1
|
Orlov AV, Malkerov JA, Novichikhin DO, Znoyko SL, Nikitin PI. Multiplex Label-Free Kinetic Characterization of Antibodies for Rapid Sensitive Cardiac Troponin I Detection Based on Functionalized Magnetic Nanotags. Int J Mol Sci 2022; 23:ijms23094474. [PMID: 35562865 PMCID: PMC9102693 DOI: 10.3390/ijms23094474] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 04/12/2022] [Accepted: 04/15/2022] [Indexed: 02/04/2023] Open
Abstract
Express and highly sensitive immunoassays for the quantitative registration of cardiac troponin I (cTnI) are in high demand for early point-of-care differential diagnosis of acute myocardial infarction. The selection of antibodies that feature rapid and tight binding with antigens is crucial for immunoassay rate and sensitivity. A method is presented for the selection of the most promising clones for advanced immunoassays via simultaneous characterization of interaction kinetics of different monoclonal antibodies (mAb) using a direct label-free method of multiplex spectral correlation interferometry. mAb-cTnI interactions were real-time registered on an epoxy-modified microarray glass sensor chip that did not require activation. The covalent immobilization of mAb microdots on its surface provided versatility, convenience, and virtually unlimited multiplexing potential. The kinetics of tracer antibody interaction with the “cTnI—capture antibody” complex was characterized. Algorithms are shown for excluding mutual competition of the tracer/capture antibodies and selecting the optimal pairs for different assay formats. Using the selected mAbs, a lateral flow assay was developed for rapid quantitative cTnI determination based on electronic detection of functionalized magnetic nanoparticles applied as labels (detection limit—0.08 ng/mL, dynamic range > 3 orders). The method can be extended to other molecular biomarkers for high-throughput screening of mAbs and rational development of immunoassays.
Collapse
Affiliation(s)
- Alexey V. Orlov
- Prokhorov General Physics Institute of the Russian Academy of Sciences, 38 Vavilov St, 119991 Moscow, Russia; (J.A.M.); (D.O.N.); (S.L.Z.)
- Correspondence: (A.V.O.); (P.I.N.)
| | - Juri A. Malkerov
- Prokhorov General Physics Institute of the Russian Academy of Sciences, 38 Vavilov St, 119991 Moscow, Russia; (J.A.M.); (D.O.N.); (S.L.Z.)
- National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), 31 Kashirskoe Shosse, 115409 Moscow, Russia
| | - Denis O. Novichikhin
- Prokhorov General Physics Institute of the Russian Academy of Sciences, 38 Vavilov St, 119991 Moscow, Russia; (J.A.M.); (D.O.N.); (S.L.Z.)
- National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), 31 Kashirskoe Shosse, 115409 Moscow, Russia
| | - Sergey L. Znoyko
- Prokhorov General Physics Institute of the Russian Academy of Sciences, 38 Vavilov St, 119991 Moscow, Russia; (J.A.M.); (D.O.N.); (S.L.Z.)
| | - Petr I. Nikitin
- Prokhorov General Physics Institute of the Russian Academy of Sciences, 38 Vavilov St, 119991 Moscow, Russia; (J.A.M.); (D.O.N.); (S.L.Z.)
- National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), 31 Kashirskoe Shosse, 115409 Moscow, Russia
- Correspondence: (A.V.O.); (P.I.N.)
| |
Collapse
|
2
|
Ma H, Cassedy A, Ó'Fágáin C, O'Kennedy R. Generation, selection and modification of anti-cardiac troponin I antibodies with high specificity and affinity. J Immunol Methods 2021; 500:113183. [PMID: 34774542 DOI: 10.1016/j.jim.2021.113183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 10/27/2021] [Accepted: 11/03/2021] [Indexed: 11/18/2022]
Abstract
Current diagnosis of acute myocardial infarction involves quantification of circulating cTn levels. This work endeavoured to generate and enhance recombinant antibody fragments targeting various epitopes on the N- and C-terminals of the cTnI molecule, thereby facilitating highly sensitive detection of the troponin molecule. From this approach, two anti-cTnI scFv antibodies were successfully selected using either phage display or structural reformatting of full length anti-cTnI IgG. Their antibody binding affinity was further optimised via chain shuffling and/or site directed mutagenesis, resulting in scFv with heightened sensitivity when compared to the wild-type scFv. If used in conjunction with existing anti-mid fragment cTnI antibodies, these N- and C- terminal-targeting scFvs show high potential for the enhancement of current cTnI detection assays by limiting the effects from cTnI degradation or troponin complex formation.
Collapse
Affiliation(s)
- Hui Ma
- School of Biotechnology, Dublin City University, Dublin 9, D09 V2O9, Ireland
| | - Arabelle Cassedy
- School of Biotechnology, Dublin City University, Dublin 9, D09 V2O9, Ireland
| | - Ciarán Ó'Fágáin
- School of Biotechnology, Dublin City University, Dublin 9, D09 V2O9, Ireland
| | - Richard O'Kennedy
- School of Biotechnology, Dublin City University, Dublin 9, D09 V2O9, Ireland; Qatar Foundation, Research, Development and Innovation, and Hamad Bin Khalifa University, Education City, Doha, Qatar.
| |
Collapse
|
3
|
Supersensitive photon upconversion based immunoassay for detection of cardiac troponin I in human plasma. Clin Chim Acta 2021; 523:380-385. [PMID: 34688634 DOI: 10.1016/j.cca.2021.10.023] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 10/19/2021] [Accepted: 10/19/2021] [Indexed: 11/20/2022]
Abstract
BACKGROUND AND AIMS Upconverting nanoparticles (UCNPs) are attractive reporters for immunoassays due to their excellent detectability. Assays sensitive enough to measure baseline level of cardiac troponin I cTnI in healthy population could be used to identify patients at risk for cardiovascular disease. Aiming for a cTnI assay of such sensitivity, the surface chemistry of the nanoparticles as well as the assay reagents and the protocol were optimized for monodispersity of the UCNP antibody conjugates (Mab UCNPs) and to minimize their non-specific interactions with the solid support. MATERIALS AND METHODS UCNPs were coated with poly(acrylic acid) via two-step ligand exchange and conjugated with monoclonal antibodies. The conjugates were applied in a microplate-based sandwich immunoassay using a combination of two capture antibodies to detect cTnI. Assay was evaluated according to guidelines of Clinical & Laboratory Standards Institute. RESULTS The limit of detection and limit of blank of the assay were 0.13 ng/L and 0.01 ng/L cTnI, respectively. The recoveries were >90% in spiked plasma in the linear range. The within- and between-run imprecisions were <10%. CONCLUSION The results demonstrate that UCNPs enable quantification of cTnI concentrations expected in plasma of healthy individuals and could be used to identify patients at risk for cardiovascular disease.
Collapse
|
4
|
Fluorescent Immunoassay for Determination of Staphylococcal Enterotoxin A in Milk by Immobilized F(ab')2 Fragment of Anti-enterotoxin A Monoclonal Antibody. FOOD ANAL METHOD 2021. [DOI: 10.1007/s12161-021-02019-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
5
|
Regan B, O'Kennedy R, Collins D. Advances in point-of-care testing for cardiovascular diseases. Adv Clin Chem 2021; 104:1-70. [PMID: 34462053 DOI: 10.1016/bs.acc.2020.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Point-of-care testing (POCT) is a specific format of diagnostic testing that is conducted without accompanying infrastructure or sophisticated instrumentation. Traditionally, such rapid sample-to-answer assays provide inferior analytical performances to their laboratory counterparts when measuring cardiac biomarkers. Hence, their potentially broad applicability is somewhat bound by their inability to detect clinically relevant concentrations of cardiac troponin (cTn) in the early stages of myocardial injury. However, the continuous refinement of biorecognition elements, the optimization of detection techniques, and the fabrication of tailored fluid handling systems to manage the sensing process has stimulated the production of commercial assays that can support accelerated diagnostic pathways. This review will present the latest commercial POC assays and examine their impact on clinical decision-making. The individual elements that constitute POC assays will be explored, with an emphasis on aspects that contribute to economically feasible and highly sensitive assays. Furthermore, the prospect of POCT imparting a greater influence on early interventions for medium to high-risk individuals and the potential to re-shape the paradigm of cardiovascular risk assessments will be discussed.
Collapse
Affiliation(s)
- Brian Regan
- School of Biotechnology, Dublin City University, Dublin, Ireland.
| | - Richard O'Kennedy
- School of Biotechnology, Dublin City University, Dublin, Ireland; Research Complex, Hamad Bin Khalifa University, Qatar Foundation, Doha, Qatar
| | - David Collins
- School of Biotechnology, Dublin City University, Dublin, Ireland
| |
Collapse
|
6
|
Ma H, Cassedy A, O'Kennedy R. The role of antibody-based troponin detection in cardiovascular disease: A critical assessment. J Immunol Methods 2021; 497:113108. [PMID: 34329690 PMCID: PMC8412434 DOI: 10.1016/j.jim.2021.113108] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 07/13/2021] [Accepted: 07/24/2021] [Indexed: 01/19/2023]
Abstract
Cardiovascular disease has remained the world's biggest killer for 30 years. To aid in the diagnosis and prognosis of patients suffering cardiovascular-related disease accurate detection methods are essential. For over 20 years, the cardiac-specific troponins, I (cTnI) and T (cTnT), have acted as sensitive and specific biomarkers to assist in the diagnosis of various types of heart diseases. Various cardiovascular complications were commonly detected in patients with COVID-19, where cTn elevation is detectable, which suggested potential great prognostic value of cTn in COVID-19-infected patients. Detection of these biomarkers circulating in the bloodstream is generally facilitated by immunoassays employing cTnI- and/or cTnT-specific antibodies. While several anti-troponin assays are commercially available, there are still obstacles to overcome to achieve optimal troponin detection. Such obstacles include the proteolytic degradation of N and C terminals on cTnI, epitope occlusion of troponin binding-sites by the cTnI/cTnT complex, cross reactivity of antibodies with skeletal troponins or assay interference caused by human anti-species antibodies. Therefore, further research into multi-antibody based platforms, multi-epitope targeting and rigorous validation of immunoassays is required to ensure accurate measurements. Moreover, with combination and modification of various latest technical (e.g. microfluidics), antibody-based troponin detection systems can be more specific, sensitive and rapid which could be incorporated into portable biosensor systems to be used at point-of care.
Collapse
Affiliation(s)
- Hui Ma
- School of Biotechnology, Dublin City University, Dublin 9 D09 V2O9, Ireland
| | - Arabelle Cassedy
- School of Biotechnology, Dublin City University, Dublin 9 D09 V2O9, Ireland
| | - Richard O'Kennedy
- School of Biotechnology, Dublin City University, Dublin 9 D09 V2O9, Ireland; Qatar Foundation and Hamad Bin Khalifa University, Research Complex, Education City, Doha, Qatar.
| |
Collapse
|
7
|
Becheva ZR, Atanasova MK, Ivanov YL, Godjevargova TI. Magnetic Nanoparticle-Based Fluorescence Immunoassay for Determination of Ochratoxin A in Milk. FOOD ANAL METHOD 2020. [DOI: 10.1007/s12161-020-01848-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
8
|
Regan B, O'Kennedy R, Collins D. Point-of-Care Compatibility of Ultra-Sensitive Detection Techniques for the Cardiac Biomarker Troponin I-Challenges and Potential Value. BIOSENSORS 2018; 8:E114. [PMID: 30469415 PMCID: PMC6316850 DOI: 10.3390/bios8040114] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/16/2018] [Revised: 11/05/2018] [Accepted: 11/12/2018] [Indexed: 12/21/2022]
Abstract
Cardiac biomarkers are frequently measured to provide guidance on the well-being of a patient in relation to cardiac health with many assays having been developed and widely utilised in clinical assessment. Effectively treating and managing cardiovascular disease (CVD) relies on swiftly responding to signs of cardiac symptoms, thus providing a basis for enhanced patient management and an overall better health outcome. Ultra-sensitive cardiac biomarker detection techniques play a pivotal role in improving the diagnostic capacity of an assay and thus enabling a better-informed decision. However, currently, the typical approach taken within healthcare depends on centralised laboratories performing analysis of cardiac biomarkers, thus restricting the roll-out of rapid diagnostics. Point-of-care testing (POCT) involves conducting the diagnostic test in the presence of the patient, with a short turnaround time, requiring small sample volumes without compromising the sensitivity of the assay. This technology is ideal for combatting CVD, thus the formulation of ultra-sensitive assays and the design of biosensors will be critically evaluated, focusing on the feasibility of these techniques for point-of-care (POC) integration. Moreover, there are several key factors, which in combination, contribute to the development of ultra-sensitive techniques, namely the incorporation of nanomaterials for sensitivity enhancement and manipulation of labelling methods. This review will explore the latest developments in cardiac biomarker detection, primarily focusing on the detection of cardiac troponin I (cTnI). Highly sensitive detection of cTnI is of paramount importance regarding the rapid rule-in/rule-out of acute myocardial infarction (AMI). Thus the challenges encountered during cTnI measurements are outlined in detail to assist in demonstrating the drawbacks of current commercial assays and the obstructions to standardisation. Furthermore, the added benefits of introducing multi-biomarker panels are reviewed, several key biomarkers are evaluated and the analytical benefits provided by multimarkers-based methods are highlighted.
Collapse
Affiliation(s)
- Brian Regan
- School of Biotechnology, Dublin City University, 9 Dublin, Ireland.
| | - Richard O'Kennedy
- School of Biotechnology, Dublin City University, 9 Dublin, Ireland.
- Research Complex, Hamad Bin Khalifa University, Qatar Foundation, P.O. Box 34110 Doha, Qatar.
| | - David Collins
- School of Biotechnology, Dublin City University, 9 Dublin, Ireland.
| |
Collapse
|
9
|
Hernández-Albors A, Colom G, Salvador JP, Marco MP. Studies towards hcTnI Immunodetection Using Electrochemical Approaches Based on Magnetic Microbeads. SENSORS (BASEL, SWITZERLAND) 2018; 18:E2457. [PMID: 30060625 PMCID: PMC6111321 DOI: 10.3390/s18082457] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2018] [Revised: 07/26/2018] [Accepted: 07/27/2018] [Indexed: 11/29/2022]
Abstract
Different electrochemical strategies based on the use of magnetic beads are described in this work for the detection of human cardiac troponin I (hcTnI). hcTnI is also known as the gold standard for acute myocardial infarction (AMI) diagnosis according to the different guidelines from the European Society of Cardiology (ESC) and the American College of Cardiology (ACC). Amperometric and voltamperometric sandwich magnetoimmunoassays were developed by biofunctionalization of paramagnetic beads with specific antibodies. These bioconjugates were combined with biotinylated antibodies as detection antibodies, with the aim of testing different electrochemical transduction principles. Streptavidin labeled with horseradish peroxidase was used for the amperometric magnetoimmunoassay, reaching a detectability of 0.005 ± 0.002 µg mL-1 in 30 min. Cadmium quantum dots-streptavidin bioconjugates were used in the case of the voltamperometric immunosensor reaching a detectability of 0.023 ± 0.014 µg mL-1.
Collapse
Affiliation(s)
- Alejandro Hernández-Albors
- Nanobiotechnology for Diagnostics (Nb4D), Department of Chemical and Biomolecular Nanotechnology, Institute for Advanced Chemistry of Catalonia (IQAC) of the Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, 08034 Barcelona, Spain.
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034 Barcelona, Spain.
| | - Gloria Colom
- Nanobiotechnology for Diagnostics (Nb4D), Department of Chemical and Biomolecular Nanotechnology, Institute for Advanced Chemistry of Catalonia (IQAC) of the Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, 08034 Barcelona, Spain.
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034 Barcelona, Spain.
| | - J-Pablo Salvador
- Nanobiotechnology for Diagnostics (Nb4D), Department of Chemical and Biomolecular Nanotechnology, Institute for Advanced Chemistry of Catalonia (IQAC) of the Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, 08034 Barcelona, Spain.
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034 Barcelona, Spain.
| | - M-Pilar Marco
- Nanobiotechnology for Diagnostics (Nb4D), Department of Chemical and Biomolecular Nanotechnology, Institute for Advanced Chemistry of Catalonia (IQAC) of the Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, 08034 Barcelona, Spain.
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034 Barcelona, Spain.
| |
Collapse
|
10
|
Fathil M, Md Arshad M, Ruslinda A, Nuzaihan M.N. M, Gopinath SC, Adzhri R, Hashim U. Progression in sensing cardiac troponin biomarker charge transductions on semiconducting nanomaterials. Anal Chim Acta 2016; 935:30-43. [DOI: 10.1016/j.aca.2016.06.012] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2016] [Revised: 05/19/2016] [Accepted: 06/07/2016] [Indexed: 01/27/2023]
|
11
|
Sirkka N, Lyytikäinen A, Savukoski T, Soukka T. Upconverting nanophosphors as reporters in a highly sensitive heterogeneous immunoassay for cardiac troponin I. Anal Chim Acta 2016; 925:82-7. [DOI: 10.1016/j.aca.2016.04.027] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Revised: 04/13/2016] [Accepted: 04/20/2016] [Indexed: 11/25/2022]
|
12
|
Mourão CA, Carmignotto GP, Bueno SMA. Separation of human IgG fragments using copper, nickel, zinc, and cobalt chelated to CM-Asp-agarose by positive and negative chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1017-1018:163-173. [DOI: 10.1016/j.jchromb.2016.01.058] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2015] [Revised: 01/20/2016] [Accepted: 01/30/2016] [Indexed: 10/22/2022]
|
13
|
Nanocomposites of gold nanoparticles and graphene oxide towards an stable label-free electrochemical immunosensor for detection of cardiac marker troponin-I. Anal Chim Acta 2016; 909:1-8. [DOI: 10.1016/j.aca.2015.12.023] [Citation(s) in RCA: 99] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2015] [Revised: 12/14/2015] [Accepted: 12/15/2015] [Indexed: 12/12/2022]
|
14
|
Juntunen E, Arppe R, Kalliomäki L, Salminen T, Talha SM, Myyryläinen T, Soukka T, Pettersson K. Effects of blood sample anticoagulants on lateral flow assays using luminescent photon-upconverting and Eu(III) nanoparticle reporters. Anal Biochem 2015; 492:13-20. [PMID: 26408349 DOI: 10.1016/j.ab.2015.09.009] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2015] [Revised: 09/03/2015] [Accepted: 09/10/2015] [Indexed: 12/27/2022]
Abstract
Many quantitative and semiquantitative lateral flow (LF) assays have been introduced for clinical analytes such as biomarkers for cancer or acute myocardial infarction (AMI). Various detection technologies involving quantitative analyzing devices have been reported to have sufficient analytical sensitivity and quantification capability for clinical point-of-care tests. Fluorescence-based detection technologies such as quantum dots, Eu(III) nanoparticles, and photon-upconverting nanoparticles (UCNPs) have been introduced as promising solutions for point-of-care devices because of their high detectability by optical sensors. Lateral flow assays can be used for various sample types, e.g., urine, saliva, cerebrospinal fluid, and blood. This study focuses on the properties of serum and plasma because of their relevance in cancer and AMI diagnostics. The limit of detection was compared in LF assays having Eu(III) nanoparticles or UCNPs as reporters and the antibody configurations for two different analytes (prostate-specific antigen and cardiac troponin I (cTnI)). The results indicate a significant effect of anticoagulants in venipuncture tubes. The samples in K3EDTA tubes resulted in significant interference by decreased reporter particle mobility, and thus the limit of detection was up to eightfold less sensitive compared to serum samples. Despite the matrix interference in the cTnI assay with UCNP reporters, limits of detection of 41 ng/L with serum and 66 ng/L with the Li-heparin sample were obtained.
Collapse
Affiliation(s)
- Etvi Juntunen
- Department of Biotechnology, University of Turku, 20520 Turku, Finland.
| | - Riikka Arppe
- Department of Biotechnology, University of Turku, 20520 Turku, Finland
| | - Laura Kalliomäki
- Department of Biotechnology, University of Turku, 20520 Turku, Finland
| | - Teppo Salminen
- Department of Biotechnology, University of Turku, 20520 Turku, Finland
| | - Sheikh M Talha
- Department of Biotechnology, University of Turku, 20520 Turku, Finland
| | - Tiina Myyryläinen
- Department of Biotechnology, University of Turku, 20520 Turku, Finland
| | - Tero Soukka
- Department of Biotechnology, University of Turku, 20520 Turku, Finland
| | - Kim Pettersson
- Department of Biotechnology, University of Turku, 20520 Turku, Finland
| |
Collapse
|
15
|
Skeletal troponin I cross-reactivity in different cardiac troponin I assay versions. Clin Biochem 2015; 48:313-7. [DOI: 10.1016/j.clinbiochem.2014.12.028] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2014] [Revised: 12/30/2014] [Accepted: 12/30/2014] [Indexed: 11/23/2022]
|
16
|
Päkkilä H, Malmi E, Lahtinen S, Soukka T. Rapid homogeneous immunoassay for cardiac troponin I using switchable lanthanide luminescence. Biosens Bioelectron 2014; 62:201-7. [DOI: 10.1016/j.bios.2014.06.042] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2014] [Revised: 06/18/2014] [Accepted: 06/22/2014] [Indexed: 11/27/2022]
|
17
|
Hyytiä H, Heikkilä T, Brockmann EC, Kekki H, Hedberg P, Puolakanaho T, Lövgren T, Pettersson K. Chimeric recombinant antibody fragments in cardiac troponin I immunoassay. Clin Biochem 2014; 48:347-52. [PMID: 25111014 DOI: 10.1016/j.clinbiochem.2014.06.080] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2014] [Revised: 06/10/2014] [Accepted: 06/17/2014] [Indexed: 11/18/2022]
Abstract
OBJECTIVES To introduce a novel nanoparticle-based immunoassay for cardiac troponin I (cTnI) utilizing chimeric antibody fragments and to demonstrate that removal of antibody Fc-part and antibody chimerization decrease matrix related interferences. DESIGN AND METHODS A sandwich-type immunoassay for cTnI based on recombinant chimeric (mouse variable/human constant) antigen binding (cFab) antibodies and intrinsically fluorescent nanoparticles was developed. To test whether using chimeric antibody fragments helps to avoid matrix related interferences, samples (n=39) with known amounts of triglycerides, bilirubin, rheumatoid factor (RF) or human anti-mouse antibodies (HAMAs) were measured with the novel assay, along with a previously published nanoparticle-based research assay with the same antibody epitopes. RESULTS The limit of detection (LoD) was 3.30ng/L. Within-laboratory precision for 29ng/L and 2819ng/L cTnI were 13.7% and 15.9%, respectively. Regression analysis with Siemens ADVIA Centaur® yielded a slope (95% confidence intervals) of 0.18 (0.17-1.19) and a y-intercept of 1.94 (-1.28-3.91) ng/L. When compared to a previously published nanoparticle-based assay, the novel assay showed substantially reduced interference in the tested interference prone samples, 15.4 vs. 51.3%. A rheumatoid factor containing sample was decreased from 241ng/L to <LoD. CONCLUSIONS Utilization of cFab-fragments enabled the development of a sensitive (LoD=3.3ng/L) immunoassay for the detection of cTnI and decreased matrix related interferences, thus resulting in a lower number of falsely elevated cTnI-values.
Collapse
Affiliation(s)
- Heidi Hyytiä
- University of Turku, Department of Biotechnology, Tykistökatu 6 A, 20520 Turku, Finland.
| | - Taina Heikkilä
- University of Turku, Department of Biotechnology, Tykistökatu 6 A, 20520 Turku, Finland
| | | | - Henna Kekki
- University of Turku, Department of Biotechnology, Tykistökatu 6 A, 20520 Turku, Finland
| | - Pirjo Hedberg
- NordLab Oulu, Oulu University Hospital, Oulu, Finland; Department of Clinical Chemistry, University of Oulu, Oulu, Finland
| | - Tarja Puolakanaho
- NordLab Oulu, Oulu University Hospital, Oulu, Finland; Department of Clinical Chemistry, University of Oulu, Oulu, Finland
| | - Timo Lövgren
- University of Turku, Department of Biotechnology, Tykistökatu 6 A, 20520 Turku, Finland
| | - Kim Pettersson
- University of Turku, Department of Biotechnology, Tykistökatu 6 A, 20520 Turku, Finland
| |
Collapse
|
18
|
Hyytiä H, Ristiniemi N, Laitinen P, Lövgren T, Pettersson K. Extension of dynamic range of sensitive nanoparticle-based immunoassays. Anal Biochem 2013; 446:82-6. [PMID: 24211398 DOI: 10.1016/j.ab.2013.10.034] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2013] [Revised: 10/22/2013] [Accepted: 10/29/2013] [Indexed: 11/30/2022]
Abstract
Nanoparticles have successfully been employed in immunometric assays that require high sensitivity. Certain analytes, however, require dynamic ranges (DRs) around a predetermined cut-off value. Here, we have studied the effects that antibody orientation and addition of free solid-phase and detection antibodies have on assay sensitivity and DR in traditional sandwich-type immunoassays. D-dimer and cardiac troponin I (cTnI), both routinely used in critical care testing, were applied as model analytes. The assays were performed in microtitration wells with preimmobilized solid-phase antibody. Inherently fluorescent nanoparticles coated with second antibody were used to detect the analyte. The selection of antibody orientation and addition of free solid-phase or detection antibody, with nanoparticles and calibrator, desensitized the assays and extended the DR. With D-dimer the upper limit of the DR was improved from 50 to 10,000 ng/ml, and with cTnI from 25 to 1000 ng/ml. Regression analysis with the Stago STA Liatest D-dimer assay yielded a slope (95% confidence interval) of 0.09 (0.07-0.11) and a y-intercept of -7.79 (-17.87-2.29)ng/L (n=65, r=0.906). Thus it is concluded that Europium(III)-chelate-doped nanoparticles can also be employed in immunoassays that require wide DRs around a certain cut-off limit.
Collapse
Affiliation(s)
- Heidi Hyytiä
- Department of Biotechnology, University of Turku, 20520 Turku, Finland.
| | - Noora Ristiniemi
- Department of Biotechnology, University of Turku, 20520 Turku, Finland
| | - Päivi Laitinen
- HUSLAB, Department of Clinical Chemistry, Helsinki University Hospital, 00029 HUS Helsinki, Finland
| | - Timo Lövgren
- Department of Biotechnology, University of Turku, 20520 Turku, Finland
| | - Kim Pettersson
- Department of Biotechnology, University of Turku, 20520 Turku, Finland
| |
Collapse
|
19
|
Panteghini M. Avoid capture of interfering molecules in cardiac troponin immunoassays: Working in shifts. Clin Biochem 2013; 46:961-962. [DOI: 10.1016/j.clinbiochem.2013.06.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2013] [Revised: 05/14/2013] [Accepted: 06/03/2013] [Indexed: 10/26/2022]
|