1
|
Moussa A, Huygens B, Venditti C, Adrover A, Desmet G. On the contribution of the top and bottom walls in micro-pillar array columns and related high-aspect ratio chromatography systems. J Chromatogr A 2024; 1720:464825. [PMID: 38507870 DOI: 10.1016/j.chroma.2024.464825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 03/15/2024] [Accepted: 03/16/2024] [Indexed: 03/22/2024]
Abstract
We report on a steady-state based, and hence highly accurate numerical modelling study of the effect of the top and bottom wall in the current generation of micro-pillar array columns. These have a mesoporous retention layer that not only covers the pillar walls but also the bottom wall. Our results show that the performance of these columns can in general not be improved by also covering the top wall with the same layer, despite the increased column symmetry this approach would offer. The reason for this is that the local species retardation caused by a retentive layer is much stronger than the pure flow arresting effect of an uncovered wall. At least, this has a crucial impact in high aspect-ratio systems such as micro-pillar array columns because these require a small inter-pillar distance to promote mass transfer together with a large channel depth to enable a sufficiently high flow rate. On the other hand, a notable improvement could be made if micro-pillar array would be produced without having a retentive layer at the bottom. At Péclet number Pe = 50 and aspect ratio AR = 5 for flow-channels, this gain amounts up to about 4.5 h-units at a zone retention factor k'' = 2 and 1.75 h-units at k'' = 16 (gain scales almost linearly with Pe). To verify these results, we also considered another high aspect-ratio system with a simplified geometry: the open-tubular channel with a flat-rectangular cross-section. This led to very similar observations, thus confirming the findings for the micro-pillar array. The results produced in the present study also allow us to conclude that the classic modelling paradigm adopted in chromatography, which is based on the independency and hence additivity of the hCm- and hCs-contributions, can lead to large modelling errors in chromatographic systems with a high aspect-ratio, even when their geometry is so simple as that of a straight open-tubular channel with constant cross-section. Indeed, when both zones are treated independently, the analysis misses how the vertical diffusion through the retentive layer helps suppressing the vertical gradients in the mobile zone. The diffusion through this layer occurs in a ratio of k''Ds/Dm (Dm being the diffusion coefficient in mobile phase zone and Ds being the diffusion coefficient in stationary phase zone), such that at high retention factors this diffusion contribution even becomes the dominant one.
Collapse
Affiliation(s)
- Ali Moussa
- Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium
| | - Bram Huygens
- Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium
| | - Claudia Venditti
- Dipartimento di Ingegneria Chimica Materiali Ambiente, Sapienza Università di Roma, Italy
| | - Alessandra Adrover
- Dipartimento di Ingegneria Chimica Materiali Ambiente, Sapienza Università di Roma, Italy
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium.
| |
Collapse
|
2
|
Vankeerberghen B, Op de Beeck J, Desmet G. Column-Only Band Broadening in a Porous Shell Radially Elongated Pillar Array Column. Anal Chem 2024; 96:3618-3626. [PMID: 38350649 DOI: 10.1021/acs.analchem.3c05756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2024]
Abstract
In the quest for better performing separation media for liquid chromatography, micropillar array columns have received great interest over the past years. While previous research was mainly focused around micropillar array columns (μPACs) filled with cylindrical pillars, this contribution discusses μPACs with rectangular pillars, which, for the first time, have been anodized and hence carry a mesoporous shell. We report on a series of on-chip measurements of the band broadening and flow permeability in a μPAC with very wide radially elongated pillars (3·75 μm) and with an interpillar distance (2 μm) between that of the first (2.5 μm) and second generation (1.25 μm) of cylindrical μPACs. Because of the extreme flow path tortuosity, this type of μPAC can produce very large plate numbers over a short distance. Despite the relatively large interpillar distance, we obtain Hmin = 0.26 μm for a nearly unretained component (phase retention factor, k' ≈ 0.24) and Hmin = 0.79 μm for a retained component with k' ≈ 3. The kinetic performance in terms of separation impedance (Ei = 19) is considerably improved compared to cylindrical pillar μPACs (Ei in range 40-50) and is in excellent agreement with the theoretical value for an open tubular channel with a rectangular cross-section (Ei = 18). This shows that rectangular μPACs can be represented as a parallel bundle of interconnected open-tubular channels.
Collapse
Affiliation(s)
- Bert Vankeerberghen
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium
| | - Jeff Op de Beeck
- Thermo Fisher Scientific, Technologiepark-Zwijnaarde 82, 9052 Gent, Belgium
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium
| |
Collapse
|
3
|
Liang Y, Zhang L, Zhang Y. Chromatographic separation of peptides and proteins for characterization of proteomes. Chem Commun (Camb) 2023; 59:270-281. [PMID: 36504223 DOI: 10.1039/d2cc05568f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
Characterization of proteomes aims to comprehensively characterize proteins in cells or tissues via two main strategies: (1) bottom-up strategy based on the separation and identification of enzymatic peptides; (2) top-down strategy based on the separation and identification of intact proteins. However, it is challenged by the high complexity of proteomes. Consequently, the improvements in peptide and protein separation technologies for simplifying the sample should be critical. In this feature article, separation columns for peptide and protein separation were introduced, and peptide separation technologies for bottom-up proteomic analysis as well as protein separation technologies for top-down proteomic analysis were summarized. The achievement, recent development, limitation and future trends are discussed. Besides, the outlook on challenges and future directions of chromatographic separation in the field of proteomics was also presented.
Collapse
Affiliation(s)
- Yu Liang
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China.
| | - Lihua Zhang
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China.
| | - Yukui Zhang
- CAS Key Lab of Separation Sciences for Analytical Chemistry, National Chromatographic Research and Analysis Center, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China.
| |
Collapse
|
4
|
Matheuse F, Vanmol K, Van Erps J, De Malsche W, Ottevaere H, Desmet G. On the potential use of two-photon polymerization to 3D print chromatographic packed bed supports. J Chromatogr A 2021; 1663:462763. [PMID: 34968955 DOI: 10.1016/j.chroma.2021.462763] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Accepted: 12/16/2021] [Indexed: 12/20/2022]
Abstract
The continuous quest for chromatographic supports offering kinetic performance properties superior to that of the packed bed of spheres has pushed the field to consider alternative formats such as for example monolithic and pillar array columns. This quest seems bound to culminate in the use of 3D printing technology, as this intrinsically offers the possibility to produce supports with a perfect uniformity and with a size and shape that is fully optimized for the chromatographic separation process. However, to be competitive with the current state-of-the-art, structures with sub-micron feature sizes are required. The present contribution therefore investigates the use of the 3D printing technology with the highest possible resolution available today, i.e., two-photon polymerization (2PP). It is shown that 2PP printing is capable of achieving the required ≤ 1 µm printing resolution. Depending on the laser scan speed, the lower limit through-pore size for a tetrahedral skeleton monolith with a theoretical 80% external porosity was found to be at 800 nm, when printing at a scan speed of 50 mm/s with a laser power of 10%. For a scan speed of 10 mm/s, the minimal through-pore size dropped to 500 nm. However, this very high resolution comes at the cost of excessively long printing times. The total printing time for a column volume equivalent to that of a typical nano-LC column (75 µm i.d. cylindrical tube with length L = 15 cm) has been determined to correspond to 330 and 470 h for the 50 mm/s and the 10 mm/s scan speed respectively. Other issues remaining to be solved are the need to clad the printed skeleton with a suitable mesoporous layer for chromatographic retention and the need to add a top-wall to the printed channels after the removal of the non-polymerized resin. It is therefore concluded that 2PP printing is not ready yet to replace the existing column fabrication methods.
Collapse
Affiliation(s)
- Fréderick Matheuse
- Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium
| | - Koen Vanmol
- Department of Applied Physics and Photonics, Vrije Universiteit Brussel and Flanders Make, Brussels, Belgium
| | - Jürgen Van Erps
- Department of Applied Physics and Photonics, Vrije Universiteit Brussel and Flanders Make, Brussels, Belgium
| | - Wim De Malsche
- Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium
| | - Heidi Ottevaere
- Department of Applied Physics and Photonics, Vrije Universiteit Brussel and Flanders Make, Brussels, Belgium
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Brussels, Belgium.
| |
Collapse
|
5
|
Naghdi E, De Malsche W. Overloading behavior of fenoprofen and naproxen as two model compounds on a non-porous silicon pillar array column. J Chromatogr A 2021; 1651:462332. [PMID: 34153737 DOI: 10.1016/j.chroma.2021.462332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 05/30/2021] [Accepted: 06/06/2021] [Indexed: 11/25/2022]
Abstract
In this study, the adsorption behavior of naproxen and fenoprofen as two model compounds on a non-porous pillar array column (NPAC) was investigated under reverse phase liquid chromatography conditions. Band profiles of both analytes were recorded in overloaded concentrations using 30% methanol/water (v/v) as the mobile phase. Breakthrough experiments under the same chromatographic condition were carried out to measure the adsorption isotherms. Single-component adsorption isotherm data were acquired by frontal analysis for each analyte. The isotherms were found to be concave upward and downward for naproxen and fenoprofen, respectively. To find the best agreement between the experimental data points and the adsorption isotherm models, the obtained isotherms were modeled using several isotherm models. The Langmuir-Freundlich and anti-Langmuir models provided the best fitting for fenoprofen and naproxen, respectively. The solute and stationary phase properties determine the appropriate model. Adsorbate-adsorbate interaction is important in the case of naproxen, while the adsorbate- adsorbent (stationary phase) plays the main role in retention of fenoprofen on the NPAC. The validity of the selected isotherm models were checked by comparing calculated and experimental band profiles and plate heights. An excellent agreement was observed for the whole concentration range of both analytes, which confirmed the accuracy of the selected models.
Collapse
Affiliation(s)
- Elahe Naghdi
- µFlow group, Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium.; Faculty of Chemistry, Shahid Beheshti University, G.C., Tehran, I.R., Iran
| | - Wim De Malsche
- µFlow group, Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium..
| |
Collapse
|
6
|
Abstract
Nano liquid chromatography (nanoLC), with columns having an inner diameter (ID) of ≤100 μm, can provide enhanced sensitivity and enable analysis of limited samples.
Collapse
Affiliation(s)
- Steven Ray Wilson
- Department of Chemistry
- University of Oslo
- Oslo
- Norway
- Hybrid Technology Hub-Centre of Excellence
| | | | | |
Collapse
|