1
|
Tanifuji O, Mochizuki T, Sato T, Watanabe S, Omori G, Kawashima H. Mobile medial pivot (lateral slide) type total knee arthroplasty exhibits a medial pivot pattern: three-dimensional motion analysis using cadaveric knees. J Exp Orthop 2022; 9:122. [PMID: 36520362 PMCID: PMC9755420 DOI: 10.1186/s40634-022-00558-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 11/30/2022] [Indexed: 12/23/2022] Open
Abstract
PURPOSE The purpose of this study was to analyze the dynamic kinematics of the mobile medial pivot-type total knee arthroplasty (MMPTKA) using the three-dimensional (3D)-to-2D registration technique. METHODS Cadaveric knees from five humans were used. Computed tomography of the lower limb and preoperative 3D planning for MMPTKA were performed. After performing TKA, passive motion of the knee was observed from a fully extended position to maximum flexion using a flat panel detector. The following parameters were determined: (1) anteroposterior (AP) translations of the medial and lateral most distal points (estimated contact point) of the femoral component, (2) rotational femoral component's X-axis (FCX) angle, and (3) rotational insert angle. Paired t-tests were used to analyze differences in the AP translation between the medial and lateral most distal points of the femoral component as well as differences in the changes in the rotational angle between the FCX and X-axis of the insert on the tibial component's axial plane. RESULTS The AP translations of the femoral component's medial and lateral most distal points were 8.4 ± 2.5 and 13.6 ± 3.3 mm, respectively (p = 0.001). The rotational angles of the FCX and insert were 10.7° ± 4.9° external rotation and 8.9° ± 4.1° internal rotation, respectively (p = 0.004). CONCLUSIONS The posterior translation of the lateral side of the femoral component was greater than that of the medial in all cases. Hence, a medial pivot pattern was identified. The femoral component exhibited external rotation throughout knee flexion in all subjects, whereas the mobile insert exhibited internal rotation (opposite pattern relative to the femoral component). This study provides valuable kinematical information of MMPTKA that has not been clear yet.
Collapse
Affiliation(s)
- Osamu Tanifuji
- grid.260975.f0000 0001 0671 5144Division of Orthopaedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medicine and Dental Science, 1-757 Asahimachi-Dori Chuo-Ku, Niigata, 951-8510 Japan
| | - Tomoharu Mochizuki
- grid.260975.f0000 0001 0671 5144Division of Orthopaedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medicine and Dental Science, 1-757 Asahimachi-Dori Chuo-Ku, Niigata, 951-8510 Japan
| | - Takashi Sato
- Department of Orthopaedic Surgery, Niigata Medical Center, Niigata, Japan
| | - Satoshi Watanabe
- Department of Orthopaedic Surgery, Niigata Medical Center, Niigata, Japan
| | - Go Omori
- grid.412183.d0000 0004 0635 1290Department of Health and Sports, Faculty of Health Sciences, Niigata University of Health and Welfare, Niigata, Japan
| | - Hiroyuki Kawashima
- grid.260975.f0000 0001 0671 5144Division of Orthopaedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medicine and Dental Science, 1-757 Asahimachi-Dori Chuo-Ku, Niigata, 951-8510 Japan
| |
Collapse
|
2
|
Biomechanical Particularities in the Therapy of the Rheumatic Knee. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10238600] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
In rheumatoid arthritis, the joints of the lower extremities are almost always affected. This is most conspicuous in the knee joint. In rheumatics, inflammatory osteoarthritis manifests itself comparably earlier than in patients with osteoarthritis. The focus of attention was primarily on the synovia with its destruction process and secondary changes. Now, driven by experimental research, dendritic cells and fibroblasts and molecular features are moving into the clinician’s field of vision. Even in joints that appear to be in remission with no swelling or pain, the activity of these cells leads to changes in the capsule-ligaments. The complex deformities and instabilities caused by this, in conjunction with atrophy of the inter-articular musculature, have an impact on the activities of daily life (ADL). If these biomechanical aspects of the knee joint are not taken into account early on in therapy, the frequency of primary and secondary surgical treatment increases. The timely recognition of biomechanical pathologies and consistent treatment can contribute to improving the patient situation in addition to adequate medication therapy.
Collapse
|
3
|
Hoshi K, Watanabe G, Kurose Y, Tanaka R, Fujii J, Gamada K. Mobile-bearing insert used with total knee arthroplasty does not rotate on the tibial tray during a squatting activity: a cross-sectional study. J Orthop Surg Res 2020; 15:114. [PMID: 32197628 PMCID: PMC7085202 DOI: 10.1186/s13018-020-1570-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Accepted: 01/23/2020] [Indexed: 11/25/2022] Open
Abstract
Background Total knee arthroplasty (TKA) is commonly performed around the world. Implant designs include fixed-bearing and mobile-bearing. Mobile-bearing design was developed as a rotating platform that allows axial rotation of the insert around the longitudinal axis. This phenomenon may limit full exploitation of the characteristics of the mobile-bearing insert, which may cause wearing and reduce longevity. However, there is limited knowledge on rotational behavior of the polyethylene mobile-bearing insert under weight-bearing conditions. We aimed at determining the rotational motion of each component at full extension and flexed positions during a squatting activity after TKA. Methods This study was a cross-sectional study (level 4) involving patients with severe knee osteoarthritis scheduled to receive TKA. We examined 13 knees of 11 patients after mobile-bearing TKA (NexGen LPS-Flex, Zimmer Inc.) at 10 weeks and 1 year postoperatively. Four identical metallic beads were embedded into the insert. Wide-base squatting was chosen for analyses. Three-dimensional in vivo poses of the prostheses were created using a 3D-to-2D registration technique. During flexion, rotation of the femoral component relative to the insert (FEM/INS) and tibial component (FEM/TIB) as well as insert rotation relative to the tibial component (INS/TIB) were computed. Repeated measure 2-way ANOVA and post hoc test was used. Results In the fully extended position, FEM/INS was significantly smaller than INS/TIB both at 10 weeks (− 0.3° vs. 6.3°, p = .013) and 1 year (− 0.8° vs. 4.9°, p = .011), respectively. During the squatting activity, rotation motions of FEM/TIB, FEM/INS, INS/TIB were 5.7°, 5.9°, and 1.8° at 10 weeks and 6.3°, 5.5°, and 1.6° at 1 year, respectively. Rotation motion of FEM/INS was significantly greater than that of INS/TIB at both 10 weeks (p < .001) and 1 year (p < .001). Conclusions The mobile-bearing insert enhances the compatibility of FEM/INS in extension; the amount of INS/TIB rotation is significantly smaller than that of FEM/INS during a squatting activity. This information will inform surgeons to take caution to perform TKA with a fixed insert in which 6.3° of rotational offset would be added to the rotational alignment at FEM/INS at full extension. Trial registration UMIN-CTR, UMIN000024196. Retrospectively registered on 9 September 2016.
Collapse
Affiliation(s)
- Kenji Hoshi
- Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, 555-36 Kurose-Gakuendai, Bldg3, Rm3807, Higashi-Hiroshima, Hiroshima, 739-2695, Japan
| | - Goro Watanabe
- Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, 555-36 Kurose-Gakuendai, Bldg3, Rm3807, Higashi-Hiroshima, Hiroshima, 739-2695, Japan
| | - Yasuo Kurose
- Hiroshima Prefectural Rehabilitation Center, 295-3 Taguchi, Saijo-cho, Higashi-Hiroshima, Hiroshima, 739-0036, Japan
| | - Ryuji Tanaka
- Hiroshima Prefectural Rehabilitation Center, 295-3 Taguchi, Saijo-cho, Higashi-Hiroshima, Hiroshima, 739-0036, Japan
| | - Jiro Fujii
- Hiroshima Prefectural Rehabilitation Center, 295-3 Taguchi, Saijo-cho, Higashi-Hiroshima, Hiroshima, 739-0036, Japan
| | - Kazuyoshi Gamada
- Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, 555-36 Kurose-Gakuendai, Bldg3, Rm3807, Higashi-Hiroshima, Hiroshima, 739-2695, Japan.
| |
Collapse
|
4
|
Park CH, Kang SG, Bae DK, Song SJ. Mid-term clinical and radiological results do not differ between fixed- and mobile-bearing total knee arthroplasty using titanium-nitride-coated posterior-stabilized prostheses: a prospective randomized controlled trial. Knee Surg Sports Traumatol Arthrosc 2019; 27:1165-1173. [PMID: 30088030 DOI: 10.1007/s00167-018-5095-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2018] [Accepted: 08/03/2018] [Indexed: 01/31/2023]
Abstract
PURPOSE This study was performed to prospectively compare the clinical and radiographic results between mobile-bearing (MB) and fixed-bearing (FB) TKAs using ceramic titanium nitride (TiN)-coated prostheses. METHODS Seventy MB and 70 FB TKAs using TiN-coated prostheses (ACS®) were prospectively evaluated. There were no differences in demographic characteristics between the two groups. Clinically, the Knee Society knee and function scores, WOMAC, and range of motion (ROM) were compared. Considering the possibility of a kinematic change in the polyethylene (PE) insert and a decrease in ROM following MB TKA, serial changes in the ROM were also compared. The thickness of the PE insert was compared according to the size of the femoral component. Radiographically, the alignment and positions of the components were compared. RESULTS There were no differences between the two groups in clinical scores or ROM (n.s.). The maximum flexion increased from 133.5° ± 8.3° to 137.6° ± 5.5° across all time points in the MB group. The serial maximum flexion angles did not differ between the two groups over time (n.s.). The average thickness of the PE insert was greater in the MB group (12.0 ± 1.9 vs. 11.2 ± 1.6 mm, respectively, p = 0.008), especially when a large femoral component was used (12.7 ± 1.9 vs. 11.0 ± 1.5 mm, p = 0.005). The pre- and postoperative mechanical axes and positions of the components did not differ between the two groups (n.s.). CONCLUSIONS TiN-coated MB TKA showed no significant advantage over FB TKA. The selection of bearing design would be clinically insignificant when using the TiN-coated TKA prosthesis. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Cheol Hee Park
- Department of Medicine, Graduate School, Kyung Hee University, 24 Kyunghee-daero, Dongdaemun-gu, Seoul, 02453, South Korea
| | - Se Gu Kang
- Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, 24 Kyunghee-daero, Dongdaemun-gu, Seoul, 02453, South Korea
| | - Dae Kyung Bae
- Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, 24 Kyunghee-daero, Dongdaemun-gu, Seoul, 02453, South Korea
| | - Sang Jun Song
- Department of Medicine, Graduate School, Kyung Hee University, 24 Kyunghee-daero, Dongdaemun-gu, Seoul, 02453, South Korea. .,Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, 24 Kyunghee-daero, Dongdaemun-gu, Seoul, 02453, South Korea.
| |
Collapse
|
5
|
Horsager K, Kaptein BL, Jørgensen PB, Jepsen CF, Stilling M. Oxford medial unicompartmental knees display contact-loss during step-cycle motion and bicycle motion: A dynamic radiostereometric study. J Orthop Res 2018; 36:357-364. [PMID: 28574622 DOI: 10.1002/jor.23625] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Accepted: 05/28/2017] [Indexed: 02/04/2023]
Abstract
The Oxford medial unicompartmental knee is designed fully congruent, with the purpose of maintaining a large contact-area throughout motion and minimize wear. No other study has investigated this design feature in-vivo. We aimed to evaluate if contact-loss was introduced between the articulating surfaces of the Oxford medial unicompartmental knee during bicycle- and step-cycle motion, and whether this correlated with essential implant parameters, such as polyethylene (PE) wear, knee-loadings, and clinical outcome. To study contact-loss, 15 patients (12 males, mean age 69 years) with an Oxford medial unicompartmental knee (7 cemented, mean follow-up 4.4 years) were examined with use of dynamic radiostereometry (RSA) (10 frames/s). PE wear was measured from static RSA and clinical outcome was evaluated with American Knee Society Score (AKSS) and Oxford Knee Score (OKS). Data on knee-loadings were acquired from the literature. Contact-loss was deteced in all patients during both exercises, and the trend of contact-loss correlated with the knee-loadings. Median contact-loss was 0.8 mm (95%PI: 0.3; 1.5) for bicycle motion and 0.3 mm (95%PI: 0.24; 0.35) for step-cycle motion, and did not correlate with the PE wear rate of mean 0.06 mm/year. Possible in-congruency was seen in three patients. Clinical outcome scores correlated with contact-loss during step-cycle motion. In conclusion, contact-loss was seen in all patients indicating a clinical tolerance during load. Contact-loss followed the knee-loadings, which could explain why no correlation was seen with PE wear, as an increase in load was acommadated by an increase in contact-area (contact-loss reduction). The size of contact-loss may reflect clinical outcome. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:357-364, 2018.
Collapse
Affiliation(s)
- Kristian Horsager
- Department of Orthopedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000, Aarhus, Denmark
| | - Bart L Kaptein
- Biomechanics and Imaging Group, Department of Orthopedic Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, Netherlands
| | - Peter B Jørgensen
- Department of Orthopedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000, Aarhus, Denmark
| | - Claus F Jepsen
- Department of Orthopedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000, Aarhus, Denmark
| | - Maiken Stilling
- Department of Orthopedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000, Aarhus, Denmark
| |
Collapse
|
6
|
Mobility of the rotating platform in low contact stress knee arthroplasty is durable. Knee Surg Sports Traumatol Arthrosc 2017; 25:2580-2585. [PMID: 26475152 DOI: 10.1007/s00167-015-3823-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2015] [Accepted: 09/25/2015] [Indexed: 10/22/2022]
Abstract
PURPOSE The mobile bearing or rotating platform (RP) in total knee arthroplasty (TKA) is originally part of a low contact stress (LCS) concept, with bearing undersurface mobility compensating higher bearing upper-surface congruency. The in vivo range of axial femorotibial rotation in RP knees has been the subject of many studies, but always involving the performance of relatively low demanding task conditions. Hardly any study has addressed the maintenance of this rotation over time. METHODS Two consecutive series of patients with LCS RP knees were studied in a cross-sectional study of 1- and 5-year follow-up. They were assessed using optoelectronic movement analysis during gait and the performance of a sit-to-walk (STW) task with and without turning steps. RESULTS A mean range of rotation (SD) was found in the 1-year group of 13.4° (3.7) during gait, 17.8° (6.8) during STW straight, and 17.9° (6.9) during STW with turning. The range in the 5-year group was 11.2° (6.0) during gait, 18.5° (8.7) during STW straight, and 18.3° (8.3) during STW with turning. A so-called paradoxical axial rotation pattern during gait and STW straight occurred in both groups in a normal prevalence. CONCLUSION The amount and pattern of rotation in a LCS RP knee does not become impaired between 1 and 5 years postoperatively. The theoretical benefit of RP TKA has not been proven in any clinical study so far, and studies with suitable long-term follow-up need to prove whether this mobility also leads to improved prosthesis survival. However, our findings support the functioning of the rotating platform at a basal science level and illustrate the need for the use of more complex tasks in kinematic studies. LEVEL OF EVIDENCE Therapeutic study, Level III.
Collapse
|
7
|
3D kinematics of mobile-bearing total knee arthroplasty using X-ray fluoroscopy. Int J Comput Assist Radiol Surg 2014; 10:487-95. [DOI: 10.1007/s11548-014-1093-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2014] [Accepted: 06/11/2014] [Indexed: 10/25/2022]
|
8
|
Urwin SG, Kader DF, Caplan N, St Clair Gibson A, Stewart S. Gait analysis of fixed bearing and mobile bearing total knee prostheses during walking: do mobile bearings offer functional advantages? Knee 2014; 21:391-5. [PMID: 24238651 DOI: 10.1016/j.knee.2013.10.007] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2013] [Revised: 10/02/2013] [Accepted: 10/17/2013] [Indexed: 02/02/2023]
Abstract
BACKGROUND Limited previous findings have detailed biomechanical advantages following implantation with mobile bearing (MB) prostheses after total knee replacement (TKR) surgery during walking. The aim of this study was to compare three dimensional spatiotemporal, kinematic, and kinetic parameters during walking to examine whether MBs offer functional advantages over fixed bearing (FB) designs. METHODS Sixteen patients undergoing primary unilateral TKR surgery were randomised to receive either a FB (n=8) or MB (n=8) total knee prosthesis. Eight age and gender matched controls underwent the same protocol on one occasion. A 12 camera Vicon system integrated with four force plates was used. Patients were tested pre-surgery and nine months post-surgery. RESULTS No significant differences between FB and MB groups were found at any time point in the spatiotemporal parameters. The MB group was found to have a significantly reduced frontal plane knee range of motion (ROM) at pre-surgery than the FB group (FB=14.92±4.02°; MB=8.87±4.82°), with the difference not observed post-surgery. No further significant kinematic or kinetic differences were observed between FB and MB groups. Fixed bearing and MB groups both displayed spatiotemporal, kinematic, and kinetic differences when compared to controls. Fixed bearing and MB groups differed from controls in six and five parameters at nine months post-surgery, respectively. CONCLUSIONS No functional advantages were found in knees implanted with MB prostheses during walking, with both groups indicative of similar differences when compared to normal knee biomechanics following prosthesis implantation. LEVEL OF EVIDENCE Level II.
Collapse
Affiliation(s)
- Samuel G Urwin
- Department of Sport, Exercise, and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK; Orthopaedic and Sports Injury Research Group, Queen Elizabeth Hospital, Sheriff Hill, Gateshead, UK.
| | - Deiary F Kader
- Orthopaedics and Trauma, Queen Elizabeth Hospital, Sheriff Hill, Gateshead, UK; Orthopaedic and Sports Injury Research Group, Queen Elizabeth Hospital, Sheriff Hill, Gateshead, UK
| | - Nick Caplan
- Department of Sport, Exercise, and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK; Orthopaedic and Sports Injury Research Group, Queen Elizabeth Hospital, Sheriff Hill, Gateshead, UK
| | - Alan St Clair Gibson
- Department of Sport, Exercise, and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK; Orthopaedic and Sports Injury Research Group, Queen Elizabeth Hospital, Sheriff Hill, Gateshead, UK
| | - Su Stewart
- Department of Sport, Exercise, and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK; Orthopaedic and Sports Injury Research Group, Queen Elizabeth Hospital, Sheriff Hill, Gateshead, UK
| |
Collapse
|
9
|
Verra WC, van den Boom LGH, Jacobs W, Clement DJ, Wymenga AAB, Nelissen RGHH. Retention versus sacrifice of the posterior cruciate ligament in total knee arthroplasty for treating osteoarthritis. Cochrane Database Syst Rev 2013; 2013:CD004803. [PMID: 24114343 PMCID: PMC6599815 DOI: 10.1002/14651858.cd004803.pub3] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND The functional and clinical basis on which to choose whether or not to retain the posterior cruciate ligament during total knee arthroplasty surgery remained unclear after a Cochrane systematic review and meta-analysis in 2005, which contained eight clinical trials. Several new trials have been conducted since then. Hence, an update of the review was performed. OBJECTIVES Our aim was to assess the benefits and harms of retention compared to sacrifice of the posterior cruciate ligament in total knee arthroplasty in patients with osteoarthritis of the knee. SEARCH METHODS An extensive search was conducted in CENTRAL, MEDLINE (PubMed), EMBASE, Web of Science, CINAHL, Academic Search Premier, Current Contents Connect and Science Direct. All databases were searched, without any limitations, up to 6 December 2012. References of the articles were checked and citation tracking was performed. SELECTION CRITERIA Randomised and quasi-randomised controlled trials comparing retention with sacrifice of the posterior cruciate ligament in primary total knee arthroplasty in patients with osteoarthritis of the knee. DATA COLLECTION AND ANALYSIS Data were collected with a pre-developed form. Risk of bias was assessed independently by two authors (WV, LB). The level of evidence was graded using the GRADE approach. Meta-analysis was performed by pooling the results of the selected studies, when possible. Subgroup analyses were performed for posterior cruciate ligament retention versus sacrifice using the same total knee arthroplasty design, and for studies using a posterior cruciate ligament retaining or posterior stabilised design, and when sufficient studies were available subgroup analyses were performed for the same brand. MAIN RESULTS Seventeen randomised controlled trials (with 1810 patients and 2206 knees) were found, described in 18 articles. Ten of these were new studies compared to the previous Cochrane Review. One study from the original Cochrane review was excluded. Most new studies compared a posterior cruciate ligament retaining design with a posterior stabilised design, in which the posterior cruciate ligament is sacrificed (a posterior stabilised design has an insert with a central post which can engage on a femoral cam during flexion).The quality of evidence (graded with the GRADE approach) and the risk of bias were highly variable, ranging from moderate to low quality evidence and with unclear or low risk of bias for most domains, respectively.The performance outcome 'range of motion' was 2.4 ° higher in favour of posterior cruciate ligament sacrifice (118.3 ° versus 115.9 °; 95% confidence interval (CI) of the difference 0.13 to 4.67; P = 0.04), however the results were heterogeneous. On the item 'knee pain' as experienced by patients, meta-analysis could be performed on the Knee Society knee pain score; this score was 48.3 in both groups, yielding no difference between the groups. Implant survival rate could not be meta-analysed adequately since randomised controlled trials lack the longer term follow-up in order to evaluate implant survival. A total of four revisions in the cruciate-retention and four revisions in the cruciate-sacrifice group were found. The well-validated Western Ontario and McMaster Universities osteoarthritis index (WOMAC) total score was not statistically significantly different between the groups (16.6 points for cruciate-retention versus 15.0 points for cruciate-sacrifice). One study reported a patient satisfaction grade (7.7 points for cruciate-retention versus 7.9 points for cruciate-sacrifice on a scale from 0 to 10, 10 being completely satisfied) which did not differ statistically significantly. Complications were distributed equally between both groups. Only one study reported several re-operations other than revision surgery; that is patella luxations, surgical manipulation because of impaired flexion.The mean functional Knee Society Score was 2.3 points higher (81.2 versus 79.0 points; 95% CI of the difference 0.37 to 4.26; P = 0.02) in the posterior cruciate ligament sacrificing group. Results from the outcome Knee Society functional score were homogeneous. All other outcome measures (extension angle, knee pain, adverse effects, clinical questionnaire scores, Knee Society clinical scores, radiological rollback, radiolucencies, femorotibial angle and tibial slope) showed no statistically significant differences between the groups. In the subgroup analyses that allowed pooling of the results of the different studies, no homogeneous statistically significant differences were identified. AUTHORS' CONCLUSIONS The methodological quality and the quality of reporting of the studies were highly variable. With respect to range of motion, pain, clinical, and radiological outcomes, no clinically relevant differences were found between total knee arthroplasty with retention or sacrifice of the posterior cruciate ligament. Two statistically significant differences were found; range of motion was 2.4 ° higher in the posterior cruciate ligament sacrificing group, however results were heterogeneous; and the mean functional Knee Society Score was 2.3 points higher in the posterior cruciate ligament sacrificing group. These differences are clinically not relevant.
Collapse
Affiliation(s)
- Wiebe C Verra
- Leiden University Medical CenterDepartment of OrthopedicsAlbinusdreef 2LeidenNetherlands2333 ZA
| | - Lennard GH van den Boom
- University Medical Center GroningenDepartment of OrthopedicsHanzeplein 1GroningenNetherlands9713 GZ
| | - Wilco Jacobs
- Leiden University Medical CenterDepartment of NeurosurgeryPO Box 9600LeidenNetherlands2300 RC
| | - Darren J Clement
- School of Medicine, University Hospital of North StraffordshireMedical Research UnitThornburrow DriveHartshillUK
| | - Ate AB Wymenga
- Sint MaartenskliniekDepartment of OrthopedicsPO Box 9011NijmegenNetherlands6500 GM
| | - Rob GHH Nelissen
- Leiden University Medical CenterDepartment of OrthopedicsAlbinusdreef 2LeidenNetherlands2333 ZA
| |
Collapse
|
10
|
Wolterbeek N, Garling EH, Mertens BJA, van der Linden HMJ, Nelissen RGHH, Valstar ER. Kinematics of a highly congruent mobile-bearing total knee prosthesis. Knee Surg Sports Traumatol Arthrosc 2012; 20:2487-93. [PMID: 22426852 DOI: 10.1007/s00167-012-1936-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2011] [Accepted: 02/20/2012] [Indexed: 11/30/2022]
Abstract
PURPOSE Limited or absent axial rotation of the mobile insert of total knee prostheses could lead to high contact stresses and stresses at the bone-implant interface, which in turn might lead to implant loosening. The aim of this study was to assess knee kinematics and muscle activation and their possible change over time in patients with a highly congruent, mobile-bearing total knee prosthesis. METHODS A prospective series of 11 rheumatoid arthritis patients was included to participate in this fluoroscopic and EMG study; only 7 patients completed the study. Kinematic evaluations took place 7 months, 1 and 2 years post-operatively. Repeated measurements ANOVA and linear mixed-effects model for longitudinal data were used to compare the differences between the follow-ups. RESULTS There are no significant changes in axial rotations between follow-up moments for the femoral component as well as the mobile insert. The insert remained mobile and followed the femoral component from 0° until approximately 60° of knee flexion. Diverging and reversed axial rotations and translations were seen during the dynamic motions. CONCLUSIONS Knee kinematics and muscle activation do not appear to change in the first 2 post-operative years. Reversed and divergent axial rotations with increasing knee flexion indicate that as soon as the congruency decreases, the femoral component is no longer forced in a certain position by the insert and moves to a self-imposed position. At lower knee flexion angles, the femoral component might be obstructed by the highly congruent insert and therefore might not be able to move freely. LEVEL OF EVIDENCE Therapeutic study, Level IV.
Collapse
Affiliation(s)
- N Wolterbeek
- Biomechanics and Imaging Group, Department of Orthopaedics, Leiden University Medical Center, Postbus 9600, J11-S, 2300 RC Leiden, The Netherlands.
| | | | | | | | | | | |
Collapse
|
11
|
Tanaka A, Nakamura E, Okamoto N, Banks SA, Mizuta H. Three-dimensional kinematics during deep-flexion kneeling in mobile-bearing total knee arthroplasty. Knee 2011; 18:412-6. [PMID: 20833548 DOI: 10.1016/j.knee.2010.08.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2010] [Revised: 08/02/2010] [Accepted: 08/16/2010] [Indexed: 02/02/2023]
Abstract
We performed an in vivo radiographic analysis of tibiofemoral and polyethylene (PE) insert motions during weight-bearing kneeling beyond 120° of flexion in one high-flexion knee arthroplasty design to determine if kinematics changed over time and if axial rotation occur between the PE insert and the tibial baseplate. Twenty knees implanted with a posterior-stabilized rotating-platform (RP) knee arthroplasty were postoperatively evaluated at 3, 6, and 12 months. The averaged flexion angles were 122°, 129°, and 131° at 3, 6, and 12 months, respectively, showing that the improvement of flexion was achieved up to 6 months. The femoral condyles translated posteriorly from extension to maximum flexion. There was a significant increase in AP translation of femoral lateral condyle in the maximum flexion kneeling between 12 months and the two other intervals (p=0.0003 at 3 months and p=0.016 at 6 months), while no differences in those of medial condyle between all intervals. Almost all rotation occurred at the surface between the tibial baseplate and the PE insert (p=0.0479 at 3 months, p=0.0008 at 6 months, and p=0.0479 at 12 months), almost no rotation occurred at the surface between the PE insert and the femoral component. There were significant increases in the amount of internal rotation angle during full flexion between the tibial component and the PE insert up to 12 months. Knees implanted with this RP knee arthroplasty design show deep-flexion knee kinematics that are consistent with the implant design intent.
Collapse
Affiliation(s)
- Azusa Tanaka
- Department of Orthopaedic and Neuro-Musculoskeletal Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | | | | | | | | |
Collapse
|