Vieira MLC, Silva MC, Wagner CR, Dallan LA, Kajita LJ, Oliveira WA, Samesina N, Hotta VT, Mathias W, Spina G, Cardoso L, Pastore CA, Tarasoutchi F, Grinberg M. Left atrium reverse remodeling in patients with mitral valve stenosis after percutaneous valvuloplasty: a 2- and 3-dimensional echocardiographic study.
Rev Esp Cardiol 2012;
66:17-23. [PMID:
22878092 DOI:
10.1016/j.recesp.2012.05.007]
[Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2012] [Accepted: 05/17/2012] [Indexed: 11/19/2022]
Abstract
INTRODUCTION AND OBJECTIVES
The left atrium is clinically relevant in patients with mitral valve stenosis. The objective of this study was to analyze the effects of percutaneous balloon valvuloplasty on left atrium volumes and the left atrium emptying fraction in symptomatic mitral valve stenosis patients using 2-dimensional and real-time 3 -dimensional transthoracic echocardiography.
METHODS
We carried out a prospective study of 28 consecutive symptomatic mitral valve stenosis patients, aged 22-72 (39 [11.5]) years, 24/28 (85.6%) women, who underwent to percutaneous balloon valvuloplasty between March 2009 and May 2011. Patients underwent 2- and 3-dimensional transthoracic and transesophageal echocardiography (atrial fibrillation) and invasive mitral valve area measurement. Echocardiographic analysis was performed before, 72 h after and 12 months after percutaneous balloon valvuloplasty. The following parameters were analyzed: a) mitral valve area (2-dimensional planimetry, pressure half-time, 3-dimensional echocardiography, invasive hemodynamic measurement); b) indexed left atrium maximum and indexed minimum volumes, and c) left atrium emptying fraction.
RESULTS
The 3-dimensional parameters of the mitral valve stenosis patients before and 72 h and 12 months after percutaneous balloon valvuloplasty were as follows: a) mitral valve area: 0.9 (0.1) cm(2); 1.8 (0.2) cm(2) (P<.001); 1.7 (0.2) cm(2) (P<.001); b) left atrium maximum volumes: 49.9 (12) mL/m(2); 42 (11.4) mL/m(2) (P<.001); 40.3 (10.2) mL/m(2) (P<.001), and c) left atrium emptying fraction: 30.1 (9.4%); 40.6 (7.4%) (P<.001); 44.1 (8%) (P<.001), respectively.
CONCLUSIONS
In symptomatic mitral valve stenosis patients who underwent percutaneous balloon valvuloplasty analysis by 2- and 3-dimensional echocardiography, improvements in left atrium reverse remodeling and left atrium emptying fraction were observed 72 h and 12 months after the procedure.
Collapse