1
|
Jangannanavar VD, Basavanagoudra H, Matteppanavar S, Vaddar H, Nagarajappa H, Patil MK, Inamdar SR, Goudar KM. Honey-Mediated CeO 2 Nanoparticles: A Cost-Effective Approach for Electrochemical Biosensing of Human Serum Albumin. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2025; 41:9239-9255. [PMID: 40189845 DOI: 10.1021/acs.langmuir.4c04940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/16/2025]
Abstract
Human serum albumin (HSA), the most abundant blood plasma protein, is a vital biomarker for diagnosing various health conditions. This study introduces a green and innovative approach for synthesizing CeO2 nanoparticles (NPs) using natural honey as a reducing and stabilizing agent. Comprehensive spectroscopic characterization revealed that the synthesized CeO2 NPs possess a spongy cobblestone morphology (∼13 nm) and an optical bandgap of 3.51 eV. Electrochemical properties were examined using cyclic voltammetry (CV), while UV-visible absorption spectroscopy and electrochemical analyses provided detailed insights into the nano-bio interactions between CeO2 NPs and HSA, highlighting the kinetics of protein adsorption and the bioreactivity of the NPs. The optical binding interactions achieved a low limit of detection (LOD) of 3.42 nM, demonstrating exceptional sensitivity to HSA at trace concentrations. CeO2 NPs were incorporated onto glassy carbon (GCE) and graphite electrodes to fabricate advanced biosensors. Both electrodes exhibited excellent selectivity, linear response ranges, and low detection limits of 2.09 nM (GCE) and 3.3 nM (graphite) for HSA detection. Interference studies confirmed minimal signal variation (±5%) in the presence of common interferents, demonstrating robust anti-interference capabilities. Notably, the CeO2-modified graphite electrode offers a cost-effective alternative with performance comparable to that of the conventional GCE. Electrochemical sensing was further validated using authentic blood serum (BS) samples, confirming its reliability in real-world applications. The biosensor's repeatability, reproducibility, and long-term stability were also assessed, demonstrating consistent performance in biological matrices. Therefore, this work establishes CeO2-modified electrodes as highly sensitive, selective, and economical platforms for real-time HSA detection. The findings hold significant promise for advancing biosensor technologies with broad applications in clinical diagnostics, environmental monitoring, and next-generation sensing systems.
Collapse
Affiliation(s)
| | | | - Shidaling Matteppanavar
- Department of Physics, KLE Society's Basavaprabhu Kore Arts, Science and Commerce College, Chikodi, Karnataka 591 201, India
| | - Husenappa Vaddar
- Department of Physics, Vijayanagara Sri Krishnadevaraya University, Ballari 583 105, Karnataka, India
- Department of Physics, B. V. V. S. Basaveshwar Science College, Bagalakote, Karnataka 587 101, India
| | | | - Mallikarjun K Patil
- Laser Spectroscopy Programme, Department of Physics, Karnatak University, Dharwad 580 003, Karnataka, India
| | - Sanjeev R Inamdar
- Laser Spectroscopy Programme, Department of Physics, Karnatak University, Dharwad 580 003, Karnataka, India
| | - Kotresh M Goudar
- Department of Physics, Vijayanagara Sri Krishnadevaraya University, Ballari 583 105, Karnataka, India
| |
Collapse
|
2
|
Nan X, Wu Y, Xu L, Yang L, Cui Y. A novel glass chip based lateral flow immunoassay of albumin. Biomed Microdevices 2025; 27:15. [PMID: 40138001 DOI: 10.1007/s10544-025-00744-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/12/2025] [Indexed: 03/29/2025]
Abstract
Lateral flow immunoassays typically rely on optical tests conducted on paper strips. However, the 3D matrix of paper embedded with optical nanoparticles often limits detection sensitivity and the ability of detection instruments to capture signals. This study introduces a novel approach using a glass chip-based lateral flow immunoassay, with albumin as a typical biomarker for detection, enabling the presence of the signal on a flat surface. Compared with traditional paper-based immunoassay, glass-based lateral flow immunoassay has achieved a uniform distribution pattern for albumin detection, lowered the limit of detection from 100 ng/mL to 1 ng/mL, and reduced detection time through an improved liquid mobility system. The glass-based method also shortens the detection time by 28.5% to 147.8 s compared to the traditional method. This research presents a new methodology for lateral flow immunoassays that can be applied to a wide range of biomarkers, with potential benefits for various medical and environmental applications.
Collapse
Affiliation(s)
- Xuanxu Nan
- School of Materials Science and Engineering, Peking University, Beijing, 100871, P.R. China
- Peking University Institute of Nephrology, Beijing, 100034, P.R. China
- Key Laboratory of Renal Disease, Ministry of Health of China, Beijing, 100034, P.R. China
- Key Laboratory of Chronic Kidney Disease Prevention and Treatment (Peking University), Ministry of Education, Beijing, 100034, P.R. China
| | - Yiyang Wu
- School of Materials Science and Engineering, Peking University, Beijing, 100871, P.R. China
- Peking University Institute of Nephrology, Beijing, 100034, P.R. China
- Key Laboratory of Renal Disease, Ministry of Health of China, Beijing, 100034, P.R. China
- Key Laboratory of Chronic Kidney Disease Prevention and Treatment (Peking University), Ministry of Education, Beijing, 100034, P.R. China
| | - Lingyi Xu
- Renal Division, Peking University First Hospital, Beijing, 100034, P.R. China
- Peking University Institute of Nephrology, Beijing, 100034, P.R. China
- Key Laboratory of Renal Disease, Ministry of Health of China, Beijing, 100034, P.R. China
- Key Laboratory of Chronic Kidney Disease Prevention and Treatment (Peking University), Ministry of Education, Beijing, 100034, P.R. China
| | - Li Yang
- Renal Division, Peking University First Hospital, Beijing, 100034, P.R. China.
- Peking University Institute of Nephrology, Beijing, 100034, P.R. China.
- Key Laboratory of Renal Disease, Ministry of Health of China, Beijing, 100034, P.R. China.
- Key Laboratory of Chronic Kidney Disease Prevention and Treatment (Peking University), Ministry of Education, Beijing, 100034, P.R. China.
| | - Yue Cui
- School of Materials Science and Engineering, Peking University, Beijing, 100871, P.R. China.
- Peking University Institute of Nephrology, Beijing, 100034, P.R. China.
- Key Laboratory of Renal Disease, Ministry of Health of China, Beijing, 100034, P.R. China.
- Key Laboratory of Chronic Kidney Disease Prevention and Treatment (Peking University), Ministry of Education, Beijing, 100034, P.R. China.
| |
Collapse
|
3
|
Ding BW, Sang RX, Li XY, Fan J, Tian Y, Ma Y, Xie CZ, Xu JY, Feng YK. A self-assembled fluorescent nanoprobe recognized by FA1 site for specifically selecting HSA: Its applications in hemin detection, cell imaging and fluorescent tracing drug delivery. Bioorg Chem 2025; 154:108120. [PMID: 39753041 DOI: 10.1016/j.bioorg.2024.108120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2024] [Revised: 12/29/2024] [Accepted: 12/30/2024] [Indexed: 01/15/2025]
Abstract
As naturally essential biomacromolecule, HSA has become diagnostic indicators for various diseases and universal carriers for anticancer drug delivery, therefore, fluorescence detection and labeling for HSA possess significant application value in the biomedical field. In this paper, hydrazide Schiff base fluorescent probe NDQC was designed and synthesized, which self-assembled into nanoparticles in aqueous solution system and demonstrated excellent selectivity and sensitivity towards HSA. Through displacement assay and molecular docking simulation, the binding of NDQC with HSA in FA1 site was demonstrated, thereby no obvious fluorescence signal presented for homologous protein BSA due to their structural differences in binding site. Non-toxic probe NDQC is suitable for the fluorescence imaging of HSA in cells, and colocalization fluorescence images showed that NDQC-HSA could illuminate mitochondria. Based on the pH sensitivity of fluorescence emission for NDQC-HSA, discrimination of cancer cells and normal cells could be achieved. For practical applications, NDQC-HSA can be employed to measure the content of hemin. More importantly, NDQC could fluorescently label HSA and therefore NDQC-HSA complex act as the carrier for loading cisplatin. The present findings demonstrate that the probe NDQC has potential in exploring HSA at cellular levels and hold great promise in application of tracking drug-loading nanoparticles.
Collapse
Affiliation(s)
- Bo-Wen Ding
- Pancreas Center, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, State Key Laboratory of Druggability Evaluation and Systematic Translational Medicine, Tianjin Key Laboratory of Digestive Cancer, Tianjin's Clinical Research Center for Cancer, Tianjin 300060, China; Department of Breast Oncoplastic and reconstructive Surgery, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin's Clinical Research Center for Cancer, Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin Medical University, Ministry of Education, Tianjin 300060, China
| | - Ruo-Xi Sang
- Department of Chemical Biology and Tianjin Key Laboratory of Technologies Enabling Development of Clinical Therapeutics and Diagnostics, School of Pharmacy, Tianjin Medical University, Tianjin 300070, China
| | - Xiao-Yu Li
- Department of Chemical Biology and Tianjin Key Laboratory of Technologies Enabling Development of Clinical Therapeutics and Diagnostics, School of Pharmacy, Tianjin Medical University, Tianjin 300070, China; State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), Guangxi Normal University, Guilin 541004, China
| | - Jing Fan
- Department of Chemical Biology and Tianjin Key Laboratory of Technologies Enabling Development of Clinical Therapeutics and Diagnostics, School of Pharmacy, Tianjin Medical University, Tianjin 300070, China
| | - Yu Tian
- Institute of Medicinal Plant Development, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing 100193, China
| | - Ying Ma
- Department of Chemical Biology and Tianjin Key Laboratory of Technologies Enabling Development of Clinical Therapeutics and Diagnostics, School of Pharmacy, Tianjin Medical University, Tianjin 300070, China
| | - Cheng-Zhi Xie
- Department of Chemical Biology and Tianjin Key Laboratory of Technologies Enabling Development of Clinical Therapeutics and Diagnostics, School of Pharmacy, Tianjin Medical University, Tianjin 300070, China; State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), Guangxi Normal University, Guilin 541004, China.
| | - Jing-Yuan Xu
- Department of Chemical Biology and Tianjin Key Laboratory of Technologies Enabling Development of Clinical Therapeutics and Diagnostics, School of Pharmacy, Tianjin Medical University, Tianjin 300070, China.
| | - Yu-Kuan Feng
- Pancreas Center, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, State Key Laboratory of Druggability Evaluation and Systematic Translational Medicine, Tianjin Key Laboratory of Digestive Cancer, Tianjin's Clinical Research Center for Cancer, Tianjin 300060, China.
| |
Collapse
|
4
|
Reddy SM, Stephen AN, Holden MA, Stockburn WJ, Dennison SR. Magnetic nanoparticle-facilitated rapid mass production of high affinity polymeric materials (nanoMIPs) for protein recognition and biosensing. Biomater Sci 2024; 12:5845-5855. [PMID: 39420810 DOI: 10.1039/d4bm00990h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2024]
Abstract
Molecularly imprinted polymers (MIPs) have been investigated extensively for broad applications in diagnostics, imaging and therapeutics due to their antibody-like specificity, high stability, and low-cost and rapid production when compared with biological antibodies. Yet, their wide-scale adoption and commercial viability are limited due to low yields and relatively lengthy preparations of current methods. We report the novel application of protein-functionalised magnetic nanoparticles (MNPs) to enable the rapid mass production of nanoMIPs for protein recognition. An aldehyde-functionalised MNP (MNP@CHO) precursor was synthesised using a one-pot microwave method in less than 20 minutes, resulting in 330 mg yield for a 30 mL reaction volume. The MNP@CHO precursor (10 mg) was subsequently functionalised with 600 μg of a target template protein, giving MNP@protein. In the presence of an N-hydroxymethylacrylamide (NHMA) functional monomer and N,N'-methylene bisacrylamide as a crosslinker, the MNP@protein particles served as nucleants for the mass production of nanoMIPs in a 20-30 minute synthesis process. Subsequently, the nanoMIPs could be harvested with sonication and then retrieved using a magnet, leaving the MNP@protein particles to be recycled and re-used at least 5 times for further nanoMIP production cycles. In general, 10 mg of MNP@protein produced 10 mg of nanoMIP with a 20% decrease in the yield over the 5 synthesis cycles. For the bovine haemoglobin nanoMIP, the KD was determined to be 3.47 × 10-11 M, a binding affinity rivalling values found for monoclonal antibodies. We also demonstrate that the methodology is generic by producing high-affinity nanoMIPs for other proteins including albumin, lysozyme and SARS-CoV-2 recombinant protein. We therefore present a facile route to produce nanoMIPs in large industrially relevant quantities (hundreds of mg) and at short timescales (within a day). Our method offers realistic opportunities for the industry to adopt such materials as an antibody replacement technology in diagnostics, biological extraction and therapeutics.
Collapse
Affiliation(s)
- Subrayal M Reddy
- Department of Chemistry, Institute of Materials and Investigative Sciences, UCLan Centre for Smart Materials, School of Pharmacy and Biomedical Sciences, University of Central Lancashire, Preston, PR1 2HE, UK.
| | - Andrei N Stephen
- Department of Chemistry, Institute of Materials and Investigative Sciences, UCLan Centre for Smart Materials, School of Pharmacy and Biomedical Sciences, University of Central Lancashire, Preston, PR1 2HE, UK.
| | - Mark A Holden
- Department of Chemistry, Institute of Materials and Investigative Sciences, UCLan Centre for Smart Materials, School of Pharmacy and Biomedical Sciences, University of Central Lancashire, Preston, PR1 2HE, UK.
| | - William J Stockburn
- Department of Chemistry, Institute of Materials and Investigative Sciences, UCLan Centre for Smart Materials, School of Pharmacy and Biomedical Sciences, University of Central Lancashire, Preston, PR1 2HE, UK.
| | - Sarah R Dennison
- Department of Chemistry, Institute of Materials and Investigative Sciences, UCLan Centre for Smart Materials, School of Pharmacy and Biomedical Sciences, University of Central Lancashire, Preston, PR1 2HE, UK.
| |
Collapse
|
5
|
Yaman D, Jimenez M, Ferreira Gonzalez S, Corrigan D. Current trends in electrochemical approaches for liver biomarker detection: a mini-review. Analyst 2024; 149:5156-5164. [PMID: 39351762 DOI: 10.1039/d4an01109k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2024]
Abstract
Aspartate aminotransferase (AST), alanine aminotransferase (ALT), bilirubin, gamma-glutamyl transferase (GGT), alkaline phosphatase (ALP), and albumin are well-established liver biomarkers with significant physiological functions. Alterations in these liver function tests can be indicative of the presence and progression of acute and chronic liver conditions such as liver cirrhosis, non-alcoholic fatty liver disease, biliary disease, and liver failure. Therefore, accurate and quantitative detection of these biomarkers is crucial for diagnosing and monitoring liver disease. There are several commercially available chemistry analyzers capable of simultaneously detecting all these biomarkers, as well as numerous biosensors designed for individual detection. Various techniques have been employed, including colorimetry, surface-enhanced Raman spectroscopy (SERS), electrochemiluminescence (ECL), fluorescence-based techniques, and electrochemical methods. Among these, electrochemical detection stands out due to its simplicity, cost-effectiveness, low sample volume requirement, label-free detection, high sensitivity, fast response times, miniaturization, and portability. Information on recently developed electrochemical biosensors is summarized through detailed tables and is intended to guide future research and development efforts in this area.
Collapse
Affiliation(s)
- Derya Yaman
- Centre for Advanced Measurement Research & Health Translation, Department of Pure and Applied Chemistry, University of Strathclyde, Glasgow, G1 1XL, UK.
| | - Melanie Jimenez
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, G4 0NW, UK
| | - Sofia Ferreira Gonzalez
- Centre for Inflammation Research, Institute for Regeneration and Repair, University of Edinburgh, Edinburgh, EH16 4UU, UK
| | - Damion Corrigan
- Centre for Advanced Measurement Research & Health Translation, Department of Pure and Applied Chemistry, University of Strathclyde, Glasgow, G1 1XL, UK.
| |
Collapse
|
6
|
Poimenova IA, Sozarukova MM, Ratova DMV, Nikitina VN, Khabibullin VR, Mikheev IV, Proskurnina EV, Proskurnin MA. Analytical Methods for Assessing Thiol Antioxidants in Biological Fluids: A Review. Molecules 2024; 29:4433. [PMID: 39339429 PMCID: PMC11433793 DOI: 10.3390/molecules29184433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2024] [Revised: 09/13/2024] [Accepted: 09/15/2024] [Indexed: 09/30/2024] Open
Abstract
Redox metabolism is an integral part of the glutathione system, encompassing reduced and oxidized glutathione, hydrogen peroxide, and associated enzymes. This core process orchestrates a network of thiol antioxidants like thioredoxins and peroxiredoxins, alongside critical thiol-containing proteins such as mercaptoalbumin. Modifications to thiol-containing proteins, including oxidation and glutathionylation, regulate cellular signaling influencing gene activities in inflammation and carcinogenesis. Analyzing thiol antioxidants, especially glutathione, in biological fluids offers insights into pathological conditions. This review discusses the analytical methods for biothiol determination, mainly in blood plasma. The study includes all key methodological aspects of spectroscopy, chromatography, electrochemistry, and mass spectrometry, highlighting their principles, benefits, limitations, and recent advancements that were not included in previously published reviews. Sample preparation and factors affecting thiol antioxidant measurements are discussed. The review reveals that the choice of analytical procedures should be based on the specific requirements of the research. Spectrophotometric methods are simple and cost-effective but may need more specificity. Chromatographic techniques have excellent separation capabilities but require longer analysis times. Electrochemical methods enable real-time monitoring but have disadvantages such as interference. Mass spectrometry-based approaches have high sensitivity and selectivity but require sophisticated instrumentation. Combining multiple techniques can provide comprehensive information on thiol antioxidant levels in biological fluids, enabling clearer insights into their roles in health and disease. This review covers the time span from 2010 to mid-2024, and the data were obtained from the SciFinder® (ACS), Google Scholar (Google), PubMed®, and ScienceDirect (Scopus) databases through a combination search approach using keywords.
Collapse
Affiliation(s)
- Iuliia A. Poimenova
- Analytical Chemistry Division, Department of Chemistry, Lomonosov Moscow State University, 1-3 Leninskie Gory, 119234 Moscow, Russia; (I.A.P.); (M.M.S.); (D.-M.V.R.); (V.N.N.); (V.R.K.)
| | - Madina M. Sozarukova
- Analytical Chemistry Division, Department of Chemistry, Lomonosov Moscow State University, 1-3 Leninskie Gory, 119234 Moscow, Russia; (I.A.P.); (M.M.S.); (D.-M.V.R.); (V.N.N.); (V.R.K.)
- Kurnakov Institute of General and Inorganic Chemistry, Russian Academy of Sciences, 117901 Moscow, Russia;
| | - Daria-Maria V. Ratova
- Analytical Chemistry Division, Department of Chemistry, Lomonosov Moscow State University, 1-3 Leninskie Gory, 119234 Moscow, Russia; (I.A.P.); (M.M.S.); (D.-M.V.R.); (V.N.N.); (V.R.K.)
| | - Vita N. Nikitina
- Analytical Chemistry Division, Department of Chemistry, Lomonosov Moscow State University, 1-3 Leninskie Gory, 119234 Moscow, Russia; (I.A.P.); (M.M.S.); (D.-M.V.R.); (V.N.N.); (V.R.K.)
| | - Vladislav R. Khabibullin
- Analytical Chemistry Division, Department of Chemistry, Lomonosov Moscow State University, 1-3 Leninskie Gory, 119234 Moscow, Russia; (I.A.P.); (M.M.S.); (D.-M.V.R.); (V.N.N.); (V.R.K.)
- Federal State Budgetary Institution of Science Institute of African Studies, Russian Academy of Sciences, Spiridonovka St., 30/1, 123001 Moscow, Russia
| | - Ivan V. Mikheev
- Analytical Chemistry Division, Department of Chemistry, Lomonosov Moscow State University, 1-3 Leninskie Gory, 119234 Moscow, Russia; (I.A.P.); (M.M.S.); (D.-M.V.R.); (V.N.N.); (V.R.K.)
| | - Elena V. Proskurnina
- Kurnakov Institute of General and Inorganic Chemistry, Russian Academy of Sciences, 117901 Moscow, Russia;
- Laboratory of Molecular Biology, Research Centre for Medical Genetics, 1 Moskvorechye St., 115522 Moscow, Russia
| | - Mikhail A. Proskurnin
- Analytical Chemistry Division, Department of Chemistry, Lomonosov Moscow State University, 1-3 Leninskie Gory, 119234 Moscow, Russia; (I.A.P.); (M.M.S.); (D.-M.V.R.); (V.N.N.); (V.R.K.)
| |
Collapse
|
7
|
Farag YG, Hanafi RS, Hammam MA. Novel dummy molecularly imprinted polymer for simultaneous solid-phase extraction of stanozolol metabolites from urine. Anal Bioanal Chem 2024; 416:3335-3347. [PMID: 38661944 PMCID: PMC11106188 DOI: 10.1007/s00216-024-05285-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 03/20/2024] [Accepted: 03/25/2024] [Indexed: 04/26/2024]
Abstract
Stanozolol, a synthetic derivative of testosterone, is one of the common doping drugs among athletes and bodybuilders. It is metabolized to a large extent and metabolites are detected in urine for a longer duration than the parent compound. In this study, a novel dummy molecularly imprinted polymer (DMIP) is developed as a sorbent for solid-phase extraction of stanozolol metabolites from spiked human urine samples. The optimized DMIP is composed of stanozolol as the dummy template, methacrylic acid as the functional monomer, and ethylene glycol dimethacrylate as the cross-linker in a ratio of 1:10:80. The extracted analytes were quantitively determined using a newly developed and validated ultrahigh-performance liquid chromatography tandem mass spectrometry method, where the limits of detection and quantitation were 0.91 and 1.81 ng mL-1, respectively, fulfilling the minimum required performance limit decided on by the World Anti-Doping Agency. The mean percentage extraction recoveries for 3'-hydroxystanozolol, 4β-hydroxystanozolol, and 16β-hydroxystanozolol are 97.80% ± 13.80, 83.16% ± 7.50, and 69.98% ± 2.02, respectively. As such, the developed DMISPE can serve as an efficient cost-effective tool for doping and regulatory agencies for simultaneous clean-up of the stanozolol metabolites prior to their quantification.
Collapse
Affiliation(s)
- Yomna G Farag
- Pharmaceutical Chemistry Department, Faculty of Pharmacy and Biotechnology, German University in Cairo, Cairo, 11835, Egypt
| | - Rasha S Hanafi
- Pharmaceutical Chemistry Department, Faculty of Pharmacy and Biotechnology, German University in Cairo, Cairo, 11835, Egypt.
| | - Mennatallah A Hammam
- Pharmaceutical Chemistry Department, Faculty of Pharmacy and Biotechnology, German University in Cairo, Cairo, 11835, Egypt
- Department of Chemistry, School of Life and Medical Sciences, University of Hertfordshire Hosted By Global Academic Foundation, New Administrative Capital, Cairo, 4813001, Egypt
| |
Collapse
|
8
|
Jahanban-Esfahlan A, Amarowicz R. Molecularly imprinted polymers for sensing/depleting human serum albumin (HSA): A critical review of recent advances and current challenges. Int J Biol Macromol 2024; 266:131132. [PMID: 38531529 DOI: 10.1016/j.ijbiomac.2024.131132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2024] [Revised: 03/22/2024] [Accepted: 03/22/2024] [Indexed: 03/28/2024]
Abstract
Human serum albumin (HSA) is an essential biomacromolecule in the blood circulatory system because it carries numerous molecules, including fatty acids (FAs), bilirubin, metal ions, hormones, and different pharmaceuticals, and plays a significant role in regulating blood osmotic pressure. Fluctuations in HSA levels in human biofluids, particularly urine and serum, are associated with several disorders, such as elevated blood pressure, diabetes mellitus (DM), liver dysfunction, and a wide range of renal diseases. Thus, the ability to quickly and accurately measure HSA levels is important for the rapid identification of these disorders in human populations. Molecularly imprinted polymers (MIPs), well known as artificial antibodies (Abs), have been extensively used for the quantitative detection of small molecules and macromolecules, especially HSA, in recent decades. This review highlights major challenges and recent developments in the application of MIPs to detect HSA in artificial and real samples. The fabrication and application of various MIPs for the depletion of HSA are also discussed, as well as different MIP preparation approaches and strategies for overcoming obstacles that hinder the development of MIPs with high efficiency and recognition capability for HSA determination/depletion.
Collapse
Affiliation(s)
- Ali Jahanban-Esfahlan
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz 5165665813, Iran.
| | - Ryszard Amarowicz
- Division of Food Sciences, Institute of Animal Reproduction and Food Research of the Polish Academy of Sciences, Street Tuwima 10, 10-748 Olsztyn, Poland.
| |
Collapse
|
9
|
Zhang X, Yarman A, Kovács N, Bognár Z, Gyurcsányi RE, Bier FF, Scheller FW. Specific features of epitope-MIPs and whole-protein MIPs as illustrated for AFP and RBD of SARS-CoV-2. Mikrochim Acta 2024; 191:242. [PMID: 38573524 DOI: 10.1007/s00604-024-06325-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Accepted: 03/22/2024] [Indexed: 04/05/2024]
Abstract
Molecularly imprinted polymer (MIP) nanofilms for alpha-fetoprotein (AFP) and the receptor binding domain (RBD) of the spike protein of SARS-CoV-2 using either a peptide (epitope-MIP) or the whole protein (protein-MIP) as the template were prepared by electropolymerization of scopoletin. Conducting atomic force microscopy revealed after template removal and electrochemical deposition of gold a larger surface density of imprinted cavities for the epitope-imprinted polymers than when using the whole protein as template. However, comparable affinities towards the respective target protein (AFP and RBD) were obtained for both types of MIPs as expressed by the KD values in the lower nanomolar range. On the other hand, while the cross reactivity of both protein-MIPs towards human serum albumin (HSA) amounts to around 50% in the saturation region, the nonspecific binding to the respective epitope-MIPs is as low as that for the non-imprinted polymer (NIP). This effect might be caused by the different sizes of the imprinted cavities. Thus, in addition to the lower costs the reduced nonspecific binding is an advantage of epitope-imprinted polymers for the recognition of proteins.
Collapse
Affiliation(s)
- Xiaorong Zhang
- Institute of Biochemistry and Biology, University of Potsdam, Karl-Liebknecht Str. 24-25, 14476, Potsdam, Germany.
| | - Aysu Yarman
- Molecular Biotechnology, Faculty of Science, Turkish-German University, Sahinkaya Cad. Beykoz, Istanbul, 34820, Turkey
| | - Norbert Kovács
- BME "Lendület" Chemical Nanosensors Research Group, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, Műegyetem rkp. 3, 1111, Budapest, Hungary
| | - Zsófia Bognár
- BME "Lendület" Chemical Nanosensors Research Group, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, Műegyetem rkp. 3, 1111, Budapest, Hungary
| | - Róbert E Gyurcsányi
- BME "Lendület" Chemical Nanosensors Research Group, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, Műegyetem rkp. 3, 1111, Budapest, Hungary
- HUN-REN-BME Computation Driven Chemistry Research Group, Műegyetem rkp. 3, 1111, Budapest, Hungary
| | - Frank F Bier
- Institute of Biochemistry and Biology, University of Potsdam, Karl-Liebknecht Str. 24-25, 14476, Potsdam, Germany
| | - Frieder W Scheller
- Institute of Biochemistry and Biology, University of Potsdam, Karl-Liebknecht Str. 24-25, 14476, Potsdam, Germany
| |
Collapse
|
10
|
Wang Y, Huo F, Yin C. Development of Human Serum Albumin Fluorescent Probes in Detection, Imaging, and Disease Therapy. J Phys Chem B 2024; 128:1121-1138. [PMID: 38266243 DOI: 10.1021/acs.jpcb.3c06915] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2024]
Abstract
Human serum albumin (HSA) acts as a repository and transporter of substances in the blood. An abnormal concentration may indicate the occurrence of liver- and kidney-related diseases, which has attracted people to investigate the precise quantification of HSA in body fluids. Fluorescent probes can combine with HSA covalently or noncovalently to quantify HSA in urine and plasma. Moreover, probes combined with HSA can improve its photophysical properties; probe-HSA has been applied in real-time monitoring and photothermal and photodynamic therapy in vivo. This Review will introduce fluorescent probes for quantitative HSA according to the three reaction mechanisms of spatial structure, enzymatic reaction, and self-assembly and systematically introduce the application of probes combined with HSA in disease imaging and phototherapy. It will help develop multifunctional applications for HSA probes and provide assistance in the early diagnosis and treatment of diseases.
Collapse
Affiliation(s)
- Yuting Wang
- Key Laboratory of Chemical Biology and Molecular Engineering of Ministry of Education, Key Laboratory of Materials for Energy Conversion and Storage of Shanxi Province, Institute of Molecular Science, Shanxi University, Taiyuan 030006, China
| | - Fangjun Huo
- Research Institute of Applied Chemistry, Shanxi University, Taiyuan 030006, China
| | - Caixia Yin
- Key Laboratory of Chemical Biology and Molecular Engineering of Ministry of Education, Key Laboratory of Materials for Energy Conversion and Storage of Shanxi Province, Institute of Molecular Science, Shanxi University, Taiyuan 030006, China
| |
Collapse
|
11
|
Zhang X, Yarman A, Bagheri M, El-Sherbiny IM, Hassan RYA, Kurbanoglu S, Waffo AFT, Zebger I, Karabulut TC, Bier FF, Lieberzeit P, Scheller FW. Imprinted Polymers on the Route to Plastibodies for Biomacromolecules (MIPs), Viruses (VIPs), and Cells (CIPs). ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2024; 187:107-148. [PMID: 37884758 DOI: 10.1007/10_2023_234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2023]
Abstract
Around 30% of the scientific papers published on imprinted polymers describe the recognition of proteins, nucleic acids, viruses, and cells. The straightforward synthesis from only one up to six functional monomers and the simple integration into a sensor are significant advantages as compared with enzymes or antibodies. Furthermore, they can be synthesized against toxic substances and structures of low immunogenicity and allow multi-analyte measurements via multi-template synthesis. The affinity is sufficiently high for protein biomarkers, DNA, viruses, and cells. However, the cross-reactivity of highly abundant proteins is still a challenge.
Collapse
Affiliation(s)
- Xiaorong Zhang
- Institute for Biochemistry and Biology, Universität Potsdam, Potsdam, Germany
| | - Aysu Yarman
- Molecular Biotechnology, Faculty of Science, Turkish-German University, Istanbul, Turkey
| | - Mahdien Bagheri
- Department of Physical Chemistry, Faculty for Chemistry, University of Vienna, Vienna, Austria
| | - Ibrahim M El-Sherbiny
- Nanoscience Program, University of Science and Technology (UST), Zewail City of Science and Technology, Giza, Egypt
- Center for Materials Science (CMS), Zewail City of Science and Technology, Giza, Egypt
| | - Rabeay Y A Hassan
- Nanoscience Program, University of Science and Technology (UST), Zewail City of Science and Technology, Giza, Egypt
- Center for Materials Science (CMS), Zewail City of Science and Technology, Giza, Egypt
| | - Sevinc Kurbanoglu
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | | | - Ingo Zebger
- Institut für Chemie, PC 14 Technische Universität Berlin, Berlin, Germany
| | | | - Frank F Bier
- Institute for Biochemistry and Biology, Universität Potsdam, Potsdam, Germany
| | - Peter Lieberzeit
- Department of Physical Chemistry, Faculty for Chemistry, University of Vienna, Vienna, Austria.
| | - Frieder W Scheller
- Institute for Biochemistry and Biology, Universität Potsdam, Potsdam, Germany.
| |
Collapse
|
12
|
Behnam MAM, Basché T, Klein CDP. 2,2'-Bithiophene as sensor tag for ligand-protein binding assays based on Förster resonance energy transfer. Anal Biochem 2023; 682:115335. [PMID: 37777080 DOI: 10.1016/j.ab.2023.115335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 08/15/2023] [Accepted: 09/27/2023] [Indexed: 10/02/2023]
Abstract
Ligand-protein binding assays based on intrinsic protein fluorescence are straightforward, inexpensive methods to study ligand-protein interactions. However, their applicability is limited to ligands that can interfere with protein emission. In this Note, we describe the applicability of 2,2'-bithiophene as a FRET-based sensor tag, that can be incorporated into high-affinity ligands to generate target-specific compounds able to quench protein fluorescence upon binding. The generated ligands were assessed in different assay designs. Considerations to account for possible sources of interference with the assay readout are addressed, besides interpretation of the obtained results.
Collapse
Affiliation(s)
- Mira A M Behnam
- Medicinal Chemistry, Institute of Pharmacy and Molecular Biotechnology IPMB, Heidelberg University, Im Neuenheimer Feld 364, 69120, Heidelberg, Germany
| | - Thomas Basché
- Department of Chemistry, Johannes Gutenberg-University, Mainz, Germany
| | - Christian D P Klein
- Medicinal Chemistry, Institute of Pharmacy and Molecular Biotechnology IPMB, Heidelberg University, Im Neuenheimer Feld 364, 69120, Heidelberg, Germany.
| |
Collapse
|
13
|
Stephen AN, Dennison SR, Holden MA, Reddy SM. Rapid sub-nanomolar protein determination in serum using electropolymerized molecularly imprinted polymers (E-MIPs). Analyst 2023; 148:5476-5485. [PMID: 37767770 DOI: 10.1039/d3an01498c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/29/2023]
Abstract
Rapid detection of biologicals is important for a range of applications such as medical screening and diagnostics. Antibodies are typically employed for biosensing with high sensitivity and selectivity but can take months to prepare. Here, we investigate electropolymerized molecularly imprinted polymers (E-MIPs), which are produced in minutes as alternative-antibody rapid biosensors for the selective recognition of model proteins bovine haemoglobin (BHb) and bovine serum albumin (BSA). We evaluated two disposable screen-printed electrodes (SPE) designated AT-Au and BT-Au based on their different annealing temperatures. E-MIPs for BHb demonstrated an imprinting factor of 146 : 1 at 1 nM and 12 : 1 at 0.1 nM, showing high effectiveness of E-MIPs compared to their control non-imprinted polymers. The BHb imprinted E-MIP, when tested against BSA as a non-target protein, gave a selectivity factor of 6 : 1 for BHb. Sensor sensitivity directly depended on the nature of the SPE, with AT-Au SPE demonstrating limits of detection in the sub-micromolar range typically achieved for MIPs, while BT-Au SPE exhibited sensitivity in the sub-nanomolar range for target protein. We attribute this to differences in electrode surface area between AT-Au and BT-Au SPEs. The E-MIPs were also tested in calf serum as a model biological medium. The BT-Au SPE MIPs detected the presence of target protein in <10 min with an LOD of 50 pM and LOQ of 100 pM, suggesting their suitability for protein determination in serum with minimal sample preparation. Using electrochemical impedance spectroscopy, we determine equilibrium dissociation constants (KD) for E-MIPs using the Hill-Langmuir adsorption model. KD of BHb E-MIP was determined to be 0.86 ± 0.11 nM.
Collapse
Affiliation(s)
- A N Stephen
- Department of Chemistry, UCLan Centre for Smart Materials, School of Pharmacy and Biomedical Sciences, University of Central Lancashire, Preston, PR1 2HE, UK.
| | - S R Dennison
- School of Pharmacy and Biomedical Sciences, University of Central Lancashire, Preston, PR1 2HE, UK
| | - M A Holden
- Department of Chemistry, UCLan Centre for Smart Materials, School of Pharmacy and Biomedical Sciences, University of Central Lancashire, Preston, PR1 2HE, UK.
| | - S M Reddy
- Department of Chemistry, UCLan Centre for Smart Materials, School of Pharmacy and Biomedical Sciences, University of Central Lancashire, Preston, PR1 2HE, UK.
| |
Collapse
|
14
|
Zhu R, Figueroa-Miranda G, Zhou L, Hu Z, Lenyk B, Ingebrandt S, Offenhäusser A, Mayer D. A Combined Plasmonic and Electrochemical Aptasensor Based on Gold Nanopit Arrays for the Detection of Human Serum Albumin. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:2374. [PMID: 37630959 PMCID: PMC10458775 DOI: 10.3390/nano13162374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Revised: 08/04/2023] [Accepted: 08/17/2023] [Indexed: 08/27/2023]
Abstract
Electrochemical and optical platforms are commonly employed in designing biosensors. However, one signal readout can easily lead to inaccuracies due to the effect of nonstandard test procedures, different operators, and experimental environments. We have developed a dual-signal protocol that combined two transducer principles in one aptamer-based biosensor by simultaneously performing electrochemical- and extraordinary optical transmission (EOT)-based plasmonic detection using gold nanopit arrays (AuNpA). Compared with full hole structures, we found that nanopits, that did not fully penetrate the gold film, not only exhibited a better plasmonic bandwidth and refractive index sensitivity both in the finite-difference time-domain simulation and in experiments by shielding the gold/quartz mode but also enlarged the electrochemical active surface area. Therefore, the periodic non-fully penetrating AuNpA were modified with ferrocene-labeled human serum albumin aptamer receptors. The formation of the receptor layer and human serum albumin binding complex induced a conformational change, which resulted in variation in the electron transfer between the electro-active ferrocene units and the AuNpA surface. Simultaneously, the binding event caused a surface plasmon polaritons wavelength shift corresponding to a change in the surface refractive index. Interestingly, although both transducers recorded the same binding process, they led to different limits of detection, dynamic ranges, and sensitivities. The electrochemical transducer showed a dynamic detection range from 1 nM to 600 μM, while the optical transducer covered high concentrations from 100 μM to 600 μM. This study not only provides new insights into the design of plasmonic nanostructures but also potentially opens an exciting avenue for dual-signal disease diagnosis and point-of-care testing applications.
Collapse
Affiliation(s)
- Ruifeng Zhu
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
- Institute of Materials in Electrical Engineering 1, RWTH Aachen University, 52074 Aachen, Germany
| | - Gabriela Figueroa-Miranda
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
| | - Lei Zhou
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
| | - Ziheng Hu
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
| | - Bohdan Lenyk
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
- Department of Physics, University of Konstanz, 78457 Konstanz, Germany
| | - Sven Ingebrandt
- Institute of Materials in Electrical Engineering 1, RWTH Aachen University, 52074 Aachen, Germany
| | - Andreas Offenhäusser
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
| | - Dirk Mayer
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
| |
Collapse
|
15
|
Zulfiqar A, Zafar F, Yaqub B, Mahmoud HMA, Shah M, Widaa EMA, Nawaz H, Akhtar N, Nishan U. Cobalt oxide modified sulfur and phosphorus Co-doped g-C 3N 4 for screening of urinary human albumin. Mikrochim Acta 2023; 190:355. [PMID: 37594627 DOI: 10.1007/s00604-023-05936-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 07/27/2023] [Indexed: 08/19/2023]
Abstract
The fabrication of a heteroatom-doped nanocomposite based on cobalt oxide modified sulfur, phosphorus co-doped carbon nitride (Co3O4/SP-CN) with increased active sites is reported. The synthesized nanocomposite offers surprisingly high electrocatalytic oxidation efficacy toward human albumin (HA) despite its agglomeration. This improved efficacy of Co3O4/SP-CN nanocomposite could be attributed to its increased adsorption sites and surface defects, fast charge transportation capability, and conductivity. Additionally, morphological and compositional analysis of the fabricated Co3O4/SP-CN material has been performed through scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray photon spectroscopy (XPS), and Raman spectroscopy. The fabricated electrode shows remarkable amperometric response against the HA with a limit of detection of 8.39 nM and linear range of 20-4000 nM at applied potential of 0.25 V versus Ag/AgCl in 0.1 M PBS (pH 8.2). The designed Co3O4/SP-CN electrode has been successfully applied to monitor HA in urine samples of diabetic patient with recovery percentage from 94.1 and 92.1% and with relative standard deviation (RSD) values of 5.8 and 7.8%. According to the best of our knowledge, this is the first report to use a Co3O4/SP-CN-based graphitic pencil (GP) electrode for monitoring of HA for early diagnosis of diabetic nephropathy.
Collapse
Affiliation(s)
- Anam Zulfiqar
- Department of Biochemistry, Bahauddin Zakariya University (BZU), Multan, 60800, Pakistan
| | - Farhan Zafar
- Department of Chemistry, COMSATS University Islamabad, Lahore Campus, Lahore, 54000, Pakistan
| | - Bushra Yaqub
- Department of Biochemistry, Bahauddin Zakariya University (BZU), Multan, 60800, Pakistan
| | - HassabAlla M A Mahmoud
- Department of Physics, Faculty of Sciences and Arts, King Khalid University, Muhayil Asir, 63311, Saudi Arabia
| | - Mohibullah Shah
- Department of Biochemistry, Bahauddin Zakariya University (BZU), Multan, 60800, Pakistan.
| | - Einas M A Widaa
- Department of Physics, Turabah University College, Taif University, Box 11099, Taif, PO, 21944, Saudi Arabia
| | - Haq Nawaz
- Department of Biochemistry, Bahauddin Zakariya University (BZU), Multan, 60800, Pakistan
| | - Naeem Akhtar
- Institute of Chemical Sciences, Bahauddin Zakariya University (BZU), Multan, 60800, Pakistan.
| | - Umar Nishan
- Department of Chemistry, Kohat University of Science & Technology, Kohat, Pakistan
| |
Collapse
|
16
|
Indah Wardani N, Kanatharana P, Thavarungkul P, Limbut W. Molecularly imprinted polymer dual electrochemical sensor for the one-step determination of albuminuria to creatinine ratio (ACR). Talanta 2023; 265:124769. [PMID: 37329752 DOI: 10.1016/j.talanta.2023.124769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 06/02/2023] [Accepted: 06/04/2023] [Indexed: 06/19/2023]
Abstract
The urinary albumin to creatinine ratio (ACR) is a convenient and accurate biomarker of chronic kidney disease (CKD). An electrochemical sensor for the quantification of ACR was developed based on a dual screen-printed carbon electrode (SPdCE). The SPdCE was modified with carboxylated multiwalled carbon nanotubes (f-MWCNTs) and redox probes of polymethylene blue (PMB) for creatinine and ferrocene (Fc) for albumin. The modified working electrodes were then molecularly imprinted with coated with polymerized poly-o-phenylenediamine (PoPD) to form surfaces that could be separately imprinted with creatinine and albumin template molecules. The seeded polymer layers were polymerized with a second coating of PoPD and the templates were removed to form two different molecularly imprinted polymer (MIP) layers. The dual sensor presented recognition sites for creatinine and albumin on different working electrodes, enabling the measurement of each analyte in one potential scan of square wave voltammetry (SWV). The proposed sensor produced linear ranges of 5.0-100 ng mL-1 and 100-2500 ng mL-1 for creatinine, and 5.0-100 ng mL-1 for albumin. LODs were 1.5 ± 0.2 ng mL-1 and 1.5 ± 0.3 ng mL-1, respectively. The dual MIP sensor was highly selective and stable for seven weeks at room temperature. The ACRs obtained using the proposed sensor compared well (P > 0.05) with the results from immunoturbidimetric and enzymatic methods.
Collapse
Affiliation(s)
- Nur Indah Wardani
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Proespichaya Kanatharana
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Panote Thavarungkul
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Warakorn Limbut
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.
| |
Collapse
|
17
|
Pilvenyte G, Ratautaite V, Boguzaite R, Ramanavicius S, Chen CF, Viter R, Ramanavicius A. Molecularly Imprinted Polymer-Based Electrochemical Sensors for the Diagnosis of Infectious Diseases. BIOSENSORS 2023; 13:620. [PMID: 37366985 DOI: 10.3390/bios13060620] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 05/28/2023] [Accepted: 05/31/2023] [Indexed: 06/28/2023]
Abstract
The appearance of biological molecules, so-called biomarkers in body fluids at abnormal concentrations, is considered a good tool for detecting disease. Biomarkers are usually looked for in the most common body fluids, such as blood, nasopharyngeal fluids, urine, tears, sweat, etc. Even with significant advances in diagnostic technology, many patients with suspected infections receive empiric antimicrobial therapy rather than appropriate treatment, which is driven by rapid identification of the infectious agent, leading to increased antimicrobial resistance. To positively impact healthcare, new tests are needed that are pathogen-specific, easy to use, and produce results quickly. Molecularly imprinted polymer (MIP)-based biosensors can achieve these general goals and have enormous potential for disease detection. This article aimed to overview recent articles dedicated to electrochemical sensors modified with MIP to detect protein-based biomarkers of certain infectious diseases in human beings, particularly the biomarkers of infectious diseases, such as HIV-1, COVID-19, Dengue virus, and others. Some biomarkers, such as C-reactive protein (CRP) found in blood tests, are not specific for a particular disease but are used to identify any inflammation process in the body and are also under consideration in this review. Other biomarkers are specific to a particular disease, e.g., SARS-CoV-2-S spike glycoprotein. This article analyzes the development of electrochemical sensors using molecular imprinting technology and the used materials' influence. The research methods, the application of different electrodes, the influence of the polymers, and the established detection limits are reviewed and compared.
Collapse
Affiliation(s)
- Greta Pilvenyte
- Department of Nanotechnology, State Research Institute Center for Physical Sciences and Technology (FTMC), Saulėtekio Av. 3, LT-10257 Vilnius, Lithuania
- Department of Physical Chemistry, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University (VU), Naugarduko Str. 24, LT-03225 Vilnius, Lithuania
| | - Vilma Ratautaite
- Department of Nanotechnology, State Research Institute Center for Physical Sciences and Technology (FTMC), Saulėtekio Av. 3, LT-10257 Vilnius, Lithuania
- Department of Physical Chemistry, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University (VU), Naugarduko Str. 24, LT-03225 Vilnius, Lithuania
| | - Raimonda Boguzaite
- Department of Nanotechnology, State Research Institute Center for Physical Sciences and Technology (FTMC), Saulėtekio Av. 3, LT-10257 Vilnius, Lithuania
- Department of Physical Chemistry, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University (VU), Naugarduko Str. 24, LT-03225 Vilnius, Lithuania
| | - Simonas Ramanavicius
- Department of Electrochemical Material Science, State Research Institute Center for Physical Sciences and Technology (FTMC), Saulėtekio Av. 3, LT-10257 Vilnius, Lithuania
| | - Chien-Fu Chen
- Institute of Applied Mechanics, National Taiwan University, Taipei City 106, Taiwan
| | - Roman Viter
- Institute of Atomic Physics and Spectroscopy, University of Latvia, 19 Raina Blvd., LV-1586 Riga, Latvia
- Center for Collective Use of Scientific Equipment, Sumy State University, 31, Sanatornaya st., 40018 Sumy, Ukraine
| | - Arunas Ramanavicius
- Department of Nanotechnology, State Research Institute Center for Physical Sciences and Technology (FTMC), Saulėtekio Av. 3, LT-10257 Vilnius, Lithuania
- Department of Physical Chemistry, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University (VU), Naugarduko Str. 24, LT-03225 Vilnius, Lithuania
| |
Collapse
|
18
|
Xiao W, Li Y, Xiong Y, Chen Z, Li H. Fluorescence turn-on detection of human serum albumin based on the assembly of gold nanoclusters and bromocresol green. Anal Bioanal Chem 2023:10.1007/s00216-023-04717-4. [PMID: 37154935 DOI: 10.1007/s00216-023-04717-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Revised: 04/22/2023] [Accepted: 04/25/2023] [Indexed: 05/10/2023]
Abstract
As the most abundant protein in plasma, human serum albumin plays a vital role in physiological processes, such as maintaining blood osmotic pressure and carrying small-molecule ligands. Since the content of albumin in the human serum can reflect the status of liver and renal function, albumin quantitation is significant in clinical diagnosis. In this work, fluorescence turn-on detection of human serum albumin (HSA) had been performed based on the assembly of gold nanoclusters and bromocresol green. Gold nanoclusters (AuNCs) capped by reduced glutathione (GSH) were assembled with bromocresol green (BCG), and the assembly was used as a fluorescent probe for HSA. After BCG assembling, the fluorescence of gold nanoclusters was nearly quenched. In acidic solution, HSA can selectively bind to BCG on the assembly and recover the fluorescence of the solution. Based on this turn-on fluorescence, ratiometric HSA quantification was realized. Under optimal conditions, HSA detection by the probe possessed a good linear relationship in the range of 0.40-22.50 mg·mL-1, and the detection limit was 0.27 ± 0.04 mg·mL-1 (3σ, n = 3). Common coexisting components in serum and blood proteins did not interfere with the detection of HSA. This method has the advantages of easy manipulation and high sensitivity, and the fluorescent response is insensitive to reaction time.
Collapse
Affiliation(s)
- Wenxiang Xiao
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, 541004, China.
- Guangxi Colleges and Universities Key Laboratory of Biomedical Sensing and Intelligent Instrument, Guilin University of Electronic Technology, Guilin, 541004, China.
| | - Yaoxin Li
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, 541004, China
| | - Yinan Xiong
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, 541004, China
| | - ZhenCheng Chen
- Guangxi Colleges and Universities Key Laboratory of Biomedical Sensing and Intelligent Instrument, Guilin University of Electronic Technology, Guilin, 541004, China
| | - Hua Li
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, 541004, China.
- Guangxi Colleges and Universities Key Laboratory of Biomedical Sensing and Intelligent Instrument, Guilin University of Electronic Technology, Guilin, 541004, China.
| |
Collapse
|
19
|
Zhang K, Wang Y, Zhang Y. Fabrication of molecular imprinting electrochemical sensor for determination of 2-O-(β-d-glucopyranosyl) ascorbic acid. INT J ELECTROCHEM SC 2023. [DOI: 10.1016/j.ijoes.2023.01.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
|
20
|
Akgönüllü S, Kılıç S, Esen C, Denizli A. Molecularly Imprinted Polymer-Based Sensors for Protein Detection. Polymers (Basel) 2023; 15:629. [PMID: 36771930 PMCID: PMC9919373 DOI: 10.3390/polym15030629] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 01/23/2023] [Accepted: 01/23/2023] [Indexed: 01/28/2023] Open
Abstract
The accurate detection of biological substances such as proteins has always been a hot topic in scientific research. Biomimetic sensors seek to imitate sensitive and selective mechanisms of biological systems and integrate these traits into applicable sensing platforms. Molecular imprinting technology has been extensively practiced in many domains, where it can produce various molecular recognition materials with specific recognition capabilities. Molecularly imprinted polymers (MIPs), dubbed plastic antibodies, are artificial receptors with high-affinity binding sites for a particular molecule or compound. MIPs for protein recognition are expected to have high affinity via numerous interactions between polymer matrices and multiple functional groups of the target protein. This critical review briefly describes recent advances in the synthesis, characterization, and application of MIP-based sensor platforms used to detect proteins.
Collapse
Affiliation(s)
- Semra Akgönüllü
- Department of Chemistry, Faculty of Science, Hacettepe University, 06800 Ankara, Turkey
| | - Seçkin Kılıç
- Department of Chemistry, Faculty of Science, Hacettepe University, 06800 Ankara, Turkey
| | - Cem Esen
- Department of Chemistry, Faculty of Science, Aydın Adnan Menderes University, 09010 Aydın, Turkey
| | - Adil Denizli
- Department of Chemistry, Faculty of Science, Hacettepe University, 06800 Ankara, Turkey
| |
Collapse
|
21
|
Exploring Molecular Interaction of Cefpirome with Human Serum Albumin: in vitro and in silico Approaches. J Mol Struct 2022. [DOI: 10.1016/j.molstruc.2022.134723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/05/2022]
|
22
|
Yahya I, Hassan MA, Maidin NNM, Mohamed MA. SWCNT Network-FET Device for Human Serum Albumin Detection. SENSORS (BASEL, SWITZERLAND) 2022; 22:8212. [PMID: 36365910 PMCID: PMC9653970 DOI: 10.3390/s22218212] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 10/18/2022] [Accepted: 10/18/2022] [Indexed: 06/16/2023]
Abstract
A thin film of single-walled carbon nanotube (SWCNT) network field-effect transistor (FET) was fabricated by a simple, fast, and reliable deposition method for electronic applications. This study aims to develop a method for fabricating a thin film of random SWCNTs to be used as a transducer to detect human serum albumin (HSA) in biosensor applications. The random SWCNT network was deposited using the airbrush technique. The morphology of the CNT network was examined by utilising atomic force microscopy (AFM) and field-emission scanning electron microscopy (FESEM), while electrical characteristics were analysed using three-terminal IV measurements. The thin film (SWCNT network) was applied as a transducer to detect human serum albumin (HSA) based on its covalent interaction with antibodies. HSA plays a significant part in the physiological functions of the human body. The surface alteration of the SWCNTs was verified using Fourier transform infrared (FTIR) spectroscopy. Electrical current-voltage measurements validated the surface binding and HSA detection. The biosensor linearly recorded a 0.47 fg/mL limit of detection (LOD) and a high sensitivity of 3.44 μA (g/mL)-1 between 1 fg/mL and 10 pg/mL. This device can also be used to identify a genuine HSA despite interference from other biomolecules (i.e., bovine serum albumin (BSA)), thus demonstrating the random SWCNT-FET immunosensor ability to quantify HSA in a complex biological environment.
Collapse
Affiliation(s)
- Iskandar Yahya
- Faculty of Engineering & Built Environment, National University of Malaysia (UKM), Bangi 43600, Malaysia
| | - Muhamad Azuddin Hassan
- Institute of Microengineering and Nanoelectronics (IMEN), National University of Malaysia (UKM), Bangi 43600, Malaysia
| | - Nur Nasyifa Mohd Maidin
- Institute of Microengineering and Nanoelectronics (IMEN), National University of Malaysia (UKM), Bangi 43600, Malaysia
| | - Mohd Ambri Mohamed
- Institute of Microengineering and Nanoelectronics (IMEN), National University of Malaysia (UKM), Bangi 43600, Malaysia
| |
Collapse
|
23
|
Mazzotta E, Di Giulio T, Malitesta C. Electrochemical sensing of macromolecules based on molecularly imprinted polymers: challenges, successful strategies, and opportunities. Anal Bioanal Chem 2022; 414:5165-5200. [PMID: 35277740 PMCID: PMC8916950 DOI: 10.1007/s00216-022-03981-0] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 02/08/2022] [Accepted: 02/15/2022] [Indexed: 12/21/2022]
Abstract
Looking at the literature focused on molecularly imprinted polymers (MIPs) for protein, it soon becomes apparent that a remarkable increase in scientific interest and exploration of new applications has been recorded in the last several years, from 42 documents in 2011 to 128 just 10 years later, in 2021 (Scopus, December 2021). Such a rapid threefold increase in the number of works in this field is evidence that the imprinting of macromolecules no longer represents a distant dream of optimistic imprinters, as it was perceived until only a few years ago, but is rapidly becoming an ever more promising and reliable technology, due to the significant achievements in the field. The present critical review aims to summarize some of them, evidencing the aspects that have contributed to the success of the most widely used strategies in the field. At the same time, limitations and drawbacks of less frequently used approaches are critically discussed. Particular focus is given to the use of a MIP for protein in the assembly of electrochemical sensors. Sensor design indeed represents one of the most active application fields of imprinting technology, with electrochemical MIP sensors providing the broadest spectrum of protein analytes among the different sensor configurations.
Collapse
Affiliation(s)
- Elisabetta Mazzotta
- Laboratory of Analytical Chemistry, Department of Biological and Environmental Sciences and Technologies (Di.S.Te.B.A.), University of Salento, via Monteroni, 73100, Lecce, Italy.
| | - Tiziano Di Giulio
- Laboratory of Analytical Chemistry, Department of Biological and Environmental Sciences and Technologies (Di.S.Te.B.A.), University of Salento, via Monteroni, 73100, Lecce, Italy
| | - Cosimino Malitesta
- Laboratory of Analytical Chemistry, Department of Biological and Environmental Sciences and Technologies (Di.S.Te.B.A.), University of Salento, via Monteroni, 73100, Lecce, Italy
| |
Collapse
|
24
|
Gökoğlu E, Kıpçak F, Taskin-Tok T, Duyar H, Seferoğlu Z. Structural analysis and calf thymus DNA/HSA binding properties of new carbazole derivative containing piperazine. J Photochem Photobiol A Chem 2022. [DOI: 10.1016/j.jphotochem.2021.113720] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
25
|
Lin SY, Lin CY. Electrochemically-functionalized CNT/ABTS nanozyme enabling sensitive and selective voltammetric detection of microalbuminuria. Anal Chim Acta 2022; 1197:339517. [PMID: 35168734 DOI: 10.1016/j.aca.2022.339517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Revised: 01/11/2022] [Accepted: 01/17/2022] [Indexed: 11/01/2022]
|
26
|
Bognár Z, Supala E, Yarman A, Zhang X, Bier FF, Scheller FW, Gyurcsányi RE. Peptide epitope-imprinted polymer microarrays for selective protein recognition. Application for SARS-CoV-2 RBD protein. Chem Sci 2022; 13:1263-1269. [PMID: 35222909 PMCID: PMC8809392 DOI: 10.1039/d1sc04502d] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Accepted: 11/23/2021] [Indexed: 12/18/2022] Open
Abstract
We introduce a practically generic approach for the generation of epitope-imprinted polymer-based microarrays for protein recognition on surface plasmon resonance imaging (SPRi) chips. The SPRi platform allows the subsequent rapid screening of target binding kinetics in a multiplexed and label-free manner. The versatility of such microarrays, both as synthetic and screening platform, is demonstrated through developing highly affine molecularly imprinted polymers (MIPs) for the recognition of the receptor binding domain (RBD) of SARS-CoV-2 spike protein. A characteristic nonapeptide GFNCYFPLQ from the RBD and other control peptides were microspotted onto gold SPRi chips followed by the electrosynthesis of a polyscopoletin nanofilm to generate in one step MIP arrays. A single chip screening of essential synthesis parameters, including the surface density of the template peptide and its sequence led to MIPs with dissociation constants (K D) in the lower nanomolar range for RBD, which exceeds the affinity of RBD for its natural target, angiotensin-convertase 2 enzyme. Remarkably, the same MIPs bound SARS-CoV-2 virus like particles with even higher affinity along with excellent discrimination of influenza A (H3N2) virus. While MIPs prepared with a truncated heptapeptide template GFNCYFP showed only a slightly decreased affinity for RBD, a single mismatch in the amino acid sequence of the template, i.e. the substitution of the central cysteine with a serine, fully suppressed the RBD binding.
Collapse
Affiliation(s)
- Zsófia Bognár
- BME "Lendület" Chemical Nanosensors Research Group, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics Szt. Gellért tér 4 1111 Budapest Hungary
| | - Eszter Supala
- BME "Lendület" Chemical Nanosensors Research Group, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics Szt. Gellért tér 4 1111 Budapest Hungary
| | - Aysu Yarman
- Institute of Biochemistry and Biology, University of Potsdam Karl-Liebknecht-Str. 24-25 14476 Potsdam OT Golm Germany
| | - Xiaorong Zhang
- Institute of Biochemistry and Biology, University of Potsdam Karl-Liebknecht-Str. 24-25 14476 Potsdam OT Golm Germany
| | - Frank F Bier
- Institute of Biochemistry and Biology, University of Potsdam Karl-Liebknecht-Str. 24-25 14476 Potsdam OT Golm Germany
| | - Frieder W Scheller
- Institute of Biochemistry and Biology, University of Potsdam Karl-Liebknecht-Str. 24-25 14476 Potsdam OT Golm Germany
| | - Róbert E Gyurcsányi
- BME "Lendület" Chemical Nanosensors Research Group, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics Szt. Gellért tér 4 1111 Budapest Hungary
| |
Collapse
|
27
|
Gandhi M, Indiramma J, Jayaprakash NS, Kumar AS. An efficient electrochemical sandwich ELISA for urinary human serum albumin-biomarker based on highly redox-active thionine surface-confined MWCNT/PEDOT.PSS platform. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
28
|
Saeed U, Fatima B, Hussain D, Ashiq R, Naeem Ashiq M, Najam-ul-Haq M. CoTe nanorods based electrochemical sensor for quantitative detection of albumin from chronic kidney disease patients. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2021.115999] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
29
|
Paul KD, Rani S, Luxami V, Gupta S. A novel target and biomarker benzothiazolyl-naphthalimide probes for precisely and selective detection of serum albumin and anticancer activity. NEW J CHEM 2022. [DOI: 10.1039/d1nj03650e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
N-Benzothiazolyl-1,8-naphthalimide based fluorescence probes were designed and synthesized for selective detection of human serum albumin (HSA) and Bovine serum albumin (BSA) among various bioanalytes and further studied for their in...
Collapse
|
30
|
Mustafa YL, Keirouz A, Leese HS. Molecularly Imprinted Polymers in Diagnostics: Accessing Analytes in Biofluids. J Mater Chem B 2022; 10:7418-7449. [DOI: 10.1039/d2tb00703g] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Bio-applied molecularly imprinted polymers (MIPs) are biomimetic materials with tailor-made synthetic recognition sites, mimicking biological counterparts known for their sensitive and selective analyte detection. MIPs, specifically designed for biomarker analysis...
Collapse
|
31
|
Luo Y, Yu QQ, Gao JJ, Lang XX, Li HY, Yu XF, Qi XY, Wang MQ. Design, synthesis and mechanistic studies of a TICT based fluorogenic probe for lighting up protein HSA. Bioorg Med Chem Lett 2021; 53:128438. [PMID: 34740774 DOI: 10.1016/j.bmcl.2021.128438] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2021] [Revised: 10/05/2021] [Accepted: 10/28/2021] [Indexed: 01/11/2023]
Abstract
Human serum albumin (HSA) in blood serves as an important biomarker for clinical diagnosis, and fluorescence sensing method has attracted extensive attention. In this work, a small organic molecule probe, YS8, involving twisted intramolecular charge transfer (TICT) characteristic, was designed and investigated to detect HSA. YS8 kept silent state in fluorescence under physiological conditions, but the encapsulation of YS8 in the hydrophobic subdomain IB region of HSA inhibited the TICT state and produced a clear light-up fluorescent signal. Especially, YS8 was demonstrated to be an efficient fluorogenic probe to discriminate HSA from other proteins including the bovine serum albumin (BSA). Moreover, YS8/HSA complex could be applied in fluorescence imaging in living cells and is also useful in the study of artificial fluorescent protein (AFP).
Collapse
Affiliation(s)
- Yang Luo
- School of Pharmacy, Jiangsu University, Zhenjiang 212013, PR China
| | - Quan-Qi Yu
- School of Pharmacy, Jiangsu University, Zhenjiang 212013, PR China
| | - Juan-Juan Gao
- School of Pharmacy, Jiangsu University, Zhenjiang 212013, PR China
| | - Xue-Xian Lang
- School of Pharmacy, Jiangsu University, Zhenjiang 212013, PR China
| | - Hong-Yao Li
- School of Pharmacy, Jiangsu University, Zhenjiang 212013, PR China
| | - Xiao-Feng Yu
- School of Pharmacy, Jiangsu University, Zhenjiang 212013, PR China
| | - Xue-Yong Qi
- School of Pharmacy, Jiangsu University, Zhenjiang 212013, PR China
| | - Ming-Qi Wang
- School of Pharmacy, Jiangsu University, Zhenjiang 212013, PR China.
| |
Collapse
|
32
|
Ultrasensitive detection and removal of carbamazepine in wastewater using UCNPs functionalized with thin-shell MIPs. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106674] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
33
|
Ashiq R, Fatima B, Shah M, Hussain D, Mohyuddin A, Majeed S, Mehmood R, Imran M, Ashiq MN, Najam-Ul-Haq M. Tin derived antimony/nitrogen-doped porous carbon (Sb/NPC) composite for electrochemical sensing of albumin from hepatocellular carcinoma patients. Mikrochim Acta 2021; 188:338. [PMID: 34510324 DOI: 10.1007/s00604-021-05005-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Accepted: 08/24/2021] [Indexed: 01/22/2023]
Abstract
An electrochemical sensor based on an antimony/nitrogen-doped porous carbon (Sb/NPC) composite has been developed for the quantitative detection of albumin from hepatocellular carcinoma (HCC) patients. Sb/NPC is hydrothermally synthesized from Sn/NPC precursors. The synthesized precursor (Sn/NPC) and the product (Sb/NPC) are characterized by XRD, FTIR, TGA, UV/Vis, SEM, and AFM. Cyclic voltammetry, chronoamperometry, and electrochemical impedance studies are used to investigate the electrochemical performance of Sb/NPC-GCE. Sb/NPC-GCE detects albumin at physiological pH of 7.4 in the potential range 0.92 V and 0.09 V for oxidation and reduction, respectively. LOD and recovery of Sb/NPC-GCE for the determination of albumin are 0.13 ng.mL-1 and 66.6 ± 0.97-100 ± 2.73%, respectively. Chronoamperometry of the modified working electrode demonstrates its stability for 14 h, indicating its reusability and reproducibility. Sb/NPC-GCE is a selective sensor for albumin detection in the presence of interfering species. The electrode has been applied for albumin detection in human serum samples of HCC patients. A negative correlation of albumin with alpha-fetoprotein levels in HCC patients is observed by statistical analysis.
Collapse
Affiliation(s)
- Rabia Ashiq
- Department of Biochemistry, Bahauddin Zakariya University, Multan, 60800, Pakistan
| | - Batool Fatima
- Department of Biochemistry, Bahauddin Zakariya University, Multan, 60800, Pakistan.
| | - Mohibullah Shah
- Department of Biochemistry, Bahauddin Zakariya University, Multan, 60800, Pakistan
| | - Dilshad Hussain
- HEJ Research Institute of Chemistry, International Center for Chemical and Biological Sciences, University of Karachi, Karachi, 75270, Pakistan
| | - Abrar Mohyuddin
- Department of Chemistry, The Emerson University, Multan, Pakistan
| | - Saadat Majeed
- Institute of Chemical Sciences, Bahauddin Zakariya University, Multan, 60800, Pakistan
| | - Rubaida Mehmood
- MINAR Cancer Hospital, Pakistan Atomic Energy Commission, Multan, Pakistan
| | - Muhammad Imran
- Biochemistry Section, Institute of Chemical Sciences, University of Peshawar, Peshawar, 25120, Pakistan
| | - Muhammad Naeem Ashiq
- Institute of Chemical Sciences, Bahauddin Zakariya University, Multan, 60800, Pakistan
| | - Muhammad Najam-Ul-Haq
- Institute of Chemical Sciences, Bahauddin Zakariya University, Multan, 60800, Pakistan.
| |
Collapse
|
34
|
Phoonsawat K, Khachornsakkul K, Ratnarathorn N, Henry CS, Dungchai W. Distance-Based Paper Device for a Naked-Eye Albumin-to-Alkaline Phosphatase Ratio Assay. ACS Sens 2021; 6:3047-3055. [PMID: 34308636 DOI: 10.1021/acssensors.1c01058] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The albumin-to-alkaline phosphatase ratio (AAPR) has been a cancer prognostic indicator. This paper presents the concept of a dual-color change distance-based paper device (dPAD) for albumin (Alb) and alkaline phosphatase (ALP) detection to evaluate this cancer prognostic index. Whereas Alb interacts with the bromocresol green (BCG) indicator to form a bluish-green complex, ALP hydrolyzes l-ascorbic acid-2-phosphate (AAP) to produce ascorbic acid (AA), which reacts with KIO3 to generate I2 and I-. I2/I- reacts with silver hexagonal nanoprisms (purple color) in the presence of Cu2+, resulting in a color change from purple to colorless. The distance of the color change from yellow to the bluish-green and purple to colorless correlates to Alb and ALP concentration, respectively. The angle index for the AAPR is then defined by drawing a straight line that connects the tops of the two changed band lengths in the detection area. The highest bluish-green color band length on the Alb region is the midpoint, which is the position set of the protractor at 0°, and the angle is measured using a simple protractor. The results indicate that an AAPR below 0.57 will have an angle greater than 40° and correlates with a risk factor for lung cancer. The naked-eye detection limits for Alb and ALP were found to be 0.8 g/L and 5 U/L (n = 10), respectively. The practical application of the developed dPAD was successfully demonstrated by Alb and ALP analysis in human serum and validated against standard methods. The proposed method does not require incubation conditions for the ALP assay, which strongly reduces the overall analysis steps and time. Moreover, our device provides a low-cost, simple, sensitive, selective, accurate, and precise determination of the AAPR.
Collapse
Affiliation(s)
- Kamonchanok Phoonsawat
- Organic Synthesis, Electrochemistry & Natural Product Research Unit, Department of Chemistry, Faculty of Science, King Mongkut’s University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| | - Kawin Khachornsakkul
- Organic Synthesis, Electrochemistry & Natural Product Research Unit, Department of Chemistry, Faculty of Science, King Mongkut’s University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| | - Nalin Ratnarathorn
- Organic Synthesis, Electrochemistry & Natural Product Research Unit, Department of Chemistry, Faculty of Science, King Mongkut’s University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| | - Charles S. Henry
- Departments of Chemistry and Chemical & Biological Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Wijitar Dungchai
- Organic Synthesis, Electrochemistry & Natural Product Research Unit, Department of Chemistry, Faculty of Science, King Mongkut’s University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
- Applied Science & Engineering for Social Solution Unit, Faculty of Science, King Mongkut’s University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| |
Collapse
|
35
|
Romanholo PVV, Razzino CA, Raymundo-Pereira PA, Prado TM, Machado SAS, Sgobbi LF. Biomimetic electrochemical sensors: New horizons and challenges in biosensing applications. Biosens Bioelectron 2021; 185:113242. [PMID: 33915434 DOI: 10.1016/j.bios.2021.113242] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 04/05/2021] [Accepted: 04/07/2021] [Indexed: 12/12/2022]
Abstract
The urge to meet the ever-growing needs of sensing technology has spurred research to look for new alternatives to traditional analytical methods. In this scenario, the glucometer is the flagship of commercial electrochemical sensing platforms, combining selectivity, reliability and portability. However, other types of enzyme-based biosensors seldom achieve the market, in spite of the large and increasing number of publications. The reasons behind their commercial limitations concern enzyme denaturation, and the high costs associated with procedures for their extraction and purification. In this sense, biomimetic materials that seek to imitate the desired properties of natural enzymes and biological systems have come out as an appealing path for robust and sensitive electrochemical biosensors. We herein portray the historical background of these biomimicking materials, covering from their beginnings until the most impactful applications in the field of electrochemical sensing platforms. Throughout the discussion, we present and critically appraise the major benefits and the most significant drawbacks offered by the bioinspired systems categorized as Nanozymes, Synzymes, Molecularly Imprinted Polymers (MIPs), Nanochannels, and Metal Complexes. Innovative strategies of fabrication and challenging applications are further reviewed and evaluated. In the end, we ponder over the prospects of this emerging field, assessing the most critical issues that shall be faced in the coming decade.
Collapse
Affiliation(s)
- Pedro V V Romanholo
- Instituto de Química, Universidade Federal de Goiás, Goiânia, GO, 74690-900, Brazil
| | - Claudia A Razzino
- Instituto de Pesquisa e Desenvolvimento, Universidade Do Vale Do Paraíba, São José Dos Campos, SP, 12244-000, Brazil
| | | | - Thiago M Prado
- Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, SP, 13566-590, Brazil
| | - Sergio A S Machado
- Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, SP, 13566-590, Brazil
| | - Livia F Sgobbi
- Instituto de Química, Universidade Federal de Goiás, Goiânia, GO, 74690-900, Brazil.
| |
Collapse
|
36
|
Lakard S, Pavel IA, Lakard B. Electrochemical Biosensing of Dopamine Neurotransmitter: A Review. BIOSENSORS 2021; 11:179. [PMID: 34204902 PMCID: PMC8229248 DOI: 10.3390/bios11060179] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 05/31/2021] [Accepted: 06/01/2021] [Indexed: 12/17/2022]
Abstract
Neurotransmitters are biochemical molecules that transmit a signal from a neuron across the synapse to a target cell, thus being essential to the function of the central and peripheral nervous system. Dopamine is one of the most important catecholamine neurotransmitters since it is involved in many functions of the human central nervous system, including motor control, reward, or reinforcement. It is of utmost importance to quantify the amount of dopamine since abnormal levels can cause a variety of medical and behavioral problems. For instance, Parkinson's disease is partially caused by the death of dopamine-secreting neurons. To date, various methods have been developed to measure dopamine levels, and electrochemical biosensing seems to be the most viable due to its robustness, selectivity, sensitivity, and the possibility to achieve real-time measurements. Even if the electrochemical detection is not facile due to the presence of electroactive interfering species with similar redox potentials in real biological samples, numerous strategies have been employed to resolve this issue. The objective of this paper is to review the materials (metals and metal oxides, carbon materials, polymers) that are frequently used for the electrochemical biosensing of dopamine and point out their respective advantages and drawbacks. Different types of dopamine biosensors, including (micro)electrodes, biosensing platforms, or field-effect transistors, are also described.
Collapse
Affiliation(s)
| | | | - Boris Lakard
- Institut UTINAM, UMR CNRS 6213, University of Bourgogne Franche-Comté, 16 Route de Gray, 25030 Besançon, France; (S.L.); (I.-A.P.)
| |
Collapse
|
37
|
Dehdari Vais R, Yadegari H, Heli H, Sattarahmady N. A β-Amyloid (1-42) Biosensor Based on Molecularly Imprinted Poly-Pyrrole for Early Diagnosis of Alzheimer's Disease. J Biomed Phys Eng 2021; 11:215-228. [PMID: 33937128 PMCID: PMC8064131 DOI: 10.31661/jbpe.v0i0.1070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2018] [Accepted: 01/23/2019] [Indexed: 11/16/2022]
Abstract
Background: Alzheimer’s disease (AD) is a common form of dementia, characterized by production and deposition of β-amyloid peptide in the brain.
Thus, β-amyloid peptide is a potentially promising biomarker used to diagnose and monitor the progression of AD. Objective: The study aims to develop a biosensor based on a molecularly imprinted poly-pyrrole for detection of β-amyloid. Material and Methods: In this experimental study, an imprinted poly-pyrrole was employed as an artificial receptor synthesized by electro-polymerization of pyrrole
on screen-printed carbon electrodes in the presence of β-amyloid. β-amyloid acts as a molecular template within the polymer. The biosensor was
evaluated by cyclic voltammetry using ferro/ferricyanide marker. The parameters influencing the biosensor performance, including electro-polymerization
cycle umbers and β-amyloid binding time were optimized to achieve the best biosensor sensitivity. Results: The β-amyloid binding affinity with the biosensor surface was evaluated by the Freundlich isotherm, and Freundlich
constant and exponent were obtained as 0.22 ng mL-1 and 10.60, respectively. The biosensor demonstrated a detection limit of 1.2 pg mL-1.
The biosensor was applied for β-amyloid determination in artificial cerebrospinal fluid. Conclusion: The biosensor is applicable for early Alzheimer’s disease detection.
Collapse
Affiliation(s)
- Rezvan Dehdari Vais
- PhD Candidate, Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Hossein Yadegari
- PhD, Department of Mechanical and Materials Engineering, University of Western Ontario, London, Ontario N6A 5B9, Canada
| | - Hossein Heli
- PhD, Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Naghmeh Sattarahmady
- PhD, Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
- PhD, Department of Medical Physics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
38
|
Gutiérrez-Climente R, Clavié M, Dumy P, Mehdi A, Subra G. Sol-gel process: the inorganic approach in protein imprinting. J Mater Chem B 2021; 9:2155-2178. [PMID: 33624655 DOI: 10.1039/d0tb02941f] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Proteins play a central role in the signal transmission in living systems since they are able to recognize specific biomolecules acting as cellular receptors, antibodies or enzymes, being themselves recognized by other proteins in protein/protein interactions, or displaying epitopes suitable for antibody binding. In this context, the specific recognition of a given protein unlocks a range of interesting applications in diagnosis and in targeted therapies. Obviously, this role is already fulfilled by antibodies with unquestionable success. However, the design of synthetic artificial systems able to endorse this role is still challenging with a special interest to overcome limitations of antibodies, in particular their production and their stability. Molecular Imprinted Polymers (MIPs) are attractive recognition systems which could be an alternative for the specific capture of proteins in complex biological fluids. MIPs can be considered as biomimetic receptors or antibody mimics displaying artificial paratopes. However, MIPs of proteins remains a challenge due to their large size and conformational flexibility, their complex chemical nature with multiple recognition sites and their low solubility in most organic solvents. Classical MIP synthesis conditions result in large polymeric cavities and unspecific binding sites on the surface. In this review, the potential of the sol-gel process as inorganic polymerization strategy to overcome the drawbacks of protein imprinting is highlighted. Thanks to the mild and biocompatible experimental conditions required and the use of water as a solvent, the inorganic polymerization approach better suited to proteins than organic polymerization. Through numerous examples and applications of MIPs, we proposed a critical evaluation of the parameters that must be carefully controlled to achieve sol-gel protein imprinting (SGPI), including the choice of the monomers taking part in the polymerization.
Collapse
Affiliation(s)
| | | | - Pascal Dumy
- IBMM, Univ. Montpellier, CNRS, ENSCM, France.
| | - Ahmad Mehdi
- ICGM, Univ. Montpellier, CNRS, ENSCM, France
| | | |
Collapse
|
39
|
The Importance of Developing Electrochemical Sensors Based on Molecularly Imprinted Polymers for a Rapid Detection of Antioxidants. Antioxidants (Basel) 2021; 10:antiox10030382. [PMID: 33806514 PMCID: PMC8001462 DOI: 10.3390/antiox10030382] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 02/22/2021] [Accepted: 02/28/2021] [Indexed: 12/30/2022] Open
Abstract
This review aims to pin out the importance of developing a technique for rapid detection of antioxidants, based on molecular imprinting techniques. It covers three major areas that have made great progress over the years in the field of research, namely: antioxidants characterization, molecular imprinting and electrochemistry, alone or combined. It also reveals the importance of bringing these three areas together for a good evaluation of antioxidants in a simple or complex medium, based on selectivity and specificity. Although numerous studies have associated antioxidants with molecular imprinting, or antioxidants with electrochemistry, but even electrochemistry with molecular imprinting to valorize different compounds, the growing prominence of antioxidants in the food, medical, and paramedical sectors deserves to combine the three areas, which may lead to innovative industrial applications with satisfactory results for both manufacturers and consumers.
Collapse
|
40
|
Aptamer-functionalised magnetic particles for highly selective detection of urinary albumin in clinical samples of diabetic nephropathy and other kidney tract disease. Anal Chim Acta 2021; 1154:338302. [PMID: 33736810 DOI: 10.1016/j.aca.2021.338302] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 02/02/2021] [Accepted: 02/03/2021] [Indexed: 01/05/2023]
Abstract
We report a new highly selective detection platform for human albumin (HA) in urine based on aptamer-functionalised magnetic particles. Magnetic separation and re-dispersion was utilised to expose the HA-bound particles to a methylene blue solution. A second magnetic collection step was then used to allow the methylene blue supernatant to be reduced at an unmodified screen-printed electrode. Since methylene blue adsorbs to HA, the reduction current fell in proportion to HA concentration. There was no interference from compounds such as dopamine, epinephrine, vanillylmandelic acid, normetanephrine, metanephrine and creatinine in artificial urine at the concentrations at which they would be expected to appear. A calibration equation was derived to allow for the effect of pH on the response. This enabled measurement to be made directly in clinical urine samples of varying pH. After optimisation of experimental parameters, the total assay time was 40 min and the limit of detection was between 0.93 and 1.16 μg mL-1, depending on the pH used. HA could be detected up to 400 μg mL-1, covering the range from normoalbuminuria to macroalbuminuria. Analysis of urine samples of patients, with diabatic nephropathy, type I & II diabetes mellitus and chronic kidney disease, from a local hospital showed good agreement with the standard urinary human albumin detection method.
Collapse
|
41
|
Dong C, Shi H, Han Y, Yang Y, Wang R, Men J. Molecularly imprinted polymers by the surface imprinting technique. Eur Polym J 2021. [DOI: 10.1016/j.eurpolymj.2020.110231] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
42
|
Kalecki J, Iskierko Z, Cieplak M, Sharma PS. Oriented Immobilization of Protein Templates: A New Trend in Surface Imprinting. ACS Sens 2020; 5:3710-3720. [PMID: 33225686 PMCID: PMC7771019 DOI: 10.1021/acssensors.0c01634] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Accepted: 11/06/2020] [Indexed: 12/18/2022]
Abstract
In this Review, we have summarized recent trends in protein template imprinting. We emphasized a new trend in surface imprinting, namely, oriented protein immobilization. Site-directed proteins were assembled through specially selected functionalities. These efforts resulted in a preferably oriented homogeneous protein construct with decreased protein conformation changes during imprinting. Moreover, the maximum functionality for protein recognition was utilized. Various strategies were exploited for oriented protein immobilization, including covalent immobilization through a boronic acid group, metal coordinating center, and aptamer-based immobilization. Moreover, we have discussed the involvement of semicovalent as well as covalent imprinting. Interestingly, these approaches provided additional recognition sites in the molecular cavities imprinted. Therefore, these molecular cavities were highly selective, and the binding kinetics was improved.
Collapse
Affiliation(s)
- Jakub Kalecki
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland
| | - Zofia Iskierko
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland
| | - Maciej Cieplak
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland
| | - Piyush S. Sharma
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland
| |
Collapse
|
43
|
Abstract
This review describes the recent advances from the past five years concerning the development and applications of molecularly imprinted membranes (MIMs) in the field of sample treatment and separation processes. After a short introduction, where the importance of these materials is highlighted, a description of key aspects of membrane separation followed by the strategies of preparation of these materials is described. The review continues with several analytical applications of these MIMs for sample preparation as well as for separation purposes covering pharmaceutical, food, and environmental areas. Finally, a discussion focused on possible future directions of these materials in extraction and separation field is also given.
Collapse
|
44
|
Feyzi-barnaji B, Darbasizadeh B, Arkan E, Salehzadeh H, Salimi A, Nili F, Dinarvand R, Mohammadi A. Immunoreaction-triggered diagnostic device using reduced graphene oxide/CuO NPs/chitosan ternary nanocomposite, toward enhanced electrochemical detection of albumin. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114642] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
45
|
Morishita T, Yoshida A, Hayakawa N, Kiguchi K, Cheubong C, Sunayama H, Kitayama Y, Takeuchi T. Molecularly Imprinted Nanogels Possessing Dansylamide Interaction Sites for Controlling Protein Corona In Situ by Cloaking Intrinsic Human Serum Albumin. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2020; 36:10674-10682. [PMID: 32794751 DOI: 10.1021/acs.langmuir.0c00927] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Nanomaterials have become increasingly promising for biomedical applications owing to their specific biological characteristics. As drug delivery vehicles, nanomaterials have to circulate in the bloodstream to deliver the encapsulated components to the target tissues. Protein corona regulation is one of the promising approaches that gives stealth capability to avoid immune response. The aim of this study was to develop molecularly imprinted polymer nanogels (MIP-NGs) capable of protein corona regulation, using intrinsic human serum albumin (HSA) and with a functional monomer, dansylamide ethyl acrylamide (DAEAm), the dansylamide group serving as a ligand for HSA. The recognition capability of HSA for MIP-NGs was investigated by isothermal titration calorimetry (ITC). The affinity of the MIP-NGs prepared with DAEAm was then compared to that of the reference MIP-NGs prepared with pyrrolidyl acrylate developed in our previous study. Furthermore, we demonstrated that the concurrent use of these two different functional monomers for molecular imprinting was further effective to construct high-affinity recognition nanocavities for HSA and to form HSA-rich protein corona in the human plasma owing to the different interaction modes of the monomers. We believe that the molecular imprinting strategy developed through the use of ligand-based functional monomer is an effective strategy to create artificial molecular recognition materials.
Collapse
Affiliation(s)
- Takahiro Morishita
- Graduate School of Engineering, Kobe University, Nada-ku, Kobe 657-8501, Japan
| | - Aoi Yoshida
- Graduate School of Engineering, Kobe University, Nada-ku, Kobe 657-8501, Japan
| | - Natsuki Hayakawa
- Graduate School of Engineering, Kobe University, Nada-ku, Kobe 657-8501, Japan
| | - Kentaro Kiguchi
- Graduate School of Engineering, Kobe University, Nada-ku, Kobe 657-8501, Japan
| | - Chehasan Cheubong
- Graduate School of Engineering, Kobe University, Nada-ku, Kobe 657-8501, Japan
- Department of Chemistry, Faculty of Science and Technology, Rajamangala University of Technology Thanyaburi, Pathumthani 12110, Thailand
| | - Hirobumi Sunayama
- Graduate School of Engineering, Kobe University, Nada-ku, Kobe 657-8501, Japan
| | - Yukiya Kitayama
- Graduate School of Engineering, Osaka Prefecture University, 1-1, Gakuen-cho, Naka-ku, Sakai, Osaka 599-8531, Japan
| | - Toshifumi Takeuchi
- Graduate School of Engineering, Kobe University, Nada-ku, Kobe 657-8501, Japan
- Center for Advanced Medical Engineering Research & Development (CAMED), Kobe University, Chuo-ku, Kobe 650-0047, Japan
| |
Collapse
|
46
|
Abbasy L, Mohammadzadeh A, Hasanzadeh M, Razmi N. Development of a reliable bioanalytical method based on prostate specific antigen trapping on the cavity of molecular imprinted polymer towards sensing of PSA using binding affinity of PSA-MIP receptor: A novel biosensor. J Pharm Biomed Anal 2020; 188:113447. [PMID: 32623317 DOI: 10.1016/j.jpba.2020.113447] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Revised: 06/21/2020] [Accepted: 06/23/2020] [Indexed: 11/24/2022]
Abstract
In this study, electrically-conducting poly [Toluidine Blue (PTB)] was applied as artificial receptor. It was organized by molecular imprinting approaches and via electrochemical technique for the sensitive monitoring of prostate-specific antigen (PSA). The protein-imprinted PTB was electropolymerized in a pre-formed glutaraldehyde-cysteamine (GA-Cys A) matrix on the surface of gold electrode, which significantly boosted the stability against degradation of the Molecular Imprinted Polymer (MIP) on the surface of pre-modified gold electrode. Moreover, the MIP bio-receptor ability towards protein recognition was explored by some electrochemical techniques. The binding affinity of MIP system was considerably upper than that of non-imprinted polymer (NIP) system, indicating the success of the method in generating imprinted materials that was specifically use to PSA protein. The incubation of the MIP modified electrode in various concentration of PSA (from 1-60 μg/L) resulted in the increase of the Fe (CN)63-/4- redox peak current. The bio-device also showed linear response from 1-60 μg/L and LLOQ of 1 μg/L by using DPV technique, leading to PSA monitoring in clinical samples. The proposed MIP-based biosensor was satisfactorily applied to the determination of PSA in human plasma samples. Therefore, the developed bio-device provides a new approach for sensitive, simple, rapid, and cost-effective monitoring of 1 μg/L of PSA. Notably, this approach could appear as an appropriate candidate for point-of-care (POC) use in clinical and biomedical analyses.
Collapse
Affiliation(s)
- Leila Abbasy
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; Nutrition Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Arezoo Mohammadzadeh
- Liver and Gastrointestinal Diseases Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; Hematology-Oncology Research Center, Tabriz University of Medical Sciences, Tabriz, 51664, Iran; Tuberculosis and Lung Disease Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; Endocrinology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mohammad Hasanzadeh
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| | - Nasrin Razmi
- Department of Science and Technology, Physics, Electronics and Mathematics Linköping University, Sweden
| |
Collapse
|
47
|
Protein Determination with Molecularly Imprinted Polymer Recognition Combined with Birefringence Liquid Crystal Detection. SENSORS 2020; 20:s20174692. [PMID: 32825278 PMCID: PMC7547379 DOI: 10.3390/s20174692] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 08/14/2020] [Accepted: 08/17/2020] [Indexed: 11/17/2022]
Abstract
Liquid crystal-based sensors offer the advantage of high sensitivity at a low cost. However, they often lack selectivity altogether or require costly and unstable biomaterials to impart this selectivity. To incur this selectivity, we herein integrated a molecularly imprinted polymer (MIP) film recognition unit with a liquid crystal (LC) in an optical cell transducer. We tested the resulting chemosensor for protein determination. We examined two different LCs, each with a different optical birefringence. That way, we revealed the influence of that parameter on the sensitivity of the (human serum albumin)-templated (MIP-HSA) LC chemosensor. The response of this chemosensor with the (MIP-HSA)-recognizing film was linear from 2.2 to 15.2 µM HSA, with a limit of detection of 2.2 µM. These values are sufficient to use the devised chemosensor for HSA determination in biological samples. Importantly, the imprinting factor (IF) of this chemosensor was appreciable, reaching IF = 3.7. This IF value indicated the predominant binding of the HSA through specific rather than nonspecific interactions with the MIP.
Collapse
|
48
|
Velasco-Rodriguez B, Soltero-Martínez JF, Rosales-Rivera LC, Macías-Balleza ER, Landázuri G, Larios-Durán ER. Adsorption and Interaction of Bovine Serum Albumin and Pluronic P103 Triblock Copolymer on a Gold Electrode: Double-Layer Capacitance Measurements. ACS OMEGA 2020; 5:17347-17355. [PMID: 32715219 PMCID: PMC7377067 DOI: 10.1021/acsomega.0c01704] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Accepted: 06/25/2020] [Indexed: 06/11/2023]
Abstract
The interactions of proteins and other molecules and their adsorption onto substrates is a fascinating topic that has been applied to surface technologies, biosensors, corrosion studies, biotechnologies, and other fields. The success of these applications requires a previous characterization using some analytical techniques that, ordinarily, are not electrochemical. This work proposes analyzing the variation of the double-layer capacitance obtained through impedance electrochemical spectroscopy as an alternative strategy to show evidence of the interactions between proteins and triblock copolymers. The proposal is supported through the study of the interaction and adsorption of bovine serum albumin (BSA) and a commercial triblock copolymer (P103) in phosphate buffer on a gold electrode. The double-layer capacitance and the apparent interface thickness vs polarization potential curves as well as the potential of zero charge for pure P103 (0.6 wt %, corresponding to 6 g L-1), pure BSA (3 mg mL-1), and P103-BSA solutions (0.6 wt % and 3 mg mL-1, respectively) are sensitive enough to show not only the interaction and the adsorption of the species but also the polarization potential where these interactions are taking place. A qualitative and quantitative analysis concerning the double-layer capacitance behavior is given. The significance and impact of this work is also presented.
Collapse
|
49
|
Choosang J, Thavarungkul P, Kanatharana P, Numnuam A. AuNPs/PpPD/PEDOT:PSS-Fc modified screen-printed carbon electrode label-free immunosensor for sensitive and selective determination of human serum albumin. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104709] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
50
|
Yarman A, Scheller FW. How Reliable Is the Electrochemical Readout of MIP Sensors? SENSORS (BASEL, SWITZERLAND) 2020; 20:E2677. [PMID: 32397160 PMCID: PMC7248831 DOI: 10.3390/s20092677] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 05/01/2020] [Accepted: 05/06/2020] [Indexed: 01/15/2023]
Abstract
Electrochemical methods offer the simple characterization of the synthesis of molecularly imprinted polymers (MIPs) and the readouts of target binding. The binding of electroinactive analytes can be detected indirectly by their modulating effect on the diffusional permeability of a redox marker through thin MIP films. However, this process generates an overall signal, which may include nonspecific interactions with the nonimprinted surface and adsorption at the electrode surface in addition to (specific) binding to the cavities. Redox-active low-molecular-weight targets and metalloproteins enable a more specific direct quantification of their binding to MIPs by measuring the faradaic current. The in situ characterization of enzymes, MIP-based mimics of redox enzymes or enzyme-labeled targets, is based on the indication of an electroactive product. This approach allows the determination of both the activity of the bio(mimetic) catalyst and of the substrate concentration.
Collapse
Affiliation(s)
- Aysu Yarman
- Institute of Biochemistry and Biology, University of Potsdam, Karl-Liebknecht-Strasse 24-25, 14476 Potsdam, Germany
| | - Frieder W. Scheller
- Institute of Biochemistry and Biology, University of Potsdam, Karl-Liebknecht-Strasse 24-25, 14476 Potsdam, Germany
| |
Collapse
|