Vautrin A, Thierrin R, Wili P, Voumard B, Klingler S, Chappuis V, Varga P, Zysset P. Homogenized finite element simulations can predict the primary stability of dental implants in human jawbone. J Mech Behav Biomed Mater 2024; 158:106688. [PMID: 39153410 DOI: 10.1016/j.jmbbm.2024.106688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2024] [Revised: 07/25/2024] [Accepted: 08/11/2024] [Indexed: 08/19/2024]
Abstract
Adequate primary stability is a pre-requisite for the osseointegration and long-term success of dental implants. Primary stability depends essentially on the bone mechanical integrity at the implantation site. Clinically, a qualitative evaluation can be made on medical images, but finite element (FE) simulations can assess the primary stability of a bone-implant construct quantitatively based on high-resolution CT images. However, FE models lack experimental validation on clinically relevant bone anatomy. The aim of this study is to validate such an FE model on human jawbones. Forty-seven bone biopsies were extracted from human cadaveric jawbones. Dental implants of two sizes (Ø3.5 mm and Ø4.0 mm) were inserted and the constructs were subjected to a quasi-static bending-compression loading protocol. Those mechanical tests were replicated with sample-specific non-linear homogenized FE models. Bone was modeled with an elastoplastic constitutive law that included damage. Density-based material properties were mapped based on μCT images of the bone samples. The experimental ultimate load was better predicted by FE (R2 = 0.83) than by peri-implant bone density (R2 = 0.54). Unlike bone density, the simulations were also able to capture the effect of implant diameter. The primary stability of a dental implant in human jawbones can be predicted quantitatively with FE simulations. This method may be used for improving the design and insertion protocols of dental implants.
Collapse
Affiliation(s)
- Antoine Vautrin
- AO Research Institute Davos, Switzerland; Graduate School for Cellular and Biomedical Sciences, University of Bern, Bern, Switzerland
| | - Raphaël Thierrin
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Patrik Wili
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Benjamin Voumard
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Samuel Klingler
- School of Dental Medicine, Department of Oral Surgery and Stomatology, University of Bern, Bern, Switzerland
| | - Vivianne Chappuis
- School of Dental Medicine, Department of Oral Surgery and Stomatology, University of Bern, Bern, Switzerland
| | | | - Philippe Zysset
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| |
Collapse
|
2
|
Młynarek-Żak K, Żmudzki J. The effect of porous compliance bushings in a dental implant on the distribution of occlusal loads. Sci Rep 2024; 14:1607. [PMID: 38238380 PMCID: PMC10796672 DOI: 10.1038/s41598-024-51429-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Accepted: 04/02/2023] [Indexed: 01/22/2024] Open
Abstract
Porous dental implants are clinically used, but the mechanism of load distribution for stepped implant shaft surrounded by compliance bushings is still not known, especially for different bone conditions. The aim of the study was to assess the impact of the design of a dental implant with compliance bushings (CBs) on the occlusal load distribution during primary and secondary stability using finite element simulation (FEA), with a distinction between low and high quality cervical support under primary stability. The FEA of the oblique occlusal load transfer (250 N; 45°) was carried out for implants under variable bone conditions. The stepped shaft in the intermediate part of the dental implant was surrounded by CBs with an increasing modulus of elasticity of 2, 10 and 50 GPa. With a smaller Young's modulus of the bushings the increase of stress in the trabecular bone indicated that more bone tissue can be protected against disuse. The beneficial effect for the trabecular bone derived from the reduction of the stiffness of the bushings in relation to the loss of the implant's load bearing ability can be assessed using the FEM method.
Collapse
Affiliation(s)
- Katarzyna Młynarek-Żak
- Department of Engineering Processes Automation and Integrated Manufacturing Systems, Silesian University of Technology, Konarskiego 18a St., 44-100, Gliwice, Poland
| | - Jarosław Żmudzki
- Department of Engineering Materials and Biomaterials, Silesian University of Technology, Konarskiego 18a St., 44-100, Gliwice, Poland.
| |
Collapse
|
3
|
Wang L, Huang H, Yuan H, Yao Y, Park JH, Liu J, Geng X, Zhang K, Hollister SJ, Fan Y. In vitro fatigue behavior and in vivo osseointegration of the auxetic porous bone screw. Acta Biomater 2023; 170:185-201. [PMID: 37634835 DOI: 10.1016/j.actbio.2023.08.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 07/28/2023] [Accepted: 08/21/2023] [Indexed: 08/29/2023]
Abstract
The incidence of screw loosening, migration, and pullout caused by the insufficient screw-bone fixation stability is relatively high in clinical practice. To solve this issue, the auxetic unit-based porous bone screw (AS) has been put forward in our previous work. Its favorable auxetic effect can improve the primary screw-bone fixation stability after implantation. However, porous structure affected the fatigue behavior and in vivo longevity of bone screw. In this study, in vitro fatigue behaviors and in vivo osseointegration performance of the re-entrant unit-based titanium auxetic bone screw were studied. The tensile-tensile fatigue behaviors of AS and nonauxetic bone screw (NS) with the same porosity (51%) were compared via fatigue experiments, fracture analysis, and numerical simulation. The in vivo osseointegration of AS and NS were compared via animal experiment and biomechanical analysis. Additionally, the effects of in vivo dynamic tensile loading on the osseointegration of AS and NS were investigated and analyzed. The fatigue strength of AS was approximately 43% lower while its osseointegration performance was better than NS. Under in vivo dynamic tensile loading, the osseointegration of AS and NS both improved significantly, with the maximum increase of approximately 15%. Preferrable osseointegration of AS might compensate for the shortage of fatigue resistance, ensuring its long-term stability in vivo. Adequate auxetic effect and long-term stability of the AS was supposed to provide enough screw-bone fixation stability to overcome the shortages of the solid bone screw, developing the success of surgery and showing significant clinical application prospects in orthopedic surgery. STATEMENT OF SIGNIFICANCE: This research investigated the high-cycle fatigue behavior of re-entrant unit-based auxetic bone screw under tensile-tensile cyclic loading and its osseointegration performance, which has not been focused on in existing studies. The fatigue strength of auxetic bone screw was lower while the osseointegration was better than non-auxetic bone screw, especially under in vivo tensile loading. Favorable osseointegration of auxetic bone screw might compensate for the shortage of fatigue resistance, ensuring its long-term stability and longevity in vivo. This suggested that with adequate auxetic effect and long-term stability, the auxetic bone screw had significant application prospects in orthopedic surgery. Findings of this study will provide a theoretical guidance for design optimization and clinical application of the auxetic bone screw.
Collapse
Affiliation(s)
- Lizhen Wang
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China
| | - Huiwen Huang
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China
| | - Hao Yuan
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China
| | - Yan Yao
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China
| | - Jeong Hun Park
- Wallace H. Coulter Department of Biomedical Engineering and Center for 3D Medical Fabrication, Georgia Institute of Technology and Emory University, 313 Ferst Drive, Atlanta, GA 30332, USA
| | - Jinglong Liu
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China
| | - Xuezheng Geng
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China
| | - Kuo Zhang
- Laboratory Animal Science Center, Peking University Health Science Center, Beijing 100083, China
| | - Scott J Hollister
- Wallace H. Coulter Department of Biomedical Engineering and Center for 3D Medical Fabrication, Georgia Institute of Technology and Emory University, 313 Ferst Drive, Atlanta, GA 30332, USA
| | - Yubo Fan
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China.
| |
Collapse
|
4
|
Novel Design and Finite Element Analysis of Diamond-like Porous Implants with Low Stiffness. MATERIALS 2021; 14:ma14226918. [PMID: 34832321 PMCID: PMC8625789 DOI: 10.3390/ma14226918] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 10/19/2021] [Accepted: 10/20/2021] [Indexed: 12/16/2022]
Abstract
The purpose of this study was to design porous implants with low stiffness and evaluate their biomechanical behavior. Thus, two types of porous implants were designed (Type I: a combined structure of diamond-like porous scaffold and traditional tapered thread. Type II: a cylindrical porous scaffold filled by arrayed basic diamond-like pore units). Three implant-supported prosthesis models were constructed from Type I, Type II and commercial implants (control group) and were evaluated by finite element analysis (FEA). The stress distribution pattern of the porous implants were assessed and compared with the control group. In addition, the stiffness of the cylindrical specimens simplified from three types of implants was calculated. The Type I implant exhibited better stress distribution than the Type II implant. The maximum stress between the cortical bone–Type I implant interface was 12.9 and 19.0% lower than the other two groups. The peak stress at the cancellous bone–Type I implant interface was also reduced by 16.8 and 38.7%. Compared with the solid cylinder, the stiffness of diamond-like pore cylinders simplified from the two porous implants geometry was reduced by 61.5 to 76.1%. This construction method of porous implant can effectively lower its stiffness and optimize the stress distribution at the implant–bone interface.
Collapse
|
5
|
Ko SY, Hong JY, Lee W, Chang YY, Park KB, Yun JH. Osteoconductivity of Porous Titanium Structure on Implants in Osteoporosis. J Dent Res 2021; 100:1178-1185. [PMID: 34235985 DOI: 10.1177/00220345211023724] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
In compromised bone conditions such as osteoporosis, developments of the implant surface are necessary to secure the stability of implants. This study investigated the effect of the surface porous titanium structure (PS) on the osseointegration of implants in osteoporotic bone. Bilateral ovariectomy (OVX) was performed in 4 female beagle dogs to induce osteoporosis for 32 wk. Success of induction was based on the evaluation of bone mineral density by Hounsfield units (HU) in computed tomography images. Posterior teeth in both mandibles were extracted 1 wk after OVX, and a total of 30 implants (15 implants in each group) were placed after 32 wk of osteoporosis induction. The control group implant underwent resorbable blast media (RBM) surface treatment, whereas the test group underwent RBM surface treatment in the coronal two-thirds and a PS added to the apical 3-mm portion. HU values in the mandibular trabecular bone, lumbar, and femoral head significantly decreased 32 wk after OVX, confirming osteoporotic condition after induction. Resonance frequency analysis and removal torque test showed comparable values between the 2 groups at 4 wk after implant placement. The surface topography of the implant after removal showed hard tissue integration at the PS in the test group. Bone-to-implant contact length was greater in the apical portion of the test group, although statistical significance was not found between the groups. Interthread bone area in the apical portion of the test group showed a significant increase compared to the control group (control: 0.059 ± 0.041 mm2, test: 0.121 ± 0.060 mm2, P = 0.028) with the histological feature of bone ingrowth at the PS. The findings of the study demonstrated that the surface PS could improve osteoconductivity in the osteoporotic trabecular bone by bone ingrowth at the pore space, thereby enhancing the osseointegration and stability of the implants.
Collapse
Affiliation(s)
- S Y Ko
- Department of Periodontology, College of Dentistry and Institute of Oral Bioscience, Jeonbuk National University, Jeonju, Republic of Korea
| | - J Y Hong
- Department of Periodontology, Periodontal-Implant Clinical Research Institute, School of Dentistry, Kyung Hee University, Seoul, Republic of Korea
| | - W Lee
- Advanced Process and Materials R&D Group, Korea Institute of Industrial Technology, Incheon, Republic of Korea
| | - Y Y Chang
- Department of Dentistry, Inha International Medical Center, Incheon, Republic of Korea
| | - K B Park
- MIR Dental Hospital and MegaGen, Daegu, Republic of Korea
| | - J H Yun
- Department of Periodontology, College of Dentistry and Institute of Oral Bioscience, Jeonbuk National University, Jeonju, Republic of Korea.,Research Institute of Clinical Medicine of Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital, Jeonju, Republic of Korea
| |
Collapse
|
6
|
Michelogiannakis D, Javed F, Vastardis H. Mini-screw implant-supported pontics for the transitional management of missing permanent maxillary lateral incisors in children and adolescents: a review of currently available evidence. Eur Arch Paediatr Dent 2020; 21:285-293. [DOI: 10.1007/s40368-020-00521-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Accepted: 03/24/2020] [Indexed: 10/24/2022]
|
7
|
Li J, Jansen JA, Walboomers XF, van den Beucken JJ. Mechanical aspects of dental implants and osseointegration: A narrative review. J Mech Behav Biomed Mater 2019; 103:103574. [PMID: 32090904 DOI: 10.1016/j.jmbbm.2019.103574] [Citation(s) in RCA: 85] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2018] [Revised: 09/23/2019] [Accepted: 11/29/2019] [Indexed: 12/28/2022]
Abstract
With the need of rapid healing and long-term stability of dental implants, the existing Ti-based implant materials do not meet completely the current expectation of patients. Low elastic modulus Ti-alloys have shown superior biocompatibility and can achieve comparable or even faster bone formation in vivo at the interface of bone and the implant. Porous structured Ti alloys have shown to allow rapid bone ingrowth through their open structure and to achieve anchorage with bone tissue by increasing the bone-implant interface area. In addition to the mechanical properties of implant materials, the design of the implant body can be used to optimize load transfer and affect the ultimate results of osseointegration. The aim of this narrative review is to define the mechanical properties of dental implants, summarize the relationship between implant stability and osseointegration, discuss the effect of metallic implant mechanical properties (e.g. stiffness and porosity) on the bone response based on existing in vitro and in vivo information, and analyze load transfer through mechanical properties of the implant body. This narrative review concluded that although several studies have presented the advantages of low elastic modulus or high porosity alloys and their effect on osseointegration, further in vivo studies, especially long-term observational studies are needed to justify these novel materials as a replacement for current Ti-based implant materials.
Collapse
Affiliation(s)
- Jinmeng Li
- Department of Biomaterials, Radboudumc, P.O. Box 9101, 6500, Nijmegen, HB, the Netherlands
| | - John A Jansen
- Department of Biomaterials, Radboudumc, P.O. Box 9101, 6500, Nijmegen, HB, the Netherlands
| | - X Frank Walboomers
- Department of Biomaterials, Radboudumc, P.O. Box 9101, 6500, Nijmegen, HB, the Netherlands
| | | |
Collapse
|
8
|
Herrero‐Climent M, Falcão A, López‐Jarana P, Díaz‐Castro CM, Ríos‐Carrasco B, Ríos‐Santos JV. In vitro comparative analysis of two resonance frequency measurement devices: Osstell implant stability coefficient and Penguin resonance frequency analysis. Clin Implant Dent Relat Res 2019; 21:1124-1131. [DOI: 10.1111/cid.12868] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 10/18/2019] [Accepted: 10/23/2019] [Indexed: 02/06/2023]
Affiliation(s)
| | - Artur Falcão
- Faculty of Dentistry Oporto University (FMDUP) Porto Portugal
| | | | - Carmen M. Díaz‐Castro
- Master's Program of Periodontology and Implant Dentistry from the University of Seville Seville Spain
| | - Blanca Ríos‐Carrasco
- Master's Program of Periodontology and Implant Dentistry from the University of Seville Seville Spain
| | - José Vicente Ríos‐Santos
- Department of Periodontics and Implant Dentistry, Periodontics and Implant DentistryDental School University of Seville Seville Spain
| |
Collapse
|
9
|
Edelmann AR, Patel D, Allen RK, Gibson CJ, Best AM, Bencharit S. Retrospective analysis of porous tantalum trabecular metal-enhanced titanium dental implants. J Prosthet Dent 2018; 121:404-410. [PMID: 30396711 DOI: 10.1016/j.prosdent.2018.04.022] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Revised: 04/26/2018] [Accepted: 04/26/2018] [Indexed: 11/16/2022]
Abstract
STATEMENT OF PROBLEM The design of porous tantalum trabecular metal-enhanced titanium (TM) dental implants promises improved osseointegration, especially when grafting materials such as demineralized bone matrix are used; however, studies are lacking. PURPOSE The purpose of this retrospective study was to compare TM implants with conventional titanium alloy (Ti) implants with and without demineralized bone matrix in terms of peri-implant bone remodeling in the first year after implant loading. MATERIAL AND METHODS A chart review was used for all patients receiving Tapered Screw-Vent Ti and TM implants. Implants were placed and restored by a single provider between 2011 and 2015. Peri-implant bone remodeling was compared by using a paired t test (α=.05). RESULTS A total of 82 patients received 205 implants, 44 TM and 161 Ti implants (control). No implants failed in the TM group (survival rate of 100%), and 3 implants in total, 1 immediate, failed in the Ti groups (survival rate of 98.1%). TM implants exhibited a 0.28-mm bone gain on average, whereas the control group demonstrated 0.20 mm of marginal bone loss after the first year of implant loading. Multivariate logistic regression analysis demonstrated that the odds of having bone loss was 64% less (odds ratio: 0.36; 95% confidence interval: 0.14-0.94) in the TM group than in the Ti group after controlling for bone grafting, implant location, immediate placement, bone type, and pretreatment bone level. CONCLUSIONS TM implants exhibited less peri-implant bone loss than the control Ti implants.
Collapse
Affiliation(s)
- Alexander R Edelmann
- Resident, Department of Orthodontics, School of Dentistry, University of Texas Health Science Center, Houston, Texas
| | - Devang Patel
- Former doctoral student, Department of Prosthodontics, School of Dentistry, Virginia Commonwealth University, Richmond, Va
| | - Riley K Allen
- Research Assistant, Department of Prosthodontics, School of Dentistry, University of North Carolina, Chapel Hill, NC
| | - Chad J Gibson
- Undergraduate Research Assistant, Department of Prosthodontics, School of Dentistry, University of North Carolina, Chapel Hill, NC
| | - Al M Best
- Professor and Director of Faculty Research Development, Department of Periodontics, School of Dentistry, Virginia Commonwealth University, Richmond, Va
| | - Sompop Bencharit
- Associate Professor and Director of Digital Dentistry Technologies, Department of General Practice and Department of Oral and Maxillofacial Surgery, School of Dentistry; and Department of Biomedical Engineering, School of Engineering, Virginia Commonwealth University, Richmond, Va.
| |
Collapse
|