1
|
Gao J, Lai Z, Hu Y, Yang X. Translation and validation of the 8-item contact lens dry eye questionnaire (CLDEQ-8) among Chinese soft contact lens wearers. Cont Lens Anterior Eye 2025; 48:102366. [PMID: 39799006 DOI: 10.1016/j.clae.2024.102366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2024] [Revised: 12/31/2024] [Accepted: 12/31/2024] [Indexed: 01/15/2025]
Abstract
PURPOSE To develop a Chinese version of the 8-item Contact Lens Dry Eye Questionnaire (CLDEQ-8) with cross-cultural adaption and clinical validation among soft contact lens wearers (SCL) in China. METHODS The translation and adaptation of the Chinese CLDEQ-8 (C-CLDEQ-8) followed a rigorous methodological process based on cross-cultural research guidelines consisting of three main phases: 1) forward and backward translation of original CLDEQ-8 into Chinese, 2) cross-cultural adaptation performed by medical advising committee, and 3) clinical validation and repeatability test of the translated questionnaire on Chinese SCL wearers. Rasch analysis was also performed to investigate the psychometric properties of C-CLDEQ-8. RESULTS 134 experienced SCL wearers aged 18-45 completed the C-CLDEQ-8. C-CLDEQ-8 score was linearly related to the overall opinion of SCLs (beta = 2.16, p = 0.002), gestalt eye dryness response (beta = 2.90, p < 0.001), and sensitivity response (beta = 1.83, p = 0.001). The questionnaire showed excellent test-retest repeatability with an intra-class correlation coefficient (ICC) of 0.95 and great internal consistency with a Cronbach's alpha of 0.83. The corrected index of homogeneity for each item was more significant than 0.5. In Rasch analysis, the infit and outfit values for eight items were all within 0.6-1.4, suggesting a good fit for the Rasch model. Martin-Löf test result indicated that the Rasch model was unidimensional (p = 1.0). Item characteristics curves suggested combining categories 3-4 and 5-6 in item 5 of C-CLDEQ-8. CONCLUSIONS This study produced a Chinese version of CLDEQ-8 with great validity and reliability and proved capable of evaluating SCL-related symptoms.
Collapse
Affiliation(s)
- Jiajia Gao
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China
| | - Zhipeng Lai
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China
| | - Yin Hu
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China
| | - Xiao Yang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China.
| |
Collapse
|
2
|
Guthrie SE, Luensmann D, Schulze MM, Woods J, Jones L. Investigation of Delefilcon A Contact Lenses for Symptomatic Daily Disposable Contact Lens Wearers with Dry Eye Disease: A Prospective Comparative Study. Clin Ophthalmol 2024; 18:2999-3008. [PMID: 39463852 PMCID: PMC11512522 DOI: 10.2147/opth.s482568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2024] [Accepted: 10/04/2024] [Indexed: 10/29/2024] Open
Abstract
Purpose This prospective comparative study aimed to assess the effects on contact lens comfort, dryness, and wear time when symptomatic daily disposable (DD) contact lens (CL) wearers were refit with delefilcon A (DT1) lenses. Patients and Methods Thirty five symptomatic DD CL wearers with dry eye disease as determined according to the TFOS DEWS 2 guidelines, were enrolled and completed the study. Participants wore their habitual DD CLs during an initial assessment and were subsequently refit with DT1 for 1 month. Participants were masked to the study lens type. Subjective ratings of end-of-day comfort and dryness, average wear time, and comfortable wear time were evaluated as primary endpoints. Results Of the 35 participants, two participants were classified as aqueous deficient dry eye, while the remaining participants exhibited symptoms primarily due to evaporative causes. The median CLDEQ-8 score for dryness significantly improved from 17 (fair) with habitual lenses to 13 (good) with DT1 lenses (p < 0.01). Participants reported significantly better end-of-day comfort (p = 0.01) and less end-of-day dryness (p = 0.01) with DT1 compared to their habitual DD lenses. The comfortable wear time was significantly longer with DT1 (8.5 ± 4.1 hours) compared to habitual DD lenses (6.7 ± 3.2 hours) (p = 0.04). No significant differences were observed in vision ratings (p = 0.07). Conclusion Refitting symptomatic DD CL wearers with DT1 resulted in improved end-of-day comfort, reduced end-of-day dryness, and extended comfortable wear time compared to their habitual lenses. These findings suggest that DT1 may offer benefits for symptomatic DD wearers with dry eye disease.
Collapse
Affiliation(s)
- Sarah E Guthrie
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada
| | - Doerte Luensmann
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada
| | - Marc-Matthias Schulze
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada
| | - Jill Woods
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada
| |
Collapse
|
3
|
Costa D, De Matteis V, Treso F, Montani G, Martino M, Rinaldi R, Corrado M, Cascione M. Impact of the physical properties of contact lens materials on the discomfort: role of the coefficient of friction. Colloids Surf B Biointerfaces 2024; 233:113630. [PMID: 37956592 DOI: 10.1016/j.colsurfb.2023.113630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/31/2023] [Accepted: 11/01/2023] [Indexed: 11/15/2023]
Abstract
Contact Lens Discomfort (CLD) is the main cause in contact lens (CLs) discontinuation, referred in literature as drop-out phenomenon. Despite such evidence was reported in several clinical studies, a relationship between physico-chemical properties of CLs and CLD is not still totally understood. In this regard, the friction of CLs surfaces seems to be related to discomfort feeling events, probably due to an alteration of the lubricate function of the tear film after the CL placement inside the ocular environment. In the last years, many studies have been finalized to the friction measurements of CLs surface, finding conflicting data due to a lack in standardized protocol. The aim of this review is primarily to show evident relationships between CLs surface properties (i.e. wettability, tear evaporation, tear film quality, etc.) and the coefficient of friction (CoF), resulting therefore the most relevant physical quantity in the CLs characterization. In addition, we reported the most recent studies in CLs tribology, which highlight that the introduction of a standard protocol in CoF measurements is necessary to obtain reproducible results, considering the aim to evaluate in a more precise way the relationship between this material surface property and comfort in CLs users.
Collapse
Affiliation(s)
- D Costa
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy
| | - V De Matteis
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy.
| | - F Treso
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - G Montani
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - M Martino
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - R Rinaldi
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy
| | - M Corrado
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy
| | - M Cascione
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy.
| |
Collapse
|
4
|
Yokoi N, Furusawa Y, Kato H, Kusada N, Sotozono C, Eftimov P, Georgiev GA. Characteristics of Pre-Lens Tear Film Behavior in Eyes Wearing Delefilcon A Silicone Hydrogel Water Gradient Contact Lenses. Diagnostics (Basel) 2023; 13:3642. [PMID: 38132226 PMCID: PMC10742534 DOI: 10.3390/diagnostics13243642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 11/21/2023] [Accepted: 12/06/2023] [Indexed: 12/23/2023] Open
Abstract
The pre-lens tear film (PLTF) over (i) delefilcon A silicone hydrogel water gradient (WG; 33-80% from core to surface) contact lenses (CLs) (SHWG-CLs) and (ii) subjects' own non-WG soft CLs (SCLs) (SO-SCLs) was studied in 30 eyes of 30 subjects to assess the hypothesized PLTF stabilization over SHWG-CLs. In both eyes, delefilcon A SHWG-CLs (DAILIES TOTAL1®; Alcon, Fort Worth, TX, USA) or SO-SCLs were worn. After 15 min of wearing each lens, the tear meniscus radius (TMR, mm), lipid-layer interference grade (IG) and spread grade (SG), and non-invasive breakup time (NIBUT, seconds) were evaluated and compared between the SHWG-CLs and the SO-SCLs. The comparison between the SHWG-CL and SO-SCL groups (SHWG-CL and SO-SCL, mean ± SD) revealed that TMRs temporarily decreased and reached a plateau value after 15 min (0.21 ± 0.06; 0.21 ± 0.06) compared to the value prior to CL insertion (0.24 ± 0.08; 0.25 ± 0.08), with no significant difference between the two groups. The NIBUT, IG, and SG values after 15 min of wearing the CLs were (9.7 ± 3.7; 4.7 ± 4.2), (1.0 ± 0.2; 1.8 ± 1.0), and (1.1 ± 0.4; 1.9 ± 1.5), respectively, and all values were significantly better in the SHWG-CL group (p < 0.0001, p = 0.0039, and p < 0.0001, respectively). We found that compared to the SO-SCLs, the maintenance of the PLTF on the SHWG-CLs was supported by the thicker and more stable PLTF.
Collapse
Affiliation(s)
- Norihiko Yokoi
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan
| | - Yuki Furusawa
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan
| | - Hiroaki Kato
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan
| | - Natsuki Kusada
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan
| | - Chie Sotozono
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan
| | - Petar Eftimov
- Department of Cell and Developmental Biology, Faculty of Biology, St. Kliment Ohridski University of Sofia, 1164 Sofia, Bulgaria;
| | - Georgi As. Georgiev
- Department of Optics and Spectroscopy, Faculty of Physics, St. Kliment Ohridski University of Sofia, 1164 Sofia, Bulgaria;
| |
Collapse
|
5
|
Haworth K, Travis D, Leslie L, Fuller D, Pucker AD. Silicone hydrogel versus hydrogel soft contact lenses for differences in patient-reported eye comfort and safety. Cochrane Database Syst Rev 2023; 9:CD014791. [PMID: 37724689 PMCID: PMC10507745 DOI: 10.1002/14651858.cd014791.pub2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/21/2023]
Abstract
BACKGROUND Ocular discomfort is the leading cause of permanent discontinuation of soft contact lens (SCL) wear. Silicone hydrogel and hydrogel materials are the two major categories of SCLs, with silicone hydrogel materials being newer and more breathable than hydrogel materials. Whether comfort is associated with SCL material is controversial despite numerous studies. Similarly, the difference between these materials in terms of safety outcomes (e.g. frequency of microbial keratitis) is unclear. OBJECTIVES To evaluate the comparative effectiveness and safety of silicone hydrogel compared with hydrogel SCLs on self-reported comfort, dry eye test results, and adverse events in SCL-wearing adults 18 years of age or older. SEARCH METHODS The Cochrane Eyes and Vision Information Specialist searched the electronic databases for randomized controlled trials (RCTs). There were no restrictions on language or date of publication. We searched the Cochrane Central Register of Controlled Trials (CENTRAL, including the Cochrane Eyes and Vision Trials Register; 2022, Issue 6), MEDLINE Ovid, Embase.com, PubMed, LILACS (Latin American and Caribbean Health Science Information database), ClinicalTrials.gov, and World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP). We also searched the reference lists of identified studies, review articles, and guidelines for information about relevant studies that may not have been identified by our search strategy. Furthermore, we contacted investigators regarding ongoing trials. The most recent database search was conducted on 24 June 2022. SELECTION CRITERIA Our search selection criteria included RCTs, quasi-RCTs, and cross-over RCTs. DATA COLLECTION AND ANALYSIS We applied standard Cochrane methodology. MAIN RESULTS We included seven parallel-group RCTs conducted in the USA, the UK, Australia, Germany, India, and Turkey. A total of 1371 participants were randomized. The duration of SCL wear ranged from one to 52 weeks. Study characteristics and risk of bias The median number of participants per trial was 120 (interquartile range: 51 to 314), and the average age ranged from 20.7 to 33.0 years. Women represented the majority of participants (range 55% to 74.9%; 5 RCTs). Collectively, the included trials compared eight different silicone hydrogel SCLs with three different hydrogel SCLs. Five trials compared daily disposable SCLs, and two compared extended wear SCLs (worn for seven days and six nights). New SCL wearers were enrolled in three trials. Two trials included both new and established SCL wearers, and two trials did not report participants' history of SCL use. Five trials were sponsored by industry. We judged the overall risk of bias to be 'high' or 'some concerns' for the safety and efficacy outcomes. Findings One trial reported Ocular Surface Disease Index (OSDI) results, with the evidence being very uncertain about the effects of SCL material on OSDI scores (mean difference -1.20, 95% confidence interval [CI] -10.49 to 8.09; 1 RCT, 47 participants; very low certainty evidence). Three trials reported visual analog scale comfort score results, with no clear difference in comfort between materials, but the evidence was of very low certainty; trial results could not be combined because the three trials reported results at different time points. The evidence is very uncertain about the effect of SCL material on discontinuation of contact lens wear (risk ratio [RR] 0.64, 95% CI 0.11 to 3.74; 1 RCT, 248 participants). None of the included trials reported Contact Lens Dry Eye Questionnaire (CLDEQ-8) or Standard Patient Evaluation of Eye Dryness (SPEED) scores. There was no evidence of a clinically meaningful difference (> 0.5 unit) between daily disposable silicone hydrogel and hydrogel SCLs in corneal staining, conjunctival staining, or conjunctival redness (very low certainty evidence). Adverse events Very low certainty evidence from two trials comparing daily disposable SCLs suggested no evidence of a difference between lens materials in the risk of vision-threatening adverse events at one to four weeks (RR 0.68, 95% CI 0.08 to 5.51; 2 RCTs, 368 participants). Two trials comparing extended wear SCLs indicated that hydrogel SCLs may have a 2.03 times lower risk of adverse events at 52 weeks compared with silicone hydrogel SCLs (RR 2.03, 95% CI 1.38 to 2.99; 815 participants), but the certainty of evidence was very low. AUTHORS' CONCLUSIONS The overall evidence for a difference between all included silicone hydrogel and hydrogel SCLs was of very low certainty, with most trials at high overall risk of bias. The majority of studies did not assess comfort using a validated instrument. There was insufficient evidence to support recommending one SCL material over the other. For extended wear, hydrogel SCL may have a lower risk of adverse events at 52 weeks compared to silicon hydrogel. Future well-designed trials are needed to generate high certainty evidence to further clarify differences in SCL material comfort and safety.
Collapse
Affiliation(s)
| | - Darian Travis
- School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Louis Leslie
- Department of Ophthalmology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Daniel Fuller
- Cornea Contact Lens Service, The Eye Center, Southern College of Optometry, Memphis, TN, USA
| | - Andrew D Pucker
- School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, USA
| |
Collapse
|
6
|
Penbe A, Kanar HS, Donmez Gun R. Comparison of the Pre-Lens Tear Film Stability and Visual Performance of a Novel and Two Other Daily Disposable Contact Lenses in Healthcare Professionals Wearing Facial Masks for Prolonged Time. CLINICAL OPTOMETRY 2022; 14:183-192. [PMID: 36246994 PMCID: PMC9562811 DOI: 10.2147/opto.s384246] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Accepted: 09/19/2022] [Indexed: 06/16/2023]
Abstract
OBJECTIVE To compare a novel daily disposable contact lens (DDCL) verofilcon A with other DDCL materials in terms of pre-lens tear film (PLTF) stabilization and visual performance for prolonged use in healthcare professionals with the use of masks. METHODS Subjects aged 20-40 years old were prospectively randomized into three study groups. Group 1: verofilcon A, group 2: nesofilcon A and group 3: senofilcon A. The subjects were evaluated at baseline with best corrected visual acuity (BCVA), non-invasive tear break up time (NIBUT) of pre-lens tear film, and high order aberrations (HoAs). After 28 days of CL use, NIBUT at 1, 4, 8, and 12 h, HoAs, contrast sensitivity (CS) with CVS100-E and contact lens dry eye questionnaire-8 (CLDEQ-8) were evaluated. RESULTS Between August and September 2021, 147 eyes of 77 subjects were included in the three study groups. At day 28, the CS scores at 18 cycles per degree, spatial frequencies, and the mean NIBUT scores at 4, 8, and 12 h were higher in the verofilcon A group compared to the nesofilcon A and at 12 h were higher compared to the senofilcon A (p < 0.05). The mean HoAs and CLDEQ-8 test scores were higher in the nesofilcon A group (p < 0.001). CONCLUSION The results of this study suggest the superiority of the PLTF stabilization ability of verofilcon A in healthcare professionals with prolonged use of mask. The improved CS and NIBUT scores of this lens could be explained by a new and unique surface technology with greater than 80% water content.
Collapse
Affiliation(s)
- Aysegul Penbe
- Department of Ophthalmology, Health Science University, Kartal Dr. Lutfi Kirdar Training and Research Hospital, Istanbul, Turkey
| | - Hatice Selen Kanar
- Department of Ophthalmology, Health Science University, Kartal Dr. Lutfi Kirdar Training and Research Hospital, Istanbul, Turkey
| | - Raziye Donmez Gun
- Department of Ophthalmology, Health Science University, Kartal Dr. Lutfi Kirdar Training and Research Hospital, Istanbul, Turkey
| |
Collapse
|