1
|
Sadeghi MS, Sangrizeh FH, Jahani N, Abedin MS, Chaleshgari S, Ardakan AK, Baeelashaki R, Ranjbarpazuki G, Rahmanian P, Zandieh MA, Nabavi N, Aref AR, Salimimoghadam S, Rashidi M, Rezaee A, Hushmandi K. Graphene oxide nanoarchitectures in cancer therapy: Drug and gene delivery, phototherapy, immunotherapy, and vaccine development. ENVIRONMENTAL RESEARCH 2023; 237:117027. [PMID: 37659647 DOI: 10.1016/j.envres.2023.117027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Revised: 08/19/2023] [Accepted: 08/29/2023] [Indexed: 09/04/2023]
Abstract
The latest advancements in oncology involves the creation of multifunctional nanostructures. The integration of nanoparticles into the realm of cancer therapy has brought about a transformative shift, revolutionizing the approach to addressing existing challenges and limitations in tumor elimination. This is particularly crucial in combating the emergence of resistance, which has significantly undermined the effectiveness of treatments like chemotherapy and radiotherapy. GO stands as a carbon-derived nanoparticle that is increasingly finding utility across diverse domains, notably in the realm of biomedicine. The utilization of GO nanostructures holds promise in the arena of oncology, enabling precise transportation of drugs and genetic material to targeted sites. GO nanomaterials offer the opportunity to enhance the pharmacokinetic behavior and bioavailability of drugs, with documented instances of these nanocarriers elevating drug accumulation at the tumor location. The GO nanostructures encapsulate genes, shielding them from degradation and facilitating their uptake within cancer cells, thereby promoting efficient gene silencing. The capability of GO to facilitate phototherapy has led to notable advancements in reducing tumor progression. By PDT and PTT combination, GO nanomaterials hold the capacity to diminish tumorigenesis. GO nanomaterials have the potential to trigger both cellular and innate immunity, making them promising contenders for vaccine development. Additionally, types of GO nanoparticles that respond to specific stimuli have been applied in cancer eradication, as well as for the purpose of cancer detection and biomarker diagnosis. Endocytosis serves as the mechanism through which GO nanomaterials are internalized. Given these advantages, the utilization of GO nanomaterials for tumor elimination comes highly recommended.
Collapse
Affiliation(s)
- Mohammad Saleh Sadeghi
- Department of Pharmaceutics, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
| | | | - Negar Jahani
- Faculty of Veterinary Medicine, Islamic Azad University, Science and Research Branch, Tehran, Iran
| | - Mahdi Sadegh Abedin
- Student Research Committee, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Soheila Chaleshgari
- Department of Avian Diseases, Faculty of Veterinary Medicine, Chamran University, Ahvaz, Iran
| | - Alireza Khodaei Ardakan
- Faculty of Veterinary Medicine, Islamic Azad University, Science and Research Branch, Tehran, Iran
| | - Reza Baeelashaki
- Department of Food Hygiene and Quality Control, Division of Animal Feed Hygiene, Faculty of Veterinary Medicine, Islamic Azad University, Shabestar Branch, Shabestar, Iran
| | - Golnaz Ranjbarpazuki
- Student Research Committee, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Parham Rahmanian
- Faculty of Veterinary Medicine, Islamic Azad University, Science and Research Branch, Tehran, Iran
| | - Mohammad Arad Zandieh
- Department of Food Hygiene and Quality Control, Division of Epidemiology, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran
| | - Noushin Nabavi
- Department of Urologic Sciences, University of British Columbia, Vancouver, BC, V5Z 1M9, Canada
| | - Amir Reza Aref
- Department of Cancer Biology, Center for Cancer Systems Biology, Dana-Farber Cancer Institute, Department of Genetics, Harvard Medical School, Boston, MA, USA; Department of Translational Sciences, Xsphera Biosciences Inc. Boston, MA, USA
| | - Shokooh Salimimoghadam
- Department of Biochemistry and Molecular Biology, Faculty of Veterinary Medicine, Shahid Chamran University of Ahvaz, Ahvaz, Iran
| | - Mohsen Rashidi
- Department Pharmacology, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran; The Health of Plant and Livestock Products Research Center, Mazandaran University of Medical Sciences, Sari, Iran.
| | - Aryan Rezaee
- Student Research Committee, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.
| | - Kiavash Hushmandi
- Department of Food Hygiene and Quality Control, Division of Epidemiology, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran.
| |
Collapse
|
2
|
Li S, Zhang H, Zhu M, Kuang Z, Li X, Xu F, Miao S, Zhang Z, Lou X, Li H, Xia F. Electrochemical Biosensors for Whole Blood Analysis: Recent Progress, Challenges, and Future Perspectives. Chem Rev 2023. [PMID: 37262362 DOI: 10.1021/acs.chemrev.1c00759] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Whole blood, as one of the most significant biological fluids, provides critical information for health management and disease monitoring. Over the past 10 years, advances in nanotechnology, microfluidics, and biomarker research have spurred the development of powerful miniaturized diagnostic systems for whole blood testing toward the goal of disease monitoring and treatment. Among the techniques employed for whole-blood diagnostics, electrochemical biosensors, as known to be rapid, sensitive, capable of miniaturization, reagentless and washing free, become a class of emerging technology to achieve the target detection specifically and directly in complex media, e.g., whole blood or even in the living body. Here we are aiming to provide a comprehensive review to summarize advances over the past decade in the development of electrochemical sensors for whole blood analysis. Further, we address the remaining challenges and opportunities to integrate electrochemical sensing platforms.
Collapse
Affiliation(s)
- Shaoguang Li
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Hongyuan Zhang
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Man Zhu
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Zhujun Kuang
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Xun Li
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Fan Xu
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Siyuan Miao
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Zishuo Zhang
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Xiaoding Lou
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Hui Li
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Fan Xia
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| |
Collapse
|
3
|
Liu J, Kong T, Xiao Y, Bai L, Chen N, Tang H. Organic electrochemical transistor-based immuno-sensor using platinum loaded CeO2 nanosphere-carbon nanotube and zeolitic imidazolate framework-enzyme-metal polyphenol network. Biosens Bioelectron 2023; 230:115236. [PMID: 36989662 DOI: 10.1016/j.bios.2023.115236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 03/04/2023] [Accepted: 03/16/2023] [Indexed: 03/29/2023]
Abstract
This work demonstrates an organic electrochemical transistor (OECT) immuno-sensor with a detection limit down to fg mL-1. The OECT device transforms the antibody-antigen interaction signal by using the zeolitic imidazolate framework-enzyme-metal polyphenol network nanoprobe, which can produce electro-active substance (H2O2) through the enzyme-catalytic reaction. The produced H2O2 is subsequently electrochemically oxidized at the platinum loaded CeO2 nanosphere-carbon nanotube modified gate electrode, resulting in an amplified current response of the transistor device. This immuno-sensor realizes the selective determination of vascular endothelial growth factor 165 (VEGF165) down to the concentration of 13.6 fg mL-1. It also shows good applicable capacity for determining the VEGF165 that human brain microvascular endothelial cells and U251 human glioblastomas cells secreted in the cell culture medium. The ultrahigh sensitivity of the immuno-sensor is derived from excellent performances of the nanoprobe for enzyme loading and the OECT device for H2O2 detection. This work may provide a general way to fabricate the OECT immuno-sensing device with high performances.
Collapse
|
4
|
Mohammadpour-Haratbar A, Boraei SBA, Zare Y, Rhee KY, Park SJ. Graphene-Based Electrochemical Biosensors for Breast Cancer Detection. BIOSENSORS 2023; 13:bios13010080. [PMID: 36671915 PMCID: PMC9855997 DOI: 10.3390/bios13010080] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 12/21/2022] [Accepted: 12/28/2022] [Indexed: 06/04/2023]
Abstract
Breast cancer (BC) is the most common cancer in women, which is also the second most public cancer worldwide. When detected early, BC can be treated more easily and prevented from spreading beyond the breast. In recent years, various BC biosensor strategies have been studied, including optical, electrical, electrochemical, and mechanical biosensors. In particular, the high sensitivity and short detection time of electrochemical biosensors make them suitable for the recognition of BC biomarkers. Moreover, the sensitivity of the electrochemical biosensor can be increased by incorporating nanomaterials. In this respect, the outstanding mechanical and electrical performances of graphene have led to an increasingly intense study of graphene-based materials for BC electrochemical biosensors. Hence, the present review examines the latest advances in graphene-based electrochemical biosensors for BC biosensing. For each biosensor, the detection limit (LOD), linear range (LR), and diagnosis technique are analyzed. This is followed by a discussion of the prospects and current challenges, along with potential strategies for enhancing the performance of electrochemical biosensors.
Collapse
Affiliation(s)
- Ali Mohammadpour-Haratbar
- Biomaterials and Tissue Engineering Research Group, Department of Interdisciplinary Technologies, Breast Cancer Research Center, Motamed Cancer Institute, ACECR, Tehran 1715424313, Iran
| | - Seyyed Behnam Abdollahi Boraei
- Biomaterials and Tissue Engineering Research Group, Department of Interdisciplinary Technologies, Breast Cancer Research Center, Motamed Cancer Institute, ACECR, Tehran 1715424313, Iran
| | - Yasser Zare
- Biomaterials and Tissue Engineering Research Group, Department of Interdisciplinary Technologies, Breast Cancer Research Center, Motamed Cancer Institute, ACECR, Tehran 1715424313, Iran
| | - Kyong Yop Rhee
- Department of Mechanical Engineering (BK21 Four), College of Engineering, Kyung Hee University, Yongin 17104, Republic of Korea
| | - Soo-Jin Park
- Department of Chemistry, Inha University, Incheon 22212, Republic of Korea
| |
Collapse
|
5
|
Chinnadurai R. Advanced Technologies for Potency Assay Measurement. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2023; 1420:81-95. [PMID: 37258785 DOI: 10.1007/978-3-031-30040-0_6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Crucial for their application, cell products need to be well-characterized in the cell manufacturing facilities and conform to regulatory approval criteria before infusion into the patients. Mesenchymal Stromal Cells (MSCs) are the leading cell therapy candidate in clinical trials worldwide. Early phase clinical trials have demonstrated that MSCs display an excellent safety profile and are well tolerated. However, MSCs have also exhibited contradictory efficacy in later-phase clinical trials with reasons for this discrepancy including poorly understood mechanism of MSC therapeutic action. With likelihood that a number of attributes are involved in MSC derived clinical benefit, an assay that measures a single quality of may not adequately reflect potency, thus a combination of bioassays and analytical methods, collectively called "assay matrix" are favoured for defining the potency of MSC more adequately. This chapter highlights advanced technologies and targets that can achieve quantitative measurement for a range of MSC attributes, including immunological, genomic, secretome, phosphorylation, morphological, biomaterial, angiogenic and metabolic assays.
Collapse
Affiliation(s)
- Raghavan Chinnadurai
- Department of Biomedical Sciences, Mercer University School of Medicine, Savannah, GA, USA.
| |
Collapse
|
6
|
Detection and modulation of neurodegenerative processes using graphene-based nanomaterials: Nanoarchitectonics and applications. Adv Colloid Interface Sci 2023; 311:102824. [PMID: 36549182 DOI: 10.1016/j.cis.2022.102824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 12/02/2022] [Accepted: 12/08/2022] [Indexed: 12/14/2022]
Abstract
Neurodegenerative disorders (NDDs) are caused by progressive loss of functional neurons following the aggregation and fibrillation of proteins in the central nervous system. The incidence rate continues to rise alarmingly worldwide, particularly in aged population, and the success of treatment remains limited to symptomatic relief. Graphene nanomaterials (GNs) have attracted immense interest on the account of their unique physicochemical and optoelectronic properties. The research over the past two decades has recognized their ability to interact with aggregation-prone neuronal proteins, regulate autophagy and modulate the electrophysiology of neuronal cells. Graphene can prevent the formation of higher order protein aggregates and facilitate the clearance of such deposits. In this review, after highlighting the role of protein fibrillation in neurodegeneration, we have discussed how GN-protein interactions can be exploited for preventing neurodegeneration. A comprehensive understanding of such interactions would contribute to the exploration of novel modalities for controlling neurodegenerative processes.
Collapse
|
7
|
Current Update on Biomarkers for Detection of Cancer: Comprehensive Analysis. Vaccines (Basel) 2022; 10:vaccines10122138. [PMID: 36560548 PMCID: PMC9787556 DOI: 10.3390/vaccines10122138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 10/27/2022] [Accepted: 11/23/2022] [Indexed: 12/15/2022] Open
Abstract
Early and effective diagnosis of cancer is decisive for its proper management. In this context biomarker-based cancer diagnosis is budding as one of the promising ways for early detection, disease progression monitoring, and effective cancer therapy. Integration of Biosensing devices with different metallic/nonmetallic nanoparticles offers amplification and multiplexing capabilities for simultaneous detection of cancer biomarkers (CB's). This study provides a comprehensive analysis of the most recent designs and fabrication methodologies designed for developing electrochemical biosensors (EB) for early detection of cancers. The role of biomarkers in cancer therapeutics is also discussed.
Collapse
|
8
|
Kanjwal MA, Ghaferi AA. Advanced Waveguide Based LOC Biosensors: A Minireview. SENSORS (BASEL, SWITZERLAND) 2022; 22:5443. [PMID: 35891123 PMCID: PMC9323137 DOI: 10.3390/s22145443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 06/28/2022] [Accepted: 07/13/2022] [Indexed: 06/15/2023]
Abstract
This mini review features contemporary advances in mid-infrared (MIR) thin-film waveguide technology and on-chip photonics, promoting high-performance biosensing platforms. Supported by recent developments in MIR thin-film waveguides, it is expected that label-free assimilated MIR sensing platforms will soon supplement the current sensing technologies for biomedical diagnostics. The state-of-the-art shows that various types of waveguide material can be utilized for waveguide spectroscopic measurements in MIR. However, there are challenges to integrating these waveguide platforms with microfluidic/Lab-on-a-Chip (LOC) devices, due to poor light-material interactions. Graphene and its analogs have found many applications in microfluidic-based LOC devices, to address to this issue. Graphene-based materials possess a high conductivity, a large surface-to-volume ratio, a smaller and tunable bandgap, and allow easier sample loading; which is essential for acquiring precise electrochemical information. This work discusses advanced waveguide materials, their advantages, and disease diagnostics with MIR thin-film based waveguides. The incorporation of graphene into waveguides improves the light-graphene interaction, and photonic devices greatly benefit from graphene's strong field-controlled optical response.
Collapse
|
9
|
Arshad F, Nabi F, Iqbal S, Khan RH. Applications of graphene-based electrochemical and optical biosensors in early detection of cancer biomarkers. Colloids Surf B Biointerfaces 2022; 212:112356. [PMID: 35123193 DOI: 10.1016/j.colsurfb.2022.112356] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 01/04/2022] [Accepted: 01/19/2022] [Indexed: 12/26/2022]
Abstract
Graphene is a one-atom-thick carbon compound, which holds promises for detecting cancer biomarkers along with its derivatives. The atom-wide graphene layer is ideal for cancer biomarker detection due to its unique physicochemical properties like increased electrical and thermal conductivity, optical transparency, and enhanced chemical and mechanical strength. The scientific aim of any biosensor is to create a smaller and portable point of care device for easy and early cancer detection; graphene is able to live up to that. Apart from tumour detection, graphene-based biosensors can diagnose many diseases, their biomarkers, and pathogens. Many existing remarkable pieces of research have proven the candidacy of nanoparticles in most cancer biomarkers detection. This article discusses the effectiveness of graphene-based biosensors in different cancer biomarker detection. This article provides a detailed review of graphene and its derivatives that can be used to detect cancer biomarkers with high specificity, sensitivity, and selectivity. We have highlighted the synthesis procedures of graphene and its products and also discussed their significant properties. Furthermore, we provided a detailed overview of the recent studies on cancer biomarker detection using graphene-based biosensors. The different paths to create and modify graphene surfaces for sensory applications have also been highlighted in each section. Finally, we concluded the review by discussing the existing challenges of these biosensors and also highlighted the steps that can be taken to overcome them.
Collapse
Affiliation(s)
- Fareeha Arshad
- Department of Biochemistry, Aligarh Muslim University, Aligarh 202001, India
| | - Faisal Nabi
- Interdisciplinary Biotechnology Unit, Aligarh Muslim University, Aligarh 202001, India
| | - Sana Iqbal
- Department of Electrical Engineering, Aligarh Muslim University, Aligarh 202001, India
| | - Rizwan Hasan Khan
- Interdisciplinary Biotechnology Unit, Aligarh Muslim University, Aligarh 202001, India.
| |
Collapse
|
10
|
Tiwari A, Chaskar J, Ali A, Arivarasan VK, Chaskar AC. Role of Sensor Technology in Detection of the Breast Cancer. BIONANOSCIENCE 2022. [DOI: 10.1007/s12668-021-00921-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
11
|
Brooks AK, Chakravarty S, Yadavalli VK. Flexible Sensing Systems for Cancer Diagnostics. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1379:275-306. [DOI: 10.1007/978-3-031-04039-9_11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
12
|
Baghbaderani SS, Mokarian P, Moazzam P. A Review on Electrochemical Sensing of Cancer Biomarkers Based on
Nanomaterial - Modified Systems. CURR ANAL CHEM 2022. [DOI: 10.2174/1573411016999200917161657] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Diagnosis of cancer in the early stages can help treat efficiently and reduce cancerrelated
death. Cancer biomarkers can respond to the presence of cancer in body fluids before the
appearance of any other symptoms of cancer. The integration of nanomaterials into biosensors as
electrochemical platforms offer rapid, sensitive detection for cancer biomarkers. The use of surface-
modified electrodes by carbon nanomaterials and metal nanoparticles enhances the performance
of electrochemical analysis in biosensing systems through the increase of bioreceptors loading
capacity on the surface. In this review, novel approaches based on nanomaterial-modified systems
in the point of care diagnostics are highlighted.
Collapse
Affiliation(s)
- Sorour Salehi Baghbaderani
- Department of Nanotechnology Engineering, Faculty of Advanced Sciences and Technologies, University of Isfahan, Isfahan 81746-73441,Iran
| | - Parastou Mokarian
- Department of Biology, Faculty of Sciences, Central Tehran Branch, Islamic Azad University, Tehran 14676-86831,Iran
| | - Parisa Moazzam
- School of Chemistry, University of New South Wales, Sydney, 2052,Australia
| |
Collapse
|
13
|
Sharifianjazi F, Jafari Rad A, Bakhtiari A, Niazvand F, Esmaeilkhanian A, Bazli L, Abniki M, Irani M, Moghanian A. Biosensors and nanotechnology for cancer diagnosis (lung and bronchus, breast, prostate, and colon): a systematic review. Biomed Mater 2021; 17. [PMID: 34891145 DOI: 10.1088/1748-605x/ac41fd] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Accepted: 12/10/2021] [Indexed: 12/22/2022]
Abstract
The second cause of death in the world has been reported to be cancer, and it has been on the rise in recent years. As a result of the difficulties of cancer detection and its treatment, the survival rate of patients is unclear. The early detection of cancer is an important issue for its therapy. Cancer detection based on biomarkers may effectively enhance the early detection and subsequent treatment. Nanomaterial-based nanobiosensors for cancer biomarkers are excellent tools for the molecular detection and diagnosis of disease. This review reports the latest advancement and attainment in applying nanoparticles to the detection of cancer biomarkers. In this paper, the recent advances in the application of common nanomaterials like graphene, carbon nanotubes, Au, Ag, Pt, and Fe3O4together with newly emerged nanoparticles such as quantum dots, upconversion nanoparticles, inorganics (ZnO, MoS2), and metal-organic frameworks for the diagnosis of biomarkers related to lung, prostate, breast, and colon cancer are highlighted. Finally, the challenges, outlook, and closing remarks are given.
Collapse
Affiliation(s)
| | - Azadeh Jafari Rad
- Department of Chemistry, Islamic Azad University, Omidiyeh Branch, Omidiyeh, Iran
| | | | - Firoozeh Niazvand
- School of Medicine, Abadan University of Medical Sciences, Abadan, Iran
| | | | - Leila Bazli
- School of Metallurgy and Materials Engineering, Iran University of Science and Technology (IUST), Narmak, Tehran, Iran
| | - Milad Abniki
- Department of Resin and Additives, Institute for Color Science and Technology, Tehran, Iran
| | - Mohammad Irani
- Dentistry Clinical Research Development Unit, Alborz University of Medical Sciences, Karaj, Iran
| | - Amirhossein Moghanian
- Department of Materials Engineering, Imam Khomeini International University, Qazvin 34149-16818, Iran
| |
Collapse
|
14
|
Yildiz G, Bolton-Warberg M, Awaja F. Graphene and graphene oxide for bio-sensing: General properties and the effects of graphene ripples. Acta Biomater 2021; 131:62-79. [PMID: 34237423 DOI: 10.1016/j.actbio.2021.06.047] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 05/21/2021] [Accepted: 06/29/2021] [Indexed: 02/08/2023]
Abstract
The use of Graphene based materials, such as graphene oxide (GO), in biosensing applications is gaining significant interest, due to high signal output, with strong potential for high industrial growth rate. Graphene's excellent conduction and mechanical properties (such as toughness and elasticity) coupled with high reactivity to chemical molecules are some of its appealing properties. The presence of ripples on the surface (whether indigenous or induced) represents another property/variable that provide enormous potential if harnessed properly. In this article, we review the current knowledge regarding the use of graphene for biosensing. We discuss briefly the general topic of using graphene for biosensing applications with special emphasis on wearable graphene-based biosensors. The intrinsic ripples of graphene and their effect on graphene biosensing capabilities are thoroughly discussed. We dedicate a section also for the manipulation of intrinsic ripples. Then we review the use of Graphene oxide (GO) in biosensing and discuss the effect of ripples on its properties. We present a review of the current biosensor devices made out of GO for detection of different molecular targets. Finally, we present some thoughts for future perspectives and opportunities of this field. STATEMENT OF SIGNIFICANCE: Biosensors are tools that detect the presence and amount of a chemical substance, such as pregnancy tests and glucose monitoring devices. They are general portable, have short response times and are sensitive, making them highly effective. Gold and silver are used in biosensors and more recently, graphene. Graphene is sheets of carbon atoms and is the only two-dimensional crystal in nature. It has unique features allowing its effective use in biosensing applications, including the presence of ripples (non-flat areas that give it its electronic properties). The last comprehensive review of this topic was published in 2016. This paper reviews the current knowledge of graphene based biosensors, with a focus on ripples and their effect on graphene biosensing capabilities.
Collapse
|
15
|
Sattari S, Adeli M, Beyranvand S, Nemati M. Functionalized Graphene Platforms for Anticancer Drug Delivery. Int J Nanomedicine 2021; 16:5955-5980. [PMID: 34511900 PMCID: PMC8416335 DOI: 10.2147/ijn.s249712] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Accepted: 06/17/2021] [Indexed: 12/24/2022] Open
Abstract
Two-dimensional nanomaterials are emerging as promising candidates for a wide range of biomedical applications including tissue engineering, biosensing, pathogen incapacitation, wound healing, and gene and drug delivery. Graphene, due to its high surface area, photothermal property, high loading capacity, and efficient cellular uptake, is at the forefront of these materials and plays a key role in this multidisciplinary research field. Poor water dispersibility and low functionality of graphene, however, hamper its hybridization into new nanostructures for future nanomedicine. Functionalization of graphene, either by covalent or non-covalent methods, is the most useful strategy to improve its dispersion in water and functionality as well as processability into new materials and devices. In this review, recent advances in functionalization of graphene derivatives by different (macro)molecules for future biomedical applications are reported and explained. In particular, hydrophilic functionalization of graphene and graphene oxide (GO) to improve their water dispersibility and physicochemical properties is discussed. We have focused on the anticancer drug delivery of polyfunctional graphene sheets.
Collapse
Affiliation(s)
- Shabnam Sattari
- Department of Chemistry, Faculty of Science, Lorestan University, Khorramabad, Iran
| | - Mohsen Adeli
- Department of Chemistry, Faculty of Science, Lorestan University, Khorramabad, Iran
| | - Siamak Beyranvand
- Department of Chemistry, Faculty of Science, Lorestan University, Khorramabad, Iran
| | - Mohammad Nemati
- Department of Chemistry, Faculty of Science, Lorestan University, Khorramabad, Iran
| |
Collapse
|
16
|
Novel Prostate Cancer Biomarkers: Aetiology, Clinical Performance and Sensing Applications. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9080205] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The review initially provides a short introduction to prostate cancer (PCa) incidence, mortality, and diagnostics. Next, the need for novel biomarkers for PCa diagnostics is briefly discussed. The core of the review provides details about PCa aetiology, alternative biomarkers available for PCa diagnostics besides prostate specific antigen and their biosensing. In particular, low molecular mass biomolecules (ions and metabolites) and high molecular mass biomolecules (proteins, RNA, DNA, glycoproteins, enzymes) are discussed, along with clinical performance parameters.
Collapse
|
17
|
He Y, Yi C, Zhang X, Zhao W, Yu D. Magnetic graphene oxide: Synthesis approaches, physicochemical characteristics, and biomedical applications. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116191] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
18
|
Disha, Kumari P, Nayak MK, Kumar P. An electrochemical biosensing platform for progesterone hormone detection using magnetic graphene oxide. J Mater Chem B 2021; 9:5264-5271. [PMID: 34151922 DOI: 10.1039/d1tb00380a] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
In recent times, graphene and its derivatives have turned out to be emerging nanomaterials as transducers to promote electron transport in the field of biosensing using electrochemical techniques. In electrochemical biosensing strategies, key factors such as signal amplification, stability, and sensitivity are necessary for attaining improved sensor performance. In the present work, we synthesized magnetic nanocomposites of graphene oxide and employed them as an electrode material for the loading of bio receptors. The increased surface area with high electric conductance enhanced the sensor's response. The immobilization of progesterone (PGN) antibodies on the modified electrode-sensing surface led to a hindered electron transport that decreased the current response. The developed electrochemical immunosensor assembled successfully in a stepwise process using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) studies along with the electrochemical impedance spectroscopy (EIS) analysis. The current response decreased linearly with the increased progesterone (PGN) concentration range of 0.01 pM-1000 nM with excellent detection limits of 0.15 pM (DPV) and 0.17 pM (CV) under optimal experimental conditions. The label-free electrochemical immunosensor has shown a promising platform for rapid and direct analysis of PGN due to its high sensitivity, selectivity, stability, and repeatability in water samples.
Collapse
Affiliation(s)
- Disha
- CSIR-Central Scientific Instrument Organisation (CSIR-CSIO), Chandigarh 160030, India. and Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Poonam Kumari
- CSIR-Central Scientific Instrument Organisation (CSIR-CSIO), Chandigarh 160030, India. and Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Manoj K Nayak
- CSIR-Central Scientific Instrument Organisation (CSIR-CSIO), Chandigarh 160030, India. and Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Parveen Kumar
- CSIR-Central Scientific Instrument Organisation (CSIR-CSIO), Chandigarh 160030, India.
| |
Collapse
|
19
|
Yáñez-Sedeño P, González-Cortés A, Campuzano S, Pingarrón JM. Multimodal/Multifunctional Nanomaterials in (Bio)electrochemistry: Now and in the Coming Decade. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E2556. [PMID: 33352731 PMCID: PMC7766190 DOI: 10.3390/nano10122556] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Revised: 12/13/2020] [Accepted: 12/16/2020] [Indexed: 01/15/2023]
Abstract
Multifunctional nanomaterials, defined as those able to achieve a combined effect or more than one function through their multiple functionalization or combination with other materials, are gaining increasing attention in the last years in many relevant fields, including cargo targeted delivery, tissue engineering, in vitro and/or in vivo diseases imaging and therapy, as well as in the development of electrochemical (bio)sensors and (bio)sensing strategies with improved performance. This review article aims to provide an updated overview of the important advances and future opportunities exhibited by electrochemical biosensing in connection to multifunctional nanomaterials. Accordingly, representative aspects of recent approaches involving metal, carbon, and silica-based multifunctional nanomaterials are selected and critically discussed, as they are the most widely used multifunctional nanomaterials imparting unique capabilities in (bio)electroanalysis. A brief overview of the main remaining challenges and future perspectives in the field is also provided.
Collapse
Affiliation(s)
- Paloma Yáñez-Sedeño
- Departamento de Química Analítica, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain; (A.G.-C.); (J.M.P.)
| | | | - Susana Campuzano
- Departamento de Química Analítica, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain; (A.G.-C.); (J.M.P.)
| | | |
Collapse
|
20
|
Li Z, Liu Y, Chen X, Cao H, Shen H, Mou L, Deng X, Jiang X, Cong Y. Surface-modified mesoporous nanofibers for microfluidic immunosensor with an ultra-sensitivity and high signal-to-noise ratio. Biosens Bioelectron 2020; 166:112444. [PMID: 32758910 DOI: 10.1016/j.bios.2020.112444] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 06/17/2020] [Accepted: 07/09/2020] [Indexed: 12/31/2022]
Abstract
How to balance the sensitivity and signal-to-noise ratio of immunosensor remains many challenges during various diseases diagnosis. Here we develop a new microfluidic immunosensor based on surface-modified mesoporous nanofibers, and simultaneously realize an ultra-sensitivity and high signal-to-noise ratio for the detection of multiple biomarkers. In the current study, we fabricated titanium dioxide (TiO2)-based mesoporous electrospinning nanofibers, and modified nanofiber surface with both octadecylphosphonic acid (OPA) and poly(ethylene oxide)-poly(propylene oxide) triblock copolymer (PEO-PPO-PEO). Such nanofibers as solid substrate are covered on microfluidic channels. The porosity of our nanofibers dramatically increased the adsorption capability of antibodies, realizing an ultra sensitivity of biomarker detection. PEO-PPO-PEO modification can significantly block non-specific absorptions, obtaining a satisfied signal-to-noise ratio. For the detection of HIV p24 and interleukin 5 (IL-5), our immunosensor increased 6.41 and 6.93 fold in sensitivity and improved 504.66% and 512.80% in signal-to-noise ratio, in compared with gold standard immunoassay (ELISA) used in the clinic. Our immunosensor also broaden the linear range for the detection of HIV p24 (0.86-800 pg/ml) and IL-5 (0.70-800 pg/ml), in compared with ELISA which is 5.54-500 pg/ml for HIV p24 and 4.84-500 pg/ml for IL-5. Our work provided a guideline for the construction of advanced point-of-care immunosensor with an ultra-sensitivity and high signal-to-noise ratio for disease diagnosis.
Collapse
Affiliation(s)
- Zulan Li
- PLA Medical College and Clinical Laboratory of Second Medical Center of PLA General Hospital, No. 28 Fuxing Road, Beijing, 100853, China
| | - Ye Liu
- Institute of Medical Biology, Chinese Academy of Medical Sciences and Peking Union Medical College, Kunming, Yunnan, 650000, China.
| | - Xingming Chen
- Laboratory Department of PLA Strategic Support Force Characteristic Medical Center, Beijing, 100101, China
| | - Hongyan Cao
- PLA Medical College and Clinical Laboratory of Second Medical Center of PLA General Hospital, No. 28 Fuxing Road, Beijing, 100853, China
| | - Haiying Shen
- Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong, 518055, China
| | - Lei Mou
- Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong, 518055, China
| | - Xinli Deng
- PLA Medical College and Clinical Laboratory of Second Medical Center of PLA General Hospital, No. 28 Fuxing Road, Beijing, 100853, China
| | - Xingyu Jiang
- Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong, 518055, China
| | - Yulong Cong
- PLA Medical College and Clinical Laboratory of Second Medical Center of PLA General Hospital, No. 28 Fuxing Road, Beijing, 100853, China
| |
Collapse
|
21
|
Cao H, Liu Y, Sun H, Li Z, Gao Y, Deng X, Shao Y, Cong Y, Jiang X. Increasing the Assembly Efficacy of Peptidic β-Sheets for a Highly-Sensitive HIV Detection. Anal Chem 2020; 92:11089-11094. [PMID: 32602727 DOI: 10.1021/acs.analchem.0c00951] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Our recent publication illustrates the critical role of phenylalanine-mediated aromatic-aromatic interactions in determining the assembly of peptidic β-sheets. However, the effect of phenylalanine number on regulating the assembly efficacy of peptidic β-sheets remains poorly understood. We herein evaluate the assembly efficacy of β-sheets of a series of oligopeptides which contain 0, 1, 2, or 3 phenylalanine in their molecular backbones. In our assembly system, two phenylalanine (2F) is the minimum number for driving the assembly of β-sheets of oligopeptides. Oligopeptides with three phenylalanine (3F) show significantly increased assembly efficacy of β-sheets compared to that with 2F. These results suggest a positive correlation between the phenylalanine number and assembly efficacy of β-sheets. By improving the assembly efficacy of β-sheets, we further develop a highly sensitive HIV analytical system in which the specific binding of β-sheets with Congo Red induces enhanced fluorescence. For HIV p24 detection, the 3F-based analytical system (0.61 pg/mL) shows a significantly lower limit of detection (LOD) than the 2F-based analytical system (2.44 pg/mL), both of which are more sensitive than commercial ELISA (5 pg/mL) used in the clinic. This work not only illustrates the effect of phenylalanine number on regulating the assembly efficacy of β-sheets but also provides a guideline for the construction of a highly sensitive analytical system of disease diagnosis.
Collapse
Affiliation(s)
- Hongyan Cao
- PLA Medical College and Clinical Laboratory of Second Medical Center of PLA General Hospital, No. 28 Fuxing Road, Beijing 100853, China
| | - Ye Liu
- Institute of Medical Biology, Chinese Academy of Medical Sciences and Peking Union Medical College, Kunming, Yunnan 65000, P. R. China
| | - Hongyan Sun
- Beijing Engineering Research Center for Bionanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, P. R. China
| | - Zulan Li
- PLA Medical College and Clinical Laboratory of Second Medical Center of PLA General Hospital, No. 28 Fuxing Road, Beijing 100853, China.,Beijing Engineering Research Center for Bionanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, P. R. China
| | - Yuan Gao
- Beijing Engineering Research Center for Bionanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, P. R. China
| | - Xinli Deng
- PLA Medical College and Clinical Laboratory of Second Medical Center of PLA General Hospital, No. 28 Fuxing Road, Beijing 100853, China
| | - Yiming Shao
- State Key Laboratory of Infectious Disease Prevention and Control, National Center for AIDS/STD Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 100190, China
| | - Yulong Cong
- PLA Medical College and Clinical Laboratory of Second Medical Center of PLA General Hospital, No. 28 Fuxing Road, Beijing 100853, China
| | - Xingyu Jiang
- Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Road, Nanshan District, Shenzhen, Guangdong 518055, P. R. China.,University of Chinese Academy of Sciences, 19 A Yuquan Road, Shijingshan District, Beijing 100049, P. R. China.,Beijing Engineering Research Center for Bionanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, P. R. China
| |
Collapse
|
22
|
Zida SI, Yang CC, Khung YL, Lin YD. Fabrication and Characterization of an Aptamer-Based N-type Silicon Nanowire FET Biosensor for VEGF Detection. J Med Biol Eng 2020. [DOI: 10.1007/s40846-020-00552-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
23
|
Jarczewska M, Malinowska E. The application of antibody-aptamer hybrid biosensors in clinical diagnostics and environmental analysis. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:3183-3199. [PMID: 32930180 DOI: 10.1039/d0ay00678e] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The growing number of various diseases and the increase of environmental contamination are the causes for the development of novel methods for their detection. The possibility of the application of affinity-based biosensors for such purposes seems particularly promising as they provide high selectivity and low detection limits. Recently, the usage of hybrid antibody-aptamer sandwich constructs was shown to be more advantageous in terms of working parameters in comparison to aptamer-based and immune-based biosensors. This review is focused on the usage of hybrid antibody-aptamer receptor layers for the determination of clinically and environmentally important target molecules. In this work, antibodies and aptamer molecules are characterized and the methods of their immobilization as well as analytical signal generation are shown. This is followed by the critical presentation of examples of hybrid sandwich biosensors that have been elaborated in the past 12 years.
Collapse
Affiliation(s)
- Marta Jarczewska
- The Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Noakowskiego 3, Warsaw, 00-664, Poland.
| | - Elżbieta Malinowska
- The Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Noakowskiego 3, Warsaw, 00-664, Poland.
- Centre for Advanced Materials and Technologies CEZAMAT, Poleczki 19, 02-822 Warsaw, Poland
| |
Collapse
|
24
|
Ghavamipour F, Rahmani H, Shanehsaz M, Khajeh K, Mirshahi M, Sajedi RH. Enhanced sensitivity of VEGF detection using catalase-mediated chemiluminescence immunoassay based on CdTe QD/H 2O 2 system. J Nanobiotechnology 2020; 18:93. [PMID: 32552818 PMCID: PMC7302009 DOI: 10.1186/s12951-020-00648-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 06/11/2020] [Indexed: 02/06/2023] Open
Abstract
Background Since vascular endothelial growth factor (VEGF) is a significant regulator of cancer angiogenesis, it is essential to develop a technology for its sensitive detection. Herein, we sensitized a chemiluminescence (CL) immunoassay through the combination of H2O2-sensitive TGA-CdTe quantum dot (QD) as signal transduction, dextran as a cross-linker to prepare enzyme-labeled antigen and the ultrahigh bioactivity of catalase (CAT) as reporter enzyme. Results Under the optimized experimental conditions, the chemiluminescence enzyme-linked immunosorbent assay (CL-ELISA) method can detect VEGF in the excellent linear range of 2–35,000 pg mL−1, with a detection limit (S/N = 3) of 0.5 pg mL−1 which was approximately ten times lower than the commercial colorimetric immunoassay. This proposed method has been successfully applied to the clinical determination of VEGF in the human serum samples, and the results illustrated an excellent correlation with the conventional ELISA method (R2 = 0.997). The suitable recovery rate of the method in the serum ranged from 97 to 107%, with a relative standard deviation of 1.2% to 13.4%. Conclusions The novel immunoassay proposes a highly sensitive, specific, and stable method for very low levels detection of VEGF that can be used in the primary diagnosis of tumors. With the well-designed sensing platform, this approach has a broad potential to be applied for quantitative analysis of numerous disease-related protein biomarkers for which antibodies are available.![]()
Collapse
Affiliation(s)
- Fahimeh Ghavamipour
- Department of Biochemistry, Faculty of Biological Sciences, Tarbiat Modares University, Tehran, 14115-154, Iran
| | - Hossein Rahmani
- Department of Biochemistry, Faculty of Biological Sciences, Tarbiat Modares University, Tehran, 14115-154, Iran
| | - Maryam Shanehsaz
- Analytical Chemistry Research Laboratory, Mobin Shimi Azma Company, Tehran, Iran
| | - Khosro Khajeh
- Department of Biochemistry, Faculty of Biological Sciences, Tarbiat Modares University, Tehran, 14115-154, Iran
| | - Manouchehr Mirshahi
- Department of Biochemistry, Faculty of Biological Sciences, Tarbiat Modares University, Tehran, 14115-154, Iran
| | - Reza H Sajedi
- Department of Biochemistry, Faculty of Biological Sciences, Tarbiat Modares University, Tehran, 14115-154, Iran.
| |
Collapse
|
25
|
Cui L, Liang J, Liu H, Zhang K, Li J. Nanomaterials for Angiogenesis in Skin Tissue Engineering. TISSUE ENGINEERING PART B-REVIEWS 2020; 26:203-216. [PMID: 31964266 DOI: 10.1089/ten.teb.2019.0337] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Damage to skin tissue, which causes the disorder of the patient's body homeostasis, threatens the patient's life and increases the personal and social treatment burden. Angiogenesis, a key step in the wound healing process, provides sufficient oxygen and nutrients to the wound area. However, traditional clinical interventions are not enough to stabilize the formation of the vascular system to support wound healing. Due to the unique properties and multiple functions of nanomaterials, it has made a major breakthrough in the application of medicine. Nanomaterials provide a more effective treatment to hasten the angiogenesis and wound healing, by stimulating fundamental factors in the vascular regeneration phase. In the present review article, the basic stages and molecular mechanisms of angiogenesis are analyzed, and the types, applications, and prospects of nanomaterials used in angiogenesis are detailed. Impact statement Wound healing (especially chronic wounds) is currently a clinically important issue. The long-term nonhealing of chronic wounds often plagues patients, medical systems, and causes huge losses to the social economy. There is currently no effective method of treating chronic wounds in the clinic. Angiogenesis is an important step in wound healing. Nanomaterials had properties that are not found in conventional materials, and they have been extensively studied in angiogenesis. This review article provides readers with the molecular mechanisms of angiogenesis and the types and applications of angiogenic nanomaterials, hoping to bring inspiration to overcome chronic wounds.
Collapse
Affiliation(s)
- Longlong Cui
- School of Life Science, Zhengzhou University, Zhengzhou, China
| | - Jiaheng Liang
- School of Life Science, Zhengzhou University, Zhengzhou, China
| | - Han Liu
- School of Life Science, Zhengzhou University, Zhengzhou, China
| | - Kun Zhang
- School of Life Science, Zhengzhou University, Zhengzhou, China
| | - Jingan Li
- Henan Key Laboratory of Advanced Magnesium Alloy, Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), School of Material Science and Engineering, Zhengzhou University, Zhengzhou, China
| |
Collapse
|
26
|
Dong J, He L, Wang Y, Yu F, Yu S, Liu L, Wang J, Tian Y, Qu L, Han R, Wang Z, Wu Y. A highly sensitive colorimetric aptasensor for the detection of the vascular endothelial growth factor in human serum. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2020; 226:117622. [PMID: 31606672 DOI: 10.1016/j.saa.2019.117622] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 07/23/2019] [Accepted: 10/06/2019] [Indexed: 06/10/2023]
Abstract
Early detection of cancer is of great significance for disease prevention and diagnosis. However, the levels of most cancer markers are quite low in the early stages of disease, so it is urgent to develop a highly sensitive detection method. In this study, a label-free and highly sensitive colorimetric strategy was developed for the detection of the vascular endothelial growth factor165 (VEGF165) in human serum. First, a convenient biosensor was constructed by immobilizing VEGF165 on a microplate, where aptamers bound with VEGF165 to form a complex. Then, streptavidin labeled-horseradish peroxidase (HRP-SA) combined with the complex via the interaction between streptavidin and biotin, thus catalyzing the 3,3',5,5'-tetramethylbenzidine (TMB) and H2O2 system to produce colored products. In the presence of target, immobilized VEGF165 and target competitively bound with the aptamers, resulting in a reduction of the colorimetric signal. Moreover, the optical density (OD) signal decreased with the increase of target concentration. The strategy showed a broad linear range (0.1-100 ng/mL) and a rather low detection limit of 10 pg/mL with good precision and selectivity. Further, the proposed method was successfully applied in detecting VEGF165 in human serum. The detection results of serum samples showed that the proposed assay had a high correlation with CLEIA kits (r = 0.971, P = 0.001). It has potential for application in clinical research and diagnosis.
Collapse
Affiliation(s)
- Jiajia Dong
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China; College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou, 450001, China
| | - Leiliang He
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Yilin Wang
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Fei Yu
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Songcheng Yu
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Lie Liu
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Jia Wang
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Yongmei Tian
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Lingbo Qu
- College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou, 450001, China
| | - Runping Han
- College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou, 450001, China
| | - Ziling Wang
- Henan Provincial Chest Hospital, Zhengzhou, 450001, China.
| | - Yongjun Wu
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China; The Key Laboratory of Nanomedicine and Health Inspection of Zhengzhou, Zhengzhou, 450001, China.
| |
Collapse
|
27
|
Pham XH, Hahm E, Kim HM, Son BS, Jo A, An J, Tran Thi TA, Nguyen DQ, Jun BH. Silica-Coated Magnetic Iron Oxide Nanoparticles Grafted onto Graphene Oxide for Protein Isolation. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E117. [PMID: 31936217 PMCID: PMC7022723 DOI: 10.3390/nano10010117] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Revised: 01/04/2020] [Accepted: 01/06/2020] [Indexed: 12/12/2022]
Abstract
In this study, silica-coated magnetic iron oxide nanoparticles (MNPs@SiO2) were covalently conjugated onto graphene oxide (GO/MNP@SiO2) for protein isolation. First, MNPs were precisely coated with a silica layer on the surface by using the reverse microemulsion method, followed by incubation with 3-glycidyloxypropyltrimethoxysilane (GPTS) to produce the GPTS-functionalized MNPs@SiO2 (GPTS-coated MNPs@SiO2) that display epoxy groups on the surface. The silica shell on the MNPs was optimized at 300 µL of Igepal®CO-520, 5 mg of MNP, 100 µL of TEOS, 100 µL of NH4OH and 3% of 3-glycidyloxypropyltrimethoxysilane (GPTS). Simultaneously, polyethyleneimine (PEI) was covalently conjugated to GO to enhance the stability of GO in aqueous solutions and create the reaction sites with epoxy groups on the surface of GPTS-coated MNP@SiO2. The ratio of PEI grafted GO and GPTS-coated MNP@SiO2 (GO/MNP ratio) was investigated to produce GO/MNPs@SiO2 with highly saturated magnetization without aggregation. As a result, the GO/MNP ratio of 5 was the best condition to produce the GO/MNP@SiO2 with 9.53 emu/g of saturation superparamagnetization at a magnetic field of 2.0 (T). Finally, the GO/MNPs@SiO2 were used to separate bovine serum albumin (BSA) to investigate its protein isolation ability. The quantity of BSA adsorbed onto 1 mg of GO/MNP@SiO2 increased sharply over time to reach 628 ± 9.3 µg/mg after 15 min, which was 3.5-fold-higher than that of GPTS-coated MNP@SiO2. This result suggests that the GO/MNP@SiO2 nanostructure can be used for protein isolation.
Collapse
Affiliation(s)
- Xuan-Hung Pham
- Department of Bioscience and Biotechnology, Konkuk University, Seoul 05029, Korea; (X.-H.P.); (E.H.); (H.-M.K.); (B.S.S.); (A.J.); (J.A.)
| | - Eunil Hahm
- Department of Bioscience and Biotechnology, Konkuk University, Seoul 05029, Korea; (X.-H.P.); (E.H.); (H.-M.K.); (B.S.S.); (A.J.); (J.A.)
| | - Hyung-Mo Kim
- Department of Bioscience and Biotechnology, Konkuk University, Seoul 05029, Korea; (X.-H.P.); (E.H.); (H.-M.K.); (B.S.S.); (A.J.); (J.A.)
| | - Byung Sung Son
- Department of Bioscience and Biotechnology, Konkuk University, Seoul 05029, Korea; (X.-H.P.); (E.H.); (H.-M.K.); (B.S.S.); (A.J.); (J.A.)
| | - Ahla Jo
- Department of Bioscience and Biotechnology, Konkuk University, Seoul 05029, Korea; (X.-H.P.); (E.H.); (H.-M.K.); (B.S.S.); (A.J.); (J.A.)
| | - Jaehyun An
- Department of Bioscience and Biotechnology, Konkuk University, Seoul 05029, Korea; (X.-H.P.); (E.H.); (H.-M.K.); (B.S.S.); (A.J.); (J.A.)
| | - Tuong An Tran Thi
- Laboratory of Biofuel and Biomass Research, VNU-HCMU University of Technology, 268 Ly Thuong Kiet street, district 10, Ho Chi Minh 700000, Vietnam; (T.A.T.T.); (D.Q.N.)
| | - Dinh Quan Nguyen
- Laboratory of Biofuel and Biomass Research, VNU-HCMU University of Technology, 268 Ly Thuong Kiet street, district 10, Ho Chi Minh 700000, Vietnam; (T.A.T.T.); (D.Q.N.)
| | - Bong-Hyun Jun
- Department of Bioscience and Biotechnology, Konkuk University, Seoul 05029, Korea; (X.-H.P.); (E.H.); (H.-M.K.); (B.S.S.); (A.J.); (J.A.)
| |
Collapse
|
28
|
Li F, Huang Y, Huang K, Lin J, Huang P. Functional Magnetic Graphene Composites for Biosensing. Int J Mol Sci 2020; 21:E390. [PMID: 31936264 PMCID: PMC7013569 DOI: 10.3390/ijms21020390] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2019] [Revised: 12/13/2019] [Accepted: 12/26/2019] [Indexed: 12/14/2022] Open
Abstract
Magnetic graphene composites (MGCs), which are composed of magnetic nanoparticles with graphene or its derivatives, played an important role in sensors development. Due to the enhanced electronic properties and the synergistic effect of magnetic nanomaterials and graphene, MGCs could be used to realize more efficient sensors such as chemical, biological, and electronic sensors, compared to their single component alone. In this review, we first reviewed the various routes for MGCs preparation. Then, sensors based on MGCs were discussed in different groups, including optical sensors, electrochemical sensors, and others. At the end of the paper, the challenges and opportunities for MGCs in sensors implementation are also discussed.
Collapse
Affiliation(s)
| | | | | | | | - Peng Huang
- Marshall Laboratory of Biomedical Engineering, International Cancer Center, Laboratory of Evolutionary Theranostics (LET), School of Biomedical Engineering, Shenzhen University Health Science Center, Shenzhen 518060, China; (F.L.); (Y.H.); (K.H.); (J.L.)
| |
Collapse
|
29
|
Graphene-Based Biosensors for Detection of Biomarkers. MICROMACHINES 2020; 11:mi11010060. [PMID: 31947894 PMCID: PMC7019259 DOI: 10.3390/mi11010060] [Citation(s) in RCA: 75] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 12/23/2019] [Accepted: 12/30/2019] [Indexed: 12/16/2022]
Abstract
The development of biosensors with high sensitivity and low-detection limits provides a new direction for medical and personal care. Graphene and graphene derivatives have been used to prepare various types of biosensors due to their excellent sensing performance (e.g., high specific surface area, extraordinary electronic properties, electron transport capabilities and ultrahigh flexibility). This perspective review focuses on graphene-based biosensors for quantitative detection of cancer-related biomarkers such as DNA, miRNA, small molecules and proteins by integrating with different signal outputting approaches including fluorescent, electrochemistry, surface plasmon resonance, surface enhanced Raman scattering, etc. The article also discussed their challenges and potential solutions along with future prospects.
Collapse
|
30
|
Khanmohammadi A, Aghaie A, Vahedi E, Qazvini A, Ghanei M, Afkhami A, Hajian A, Bagheri H. Electrochemical biosensors for the detection of lung cancer biomarkers: A review. Talanta 2019; 206:120251. [PMID: 31514848 DOI: 10.1016/j.talanta.2019.120251] [Citation(s) in RCA: 162] [Impact Index Per Article: 32.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Revised: 08/08/2019] [Accepted: 08/09/2019] [Indexed: 01/05/2023]
Abstract
Cancer is one of the most widespread challenges and important diseases, which has the highest mortality rate. Lung cancer is the most common type of cancer, so that about 25% of all cancer deaths are related to the lung cancer. The lung cancer is classified as two different types with different treatment methodology: the small cell lung carcinoma and nonsmall cell lung carcinoma are two categories of the lung cancer. Since the lung cancer is often in the latent period in its early stages, therefore, early diagnosis of lung cancer has many challenges. Hence, there is a need for sensitive and reliable tools for preclinical diagnosis of lung cancer. Therefore, many detection methods have been employed for early detection of lung cancer. As lung cancer tumors growth in the body, the cancerous cells release numerous DNA, proteins, and metabolites as special biomarkers of the lung cancer. The levels of these biomarkers show the stages of the lung cancer. Therefore, detection of the biomarkers can be used for screening and clinical diagnosis of the lung cancer. There are numerous biomarkers for the lung cancer such as EGFR, CEA, CYFRA 21-1, ENO1, NSE, CA 19-9, CA 125 and VEGF. Nowadays, electrochemical methods are very attractive and useful in the lung cancer detections. So, in this paper, the recent advances and improvements (2010-2018) in the electrochemical detection of the lung cancer biomarkers have been reviewed.
Collapse
Affiliation(s)
- Akbar Khanmohammadi
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Ali Aghaie
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Ensieh Vahedi
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Ali Qazvini
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Mostafa Ghanei
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Abbas Afkhami
- Faculty of Chemistry, Bu-Ali Sina University, Hamedan, Iran
| | - Ali Hajian
- Institute of Sensor and Actuator Systems, TU Wien, Vienna, Austria
| | - Hasan Bagheri
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
31
|
Panwar N, Soehartono AM, Chan KK, Zeng S, Xu G, Qu J, Coquet P, Yong KT, Chen X. Nanocarbons for Biology and Medicine: Sensing, Imaging, and Drug Delivery. Chem Rev 2019; 119:9559-9656. [DOI: 10.1021/acs.chemrev.9b00099] [Citation(s) in RCA: 238] [Impact Index Per Article: 47.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Nishtha Panwar
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Alana Mauluidy Soehartono
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Kok Ken Chan
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Shuwen Zeng
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore
- CINTRA CNRS/NTU/THALES, UMI 3288, Research Techno Plaza, 50 Nanyang Drive, Border X Block, Singapore 637553, Singapore
| | - Gaixia Xu
- Key Laboratory of Optoelectronics Devices and Systems of Ministry of Education/Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, P. R. China
| | - Junle Qu
- Key Laboratory of Optoelectronics Devices and Systems of Ministry of Education/Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, P. R. China
| | - Philippe Coquet
- CINTRA CNRS/NTU/THALES, UMI 3288, Research Techno Plaza, 50 Nanyang Drive, Border X Block, Singapore 637553, Singapore
- Institut d’Electronique, de Microélectronique et de Nanotechnologie (IEMN), CNRS UMR 8520—Université de Lille, 59650 Villeneuve d’Ascq, France
| | - Ken-Tye Yong
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Xiaoyuan Chen
- Laboratory of Molecular Imaging and Nanomedicine, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, Maryland 20892, United States
| |
Collapse
|
32
|
Abrao Nemeir I, Saab J, Hleihel W, Errachid A, Jafferzic-Renault N, Zine N. The Advent of Salivary Breast Cancer Biomarker Detection Using Affinity Sensors. SENSORS (BASEL, SWITZERLAND) 2019; 19:E2373. [PMID: 31126047 PMCID: PMC6566681 DOI: 10.3390/s19102373] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Revised: 05/09/2019] [Accepted: 05/20/2019] [Indexed: 12/14/2022]
Abstract
Breast Cancer is one of the world's most notorious diseases affecting two million women in 2018 worldwide. It is a highly heterogeneous disease, making it difficult to treat. However, its linear progression makes it a candidate for early screening programs, and the earlier its detection the higher the chance of recovery. However, one key hurdle for breast cancer screening is the fact that most screening techniques are expensive, time-consuming, and cumbersome, making them impractical for use in several parts of the world. One current trend in breast cancer detection has pointed to a possible solution, the use of salivary breast cancer biomarkers. Saliva is an attractive medium for diagnosis because it is readily available in large quantities, easy to obtain at low cost, and contains all the biomarkers present in blood, albeit in lower quantities. Affinity sensors are devices that detect molecules through their interactions with biological recognition molecules. Their low cost, high sensitivity, and selectivity, as well as rapid detection time make them an attractive alternative to traditional means of detection. In this review article, we discuss the current status of breast cancer diagnosis, its salivary biomarkers, as well as the current trends in the development of affinity sensors for their detection.
Collapse
Affiliation(s)
- Imad Abrao Nemeir
- Faculty of Sciences, Holy Spirit University of Kaslik, 446 Jounieh, Mount Lebanon, Lebanon.
- Institut des Sciences Analytiques, Université de Lyon, Claude Bernard Lyon 1, UMR 5280, CNRS - 5, rue de la Doua, 69100 Villeurbanne, France.
| | - Joseph Saab
- Faculty of Sciences, Holy Spirit University of Kaslik, 446 Jounieh, Mount Lebanon, Lebanon.
| | - Walid Hleihel
- Faculty of Sciences, Holy Spirit University of Kaslik, 446 Jounieh, Mount Lebanon, Lebanon.
| | - Abdelhamid Errachid
- Institut des Sciences Analytiques, Université de Lyon, Claude Bernard Lyon 1, UMR 5280, CNRS - 5, rue de la Doua, 69100 Villeurbanne, France.
| | - Nicole Jafferzic-Renault
- Institut des Sciences Analytiques, Université de Lyon, Claude Bernard Lyon 1, UMR 5280, CNRS - 5, rue de la Doua, 69100 Villeurbanne, France.
| | - Nadia Zine
- Institut des Sciences Analytiques, Université de Lyon, Claude Bernard Lyon 1, UMR 5280, CNRS - 5, rue de la Doua, 69100 Villeurbanne, France.
| |
Collapse
|
33
|
Bozal‐Palabiyik B, Lettieri M, Uslu B, Marrazza G. Electrochemical Detection of Vascular Endothelial Growth Factor by Molecularly Imprinted Polymer. ELECTROANAL 2019. [DOI: 10.1002/elan.201900185] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Affiliation(s)
- Burcin Bozal‐Palabiyik
- University of FlorenceDepartment of Chemistry “Ugo Schiff” Via della Lastruccia 3 50019 Sesto Fiorentino Italy
- University of Ankara, Faculty of PharmacyDepartment of Analytical Chemistry 06560 Ankara Turkey
| | - Mariagrazia Lettieri
- University of FlorenceDepartment of Chemistry “Ugo Schiff” Via della Lastruccia 3 50019 Sesto Fiorentino Italy
| | - Bengi Uslu
- University of Ankara, Faculty of PharmacyDepartment of Analytical Chemistry 06560 Ankara Turkey
| | - Giovanna Marrazza
- University of FlorenceDepartment of Chemistry “Ugo Schiff” Via della Lastruccia 3 50019 Sesto Fiorentino Italy
| |
Collapse
|
34
|
Xu M, Yadavalli VK. Flexible Biosensors for the Impedimetric Detection of Protein Targets Using Silk-Conductive Polymer Biocomposites. ACS Sens 2019; 4:1040-1047. [PMID: 30957494 DOI: 10.1021/acssensors.9b00230] [Citation(s) in RCA: 50] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
To expand the applications of flexible biosensors in point-of-care healthcare applications beyond monitoring of biophysical parameters, it is important to devise strategies for the detection of various proteins and biomarkers. Here, we demonstrate a flexible, fully organic, biodegradable, label-free impedimetric biosensor for the critical biomarker, vascular endothelial growth factor (VEGF). This biosensor was constructed by photolithographically patterning a conducting ink consisting of a photoreactive silk sericin coupled with a conducting polymer. These functional electrodes are printed on flexible fibroin substrates that are controllably thick and can be free-standing, or conform to soft surfaces. Detection was accomplished via the antibody to VEGF which was immobilized within the conducting matrix. The results indicated that the developed flexible biosensor was highly sensitive and selective to the target protein, even in challenging biofluids such as human serum. The biosensors themselves are biocompatible and degradable. Through this work, the developed flexible biosensor based on a simple and label-free strategy can find practical applications in the monitoring of wound healing or early disease diagnosis.
Collapse
Affiliation(s)
- Meng Xu
- Department of Chemical and Life Science Engineering, Virginia Commonwealth University, 601 W. Main Street, Richmond, Virginia 23284, United States
| | - Vamsi K. Yadavalli
- Department of Chemical and Life Science Engineering, Virginia Commonwealth University, 601 W. Main Street, Richmond, Virginia 23284, United States
| |
Collapse
|
35
|
Development of a Sandwich Immunosensor for concurrent detection of carcinoembryonic antigen (CEA), vascular endothelial growth factor (VEGF) and α-fetoprotein (AFP) biomarkers. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 101:88-91. [PMID: 31029367 DOI: 10.1016/j.msec.2019.03.079] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Revised: 02/22/2019] [Accepted: 03/22/2019] [Indexed: 01/01/2023]
Abstract
Cancer Biomarkers are important biological molecules which provide early detection, diagnosis and classification of cancer cells. In this work, nanoparticle tags with different redox potentials have been used as an electrochemical coding technology for the simultaneous detection of carcinoembryonic antigen (CEA), vascular endothelial growth factor (VEGF) and α-fetoprotein (AFP) biomarkers. As far as we know, this is the only work that covers the simultaneous detections of these biomarkers. For this purpose, basically, an electrochemical sandwich immunosensor, which was fabricated from carbon screen printed electrode, was utilized as a diagnostic platform. As nanoparticle tags, PbAu@ɣFe2O3, CuAu@ɣFe2O3 and ZnAu@ɣFe2O3 hybrid nanolabels were synthesized and used for labelling anti-CEA, anti-VEGF and anti-AFP, respectively. By monitoring differential pulse voltammetric oxidation peaks of labeling metals (Pb, Cu, Zn), CEA, VEGF and AFP biomarkers were detected at the same time.
Collapse
|
36
|
Zhou Q, Yan B, Xing T, Chen G. Fabrication of superhydrophobic caffeic acid/Fe@cotton fabric and its oil-water separation performance. Carbohydr Polym 2019; 203:1-9. [PMID: 30318191 DOI: 10.1016/j.carbpol.2018.09.025] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2018] [Revised: 09/05/2018] [Accepted: 09/13/2018] [Indexed: 10/28/2022]
|
37
|
Vlăsceanu GM, Amărandi RM, Ioniță M, Tite T, Iovu H, Pilan L, Burns JS. Versatile graphene biosensors for enhancing human cell therapy. Biosens Bioelectron 2018; 117:283-302. [DOI: 10.1016/j.bios.2018.04.053] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Revised: 04/18/2018] [Accepted: 04/25/2018] [Indexed: 01/04/2023]
|
38
|
Amărandi RM, Becheru DF, Vlăsceanu GM, Ioniță M, Burns JS. Advantages of Graphene Biosensors for Human Stem Cell Therapy Potency Assays. BIOMED RESEARCH INTERNATIONAL 2018; 2018:1676851. [PMID: 30003089 PMCID: PMC5996421 DOI: 10.1155/2018/1676851] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/27/2017] [Accepted: 03/22/2018] [Indexed: 12/11/2022]
Abstract
Regenerative medicine is challenged by the need to conform to rigorous guidelines for establishing safe and effective development and translation of stem cell-based therapies. Counteracting widespread concerns regarding unproven cell therapies, stringent cell-based assays seek not only to avoid harm but also to enhance quality and efficacy. Potency indicates that the cells are functionally fit for purpose before they are administered to the patient. It is a paramount quantitative critical quality attribute serving as a decisive release criterion. Given a broad range of stem cell types and therapeutic contexts the potency assay often comprises one of the most demanding hurdles for release of a cell therapy medicinal product. With need for improved biomarker assessment and expedited measurement, recent advances in graphene-based biosensors suggest that they are poised to be valuable platforms for accelerating potency assay development. Among several potential advantages, they offer versatility for sensitive measurement of a broad range of potential biomarker types, cell biocompatibility for direct measurement, and small sample sufficiency, plus ease of use and point-of-care applicability.
Collapse
Affiliation(s)
- Roxana-Maria Amărandi
- Faculty of Medical Engineering, University Politehnica of Bucharest, Gh. Polizu 1-7, 011061 Bucharest, Romania
| | - Diana F. Becheru
- Faculty of Medical Engineering, University Politehnica of Bucharest, Gh. Polizu 1-7, 011061 Bucharest, Romania
| | - George M. Vlăsceanu
- Faculty of Medical Engineering, University Politehnica of Bucharest, Gh. Polizu 1-7, 011061 Bucharest, Romania
| | - Mariana Ioniță
- Faculty of Medical Engineering, University Politehnica of Bucharest, Gh. Polizu 1-7, 011061 Bucharest, Romania
- Advanced Polymer Materials Group, University Politehnica of Bucharest, Gh. Polizu 1-7, 011061 Bucharest, Romania
| | - Jorge S. Burns
- Faculty of Medical Engineering, University Politehnica of Bucharest, Gh. Polizu 1-7, 011061 Bucharest, Romania
- Department of Medical and Surgical Sciences of Children and Adults, University Hospital of Modena and Reggio Emilia, Modena, Italy
| |
Collapse
|
39
|
Graphene oxide: An efficient material and recent approach for biotechnological and biomedical applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2018. [DOI: 10.1016/j.msec.2018.01.004] [Citation(s) in RCA: 164] [Impact Index Per Article: 27.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
40
|
Koo MA, Lee MH, Kwon BJ, Seon GM, Kim MS, Kim D, Nam KC, Park JC. Exogenous ROS-induced cell sheet transfer based on hematoporphyrin-polyketone film via a one-step process. Biomaterials 2018; 161:47-56. [DOI: 10.1016/j.biomaterials.2018.01.030] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Revised: 01/15/2018] [Accepted: 01/19/2018] [Indexed: 12/14/2022]
|
41
|
Crulhas BP, Karpik AE, Delella FK, Castro GR, Pedrosa VA. Electrochemical aptamer-based biosensor developed to monitor PSA and VEGF released by prostate cancer cells. Anal Bioanal Chem 2017; 409:6771-6780. [PMID: 29032455 DOI: 10.1007/s00216-017-0630-1] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2017] [Revised: 08/30/2017] [Accepted: 09/07/2017] [Indexed: 11/21/2022]
Abstract
Early prostate cancer (PCa) diagnostic is crucial to enhance patient survival rates; besides, non-invasive platforms have been developed worldwide in order to precisely detect PCa biomarkers. Therefore, the aim of the present study is to develop a new aptamer-based biosensor through the self-assembling of thiolated aptamers for PSA and VEGF on the top of gold electrodes. This biosensor was tested in three prostate cell lines (RWPE-1, LNCaP and PC3). The results evidenced a stable and sensitive sensor presenting wide linear detection ranges (0.08-100 ng/mL for PSA and 0.15 ng-100 ng/mL for VEGF). Therefore, the aptasensor was able to detect the patterns of PSA and VEGF released in vitro by PCa cells, which gave new insights about the prostate cancer protein dynamics. Thus, it could be used as a non-invasive PCa clinical diagnosis instrument in the near future. Graphical Abstract Overview of the experimental design applied to the aptamer-based electrochemical sensor self-assembled on the thiolated hairpin structure. A filter membrane was added on top of working electrode to provide the cell-attachment surface after aptamer incubation, without compromising the aptamer layer. The pore membrane allowed target proteins to pass to the aptamer surface; the MCH backfilling avoided unspecific protein binding to the gold electrode surface.
Collapse
Affiliation(s)
- Bruno P Crulhas
- Department of Chemistry and Biochemistry, Institute of Bioscience, UNESP-Botucatu, Distrito de Rubiao Jr, 18618-000 Botucatu, São Paulo, 18618-000, Brazil
| | - Agnieszka E Karpik
- Department of Chemistry and Biochemistry, Institute of Bioscience, UNESP-Botucatu, Distrito de Rubiao Jr, 18618-000 Botucatu, São Paulo, 18618-000, Brazil
| | - Flávia K Delella
- Department of Chemistry and Biochemistry, Institute of Bioscience, UNESP-Botucatu, Distrito de Rubiao Jr, 18618-000 Botucatu, São Paulo, 18618-000, Brazil
| | - Gustavo R Castro
- Department of Chemistry and Biochemistry, Institute of Bioscience, UNESP-Botucatu, Distrito de Rubiao Jr, 18618-000 Botucatu, São Paulo, 18618-000, Brazil
| | - Valber A Pedrosa
- Department of Chemistry and Biochemistry, Institute of Bioscience, UNESP-Botucatu, Distrito de Rubiao Jr, 18618-000 Botucatu, São Paulo, 18618-000, Brazil.
| |
Collapse
|
42
|
Al-Ani LA, AlSaadi MA, Kadir FA, Hashim NM, Julkapli NM, Yehye WA. Graphene- gold based nanocomposites applications in cancer diseases; Efficient detection and therapeutic tools. Eur J Med Chem 2017; 139:349-366. [PMID: 28806615 DOI: 10.1016/j.ejmech.2017.07.036] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2017] [Revised: 07/07/2017] [Accepted: 07/20/2017] [Indexed: 01/09/2023]
Abstract
Early detection and efficient treatment of cancer disease remains a drastic challenge in 21st century. Throughout the bulk of funds, studies, and current therapeutics, cancer seems to aggressively advance with drug resistance strains and recurrence rates. Nevertheless, nanotechnologies have indeed given hope to be the next generation for oncology applications. According to US National cancer institute, it is anticipated to revolutionize the perspectives of cancer diagnosis and therapy. With such success, nano-hybrid strategy creates a marvelous preference. Herein, graphene-gold based composites are being increasingly studied in the field of oncology, for their outstanding performance as robust vehicle of therapeutic agents, built-in optical diagnostic features, and functionality as theranostic system. Additional modes of treatments are also applicable including photothermal, photodynamic, as well as combined therapy. This review aims to demonstrate the various cancer-related applications of graphene-gold based hybrids in terms of detection and therapy, highlighting the major attributes that led to designate such system as a promising ally in the war against cancer.
Collapse
Affiliation(s)
- Lina A Al-Ani
- Institute of Postgraduate Studies Building, Nanotechnology & Catalysis Research Centre (NANOCAT), University of Malaya, Kuala Lumpur 50603, Malaysia
| | - Mohammed A AlSaadi
- Institute of Postgraduate Studies Building, Nanotechnology & Catalysis Research Centre (NANOCAT), University of Malaya, Kuala Lumpur 50603, Malaysia; University of Malaya Centre for Ionic Liquids (UMCiL), University of Malaya, 50603 Kuala Lumpur, Malaysia
| | - Farkaad A Kadir
- Division of Human Biology, Faculty of Medicine, International Medical University, 57000 Kuala Lumpur, Malaysia
| | - Najihah M Hashim
- Department of Pharmacy, Faculty of Medicine, University of Malaya, 50603 Kuala Lumpur, Malaysia; Centre for Natural Products and Drug Discovery (CENAR), University of Malaya, 50603 Kuala Lumpur, Malaysia
| | - Nurhidayatullaili M Julkapli
- Institute of Postgraduate Studies Building, Nanotechnology & Catalysis Research Centre (NANOCAT), University of Malaya, Kuala Lumpur 50603, Malaysia.
| | - Wageeh A Yehye
- Institute of Postgraduate Studies Building, Nanotechnology & Catalysis Research Centre (NANOCAT), University of Malaya, Kuala Lumpur 50603, Malaysia.
| |
Collapse
|
43
|
Scherf KA, Ciccocioppo R, Pohanka M, Rimarova K, Opatrilova R, Rodrigo L, Kruzliak P. Biosensors for the Diagnosis of Celiac Disease: Current Status and Future Perspectives. Mol Biotechnol 2017; 58:381-92. [PMID: 27130174 DOI: 10.1007/s12033-016-9940-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Celiac disease (CD) is an autoimmune enteropathy initiated and sustained by the ingestion of gluten in genetically susceptible individuals. It is caused by a dysregulated immune response toward both dietary antigens, the gluten proteins of wheat, rye, and barley, and autoantigens, the enzyme tissue transglutaminase (TG2). The small intestine is the target organ. Although routine immunochemical protocols for a laboratory diagnosis of CD are available, faster, easier-to-use, and cheaper analytical devices for CD diagnosis are currently unavailable. This review focuses on biosensors, consisting of a physicochemical transducer and a bioreceptor, as promising analytical tools for diagnosis of CD and other diseases. Examples of recently developed biosensors as well as expectations for future lines of research and development in this field are presented.
Collapse
Affiliation(s)
| | - Rachele Ciccocioppo
- Clinica Medica I, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy
| | - Miroslav Pohanka
- Faculty of Military Health Sciences, University of Defence, Hradec Kralove, Czech Republic
| | - Kvetoslava Rimarova
- Department of Public Health and Hygiene, Faculty of Medicine, Pavol Jozef Safarik University, Kosice, Slovakia
| | - Radka Opatrilova
- Department of Chemical Drugs, Faculty of Pharmacy, University of Veterinary and Pharmaceutical Sciences, Brno, Czech Republic
| | - Luis Rodrigo
- Department of Gastroenterology, Central University Hospital of Asturias (HUCA), Oviedo, Spain
| | - Peter Kruzliak
- Laboratory of Structural Biology and Proteomics, Faculty of Pharmacy, University of Veterinary and Pharmaceutical Sciences, Palackeho tr 1946/1, 612 42, Brno, Czech Republic.
| |
Collapse
|
44
|
The application of graphene for in vitro and in vivo electrochemical biosensing. Biosens Bioelectron 2017; 89:224-233. [DOI: 10.1016/j.bios.2016.03.026] [Citation(s) in RCA: 61] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2015] [Revised: 02/22/2016] [Accepted: 03/13/2016] [Indexed: 01/22/2023]
|
45
|
Pan LH, Kuo SH, Lin TY, Lin CW, Fang PY, Yang HW. An electrochemical biosensor to simultaneously detect VEGF and PSA for early prostate cancer diagnosis based on graphene oxide/ssDNA/PLLA nanoparticles. Biosens Bioelectron 2017; 89:598-605. [DOI: 10.1016/j.bios.2016.01.077] [Citation(s) in RCA: 133] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2015] [Revised: 12/28/2015] [Accepted: 01/28/2016] [Indexed: 01/26/2023]
|
46
|
Jayanthi VSPKSA, Das AB, Saxena U. Recent advances in biosensor development for the detection of cancer biomarkers. Biosens Bioelectron 2016; 91:15-23. [PMID: 27984706 DOI: 10.1016/j.bios.2016.12.014] [Citation(s) in RCA: 245] [Impact Index Per Article: 30.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Revised: 11/24/2016] [Accepted: 12/07/2016] [Indexed: 02/08/2023]
Abstract
Cancer is the second largest disease throughout the world with an increasing mortality rate over the past few years. The patient's survival rate is uncertain due to the limitations of cancer diagnosis and therapy. Early diagnosis of cancer is decisive for its successful treatment. A biomarker-based cancer diagnosis may significantly improve the early diagnosis and subsequent treatment. Biosensors play a crucial role in the detection of biomarkers as they are easy to use, portable, and can do analysis in real time. This review describes various biosensors designed for detecting nucleic acid and protein-based cancer biomarkers for cancer diagnosis. It mainly lays emphasis on different approaches to use electrochemical, optical, and mass-based transduction systems in cancer biomarker detection. It also highlights the analytical performances of various biosensor designs concerning cancer biomarkers in detail.
Collapse
Affiliation(s)
| | - Asim Bikas Das
- Department of Biotechnology, National Institute of Technology Warangal, Warangal 506004, Telangana, India
| | - Urmila Saxena
- Department of Biotechnology, National Institute of Technology Warangal, Warangal 506004, Telangana, India.
| |
Collapse
|
47
|
Wang Y, Liu Y, Deng X, Cong Y, Jiang X. Peptidic β-sheet binding with Congo Red allows both reduction of error variance and signal amplification for immunoassays. Biosens Bioelectron 2016; 86:211-218. [DOI: 10.1016/j.bios.2016.06.021] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2016] [Revised: 06/01/2016] [Accepted: 06/08/2016] [Indexed: 01/08/2023]
|
48
|
Yang HW, Tsai RY, Chen JP, Ju SP, Liao JF, Wei KC, Zou WL, Hua MY. Fabrication of a Nanogold-Dot Array for Rapid and Sensitive Detection of Vascular Endothelial Growth Factor in Human Serum. ACS APPLIED MATERIALS & INTERFACES 2016; 8:30845-30852. [PMID: 27768268 DOI: 10.1021/acsami.6b13329] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A simple and accurate device for early detection of malignancies is paramount for prompt treatment and prevention of metastases. In this study, we describe a novel fabrication method for producing an ordered nanogold-dot array with strong localized surface plasmon resonance (LSPR) and narrow bandwidth. The array was used as an optical biosensing chip for the detection of vascular endothelial growth factor 165 (VEGF165) in human serum. The biochip was constructed by conjugating an anti-VEGF antibody, a specific biorecognition element for VEGF165, onto the array via the fragment crystallizable (Fc) region of the antibody, ultimately increasing the efficiency of VEGF165 detection. The resulting biochip was sensitive, had a wide linear detection range (0.01-100 ng/mL), was specific for VEGF165 (showing no interference when challenged with glucose and ascorbic acid), and characterized by an excellent stability (allowing storage and transportation at room temperature). Owing to the good correlations of VEGF165 measurements obtained with ELISA, we believe that our chip holds promise as a tool for early diagnosis of cancer.
Collapse
Affiliation(s)
| | - Rung-Ywan Tsai
- Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute , Hsin-chu 31040, Taiwan
| | - Jung-Po Chen
- Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute , Hsin-chu 31040, Taiwan
| | - Shin-Pon Ju
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University , Kaohsiung 80708, Taiwan
| | | | - Kuo-Chen Wei
- Department of Neurosurgery, Chang Gung Memorial Hospital and Chang Gung University , Tao-Yuan 33302, Taiwan
| | - Wei-Lun Zou
- Department of Chemical and Materials Engineering, Chang Gung University , Tao-Yuan 33302, Taiwan
| | - Mu-Yi Hua
- Department of Neurosurgery, Chang Gung Memorial Hospital and Chang Gung University , Tao-Yuan 33302, Taiwan
- Department of Chemical and Materials Engineering, Chang Gung University , Tao-Yuan 33302, Taiwan
| |
Collapse
|
49
|
Ranjan R, Esimbekova EN, Kratasyuk VA. Rapid biosensing tools for cancer biomarkers. Biosens Bioelectron 2016; 87:918-930. [PMID: 27664412 DOI: 10.1016/j.bios.2016.09.061] [Citation(s) in RCA: 88] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Revised: 09/06/2016] [Accepted: 09/17/2016] [Indexed: 12/14/2022]
Abstract
The present review critically discusses the latest developments in the field of smart diagnostic systems for cancer biomarkers. A wide coverage of recent biosensing approaches involving aptamers, enzymes, DNA probes, fluorescent probes, interacting proteins and antibodies in vicinity to transducers such as electrochemical, optical and piezoelectric is presented. Recent advanced developments in biosensing approaches for cancer biomarker owes much credit to functionalized nanomaterials due to their unique opto-electronic properties and enhanced surface to volume ratio. Biosensing methods for a plenty of cancer biomarkers has been summarized emphasizing the key principles involved.
Collapse
Affiliation(s)
- Rajeev Ranjan
- Laboratory of Bioluminescent Biotechnologies, Department of Biophysics, Institute of Fundamental Biology and Biotechnology, Siberian Federal University, 79 Svobodny prospect, Krasnoyarsk 660041, Russia
| | - Elena N Esimbekova
- Laboratory of Bioluminescent Biotechnologies, Department of Biophysics, Institute of Fundamental Biology and Biotechnology, Siberian Federal University, 79 Svobodny prospect, Krasnoyarsk 660041, Russia; Institute of Biophysics SB RAS, Akademgorodok 50/50, Krasnoyarsk 660036, Russia.
| | - Valentina A Kratasyuk
- Laboratory of Bioluminescent Biotechnologies, Department of Biophysics, Institute of Fundamental Biology and Biotechnology, Siberian Federal University, 79 Svobodny prospect, Krasnoyarsk 660041, Russia; Institute of Biophysics SB RAS, Akademgorodok 50/50, Krasnoyarsk 660036, Russia
| |
Collapse
|
50
|
Liu Z, Wang Y, Deng R, Yang L, Yu S, Xu S, Xu W. Fe3O4@Graphene Oxide@Ag Particles for Surface Magnet Solid-Phase Extraction Surface-Enhanced Raman Scattering (SMSPE-SERS): From Sample Pretreatment to Detection All-in-One. ACS APPLIED MATERIALS & INTERFACES 2016; 8:14160-14168. [PMID: 27191584 DOI: 10.1021/acsami.6b02944] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
A multifunctional magnetic graphene surface-enhanced Raman scattering (SERS) substrate was fabricated successfully by the layer-by-layer assembly of silver and graphene oxide (GO) nanoparticles (NPs) on the magnetic ferroferric oxide particles (Fe3O4@GO@Ag). This ternary particle possesses magnetic properties, SERS activity, and adsorption ability simultaneously. Owing to the multifunction of this Fe3O4@GO@Ag ternary complex, we put forward a new method called a surface magnetic solid-phase extraction (SMSPE) technique, for the SERS detections of pesticide residues on the fruit peels. SMSPE integrates many sample pretreatment procedures, such as surface extraction, separation sample, and detection, all-in-one. So this method shows great superiority in simplicity, rapidity, and high efficiency above other standard methods. The whole detection process can be finished within 20 min including the sample pretreatment and SERS detection. Owing to the high density of Ag NPs, the detection sensitivity is high enough that the lowest detectable concentrations are 0.48 and 40 ng/cm(2) for thiram and thiabendazole, which are much lower than the maximal residue limits in fruit prescribed by the U.S. Environmental Protection Agency. This multifunctional ternary particle and its corresponding analytical method have been proven to be applicable for practical samples and also valuable for other surface analysis.
Collapse
Affiliation(s)
- Zhigang Liu
- State Key Laboratory of Supramolecular Structure and Materials, Institute of Theoretical Chemistry, Jilin University , 2699 Qianjin Avenue, Changchun 130012 China
- Centre of Analysis and Measurement, Jilin Institute of Chemical Technology , Jilin 132022 China
| | - Yi Wang
- State Key Laboratory of Supramolecular Structure and Materials, Institute of Theoretical Chemistry, Jilin University , 2699 Qianjin Avenue, Changchun 130012 China
| | - Rong Deng
- State Key Laboratory of Supramolecular Structure and Materials, Institute of Theoretical Chemistry, Jilin University , 2699 Qianjin Avenue, Changchun 130012 China
| | - Liyuan Yang
- State Key Laboratory of Supramolecular Structure and Materials, Institute of Theoretical Chemistry, Jilin University , 2699 Qianjin Avenue, Changchun 130012 China
| | - Shihua Yu
- State Key Laboratory of Supramolecular Structure and Materials, Institute of Theoretical Chemistry, Jilin University , 2699 Qianjin Avenue, Changchun 130012 China
- Centre of Analysis and Measurement, Jilin Institute of Chemical Technology , Jilin 132022 China
| | - Shuping Xu
- State Key Laboratory of Supramolecular Structure and Materials, Institute of Theoretical Chemistry, Jilin University , 2699 Qianjin Avenue, Changchun 130012 China
| | - Weiqing Xu
- State Key Laboratory of Supramolecular Structure and Materials, Institute of Theoretical Chemistry, Jilin University , 2699 Qianjin Avenue, Changchun 130012 China
| |
Collapse
|