1
|
Cao Y, Khan A, Tazikeh-Lemeski E, Javan M, Baei MT, Ramezani Taghartapeh M, Mighani H, Soltani A, Pishnamazi M, Nouri A, Albadarin AB. Modeling and simulation of external electric field application for diisopropyl methylphosphonate sensing through B12N12 fullerene. J Mol Liq 2021. [DOI: 10.1016/j.molliq.2021.116845] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
2
|
|
3
|
Petkovic K, Swallow A, Stewart R, Gao Y, Li S, Glenn F, Gotama J, Dell'Olio M, Best M, Doward J, Ovendon S, Zhu Y. An Integrated Portable Multiplex Microchip Device for Fingerprinting Chemical Warfare Agents. MICROMACHINES 2019; 10:E617. [PMID: 31527486 PMCID: PMC6780382 DOI: 10.3390/mi10090617] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2019] [Revised: 09/09/2019] [Accepted: 09/11/2019] [Indexed: 01/01/2023]
Abstract
The rapid and reliable detection of chemical and biological agents in the field is important for many applications such as national security, environmental monitoring, infectious diseases screening, and so on. Current commercially available devices may suffer from low field deployability, specificity, and reproducibility, as well as a high false alarm rate. This paper reports the development of a portable lab-on-a-chip device that could address these issues. The device integrates a polymer multiplexed microchip system, a contactless conductivity detector, a data acquisition and signal processing system, and a graphic/user interface. The samples are pre-treated by an on-chip capillary electrophoresis system. The separated analytes are detected by conductivity-based microsensors. Extensive studies are carried out to achieve satisfactory reproducibility of the microchip system. Chemical warfare agents soman (GD), sarin (GB), O-ethyl S-[2-diisoproylaminoethyl] methylphsophonothioate (VX), and their degradation products have been tested on the device. It was demonstrated that the device can fingerprint the tested chemical warfare agents. In addition, the detection of ricin and metal ions in water samples was demonstrated. Such a device could be used for the rapid and sensitive on-site detection of both chemical and biological agents in the future.
Collapse
Affiliation(s)
| | | | - Robert Stewart
- CSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia
| | - Yuan Gao
- CSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia
| | - Sheng Li
- CSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia
| | - Fiona Glenn
- CSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia
| | - Januar Gotama
- CSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia
| | - Mel Dell'Olio
- CSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia
| | - Michael Best
- CSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia
| | - Justin Doward
- DST, 506 Lorimer Street, Fishermans Bend, VIC 3207, Australia
| | - Simon Ovendon
- DST, 506 Lorimer Street, Fishermans Bend, VIC 3207, Australia
| | - Yonggang Zhu
- CSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia.
- Harbin Institute of Technology (Shenzhen), Shenzhen, Guangdong 518055, China.
- School of Science, RMIT University, Melbourne, VIC 3001, Australia.
| |
Collapse
|
4
|
Chemical Analysis of Dumped Chemical Warfare Agents During the MODUM Project. NATO SCIENCE FOR PEACE AND SECURITY SERIES C: ENVIRONMENTAL SECURITY 2018. [DOI: 10.1007/978-94-024-1153-9_4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
5
|
Tan C, Nasir MZM, Ambrosi A, Pumera M. 3D Printed Electrodes for Detection of Nitroaromatic Explosives and Nerve Agents. Anal Chem 2017; 89:8995-9001. [DOI: 10.1021/acs.analchem.7b01614] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Cavin Tan
- Division of Chemistry & Biological Chemistry, School of Physical Mathematical Science, Nanyang Technological University, Singapore 637371, Singapore
| | - Muhammad Zafir Mohamad Nasir
- Division of Chemistry & Biological Chemistry, School of Physical Mathematical Science, Nanyang Technological University, Singapore 637371, Singapore
| | - Adriano Ambrosi
- Division of Chemistry & Biological Chemistry, School of Physical Mathematical Science, Nanyang Technological University, Singapore 637371, Singapore
| | - Martin Pumera
- Division of Chemistry & Biological Chemistry, School of Physical Mathematical Science, Nanyang Technological University, Singapore 637371, Singapore
| |
Collapse
|
6
|
Ali I, Alharbi OML, Marsin Sanagi M. Nano-capillary electrophoresis for environmental analysis. ENVIRONMENTAL CHEMISTRY LETTERS 2015; 14:79-98. [PMID: 32214934 PMCID: PMC7087629 DOI: 10.1007/s10311-015-0547-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2015] [Accepted: 12/11/2015] [Indexed: 06/10/2023]
Abstract
Many analytical techniques have been used to monitor environmental pollutants. But most techniques are not capable to detect pollutants at nanogram levels. Hence, under such conditions, absence of pollutants is often assumed, whereas pollutants are in fact present at low but undetectable concentrations. Detection at low levels may be done by nano-capillary electrophoresis, also named microchip electrophoresis. Here, we review the analysis of pollutants by nano-capillary electrophoresis. We present instrumentations, applications, optimizations and separation mechanisms. We discuss the analysis of metal ions, pesticides, polycyclic aromatic hydrocarbons, explosives, viruses, bacteria and other contaminants. Detectors include ultraviolet-visible, fluorescent, conductivity, atomic absorption spectroscopy, refractive index, atomic fluorescence spectrometry, atomic emission spectroscopy, inductively coupled plasma, inductively coupled plasma-mass spectrometry, mass spectrometry, time-of-flight mass spectrometry and nuclear magnetic resonance. Detection limits ranged from nanogram to picogram levels.
Collapse
Affiliation(s)
- Imran Ali
- Department of Chemistry, Jamia Millia Islamia (Central University), New Delhi, 110025 India
| | - Omar M. L. Alharbi
- Biology Department, Faculty of Sciences, Taibah University, P.O. Box 30002, Madinah Al-Munawarah, 41477 Saudi Arabia
| | - Mohd. Marsin Sanagi
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia (UTM), 81310 Johor Bahru, Johor Malaysia
- Ibnu Sina Institute for Fundamental Science Studies, Nanotechnology Research Alliance, Universiti Teknologi Malaysia (UTM), 81310 Johor Bahru, Johor Malaysia
| |
Collapse
|
7
|
da Costa ET, Neves CA, Hotta GM, Vidal DTR, Barros MF, Ayon AA, Garcia CD, do Lago CL. Unmanned platform for long-range remote analysis of volatile compounds in air samples. Electrophoresis 2012; 33:2650-9. [PMID: 22965708 DOI: 10.1002/elps.201200273] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
This paper describes a long-range remotely controlled CE system built on an all-terrain vehicle. A four-stroke engine and a set of 12-V batteries were used to provide power to a series of subsystems that include drivers, communication, computers, and a capillary electrophoresis module. This dedicated instrument allows air sampling using a polypropylene porous tube, coupled to a flow system that transports the sample to the inlet of a fused-silica capillary. A hybrid approach was used for the construction of the analytical subsystem combining a conventional fused-silica capillary (used for separation) and a laser machined microfluidic block, made of PMMA. A solid-state cooling approach was also integrated in the CE module to enable controlling the temperature and therefore increasing the useful range of the robot. Although ultimately intended for detection of chemical warfare agents, the proposed system was used to analyze a series of volatile organic acids. As such, the system allowed the separation and detection of formic, acetic, and propionic acids with signal-to-noise ratios of 414, 150, and 115, respectively, after sampling by only 30 s and performing an electrokinetic injection during 2.0 s at 1.0 kV.
Collapse
Affiliation(s)
- Eric T da Costa
- Departamento de Química Fundamental-Instituto de Química-Universidade de São Paulo, São Paulo - SP, Brazil
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Mora MF, Stockton AM, Willis PA. Microchip capillary electrophoresis instrumentation for in situ analysis in the search for extraterrestrial life. Electrophoresis 2012; 33:2624-38. [DOI: 10.1002/elps.201200102] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
9
|
Desoubries C, Chapuis-Hugon F, Bossée A, Pichon V. Three-phase hollow fiber liquid-phase microextraction of organophosphorous nerve agent degradation products from complex samples. J Chromatogr B Analyt Technol Biomed Life Sci 2012; 900:48-58. [DOI: 10.1016/j.jchromb.2012.05.029] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2012] [Revised: 05/15/2012] [Accepted: 05/24/2012] [Indexed: 11/16/2022]
|
10
|
Zirconia coated stir bar sorptive extraction combined with large volume sample stacking capillary electrophoresis-indirect ultraviolet detection for the determination of chemical warfare agent degradation products in water samples. J Chromatogr A 2012; 1247:49-56. [DOI: 10.1016/j.chroma.2012.05.059] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2012] [Revised: 05/11/2012] [Accepted: 05/17/2012] [Indexed: 11/19/2022]
|
11
|
Analytical applications of the electrochemiluminescence of tris(2,2′-bipyridyl)ruthenium(II) coupled to capillary/microchip electrophoresis: A review. Anal Chim Acta 2011; 704:16-32. [DOI: 10.1016/j.aca.2011.07.016] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2011] [Revised: 07/09/2011] [Accepted: 07/11/2011] [Indexed: 11/24/2022]
|
12
|
AL-Othman ZA, Ali I. NANO CAPILLARY ELECTROPHORESIS IN MICROCHIPS: A NEED OF THE PRESENT CENTURY. J LIQ CHROMATOGR R T 2011. [DOI: 10.1080/10826076.2011.566031] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Zeid A. AL-Othman
- a Department of Chemistry, College of Science , King Saud University , Riyadh, Kingdom of Saudi Arabia
| | - Imran Ali
- b Department of Chemistry , Jamia Millia Islamia, (Central University) , New Delhi, India
| |
Collapse
|
13
|
Kubáň P, Seiman A, Makarõtševa N, Vaher M, Kaljurand M. In situ determination of nerve agents in various matrices by portable capillary electropherograph with contactless conductivity detection. J Chromatogr A 2011; 1218:2618-25. [DOI: 10.1016/j.chroma.2011.03.006] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2011] [Revised: 03/03/2011] [Accepted: 03/07/2011] [Indexed: 11/29/2022]
|
14
|
Aleksenko SS, Gareil P, Timerbaev AR. Analysis of degradation products of chemical warfare agents using capillary electrophoresis. Analyst 2011; 136:4103-18. [DOI: 10.1039/c1an15440k] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
15
|
Chen Q, Fung Y. Capillary electrophoresis with immobilized quantum dot fluorescence detection for rapid determination of organophosphorus pesticides in vegetables. Electrophoresis 2010; 31:3107-14. [DOI: 10.1002/elps.201000260] [Citation(s) in RCA: 71] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
16
|
Maji S, Asrey R, Kumar S, Saxena C, Kumar N, Vyas KD, Banerjee S. Polymer-coated piezoelectric quartz crystal sensor for sensing the nerve agent simulant dimethyl methylphosphonate vapor. J Appl Polym Sci 2010. [DOI: 10.1002/app.31942] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
17
|
Lieberzeit PA, Findeisen A, Mähner J, Samardzic R, Pitkänen J, Anttalainen O, Dickert F. Artificial receptor layers for detecting chemical and biological threats. ACTA ACUST UNITED AC 2010. [DOI: 10.1016/j.proeng.2010.09.127] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
18
|
Paraoxonase activity against nerve gases measured by capillary electrophoresis and characterization of human serum paraoxonase (PON1) polymorphism in the coding region (Q192R). Anal Biochem 2009; 385:94-100. [DOI: 10.1016/j.ab.2008.09.044] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2008] [Revised: 09/25/2008] [Accepted: 09/26/2008] [Indexed: 11/22/2022]
|
19
|
Llopis X, Pumera M, Alegret S, Merkoçi A. Lab-on-a-chip for ultrasensitive detection of carbofuran by enzymatic inhibition with replacement of enzyme using magnetic beads. LAB ON A CHIP 2009; 9:213-218. [PMID: 19107276 DOI: 10.1039/b816643a] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
In this paper an ultrasensitive method to determine toxicity due to pesticides in a glass lab-on-a-chip by means of enzymatic inhibition of acetylcholinesterase immobilised on magnetic beads is described. The reproducible insertion of a controlled amount of enzyme-coupled magnetic beads inside the chip channel and their immobilisation in a capture region with the aid of a magnetic field has been optimised. This procedure enables the easy renewal of the biosensing material after each determination in a highly reproducible manner. Several operational parameters such as the working potential for the selective detection of thiocholine (TCh) on a platinum disc electrode, the TCh detection reproducibility and sensitivity, the electroosmotic flow driving voltage and the inhibition time were also evaluated or optimised. The detection of carbofuran (one of the most toxic carbamate pesticides) has been achieved down to the nanomolar level.
Collapse
Affiliation(s)
- Xavier Llopis
- Grup de Sensors i Biosensors, Departament de Química, Edifici C, Universitat Autònoma de Barcelona, 08193, Cerdanyola del Vallès, Catalonia, Spain
| | | | | | | |
Collapse
|
20
|
Liu C, Mo YY, Chen ZG, Li X, Li OL, Zhou X. Dual fluorescence/contactless conductivity detection for microfluidic chip. Anal Chim Acta 2008; 621:171-7. [DOI: 10.1016/j.aca.2008.05.040] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2008] [Revised: 05/09/2008] [Accepted: 05/13/2008] [Indexed: 10/22/2022]
|
21
|
Tan HY, Loke WK, Tan YT, Nguyen NT. A lab-on-a-chip for detection of nerve agent sarin in blood. LAB ON A CHIP 2008; 8:885-91. [PMID: 18497907 DOI: 10.1039/b800438b] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Sarin (C(4)H(10)FO(2)P,O-isopropyl methylphosphonofluoridate) is a colourless, odourless and highly toxic phosphonate that acts as a cholinesterase inhibitor and disrupts neuromuscular transmission. Sarin and related phosphonates are chemical warfare agents, and there is a possibility of their application in a military or terrorist attack. This paper reports a lab-on-a-chip device for detecting a trace amount of sarin in a small volume of blood. The device should allow early detection of sarin exposure during medical triage to differentiate between those requiring medical treatment from mass psychogenic illness cases. The device is based on continuous-flow microfluidics with sequential stages for lysis of whole blood, regeneration of free nerve agent from its complex with blood cholinesterase, protein precipitation, filtration, enzyme-assisted reaction and optical detection. Whole blood was first mixed with a nerve gas regeneration agent, followed by a protein precipitation step. Subsequently, the lysed product was filtered on the chip in two steps to remove particulates and fluoride ions. The filtered blood sample was then tested for trace levels of regenerated sarin using immobilised cholinesterase on the chip. Activity of immobilised cholinesterase was monitored by the enzyme-assisted reaction of a substrate and reaction of the end-product with a chromophore. Resultant changes in chromophore-induced absorbance were recorded on the chip using a Z-shaped optical window. Loss of enzyme activity obtained prior and after passage of the treated blood sample, as shown by a decrease in recorded absorbance values, indicates the presence of either free or regenerated sarin in the blood sample. The device was fabricated in PMMA (polymethylmethacrylate) using CO(2)-laser micromachining. This paper reports the testing results of the different stages, as well as the whole device with all stages in the required assay sequence. The results demonstrate the potential use of a field-deployable hand-held device for point-of-care triage of suspected nerve agent casualties.
Collapse
Affiliation(s)
- Hsih Yin Tan
- DSO National Laboratories, 20 Science Park Drive, Singapore118230
| | | | | | | |
Collapse
|
22
|
John H, Worek F, Thiermann H. LC-MS-based procedures for monitoring of toxic organophosphorus compounds and verification of pesticide and nerve agent poisoning. Anal Bioanal Chem 2008; 391:97-116. [DOI: 10.1007/s00216-008-1925-z] [Citation(s) in RCA: 97] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2007] [Revised: 01/25/2008] [Accepted: 01/28/2008] [Indexed: 11/24/2022]
|
23
|
Kanamori-Kataoka M, Seto Y. Laboratory Identification of the Nerve Gas Hydrolysis Products Alkyl Methylphosphonic Acids and Methylphosphonic Acid, by Gas Chromatography-mass Spectrometry after tert-Butyldimethylsilylation. ACTA ACUST UNITED AC 2008. [DOI: 10.1248/jhs.54.513] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Affiliation(s)
| | - Yasuo Seto
- Fourth Chemistry Section, National Research Institute of Police Science
| |
Collapse
|
24
|
Zhang XL, Yang Q, Jiao BH, Dai J, Zhang JX, Ni WZ. Sensitive determination of pheomelanin after 5-carboxyfluorescein succinimidyl ester precapillary derivatization and micellar electrokinetic capillary chromatography with laser-induced fluorescence detection. J Chromatogr B Analyt Technol Biomed Life Sci 2008; 861:136-9. [DOI: 10.1016/j.jchromb.2007.11.031] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2007] [Revised: 11/20/2007] [Accepted: 11/23/2007] [Indexed: 11/26/2022]
|
25
|
Du Y, Wang E. Capillary electrophoresis and microchip capillary electrophoresis with electrochemical and electrochemiluminescence detection. J Sep Sci 2007; 30:875-90. [PMID: 17536733 DOI: 10.1002/jssc.200600472] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Recent advances and key strategies in capillary electrophoresis and microchip CE with electrochemical detection (ECD) and electrochemiluminescence (ECL) detection are reviewed. This article consists of four main parts: CE-ECD; microchip CE-ECD; CE-ECL; and microchip CE-ECL. It is expected that ECD and ECL will become powerful tools for CE microchip systems and will lead to the creation of truly disposable devices. The focus is on papers published in the last two years (from 2005 to 2006).
Collapse
Affiliation(s)
- Yan Du
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Graduate School of the Chinese Academy of Sciences, Changchun, Jilin, PR China
| | | |
Collapse
|
26
|
Richardson DD, Caruso JA. Derivatization of organophosphorus nerve agent degradation products for gas chromatography with ICPMS and TOF-MS detection. Anal Bioanal Chem 2007; 388:809-23. [PMID: 17356819 DOI: 10.1007/s00216-007-1164-8] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2006] [Revised: 01/24/2007] [Accepted: 01/30/2007] [Indexed: 11/30/2022]
Abstract
Separation and detection of seven V-type (venomous) and G-type (German) organophosphorus nerve agent degradation products by gas chromatography with inductively coupled plasma mass spectrometry (GC-ICPMS) is described. The nonvolatile alkyl phosphonic acid degradation products of interest included ethyl methylphosphonic acid (EMPA, VX acid), isopropyl methylphosphonic acid (IMPA, GB acid), ethyl hydrogen dimethylamidophosphate sodium salt (EDPA, GA acid), isobutyl hydrogen methylphosphonate (IBMPA, RVX acid), as well as pinacolyl methylphosphonic acid (PMPA), methylphosphonic acid (MPA), and cyclohexyl methylphosphonic acid (CMPA, GF acid). N-(tert-Butyldimethylsilyl)-N-methyltrifluroacetamide with 1% TBDMSCl was utilized to form the volatile TBDMS derivatives of the nerve agent degradation products for separation by GC. Exact mass confirmation of the formation of six of the TBDMS derivatives was obtained by GC-time of flight mass spectrometry (TOF-MS). The method developed here allowed for the separation and detection of all seven TBDMS derivatives as well as phosphate in less than ten minutes. Detection limits for the developed method were less than 5 pg with retention times and peak area precisions of less than 0.01 and 6%, respectively. This method was successfully applied to river water and soil matrices. To date this is the first work describing the analysis of chemical warfare agent (CWA) degradation products by GC-ICPMS.
Collapse
Affiliation(s)
- Douglas D Richardson
- Department of Chemistry, McMicken College of Arts and Sciences, University of Cincinnati, Cincinnati, OH 45221-0172, USA
| | | |
Collapse
|
27
|
Lagarrigue M, Bossée A, Bégos A, Varenne A, Gareil P, Bellier B. Separation and identification of isomeric acidic degradation products of organophosphorus chemical warfare agents by capillary electrophoresis-ion trap mass spectrometry. J Chromatogr A 2006; 1137:110-8. [PMID: 17081549 DOI: 10.1016/j.chroma.2006.09.089] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2006] [Revised: 09/26/2006] [Accepted: 09/29/2006] [Indexed: 11/16/2022]
Abstract
Capillary electrophoresis (CE) coupled to ion trap mass spectrometry (MS) was evaluated for the separation and identification of chemical warfare agent degradation products (alkylphosphonic acids and alkyl alkylphosphonic acids). Different analytical parameters were optimized in negative ionization mode such as electrolyte composition (15 mM CH(3)COONH(4), pH 8.8), sheath liquid composition (MeOH/H(2)O/NH(3), 75:25:2, v/v/v), nebulization and ion trapping conditions. A standard mixture of five alkylphosphonic (di)acids and five alkyl alkylphosphonic (mono)acids containing isomeric compounds was used in order to evaluate CE selectivity and MS identification capability. The obtained electropherograms revealed that CE selectivity was very limited in the case of alkyl alkylphosphonic acid positional isomers, whereas isomeric isopropylphosphonic and propylphosphonic acids were baseline-separated. CE-MS-MS experiments provided an unambiguous identification of each isomeric co-migrating alkyl alkylphosphonic acids thanks to the presence of specific fragment ions. On the other hand, CE separation was mandatory for the identification of isomeric alkylphosphonic acids, which led to the same fragment ion and could not be differentiated by MS-MS. The developed method was applied to the analysis of soil extracts spiked with the analytes (before or after extraction treatment) and appeared to be very promising since resolution and sensitivity were similar to those observed in deionized water. Especially, analytes were detected and identified in soil extract spiked at 5 microg mL(-1) with each compound before extraction treatment.
Collapse
Affiliation(s)
- Mélanie Lagarrigue
- Département Analyse Chimique, Centre d'Etudes du Bouchet DGA, 5 rue Lavoisier, BP 3, 91710 Vert-le-Petit, France
| | | | | | | | | | | |
Collapse
|
28
|
New Hydrodynamic Electrochemical Arrangement for Cadmium Ions Detection Using Thick-Film Chemical Sensor Electrodes. SENSORS 2006. [DOI: 10.3390/s6111498] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|