Lustermans D, Abdulrahim R, Taasti VT, Szkitsak J, Švėgždaitė E, Clarkin S, Reniers B, Verhaegen F, Paiva Fonseca G. Development of a novel 3D-printed dynamic anthropomorphic thorax phantom for evaluation of four-dimensional computed tomography. Phys Imaging Radiat Oncol 2024; 32:100656. [PMID: 39526020 PMCID: PMC11546439 DOI: 10.1016/j.phro.2024.100656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2024] [Revised: 10/04/2024] [Accepted: 10/15/2024] [Indexed: 11/16/2024] Open
Abstract
Background and purpose In radiotherapy, the image quality of four-dimensional computed tomography (4DCT) is often degraded by artifacts resulting from breathing irregularities. Quality assurance mostly employ simplistic phantoms, not fully representing complexities and dynamics in patients. 3D-printing allows for design of highly customized phantoms. This study aims to validate the proof-of-concept of a realistic dynamic thorax phantom and its 4DCT application. Materials and methods Using 3D-printing, a realistic thorax phantom was produced with tissue-equivalent materials for soft tissue, bone, and compressible lungs, including bronchi and tumors. Lung compression was facilitated by motors simulating customized breathing curves with an added platform for application of monitoring systems. The phantom contained three tumors which were assessed in terms of tumor motion amplitude. Three 4DCT sequences and repeated static images for different lung compression levels were acquired to evaluate the reproducibility. Moreover, more complex patient-specific breathing patterns with irregularities were simulated. Results The phantom showed a reproducibility of ±0.2 mm and ±0.4 mm in all directions for static 3DCT images and 4DCT images, respectively. Furthermore, the tumor close to the diaphragm showed higher amplitudes in the inferior/superior direction (13.9 mm) than lesions higher in the lungs (8.1 mm) as observed in patients. The more complex breathing patterns demonstrated commonly seen 4DCT artifacts. Conclusion This study developed a dynamic 3D-printed thorax phantom, which simulated customized breathing patterns. The phantom represented a realistic anatomy and 4DCT scanning of it could create realistic artifacts, making it beneficial for 4DCT quality assurance or protocol optimization.
Collapse
Affiliation(s)
- Didier Lustermans
- Department of Radiation Oncology (Maastro), GROW Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Roua Abdulrahim
- Department of Radiation Oncology (Maastro), GROW Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
- Research Group NuTeC, Centre for Environmental Sciences, Hasselt University, Diepenbeek, Belgium
| | - Vicki Trier Taasti
- Department of Radiation Oncology (Maastro), GROW Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| | - Juliane Szkitsak
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Evita Švėgždaitė
- Department of Radiation Oncology (Maastro), GROW Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Sarina Clarkin
- Department of Radiation Oncology (Maastro), GROW Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Brigitte Reniers
- Research Group NuTeC, Centre for Environmental Sciences, Hasselt University, Diepenbeek, Belgium
| | - Frank Verhaegen
- Department of Radiation Oncology (Maastro), GROW Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Gabriel Paiva Fonseca
- Department of Radiation Oncology (Maastro), GROW Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| |
Collapse
|
2
|
van Wagenberg T, Voncken R, van Beveren C, Berbee M, van Limbergen E, Verhaegen F, Paiva Fonseca G. Time-resolved clinical dose volume metrics, calculations and predictions based on source tracking measurements and uncertainties to aid treatment verification and error detection for HDR brachytherapy-a proof-of-principle study. Phys Med Biol 2024; 69:135006. [PMID: 38870948 DOI: 10.1088/1361-6560/ad580e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 06/13/2024] [Indexed: 06/15/2024]
Abstract
Objective.High-dose-rate (HDR) brachytherapy lacks routinely available treatment verification methods. Real-time tracking of the radiation source during HDR brachytherapy can enhance treatment verification capabilities. Recent developments in source tracking allow for measurement of dwell times and source positions with high accuracy. However, more clinically relevant information, such as dose discrepancies, is still needed. To address this, a real-time dose calculation implementation was developed to provide more relevant information from source tracking data. A proof-of-principle of the developed tool was shown using source tracking data obtained from a 3D-printed anthropomorphic phantom.Approach.Software was developed to calculate dose-volume-histograms (DVH) and clinical dose metrics from experimental HDR prostate treatment source tracking data, measured in a realistic pelvic phantom. Uncertainty estimation was performed using repeat measurements to assess the inherent dose measuring uncertainty of thein vivodosimetry (IVD) system. Using a novel approach, the measurement uncertainty can be incorporated in the dose calculation, and used for evaluation of cumulative dose and clinical dose-volume metrics after every dwell position, enabling real-time treatment verification.Main results.The dose calculated from source tracking measurements aligned with the generated uncertainty bands, validating the approach. Simulated shifts of 3 mm in 5/17 needles in a single plan caused DVH deviations beyond the uncertainty bands, indicating errors occurred during treatment. Clinical dose-volume metrics could be monitored in a time-resolved approach, enabling early detection of treatment plan deviations and prediction of their impact on the final dose that will be delivered in real-time.Significance.Integrating dose calculation with source tracking enhances the clinical relevance of IVD methods. Phantom measurements show that the developed tool aids in tracking treatment progress, detecting errors in real-time and post-treatment evaluation. In addition, it could be used to define patient-specific action limits and error thresholds, while taking the uncertainty of the measurement system into consideration.
Collapse
Affiliation(s)
- Teun van Wagenberg
- Department of Radiation Oncology (Maastro), GROW-Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Robert Voncken
- Department of Radiation Oncology (Maastro), GROW-Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Celine van Beveren
- Department of Radiation Oncology (Maastro), GROW-Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Maaike Berbee
- Department of Radiation Oncology (Maastro), GROW-Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Evert van Limbergen
- Department of Radiation Oncology (Maastro), GROW-Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Frank Verhaegen
- Department of Radiation Oncology (Maastro), GROW-Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Gabriel Paiva Fonseca
- Department of Radiation Oncology (Maastro), GROW-Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| |
Collapse
|
3
|
Fahimian BP, Liu W, Skinner L, Yu AS, Phillips T, Steers JM, DeMarco J, Fraass BA, Kamrava M. 3D printing in brachytherapy: A systematic review of gynecological applications. Brachytherapy 2023; 22:446-460. [PMID: 37024350 DOI: 10.1016/j.brachy.2023.02.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 12/27/2022] [Accepted: 02/02/2023] [Indexed: 04/08/2023]
Abstract
PURPOSE To provide a systematic review of the applications of 3D printing in gynecological brachytherapy. METHODS Peer-reviewed articles relating to additive manufacturing (3D printing) from the 34 million plus biomedical citations in National Center for Biotechnology Information (NCBI/PubMed), and 53 million records in Web of Science (Clarivate) were queried for 3D printing applications. The results were narrowed sequentially to, (1) all literature in 3D printing with final publications prior to July 2022 (in English, and excluding books, proceedings, and reviews), and then to applications in, (2) radiotherapy, (3) brachytherapy, (4) gynecological brachytherapy. Brachytherapy applications were reviewed and grouped by disease site, with gynecological applications additionally grouped by study type, methodology, delivery modality, and device type. RESULTS From 47,541 3D printing citations, 96 publications met the inclusion criteria for brachytherapy, with gynecological clinical applications compromising the highest percentage (32%), followed by skin and surface (19%), and head and neck (9%). The distribution of delivery modalities was 58% for HDR (Ir-192), 35% for LDR (I-125), and 7% for other modalities. In gynecological brachytherapy, studies included design of patient specific applicators and templates, novel applicator designs, applicator additions, quality assurance and dosimetry devices, anthropomorphic gynecological applicators, and in-human clinical trials. Plots of year-to-year growth demonstrate a rapid nonlinear trend since 2014 due to the improving accessibility of low-cost 3D printers. Based on these publications, considerations for clinical use are provided. CONCLUSIONS 3D printing has emerged as an important clinical technology enabling customized applicator and template designs, representing a major advancement in the methodology for implantation and delivery in gynecological brachytherapy.
Collapse
Affiliation(s)
- Benjamin P Fahimian
- Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, CA.
| | - Wu Liu
- Department of Radiation Oncology, Stanford University, Stanford, CA
| | - Lawrie Skinner
- Department of Radiation Oncology, Stanford University, Stanford, CA
| | - Amy S Yu
- Department of Radiation Oncology, Stanford University, Stanford, CA
| | - Tiffany Phillips
- Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, CA
| | - Jennifer M Steers
- Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, CA
| | - John DeMarco
- Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, CA
| | - Benedick A Fraass
- Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, CA
| | - Mitchell Kamrava
- Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, CA
| |
Collapse
|
4
|
Fonseca GP, Rezaeifar B, Lackner N, Haanen B, Reniers B, Verhaegen F. Dual-energy CT evaluation of 3D printed materials for radiotherapy applications. Phys Med Biol 2023; 68. [PMID: 36584391 DOI: 10.1088/1361-6560/acaf4a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Accepted: 12/30/2022] [Indexed: 12/31/2022]
Abstract
Objective. There is a continuous increase in 3D printing applications in several fields including medical imaging and radiotherapy. Although there are numerous advantages of using 3D printing for the development of customized phantoms, bolus, quality assurance devices and other clinical applications, material properties are not well known and printer settings can affect considerably the properties (e.g. density, isotropy and homogeneity) of the printed parts. This study aims to evaluate several materials and printer properties to identify a range of tissue-mimicking materials.Approach. Dual-energy CT was used to obtain the effective atomic number (Zeff) and relative electron density (RED) for thirty-one different materials including different colours of the same filament from the same manufacturer and the same type of filament from different manufacturers. In addition, a custom bone equivalent filament was developed and evaluated since a high-density filament with a composition similar to bone is not commercially available. Printing settings such as infill density, infill pattern, layer height and nozzle size were also evaluated.Main results. Large differences were observed for HU (288), RED (>10%) andZeff(>50%) for different colours of the same filament due to the colour pigment. Results show a wide HU variation (-714 to 1104), RED (0.277 to 1.480) andZeff(5.22 to 12.39) between the printed samples with some materials being comparable to commercial tissue-mimicking materials and good substitutes to a range of materials from lung to bone. Printer settings can result in directional dependency and significantly affect the homogeneity of the samples.Significance. The use of DECT to extract RED, andZeffallows for quantitative imaging and dosimetry using 3D printed materials equivalent to certified tissue-mimicking tissues.
Collapse
Affiliation(s)
- Gabriel P Fonseca
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Behzad Rezaeifar
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Niklas Lackner
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Britt Haanen
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Brigitte Reniers
- Research group NuTeC, Centre for Environmental Sciences, Hasselt University, Diepenbeek, Belgium
| | - Frank Verhaegen
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands
| |
Collapse
|
5
|
In Vivo Verification of Treatment Source Dwell Times in Brachytherapy of Postoperative Endometrial Carcinoma: A Feasibility Study. J Pers Med 2022; 12:jpm12060911. [PMID: 35743696 PMCID: PMC9224704 DOI: 10.3390/jpm12060911] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 05/24/2022] [Accepted: 05/28/2022] [Indexed: 11/17/2022] Open
Abstract
(1) Background: In brachytherapy, there are still many manual procedures that can cause adverse events which can be detected with in vivo dosimetry systems. Plastic scintillator dosimeters (PSD) have interesting properties to achieve this objective such as real-time reading, linearity, repeatability, and small size to fit inside brachytherapy catheters. The purpose of this study was to evaluate the performance of a PSD in postoperative endometrial brachytherapy in terms of source dwell time accuracy. (2) Methods: Measurements were carried out in a PMMA phantom to characterise the PSD. Patient measurements in 121 dwell positions were analysed to obtain the differences between planned and measured dwell times. (3) Results: The repeatability test showed a relative standard deviation below 1% for the measured dwell times. The relative standard deviation of the PSD sensitivity with accumulated absorbed dose was lower than 1.2%. The equipment operated linearly in total counts with respect to absorbed dose and also in count rate versus absorbed dose rate. The mean (standard deviation) of the absolute differences between planned and measured dwell times in patient treatments was 0.0 (0.2) seconds. (4) Conclusions: The PSD system is useful as a quality assurance tool for brachytherapy treatments.
Collapse
|