1
|
Zhan K, Chen L, Li S, Yu Q, Zhao Z, Li J, Xing Y, Ren H, Wang N, Zhang G. A novel metal-organic framework based electrochemical immunosensor for the rapid detection of Salmonella typhimurium detection in milk. Food Chem 2024; 444:138672. [PMID: 38330614 DOI: 10.1016/j.foodchem.2024.138672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 01/15/2024] [Accepted: 02/02/2024] [Indexed: 02/10/2024]
Abstract
Salmonella is one of the most prevalent pathogens causing foodborne diseases. In this study, a novel electrochemical immunosensor was designed for the rapid and accurate detection of Salmonella typhimurium (S. typhimurium) in milk. Platinum nanoparticles and Co/Zn-metal-organic framework @carboxylic multiwalled carbon nanotubes in the immunosensor acted synergistically to enhance the sensing sensitivity and stability. The materials and sensors were characterised using X-ray diffractometry, scanning electron microscopy, Fourier-transform infrared spectroscopy, differential pulse voltammetry, cyclic voltammetry, and other techniques. The optimised immunosensor showed a linear response for S. typhimurium concentrations in the range from 1.3 × 102 to 1.3 × 108 CFU mL-1, with a detection limit of 9.4 × 101 CFU mL-1. The assay also demonstrates good specificity, reproducibility, stability, and practical application potential, and the method can be extended to other foodborne pathogens.
Collapse
Affiliation(s)
- Ke Zhan
- College of Food Science and Technology, Henan Agricultural University, Zhengzhou 450002, Henan, China; College of Veterinary Medicine International Joint Research Center for Animal Immunology, Zhengzhou 450046, Henan, China; Longhu Laboratory of Advanced Immunology, Zhengzhou 450046, China; Key Laboratory of Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, 450002 Henan, China; Key Laboratory of Nutrition and Healthy Food of Zhengzhou, Zhengzhou 450002, Henan, China
| | - Linlin Chen
- College of Food Science and Technology, Henan Agricultural University, Zhengzhou 450002, Henan, China; College of Veterinary Medicine International Joint Research Center for Animal Immunology, Zhengzhou 450046, Henan, China; Longhu Laboratory of Advanced Immunology, Zhengzhou 450046, China; Key Laboratory of Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, 450002 Henan, China; Key Laboratory of Nutrition and Healthy Food of Zhengzhou, Zhengzhou 450002, Henan, China
| | - Shanshan Li
- College of Veterinary Medicine, Henan Agricultural University, Zhengzhou 450002, Henan, China; College of Veterinary Medicine International Joint Research Center for Animal Immunology, Zhengzhou 450046, Henan, China; Longhu Laboratory of Advanced Immunology, Zhengzhou 450046, China; Key Laboratory of Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, 450002 Henan, China; Key Laboratory of Nutrition and Healthy Food of Zhengzhou, Zhengzhou 450002, Henan, China
| | - Qiuying Yu
- College of Food Science and Technology, Henan Agricultural University, Zhengzhou 450002, Henan, China; College of Veterinary Medicine International Joint Research Center for Animal Immunology, Zhengzhou 450046, Henan, China; Longhu Laboratory of Advanced Immunology, Zhengzhou 450046, China; Key Laboratory of Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, 450002 Henan, China; Key Laboratory of Nutrition and Healthy Food of Zhengzhou, Zhengzhou 450002, Henan, China
| | - Zheng Zhao
- College of Food Science and Technology, Henan Agricultural University, Zhengzhou 450002, Henan, China; College of Veterinary Medicine International Joint Research Center for Animal Immunology, Zhengzhou 450046, Henan, China; Longhu Laboratory of Advanced Immunology, Zhengzhou 450046, China; Key Laboratory of Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, 450002 Henan, China; Key Laboratory of Nutrition and Healthy Food of Zhengzhou, Zhengzhou 450002, Henan, China
| | - Junwei Li
- College of Food Science and Technology, Henan Agricultural University, Zhengzhou 450002, Henan, China; College of Veterinary Medicine International Joint Research Center for Animal Immunology, Zhengzhou 450046, Henan, China; Longhu Laboratory of Advanced Immunology, Zhengzhou 450046, China; Key Laboratory of Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, 450002 Henan, China; Key Laboratory of Nutrition and Healthy Food of Zhengzhou, Zhengzhou 450002, Henan, China
| | - Yunrui Xing
- Key Laboratory of Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, 450002 Henan, China
| | - Hongtao Ren
- College of Food Science and Technology, Henan Agricultural University, Zhengzhou 450002, Henan, China; College of Veterinary Medicine International Joint Research Center for Animal Immunology, Zhengzhou 450046, Henan, China; Longhu Laboratory of Advanced Immunology, Zhengzhou 450046, China; Key Laboratory of Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, 450002 Henan, China; Key Laboratory of Nutrition and Healthy Food of Zhengzhou, Zhengzhou 450002, Henan, China.
| | - Na Wang
- College of Veterinary Medicine, Henan Agricultural University, Zhengzhou 450002, Henan, China; College of Veterinary Medicine International Joint Research Center for Animal Immunology, Zhengzhou 450046, Henan, China; Longhu Laboratory of Advanced Immunology, Zhengzhou 450046, China; Key Laboratory of Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, 450002 Henan, China; Key Laboratory of Nutrition and Healthy Food of Zhengzhou, Zhengzhou 450002, Henan, China.
| | - Gaiping Zhang
- College of Veterinary Medicine International Joint Research Center for Animal Immunology, Zhengzhou 450046, Henan, China; Longhu Laboratory of Advanced Immunology, Zhengzhou 450046, China; School of Advanced Agriculture Sciences, Peking University, 100871 Beijing, China; Key Laboratory of Animal Immunology of the Ministry of Agriculture, Henan Academy of Agricultural Sciences, 450002 Henan, China
| |
Collapse
|
2
|
Du Y, Guo M, Chen Y, Mo X, Cao J, Hu F. Ultrasensitive cortisol electrochemical immunosensor amplifying by Au single-atom nanozymes and HRP enzymes. Anal Chim Acta 2024; 1303:342462. [PMID: 38609277 DOI: 10.1016/j.aca.2024.342462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 03/06/2024] [Accepted: 03/07/2024] [Indexed: 04/14/2024]
Abstract
Cortisol, a corticosteroid hormone as a primary stress hormone response to internal and external stress, has been regarded as a gold standard reliable biomarker to evaluate human mental stress. The double enzymes strategy, using nanozyme and enzyme amplifying the electrochemical signal, has been widely used to improve the performance of electrochemical biosensors. An ultra-sensitive electrochemical cortisol sensor based on Au single-atom nanozymes had been fabricated through HRP labeled anti-cortisol antibody binding with Au by Au-S bond. Based on the high catalytic activity of Au single-atom nanozymes and the high selectivity of HRP-labeled anti-cortisol antibodies, the cortisol electrochemical sensor-based Au single-atom nanozymes had an excellent response to cortisol, such as high electrochemical activity, high sensitivity, high selectivity, and wide linear range (0.15-300 ng mL-1) and low detection (0.48 pg mL-1) through the four-parameter logistic model with 95% confidence. The electrochemical cortisol sensor was used to determine the cortisol concentration of human saliva at different times.
Collapse
Affiliation(s)
- Yongling Du
- College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, Gansu, 730000, China.
| | - Min Guo
- School of Pharmacy, Lanzhou University, State Key Laboratory of Applied Organic Chemistry, Codonopsis Radix Industrial Technology Engineering Research Center, Gansu Province, Lanzhou, Gansu, 730000, China
| | - Yan Chen
- School of Pharmacy, Lanzhou University, State Key Laboratory of Applied Organic Chemistry, Codonopsis Radix Industrial Technology Engineering Research Center, Gansu Province, Lanzhou, Gansu, 730000, China
| | - Xiaohui Mo
- School of Pharmacy, Lanzhou University, State Key Laboratory of Applied Organic Chemistry, Codonopsis Radix Industrial Technology Engineering Research Center, Gansu Province, Lanzhou, Gansu, 730000, China
| | - Junlei Cao
- College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, Gansu, 730000, China
| | - Fangdi Hu
- School of Pharmacy, Lanzhou University, State Key Laboratory of Applied Organic Chemistry, Codonopsis Radix Industrial Technology Engineering Research Center, Gansu Province, Lanzhou, Gansu, 730000, China.
| |
Collapse
|
3
|
Chen D, He Y, Wang Y, Zhang Z, Pei Y, Lei Y, Hu J, Xiang S, Jaffrezic-Renault N, Guo Z. An immune sandwich electrochemical biosensor based on triple-modified zirconium derivatives for detection of CD146 in serum. Colloids Surf B Biointerfaces 2024; 239:113902. [PMID: 38599037 DOI: 10.1016/j.colsurfb.2024.113902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 03/21/2024] [Accepted: 04/05/2024] [Indexed: 04/12/2024]
Abstract
CD146, also known as melanoma cell adhesion molecule (MCAM), is overexpressed in various cancer patients, making it a valuable predictor for early diagnosis. In this work, an immune sandwich electrochemical biosensor is proposed for sensitive and non-invasive quantitative detection of CD146 in serum. Zirconium-based MOF (UIO-66) was modified by simultaneous copper atom doping, in situ growth carbon-based support and physical embedding of platinum nanoparticles (PtNPs). Triple-modified Cu-UIO-66@SWCNT/PtNPs nanocomposites with high stability and excellent electrochemical properties, serve as surface modification materials for glassy carbon electrodes. Anti-CD146 antibody (Ab1) was grafted onto the electrode surface via Pt-S bond. Meanwhile, the secondary antibody (Ab2) was conjugated with silver nanoparticles (AgNPs) to cooperate for CD146 capture and achieve secondary electrical signal amplification. Under optimal conditions, square wave voltammetry was employed to determine CD146 in the concentration range of 10-9-10-4 mg/mL and a limit of detection of 12 fg/mL was obtained. Finally, it was successfully applied to the analysis of CD146 in lung and liver cancer patients' serum samples.
Collapse
Affiliation(s)
- Die Chen
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Medicine, School of Public Health, Faculty of Medicine, Wuhan University of Science and Technology, Wuhan 430065, PR China
| | - Yutao He
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Medicine, School of Public Health, Faculty of Medicine, Wuhan University of Science and Technology, Wuhan 430065, PR China
| | - Ya Wang
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Medicine, School of Public Health, Faculty of Medicine, Wuhan University of Science and Technology, Wuhan 430065, PR China
| | - Ziyi Zhang
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Medicine, School of Public Health, Faculty of Medicine, Wuhan University of Science and Technology, Wuhan 430065, PR China
| | - Yifei Pei
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Medicine, School of Public Health, Faculty of Medicine, Wuhan University of Science and Technology, Wuhan 430065, PR China
| | - Yumeng Lei
- Department of Medical Ultrasound, China Resources & Wisco General Hospital, Wuhan University of Science and Technology, Wuhan 430080, PR China
| | - Junrui Hu
- Department of Pharmacy, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, PR China
| | - Shiqiang Xiang
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Medicine, School of Public Health, Faculty of Medicine, Wuhan University of Science and Technology, Wuhan 430065, PR China.
| | - Nicole Jaffrezic-Renault
- University of Lyon, Institute of Analytical Sciences, UMR-CNRS 5280, 5, La Doua Street, Villeurbanne 69100, France.
| | - Zhenzhong Guo
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Medicine, School of Public Health, Faculty of Medicine, Wuhan University of Science and Technology, Wuhan 430065, PR China.
| |
Collapse
|
4
|
Zhou H, Abudureheman T, Zheng W, Yang L, Zhu J, Liang A, Duan C, Chen K. CAR-Aptamers Enable Traceless Enrichment and Monitoring of CAR-Positive Cells and Overcome Tumor Immune Escape. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2305566. [PMID: 38148412 PMCID: PMC10933668 DOI: 10.1002/advs.202305566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 12/06/2023] [Indexed: 12/28/2023]
Abstract
Chimeric antigen receptor (CAR)-positive cell therapy, specifically with anti-CD19 CAR-T (CAR19-T) cells, achieves a high complete response during tumor treatment for hematological malignancies. Large-scale production and application of CAR-T therapy can be achieved by developing efficient and low-cost enrichment methods for CAR-T cells, expansion monitoring in vivo, and overcoming tumor escape. Here, novel CAR-specific binding aptamers (CAR-ap) to traceless sort CAR-positive cells and obtain a high positive rate of CAR19-T cells is identified. Additionally, CAR-ap-enriched CAR19-T cells exhibit similar antitumor capacity as CAR-ab (anti-CAR antibody)-enriched CAR-T cells. Moreover, CAR-ap accurately monitors the expansion of CAR19-T cells in vivo and predicts the prognosis of CAR-T treatment. Essentially, a novel class of stable CAR-ap-based bispecific circular aptamers (CAR-bc-ap) is constructed by linking CAR-ap with a tumor surface antigen (TSA): protein tyrosine kinase 7 (PTK7) binding aptamer Sgc8. These CAR-bc-aps significantly enhance antitumor cytotoxicity with a loss of target antigens by retargeting CAR-T cells to the tumor in vitro and in vivo. Overall, novel CAR-aptamers are screened for traceless enrichment, monitoring of CAR-positive cells, and overcoming tumor cell immune escape. This provides a low-cost and high-throughput approach for CAR-positive cell-based immunotherapy.
Collapse
Affiliation(s)
- Hang Zhou
- Key Laboratory of Pediatric Hematology and Oncology Ministry of Health, Pediatric Translational Medicine Institute, Shanghai Children's Medical CenterShanghai Jiao Tong University School of MedicineShanghai200127China
| | - Tuersunayi Abudureheman
- Key Laboratory of Pediatric Hematology and Oncology Ministry of Health, Pediatric Translational Medicine Institute, Shanghai Children's Medical CenterShanghai Jiao Tong University School of MedicineShanghai200127China
- Fujian Branch of Shanghai Children's Medical Center, affiliated with Shanghai Jiaotong UniversitySchool of Medicine and Fujian Children's HospitalFuzhouFujian350005China
| | - Wei‐Wei Zheng
- Key Laboratory of Pediatric Hematology and Oncology Ministry of Health, Pediatric Translational Medicine Institute, Shanghai Children's Medical CenterShanghai Jiao Tong University School of MedicineShanghai200127China
| | - Li‐Ting Yang
- Key Laboratory of Pediatric Hematology and Oncology Ministry of Health, Pediatric Translational Medicine Institute, Shanghai Children's Medical CenterShanghai Jiao Tong University School of MedicineShanghai200127China
| | - Jian‐Min Zhu
- Key Laboratory of Pediatric Hematology and Oncology Ministry of Health, Pediatric Translational Medicine Institute, Shanghai Children's Medical CenterShanghai Jiao Tong University School of MedicineShanghai200127China
| | - Ai‐Bin Liang
- Department of Hematology, Tongji HospitalTongji University School of MedicineShanghai200065China
| | - Cai‐Wen Duan
- Key Laboratory of Pediatric Hematology and Oncology Ministry of Health, Pediatric Translational Medicine Institute, Shanghai Children's Medical CenterShanghai Jiao Tong University School of MedicineShanghai200127China
- Fujian Branch of Shanghai Children's Medical Center, affiliated with Shanghai Jiaotong UniversitySchool of Medicine and Fujian Children's HospitalFuzhouFujian350005China
- Key Laboratory of Technical Evaluation of Fertility Regulation for Non‐human Primate, National Health CommissionFujian Maternity and Child Health HospitalFuzhouFujian350122China
| | - Kaiming Chen
- Key Laboratory of Pediatric Hematology and Oncology Ministry of Health, Pediatric Translational Medicine Institute, Shanghai Children's Medical CenterShanghai Jiao Tong University School of MedicineShanghai200127China
- Fujian Branch of Shanghai Children's Medical Center, affiliated with Shanghai Jiaotong UniversitySchool of Medicine and Fujian Children's HospitalFuzhouFujian350005China
| |
Collapse
|
5
|
Geng L, Wang H, Liu M, Huang J, Wang G, Guo Z, Guo Y, Sun X. Research progress on preparation methods and sensing applications of molecularly imprinted polymer-aptamer dual recognition elements. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 912:168832. [PMID: 38036131 DOI: 10.1016/j.scitotenv.2023.168832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 11/21/2023] [Accepted: 11/22/2023] [Indexed: 12/02/2023]
Abstract
The aptamer (Apt) and the molecularly imprinted polymer (MIP), as effective substitutes for antibodies, have received widespread attention from researchers because of their creation. However, the low stability of Apt in harsh detection environment and the poor specificity of MIP have hindered their development. Therefore, some researchers have attempted to combine MIP with Apt to explore whether the effect of "1 + 1 > 2" can be achieved. Since its first report in 2013, MIP-Apt dual recognition elements have become a highly focused research direction in the fields of biology and chemistry. MIP-Apt dual recognition elements not only possess the high specificity of Apt and the high stability of MIP in harsh detection environment, but also have high sensitivity and affinity. They have been successfully applied in medical diagnosis, food safety, and environmental monitoring fields. This article provides a systematic overview of three preparation methods for MIP-Apt dual recognition elements and their application in eight different types of sensors. It also provides effective insights into the problems and development directions faced by MIP-Apt dual recognition elements.
Collapse
Affiliation(s)
- Lingjun Geng
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Haifang Wang
- Dongzhimen Hospital, Beijing University of Chinese Medicine, Beijing 100700, China
| | - Mengyue Liu
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Jingcheng Huang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Guangxian Wang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Zhen Guo
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Yemin Guo
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China.
| | - Xia Sun
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| |
Collapse
|
6
|
Zhang P, Zhu B, Du P, Travas-Sejdic J. Electrochemical and Electrical Biosensors for Wearable and Implantable Electronics Based on Conducting Polymers and Carbon-Based Materials. Chem Rev 2024; 124:722-767. [PMID: 38157565 DOI: 10.1021/acs.chemrev.3c00392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2024]
Abstract
Bioelectronic devices are designed to translate biological information into electrical signals and vice versa, thereby bridging the gap between the living biological world and electronic systems. Among different types of bioelectronics devices, wearable and implantable biosensors are particularly important as they offer access to the physiological and biochemical activities of tissues and organs, which is significant in diagnosing and researching various medical conditions. Organic conducting and semiconducting materials, including conducting polymers (CPs) and graphene and carbon nanotubes (CNTs), are some of the most promising candidates for wearable and implantable biosensors. Their unique electrical, electrochemical, and mechanical properties bring new possibilities to bioelectronics that could not be realized by utilizing metals- or silicon-based analogues. The use of organic- and carbon-based conductors in the development of wearable and implantable biosensors has emerged as a rapidly growing research field, with remarkable progress being made in recent years. The use of such materials addresses the issue of mismatched properties between biological tissues and electronic devices, as well as the improvement in the accuracy and fidelity of the transferred information. In this review, we highlight the most recent advances in this field and provide insights into organic and carbon-based (semi)conducting materials' properties and relate these to their applications in wearable/implantable biosensors. We also provide a perspective on the promising potential and exciting future developments of wearable/implantable biosensors.
Collapse
Affiliation(s)
- Peikai Zhang
- Centre for Innovative Materials for Health, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- MacDiarmid Institute for Advanced Materials and Nanotechnology, Victoria University of Wellington, Wellington 6012, New Zealand
- Auckland Bioengineering Institute, The University of Auckland, Auckland 1010, New Zealand
| | - Bicheng Zhu
- Centre for Innovative Materials for Health, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- MacDiarmid Institute for Advanced Materials and Nanotechnology, Victoria University of Wellington, Wellington 6012, New Zealand
| | - Peng Du
- Auckland Bioengineering Institute, The University of Auckland, Auckland 1010, New Zealand
| | - Jadranka Travas-Sejdic
- Centre for Innovative Materials for Health, School of Chemical Sciences, The University of Auckland, Auckland 1010, New Zealand
- MacDiarmid Institute for Advanced Materials and Nanotechnology, Victoria University of Wellington, Wellington 6012, New Zealand
| |
Collapse
|
7
|
Weber CJ, Clay OM, Lycan RE, Anderson GK, Simoska O. Advances in electrochemical biosensor design for the detection of the stress biomarker cortisol. Anal Bioanal Chem 2024; 416:87-106. [PMID: 37989847 DOI: 10.1007/s00216-023-05047-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/30/2023] [Accepted: 11/08/2023] [Indexed: 11/23/2023]
Abstract
The monitoring of stress levels in humans has become increasingly relevant, given the recent incline of stress-related mental health disorders, lifestyle impacts, and chronic physiological diseases. Long-term exposure to stress can induce anxiety and depression, heart disease, and risky behaviors, such as drug and alcohol abuse. Biomarker molecules can be quantified in biological fluids to study human stress. Cortisol, specifically, is a hormone biomarker produced in the adrenal glands with biofluid concentrations that directly correlate to stress levels in humans. The rapid, real-time detection of cortisol is necessary for stress management and predicting the onset of psychological and physical ailments. Current methods, including mass spectrometry and immunoassays, are effective for sensitive cortisol quantification. However, these techniques provide only single measurements which pose challenges in the continuous monitoring of stress levels. Additionally, these analytical methods often require trained personnel to operate expensive instrumentation. Alternatively, low-cost electrochemical biosensors enable the real-time detection and continuous monitoring of cortisol levels while also providing adequate analytical figures of merit (e.g., sensitivity, selectivity, sensor response times, detection limits, and reproducibility) in a simple design platform. This review discusses the recent developments in electrochemical biosensor design for the detection of cortisol in human biofluids. Special emphasis is given to biosensor recognition elements, including antibodies, molecularly imprinted polymers (MIPs), and aptamers, as critical components of electrochemical biosensors for cortisol detection. Furthermore, the advantages and limiting factors of various electrochemical techniques and sensing in complex biofluid matrices are overviewed. Remarks on the current challenges and future perspectives regarding electrochemical biosensors for stress monitoring are provided, including matrix effects (pH dependence and biological interferences), wearability, and large-scale production.
Collapse
Affiliation(s)
- Courtney J Weber
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC, 29208, USA
| | - Olivia M Clay
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC, 29208, USA
| | - Reese E Lycan
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC, 29208, USA
| | - Gracie K Anderson
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC, 29208, USA
| | - Olja Simoska
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC, 29208, USA.
| |
Collapse
|
8
|
Mohammadi F, Zahraee H, Izadpanah Kazemi M, Habibi ZS, Taghdisi SM, Abnous K, Khoshbin Z, Chen CH. Recent advances in aptamer-based platforms for cortisol hormone monitoring. Talanta 2024; 266:125010. [PMID: 37541008 DOI: 10.1016/j.talanta.2023.125010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 07/19/2023] [Accepted: 07/28/2023] [Indexed: 08/06/2023]
Abstract
The stressful conditions of today-life make it urgent the timely prevention and treatment of many physiological and psychological disorders related to stress. According to the significant progress made in the near future, rapid, accurate, and on-spot measurement of cortisol hormone as a dominant stress biomarker using miniaturized digital devices is not far from expected. With a special potency in the fields of diagnosis and healthcare monitoring, aptamer-mediated biosensors (aptasensors) are promising for the quantitative monitoring of cortisol levels in the different matrices (sweat, saliva, urine, cerebrospinal fluid, blood serum, etc.). Accordingly, this in-depth study reviews the superior achievements in the aptasensing strategies to detect cortisol hormone with the synergism of diverse two/three dimensional nanostructured materials, enzymatic amplification components, and antibody motifs. The represented discussions offer a universal perspective to achieve lab-on-chip aptasensing arrays as future user-friendly skin-patchable electronic gadgets for on-site and real-time quantification of cortisol levels.
Collapse
Affiliation(s)
- Fatemeh Mohammadi
- Department of Biology, Faculty of Science, Ferdowsi University of Mashhad, Mashhad, Iran; Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Hamed Zahraee
- Department of Biology, Faculty of Science, Ferdowsi University of Mashhad, Mashhad, Iran; Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
| | | | - Zahra Sadat Habibi
- Department of Environmental Engineering, Faculty of Natural Resources and Environment, University of Birjand, Birjand, Iran
| | - Seyed Mohammad Taghdisi
- Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Pharmaceutical Biotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Khalil Abnous
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Medicinal Chemistry, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Zahra Khoshbin
- Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Medicinal Chemistry, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran.
| | - Chih-Hsin Chen
- Department of Chemistry, Tamkang University, New Taipei City, 25137, Taiwan.
| |
Collapse
|
9
|
Karuppaiah G, Lee MH, Bhansali S, Manickam P. Electrochemical sensors for cortisol detection: Principles, designs, fabrication, and characterisation. Biosens Bioelectron 2023; 239:115600. [PMID: 37611448 DOI: 10.1016/j.bios.2023.115600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Revised: 08/09/2023] [Accepted: 08/12/2023] [Indexed: 08/25/2023]
Abstract
Psychological stress is a major factor contributing to health discrepancies among individuals. Sustained exposure to stress triggers signalling pathways in the brain, which leading to the release of stress hormones in the body. Cortisol, a steroid hormone, is a significant biomarker for stress management due to its responsibility in the body's reply to stress. The release of cortisol in bloodstream prepares the body for a "fight or flight" response by increasing heart rate, blood pressure, metabolism, and suppressing the immune system. Detecting cortisol in biological samples is crucial for understanding its role in stress and personalized healthcare. Traditional techniques for cortisol detection have limitations, prompting researchers to explore alternative strategies. Electrochemical sensing has emerged as a reliable method for point-of-care (POC) cortisol detection. This review focuses on the progress made in electrochemical sensors for cortisol detection, covering their design, principle, and electroanalytical methodologies. The analytical performance of these sensors is also analysed and summarized. Despite significant advancements, the development of electrochemical cortisol sensors faces challenges such as biofouling, sample preparation, sensitivity, flexibility, stability, and recognition layer performance. Therefore, the need to develop more sensitive electrodes and materials is emphasized. Finally, we discussed the potential strategies for electrode design and provides examples of sensing approaches. Moreover, the encounters of translating research into real world applications are addressed.
Collapse
Affiliation(s)
- Gopi Karuppaiah
- Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute (CECRI), Karaikudi, 630 003, Tamil Nadu, India; School of Integrative Engineering, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul, 06974, Republic of Korea
| | - Min-Ho Lee
- School of Integrative Engineering, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul, 06974, Republic of Korea
| | - Shekhar Bhansali
- Department of Electrical and Computer Engineering, Florida International University, Miami, FL, 33174, USA.
| | - Pandiaraj Manickam
- Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute (CECRI), Karaikudi, 630 003, Tamil Nadu, India; Academy of Scientific and Innovative Research, Ghaziabad, 201 002, Uttar Pradesh, India.
| |
Collapse
|
10
|
Wang Y, Murakami H, Kasama T, Mitsuzawa S, Shinkawa S, Miyake R, Takai M. An automatic immuno-microfluidic system integrating electrospun polystyrene microfibrous reactors for rapid detection of salivary cortisol. iScience 2023; 26:107820. [PMID: 37752956 PMCID: PMC10518708 DOI: 10.1016/j.isci.2023.107820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 06/16/2023] [Accepted: 08/31/2023] [Indexed: 09/28/2023] Open
Abstract
Conventional competitive enzyme-linked immunosorbent assay (ELISA) to measure the cortisol level in body fluid consumes a large amount of time, owing to complicated operations involved and requirement for precise control of reagent addition. We developed an automatic microfluidic system to detect salivary cortisol rapidly, and an electrospun polystyrene (PS) microfiber-based reactor providing considerable binding sites for antibody immobilization, thus resolving the time limitations of competitive ELISA. Cortisol sample, horseradish peroxidase (HRP)-conjugated cortisol, and 3,3',5,5'-tetramethylbenzidine (TMB) substrate were delivered to the PS reactor from containers in sequence by pumps automatically. The color variation due to oxidized TMB complex reflects the cortisol concentration level measured using an RGB phototransistor. In addition, the entire procedure from sample introduction to obtaining the photocurrent took only 15 min. This system can be implemented to quantify cortisol from 0.37 ng/mL to 30 ng/mL, and the limit of detection was estimated at 0.37 ng/mL.
Collapse
Affiliation(s)
- Yecan Wang
- Graduate School of Bioengineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo City, Tokyo 113-8654, Japan
| | - Hiroshi Murakami
- Graduate School of Bioengineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo City, Tokyo 113-8654, Japan
| | - Toshihiro Kasama
- Graduate School of Bioengineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo City, Tokyo 113-8654, Japan
| | | | - Satoru Shinkawa
- Honda Motor Co., Ltd, 8-1 Honcho, Wako, Saitama 351-0114, Japan
| | - Ryo Miyake
- Graduate School of Bioengineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo City, Tokyo 113-8654, Japan
| | - Madoka Takai
- Graduate School of Bioengineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo City, Tokyo 113-8654, Japan
| |
Collapse
|
11
|
Zhao G. Multi-Residue Detection of Eight Glucocorticoids by Nano-Au/Fluticasone Propionate Electrochemical Immunosensor. Molecules 2023; 28:6619. [PMID: 37764395 PMCID: PMC10534488 DOI: 10.3390/molecules28186619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 09/08/2023] [Accepted: 09/08/2023] [Indexed: 09/29/2023] Open
Abstract
Based on an indirect competitive method, a novel nano-Au/fluticasone propionate electrochemical immunosensor was successfully fabricated by combining the nanoscale effect, superior conductivity of nano-Au, stable Au-S chemical bond as well as strong interaction between glucocorticoid and the receptor, which was used to simultaneously detect eight kinds of glucocorticoids. The modified immunosensors' electrochemical properties were explored by means of a cyclic voltammetry (CV) method and electrochemical impedance spectroscopy (EIS) measurements. Two factors (glucocorticoid receptor concentration, incubation time) were studied in order to obtain the optimal results. The immunosensor presents attractive electrochemical performance with a wide linear range (between 0.1 and 1500 ng⋅mL-1) and low detection limit (between 0.057 and 0.357 ng⋅mL-1), realizing the rapid multi-residue detection of a large class of glucocorticoids. Two glucocorticoids (hydrocortisone, triamcinolone) were detected in actual skincare samples, which obtained satisfactory detection results.
Collapse
Affiliation(s)
- Guozheng Zhao
- Key Laboratory of Magnetic Molecules & Magnetic Information Materials (Ministry of Education), School of Chemistry and Material Science, College of Food Science, Shanxi Normal University, Taiyuan 030031, China;
- Modern College of Humanities and Sciences of Shanxi Normal University, Linfen 041000, China
| |
Collapse
|
12
|
Song H, Khan M, Yu L, Wang Y, Lin JM, Hu Q. Construction of Liquid Crystal-Based Sensors Using Enzyme-Linked Dual-Functional Nucleic Acid on Magnetic Beads. Anal Chem 2023; 95:13385-13390. [PMID: 37622311 DOI: 10.1021/acs.analchem.3c03163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/26/2023]
Abstract
The development of liquid crystal (LC)-based sensors with superior performances such as high portability, excellent stability, great convenience, and remarkable sensitivity is highly demanded. This work proposes a new strategy for constructing the LC-based sensor using enzyme-linked dual-functional nucleic acid (d-FNA) on magnetic beads (MBs). The detection of kanamycin (KA) is demonstrated as a model. Acetylcholinesterase (AChE) is assembled onto the KA aptamer-modified MBs with a d-FNA strand that consists of an AChE aptamer and the complementary sequence of a KA aptamer. As the specific recognition of KA by its aptamer triggers the release of AChE from the MBs, the myristoylcholine (Myr) solution after incubation with the MBs causes the black image of the LCs due to the formation of the Myr monolayer at the aqueous/LC interface. Otherwise, in the absence of KA, AChE is still decorated on the MBs and causes the hydrolysis of Myr. Therefore, a bright image of LCs is obtained. The detection of KA is successfully achieved with a lower detection limit of 48.1 pg/mL. In addition, a thin polydimethylsiloxane (PDMS) layer-coated glass and a portable optical device are used to improve the stability and portability of the LC-based sensor to advance potential commercial applications. Furthermore, the detection of KA in milk with a portable device is demonstrated, showing the potential of the proposed enzyme-linked LC-based sensor.
Collapse
Affiliation(s)
- Haoyang Song
- Qilu University of Technology (Shandong Academy of Sciences), Shandong Analysis and Test Center, Jinan 250014, China
- School of Pharmaceutical Sciences, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China
| | - Mashooq Khan
- Qilu University of Technology (Shandong Academy of Sciences), Shandong Analysis and Test Center, Jinan 250014, China
- School of Pharmaceutical Sciences, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China
| | - Li Yu
- Key Laboratory of Colloid and Interface Chemistry, Shandong University, Ministry of Education, Jinan 250100, China
| | - Yunshan Wang
- Department of Clinical Laboratory, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan 250021, China
| | - Jin-Ming Lin
- Beijing Key Laboratory of Microanalytical Methods and Instrumentation, MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Department of Chemistry, Tsinghua University, Beijing 100084, China
| | - Qiongzheng Hu
- Qilu University of Technology (Shandong Academy of Sciences), Shandong Analysis and Test Center, Jinan 250014, China
- School of Pharmaceutical Sciences, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China
| |
Collapse
|
13
|
Shang Z, Su T, Jin D, Xu Q, Hu X, Shu Y. An integrated and flexible PDMS/Au film-based electrochemical immunosensor via Fe–Co MOF as a signal amplifier for alpha fetoprotein detection. Biosens Bioelectron 2023; 230:115245. [PMID: 36989661 DOI: 10.1016/j.bios.2023.115245] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 03/15/2023] [Accepted: 03/20/2023] [Indexed: 03/29/2023]
Abstract
Ultrasensitive determination of tumor marker (TM) is of great significance in cancer prevention and diagnosis. Traditional TM detection methods involve large instrumentation and professional manipulation, which complicate the assay procedures and increase the cost of investment. To resolve these problems, an integrated electrochemical immunosensor based on the flexible polydimethylsiloxane/gold (PDMS/Au) film with Fe-Co metal-organic framework (Fe-Co MOF) as a signal amplifier was fabricated for ultrasensitive determination of alpha fetoprotein (AFP). First, gold layer was deposited on the hydrophilic PDMS film to form the flexible three-electrode system, and then the thiolated aptamer for AFP was immobilized. Afterward, the aminated Fe-Co MOF possessing high peroxidase-like activity and large specific surface area was prepared by a facile solvothermal method, and subsequently the biofunctionalized MOF could effectively capture biotin antibody (Ab) to form MOF-Ab as a signal probe and amplify the electrochemical signal remarkably, thereby realizing highly sensitive detection of AFP with a wide linear range of 0.01-300 ng/mL and a low detection limit of 0.71 pg/mL. In addition, the PDMS based-immunosensor showed good accuracy for assaying of AFP in clinical serum samples. The integrated and flexible electrochemical immunosensor based on the Fe-Co MOF as a signal amplifier demonstrates great potential for application in the personalized point-of-care (POC) clinical diagnosis.
Collapse
|
14
|
Su T, Mi Z, Xia Y, Jin D, Xu Q, Hu X, Shu Y. A wearable sweat electrochemical aptasensor based on the Ni-Co MOF nanosheet-decorated CNTs/PU film for monitoring of stress biomarker. Talanta 2023; 260:124620. [PMID: 37148688 DOI: 10.1016/j.talanta.2023.124620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 04/15/2023] [Accepted: 04/30/2023] [Indexed: 05/08/2023]
Abstract
Monitoring cortisol, a hormone released by the adrenal cortex in response to stress, is essential to evaluate the endocrine response to stress stimuli. While the current cortisol sensing methods require large laboratory settings, complex assay, and professional personnel. Herein, a novel flexible and wearable electrochemical aptasensor based on a Ni-Co metal-organic frameworks (MOF) nanosheet-decorated carbon nanotubes (CNTs)/polyurethane (PU) film is developed for rapid and reliable detection of cortisol in sweat. First, the CNTs/PU (CP) film was prepared by a modified wet spinning technology, and the CNTs/polyvinyl alcohol (PVA) solution was thermally deposited on the surface of CP film to form the highly flexible CNTs/PVA/CP (CCP) film with excellent conductivity. Then aminated Ni-Co MOF nanosheet prepared by a facile solvothermal method was conjugated with streptavidin and modified on the CCP film. Biofunctional MOF can effectively capture cortisol aptamer due to its excellent specific surface area. In addition, the MOF with peroxidase activity can catalytic oxidization of hydroquinone (HQ) by hydrogen peroxide (H2O2), which could amplify the peak current signal. The catalytic activity of Ni-Co MOF was substantially suppressed in the HQ/H2O2 system due to the formation of the aptamer-cortisol complex, which reduced the current signal, thereby realizing highly sensitive and selective detection of cortisol. The sensor has a linear range of 0.1-100 ng/mL and a detection limit of 0.032 ng/mL. Meanwhile, the sensor showed high accuracy for cortisol detection under mechanical deformation conditions. More importantly, the prepared MOF/CCP film based three-electrode was assembled with the polydimethylsiloxane (PDMS) substrate, and the sweat-cloth was used as the sweat collection channel to fabricate a wearable sensor patch for monitoring of cortisol in volunteers' sweat in the morning and evening. This flexible and non-invasive sweat cortisol aptasensor shows great potential for quantitative stress monitoring and management.
Collapse
Affiliation(s)
- Tong Su
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, PR China
| | - Ziyi Mi
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, PR China
| | - Youyuan Xia
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, PR China
| | - Dangqin Jin
- Department of Chemical Engineering, Yangzhou Polytechnic Institute, Yangzhou 225127, PR China
| | - Qin Xu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, PR China
| | - Xiaoya Hu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, PR China
| | - Yun Shu
- School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, PR China.
| |
Collapse
|
15
|
Fu S, Xie C, Yang Z, Jiang M, Cheng J, Zhu C, Wu K, Ye H, Xia W, Jaffrezic-Renault N, Guo Z. Electrochemical signal amplification strategy based on trace metal ion modified WS 2 for ultra-sensitive detection of miRNA-21. Talanta 2023; 260:124552. [PMID: 37087947 DOI: 10.1016/j.talanta.2023.124552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 04/07/2023] [Accepted: 04/11/2023] [Indexed: 04/25/2023]
Abstract
Previous researches have suggested the potential correlation between the development of breast cancer and the concentration of miRNA-21 in serum. Theoretically the doping of multivalent metal ions in WS2 could bring higher electron transfer capacity, but this hasn't been proven. To fill this research gap, through one-pot method we prepared seven nanocomposite structures modified with different metal ions (Co2+, Ni2+, Mn2+, Zn2+, Fe3+, Cr3+, La3+). Characterization revealed that ammonia produced by hydrothermal urea exfoliated the multilayer graphene oxide (MGO) and provided a nitrogen source for doping reduction to form a 3D flower-like structure (NrGOF) with high specific surface area. Meanwhile, the modification of WS2 by Fe3+ not only enhanced its electrochemical conductivity but also gave the material an additional peroxidase activity centre. In the composite Fe3+-WS2/NrGOF-AgNPs, NrGOF is used as a conductive loading interface for WS2, while Fe3+ served as the catalytic and electron transfer centre for secondary amplification of the electrochemical signal. The experimental results showed that the sensing platform has a low limit of detection (LOD) of 1.18 aM for miRNA-21 in the concentration range of 10-17-10-12 M and has been successfully applied to the detection of real serum samples.
Collapse
Affiliation(s)
- Sinan Fu
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Medicine, School of Public Health, Wuhan University of Science and Technology, Wuhan, 430065, PR China
| | - Chang Xie
- State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, PR China
| | - Zhiruo Yang
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Medicine, School of Public Health, Wuhan University of Science and Technology, Wuhan, 430065, PR China
| | - Mingdi Jiang
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Medicine, School of Public Health, Wuhan University of Science and Technology, Wuhan, 430065, PR China
| | - Jing Cheng
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Medicine, School of Public Health, Wuhan University of Science and Technology, Wuhan, 430065, PR China
| | - Chengliang Zhu
- Department of Clinical Laboratory, Renmin Hospital, Wuhan University, Wuhan, 430060, PR China
| | - Kailang Wu
- State Key Laboratory of Virology, College of Life Sciences, Wuhan University, Wuhan, 430062, PR China
| | - Huarong Ye
- China Resources & Wisco General Hospital, Wuhan, 430080, PR China
| | - Wei Xia
- Department of Anesthesiology, Tongji Hospital, Tongji Medical College of Huazhong University of Science & Technology, Wuhan, 430030, PR China.
| | - Nicole Jaffrezic-Renault
- University of Lyon, Institute of Analytical Sciences, UMR-CNRS 5280, 5, La Doua Street, Villeurbanne, 69100, France.
| | - Zhenzhong Guo
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Medicine, School of Public Health, Wuhan University of Science and Technology, Wuhan, 430065, PR China.
| |
Collapse
|
16
|
Kaur S, Gupta N, Malhotra BD. Recent developments in wearable & non-wearable point-of-care biosensors for cortisol detection. Expert Rev Mol Diagn 2023; 23:217-230. [PMID: 36880128 DOI: 10.1080/14737159.2023.2184260] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
Abstract
INTRODUCTION Cortisol is one of the most prominent biomarkers used for the detection of psychological stress and related disorders. It plays an important role in many physiological processes including immunomodulation and fat metabolism. Thus, monitoring of cortisol levels can be used to indicate different pathological conditions including stress disorders. There has been a gradual rise in the development of point of care (PoC) biosensors for continuous cortisol monitoring. AREAS COVERED This review discusses recent breakthroughs toward the development of PoC sensors (wearable and non wearable) for cortisol monitoring. Challenges associated with them have also been summarized. EXPERT OPINION Electrochemical PoC devices have recently emerged as a powerful tools for continuous monitoring of cortisol that can be utilized for stress management and treatment of related disorders. However, there are many challenges that should be addressed before such devices can be deployed at mass level, such as inter-individual variability, changing the device calibration with the circadian rhythm, interference from other endocrine moieties, etc. [Figure: see text].
Collapse
Affiliation(s)
- Simran Kaur
- Nanobioelectronics Lab, Department of Biotechnology, Delhi Technological University, Delhi, INDIA
| | - Niharika Gupta
- Nanobioelectronics Lab, Department of Biotechnology, Delhi Technological University, Delhi, INDIA
| | - Bansi D Malhotra
- Nanobioelectronics Lab, Department of Biotechnology, Delhi Technological University, Delhi, INDIA.,Biomedical Instrumentation Section, CSIR-National Physical Laboratory, New Delhi, India
| |
Collapse
|
17
|
Zhu Y, Yao X, Yan K, Chen Y, Zhang J. A ratiometric self-powered aptasensor for simultaneous detection of cortisol and progesterone based on spatially resolved tri-channel photofuel cell. Biosens Bioelectron 2023; 223:115020. [PMID: 36586148 DOI: 10.1016/j.bios.2022.115020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 12/14/2022] [Accepted: 12/15/2022] [Indexed: 12/24/2022]
Abstract
In this work, a self-powered sensor was proposed for simultaneous detection of two typical steroid hormones, namely cortisol (COR) and progesterone (P4). A tri-channel photofuel cell (PFC) consisting of three spatially resolved SnS2@SnO2 photoanodes and one Pt cathode was designed to generate the electricity to drive the sensing process under the control of a multiplex switch. Among three photoanodes, one served as the control, while the other two were modified with COR-binding or P4-binding aptamer to respond specifically to the COR or P4 target. The ratios of the inhibited PFC output from aptamer-immobilized photoanodes to the reference signal from the control photoanode were utilized for simultaneous detection of COR and P4. The results showed that the developed self-powered sensor exhibited broad concentration ranges toward targets, with COR concentration ranging from 1 nM to 1000 nM and P4 concentration ranging from 1 nM to 500 nM. The detection limits for COR and P4 were calculated to be 0.88 nM and 0.52 nM, respectively. Moreover, the proposed sensing platform demonstrated high selectivity, good reproducibility, and high stability. Finally, the sensor was successfully applied to the simultaneous determination of COR and P4 in a human female serum sample.
Collapse
Affiliation(s)
- Yuhan Zhu
- Hubei Key Laboratory of Purification and Application of Plant Anti-cancer Active Ingredients, College of Chemistry and Life Science, Hubei University of Education, Gaoxin 2nd Road 129, Wuhan, 430205, PR China; Key Laboratory of Material Chemistry for Energy Conversion and Storage (Ministry of Education), Hubei Key Laboratory of Bioinorganic Chemistry & Materia Medica, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Luoyu Road 1037, Wuhan, 430074, PR China
| | - Xiaoling Yao
- Key Laboratory of Material Chemistry for Energy Conversion and Storage (Ministry of Education), Hubei Key Laboratory of Bioinorganic Chemistry & Materia Medica, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Luoyu Road 1037, Wuhan, 430074, PR China
| | - Kai Yan
- Key Laboratory of Material Chemistry for Energy Conversion and Storage (Ministry of Education), Hubei Key Laboratory of Bioinorganic Chemistry & Materia Medica, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Luoyu Road 1037, Wuhan, 430074, PR China
| | - Yingxu Chen
- Hubei Key Laboratory of Purification and Application of Plant Anti-cancer Active Ingredients, College of Chemistry and Life Science, Hubei University of Education, Gaoxin 2nd Road 129, Wuhan, 430205, PR China
| | - Jingdong Zhang
- Key Laboratory of Material Chemistry for Energy Conversion and Storage (Ministry of Education), Hubei Key Laboratory of Bioinorganic Chemistry & Materia Medica, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Luoyu Road 1037, Wuhan, 430074, PR China.
| |
Collapse
|
18
|
Tamiya E, Osaki S, Tsuchihashi T, Ushijima H, Tsukinoki K. Point-of-Care Diagnostic Biosensors to Monitor Anti-SARS-CoV-2 Neutralizing IgG/sIgA Antibodies and Antioxidant Activity in Saliva. BIOSENSORS 2023; 13:167. [PMID: 36831933 PMCID: PMC9953869 DOI: 10.3390/bios13020167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Revised: 01/15/2023] [Accepted: 01/17/2023] [Indexed: 06/18/2023]
Abstract
Monitoring biomarkers is a great way to assess daily physical condition, and using saliva instead of blood samples is more advantageous as the process is simple and allows individuals to test themselves. In the present study, we analyzed the titers of neutralizing antibodies, IgG and secretory IgA (sIgA), in response to the SARS-CoV-2 vaccine, in saliva. A total of 19 saliva and serum samples were collected over a 10-month period 3 weeks after the first vaccine, 8 months after the second vaccine, and 1 month after the third vaccine. The ranges of antibody concentrations post-vaccination were: serum IgG: 81-15,000 U/mL, salivary IgG: 3.4-330 U/mL, and salivary IgA: 58-870 ng/mL. A sharp increase in salivary IgG levels was observed after the second vaccination. sIgA levels also showed an increasing trend. A correlation with trends in serum IgG levels was observed, indicating the possibility of using saliva to routinely assess vaccine efficacy. The electrochemical immunosensor assay developed in this study based on the gold-linked electrochemical immunoassay, and the antioxidant activity measurement based on luminol electrochemiluminescence (ECL), can be performed using portable devices, which would prove useful for individual-based diagnosis using saliva samples.
Collapse
Affiliation(s)
- Eiichi Tamiya
- Advanced Photonics and Biosensing Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology, Photonics Center, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan
- SANKEN, Osaka University, 8-1 Mihogaoka, Ibaraki 567-0047, Osaka, Japan
| | - Shuto Osaki
- Advanced Photonics and Biosensing Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology, Photonics Center, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan
| | | | - Hiromi Ushijima
- BioDevice Technology Ltd., 2-3 Asahidai, Nomi 923-1211, Ishikawa, Japan
| | - Keiichi Tsukinoki
- Department of Environmental Pathology, Kanagawa Dental University, 82 Inaoka-cho, Yokosuka 238-0003, Kanagawa, Japan
| |
Collapse
|
19
|
Yulianti ES, Rahman SF, Whulanza Y. Molecularly Imprinted Polymer-Based Sensor for Electrochemical Detection of Cortisol. BIOSENSORS 2022; 12:1090. [PMID: 36551057 PMCID: PMC9776045 DOI: 10.3390/bios12121090] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 11/16/2022] [Accepted: 11/23/2022] [Indexed: 06/17/2023]
Abstract
As a steroid hormone, cortisol has a close relationship with the stress response, and therefore, can be used as a biomarker for early detection of stress. An electrochemical immunosensor is one of the most widely used methods to detect cortisol, with antibodies as its bioreceptor. Apart from conventional laboratory-based methods, the trend for cortisol detection has seemed to be exploiting antibodies and aptamers. Both can provide satisfactory performance with high selectivity and sensitivity, but they still face issues with their short shelf life. Molecularly imprinted polymers (MIPs) have been widely used to detect macro- and micro-molecules by forming artificial antibodies as bioreceptors. MIPs are an alternative to natural antibodies, which despite demonstrating high selectivity and a low degree of cross-reactivity, often also show a high sensitivity to the environment, leading to their denaturation. MIPs can be prepared with convenient and relatively affordable fabrication processes. They also have high durability in ambient conditions, a long shelf life, and the ability to detect cortisol molecules at a concentration as low as 2 ag/mL. By collecting data from the past five years, this review summarizes the antibody and aptamer-based amperometric sensors as well as the latest developments exploiting MIPs rather than antibodies. Lastly, factors that can improve MIPs performance and are expected to be developed in the future are also explained.
Collapse
Affiliation(s)
- Elly Septia Yulianti
- Department of Electrical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus UI Depok, Depok 16424, West Java, Indonesia
| | - Siti Fauziyah Rahman
- Department of Electrical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus UI Depok, Depok 16424, West Java, Indonesia
- Research Center for Biomedical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus UI Depok, Depok 16424, West Java, Indonesia
| | - Yudan Whulanza
- Research Center for Biomedical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus UI Depok, Depok 16424, West Java, Indonesia
- Department of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus UI Depok, Depok 16424, West Java, Indonesia
| |
Collapse
|
20
|
A dual-mode biosensor for salivary cortisol with antibody-aptamer sandwich pattern and enzyme catalytic amplification. J Solid State Electrochem 2022. [DOI: 10.1007/s10008-022-05313-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
21
|
Zhang T, Du X, Zhang Z. Advances in electrochemical sensors based on nanomaterials for the detection of lipid hormone. Front Bioeng Biotechnol 2022; 10:993015. [PMID: 36159660 PMCID: PMC9500180 DOI: 10.3389/fbioe.2022.993015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Accepted: 08/12/2022] [Indexed: 11/17/2022] Open
Abstract
Lipid hormone is produced by highly differentiated endocrine cells and directly secretes into the blood circulation or tissue fluid to act as information transmission. It influences the physiological functions of the human body by controlling the metabolic processes of multiple tissue cells. Monitoring the levels of lipid hormone is of great importance for maintaining human health. The electrochemical sensor is considered as an ideal tool to detect lipid hormone owing to its advantages such as quick response, convenience and low economic costs. In recent 3 years, researchers have developed various electrochemical sensors for the detection of lipid hormone to improve their sensitivity or selectivity. The use of nanomaterials (such as carbon nanomaterials, precious metal and polymer) is a key research object and a breakthrough for improving the sensing performance of electrochemical sensors for detection of lipid hormone. This paper reviews and discusses the basic principle, nanomaterials, actuality and future development trend of electrochemical sensors for the detection of lipid hormone in the past 3 years.
Collapse
Affiliation(s)
| | - Xin Du
- *Correspondence: Xin Du, ; Zhenguo Zhang,
| | | |
Collapse
|
22
|
Mesoporous Nanoparticles for Diagnosis and Treatment of Liver Cancer in the Era of Precise Medicine. Pharmaceutics 2022; 14:pharmaceutics14091760. [PMID: 36145508 PMCID: PMC9500788 DOI: 10.3390/pharmaceutics14091760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 08/11/2022] [Accepted: 08/19/2022] [Indexed: 11/16/2022] Open
Abstract
Primary liver cancer is the seventh-most-common cancer worldwide and the fourth-leading cause of cancer mortality. In the current era of precision medicine, the diagnosis and management of liver cancer are full of challenges and prospects. Mesoporous nanoparticles are often designed as specific carriers of drugs and imaging agents because of their special morphology and physical and chemical properties. In recent years, the design of the elemental composition and morphology of mesoporous nanoparticles have greatly improved their drug-loading efficiency, biocompatibility and biodegradability. Especially in the field of primary liver cancer, mesoporous nanoparticles have been modified as highly tumor-specific imaging contrast agents and targeting therapeutic medicine. Various generations of complexes and structures have been determined for the complicated clinical management requirements. In this review, we summarize these advanced mesoporous designs in the different diagnostic and therapeutic fields of liver cancer and discuss the relevant advantages and disadvantages of transforming applications. By comparing the material properties, drug-delivery characteristics and application methods of different kinds of mesoporous materials in liver cancer, we try to help determine the most suitable drug carriers and information media for future clinical trials. We hope to improve the fabrication of biomedical mesoporous nanoparticles and provide direct evidence for specific cancer management.
Collapse
|
23
|
Gu Y, Jiang Y, Gong G, Cheng X, Mei Y, Pan H, Han J. Detection of CYFRA21-1 in serum by electrochemical immunosensor based on nanocomposite consisting of AuNPs@CMK-3@CMWCNTs. Bioelectrochemistry 2022; 148:108230. [PMID: 36029760 DOI: 10.1016/j.bioelechem.2022.108230] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 08/08/2022] [Accepted: 08/09/2022] [Indexed: 11/19/2022]
Abstract
An electrochemical immunosensor based on the modification of nanocomposite was constructed to detect the lung cancer marker Cytokeratin 19 fragment antigen 21-1 (CYFRA21-1). Ordered mesoporous carbon CMK-3 was selected to mix with carboxylated multi-walled carbon nanotubes (CMWCNTs), and their combination could enhance electron transfer efficiency and amplify the electrochemical signal. Furthermore, aurum nanoparticles (AuNPs) were further mixed with the hybrid carbon nanomaterials, which bind antibodies via Au-S bonds and provide numerous of binding sites for antibodies. Finally, CYFRA21-1 could be detected by specific immune response between antigen and antibody by improving the immunosensor sensitivity. The characterization of scanning electron microscopy (SEM) showed that AuNPs were embedded on the surface and interstices of CMK-3@CMWCNTs. The curves of cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) showed that the immunsensor was successfully constructed. The constructed immunosensor had a linear range of 0.5 pg/mL to 105 pg/mL for the detection of CYFRA21-1 in serum, and the correlation coefficient (r) was 0.998, with a detection limit of 0.2 pg/mL. Thus, this method is selective and sensitive for getting the accurate and reliable detection results and provides a new method for the CYFRA21-1 ultrasensitive detection in serum.
Collapse
Affiliation(s)
- Yingying Gu
- School of Public Health, Medical College, Wuhan University of Science and Technology, Wuhan, Hubei 430065, PR China; College of Resource and Environmental Engineering, Wuhan University of Science and Technology, Wuhan, Hubei 430065, PR China; Hubei Province Key Laboratory of Occupational Hazard Identification and Control, Wuhan University of Science and Technology, Wuhan, Hubei 430065, PR China
| | - Yuting Jiang
- School of Public Health, Medical College, Wuhan University of Science and Technology, Wuhan, Hubei 430065, PR China; Hubei Province Key Laboratory of Occupational Hazard Identification and Control, Wuhan University of Science and Technology, Wuhan, Hubei 430065, PR China
| | - Guoao Gong
- School of Public Health, Medical College, Wuhan University of Science and Technology, Wuhan, Hubei 430065, PR China; Hubei Province Key Laboratory of Occupational Hazard Identification and Control, Wuhan University of Science and Technology, Wuhan, Hubei 430065, PR China
| | - Xiong Cheng
- School of Public Health, Soochow University, Suzhou, Jiangsu 215123, PR China
| | - Yong Mei
- School of Public Health, Medical College, Wuhan University of Science and Technology, Wuhan, Hubei 430065, PR China; Hubei Province Key Laboratory of Occupational Hazard Identification and Control, Wuhan University of Science and Technology, Wuhan, Hubei 430065, PR China
| | - Hongzhi Pan
- The Affiliated Zhoupu Hospital, Shanghai University of Medicine and Health, Sciences, Shanghai 201318, PR China.
| | - Jun Han
- College of Resource and Environmental Engineering, Wuhan University of Science and Technology, Wuhan, Hubei 430065, PR China.
| |
Collapse
|
24
|
Electrochemical Immunosensor Modified with Nitrogen-Doped Reduced Graphene Oxide@Carboxylated Multi-Walled Carbon Nanotubes/Chitosan@Gold Nanoparticles for CA125 Detection. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10070272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Lung cancer is one of the malignant tumors with the highest mortality rate, and the detection of its tumor marker carcinoma antigen 125 (CA125) is significant. Here, an electrochemical immunoassay for CA125 was described. Nitrogen-doped reduced graphene oxide (N-rGO), carboxylated multi-walled carbon nanotubes (CMWCNTs) and gold nanoparticles (AuNPs) were applied to co-modify glassy carbon electrode (GCE), after incubation with Anti-CA125, the modified electrode was employed for the specific detection of CA125. The N-rGO@CMWCNTs (Nitrogen-doped reduced graphene oxide@carboxylated multi-walled carbon nanotubes) were used as a matrix, while CS@AuNPs (Chitosan@gold nanoparticles) with high conductivity and biocompatibility was immobilized on it through the reaction between carboxyl groups from CMWCNTs and amino groups, hydroxyl groups from chitosan (CS), resulting in the effect of double signal amplification. The immunosensor demonstrated excellent electrochemical performance with a linear detection range of 0.1 pg mL−1–100 ng mL−1, and the detection limit was as low as 0.04 pg mL−1 (S/N = 3). It had been verified that this method had good precision and high accuracy, and the immunosensor could remain stable for 10 days. This research provided a new method for the detection of CA125 in serum.
Collapse
|
25
|
Ye X, Zhang D, Zeng Y, Wang Y, Qi P. Facile fabrication of highly sensitive and non-label aptasensors based on antifouling amyloid-like protein aggregates. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:2350-2356. [PMID: 35647934 DOI: 10.1039/d2ay00416j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
In this paper, we present a robust and versatile method for developing non-label aptasensors with high sensitivity. Amyloid-like protein aggregates were facilely synthesized with the commonly used passivating agent bovine serum albumin (BSA) in developing biosensors, and the produced amyloid-like phase-transited BSA (PTB) exhibited excellent antifouling performances and robust interfacial adhesion with the electrode surface. In order to improve the detection sensitivity of electrochemical measurements, reduced graphene oxide was electrochemically deposited onto the electrode surface. Moreover, gold nanoparticles were introduced to enhance the conductivity of the PTB film and facilitate subsequent aptamer modification. Two common biological species, adenosine triphosphate (ATP) and cytochrome c (cyt c), were chosen as detection targets, and their corresponding aptasensors were successfully constructed and systematically evaluated. The proposed aptasensors based on the PTB-Au antifouling composite exhibited high sensitivity and specificity towards ATP and cyt c detection, and the detection limits were calculated to be 0.26 nM and 0.64 nM for ATP and cyt c, respectively. Hence, this work provides a simple approach to develop highly sensitive aptasensors without any labeling process, and thus promises its great application in biological analysis.
Collapse
Affiliation(s)
- Xiangyi Ye
- Key Laboratory of Marine Environmental Corrosion and Bio-fouling, Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071, China
- Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), 1 Wenhai Road, Qingdao 266237, China.
| | - Dun Zhang
- Key Laboratory of Marine Environmental Corrosion and Bio-fouling, Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071, China
- University of the Chinese Academy of Sciences, Beijing 100039, China
- Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), 1 Wenhai Road, Qingdao 266237, China.
| | - Yan Zeng
- Key Laboratory of Marine Environmental Corrosion and Bio-fouling, Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071, China
- Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), 1 Wenhai Road, Qingdao 266237, China.
| | - Yingwen Wang
- Key Laboratory of Marine Environmental Corrosion and Bio-fouling, Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071, China
- University of the Chinese Academy of Sciences, Beijing 100039, China
- Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), 1 Wenhai Road, Qingdao 266237, China.
| | - Peng Qi
- Key Laboratory of Marine Environmental Corrosion and Bio-fouling, Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071, China
- University of the Chinese Academy of Sciences, Beijing 100039, China
- Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), 1 Wenhai Road, Qingdao 266237, China.
| |
Collapse
|
26
|
Xu X, Zhu L, Wang X, Lan X, Chu H, Tian H, Xu W. Sandwich capture ultrasensitive sensor based on biohybrid interface for the detection of Cronobacter sakazakii. Appl Microbiol Biotechnol 2022; 106:4287-4296. [PMID: 35616722 DOI: 10.1007/s00253-022-11978-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 05/04/2022] [Accepted: 05/10/2022] [Indexed: 11/29/2022]
Abstract
A simple, rapid and ultrasensitive visual sensing method for the detection of Cronobacter sakazakii (C. sakazakii) based on a biohybrid interface was established. During the entire sensing process, quadruple-cascade amplification showed its superior sensing performance. First, the prepared immunomagnetic beads (IMB) were used to isolate and enrich specific targets from the food matrix. After adding the fusion aptamer, the aptamer sequence specifically recognized the target and formed the immune sandwich structure of antibody-target-fusion aptamer. In addition, the fusion aptamer also included the template sequence of exponential amplification reaction (EXPAR), which contained the antisense sequence of the G-rich sequence. Therefore, a large number of G-rich sequences can be generated after EXPAR can be triggered in the presence of Bst. DNA polymerase, nicking endonuclease, cDNA, and dNTP. They were self-assembled into G-quadruplex structures and then combined with hemin to form G4/hemin DNAzyme, resulting in visible coloration and measuring absorbance at 450 nm for quantitative detection. The assay showed a limit of detection (LOD) of 2 CFU/mL in pure culture and 12 CFU/g in milk powder in optimal conditions. This method provides a promising strategy for rapid and point-of-care testing (POCT) since it does not require DNA extraction, medium culturing, and expensive instrumentation. KEY POINTS: •Single-cell level detection of C. sakazakii with ultrasensitive and rapidness •The fusion aptamer integrated recognition and amplification •Sensing analysis of C. sakazakii based on cascade amplification of biohybrid interface.
Collapse
Affiliation(s)
- Xiuyuan Xu
- College of Food Science and Technology, Hebei Agricultural University, Baoding, Hebei, 071001, People's Republic of China
| | - Longjiao Zhu
- Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health (Institute of Nutrition and Health), China Agricultural University, Tianxiu Road 10, Beijing, 100083, People's Republic of China
| | - Xinxin Wang
- College of Food Science and Technology, Hebei Agricultural University, Baoding, Hebei, 071001, People's Republic of China
| | - Xinyue Lan
- Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health (Institute of Nutrition and Health), China Agricultural University, Tianxiu Road 10, Beijing, 100083, People's Republic of China
| | - Huashuo Chu
- Key Laboratory of Safety Assessment of Genetically Modified Organism (Food Safety) (MOA), Beijing Laboratory for Food Quality and Safety, College of Food Science & Nutritional Engineering, Beijing, 100083, People's Republic of China
| | - Hongtao Tian
- College of Food Science and Technology, Hebei Agricultural University, Baoding, Hebei, 071001, People's Republic of China.
| | - Wentao Xu
- Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health (Institute of Nutrition and Health), China Agricultural University, Tianxiu Road 10, Beijing, 100083, People's Republic of China. .,Key Laboratory of Safety Assessment of Genetically Modified Organism (Food Safety) (MOA), Beijing Laboratory for Food Quality and Safety, College of Food Science & Nutritional Engineering, Beijing, 100083, People's Republic of China.
| |
Collapse
|
27
|
Nanoparticle-Mediated Signaling for Aptamer-Based Multiplexed Detection of Cortisol and Neuropeptide Y in Serum. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10050153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Multiplexed profiling of the expression of neurochemical biomarkers of stress, for periodic assessment to enable augmentation of human performance, requires wash-free detection platforms that exhibit reproducible signals from samples in biological matrices. However, alterations in aptamer conformation after binding to targets, such as cortisol, are minimal based on NMR spectra, and the methylene blue signaling is blocked by serum proteins. Hence, in this study, we explore aptamer derivatization with magnetic nanoparticles that are conjugated with multiple methylene blue moieties, to amplify signals and alter the net charge configuration for repulsing serum proteins, so that the aptamer conformation upon target recognition can lead to a signal ON assay in serum media. Based on this, a microchip platform with addressable electrodes that are immobilized with selective aptamer receptors is developed for multiplexed detection of cortisol (1–700 ng/mL) and neuropeptide Y (5–1000 pg/mL) in patient-derived serum samples, which is validated by immunoassays. We envision the application of this sensor for profiling a wider array of human performance biomarkers under stress-related events to develop stress augmentation methodologies.
Collapse
|
28
|
Pundir M, Papagerakis S, De Rosa MC, Chronis N, Kurabayashi K, Abdulmawjood S, Prince MEP, Lobanova L, Chen X, Papagerakis P. Emerging biotechnologies for evaluating disruption of stress, sleep, and circadian rhythm mechanism using aptamer-based detection of salivary biomarkers. Biotechnol Adv 2022; 59:107961. [DOI: 10.1016/j.biotechadv.2022.107961] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 03/30/2022] [Accepted: 04/09/2022] [Indexed: 12/26/2022]
|
29
|
Li M, Singh R, Marques C, Zhang B, Kumar S. 2D material assisted SMF-MCF-MMF-SMF based LSPR sensor for creatinine detection. OPTICS EXPRESS 2021; 29:38150-38167. [PMID: 34808874 DOI: 10.1364/oe.445555] [Citation(s) in RCA: 39] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
The purpose of this work is to propose a simple, portable, and sensitive biosensor structure based on singlemode fiber-multicore fiber-multimode fiber-singlemode fiber (SMF-MCF-MMF-SMF) for the detection of creatinine in the human body. Chemical etching has been used to modify the diameter of the sensing probe to approximately 90 μm in order to generate strong evanescent waves (EWs). The sensor probe is functionalized with graphene oxide (GO), gold nanoparticles (AuNPs), molybdenum disulfide nanoparticles (MoS2-NPs), and creatininase (CA) enzyme. The concentration of creatinine is determined using fiber optic localized surface plasmon resonance (LSPR). While EWs are used to enhance the LSPR effect of AuNPs, two-dimensional (2D) materials (GO and MoS2-NPs) are used to increase biocompatibility, and CA is used to increase probe specificity. Additionally, HR-TEM and UV-visible spectroscopy are used to characterize and measure the nanoparticle (NP) morphology and absorption spectrum, respectively. SEM is used to characterize the NPs immobilized on the surface of the fiber probe. The sensor probe's reusability, reproducibility, stability, selectivity, and pH test results are also tested to verify the sensor performance. The sensitivity of proposed sensor is 0.0025 nm/μM, has a standard deviation of 0.107, and has a limit of detection of 128.4 μM over a linear detection range of 0 - 2000 μM.
Collapse
|
30
|
Singh N, Chung S, Sveiven M, Hall DA. Cortisol Detection in Undiluted Human Serum Using a Sensitive Electrochemical Structure-Switching Aptamer over an Antifouling Nanocomposite Layer. ACS OMEGA 2021; 6:27888-27897. [PMID: 34722988 PMCID: PMC8552316 DOI: 10.1021/acsomega.1c03552] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Accepted: 09/16/2021] [Indexed: 05/16/2023]
Abstract
There is a strong and growing need to monitor stress biomarkers in vivo for real-time emotional and wellness assessment. Toward this, we report a reagent-free electrochemical aptasensor with a nanocomposite antifouling layer for sensitive and continuous detection of cortisol in human serum. A thiolated, methylene blue (MB)-tagged conformation-switching aptamer was immobilized over a gold nanowire (AuNW) nanocomposite to capture cortisol and generate a signal proportional to the cortisol concentration. The signal is recorded through differential pulse voltammetry (DPV) and chronoamperometry. The aptasensor exhibited a sensitive response with 0.51 and 0.68 nM detection limits in spiked buffer and undiluted serum samples, respectively. Interference from other structurally similar analogs, namely, epinephrine and cholic acid, was negligible (<10%). The developed nanocomposite-based aptasensor showed excellent stability in undiluted human serum, outperforming several other nanocomposite materials even after prolonged exposure. This work lays the foundation for new biosensor formats such as implantable and wearable sensors.
Collapse
Affiliation(s)
- Naveen
K. Singh
- Department
of Electrical and Computer Engineering, University of California—San Diego, La Jolla, California 92093, United States
| | - Saeromi Chung
- Department
of Electrical and Computer Engineering, University of California—San Diego, La Jolla, California 92093, United States
| | - Michael Sveiven
- Department
of Bioengineering, University of California—San
Diego, La Jolla, California 92093, United States
| | - Drew A. Hall
- Department
of Electrical and Computer Engineering, University of California—San Diego, La Jolla, California 92093, United States
- Department
of Bioengineering, University of California—San
Diego, La Jolla, California 92093, United States
| |
Collapse
|