1
|
Mishra N, Patel S. Need for a Holistic Approach to Assessing Sustainable, Green, and Healthy Buildings. ENVIRONMENT & HEALTH (WASHINGTON, D.C.) 2025; 3:218-226. [PMID: 40144326 PMCID: PMC11934202 DOI: 10.1021/envhealth.4c00161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2024] [Revised: 11/14/2024] [Accepted: 11/17/2024] [Indexed: 03/28/2025]
Abstract
With the rising global population, economic development, and urbanization, building stock is bound to grow, warranting measures for optimizing their embodied and operational energy and resource consumption. Further, a building's indoor environment quality significantly affects occupants' health, productivity, and well-being since people spend almost 90% of their time indoors. Buildings safeguard occupant's well-being by shielding them from the outdoor air pollution and increasing climate extremes. However, buildings can also lead to acute and chronic exposure to pollutants trapped inside. The recent pandemic has demonstrated that indoor environments can prevent and promote airborne disease transmission depending on buildings' design and operation. The current segregated rating systems and regulations to gauge buildings' sustainability, health and safety, and energy efficiency have led to a fragmented approach hampering sustainable and healthy buildings' design, construction, and operations. This work discusses the environmental sustainability of buildings, their impacts on occupants' health and productivity, and if and how the existing global policies and frameworks regulate and promote the same. Developing a holistic and comprehensive framework is critical to ensure buildings' sustainability, occupants' health, and energy efficiency.
Collapse
Affiliation(s)
- Nishchaya
Kumar Mishra
- Department
of Civil Engineering, Indian Institute of
Technology Gandhinagar, Palaj,
Gandhinagar, Gujarat 382355, India
| | - Sameer Patel
- Department
of Civil Engineering, Indian Institute of
Technology Gandhinagar, Palaj,
Gandhinagar, Gujarat 382355, India
- Department
of Chemical Engineering, Indian Institute
of Technology Gandhinagar, Palaj,
Gandhinagar, Gujarat 382355, India
- Kiran
C. Patel Centre for Sustainable Development, Indian Institute of Technology Gandhinagar, Palaj, Gandhinagar, Gujarat 382355, India
| |
Collapse
|
2
|
Niu Y, Wang F, Luo D, Shu Z, Huang J, Zhang Y, Liu C, Qian H. Vertical transmission of infectious aerosols through building toilet drainage system: An experimental study. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2024; 343:123284. [PMID: 38163630 DOI: 10.1016/j.envpol.2023.123284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 12/23/2023] [Accepted: 12/30/2023] [Indexed: 01/03/2024]
Abstract
The building's toilet drainage system has been identified as a potential route for the transmission of SARS-CoV-2 during outbreaks. This study employed agar-fluorescein sodium semi-solid as trace particles to investigate the possibility of vertical transmission of the SARS-CoV-2 in drainage system. In both scenarios, where floor drains were all properly sealed or dried out, simulated faeces containing fluorescein sodium were flushed into the toilet bowl. Air sampling was conducted in each restroom, and differential pressure measurements at the floor drain locations were taken. The experimental results showed that when all floor drains were properly sealed, the differential pressure at each floor drain was 0. The fluorescein sodium-traced aerosol did not transmit through the drainage system to various floors, which significantly reduced the risk of infection for users through this route. However, when all floor drains dried out, toilet users above the neutral pressure layer (NPL) were at a high risk of virus infection. Due to the increasing maximum negative pressure at the floor drain above the NPL with ascending floor levels, users on each floor above the NPL faced an elevated infection risk in restrooms. Specifically, users on the top floor were exposed to infectious aerosols roughly 1.6 times that of the first floor above the NPL. Conversely, owing to the increasing maximum positive pressure at the floor drain below the NPL with descending floor levels, users below the NPL experienced a comparatively lower infection risk. This finding has important implications for understanding the vertical transmission dynamics of SARS-CoV-2 in residential or public building and can inform the development of effective control measures.
Collapse
Affiliation(s)
- Yuanyuan Niu
- School of Energy and Environment, Southeast University, Nanjing, 210096, China
| | - Fang Wang
- School of Energy and Power Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China
| | - Danting Luo
- School of Energy and Environment, Southeast University, Nanjing, 210096, China
| | - Zhiyong Shu
- School of Energy and Environment, Southeast University, Nanjing, 210096, China
| | - Jiayu Huang
- School of Energy and Environment, Southeast University, Nanjing, 210096, China
| | - Yongpeng Zhang
- School of Energy and Power Engineering, Nanjing University of Science and Technology, Nanjing, 210094, China
| | - Cong Liu
- School of Energy and Environment, Southeast University, Nanjing, 210096, China
| | - Hua Qian
- School of Energy and Environment, Southeast University, Nanjing, 210096, China.
| |
Collapse
|
3
|
Jiang X, Zhao C, Chen Y, Gao X, Zhang Q, Chen Z, Li C, Zhao X, Liu Z, Huang W, Xie W, Yue Y. Probable Evidence of Aerosol Transmission of SARS-COV-2 in a COVID-19 Outbreak of a High-Rise Building. ENVIRONMENTAL HEALTH INSIGHTS 2023; 17:11786302231188269. [PMID: 37522029 PMCID: PMC10372516 DOI: 10.1177/11786302231188269] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 06/29/2023] [Indexed: 08/01/2023]
Abstract
Although it is well established that severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can be transmitted through aerosols, the mode of long-range aerosol transmission in high-rise buildings remains unclear. In this study, we analyzed an outbreak of coronavirus disease 2019 (COVID-19) that occurred in a high-rise building in China. Our objective was to investigate the plausibility of aerosol transmission of SARS-CoV-2 by testing relevant environmental variables and measuring the dispersion of a tracer gas in the drainage system of the building. The outbreak involved 7 infected families, of which 6 were from vertically aligned flats on different floors. Environmenìtal data revealed that 3 families' bathrooms were contaminated by SARS-CoV-2. In our tracer experiment, we injected tracer gas (CO2) into the dry floor drains and into water-filled toilets in the index case' s bathroom. Our findings showed that the gas could travel through vertical pipes by the dry floor drains, but not through the water of the toilets. This indicates that dry floor drains might facilitate the transmission of viral aerosols through the sewage system. On the basis of circumstantial evidence, long-range aerosol transmission may have contributed to the community outbreak of COVID-19 in this high-rise building. The vertical transmission of diseases through aerosols in high-rise buildings demands urgent attention.
Collapse
Affiliation(s)
- Xiaoman Jiang
- Chengdu Workstation for Emerging Infectious Disease Control and Prevention, Chinese Academy of Medical Science, Chengdu, China
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Chenlu Zhao
- Chengdu Workstation for Emerging Infectious Disease Control and Prevention, Chinese Academy of Medical Science, Chengdu, China
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Yuezhu Chen
- Chengdu Workstation for Emerging Infectious Disease Control and Prevention, Chinese Academy of Medical Science, Chengdu, China
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Xufang Gao
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Qinlong Zhang
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Zhenhua Chen
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Changxiong Li
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Xiaoyan Zhao
- Chenghua Center for Disease Control and Prevention, Chengdu, China
| | - Zhijian Liu
- Chenghua Center for Disease Control and Prevention, Chengdu, China
| | - Weiwei Huang
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Wenjun Xie
- Chengdu Workstation for Emerging Infectious Disease Control and Prevention, Chinese Academy of Medical Science, Chengdu, China
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| | - Yong Yue
- Chengdu Workstation for Emerging Infectious Disease Control and Prevention, Chinese Academy of Medical Science, Chengdu, China
- Chengdu Center for Disease Control and Prevention, Chengdu, China
| |
Collapse
|
4
|
Jiang G, Liu Y, Tang S, Kitajima M, Haramoto E, Arora S, Choi PM, Jackson G, D'Aoust PM, Delatolla R, Zhang S, Guo Y, Wu J, Chen Y, Sharma E, Prosun TA, Zhao J, Kumar M, Honda R, Ahmed W, Meiman J. Moving forward with COVID-19: Future research prospects of wastewater-based epidemiology methodologies and applications. CURRENT OPINION IN ENVIRONMENTAL SCIENCE & HEALTH 2023; 33:100458. [PMID: 37034453 PMCID: PMC10065412 DOI: 10.1016/j.coesh.2023.100458] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Wastewater-based epidemiology (WBE) has been demonstrated for its great potential in tracking of coronavirus disease 2019 (COVID-19) transmission among populations despite some inherent methodological limitations. These include non-optimized sampling approaches and analytical methods; stability of viruses in sewer systems; partitioning/retention in biofilms; and the singular and inaccurate back-calculation step to predict the number of infected individuals in the community. Future research is expected to (1) standardize best practices in wastewater sampling, analysis and data reporting protocols for the sensitive and reproducible detection of viruses in wastewater; (2) understand the in-sewer viral stability and partitioning under the impacts of dynamic wastewater flow, properties, chemicals, biofilms and sediments; and (3) achieve smart wastewater surveillance with artificial intelligence and big data models. Further specific research is essential in the monitoring of other viral pathogens with pandemic potential and subcatchment applications to maximize the benefits of WBE beyond COVID-19.
Collapse
Affiliation(s)
- Guangming Jiang
- School of Civil, Mining and Environmental Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
- Illawarra Health and Medical Research Institute, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Yanchen Liu
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China
| | - Song Tang
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health (NIEH), Chinese Center for Disease Control and Prevention (China CDC), Chaoyang District, Beijing 100021, China
| | - Masaaki Kitajima
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, North 13 West 8, Kita-ku, Sapporo, Hokkaido 060-8628, Japan
| | - Eiji Haramoto
- Interdisciplinary Center for River Basin Environment, University of Yamanashi, 4-3-11 Takeda, Kofu, Yamanashi 400-8511, Japan
| | - Sudipti Arora
- Dr. B. Lal Institute of Biotechnology, 6-E, Malviya Industrial Area, Malviya Nagar, Jaipur, 302017, India
| | - Phil M Choi
- Water Unit, Health Protection Branch, Queensland Public Health and Scientific Services, Queensland Health, Australia
| | - Greg Jackson
- Water Unit, Health Protection Branch, Queensland Public Health and Scientific Services, Queensland Health, Australia
| | - Patrick M D'Aoust
- Department of Civil Engineering, University of Ottawa, Ottawa, Ontario, Canada
| | - Robert Delatolla
- Department of Civil Engineering, University of Ottawa, Ottawa, Ontario, Canada
| | - Shuxin Zhang
- School of Civil, Mining and Environmental Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Ying Guo
- School of Civil, Mining and Environmental Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Jiangping Wu
- School of Civil, Mining and Environmental Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Yan Chen
- School of Civil, Mining and Environmental Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Elipsha Sharma
- School of Civil, Mining and Environmental Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Tanjila Alam Prosun
- School of Civil, Mining and Environmental Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Jiawei Zhao
- School of Civil, Mining and Environmental Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Manish Kumar
- Sustainability Cluster, School of Engineering, University of Petroleum and Energy Studies, Dehradun, Uttarakhand, India
- Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Campus Monterey, Monterrey, 64849, Nuevo Leon, Mexico
| | - Ryo Honda
- Faculty of Geosciences and Civil Engineering, Kanazawa University, Kanazawa, Japan
| | - Warish Ahmed
- CSIRO Environment, Ecosciences Precinct, 41 Boggo Road, Dutton Park, QLD 4102, Australia
| | - Jon Meiman
- Wisconsin Department of Health Services, Madison, WI 53701, USA
| |
Collapse
|
5
|
Chang Y, Wang Y, Li W, Wei Z, Tang S, Chen R. Mechanisms, Techniques and Devices of Airborne Virus Detection: A Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:5471. [PMID: 37107752 PMCID: PMC10138381 DOI: 10.3390/ijerph20085471] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/13/2023] [Accepted: 04/03/2023] [Indexed: 05/11/2023]
Abstract
Airborne viruses, such as COVID-19, cause pandemics all over the world. Virus-containing particles produced by infected individuals are suspended in the air for extended periods, actually resulting in viral aerosols and the spread of infectious diseases. Aerosol collection and detection devices are essential for limiting the spread of airborne virus diseases. This review provides an overview of the primary mechanisms and enhancement techniques for collecting and detecting airborne viruses. Indoor virus detection strategies for scenarios with varying ventilations are also summarized based on the excellent performance of existing advanced comprehensive devices. This review provides guidance for the development of future aerosol detection devices and aids in the control of airborne transmission diseases, such as COVID-19, influenza and other airborne transmission viruses.
Collapse
Affiliation(s)
- Yuqing Chang
- Beijing Key Laboratory of Occupational Safety and Health, Institute of Urban Safety and Environmental Science, Beijing Academy of Science and Technology, Beijing 100054, China; (Y.C.); (Y.W.); (S.T.)
| | - Yuqian Wang
- Beijing Key Laboratory of Occupational Safety and Health, Institute of Urban Safety and Environmental Science, Beijing Academy of Science and Technology, Beijing 100054, China; (Y.C.); (Y.W.); (S.T.)
| | - Wen Li
- Department of Biomedical Engineering, School of Life Science, Beijing Institute of Technology, Beijing 100081, China; (W.L.); (Z.W.)
| | - Zewen Wei
- Department of Biomedical Engineering, School of Life Science, Beijing Institute of Technology, Beijing 100081, China; (W.L.); (Z.W.)
| | - Shichuan Tang
- Beijing Key Laboratory of Occupational Safety and Health, Institute of Urban Safety and Environmental Science, Beijing Academy of Science and Technology, Beijing 100054, China; (Y.C.); (Y.W.); (S.T.)
| | - Rui Chen
- Beijing Key Laboratory of Occupational Safety and Health, Institute of Urban Safety and Environmental Science, Beijing Academy of Science and Technology, Beijing 100054, China; (Y.C.); (Y.W.); (S.T.)
| |
Collapse
|