1
|
Dehghandehnavi F, Sajal MS, Dandin M. Surface-modified CMOS biosensors. Front Bioeng Biotechnol 2024; 12:1441430. [PMID: 39569164 PMCID: PMC11576298 DOI: 10.3389/fbioe.2024.1441430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2024] [Accepted: 10/09/2024] [Indexed: 11/22/2024] Open
Abstract
Biosensors translate biological events into electronic signals that quantify biological processes. They are increasingly used in in vitro diagnostics applications that leverage their ability to process small sample volumes. One recent trend has been to integrate biosensors with complementary metal-oxide-semiconductor (CMOS) chips to provide enhanced miniaturization, parallel sensing, and low power consumption at a low cost. CMOS-enabled biosensors are used in monitoring DNA hybridization, enzymatic reactions, and cell proliferation, to name a few applications. This paper explores the materials and processes used in emerging CMOS biosensors. We discuss subtractive and additive processes for creating electrodes for electrochemical sensing applications. We discuss functionalization techniques for creating bioelectronic interfaces that allow molecular events to be transduced into the electrical domain using a plurality of modalities that are readily provided by CMOS chips. Example modalities featured are optical sensing, electrochemical detection, electrical detection, magnetic sensing, and mechanical sensing.
Collapse
Affiliation(s)
- Fahimeh Dehghandehnavi
- Electrical and Computer Engineering Department, Integrated Circuits and Bioengineering Laboratory, Carnegie Mellon University, Pittsburgh, PA, United States
| | - Md Sakibur Sajal
- Electrical and Computer Engineering Department, Integrated Circuits and Bioengineering Laboratory, Carnegie Mellon University, Pittsburgh, PA, United States
| | - Marc Dandin
- Electrical and Computer Engineering Department, Integrated Circuits and Bioengineering Laboratory, Carnegie Mellon University, Pittsburgh, PA, United States
| |
Collapse
|
2
|
Pohanka M, Zakova J. Urine Test Strip Quantitative Assay with a Smartphone Camera. Int J Anal Chem 2024; 2024:6004970. [PMID: 38529171 PMCID: PMC10963100 DOI: 10.1155/2024/6004970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 02/26/2024] [Accepted: 03/12/2024] [Indexed: 03/27/2024] Open
Abstract
Urine test strips for urinalysis are a common diagnostic tool with minimal costs and are used in various situations including homecare and hospitalization. The coloration scaled by the naked eye is simple, but it is suitable for semiquantitative analysis only. In this paper, a colorimetric assay is developed based on a smartphone digital camera and urine test strips. Assays of pH, albumin, glucose, and lipase activity were performed as a tool for the diagnosis of aciduria, alkaluria, glycosuria, proteinuria, and leukocyturia. The RGB color channels were analyzed in the colorimetric assay, and the assay exerted good sensitivity, and all the particular diagnoses proved to be reliable. The limits of detection for glucose (0.11 mmol/L), albumin (0.15 g/L), and lipase (2.50 U/μL) were low enough to cover the expected physiological concentration, and the range for pH was also satisfactory. The urine test strips with a camera as an output detector proved applicability to spiked urine samples, and the results were also well in comparison to the standard assays which confirms the practical relevance of the presented findings.
Collapse
Affiliation(s)
- Miroslav Pohanka
- Military Faculty of Medicine, University of Defence, Trebesska 1575, Hradec Kralove 50001, Czech Republic
| | - Jitka Zakova
- Military Faculty of Medicine, University of Defence, Trebesska 1575, Hradec Kralove 50001, Czech Republic
| |
Collapse
|
3
|
Zhang J, Xiao M, Su RG, Kong T, Zhang D, Zhou CW, Cheng GS. Silicon nanowire FET biosensor and its application in acute myocardial infarction. NANOTECHNOLOGY 2023; 35:112001. [PMID: 38081075 DOI: 10.1088/1361-6528/ad1438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 12/11/2023] [Indexed: 12/28/2023]
Abstract
Over the last two decades, silicon nanowire field-effect transistors (SiNW-FETs) with prominent merits of high surface-to-volume ratio, excellent biocompatibility and mature fabrication with standard silicon technology, have been widely studied as ultrahigh sensitive biosensors for the detection of target biomolecules, such as proteins, nucleic acids, cells and viruses so on. Herein we present a comprehensive review of the fundamental aspects of SiNW-FET biosensors, involving the working principle and the device fabrication, surface functionalization, and system integration with fluid exchange and electrical detection. Futhermore, we emphatically discuss the electrical detection of cardiac-specific biomarkers related to acute myocardial infarction disease. SiNW-FET biosensors are being increasingly exploited as promising diagnostic devices, which provide high sensitivity, high integration density, high speed sampling, strong specificity, and real-time and label-free detection for simple and cheap clinical testing.
Collapse
Affiliation(s)
- J Zhang
- College of Electronic and Information Engineering, Changshu Institute of Technology, Changshu 215500, People's Republic of China
| | - M Xiao
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, People's Republic of China
| | - R G Su
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, People's Republic of China
| | - T Kong
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, People's Republic of China
| | - D Zhang
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, People's Republic of China
| | - C W Zhou
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, CA 90089, United States of America
| | - G S Cheng
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, People's Republic of China
| |
Collapse
|
4
|
Raja L, Venkatesan S, Lin MC, Vediappen P. Green synthesis of naphthyl derivative as an optical sensor for the detection of l-carnitine in food samples. LUMINESCENCE 2023; 38:224-231. [PMID: 36602149 DOI: 10.1002/bio.4436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2022] [Revised: 01/02/2023] [Accepted: 01/03/2023] [Indexed: 01/06/2023]
Abstract
An economical and green approach to the synthesis of naphthyl derivative for detection of l-carnitine (3-hydroxy-4-N-trimethyl-aminobutyrate) is practically important. We developed a naphthyl derivative as a probe showing 'turn-on' response towards l-carnitine selectively at pH 7.2 through ICT mechanism with a good limit of detection (LOD) of 0.126 μM. Using Job's plot for determining the binding stoichiometry, it was found that probe could form a more stable complex (1:1) with carnitine. The binding constant (K) between probe and carnitine was calculated as 8 × 107 M-1 using the Benesi-Hildebrand plot. The binding interaction of the probe with l-carnitine was confirmed by nuclear magnetic resonance titrations, Fourier-transform infrared spectroscopy, photo physical studies and density functional theory calculations. Meanwhile, the probe can be used to quantitatively detect carnitine in food samples.
Collapse
Affiliation(s)
- Lavanya Raja
- Department of Organic Chemistry, School of Chemistry, Madurai Kamaraj University, Madurai, Tamilnadu, India
| | - Srinivasadesikan Venkatesan
- Department of Chemistry, Department of Sciences and Humanities, Vignan's Foundation for Science Technology and Research, Guntur, Andhra Pradesh, India
| | - Ming-Chang Lin
- Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
| | - Padmini Vediappen
- Department of Organic Chemistry, School of Chemistry, Madurai Kamaraj University, Madurai, Tamilnadu, India
| |
Collapse
|
5
|
Yamaguchi H, Miyazaki M. Enzyme-immobilized microfluidic devices for biomolecule detection. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
6
|
Tango R, Koeda A, Nagamine K, Tokito S, Niwa O, Ishikawa S, Sugimoto M. Development of a highly sensitive Prussian-blue-based enzymatic biosensor for L-carnitine employing the thiol/disulfide exchange reaction. ANAL SCI 2022; 38:963-968. [PMID: 35578012 DOI: 10.1007/s44211-022-00122-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Accepted: 04/23/2022] [Indexed: 11/01/2022]
Abstract
This is the first report of conducting proof-of-concept study for amperometric acetyltransferase-based L-carnitine sensor by employing the thiol/disulfide exchange reaction. The carnitine acetyltransferase (CrAT) catalyzes the reaction between acetyl-CoA and L-carnitine to produce CoA which is difficult to detect directly by electrochemical methods owing to steric hindrance and electrostatic effect of CoA. The thiol/disulfide exchange reaction between CoA and cystamine was mediated in the enzymatic reaction to produce electrochemically detectable low molecular weight of cationic cysteamine. The sensor exhibited high sensitivity and selectivity for L-carnitine in the concentration range 0.28-50 µM with a limit of detection of 0.28 µM. This is a promising strategy for L-carnitine sensing in point-of-care testing applications.
Collapse
Affiliation(s)
- Ryota Tango
- Graduate School of Organic Materials Science, Yamagata University, 4-3-16, Jonan, Yonezawa, 992-8510, Yamagata, Japan
| | - Aya Koeda
- Graduate School of Organic Materials Science, Yamagata University, 4-3-16, Jonan, Yonezawa, 992-8510, Yamagata, Japan
| | - Kuniaki Nagamine
- Graduate School of Organic Materials Science, Yamagata University, 4-3-16, Jonan, Yonezawa, 992-8510, Yamagata, Japan.
| | - Shizuo Tokito
- Graduate School of Organic Materials Science, Yamagata University, 4-3-16, Jonan, Yonezawa, 992-8510, Yamagata, Japan
| | - Osamu Niwa
- Saitama Institute of Technology, 1690, Fusaiji, Fukaya, 369-0293, Saitama, Japan
| | - Shigeo Ishikawa
- Department of Dentistry, Oral and Maxillofacial Plastic and Reconstructive Surgery, Faculty of Medicine, Yamagata University, 2-2-2, lida-nishi, Yamagata, 990-9585, Japan
| | - Masahiro Sugimoto
- Research and Development Center for Minimally Invasive Therapies, Institute of Medical Science, Tokyo Medical University, 6-1-1, Shinjuku, Tokyo, 160-0023, Japan
| |
Collapse
|
7
|
Field-Effect Capacitors Decorated with Ligand-Stabilized Gold Nanoparticles: Modeling and Experiments. BIOSENSORS 2022; 12:bios12050334. [PMID: 35624635 PMCID: PMC9139043 DOI: 10.3390/bios12050334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 05/10/2022] [Accepted: 05/11/2022] [Indexed: 11/17/2022]
Abstract
Nanoparticles are recognized as highly attractive tunable materials for designing field-effect biosensors with enhanced performance. In this work, we present a theoretical model for electrolyte-insulator-semiconductor capacitors (EISCAP) decorated with ligand-stabilized charged gold nanoparticles. The charged AuNPs are taken into account as additional, nanometer-sized local gates. The capacitance-voltage (C–V) curves and constant-capacitance (ConCap) signals of the AuNP-decorated EISCAPs have been simulated. The impact of the AuNP coverage on the shift of the C–V curves and the ConCap signals was also studied experimentally on Al–p-Si–SiO2 EISCAPs decorated with positively charged aminooctanethiol-capped AuNPs. In addition, the surface of the EISCAPs, modified with AuNPs, was characterized by scanning electron microscopy for different immobilization times of the nanoparticles.
Collapse
|
8
|
Recent advances in ion‐sensitive field‐effect transistors for biosensing applications. ELECTROCHEMICAL SCIENCE ADVANCES 2022. [DOI: 10.1002/elsa.202100163] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
|
9
|
Annese VF, Giagkoulovits C, Hu C, Al-Rawhani MA, Grant J, Patil SB, Cumming DRS. Micromolar Metabolite Measurement in an Electronically Multiplexed Format. IEEE Trans Biomed Eng 2022; 69:2715-2722. [PMID: 35104208 DOI: 10.1109/tbme.2022.3147855] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The detection of metabolites such as choline in blood are important in clinical care for patients with cancer and cardiovascular disease. Choline is only present in human blood at low concentrations hence accurate measurement in an affordable point-of-care format is extremely challenging. Integration of microfluidics on to complementary metal-oxide semiconductor (CMOS) technology has the potential to enable advanced sensing technologies with extremely low limit of detection that are well suited to multiple clinical metabolite measurements. Although CMOS and microfluidics are individually mature technologies, their integration has presented challenges that we overcome in a novel, cost-effective, single-step process. To demonstrate the process, we present the microfluidic integration of a metabolomics-on-CMOS point-of-care platform with four capillary microfluidic channels on top of a CMOS optical sensor array. The fabricated device was characterised to verify the required structural profile, mechanical strength, optical spectra, and fluid flow. As a proof of concept, we used the device for the in-vitro quantification of choline in human blood plasma with a limit of detection of 3.2 M and a resolution of 1.6 M.
Collapse
|
10
|
Wang Y, Yang M, Wu C. Design and Implementation of a pH Sensor for Micro Solution Based on Nanostructured Ion-Sensitive Field-Effect Transistor. SENSORS 2020; 20:s20236921. [PMID: 33287342 PMCID: PMC7730613 DOI: 10.3390/s20236921] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Revised: 11/29/2020] [Accepted: 12/01/2020] [Indexed: 12/19/2022]
Abstract
pH sensors based on a nanostructured ion-sensitive field-effect transistor have characteristics such as fast response, high sensitivity and miniaturization, and they have been widely used in biomedicine, food detection and disease monitoring. However, their performance is affected by many factors, such as gate dielectric material, channel material and channel thickness. In order to obtain a pH sensor with high sensitivity and fast response, it is necessary to determine the appropriate equipment parameters, which have high processing cost and long production time. In this study, a nanostructured ion-sensitive field-effect transistor was developed based on the SILVACO technology computer-aided design (TCAD) simulator. Through experiments, we analyzed the effects of the gate dielectric material, channel material and channel thickness on the electrical characteristics of the nanostructured field-effect transistor. Based on simulation results, silicon nitride was selected as the gate dielectric layer, while indium oxide was chosen as the channel layer. The structure and parameters of the dual channel ion-sensitive field-effect transistor were determined and discussed in detail. Finally, according to the simulation results, a pH sensor based on the nanostructured ion-sensitive field-effect transistor was fabricated. The accuracy of simulation results was verified by measuring the output, transfer and pH characteristics of the device. The fabricated pH sensor had a subthreshold swing as low as 143.19 mV/dec and obtained an actual sensitivity of 88.125 mV/pH. In addition, we also tested the oxidation reaction of hydrogen peroxide catalyzed by horseradish peroxidase, and the sensitivity was up to 144.26 pA mol−1 L−1, verifying that the ion-sensitive field-effect transistor (ISFET) can be used to detect the pH of micro solution, and then combine the enzyme-linked assay to detect the concentration of protein, DNA, biochemical substances, biomarkers, etc.
Collapse
|
11
|
Sadighbayan D, Hasanzadeh M, Ghafar-Zadeh E. Biosensing based on field-effect transistors (FET): Recent progress and challenges. Trends Analyt Chem 2020; 133:116067. [PMID: 33052154 PMCID: PMC7545218 DOI: 10.1016/j.trac.2020.116067] [Citation(s) in RCA: 108] [Impact Index Per Article: 21.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The use of field-Effect-Transistor (FET) type biosensing arrangements has been highlighted by researchers in the field of early biomarker detection and drug screening. Their non-metalized gate dielectrics that are exposed to an electrolyte solution cover the semiconductor material and actively transduce the biological changes on the surface. The efficiency of these novel devices in detecting different biomolecular analytes in a real-time, highly precise, specific, and label-free manner has been validated by numerous research studies. Considerable progress has been attained in designing FET devices, especially for biomedical diagnosis and cell-based assays in the past few decades. The exceptional electronic properties, compactness, and scalability of these novel tools are very desirable for designing rapid, label-free, and mass detection of biomolecules. With the incorporation of nanotechnology, the performance of biosensors based on FET boosts significantly, particularly, employment of nanomaterials such as graphene, metal nanoparticles, single and multi-walled carbon nanotubes, nanorods, and nanowires. Besides, their commercial availability, and high-quality production on a large-scale, turn them to be one of the most preferred sensing and screening platforms. This review presents the basic structural setup and working principle of different types of FET devices. We also focused on the latest progression regarding the use of FET biosensors for the recognition of viruses such as, recently emerged COVID-19, Influenza, Hepatitis B Virus, protein biomarkers, nucleic acids, bacteria, cells, and various ions. Additionally, an outline of the development of FET sensors for investigations related to drug development and the cellular investigation is also presented. Some technical strategies for enhancing the sensitivity and selectivity of detection in these devices are addressed as well. However, there are still certain challenges which are remained unaddressed concerning the performance and clinical use of transistor-based point-of-care (POC) instruments; accordingly, expectations about their future improvement for biosensing and cellular studies are argued at the end of this review.
Collapse
Affiliation(s)
- Deniz Sadighbayan
- Biologically Inspired Sensors and Actuators (BioSA), Faculty of Science, Dept. of Biology, York University, Toronto, Canada
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mohammad Hasanzadeh
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Ebrahim Ghafar-Zadeh
- Biologically Inspired Sensors and Actuators (BioSA), Faculty of Science, Dept. of Biology, York University, Toronto, Canada
- Dept. of Elecrical Engineering and Computer Science, Lassonde School of Engineering, York University, Toronto, Canada
| |
Collapse
|
12
|
Kugler P, Fröhlich D, Wendisch VF. Development of a Biosensor for Crotonobetaine-CoA Ligase Screening Based on the Elucidation of Escherichia coli Carnitine Metabolism. ACS Synth Biol 2020; 9:2460-2471. [PMID: 32794733 DOI: 10.1021/acssynbio.0c00234] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
l-Carnitine is essential in the intermediary metabolism of eukaryotes and is involved in the β-oxidation of medium- and long-chain fatty acids; thus, it has applications for medicinal purposes and as a dietary supplement. In addition, l-carnitine plays roles in bacterial physiology and metabolism, which have been exploited by the industry to develop biotechnological carnitine production processes. Here, on the basis of studies of l-carnitine metabolism in Escherichia coli and its activation by the transcriptional activator CaiF, a biosensor was developed. It expresses a fluorescent reporter gene that responds in a dose-dependent manner to crotonobetainyl-CoA, which is an intermediate of l-carnitine metabolism in E. coli and is proposed to be a coactivator of CaiF. Moreover, a dual-input biosensor for l-carnitine and crotonobetaine was developed. As an application of the biosensor, potential homologues of the betaine:CoA ligase CaiC from Citrobacter freundii, Proteus mirabilis, and Arcobacter marinus were screened and shown to be functionally active CaiC variants. These variants and the developed biosensor may be valuable for improving l-carnitine production processes.
Collapse
Affiliation(s)
- Pierre Kugler
- Genetics of Prokaryotes, Faculty of Biology & CeBiTec, Bielefeld University, 33615 Bielefeld, Germany
| | - Deborah Fröhlich
- Genetics of Prokaryotes, Faculty of Biology & CeBiTec, Bielefeld University, 33615 Bielefeld, Germany
| | - Volker F. Wendisch
- Genetics of Prokaryotes, Faculty of Biology & CeBiTec, Bielefeld University, 33615 Bielefeld, Germany
| |
Collapse
|
13
|
A New Calibration Circuit Design to Reduce Drift Effect of RuO 2 Urea Biosensors. SENSORS 2019; 19:s19204558. [PMID: 31635177 PMCID: PMC6832896 DOI: 10.3390/s19204558] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Revised: 10/11/2019] [Accepted: 10/18/2019] [Indexed: 12/20/2022]
Abstract
The goal of this study was to reduce the drift effect of RuO2 urea biosensors. A new calibration circuit (NCC) based on the voltage regulation technique with the advantage of having a simple structure was presented. To keep its simplicity, the proposed NCC was composed of a non-inverting amplifier and a voltage calibrating circuit. A ruthenium oxide (RuO2) urea biosensor was fabricated to test the calibrating characteristics of the drift rate of the proposed NCC. The experiment performed in this study was divided into two main stages. For the first stage, a sound RuO2 urea biosensor testing environment was set-up. The RuO2 urea sensing film was immersed in the urea solution for 12 h and the response voltage was measured using the voltage-time (V-T) measurement system and the proposed NCC. The results of the first stage showed that the RuO2 urea biosensor has an average sensitivity of 1.860 mV/(mg/dL) and has a linearity of 0.999 which means that the RuO2 urea biosensor had been well fabricated. The second stage of the experiment verified the proposed NCC's functions, and the results indicated that the proposed NCC reduced the drift rate of RuO2 urea biosensor to 0.02 mV/hr (98.77% reduction).
Collapse
|