1
|
Karunarathne AD, Pathiratne A. Combined use of ecotoxicity tools and physicochemical analysis for evaluating potential toxicity of treated natural rubber processing effluents and receiving waters. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024:10.1007/s11356-024-33900-y. [PMID: 38856856 DOI: 10.1007/s11356-024-33900-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Accepted: 05/31/2024] [Indexed: 06/11/2024]
Abstract
Potential toxicity of treated effluents of selected natural rubber processing industries was evaluated by integrating physicochemical analysis with Daphnia magna and Poecilia reticulata bioassays as ecotoxicity tools. Further, the efficacy of the constructed wetland treatments practiced by the industries for reducing the ecotoxicity of the final effluents reaching the receiving water course was assessed. Even after passing through the constructed wetlands, some of the measured physicochemical parameters of the final effluents did not comply with the stipulated rubber processing effluent regulatory limits. Acute toxicity data of treated effluents demonstrated greater susceptibility of D. magna compared to P. reticulata. Erythrocytic abnormality tests with P. reticulata revealed that rubber industry effluents contained cytogenotoxic contaminations which had not been completely eliminated by the treatment processes. Wetland treatment technique was not effective in reducing the cytogenotoxic effects of final effluents reaching the receiving water course. The use of ecotoxicity tools for optimization of rubber industry effluent treatment processes would help to reduce potential toxic/cytogenotoxic effects of effluent receiving waterbodies considering sustainable development goals focusing on ecosystem safety.
Collapse
Affiliation(s)
- Ahinsa Dewthilini Karunarathne
- Department of Zoology and Environmental Management, Faculty of Science, University of Kelaniya, Kelaniya, GQ 11600, Sri Lanka
| | - Asoka Pathiratne
- Department of Zoology and Environmental Management, Faculty of Science, University of Kelaniya, Kelaniya, GQ 11600, Sri Lanka.
| |
Collapse
|
2
|
Kharkova AS, Medvedeva AS, Kuznetsova LS, Gertsen MM, Kolesov VV, Arlyapov VA, Reshetilov AN. A "2-in-1" Bioanalytical System Based on Nanocomposite Conductive Polymers for Early Detection of Surface Water Pollution. Polymers (Basel) 2024; 16:1431. [PMID: 38794624 PMCID: PMC11125136 DOI: 10.3390/polym16101431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Revised: 05/02/2024] [Accepted: 05/10/2024] [Indexed: 05/26/2024] Open
Abstract
This work proposes an approach to the formation of receptor elements for the rapid diagnosis of the state of surface waters according to two indicators: the biochemical oxygen demand (BOD) index and toxicity. Associations among microorganisms based on the bacteria P. yeei and yeast S. cerevisiae, as well as associations of the yeasts O. polymorpha and B. adeninivorans, were formed to evaluate these indicators, respectively. The use of nanocomposite electrically conductive materials based on carbon nanotubes, biocompatible natural polymers-chitosan and bovine serum albumin cross-linked with ferrocenecarboxaldehyde, neutral red, safranin, and phenosafranin-has made it possible to expand the analytical capabilities of receptor systems. Redox polymers were studied by IR spectroscopy and Raman spectroscopy, the contents of electroactive components were determined by atomic absorption spectroscopy, and electrochemical properties were studied by electrochemical impedance and cyclic voltammetry methods. Based on the proposed kinetic approach to modeling individual stages of bioelectrochemical processes, the chitosan-neutral red/CNT composite was chosen to immobilize the yeast association between O. polymorpha (ks = 370 ± 20 L/g × s) and B. adeninivorans (320 ± 30 L/g × s), and a bovine serum albumin (BSA)-neutral composite was chosen to immobilize the association between the yeast S. cerevisiae (ks = 130 ± 10 L/g × s) and the bacteria P. yeei red/CNT (170 ± 30 L/g × s). After optimizing the composition of the receptor systems, it was shown that the use of nanocomposite materials together with associations among microorganisms makes it possible to determine BOD with high sensitivity (with a lower limit of 0.6 mg/dm3) and detect the presence of a wide range of toxicants of both organic and inorganic origin. Both receptor elements were tested on water samples, showing a high correlation between the results of biosensor analysis of BOD and toxicity and the results of standard analytical methods. The results obtained show broad prospects for creating sensitive and portable bioelectrochemical sensors for the early warning of environmentally hazardous situations based on associations among microorganisms and nanocomposite materials.
Collapse
Affiliation(s)
- Anna S. Kharkova
- The Research Center «BioChemTech», Tula State University, 300012 Tula, Russia; (A.S.K.); (A.S.M.); (L.S.K.)
| | - Anastasia S. Medvedeva
- The Research Center «BioChemTech», Tula State University, 300012 Tula, Russia; (A.S.K.); (A.S.M.); (L.S.K.)
| | - Lyubov S. Kuznetsova
- The Research Center «BioChemTech», Tula State University, 300012 Tula, Russia; (A.S.K.); (A.S.M.); (L.S.K.)
| | - Maria M. Gertsen
- Laboratory of Soil Chemistry and Ecology, Tula State Lev Tolstoy Pedagogical University, 300026 Tula, Russia;
| | - Vladimir V. Kolesov
- Kotelnikov Institute of Radioengineering and Electronics (IRE) of Russian Academy of Sciences, 111250 Moscow, Russia;
| | - Vyacheslav A. Arlyapov
- The Research Center «BioChemTech», Tula State University, 300012 Tula, Russia; (A.S.K.); (A.S.M.); (L.S.K.)
| | - Anatoly N. Reshetilov
- Federal Research Center «Pushchino Scientific Center for Biological Research of the Russian Academy of Sciences», G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Russian Academy of Sciences, 142290 Pushchino, Russia;
| |
Collapse
|
3
|
Zhou Z, Wu F, Tong Y, Zhang S, Li L, Cheng F, Zhang B, Zeng X, Yu Z, You J. Toxicity and chemical characterization of shale gas wastewater discharged to the receiving water: Evidence from toxicity identification evaluation. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 912:169510. [PMID: 38154638 DOI: 10.1016/j.scitotenv.2023.169510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 12/17/2023] [Accepted: 12/17/2023] [Indexed: 12/30/2023]
Abstract
Flowback and produced water (FPW) generated from shale gas extraction is a complex mixture consisting of injected drilling fluid, deep formation water, and byproducts of downhole reactions. Limited knowledge is available regarding the impact of discharged FPW on surface water in China. With the development of shale gas exploitation, this emphasizes an urgent need for comprehensive assessments and stringent regulations to ensure the safe disposal of shale gas extraction-related wastewater. Herein, we explored potential impacts of treated shale gas wastewater discharged into a local river in southwest China through toxicity identification evaluation (TIE). Results revealed that organics and particulates significantly contributed to the overall toxicity of the treated FPW wastewater. Through target and suspect chemical analyses, various categories of organic contaminants were detected, including alkanes, aromatic hydrocarbons, biocides, phenols, and phthalates. Furthermore, non-target analysis uncovered the presence of surfactant-related contaminants in tissues of exposed organisms, but their contribution to the observed toxicity was unclear due to the lack of effect data for these compounds. Higher toxicity was found at the discharge point compared with upstream sites; however, the toxicity was rapidly mitigated due to dilution in the receiving river, posing little impact on downstream areas. Our study highlighted the importance of monitoring toxicity and water quality of FPW effluent even though dilution could be a viable approach when the water volume in the discharge was small.
Collapse
Affiliation(s)
- Zhimin Zhou
- School of Environment and Guangdong Key Laboratory of Environmental Pollution and Health, Jinan University, Guangzhou 510632, China; State Environmental Protection Key Laboratory of Environmental Pollution Health Risk Assessment, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, Guangzhou 510655, China
| | - Fan Wu
- School of Environment and Guangdong Key Laboratory of Environmental Pollution and Health, Jinan University, Guangzhou 510632, China.
| | - Yujun Tong
- School of Environment and Guangdong Key Laboratory of Environmental Pollution and Health, Jinan University, Guangzhou 510632, China
| | - Shaoqiong Zhang
- School of Environment and Guangdong Key Laboratory of Environmental Pollution and Health, Jinan University, Guangzhou 510632, China
| | - Liang Li
- School of Environment and Guangdong Key Laboratory of Environmental Pollution and Health, Jinan University, Guangzhou 510632, China
| | - Fei Cheng
- School of Environment and Guangdong Key Laboratory of Environmental Pollution and Health, Jinan University, Guangzhou 510632, China
| | - Biao Zhang
- State Key Laboratory of Organic Geochemistry, Guangdong Key Laboratory of Environment and Resources, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640, China
| | - Xiangying Zeng
- State Key Laboratory of Organic Geochemistry, Guangdong Key Laboratory of Environment and Resources, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640, China
| | - Zhiqiang Yu
- State Key Laboratory of Organic Geochemistry, Guangdong Key Laboratory of Environment and Resources, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640, China
| | - Jing You
- School of Environment and Guangdong Key Laboratory of Environmental Pollution and Health, Jinan University, Guangzhou 510632, China
| |
Collapse
|