1
|
Feng Y, Fu R, Sun H, Wang X, Yang Y, Wen C, Hao Y, Sun Y, Li B, Li N, Yang H, Feng Q, Liu J, Liu Z, Zhang L, Liu Y. Non-invasive fractional flow reserve derived from reduced-order coronary model and machine learning prediction of stenosis flow resistance. Artif Intell Med 2024; 147:102744. [PMID: 38184351 DOI: 10.1016/j.artmed.2023.102744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Revised: 11/29/2023] [Accepted: 11/29/2023] [Indexed: 01/08/2024]
Abstract
BACKGROUND AND OBJECTIVE Recently, computational fluid dynamics enables the non-invasive calculation of fractional flow reserve (FFR) based on 3D coronary model, but it is time-consuming. Currently, machine learning technique has emerged as an efficient and reliable approach for prediction, which allows saving a lot of analysis time. This study aimed at developing a simplified FFR prediction model for rapid and accurate assessment of functional significance of stenosis. METHODS A reduced-order lumped parameter model (LPM) of coronary system and cardiovascular system was constructed for rapidly simulating coronary flow, in which a machine learning model was embedded for accurately predicting stenosis flow resistance at a given flow from anatomical features of stenosis. Importantly, the LPM was personalized in both structures and parameters according to coronary geometries from computed tomography angiography and physiological measurements such as blood pressure and cardiac output for personalized simulations of coronary pressure and flow. Coronary lesions with invasive FFR ≤ 0.80 were defined as hemodynamically significant. RESULTS A total of 91 patients (93 lesions) who underwent invasive FFR were involved in FFR derived from machine learning (FFRML) calculation. Of the 93 lesions, 27 lesions (29.0%) showed lesion-specific ischemia. The average time of FFRML simulation was about 10 min. On a per-vessel basis, the FFRML and FFR were significantly correlated (r = 0.86, p < 0.001). The diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value were 91.4%, 92.6%, 90.9%, 80.6% and 96.8%, respectively. The area under the receiver-operating characteristic curve of FFRML was 0.984. CONCLUSION In this selected cohort of patients, the FFRML improves the computational efficiency and ensures the accuracy. The favorable performance of FFRML approach greatly facilitates its potential application in detecting hemodynamically significant coronary stenosis in future routine clinical practice.
Collapse
Affiliation(s)
- Yili Feng
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China
| | - Ruisen Fu
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China
| | - Hao Sun
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China
| | - Xue Wang
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China; Department of Equipment and Materials, Tianjin First Central Hospital, Tianjin, China
| | - Yang Yang
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China
| | - Chuanqi Wen
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China
| | - Yaodong Hao
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China
| | - Yutong Sun
- Department of Cardiology, Peking University People's Hospital, Beijing, China
| | - Bao Li
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China
| | - Na Li
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China; School of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China
| | - Haisheng Yang
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China
| | - Quansheng Feng
- Department of Cardiology, The First People's Hospital of Guangshui, Hubei 432700, China
| | - Jian Liu
- Department of Cardiology, Peking University People's Hospital, Beijing, China
| | - Zhuo Liu
- Department of Radiology, Peking University People's Hospital, Beijing, China
| | - Liyuan Zhang
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China.
| | - Youjun Liu
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, China.
| |
Collapse
|