Keskin Perk FFN, Taneri S, Tanriverdi C, Haciagaoglu S, Karaca ZY, Kilic A. Increasing depth of focus with allogeneic presbyopic inlays: 3-year results.
J Cataract Refract Surg 2023;
49:1005-1010. [PMID:
37487178 DOI:
10.1097/j.jcrs.0000000000001270]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Accepted: 07/19/2023] [Indexed: 07/26/2023]
Abstract
PURPOSE
To demonstrate the safety and efficacy of allogenic corneal inlays designed to increase the depth of focus (DoF) in treated eyes.
SETTINGS
Medipol University Hospital, Istanbul, Turkey.
DESIGN
Prospective case series.
METHODS
This study includes 50 eyes of 25 patients with a follow-up of 3 years. Emmetropic patients with presbyopia had implantation of allogenic corneal inlays in the nondominant eye. The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and uncorrected near visual acuity (UNVA) were evaluated in all eyes. A subjective visual acuity test system (Multifocal Lens Analyzer 3.0 application) was used to analyze the DoF by measuring the defocus curves.
RESULTS
No significant difference between the treated and fellow eyes in UDVA and CDVA was found, whereas UNVA was significantly better in the treated eyes ( P = .20, P = .07, P < .01, respectively). Comparing to the preoperative CDVA, there was a 1-line decrease in CDVA in 6 (%24) patients. The mean defocus curves reveal a DoF of 1.1 diopters (D) for the untreated eye at the logMAR = 0.2 threshold. By contrast, the mean DoF of the treated eye and binocularly was 2.8 D. The areas under the curve were significantly better in the near, intermediate, and total distances in the treated eyes, whereas it was better for the far distances in the untreated eyes. All values were significant ( P = .023 total, P < .01 others).
CONCLUSIONS
Allogenic presbyopic inlay implantation may be safe and provided a clinically and statistically significant increase in the DoF leading to good far, intermediate, and near-visual acuity in emmetropic presbyopic patients.