most cases regenerated by employing an acidic pH. However, this causes gradual deterioration of the activity of the capture antibody immobilized on the sensor surface. To use sensor chips repeatedly, we investigated a novel surface modification method that enables regeneration of the sensor surface under mild conditions. We introduced a monoclonal antibody (anti-CBP Ab) that detects the conformational change in calcium binding protein (CBP) upon Ca2+ binding (>1mM). To construct a regenerable SPR-based immunosensor, anti-CBP Ab was first immobilized on the sensor surface, and CBP conjugated to the capture antibody (specific for creatine kinase-MB isoform (CK-MB); CBP-CAb) then bound in the presence of Ca2+. A serum sample was mixed with the detection antibody to CK-MB, which generated an SPR signal proportional to the analyte concentration. After each analysis, the sensor surface was regenerated using medium (pH 7) without Ca2+, and then adding fresh CBP-CAb in the presence of Ca2+ for the subsequent analysis. Analysis of multiple samples using the same sensor was reproducible at a rate >98.7%. The dose-response curve was linear for 1.75-500.75ng/mL CK-MB, with an acceptable coefficient of variation of <8.8%. The performance of the immunosensor showed a strong correlation with that of the Pathfast reference system (R2>96%), and exhibited analytical stability for 1 month. To our knowledge, this is the first report of a renewal of a sensor surface with fresh antibody after each analysis, providing high consistency in the assay during a long-term use (e.g., a month at least).
Collapse
Affiliation(s)
- Dong-Hyung Kim
- Department of Bio-Microsystem Technology, Korea University, 145 Anam-ro, Seongbuk-Gu, Seoul 02841, Republic of Korea
| | - Il-Hoon Cho
- Department of Biomedical Laboratory Science, College of Health Science, Eulji University, Seongnam 13135, Republic of Korea
| | - Ji-Na Park
- Department of Bio-Microsystem Technology, Korea University, 145 Anam-ro, Seongbuk-Gu, Seoul 02841, Republic of Korea
| | - Sung-Ho Paek
- Department of Bio-Microsystem Technology, Korea University, 145 Anam-ro, Seongbuk-Gu, Seoul 02841, Republic of Korea
| | - Hyun-Mo Cho
- Korea Research Institute of Standards and Science, P.O. Box 102, Yuseong, Taejon 34113, Republic of Korea
| | - Se-Hwan Paek
- Department of Bio-Microsystem Technology, Korea University, 145 Anam-ro, Seongbuk-Gu, Seoul 02841, Republic of Korea; Department of Biotechnology, Korea University, 2511 Sejong-ro, Sejong 30019, Republic of Korea.
| |
Collapse
|
12
|
Multiplexed electrochemical immunosensor for label-free detection of cardiac markers using a carbon nanofiber array chip. J Electroanal Chem (Lausanne) 2016. [DOI: 10.1016/j.jelechem.2016.04.034] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
13
|
Abnous K, Danesh NM, Sarreshtehdar Emrani A, Ramezani M, Taghdisi SM. A novel fluorescent aptasensor based on silica nanoparticles, PicoGreen and exonuclease III as a signal amplification method for ultrasensitive detection of myoglobin. Anal Chim Acta 2016; 917:71-8. [PMID: 27026602 DOI: 10.1016/j.aca.2016.02.036] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2016] [Revised: 02/22/2016] [Accepted: 02/27/2016] [Indexed: 10/22/2022]
Abstract
Measurement of myoglobin (Mb) in human blood serum is of great interest for quick diagnosis of acute myocardial infarction (AMI). In this study, a novel fluorescent aptasensor was designed for ultrasensitive and selective detection of Mb, based on target-induced high fluorescence intensity, complementary strand of aptamer (CS), PicoGreen (PG) dye, exonuclease III (Exo III) and silica nanoparticles coated with streptavidin (SNPs-Streptavidin). The developed aptasensor obtains characteristics of SNPs as enhancers of fluorescence intensity, Exo III as an enzyme which selectively digests the 3'-end of double-stranded DNA (dsDNA), PG as a fluorescent dye which could selectively bind to dsDNA and high selectivity and sensitivity of aptamer (Apt) toward its target. In the absence of Mb, no free CS remains in the environment of SNPs-Streptavidin, resulting in a weak fluorescence emission. In the present of Mb, dsDNA-modified SNPs-Streptavidin complex forms, leading to a very strong fluorescence emission. The developed fluorescent aptasensor exhibited high specificity toward Mb with a limit of detection (LOD) as low as 52 pM. In addition, the designed fluorescent aptasensor was efficiently used to detect Mb in human serum.
Collapse
Affiliation(s)
- Khalil Abnous
- Academic Center for Education, Culture and Research (ACECR)-Mashhad Branch, Mashhad, Iran; Pharmaceutical Research Center, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran.
| | - Noor Mohammad Danesh
- Nanotechnology Research Center, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran; Research Institute of Sciences and New Technology, Mashhad, Iran
| | | | - Mohammad Ramezani
- Nanotechnology Research Center, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Seyed Mohammad Taghdisi
- Targeted Drug Delivery Research Center, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran.
| |
Collapse
|
14
|
Taghdisi SM, Danesh NM, Ramezani M, Emrani AS, Abnous K. A novel electrochemical aptasensor based on Y-shape structure of dual-aptamer-complementary strand conjugate for ultrasensitive detection of myoglobin. Biosens Bioelectron 2016; 80:532-537. [PMID: 26894983 DOI: 10.1016/j.bios.2016.02.029] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2015] [Revised: 01/28/2016] [Accepted: 02/10/2016] [Indexed: 10/22/2022]
Abstract
Monitoring of myoglobin (Mb) in human blood serum is highly in demand for early diagnosis of acute myocardial infarction (AMI). Here, a novel electrochemical aptasensor was developed for ultrasensitive and selective detection of Mb, based on Y-shape structure of dual-aptamer (DApt)-complementary strand of aptamer (CS) conjugate, gold electrode and exonuclease I (Exo I). The designed aptasensor obtains features of gold, such as high electrochemical conductivity and large surface area, property of Y-shape structure of DApt-CS conjugate to function as a gate and obstacle for the access of redox probe to the surface of electrode, as well as high specificity and sensitivity of aptamer toward its target and Exo I as an enzyme which specifically degrades the 3'-end of single-stranded DNA (ssDNA). In the absence of Mb, the Y-shape structure remains intact. So, a weak electrochemical signal is observed. Upon addition of target, the DApt leave the CS and bind to Mb, leading to disassembly of Y-shape structure and following the addition of Exo I, a strong electrochemical signal could be recorded. The fabricated aptasensor showed high selectivity toward Mb with a limit of detection (LOD) as low as 27 pM. Besides, the developed aptasensor was effectively applied to detect Mb in human serum.
Collapse
Affiliation(s)
- Seyed Mohammad Taghdisi
- Targeted Drug Delivery Research Center, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Noor Mohammad Danesh
- Nanotechnology Research Center, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran; Research Institute of Sciences and New Technology, Mashhad, Iran
| | - Mohammad Ramezani
- Nanotechnology Research Center, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | | | - Khalil Abnous
- Pharmaceutical Research Center, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran.
| |
Collapse
|
15
|
Zhang B, Zhang Y, Liang W, Cui B, Li J, Yu X, Huang L. Nanogold-penetrated poly(amidoamine) dendrimer for enzyme-free electrochemical immunoassay of cardiac biomarker using cathodic stripping voltammetric method. Anal Chim Acta 2016; 904:51-7. [DOI: 10.1016/j.aca.2015.11.025] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2015] [Revised: 11/18/2015] [Accepted: 11/20/2015] [Indexed: 01/01/2023]
|
16
|
Abstract
The application of simple, cost-effective, rapid, and accurate diagnostic technologies for detection and identification of cardiac and cancer biomarkers has been a central point in the clinical area. Biosensors have been recognized as efficient alternatives for the diagnostics of various diseases due to their specificity and potential for application on real samples. The role of nanotechnology in the construction of immunological biosensors, that is, immunosensors, has contributed to the improvement of sensitivity, since they are based in the affinity between antibody and antigen. Other analytes than biomarkers such as hormones, pathogenic bacteria, and virus have also been detected by immunosensors for clinical point-of-care applications. In this chapter, we first introduced the various types of immunosensors and discussed their applications in clinical diagnostics over the recent 6 years, mainly as point-of-care technologies for the determination of cardiac and cancer biomarkers, hormones, pathogenic bacteria, and virus. The future perspectives of these devices in the field of clinical diagnostics are also evaluated.
Collapse
|
17
|
Shahabadi N, Maghsudi M, Shiri F. Application of a fluorescent biosensor based-on magneto-γ-Fe2O3-methyldopa nanoparticles for adsorption of human serum albumin. LUMINESCENCE 2015; 31:937-44. [DOI: 10.1002/bio.3053] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2015] [Revised: 09/19/2015] [Accepted: 09/23/2015] [Indexed: 12/12/2022]
Affiliation(s)
- Nahid Shahabadi
- Department of Inorganic Chemistry, Faculty of Chemistry; Razi University; Kermanshah Iran
- Medical Biology Research Center (MBRC); Kermanshah University of Medical Sciences; Kermanshah Iran
| | - Maryam Maghsudi
- Department of Inorganic Chemistry, Faculty of Chemistry; Razi University; Kermanshah Iran
| | - Farshad Shiri
- Department of Inorganic Chemistry, Faculty of Chemistry; Razi University; Kermanshah Iran
| |
Collapse
|
18
|
Moreira FTC, Sharma S, Dutra RAF, Noronha JPC, Cass AEG, Sales MGF. Detection of cardiac biomarker proteins using a disposable based on a molecularly imprinted polymer grafted onto graphite. Mikrochim Acta 2014. [DOI: 10.1007/s00604-014-1409-0] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|