1
|
Hanson EK, Foster SW, Piccolo C, Grinias JP. Considerations for Method Development and Method Translation in Capillary Liquid Chromatography: A Tutorial. JOURNAL OF CHROMATOGRAPHY OPEN 2024; 6:100190. [PMID: 40092551 PMCID: PMC11905334 DOI: 10.1016/j.jcoa.2024.100190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/19/2025]
Abstract
HPLC continues to be one of the most widely used measurement techniques for chemical analysis. Capillary LC, which utilizes narrow diameter columns operated at lower flow rates than analytical-scale LC, continues to gain adoption based on its reduced mobile phase consumption and increased sensitivity when coupled to MS detection. This tutorial offers practical insights into the most critical aspects of translating analytical-scale separations to the capillary scale. The selection of pumping systems, detectors, and the potential for performance loss due to extra-column effects are examined within the context of separations using columns with inner diameters ≤ 0.3 mm. Column choices within this diameter range are also detailed, both in terms of stationary phase support options and general commercial availability. The impact of these various factors on the effective development/translation of LC methods down to flow rates under 10 μL/min is described to provide readers with a basis for implementing these strategies within their own analytical workflows.
Collapse
Affiliation(s)
- Eliza K. Hanson
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028
| | - Samuel W. Foster
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028
| | - Christopher Piccolo
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028
| | - James P. Grinias
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028
| |
Collapse
|
2
|
Anderson BG, Hancock TA, Kennedy RT. Preparation of high-efficiency HILIC capillary columns utilizing slurry packing at 2100 bar. J Chromatogr A 2024; 1722:464856. [PMID: 38579610 DOI: 10.1016/j.chroma.2024.464856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 03/26/2024] [Accepted: 03/29/2024] [Indexed: 04/07/2024]
Abstract
Complex mixture analysis requires high-efficiency chromatography columns. Although reversed phase liquid chromatography (RPLC) is the dominant approach for such mixtures, hydrophilic interaction liquid chromatography (HILIC) is an important complement to RPLC by enabling the separation of polar compounds. Chromatography theory predicts that small particles and long columns will yield high efficiency; however, little work has been done to prepare HILIC columns longer than 25 cm packed with sub-2 μm particles. In this work, we tested the slurry packing of 75 cm long HILIC columns with 1.7 μm bridged-ethyl-hybrid amide HILIC particles at 2,100 bar (30,000 PSI). Acetonitrile, methanol, acetone, and water were tested as slurry solvents, with acetonitrile providing the best columns. Slurry concentrations of 50-200 mg/mL were assessed, and while 50-150 mg/mL provided comparable results, the 150 mg/mL columns provided the shortest packing times (9 min). Columns prepared using 150 mg/mL slurries in acetonitrile yielded a reduced minimum plate height (hmin) of 3.3 and an efficiency of 120,000 theoretical plates for acenaphthene, an unretained solute. Para-toluenesulfonic acid produced the lowest hmin of 1.9 and the highest efficiency of 210,000 theoretical plates. These results identify conditions for producing high-efficiency HILIC columns with potential applications to complex mixture analysis.
Collapse
Affiliation(s)
- Brady G Anderson
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, United States
| | - Tate A Hancock
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, United States
| | - Robert T Kennedy
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, United States; Department of Pharmacology, University of Michigan, Ann Arbor, MI 48109, United States.
| |
Collapse
|
3
|
Lenčo J, Jadeja S, Naplekov DK, Krokhin OV, Khalikova MA, Chocholouš P, Urban J, Broeckhoven K, Nováková L, Švec F. Reversed-Phase Liquid Chromatography of Peptides for Bottom-Up Proteomics: A Tutorial. J Proteome Res 2022; 21:2846-2892. [PMID: 36355445 DOI: 10.1021/acs.jproteome.2c00407] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The performance of the current bottom-up liquid chromatography hyphenated with mass spectrometry (LC-MS) analyses has undoubtedly been fueled by spectacular progress in mass spectrometry. It is thus not surprising that the MS instrument attracts the most attention during LC-MS method development, whereas optimizing conditions for peptide separation using reversed-phase liquid chromatography (RPLC) remains somewhat in its shadow. Consequently, the wisdom of the fundaments of chromatography is slowly vanishing from some laboratories. However, the full potential of advanced MS instruments cannot be achieved without highly efficient RPLC. This is impossible to attain without understanding fundamental processes in the chromatographic system and the properties of peptides important for their chromatographic behavior. We wrote this tutorial intending to give practitioners an overview of critical aspects of peptide separation using RPLC to facilitate setting the LC parameters so that they can leverage the full capabilities of their MS instruments. After briefly introducing the gradient separation of peptides, we discuss their properties that affect the quality of LC-MS chromatograms the most. Next, we address the in-column and extra-column broadening. The last section is devoted to key parameters of LC-MS methods. We also extracted trends in practice from recent bottom-up proteomics studies and correlated them with the current knowledge on peptide RPLC separation.
Collapse
Affiliation(s)
- Juraj Lenčo
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Siddharth Jadeja
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Denis K Naplekov
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Oleg V Krokhin
- Department of Internal Medicine, Manitoba Centre for Proteomics and Systems Biology, University of Manitoba, 799 JBRC, 715 McDermot Avenue, WinnipegR3E 3P4, Manitoba, Canada
| | - Maria A Khalikova
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Petr Chocholouš
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Jiří Urban
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00Brno, Czech Republic
| | - Ken Broeckhoven
- Department of Chemical Engineering (CHIS), Faculty of Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050Brussel, Belgium
| | - Lucie Nováková
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - František Švec
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| |
Collapse
|
4
|
Roca LS, Adamopoulou T, Nawada SH, Schoenmakers PJ. Introduction of Octadecyl-Bonded Porous Particles in 3D-Printed Transparent Housings with Multiple Outlets. Chromatographia 2022; 85:783-793. [PMID: 35965655 PMCID: PMC9363280 DOI: 10.1007/s10337-022-04156-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 03/29/2022] [Accepted: 03/31/2022] [Indexed: 11/03/2022]
Abstract
AbstractMicrofluidic devices for comprehensive three-dimensional spatial liquid chromatography will ultimately require a body of stationary phase with multiple in- and outlets. In the present work, 3D printing with a transparent polymer resin was used to create a simplified device that can be seen as a unit cell for an eventual three-dimensional separation system. Complete packing of the device with 5-μm C18 particles was achieved, with reasonable permeability. The packing process could be elegantly monitored from the pressure profile, which implies that optical transparency may not be required for future devices. The effluent flow was different for each of the four outlets of the device, but all flows were highly repeatable, suggesting that correction for flow-rate variations is possible. The investigation into flow patterns through the device was supported by computational-fluid-dynamics simulations. A proof-of-principle separation of four standard peptides is described, with mass-spectrometric detection for each of the four channels separately.
Collapse
|
5
|
Dembek M, Szumski M, Bocian S, Buszewski B. Optimization of the packing process of microcolumns with the embedded phosphodiester stationary phases. J Sep Sci 2022; 45:3310-3318. [PMID: 35665599 DOI: 10.1002/jssc.202200389] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 05/31/2022] [Accepted: 06/01/2022] [Indexed: 11/07/2022]
Abstract
The development of new home-made stationary phases involves their packaging procedure and is crucial to obtain satisfactory working parameters. The parameter that illustrates the quality of the packed bed is its efficiency measured as the height equivalent to the theoretical plate. According to the Van Deemetr's equation, it depends on three factors, but only one of them, eddy diffusion, does not depend on the linear flow velocity. Therefore, in order to obtain it as low as possible, it is necessary to focus on a good filling of the column. Among many parameters affecting the quality of column packing, in our work we have focused on the choice of slurry solvent. Novel stationary phases with an embedded phosphodiester group were investigated. The suspensions in 16 solvents and solvent mixtures were studied for their stability, aggregation, sedimentation and viscosity comparison. The efficiency of the packed microcolumns and its comparison was determined by chromatographic analyses using a polar (thymidine) and a non-polar compound (naphthalene). The results obtained led to the conclusion that for these stationary phases, the best slurry solvent is the one that aggregates the phase while maintaining stability and having high viscosity. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Mikołaj Dembek
- Chair of Environmental Chemistry and Bioanalysis, Faculty of Chemistry
| | - Michał Szumski
- Centre for Modern Interdisciplinary Technologies, Nicolaus Copernicus University
| | - Szymon Bocian
- Chair of Environmental Chemistry and Bioanalysis, Faculty of Chemistry
| | - Bogusław Buszewski
- Chair of Environmental Chemistry and Bioanalysis, Faculty of Chemistry.,Centre for Modern Interdisciplinary Technologies, Nicolaus Copernicus University
| |
Collapse
|
6
|
Sorensen MJ, Kennedy RT. Capillary ultrahigh-pressure liquid chromatography-mass spectrometry for fast and high resolution metabolomics separations. J Chromatogr A 2020; 1635:461706. [PMID: 33229007 DOI: 10.1016/j.chroma.2020.461706] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 11/04/2020] [Accepted: 11/09/2020] [Indexed: 12/15/2022]
Abstract
LC-MS is an important tool for metabolomics due its high sensitivity and broad metabolite coverage. The goal of improving resolution and decreasing analysis time in HPLC has led to the use of 5 - 15 cm long columns packed with 1.7 - 1.9 µm particles requiring pressures of 8 - 12 kpsi. We report on the potential for capillary LC-MS based metabolomics utilizing porous C18 particles down to 1.1 µm diameter and columns up to 50 cm long with an operating pressure of 35 kpsi. Our experiments show that it is possible to pack columns with 1.1 µm porous particles to provide predicted improvements in separation time and efficiency. Using kinetic plots to guide the choice of column length and particle size, we packed 50 cm long columns with 1.7 µm particles and 20 cm long columns with 1.1 µm particles, which should produce equivalent performance in shorter times. Columns were tested by performing isocratic and gradient LC-MS analyses of small molecule metabolites and extracts from plasma. These columns provided approximately 100,000 theoretical plates for metabolite standards and peak capacities over 500 in 100 min for a complex plasma extract with robust interfacing to MS. To generate a given peak capacity, the 1.1 µm particles in 20 cm columns required roughly 75% of the time as 1.7 µm particles in 50 cm columns with both operated at 35 kpsi. The 1.1 µm particle packed columns generated a given peak capacity nearly 3 times faster than 1.7 µm particles in 15 cm columns operated at ~10 kpsi. This latter condition represents commercial state of the art for capillary LC. To consider practical benefits for metabolomics, the effect of different LC-MS variables on mass spectral feature detection was evaluated. Lower flow rates (down to 700 nL/min) and larger injection volumes (up to 1 µL) increased the features detected with modest loss in separation performance. The results demonstrate the potential for fast and high resolution separations for metabolomics using 1.1 µm particles operated at 35 kpsi for capillary LC-MS.
Collapse
Affiliation(s)
- Matthew J Sorensen
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA
| | - Robert T Kennedy
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA; Department of Pharmacology, University of Michigan, Ann Arbor, MI 48109, USA.
| |
Collapse
|
7
|
Gritti F, Hochstrasser J, Svidrytski A, Hlushkou D, Tallarek U. Morphology-transport relationships in liquid chromatography: Application to method development in size exclusion chromatography. J Chromatogr A 2020; 1620:460991. [DOI: 10.1016/j.chroma.2020.460991] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Revised: 02/13/2020] [Accepted: 02/20/2020] [Indexed: 12/14/2022]
|
8
|
Sorensen MJ, Miller KE, Jorgenson JW, Kennedy RT. Ultrahigh-Performance capillary liquid chromatography-mass spectrometry at 35 kpsi for separation of lipids. J Chromatogr A 2020; 1611:460575. [PMID: 31607445 PMCID: PMC6980658 DOI: 10.1016/j.chroma.2019.460575] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 09/25/2019] [Accepted: 09/26/2019] [Indexed: 12/24/2022]
Abstract
Improvements in sample preparation, separation, and mass spectrometry continue to expand the coverage in LC-MS based lipidomics. While longer columns packed with smaller particles in theory give higher separation performance compared to shorter columns, the implementation of this technology above commercial limits has been sparse due to difficulties in packing long columns and successfully operating instruments at ultrahigh pressures. In this work, a liquid chromatograph that operates up to 35 kpsi was investigated for the separation and identification of lipid species from human plasma. Capillary columns between 15-50 cm long were packed with 1.7 µm BEH C18 particles and evaluated for their ability to separate lipid isomers and complex lipid extracts from human plasma. Putative lipid class identifications were assigned using accurate mass and relative retention time data of the eluting peaks. Our findings indicate that longer columns packed and operated at 35 kpsi outperform shorter columns packed and run at lower pressures in terms of peak capacity and numbers of features identified. Packing columns with relatively high concentration slurries (200 mg/mL) while sonicating the column resulted in 6-34% increase in peak capacity for 50 cm columns compared to lower slurry concentrations and no sonication. For a given analysis time, 50 cm long columns operated at 35 kpsi provided a 20-95% increase in chromatographic peak capacity compared with 15 cm columns operated at 15 kpsi. Analysis times up to 4 h were evaluated, generating peak capacities up to 410 ± 5 (n = 3, measured at 4σ) and identifying 480 ± 85 lipids (n = 2). Importantly, the results also show a correlation between the peak capacity and the number of lipids identified from a human plasma extract. This correlation indicates that ionization suppression is a limiting factor in obtaining sufficient signal for identification by mass spectrometry. The result also shows that the higher resolution obtained by shallow gradients overcomes possible signal reduction due to broader, more dilute peaks in long gradients for improving detection of lipids in LC-MS. Lastly, longer columns operated at shallow gradients allowed for the best separation of both regional and geometrical isomers. These results demonstrate a system that enables the advantages of using longer columns packed and run at ultrahigh pressure for improving lipid separations and lipidome coverage.
Collapse
Affiliation(s)
- Matthew J Sorensen
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA
| | - Kelsey E Miller
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
| | - James W Jorgenson
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
| | - Robert T Kennedy
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA; Department of Pharmacology, University of Michigan, Ann Arbor, MI 48109, USA.
| |
Collapse
|
9
|
Abstract
Continued improvements in HPLC have led to faster and more efficient separations than previously possible. One important aspect of these improvements has been the increase in instrument operating pressure and the advent of ultrahigh pressure LC (UHPLC). Commercial instrumentation is now capable of up to ~20 kpsi, allowing fast and efficient separations with 5-15 cm columns packed with sub-2 μm particles. Home-built instruments have demonstrated the benefits of even further increases in instrument pressure. The focus of this review is on recent advancements and applications in liquid chromatography above 20 kpsi. We outline the theory and advantages of higher pressure and discuss instrument hardware and design capable of withstanding 20 kpsi or greater. We also overview column packing procedures and stationary phase considerations for HPLC above 20 kpsi, and lastly highlight a few recent applicatioob pressure instruments for the analysis of complex mixtures.
Collapse
Affiliation(s)
- Matthew J Sorensen
- Department of Chemistry, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Brady G Anderson
- Department of Chemistry, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Robert T Kennedy
- Department of Chemistry, University of Michigan, Ann Arbor, MI, 48109, USA.,Department of Pharmacology, University of Michigan, Ann Arbor, MI, 48109, USA
| |
Collapse
|
10
|
Schure MR, Maier RS. Ellipsoidal particles for liquid chromatography: Fluid mechanics, efficiency and wall effects. J Chromatogr A 2018; 1580:30-48. [DOI: 10.1016/j.chroma.2018.09.051] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2018] [Revised: 09/16/2018] [Accepted: 09/24/2018] [Indexed: 10/28/2022]
|
11
|
Dores-Sousa JL, De Vos J, Eeltink S. Resolving power in liquid chromatography: A trade-off between efficiency and analysis time. J Sep Sci 2018; 42:38-50. [DOI: 10.1002/jssc.201800891] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 09/13/2018] [Accepted: 09/13/2018] [Indexed: 01/28/2023]
Affiliation(s)
- José Luís Dores-Sousa
- Department of Chemical Engineering; Vrije Universiteit Brussel (VUB); Brussels Belgium
| | - Jelle De Vos
- Department of Chemical Engineering; Vrije Universiteit Brussel (VUB); Brussels Belgium
| | - Sebastiaan Eeltink
- Department of Chemical Engineering; Vrije Universiteit Brussel (VUB); Brussels Belgium
| |
Collapse
|